ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (805)
  • United States  (509)
  • Polymer and Materials Science  (296)
  • 2015-2019  (263)
  • 1980-1984  (542)
  • 1965-1969
  • 1960-1964
  • 1940-1944
  • 2016  (60)
  • 2015  (203)
  • 1984  (229)
  • 1982  (151)
  • 1981  (162)
  • 1926
  • Biology  (509)
  • Technology  (296)
  • Sociology
  • Geography
Collection
  • Articles  (805)
Keywords
Years
  • 2015-2019  (263)
  • 1980-1984  (542)
  • 1965-1969
  • 1960-1964
  • 1940-1944
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Hydrobiologia 112 (1984), S. 27-39 
    ISSN: 1573-5117
    Keywords: benthic macroinvertebrates ; colonization ; succession ; reservoir ; impoundment ; mainstream ; United States ; Southeast
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract The purpose of this study was to examine the colonization and succession of benthic macroinvertebrates in shallow areas (〈7 m) of Lake Anna, a new mainstream impoundment in the southeastern U.S.A. Benthic macroinvertebrates were sampled for the first three years after filling by means of artificial substrates placed on the bottom and retrieved with SCUBA. Lake Anna was well colonized by benthic macroinvertebrates during the summer season immediately after impoundment. The total density of organisms increased in each of the first three years. Major changes in the fauna occurred between the first and second years, but the changes between the second and third years were more subtle. The fauna could be divided into two distinct groups based upon the time when the organisms were most consistently abundant. The first colonizers appeared to be dependent upon the components of the former terrestrial ecosystem for food and habitat. As autochthonous factors began to regulate succession, diversity increased and the dominant species shifted to an assemblage of second colonizers. These factors included: (1) decomposition of terrestrial vegetation and detritus leaving bare substrate, (2) sedimentation, (3) improved food quality of the organic matter in the sediment because of ingestion and egestion by the organisms themselves, (4) increased plankton populations, and (5) appearance of macrophytes. As the second colonizers became firmly established in the third year, distinct patterns of spatial distribution began to appear among species with similar niches.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. iii 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. ix 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 9-18 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Physical and antimicrobial properties of a newly developed gelatin based spray-on foam bandage for use on skin wounds have been evaluated. The aqueous foam is sprayed from aerosol containers and effectively covers and washes uneven wound surfaces. The foam dries to form an adherent and stable three-dimensional matrix which diminishes evaporative water losses. The foam possesses antimicrobial activity against gram-positive, gram-negative, and fungal contaminants.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 1-7 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Tubings extruded from one batch of polyvinylchloride resin at five temperatures ranging from 110 to 205°C were tested for thrombogenicity in the saphenous vein and aorta of sheep. There was more thrombus in both the vein and aorta on tubings extruded at lower temperatures. The surface areas of renal infarction were smaller when lower temperature tubings were inserted into the aorta. Scanning electron microscopy showed that lower extrusion temperatures caused greater roughness on the tubings. This greater roughness was confirmed by roughness measurements. It is suggested that the association which has been demonstrated between roughness and thrombus formation might be due to the degree of adhesion of the thrombus to the surface rather than to differences in thrombogenicity.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 19-27 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The tensile strengths of poly(glycolic acid) (PGA) sutures immersed in buffered and unbuffered aqueous media were compared. The media used were an unbuffered physiological saline solution (pH = 5.0) and a phosphate-buffered physiological saline solution (pH = 7.4). PGA samples were immersed for various periods in each medium, and kept at 37 ± 1°C in a constant temperature oven. The tensile strengths of the specimens were tested immediately after removal from the medium. Stress-strain curves of the specimens were expressed in terms of the stress unit “tenacity,” commonly used in the study of fibrous polymers; it is an appropriate unit for materials of fibrous nature. These stress-strain curves were investigated as functions of buffering and duration of immersion. Degradation reduced the tensile strength of PGA more in the buffered saline solution than in the unbuffered. This higher rate of degradation in the buffered solution might be due to the presence of Na2HPO4, which removed the degradation products, shifted the reaction toward increased hydrolosis, and accelerated the loss of tensile strength in the PGA. A continuous decrease in the pH of the unbuffered solution supports this explanation. Tied-chain segments of macromolecules, a theory widely used in the study of mechanical strength of fibrous polymer may be the key to a comprehensive description of the degradation phenomenon of PGA.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 827-838 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Fibrous polyurethane samples were implanted in subcutaneous tissue, muscle, and as an arterial prosthesis for periods up to six months. The interface between the polymer and living tissue was studied using optical, scanning, and transmission electron microscopy. A good correlation was found between the micromorphology of the polymer-tissue interface observed in three experimental methods used. Ingrowth of tissue occurs by cell penetration into the fibrous network of the polymer implant and eventual encapsulation by connective tissue. Full details of the distribution of collagen and the cell components around the individual polymer fibers and the structure of the connective tissue are given.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 851-860 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To study the effect of fluoride on the physicochemical properties of carbonate-containing apatites, two series of fluoridated CO3 apatites with various fluoride contents were synthesized at 80°C and pH 7.4. The a-axis dimensions of these apatites decreased with the increase of both fluoride and carbonate contents. The crystallinity of the apatites showed similar patterns of variation with the degree of fluoridation irrespective of carbonate content. These patterns appear analogous to the complex pattern of the fluoridated hydroxyapatites previously reported. In contrast to this unexpected crystallinity phenomena, the apparent solubility of fluoridated CO3 apatites in acetate buffer solutions at pH 4.0 and 6.0 and 37°C decreased monotonically with increasing degree of fluoridation and approached that of fluoridated hydroxyapatites at high fluoride content. Dissolution rate of fluoridated CO3 apatite pellets at pH 4.0 also showed a simple decrease with increasing degree of fluoridation and was extremely sensitive to acid at low fluoride content.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 875-885 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Three-dimensional finite element stress analysis was used to study the effects that implant neck geometry and the tissue properties at the implant-bone interface have on the stress distribution around freestanding blade- and post-type LTI carbon and aluminum oxide dental implants. Implants having neck flares of 13° and 26° were studied. In addition, to simulate fibrous encapsulation of the implant as opposed to a direct bone apposition retention mechanism, a soft tissue interposing layer between implant and bone was also modeled. The results of the study indicate that a reduction in neck flare from 26° to 13° was a positive design change for blade- and post-type LTI carbon implants and blade-type aluminum oxide implant but not for post-type aluminum oxide implant. The results of the study indicate the presence of fibrous tissue surrounding the implants may be indicative of a failing system and may be the result of either hypophysiological stress (aluminum oxide implants) or hyperphysiological stress (LTI carbon implants).
