ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Gas chromatography  (108)
  • 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous
  • Early warning systems (earthquakes, volcanic eruptions, tsunamis etc.)
  • Seismology
  • Springer  (125)
  • Birkhauser Verlag,  (3)
  • Birkhäuser  (2)
  • Irkutsk : Ross. Akad. Nauk, Sibirskoe Otd., Inst. Zemnoj Kory
  • Krefeld : Geologischer Dienst Nordhein-Westfalen
  • München : Bayerisches Landesvermessungsamt
  • 2005-2009  (15)
  • 1980-1984  (115)
Collection
Keywords
Publisher
Years
Year
  • 1
    Publication Date: 2020-12-23
    Description: In July 1998, an Mw = 6.2 earthquake struck the islands of Faial, Pico and San Jorge (in the Azores Archipelago), registering VIII on the Modified Mercalli Intensity scale and causing major destruction in the northeastern part of Faial. The main shock was located offshore, 8 km North East of the island, and it triggered a seismic sequence that lasted for several weeks. The existing data for this earthquake include both the general tectonic environment of the region and the teleseismic information. This is accompanied by one strong-motion record obtained 15 km from the epicentre, the epicentre location of aftershocks, and a large collection of the damage inflicted to the building stock (as poor rubble masonry, of 2-3 storeys). The present study was carried out in two steps: first, with a finite-fault stochastic simulation method of ground motion at sites throughout the affected islands, for two possible locations of the rupturing fault and for a large number of combinations of rupture mechanisms (as a parametric analysis); secondly, the damage to buildings was modelled using a well-known macroseismic method that considers the building typologies and their associated vulnerabilities. The main intent was to integrate different data (geological, seismological and building features) to produce a scenario model to reproduce and justify the level of damage generated during the Faial earthquake. Finally, through validation of the results provided by these different approaches, we obtained a complete procedure for the parameters of a first model for the production of seismic damage scenarios for the Azores Islands region.
    Description: Published
    Description: 361–381
    Description: 5T. Sismologia, geofisica e geologia per l'ingegneria sismica
    Description: JCR Journal
    Description: open
    Keywords: Stochastic finite-fault scenarios ; Building damage assessment ; 9th July Faial earthquake ; Azores Islands ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2017-04-04
    Description: A modelling of the observed macroseismic intensity of historical and instrumental earthquakes in southern Spain is proposed, with the aim of determining the macroseismic parameters for seismic hazard evaluation in a region in which the characterization of intensity distribution of seismic events shows different levels of difficulty referable to the complex faults system of the area in study. The adopted procedure allows an analytical determination of epicenters and principal attenuation directions of earthquakes with a double level of verification with reference to the maximum shaking area and structural lineaments of the region, respectively. The analyses, carried out on a suitable number of events, highlight, therefore, some elements for a preliminary characterization of a seismic zonation on the basis of the consistency between seismic intensity distribution of earthquakes and corresponding structural framework.
    Description: Published
    Description: 747-760
    Description: 5.1. TTC - Banche dati e metodi macrosismici
    Description: JCR Journal
    Description: reserved
    Keywords: Attenuation directions, southern Spain, macroseismic intensity, virtual intensity. ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2017-04-04
    Description: An anisotropic attenuation law, based on an anisotropic characterization of intensity distribution for seismogenic zones, is proposed. This approach, that distinguishes itself for its consistency to the observed data, initially reconfigured by filtering procedures, is particularly suitable for seismic hazard evaluation.
    Description: Published
    Description: 707-714
    Description: JCR Journal
    Description: reserved
    Keywords: Attenuation law, virtual intensity distribution, seismic hazard. ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2017-04-04
    Description: For the seismic hazard evaluation of the region including the southern Calabro- Peloritanian Arc and southeastern Sicily, the determination of the macroseismic virtual intensity distributions has been carried out, characteristic of the seismogenic zones that fall within the area in study, starting with the structural framework of the region and from the analysis of the observed intensity effected through suitable filters. The macroseismic parameters, derived from such virtual distributions and used for seismic hazard evaluation, are not only a reference for eventual subsequently deeper knowledge referable to the need for a better characterization of the reference modelling, but distinguish themselves as an essential instrument for the definition of seismic hazard scenarios correlated to seismic events that take place in single seismogenic zones.