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 741-754 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The purpose of this investigation was to determine residual monomers, the insoluble gel fraction, and singly reacted dimethacrylate monomers in heat-polymerized, auto-polymerized conventional and pourtype denture base materials. Residual monomers were determined by HPLC analysis of tetrahydrofuran extracts of denture base polymers. The gel fraction was determined by gravimetric analysis of the nonextractable portion. The pendant methacrylate groups in the gel fraction were determined by quantitative IR (infrared) spectrometry. It was demonstrated that the heat-polymerized materials had the lowest content of residual monomers. Generally, the content of pendant methacrylate groups in the gel was dependent on the initial quantity of crosslinking agent in the monomer liquids. The gel fractions of the heat-polymerized materials were larger than the quantity of reacted monomers and were also dependent on the quantity of crosslinking agent. These findings showed that some of the linear prepolymer, poly(methyl methacrylate) (PMMA), had been incorporated into the crosslinked polymer system. The gel fraction of the auto-polymerized pour-type materials corresponded to the quantity of reacted monomers, whereas the conventional auto-polymerized materials took an intermediate position between pour type materials and heat-polymerized materials in this respect.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 775-783 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The strength of bonding of dental composites to enamel was measured in shear. The compressive strength, proportional limit, elastic modulus, and tensile strength of the composites were measured for correlation with the bond strength. Conventional and microfilled composites with a range of filler concentrations were studied. The densities of the composites and their fillers and the concentrations of the fillers were determined. The mechanical properties that were most highly correlated with bond strength to enamel were proportional limit and elastic modulus. Tensile strength and filler concentration had lower correlation coefficients, and compressive strength was not correlated with bond strength. Using unfilled resins as bonding agents between the composites and enamel resulted in increased bond strength with half of the composites.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 785-798 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: It has been shown previously that supplementing plastic intrauterine devices (IUDs) with copper wire enhances the antifertility effect of the device. The use of copper intrauterine contraceptive devices, however, is currently limited to two to three years, mainly because of wire fragmentation, which was observed as early as after eight months of use. In the resulting search for a long-lasting device, two new systems of duplex wire, with gold and platinum cores electrolytically coated with copper, were devised and studied. Initially, duplex wires and controls were exposed to physiological solution. Copper dissolution rate and corrosion morphology were studied by weight-loss measurements and optical metallography. Similar systems were then surgically implanted in rat uteri for varying periods of up to 26 weeks. Electron micro-analysis of corrosion products, in addition to weight-loss measurements and metallography, was performed. The results showed that a uniform and ductile copper coating is obtainable by electroplating on gold and platinum wires. Rate of copper dissolution is similar to that of solid copper wire. No dissolution of gold and platinum in the controls or coated wires was detected by weight loss, metallography, or atomic absorption measurements. Microanalysis of the deposits and corrosion products on the wires in the uteri environment showed sulfur, chlorine, and calcium, in addition to copper. The results of this study suggest that supplementing IUDs with copper-coated gold or platinum wires may result in significant prolongation of the life span of the device by preventing uncontrolled loss of copper caused by wire fragmentation.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 799-810 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The objective of this investigation was to evaluate the in vitro and in vivo susceptibilities of a surgical cobalt-chromium-molybdenum alloy to localized corrosion. In vitro cyclic anodic polarization curves were generated for the cobalt alloy under various surface and electrolyte conditions. Surfaces of the test specimens were examined before and after each polarization experiment. In vivo analyses involved macroscopic and microscopic examinations of cobalt alloy surfaces on retrieved total hip prostheses. The electrolyte selected for the in vitro polarization study was 0.9% saline at a pH of 7.00 ± 0.05 and temperature of 37 ± 1°C in both aerated and deaerated conditions. Surface conditions for the cobalt alloys included nonpassivated and passivated treatments. Hysteresis behavior was exhibited by the passivated alloy but not by the nonpassivated alloy. According to the protection potential theory, hysteresis behavior indicates a material should be susceptible to pitting corrosion. Therefore, based on polarization curves and theory, the results of the present study indicated the cobalt alloy was susceptible to pitting corrosion when in the passivated condition but not when in the nonpassivated condition. Examination of the surfaces before and after each polarization curve revealed no evidence of pitting corrosion. Also, the examination of nonwear cobalt surfaces of total hip prostheses with implantation times up to 6 years revealed no features uniquely identified as the result of pitting corrosion. Therefore, it was hypothesized that certain conditions inherent in the electrochemical phase of this study had caused the development of hysteresis behavior for the passivated alloy, and this hysteresis behavior should not be associated with pitting corrosion as is normally taken to be the case by application of the protection potential theory. Instead, it is postulated that the hysteresis behavior exhibited by the passivated alloy is due to processes involving a breakdown of the pre-established passive film followed by a repassivation characteristic of the saline electrolyte.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 861-873 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Electode-induced bone formation was studied at six different metallic cathode materials in the rabbit medullary canal. Direct cathodic currents of 0.02 and 0.2 μA/mm2 were applied for 21 days. Quantitative differences in new bone growth were found. Platinum, cobalt-chrome (F-90) and silver had more bone relative to controls at the lower geometric current density, while stainless steel (316L) and titanium cathodes were more effective at the higher current. On average, there was a significant increase (46-48%) in new bone formation at active versus control implants for either current level. No corresponding difference in the number of vascular channels were observed in the 21 day specimens. Metal-specific differences in bone formation at control implants were also found, with platinum being most stimulatory. These observations are consistent with an interfacial electrochemical mechanism for electrode stimulated osteogenesis, which perhaps acts in concert with purely electrical and mechanical forces.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 901-910 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Microfilled composite resins have been introduced in clinical dentistry because of the difficulty in finishing conventional composite resins satisfactorily. Owing to the difference in coefficients of thermal expansion of the two resin systems, the objective of this in vitro study was to evaluate microleakage of a conventional and a microfilled composite resin. Class V cavities with butt cavosurface margins were prepared in the middle third of the facial surfaces of the crowns of 80 noncarious human premolar teeth; they were acid etched within the preparations only. Forty preparations were restored with Concise composite and forty with Silar microfilled resin. Ten teeth from each group were subjected to cyclic temperature changes between 5 and 55°C for 1000, 2500, or 5000 cycles, respectively, and ten teeth from each group were not cycled (controls). After suitable preparation, the teeth were immersed in 45Ca solution for 18 h and contact radiographs were prepared. Microleakage was scored 0-3 at both the cervical and occulusal margins of the restorations. Microleakage was significantly greater at the cervical margins than at the occlusal margins. Differences within occlusal and cervical microleakages among the two resins were not significant.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 887-899 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The clinical performance of LTI carbon, carbon-coated aluminum oxide, and uncoated aluminum oxide blade-type dental implants was studied in baboons. The objective of the study was to determine the effect that implant material elastic modulus and surface composition have on implant performance. Clinical parameters of mobility, sulcus depth, soft tissue characteristics, and radiographic appearance were used in the evaluation. The implants were placed in healed extraction sites in adult female baboons and were used as a distal abutment for a three-unit fixed gold prosthesis. The restorations were allowed to assume normal occlusal function and were left in situ for a period of two years. The radiographic and sulcus depth measurements appeared inferior for the LTI carbon implants and best for the carbon-coated aluminum oxide implants. No differences in mobility or soft tissue characteristics were noted for the three implant systems. Two implants both in the same animal - one LTI carbon and one uncoated aluminum oxide - were definite clinical failures. The results of the study indicate that an elastic modulus mismatch between implant and bone is not an a priori cause of implant failure and that the implant surface composition had little apparent effect on the clinical and radiographic performance of these implant materials.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 307-317 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Poly(2-hydroxyethyl methacrylate)-(PHEMA) has been prepared by polymerizing in presence of different types of water-soluble additives, at various amounts, which were removed by swelling in water. Mechanical properties of swollen samples have been measured and analyzed by using the classical theory of rubber elasticity. Water permeability measurements were also performed to detect the presence of micropores and to determine the type of water transport. It has been shown that it's possible, using different types and amounts of additives, to obtain a wide range of physical properties of swollen PHEMA as required for various biomedical applications.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 291-305 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The interface of alkali-poor glass ceramic implanted in femora of male Sprague-Dawley rats shows soft tissue, chondroid, osteoid, and bone in connection with the implant. The ultrastructure of the interface with soft tissue mainly exhibits a corrosion process, during which the dissolution of the crystalline phase of the glass ceramic precedes the dissolution of the glassy phase. Macrophages are involved in this process phagocytosing debris of the glassy phase and removing as well as dissolving the remainders of the glass ceramic. Under circumstances not yet fully understood, the corrosion stops, and ground substance like material is deposited, which can be, at least partially, mineralized. After the disappearance of macrophages, chondroblasts, and/or osteoblasts lay down collagen fibrils and ground substance in which matrix vesicles are discernible, representing initial foci of mineralization. Areas with bone connection display collagen fibers and deposits of apatite crystals in close relationship to the bulk glass ceramic as well as small particles mainly derived from the glassy phase of the implant, providing the micromorphological substrate for the shearing and tensile strength of the interface between glass ceramic and bone.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 335-341 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A comparison of 130 grafts done in 101 patients included 47 veins, 25 Johnson & Johnson dialdehyde-starch-tanned collagen prostheses, and 58 NCGT grafts that had been followed for a 40-month period. This study had documented the fact that in spite of frequent poor runoff, a useful result is provided by the NCGT graft apparently due in part to its built-in nonthrombogenic structure providing a cumulative patency of 73%. The patency rate was even superior with venous bypasses. Therefore, we still feel that the autogenous vein provides the most useful bypass conduit available in vascular reconstruction. In situations where a vein could not be used or was not available the NCGT graft offers an equally useful nonthrombogenic surface to maintain prolonged patency. Thus, collagen appropriately modified can provide a useful prosthesis in vascular reconstruction.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The fate of autologous pericardium when used to replace a tricuspid valve leaflet has been investigated in dogs. Changes have been studied by means of macroscopic, mechanical, histological, scanning electron microscopy, and in vitro culture techniques. In each of nine experiments the valve failed and death occurred within the first 15 post-operative days. Retraction, thickening of the cusp, fibrinous deposition and/or tissue rupture were associated with a decrease of resistance to traction tests, decrease of elasticity and increase of viscosity of the implanted tissue. The early behavior of autologous pericardium was characterized by precocious inflammatory reaction on the valve leaflets, focal disruption of the collagenous structure of the leaflets, absence of fibroblastic cell infiltration as confirmed by in vitro culture of implanted pericardium and the lack of endothelial-like cell surface at the 10th-15th postoperative day.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 343-348 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A silver staining technique was developed to demonstrate microdefects in dental restorative composites. Fine silver particles were preferentially introduced into the damaged region to provide optical contrast between the damaged and the undamaged regions. The amount of silver deposition determined with an electron probe microanalyzer, provided an indication of the extent of damage within the dental composites. Examples to demonstrate this technique were given with one clinically worn dental composite restoration and one in vitro worn composite sample.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 349-361 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Avcothane is a commercially available copolymer of polyether, polyurethane, and polydimethylsiloxane; it is used primarily in aortic balloon pumps. The pumps consist of three segments which are cemented or fused together to form the balloon. The objective of this work is to characterize the surfaces, inside and outside, of the three balloon pump sections. By using x-ray photoelectron spectroscopy (ESCA), ion scattering spectroscopy (ISS), and secondary ion mass spectrometry (SIMS) a detailed analysis of the Avcothane surfaces can be performed and comparisons between various surfaces made. Previous workers have reported ESCA and Auger electron spectroscopy (AES) measurements of Avcothane and comparisons with their results will be presented. SIMS and ISS are useful analytical tools for studying polymeric biomaterials because these techniques are usually more surface sensitive than either ESCA or AES. SIMS and ISS data indicate that a thin fluorine-rich film (probably a fluorocarbon polymer) is present on the Avcothane surface. Signals from the fluorine-rich layer are more intense from the inside of the balloon pump and the intensity generally decreases from top to bottom. The outside sections of the aortic balloon pump also show the presence of fluorine, but the signals are far less intense than from the inside. One possible explanation for the fluorine-rich layer is that a fluorine-containing compound is deposited on the balloon pump during molding and preparation. Another possibility is that the layer is deposited during preparation of the Avcothane itself, but is essentially removed from the outside during sterilization.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: ABA-type block copolymers composed of 2-hydroxyethyl methacrylate (HEMA), a hydrophilic monomer, and styrene (St), a hydrophobic monomer, were synthesized by the coupling reaction of telechelic oligomers used as prepolymers. These block copolymers may be represented as microphase-separated structures. It is therefore possible to change the balance between hydrophilicity and hydrophobicity in the level of an assembled order of macromolecules. In response to the relative composition of the copolymers, three typical morphological patterns were observed in electron microscopic photographs: dispersed domains of continuous St chains in the region of HEMA chains, alternate HEMA and St lamellae and finally, dispersed phases of continuous HEMA chains in the region of St chains. The effect of the hydrophilic and hydrophobic microdomains of the copolymers on the mode of interaction between polymers and platelets was studied by the microsphere column method. In the case of homopolymers and random copolymers, a significant degree of platelet adhesion and aggregation was observed. However, the degree of platelet adhesion and deformation was suppressed on the surfaces of the block copolymers containing 0.608 and 0.347 mole fractions of HEMA whose microdomains were hydrophilic-hydrophobic lamellae and isolated hydrophilic islands in hydrophobic areas, respectively. These results show that the microphase-separated structures were antithrombogenic and prevented platelet adhesion and deformation. On the basis of the results obtained, the interaction between platelets and polymer surfaces was described in terms of the effect of hydrophilic and hydrophobic microdomains.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 433-435 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 425-432 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The molecular and macroscopic changes occurring during the polymerization of poly(methyl methacrylate) (PMMA) bone cement have been investigated. Electron paramagnetic resonance (EPR) spectroscopy was used to monitor free-radical generation and this was compared to temperature changes occurring in the cement for various ratios of polymer powder to liquid monomer (P/L ratio) used in the sample preparation. Both the concentration and the characteristic growth time of the free radicals associated with the polymerization of the bone cement depended on the P/L ratio used. Larger P/L ratio resulted in shorter characteristic growth time for the free radicals as well as a shorter time for the occurrence of the peak sample temperature. Smaller P/L ratios gave smaller maximum concentrations of free radicals and larger peak temperatures. These results are explained on the basis of (1) more initiators present at higher P/L ratios resulting in faster polymerization and (2) less initiators and more monomers present at smaller P/L ratios resulting in fewer radicals but more exothermic reactions. The free radicals present in the bone cement due to the manufacturer's sterilization process were found to be proportional to the fraction of powder used in the preparation, indicating negligible monomer loss during sample mixing.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. v 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 413-425 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A complete study of the static and dynamic strength of complete maxillary dentures was undertaken. First, the denture base material was investigated in its various forms from the point of view of tension, creep, relaxation, fatigue, and the effect of a corrosive environment. Complete dentures were tested under static compression, and the distribution of stresses along the midline of the upper dentures was determined by means of strain rosettes and by reciprocating compression, the determination of their fatigue strength. The results were found to conform with experience as far as lifetime of complete dentures is concerned.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 435-462 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Many authors have examined the mechanical properties of bone cement and the various factors that affect its mechanical behavior. This article presents a comprehensive survey on the reported mechanical properties of bone cement. Variables that influence the mechanical properties, such as handling characteristics, strain rate, loading modes, additives, porosity, blood inclusion, in vivo environment, temperature, etc. have also been reviewed. The importance of specifying these variables in reporting test results on the mechanical properties of bone cement is pointed out. Previous attempts to improve the mechanical properties of bone cement are also summarized. Future research areas important for fully characterizing the physical properties of PMMA are also suggested.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 137-146 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Randomly cross-linked copolymers of 2-hydroxyethyl-methacrylate (HEMA) and methyl-methacrylate (MMA) have been prepared and studied in the dry and swollen state. Tensile and indentation tests indicate that by changing the composition of copolymers, it is possible to obtain materials with a wide range of mechanical properties and corresponding glass transition temperatures. Water diffusion coefficients in sorption and desorption experiments have been calculated and compared.