    Description: Published
    Description: 739-746
    Description: 5.1. TTC - Banche dati e metodi macrosismici
    Description: JCR Journal
    Description: reserved
    Keywords: Seismogenic zones, virtual intensity distribution, seismic hazard. ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-01-30
    Description: Within the framework of the European LESSLOSS Project “Risk Mitigation for Earthquakes and Landslides”, finite-fault seismological models have been proposed for the computation of earthquake scenarios for three urban areas: Istanbul (Turkey), Lisbon (Portugal) and Thessaloniki (Greece). For each case study, ground motion scenarios were developed for the two most probable events with different return periods (generally 50 and 500 years), locations and magnitudes that were derived from historical and geological data. The ground motion simulations were performed in the frequency band of engineering interest (0.5-20 Hz) by two numerical finite-fault methods: a hybrid deterministic-stochastic method, DSM, used for all of the cases investigated, and a non-stationary stochastic finite-fault simulation method, RSSIM, applied only in the case of Lisbon. In the present study, the results with respect to bedrock and surface are presented in terms of peak ground acceleration (PGA) for the city of Lisbon and the surrounding area, using earthquake scenarios from the onshore source area of the Lower Tagus Valley, and from the offshore source area of the Marques de Pombal fault, which is one of the possible sources of the 1755 Lisbon earthquake. Site effects are evaluated by means of a properly designed equivalent stochastic non-linear one-dimensional ground response analyses of stratified soil profile units. The requirements of the users (e.g., engineers, local administrators) constrain the choice of the scenario that can be adopted as input for disaster scenario predictions and loss modelling; in the case of Lisbon, the maximum values of shaking were assumed as the criteria for the reference scenarios.
    Description: Published
    Description: 233-243
    Description: 3T. Storia Sismica
    Description: open
    Keywords: Simulating Earthquake Scenarios ; European LESSLOSS project ; The Case of Lisbon ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: book chapter
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2022-05-24
    Description: In the framework of the SESAME project one of the taskswas the compilation of all available ambient noise measurements within urban environments affected by historical or/and recent strong earthquakes in Europe. The aim of such a task was to give an answer to the question; “How does horizontal-to-vertical ambient noise spectral ratio compare with damage in modern cities?”. For this purpose five European urban areas, namely, Angra do Heroismo (Portugal), Fabriano and Palermo (Italy), Thessaloniki and Kalamata (Greece) were selected for which spatial damage information was available either in terms of modified Mercalli intensity or in EMS98 damage grades. The geological setting of the examined sites as well as the causative earthquakes are satisfactorily known. Ambient noise recordings compiled for all examined sites have been homogeneously processed by a technique developed and agreed upon SESAME project. Using a standard multivariate statistical analysis, namely, factor analysis and canonical correlation, the horizontal-to-vertical ambient noise spectral ratio (HVNSR) is correlated with damage pattern observed within examined urban areas. Results show that, in some cases (Thessaloniki, Palermo), the HVNSR seems to be able to differentiate between areas previously shown to be associated with higher damage. In other cases however (Angra do Heroismo, Fabriano, Kalamata), the correlation is not statistically significant indicating thus the complex character of the parameters involved, implying that currently there is no a straightforward way that a value of HVNSR can correctly predict the extent to which a given region will be associated with increased damage.
    Description: Published
    Description: 109–140
    Description: 4.1. Metodologie sismologiche per l'ingegneria sismica
    Description: JCR Journal
    Description: reserved
    Keywords: Ambient noise ; Site effect ; Macroseismic intensity ; Factor and canonical analysis ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2017-04-03
    Description: The aim of this study is to shed light ontwo important destructive seismicsequences, about 20 years apart (1138–1139and 1156–1159), which hit the northernsector of the Dead Sea transform faultsystem (DSTFS), in the easternMediterranean region. Although some ofthese earthquakes were already known to thescholarly tradition, the interpretationsprovided until today have largely beenpartial and characterised by uncertaintiesand discrepancies among the variousauthors. Our study has developed throughresearch into the original Arabic, Syriac,Armenian and Latin texts and a criticalanalysis relating to a territory fragmentedby the presence of the Christian-Latinstates. This analysis has allowed us toshed light on the already existing, albeitoften uncertain, information and to add newelements of these two important series ofearthquake shocks to our knowledge base.As regards the first seismic sequence(October 1138–June 1139), apart from havingdefined the date with greater accuracy,eight new locations affected have beenidentified, unknown to previous studies.The shocks jolted a vast area withdestructive effects, including theterritory of Aleppo (modern Halab, Syria)and the western part of the region ofEdessa (modern Urfa, Turkey).The second seismic sequence (September1156–May 1159) was much longer anddevastating, and hit a huge area, includedbetween the present-day territories ofnorth-western Syria, northern Lebanon andthe region of Antioch (modern Antakya, insouthern Turkey). A detailed analysis ofthe primary sources has allowed toreconstruct the series of shocks withchronological detail of the effects,improving our previous knowledge. Lastly,the authors formulate an hypothesis as tothe possible seismogenic zones affected.
    Description: Published
    Description: 105-127
    Description: 3.10. Sismologia storica e archeosismologia
    Description: JCR Journal
    Description: reserved
    Keywords: Historical earthquakes ; seismic sequences ; Lebanon ; Syria ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.05. Historical seismology
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    facet.materialart.
    Unknown
    Springer
    In:  Norwell, Springer, vol. 6, no. 3, pp. 2-203, (ISBN: 3-540-26532-5, XVI + 208 p. 72 illus.)