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 565-575 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The A.D.A. acute systemic test for type II, class 11 materials defines compliance on the basis of fewer than 50% mortality at 2 weeks. Histopathologic criteria were developed from pilot study data to evaluate the effects of these materials. In this double blind study, the frequency of histopathological changes in lung, liver, small intestine, and kidney were rated at 2 and 5 weeks, for six dental crown and bridge alloys ranging from 44% to 97% (Au, Pt, and Pd). Two positive 360 mg/kg and 1 g/kg of cadmium and two negative, a blank capsule and untreated control groups were used. There was significant difference (chi square test, X2 = 0.95) between the positive and negative controls at 2 and 5 weeks. The lung, liver, kidney showed the highest level of histopathological changes. Significant changes occurred in the four tissues for all alloys at two and five weeks. At five weeks, alloys with a lower noble metal content (44-62%, Au, Pd, and Pt) elicited significant chronic changes, while higher noble metal content (78-97%) showed healing and no significant difference from the negative controls. Applying histopathologic criteria and statistical parameters independent examiners can examine experimental animals and arrive at conclusive and reproducible results.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 605-610 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 591-603 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Proteolytic enzymes have been employed in an in vitro model to simulate the in vivo degradation of a synthetic poly(amino acid) hydrogel. Trypsin and collagenase had no effect on crosslinked poly(2-hydroxyethyl-L-glutamine) but pronase and papain dissolved the hydrogel. The initial effect of papain was to decrease the effective cross-link density without producing soluble material. This effect was similar to that observed previously in vivo. Analysis of the papain digestion products showed that oligomers of degree of polymerization 4-9 were the chief products. The rate at which oligomers were formed increased with increasing crosslink density. This phenomenon was attributed to hydrophobic effects.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 611-614 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Although dogs have been used widely to study the healing of large caliber synthetic grafts, hypercoagulability probably makes the dog a poor model for studies of small caliber vascular prostheses. The baboon's coagulation system is similar to man's, but large caliber baboon grafts were reported to endothelialize rapidly. In this study the healing pattern of 4mm internal diameter Dacron carotid interpositon grafts in baboons was determined using specimens harvested at time points between 2 weeks and 18 months post-implantation and examined with light and scanning electron microscopy. The luminal surface of baboon grafts in the acute healing phase (〈1 month) was comparable to that reported in the literature for dogs. Baboon grafts did not completely endothelialize until 10-12 weeks post-implantation. For work with small caliber vascular protheses, the dog appears to have no advantage over the baboon as an animal model on the basis of graft healing.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 655-661 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Cellulose oxidized with periodate (OC) has been shown to be a biocompatible, biodegradable matrix suitable for immobilization and sustained release of drugs. In the present work, insulin was immobilized on the OC-matrix and the release profile in vivo and in vitro was examined. The hormone is bound to the matrix by Schiff's bond formation and is released by hydrolysis of this bond as well by degradation of the OC-matrix. The release can be sustained over longer periods by reducing the Schiff's base with NaBH4. The insulin depots could be conveniently injected as suspensions and are able to maintain glucose levels in diabetized rabbits at normal values over several days.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 395-401 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The macrophage plays a pivotal role in both wound healing and cellular response to implants, including percutaneous devices. Within twenty-four hours macrophages were found in close contact with the implant surface. Eventually fibroplasts and connective tissue proliferate, and finally the implant will be encapsulated. The presence of macrophages is essential for the activation of collagen synthesis by fibroplasts. Implant shape and surface can profoundly affect macrophage behavior. At rough implant surfaces macrophages with giant cells are present for many months with the possibility of chronic granulomatous reactions. Superior tissue compatibility should be associated with smooth, well contoured implants with no acute angles.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 427-434 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A Ni-45 wt % Ti (Ni-50 at % Ti) alloy was cast into molds of magnesia and silica investments by use of a dental argon-arc pressure casting machine with a copper crucible. The castings exhibited shape memory properties. The shape recovery process was sharper in the specimens cast in magnesia investment molds than in those cast in silica (phosphate-bonded) investment molds. The latter casting had a hard region of the periphery, suggesting that shape recovery process may be affected by reaction of molten metal with silica. Furthermore, the alloy possessed the adequate mechanical properties for consideration as crown-and-bridge prostheses.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The release of corrosion products by implants has become a matter of concern. Using a microsphere model, the release of chromium, cobalt, and nickel, secondary to implantation of various surface area exposures of F-75, a cast cobalt-chromium alloy, was studied over a 30 day period in the rat. Dose related elevations were observed in the serum concentration of chromium and cobalt but not of nickel, with the maxima being achieved at 3 days after metal implantation followed by declines in concentration. The chromium elevation, approximately twelvefold for a surface area to body weight (SA/BW) ratio of 300 x is similar to that previously reported in patients receiving total hip replacement arthoplasties. However, the cobalt elevation, twentyfold for a SA/BW ratio of 300 x, has not been previously observed. These serum concentration changes are as yet unexplained, but are probably not due to fibrous capsule maturation or alloy repassivation.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 547-559 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An in situ immunoradiometric assay was devised to quantitate human fibrinogen deposited on hemodialysis membrane, Cuprophane, from in vitro exposure to fibrinogen solution and from ex vivo extracorporally clinical use. The method requires a monospecific 125I-labeled antifibrinogen-IgG purified by DEAE chromatography and immunoadsorption. The labeled antifibrinogen IgG was shown to react specifically with fibrinogen adsorbed and immobilized (by glutaraldehyde) on Cuprophane. Other plasma proteins such as human albumin, IgG, or α-thrombin, adsorbed singly or coadsorbed with fibrinogen on the surface did not seem to affect the fibrinogen-antifibrinogen reaction. The presence of blood cells such as platelets and granulocytes with fibrinogen on Cuprophane reduced only slightly the uptake of 125I-antifibrinogen-IgG. The examination of fibrinogen-fibrin deposition on clinically used Cuprophane by this technique and by autoradiography of the same material following 125I-antifibrinogen-IgG conjugation indicated that the deposition of fibrinogen was heavy and heterogeneous. We concluded that this in situ method may be useful to monitor fibrinogen-fibrin deposition and adsorption of other plasma proteins that occur under in vitro, ex vivo, and in vivo conditions.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 601-607 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study was undertaken to examine the effectiveness of a commercially available n-butyl-2-cyanoacrylate (Histoacryl blueTri-Hawk International, 1570 Barré, Montréal, H4L 4M6 Quebec.) as a local treatment for cutaneous ulcers. Two ulcers, approximately 0.5 cm2 each, were made on the backs of 30 hamsters. The right side was covered with a thin film of tissue adhesive, while the left side was left untreated as a control. Animals were sacrificed at various times post-operatively, the tissue excised, processed, and examined with the light microscope. Results showed that cyanoacrylate decreased the inflammatory exudate early in the experiment, and epithelial migration occurred slightly earlier in experimental tissue. Scab formation was absent in experimental sites until the layer of adhesive was lost. After 2 days, healing was comparable in both experimental and control, and the sites were indistinguishable histologically at day 5.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 895-909 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An alternative to the usual technique of preclotting porous textile vascular prostheses prior to surgical implantation is to render them impermeable to blood by impregnation with a cross-linked albumin filler matrix. This material subsequently becomes the foundation for cellular development. The compatibility of such impregnated fabrics with newly formed endothelial cells has been evaluated by an in vitro organotypic culture method. This technique enables the characterization and numeration of cells that develop on blood contact surfaces and enables determination of their rate of development. Woven, knitted, and velour fabrics were evaluated folllowing coating with albumin and either storage in Tyrode solution or 40% ethanol or desiccation by critical point drying. Preclotted cardiovascular repair fabrics prepared according to conventional surgical protocol served as controls. The identification of the newly formed cells was confirmed histologically. The most extensive and rapid cellular development was observed on the woven fabric and is believed may have resulted from the smoother surface topography of this substrate. Good cellular development was noted particularly on fabrics which had been stored in Tyrode solution. Ethanol had a deleterious effect on the apparent compatibility.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 695-705 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Human prothrombin in Tyrode's solution, in mock plasma (albumin, fibrinogen, and IgG mixture), and in citrated plasma adsorbs to Cuprophane, polyvinylchloride, and polyacrylonitrile surfaces. The adsorption of prothrombin is maximal in Tyrode's solution and minimal in plasma. The surface concentrations of prothrombin are highest on polyacrylonitrile, second on polyvinylchloride, and lowest on Cuprophane at all prothrombin concentrations tested in the bulk solution. Qualitative tests show that prothrombin adsorbed to polyvinylchloride can be activated by Taipan snake venom to generate thrombin that clots fibrinogen. However, more quantitative tests indicate that only part of the adsorbed prothrombin on all three materials can be activated to form thrombin exhibiting amidolytic activity. The partial reactivity of adsorbed prothrombin is further confirmed by release of 125I-peptide from surface bound 125I-prothrombin after treatment with Australian Taipan snake venom. Prothrombin bound to Cuprophane seems to promote granulocyte adhesion, but has no effect on platelet adhesion.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 727-736 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Bovine pericardial tissue and tissue-derived bioprosthesis fixed in glutaraldehyde and stored in either glutaraldehyde or formaldehyde can induce cytotoxic reactions even after prolonged washing due to the slow leaching of the chemicals used for crosslinking and sterilizing. Sequential rinsing for up to 60 min was still not sufficient to eliminate cytotoxic effects. On the other hand, satisfactory results were obtained when cardiac valves made from glutaraldehyde fixed pericardium were stored in a solution containing 0.02% of propyl-hydroxy-benzoate and 0.18% methyl-hydroxy-benzoate. The valves stored in this solution and rinsed three times for 1 min in normal saline showed few signs of residual cytotoxicity. Rinsing in a solution containing glycine was partially effective in neutralizing the cytotoxic effect, and this or similar approaches offer good possibilities. The use of Chang cells grown in culture provides an excellent quantitative assay for the assessment of residual cytotoxicity and for evaluating the host response to different methods of fixation, storage, and rinsing of tissue derived bioprosthesis.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 771-779 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Few in vitro systems for testing dental restorative materials have taken into account the protection afforded by the residual dentine in vivo. In turn opinions differ as to whether an increase in residual dentine thickness increases this protection. In this study an increase in the depth of dentine powder beneath zinc oxide eugenol (ZOE) reduced its toxicity, while this was not the case with the glass ionomer cement. Compaction of the powder had no effect, suggesting that protection was due to binding of the toxicant to the dentine rather than it acting as a physical barrier. Protein was shown to be very important in moderating the cytotoxicity of ZOE. These results suggest that in vivo the irritancy of some materials may be related to the depth of residual dentine but not others. The effect of exposure period and volume of these materials on their cytotoxicity was also investigated. Increasing the volume of ZOE while retaining the same surface area increased the toxicity of ZOE, while with the glass ionomer it had no effect.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 785-785 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 769-780 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Equipment is described which enables the determination of the creep behavior of small specimens of dental amalgam under tensile stresses. The apparatus has been used to measure the creep strain of both low and high copper dental amalgams at 34°C, in the stress range 9.4 to 38.8 MNm-2, for time periods of up to 24 h. Significant differences were found in the controlling creep mechanisms for the various amalgam types. Conventional amalgam displayed classical steady-state creep. The high copper amalgams, however, were best represented by transient creep equations implying interference to the motion of dislocations by the presence of hardening precipitates.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 881-894 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The macromolecular properties of 17 virgin commercial arterial prostheses and a series of explanted prostheses, both manufactured from poly(ethylene terephthalate) (PET) yarns, have been studied by gel permeation chromatography (GPC) and by differential scanning calorimetry (DSC). Only small differences were found between the average molecular weights and the degree of crystallinity of the unused reference grafts. A broadening of the DSC curves was observed for the prostheses containing texturized yarns compared with those made solely from flat, untexturized yarns. This broadening may be due to greater heterogeneity of the crystal sizes caused by the texturizing process and to the use of two or more different yarns with dissimilar thermal histories in the same prosthesis. Average molecular weights of the explant series were significantly lower than those of the corresponding reference grafts but almost time independent. The polydispersity index and the degree of crystallinity of the explants remained constant as a function of time. These results are discussed in regard to others available in the literature.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A cage implant system was utilized to quantitatively and qualitatively characterize in vivo leukocyte interactions with cast Biomer. Scanning electron microscopy (SEM) in conjunction with cytochemical staining procedures were used to investigate the cellular events at the leukocyte/Biomer interface as well as in the inflammatory exudate over a 21-day implantation period. SEM was used to characterize leukocyte morphology on the Biomer surface and the cytochemical stains were used to differentially count leukocytes and to demonstrate intracellular alkaline and acid phosphatase activity. The results showed that the population density of leukocytes on the Biomer surface diminished with implantation time. The population density of multinucleated foreign body giant cells remained constant with time, while the numbers of nuclei per giant cell increased. The differential analysis revealed that macrophages preferentially adhered to the Biomer surface compared to other leukocytes in the exudate. The phagocytic capability of all adherent leukocytes, including giant cells, decreased with time and this corresponded to changes in leukocyte morphology observed with SEM.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 1017-1030 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Bioreactive-glass-coated hip prostheses were implanted in dogs for periods of time ranging from 3 to 17 months. The prostheses were tailor-made for each animal through the use of standard radiographs. However, such a procedure does not necessarily yield a close apposition between the glass layer and bone. As a result, the initial stability of the component can be lost before bone bonding is established. Secondary to this phenomenon, the micromotion can lead to a continuous disruption of the top film on the glass despite the evidence of various reaction layers on the glass surface.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 829-833 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A previous study of the effect of final Hg content on the static creep of a single-composition high-Cu amalgam alloy showed a sudden increase or jump in creep at a specific Hg content, and the presence of the Sn—Hg phase (γ2) at final Hg contents subsequent to this creep jump. This observation is consistent with the less-than-optimum clinical performance reported for this alloy. A repetition of these tests conducted on test specimens 3 months and 6 months of age showed the creep jump to shift to higher Hg contents. However, even at 6 months of age, the final Hg content to be expected in clinical restorations was still positioned after the initiation of the creep jump where a small amount of γ2 is known to be present.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 843-851 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Conventional finishing and polishing techniques used to prepare Vitallium subperiosteal dental implant castings were found to produce low energy surfaces as measured by critical surface tension. Standard metallographic preparation gave slightly higher values. Glow discharge cleaning of both types of polished surface gave much higher critical surface tension values. This suggests the presence of an organic film after surface polishing of the implant which may later affect tissue reaction, in particular attachment, as has been noticed in related animal studies.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 853-865 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Bone remodeling due to stress-shielding has been studied using a model system consisting of metal-polymer laminated fixation plates securely fixed to canine femurs. The plate stiffness was controlled by varying the ratio of metal facing to polymer core thickness in the laminate design while secure fixation to bone was achieved by providing a porous bone interfacing surface for the ingrowth of bone from the periosteal surface. Observations of laterally and medially placed plates indicated resorption in the area of the periosteal and endosteal bone surfaces respectively, for the higher stiffness composite plates used. The results indicate that plate stiffness greater than approximately 70 GPa (axial) and 6 N m2 (flexural) will result in extensive bone remodeling in the canine femur after a six month implantation period.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 867-878 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Mechanisms of corrosion at the areas of contact between screw heads and plate holes were investigated using electrochemical potential recording techniques. Static crevice corrosion was studied with plates and screws in isotonic and hypertonic saline solutions (0.9 to 7.2% NaCl). Fretting corrosion was studied in vitro with plates screwed to tubular bone analogs which were subjected to cyclic axial loads, and was studied in vivo with plates screwed on the tibia of sheep. Static tests showed that crevice corrosion does not occur in isotonic saline for periods up to one year, but can occur in hypertonic saline solutions. Dynamic loading tests demonstrated immediate potential changes which were related to the magnitude of the applied load, indicating fretting corrosion due to motion between screw head and plate, both in vitro and in vivo. A mechanism for screw-plate relative motion is proposed. It is hypothesized that corrosion seen in clinically retrieved implants due to fretting corrosion which predisposes the contact area to crevice corrosion attack.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 879-887 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A three-dimensional finite element analysis (FEA) has been used to determine the effect of implant elastic modulus on stresses in tissues around LTI carbon and aluminium oxide dental implants. The finite element model was constructed to represent a baboon mandible containing a blade type dental implant. A three unit fixed bridge was modeled connecting the dental implant to a natural molar. The results of the study indicate that stress levels of approximately a factor of 3 lower in the crestal region can be expected for aluminum oxide implants when compared to the LTI carbon implants. It was also observed that the use of LTI carbon and aluminium oxide dental implants as an abutment in a fixed bridge results in a reduction of stresses in tissues around the natural tooth when compared to normal physiological stress levels.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Judging biocompatibility of materials with blood includes assessment of hemolysis resulting from flow in contact with those materials. Such hemolysis is influenced in part by the surface roughness and specific hydrodynamic features of the device used. Using a rotating-disk device, with polyethylene disks and human blood, it was shown that roughness under 4 μm has negligible effect and that hemolysis increases sharply for roughness above about 11 μm. Gross roughness (65 μm) causes qualitatively different hemolysis kinetics but not as severe hemolysis as extrapolated from low-roughness data. In the disk geometry, the corner is a key region which generates high hemolysis and thus minor alterations cause hemolytic variations which may tend to obscure materials influences. A series of corner-beveled polycarbonate disks were tested in comparison with the normal square corner and were found always to cause greater hemolysis. Tapering the bevel inward, so the taper angle was on the order of 2°-4°, reduced hemolysis relative to the 45° bevel but still was more hemolytic than the flat disk. Evidence suggests that glassy plastics can be machined with more reproducibility at the corners than plastics above their Tg such as polyethylene. General device design problems regarding hemolysis are discussed.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 11-16 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The poly(tetra peptide), H- (L·Val1-L·Pro2-Gly3-Gly4)n-L·Val-OMe, which is a recurring sequence in tropoelastin the precursor protein of the elastic fiber, has been irradiation crosslinked to produce an elastomeric material with limited strength. When a material such as a Dacron fabric is impregnated by the coacervate phase of the poly(tetra peptide) prior to irradiation crosslinking at 50 Mrad, the crosslinked product exhibits stress-strain curves with good elastomeric properties and high strength. In addition to the stress-strain curves, the material is characterized by scanning electron microscopy.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 31-38 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The biocompatibility and high gas transfer characteristics of gas-permeable membranes have led to their use for total and supportive cardiopulmonary bypass. The gas transfer rates, particularly of oxygen, have previously been measured with sophisticated apparatus and this has restricted accurate measurements to a few laboratories. A simple chemical technique for measuring the oxygen permeability of synthetic membranes is described, in which sodium hydrosulfite is used to provide the highest possible oxygen gradient and the volume of oxygen crossing the membrane is measured volumetrically. Results agreed with those obtained with orthodox apparatus and replacement of the reducing agent with blood gave much lower oxygen transfer rates demonstrating the rheological influences of the blood upon oxygen transfer.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A series of heparinized hydrophilic polymers (H-RSD) composed of a hydrophobic element, a nonionic hydrophilic element, a cationic element and ionically bound heparin was synthesized. The permeability of the H-RSD polymers with various chemical compositions and water contents was investigated. From the studies on the permeability, it has been found that in order to maintain good permeability after heparinization, the nonionic hydrophilic element is necessary. In addition, the microencapsulation of activated charcoal granules using a H-RSD polymer with a similar permeability to that of Cuprophan was examined. In vitro adsorption studies and in vivo direct hemoperfusion studies on the activated charcoal microencapsulated with the H-RSD polymer, show that the H-RSD coating prevents clot formation without loss of the absorption power of the activated charcoal.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 39-49 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Phosphorus-31 nuclear magnetic resonance spectroscopy of phosphoric acid solutions containing zinc and aluminium indicates that zinc forms simple salts in solution, whereas aluminium forms a number of complexes, some of which are polymeric. The formation of the aluminophosphoric acid complexes controls the gelation and strengthening of the dental silicate cement and prevents the formation of crystalline zinc phosphate in the zinc phosphate cement.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 51-61 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Acute and chronic studies were performed in the canine model to evaluate a new topical hemostatic agent in terms of initial hemostatic capability and tissue/material interaction during the healing process. IP760, a porous amylose succinate material, was applied to large spenic surface wounds in six acute and twelve chronic animals. Microfibrillar collagen (Avitene) was used in twelve chronic animals for comparison. While the hemostatic capabilities of the two agents were comparable, marked differences were noted in the healing response. In the IP760-treated wound sites the acute inflammatory response, granulation tissue infiltration with fibrosis and healing occurred earlier and in a more homogeneous manner than in the Avitene-treated wound sites. Healing of the IP760-treated wounds occurred concomitantly with the development of granulation tissue and fibrosis and the rapid resorption of the IP760.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 87-91 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 63-79 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Phase relationships in cast Co—Cr surgical implant alloys, heat treated at temperatures from 1180 to 1300°C, are reported. Interdendritic material was identified by selected area diffraction as a quaternary near eutectic mixture between sigma phase, M23C6, M7C3, and fcc Co. Incipient melting and subsequent resolidification of this near-eutectic mixture accounts for observations of behavior at temperatures above 1235°C. At temperatures just below its melting point the interdendritic material initially breaks down to M23C6, which subsequently dissolves in the Co matrix.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In addition to Sn-rich corrosion products found in conventional amalgams, Cu-rich amalgams also form Cu-containing corrosion products. The nature of these Cu-rich products was investigated by immersion of samples of 13 Cu-rich amalgam systems in Ringer's solution for prolonged periods. SEM/EDS and x-ray diffraction studies were used to identify the compounds formed and their morphology. Two products were identified: Cu2O, a red product, and CuCl2·3Cu(OH)2, a green product.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 93-94 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 95-104 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The biological compatibility of polypyrrolidone was investigated using subcutaneous implantation in rats. Acute (10 days) and chronic (360 days after implantation) tissue reaction was characterized numerically and compared with poly(2-hydroxyethyl methacrylate), used in the Drug Control Research Institute in Prague as a standard in the evaluation of polymers, for which good tolerance in the clinical practice has been demonstrated. Surface changes in the polymer were evaluated by using a scanning electron microscope.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 105-115 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Management of the chronically instrumented animal is improved by enclosing the terminations of catheters and transducer wires in a subcutaneous nylon velour pouch. Six or more days after implantation, an opening is made into the pouch by removing a portion of the overlying skin; subsequent healing processes provide a satisfactory bond. Thereafter the leads can be extracted and replaced without need for anesthesia or dissection. Results in 35 animals (26 dogs and 9 monkeys) for intervals up to four months showed fibrous encapsulation was complete in 28 and partial in 7, with no mortality or significant morbidity attributable solely to the presence of the pouch. Gross and microscopic tissue examination indicated a localized foreign body reaction in response to the nylon fibers. The technique is especially useful in experimental protocols for which continuous restraint is undesirable, such as the chronically instrumented primate periodically exposed to environmental stress.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 125-134 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The corrosion of the pure metals aluminium, cobalt, copper, chromium, molybdenum, nickel, and titanium and of a cobalt-chromium molybdenum casting alloy has been studied in buffered saline with and without the presence of the proteins serum albumin and fibrinogen. The corrosion of aluminium and titanium was unaffected by the protein. The corrosion rates of chromium and nickel showed a slight increase, while cobalt and copper dissolved to a very much greater extent in the presence of protein. However, with molybdenum the corrosion was inhibited by protein.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 117-124 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The pH effect on the hydrolytic degradation of Polyglactin 910 copolymer was studied in terms of the tensile properties of the suture specimens. The use of a cord/yarn grip, newly designed specifically for fibrous materials, eliminated the grip-induced failure. Different degrees of hydrolytic degradation of this copolymer at 3 different pH levels were observed. The suture specimens exhibited the best retentions of breaking strength at the physiological pH of 7.44, while the specimens at pH = 10.09 showed the fastest loss of breaking strength. Thus, a maximum retention of tensile properties occurred around the pH level of 7.0, whereas smaller percentages of retention of tensile properties were observed at both acidic and strong alkaline solutions. This synthetic absorbable suture material exhibits the basic characteristic of hydrolysis which is catalyzed by both acid and base.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 135-144 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The setting reaction of six dental materials has been studied by using a water dilatometer at 25° and 37°C. Where there is no water absorption during the test, the method gives reproducible values of the setting shrinkage and at the same time shows a clear physical picture of the entire setting process. This method is suitable for adaptation as a specification test for setting shrinkage and has good potential for being used as a supplementary or substitute test for initial and final set times.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 181-194 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study pertains to the development of poly(α-amino acid) membranes which have potential as biomaterials. Copoly(L-alanine, L-methionine) membranes have been subjected to oxidation which produced a hydrophilic structure allowing the improvement of oxygen permeability. L-Methionine residues in the copolymers were converted to methionine sulfoxide and/or sulfone groups by action of hydrogen peroxide in various reaction compositions. Water absorption, permeability to oxygen dissolved in water, and tensile strength of the modified membranes were changed with the extent of oxidation. The water absorption was found to increase with oxidation time from 10 to 300%. The oxidation time dependency on the oxygen permeability coincided with the increase in the water absorption. The permeability coefficients of oxidized membranes were of the order of 10-9 cm3 (STP) cm/cm2 s cm Hg, while those of unoxidized membranes were approximately 10-11. As expected, the tensile strengths of oxidized membranes were smaller than those of unoxidized ones. In addition, the effect of L-alanine and L-methionine residue composition on the membrane properties is discussed.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 209-218 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The change in aggregability of the platelets stored in the storage tube fabricated from a newly developed heparinized hydrophilic polymer (H-RSD) has been studied in comparison with plasticized poly(vinyl chloride) (PVC) which is widely used for blood bags. Rabbit blood was directly withdrawn into the storage tube containing an anticoagulant from the carotid. Then the tube was mechanically sealed with screw cocks and centrifugated to prepare platelet-rich plasma (PRP) in the tube and again mechanically clamped to separate the PRP from the residual precipitate. The PRP was stored in situ in the storage tube at room temperature under agitation. During storage, the change in the aggregability of the PRP induced by adenosine diphosphate (ADP) was studied and the morphological change in the platelets adhered onto the inner surface of the storage tube was observed by scanning electron microscopy. In the H-RSD tube, the aggregability was maintained during two-day storage, while in the PVC tube, the aggregability was completely lost after one-day storage. The scanning electron microscopic studies demonstrated that the reduction in the aggregability of the stored platelets is closely correlated with the morphological deformation of the platelets adhered onto the surface of the storage tube.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 195-207 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We have demonstrated that an established hamster cell line (NIL 8 M-2) will adhere to the bioceramic bioglass. The rate at which the NIL 8 M-2 cells assume a spread morphology on bioglass is density dependent and the morphology displayed by NIL 8 M-2 cells attached to bioglass is much more elongated than that displayed by NIL 8 M-2 cells attached to nonreactive glass. Precoating the bioglass with the plasma form of human fibronectin significantly reduces the density dependent nature of cell spreading. Coating the bioglass with fibronectin also reduces the time required for cell spreading and changes the morphology of the attached cells from an elongated to an extremely flattened shape. Our work raises the possibility that bone-implant adhesion might be improved by introducing molecules relevant to cell-substrate attachment into the biomaterial prior to implantation.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 571-584 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Twenty-four rectangular metal plates were fabricated with surface regions in three different pore size ranges (5-20 μm, 20-50 μm, 50-200 μm). The plates were implanted into the dorsal subcutaneous tissue of 12 adult mongrel dogs for periods of 4, 8, 12, and 16 weeks. After animal sacrifice, the fibrous tissue which adhered to the porous-surfaced regions of each plate was mechanically peeled off to give an indication of the strength of tissue attachment. The tissue was examined by both transmitted light and scanning electron microscopy. At each time period, the tissue that contacted the porous regions was found to be collagenized fibroconnective tissue. The mechanical tests indicated an increasing strength of tissue attachment with increasing implantation time and pore size range. The largest pore size range of approximately 50-200 μm produced a mean peel strength of attachment of 27.5 g/mm at the 16-week period.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To assess abrasive wear of mechanical valve prostheses containing pyrolytic carbon components, we recovered at necropsy or surgery and analyzed by scanning electron microscopy and surface profilometry eight prostheses. Seven were implanted for 30-85 (mean 50 months). Valves included DeBakey aortic (2), DeBakey mitral (1), Beall mitral (2), Bjork-Shiley aortic (1), Cooley-Cutter mitral (1), and Lillehei-Kaster (L-K) tricuspid (1). All carbon occluders had undetectable wear. Carbon cage struts had a superficial burnish. Metallic struts had insignificant wear marks. In contrast, a Teflon Beall Model 104 valve implanted for 34 days and similarly analyzed had considerable material loss from the cage struts. This study suggests that clinically important abrasive wear will not be a late complication of cardiac valve replacement with pyrolytic carbon prostheses.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 961-968 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Polyurethanes are finding increasing utilization in biomedical applications. Recently, the reported finding of methylene dianiline (4,4′-diaminodiphenylmethane, MDA) in the aqueous extracts of autoclaved 4,4′-diphenylmethane diisocyanatebased polyurethanes promoted our investigation of the origin and extent of extractable methylene dianiline in polyurethanes. A high-pressure liquid chromatography procedure using precolumn derivatization is utilized to selectively monitor the appearance of this diamine in the aqueous extracts of polyurethanes subjected to water immersion, heat aging, and various sterilization techniques. No MDA was found in the aqueous extracts of the treated polyurethane except for the case of prolonged steam autoclaving. The appearance of 3-5 ppb MDA in the extract under these conditions is attributed to hydrolysis of the polymer. The stability of the polyurethanes under most conditions renders these materials useful in biomedical applications.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The binding of metal ions from salts and from corrosion products of 316 LVM stainless steel and MP-35 to blood cells and serum proteins was studied in vitro. In the first series of experiments, metal salts were added to whole blood and then the blood separated into red cells, white cells, and serum. Nickel from nickel chloride or corrosion products of stainless steel bound in very small quantities to blood cells. Cobalt from cobalt chloride bound to both red cells and white cells. Chromium from chromic chloride (Cr3+) bound to cells in very small quantities whereas chromium from potassium dichromate (Cr6+) and corrosion products showed very high to binding to red cells and some binding to white cells. In a second series of experiments the blood was separated into its components and then the metal salts were added and the binding pattern was identical. In a third series of experiments serum which had interacted with the metal salts or corrosion products was separated into its components by isolectric focusing on polyacrylamide gels. Almost all of the metal, whatever the source, was detected in the albumin region of the gels indicating strong binding to albumin. These studies on the cell and protein binding of the metals help to explain the dissemination of corrosion products from the site of the implant and subsequent systemic responses by some individuals.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In an attempt to find an alternative procedure to the preclotting of porous textile vascular prostheses, the feasibility of an albumin coating and ethanol preservation technique has been evaluated by implanting albuminated polyester prostheses as substitutes in the thoracic aorta of dogs. Nine different grafts representing woven, knitted, and velour constructions were implanted for periods ranging from 4 h to 6 months. At the sacrifice, the grafts were excized for measurement of the thrombogenicity of the flow surface, for pathological examination by light microscopy and SEM, and for quantifying the changes in the textile structure during implantation. Also the kidneys were removed and examined for infarcts caused by trapped circulating emboli. The healing characteristics of the nine different grafts proved similar and followed the same sequence of events as preclotted control grafts. The albumin coating and ethanol preservation resulted in a somewhat slower rate of healing. Yet, given sufficient time, a more completely healed graft was achieved as evidenced by the presence of endothelial-like cells throughout the length of the graft. In addition, the albumin is believed to reinforce the textile structure by reducing the tendency to stretch and dilate in vivo.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 1115-1124 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: For intravascular implantation, a biofunctional surface seems to retard surface thrombosis upon synthetic materials. Prostaglandins, like PGI2, PGE1, and PGD2, etc., are believed to stimulate membrane-bound adenyl cyclase and thereby raise intracellular levels of c-AMP within platelets, which inhibit platelet adhesion and aggregation. A new procedure is suggested for the immobilization of prostaglandin E1 on an albuminated polymer matrix, through glutaraldehyde coupling. Materials thus prepared show dramatic antiplatelet effects, with regard to platelet adhesion, when compared with albumin-immobilized surfaces. The affinity of various modified surfaces toward platelet adhesion is studied, using washed platelets suspended in Tyrode's solution. Octane contact angle studies are used to develop an understanding of the varied nature of bound substrates at equilibrium on polymer surfaces. These are studied at the solid/liquid interface, which is closest to in vivo conditions. The plasma recalcification time demonstrates the anticoagulant properties of various surfaces. A possible role of PGE1 in reducing platelet activity in the presence and absence of vitamin C is discussed. This technique may be used in the development of nonthrombogenic surfaces on existing biomedical polymers. Simultaneous pharmaceutical modification of the blood with vitamin C may enhance the blood compatibility of the surface.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 669-677 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The release rates of 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU), an anticancer drug, from various kinds of silicone and silicone-nylon implantable and refillable devices were investigated in vitro. The devices were made with different surface areas and wall thicknesses. The relation of the release rate at steady state to the surface area and the relation of the release rate per unit surface area to the wall thickness were determined. The relationship among the release rate, the surface area, and the wall thickness was analyzed using the multiple regression method, and is represented on a three-dimensional graph. The multiple regression equation predicts the release rate from the surface area and the wall thickness; the release rate can also be read from a nomogram that is presented.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 721-733 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A method is presented that can be utilized for the removal of formalin-fixed tissues from arterial grafts without. Affecting fiber material properties. Such a method could prove highly useful for studying the changes in the structure and properties of graft fiber as functions of important clinical variables. Information on what actually happens to the arterial graft material in situ with passage of time is greatly lacking in the current graft literature. The method proposed involves treatment of the formalin fixed fiber-tissue complex with an enzymatic preparation containing enzymes derived from the porcine pancreas (pancreatin) in solution with tris(hydroxymethyl) aminomethane buffer at pH 7.6. Studies with two different grafts - a Microknit Dacron Bifurcation from a clinical patient 10¼ years after implantation and stored in formalin for 11 months, and a Sauvage Filamentous Velour of Dacron from an animal 24 h after implantation and stored in formalin for nine months - showed that the treatment was highly effective in completely removing the tissues at concentrations of pancreatin as low as 2.5%. The same treatment given to the virgin yarns of grafts revealed no significant effects on tensile, dimensional, and morphological properties.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The slow crack propagation velocity v, which depends on the stress intensity factor K, has been measured for three different high-density aluminas. Assuming a load history for the prosthesis which approximates conditions during walking, the lifetimes of the components of a total hip endoprothesis were calculated as a function of the initial flaw size. Different geometries for the preexisting cracks, as well as varying physiological parameters, were considered. It is shown that the lifetime is very dependent on the quality of the material and that it is reduced by increased body weight, walking speed, and varus positioning. Comparison of failure behavior in different parts of the femoral component showed that flaws in the stem must be one order of magnitude smaller than those in the neck to achieve comparable lifetimes.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 715-719 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Questions have been raised about the use of mercury intrusion porosimetry to measure interconnecting pore sizes and void volumes in relatively soft and flexible materials such as porous implant composites of PTFE and carbon fibers. We have studied the effect of precompression of one such commercial composite on the mercury intrusion curves which cover all pore diameters greater than about 16 μm, the range of interest for tissue ingrowth applications. Prior compression by a pressure 20% greater than that encountered by the material during a mercury intrusion experiment did not change the ensuing pore size distribution curve, as compared with a noncompressed sample. Deformation of the material at higher pressures sufficient to decrease the sample volume inelastically by 17, 33, and 67% changed the shape of the mercury intrusion curves significantly, indicating that this technique can be used to detect prior deformation of an “unknown” sample. In the undeformed material, less than 15% of the total void as measured by mercury porosimetry consists of interconnecting pores 〉 100 μm in diameter and more than 50% of the void volume is composed of pores 〈40 μm in diameter.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 735-740 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 755-755 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 767-774 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The experiment was designed to investigate the in vitro corrosion of several modern dental amalgams in saline solution over a six-month period by measuring changes in the soluble corrosion products. Based on the change of the electrical conductivity of the solution, the dissolution rate seemed to decrease gradually for the first three to four months. Then a rapid increase was observed, indicating a reactivated corrosion process. Larger dissolutions of copper and mercury were observed, especially for the high copper alloys, in these later stages. Zinc and indium, if present, were preferentially released at the earlier stages. Silver and tin could not be detected. Evidence exists that the corrosion of tin results in insoluble deposits of corrosion products.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 757-766 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Various acylated chitins, including formyl, acetyl, propionyl, butyryl, caproyl, capryl, lauroyl, and benzoylchitin, were evaluated as materials for blood contact surfaces by means of contact angle and blood-clotting time measurements. Critical surface tensions of acylated chitins varied within the range of 20-30 dyn cm-1 and were dependent on the length of the acyl side chains. Furthermore, the dispersion and nondispersion components of the surface tension show remarkable differences which are dependent on the type of acyl group attached to chitin. The chitin derivative with 2.0 acetyl groups per N-acetylglucosamine residue gave values of the dispersive and nondispersive components of the surface tension that are very close to those obtained for glutaraldehyde-treated umbilical cord vessels. All of the acylated chitin surfaces show longer clotting times than the original chitin surface.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 811-826 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: During the normal functioning of aortic porcine bioprosthetic valves, the leaflets undergo complex configurational changes which can produce stresses large enough to damage the leaflets. Stress analyses of these valves in vivo have not been performed before. We investigated the behavior of aortic bioprostheses in vivo in calves by placing radiopaque markers on the valves and observing them under x-ray. Based upon the behavior of the leaflets, a method of stress analysis is proposed. Membrane stresses were associated with a pressure gradient across the leaflet and bending stresses with a change in the leaflet curvature. Total stresses were obtained by summation of the two stresses. A model of leaflet deformation at its attachment is proposed and the stresses determined. In diastole, the total stresses in the leaflet were tensile. In systole, the total stresses at the leaflet attachment were large and compressive on the aortic surface. Since the leaflet is unable to sustain compressive stresses, it is concluded that large compressive stresses cause structural damage at the leaflet attachment. This may explain the clinical observation that bioprosthetic leaflets detach or calcify in this region.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 209-230 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The mechanical properties of polyethylene components used in prosthesis are altered after fabrication by the sterilization procedure and by the environmental and mechanical aging which occurs after implantation. To assess the importance and extent of these alterations, ultrahigh molecular weight polyethylenes from two sources, Hercules 1900 and RCH 1000C, were subjected to gamma-ray irradiation and aging in serum and argon environments. Changes induced by these treatments in the structural and mechanical parameters have been determined by a variety of experimental techniques. The effect of irradiation is to introduce crosslinks and to increase the degree of crystallinity resulting in changes in the tensile properties in the direction of higher stiffness and reduced ductility. Aging for six months produced similar changes with subtle differences. The results suggest that the initially low degree of crystallinity which results from the sluggish mobility of the very long chain molecules offers the opportunity for significant changes in the properties during use in the long run.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 267-277 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We previously reported the use of polymeric delivery systems capable of sustained release of substances with molecular weights up to 2 × 106. The current study examined the tissue compatibilities of these slow-release agents and of other polymeric materials. To observe in vivo host responses to specific implants, tests were conducted in the rabbit cornea. The cornea as an implant site has several advantages compared to other organs including its clarity, avascularity, sensitivity, and convenient access to view. Corneas were examined using stereomicroscopy and histology. Two polymers suitable for sustained macromolecular release, poly(hydroxyethyl methacrylate), and alcohol-washed ethylene-vinyl acetate copolymer, were noninflammatory. Other polymers considered for sustained macromolecular release, such as polyacrylamide and poly(vinyl pyrrolidone), produced significant inflammation.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 289-290 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 279-288 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Auger electron spectroscopy was used to investigate the relative concentration of the calcium impurity at the external and fracture surfaces of a dense alumina after in vivo exposure for 6, 12, and 23 weeks. The Ca concentration at the external surface initially decreased, reached a minimum at 12 weeks, and increased thereafter. These results were compared with the flexural strength, which decreased nearly linearly from 6 to 23 weeks.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 383-392 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Rabbit hemolysate-loaded microcapsules having sulfonic acid groups on their surface were prepared and rabbit platelet adhesion onto the sulfonated surface was examined kinetically. Rabbit platelets adhered more markedly onto the surface of a higher charge density than that of a lower one, indicating a trend similar to that found in the case of the surface having carboxyl groups. Moreover, the platelets were found to be stickier in the buffer solution than in the plasma, though the dependence of platelet adhesion in the buffer solution on the magnitude of surface charge of the sulfonated artificial red blood cells was still recognized.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 363-381 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We studied the adsorption properties of plasma fibronectin (pFN) on wettable tissue culture (TC) dishes and nonwettable bacteriological (BAC-T) dishes in relationship to its biological activity of promoting fibroblast spreading. The binding of pFN to the dish surfaces was found to be very tight and partially resistant to treatments with 1M NaOH, 2% SDS, 8M urea, or 6M guanidine HCl. Only the combination of trypsin (1 mg/ml) followed by 1M NaOH resulted in complete recovery of surface bound material. The amount of surface bound pFN did not directly correlate with its activity when comparing TC and BAC-T dishes. At low concentrations, more pFN adsorbed onto the surfaces of BAC-T dishes than TC dishes, but the adsorbed material was biologically less active on BAC-T dishes. At high concentrations, pFN adsorbed similarly on both dish surfaces reaching a maximum level of 320 ng/cm2 or 4.4 X 1011 molecules/cm2. The possibility was considered that pFN unfolded into an inactive conformation when adsorbed on BAC-T dishes at a low concentration but that at high concentrations, molecular packing requirements prevented unfolding. Evidence in favor of this hypothesis was the observation that addition of 50 μg/ml of serum albumin simultaneously with low pFN concentrations resulted in adsorption of pFN on BAC-T dishes in an active conformation even though the amount of adsorbed pFN decreased. Competition experiments between pFN and other proteins were carried out, and it was found that pFN has a much higher affinity for BAC-T or TC dish surfaces than albumin or fibrinogen. It was also found that mild heat denaturation of albumin increased its affinity for the surface by an order of magnitude.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...