    Publication Date: 2005
    Keywords: FractureT ; Seismology ; Geoelectrics ; Electromagnetic methods/phenomena ; Geothermics ; Non-linear effects ; Dynamic ; Earth ; system ; geophysics ; Inhomogeneity ; scaling
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    facet.materialart.
    Unknown
    Springer
    In:  Amsterdam, Springer, vol. 1, pp. 225, (1-4020-3353-2)
    Publication Date: 2005
    Keywords: Tsunami(s) ; Earthquake risk ; Earthquake precursor: prediction research ; Review article ; Early warning systems (earthquakes, volcanic eruptions, tsunamis etc.) ; Modelling ; NATHAZ ; measurement, ; tsunami ; model, ; data ; assimilation, ; data ; inversion, ; tsunami ; warning, ; tsunameters, ; forecast, ; hazard ; mitigation
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    facet.materialart.
    Unknown
    Birkhäuser
    In:  London, 2nd ed., Birkhäuser, vol. 4, no. ALEX(01)-FR-77-01, AFTAC Contract F08606-76-C-0025, pp. 329, (ISBN: 3-7643-7295-8)
    Publication Date: 2005
    Keywords: Handbook of geophysics ; Review article ; Seismology ; Statistical investigations ; Modelling ; Source ; PAG ; Omori ; Bath ; Gutenberg-Richter magnitude frequency b-value ; FractureT ; scaling ; Zuniga
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    facet.materialart.
    Unknown
    Springer
    In:  Professional Paper, Perspectives in Modern Seismology, Dordrecht, Springer, vol. 65, no. 16, pp. 145-168, (ISBN 0080419208)
    Publication Date: 2005
    Keywords: paleo ; Seismicity ; Fault zone ; DSTF ; Seismology ; Early warning systems (earthquakes, volcanic eruptions, tsunamis etc.) ; Bucharest ; Romania ; Earthquake risk
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    facet.materialart.
    Unknown
    Springer
    In:  Bull., Polar Proj. OP-O3A4, Perspectives in Modern Seismology, London, Springer, vol. 201, no. XVI:, pp. 169-184, (ISBN: 3-540-23712-7)
    Publication Date: 2005
    Keywords: Crustal deformation (cf. Earthquake precursor: deformation or strain) ; Geodesy ; Finite Element Method ; Modelling ; Three dimensional ; Seismology ; Early warning systems (earthquakes, volcanic eruptions, tsunamis etc.) ; Bucharest ; Romania ; Earthquake risk
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    facet.materialart.
    Unknown
    Springer
    In:  Bull., Polar Proj. OP-O3A4, Perspectives in Modern Seismology, Dordrecht, Springer, vol. 20, no. 4, pp. 47-65, (ISBN 0080419208)
    Publication Date: 2005
    Keywords: Non-linear effects ; Seismology ; Early warning systems (earthquakes, volcanic eruptions, tsunamis etc.) ; Bucharest ; Romania ; Earthquake risk
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    facet.materialart.
    Unknown
    Springer
    In:  Bull., Open-File Rept., Perspectives in Modern Seismology, Arnsberg-Neheim, Springer, vol. 10, no. 87-17, pp. 69-94, (ISBN 0080419208)
    Publication Date: 2005
    Keywords: Plate tectonics ; hot ; spots ; GeodesyY ; Tomography ; Seismology ; Early warning systems (earthquakes, volcanic eruptions, tsunamis etc.) ; Bucharest ; Romania
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    facet.materialart.
    Unknown
    Springer
    In:  Professional Paper, Open-File Rept., Perspectives in Modern Seismology, Berlin, Springer, vol. 1, no. 16, pp. 1-12, (ISBN 0080419208)
    Publication Date: 2005
    Keywords: Review article ; Seismology ; Early warning systems (earthquakes, volcanic eruptions, tsunamis etc.) ; Bucharest ; Romania ; Earthquake risk
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Esterification in aqueous solution ; n-Butyl esters of C2−C16 dicarboxylic acids ; Dicarboxylic acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary C2−C16 dicarboxylic acids were esterified in aqueous solution in the presence of sulfuric acid. Esterification in water/n-butanol mixtures with mole ratios between 0.02 and 2.53 can be utilized for the quantitative determination of the dicarboxylic acids by gas chromatography. The presence of water does not interfere at water/n-butanol mole ratios below 0.27. For mole ratios above 0.27 anhydrous sodium sulfate has been used for binding the water. The mole ratio range was 0.25–0.75 for anhydrous sodium sulfate/water, and 0.32–1.3 for sulfuric acid/anhydrous sodium sulfate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 663-667 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Gas solubilities ; Enthalpies of solution ; Polar solutions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas-liquid chromatographic method has been used to determine the solubilities and partial molar enthalpies of solution of the gases H2S, CO2 and COS in four polar solvents. The results agree well with literature values obtained using conventional techniques, with the one exception of H2S in N-methyl-2-pyrrolidinone. In this case there is some evidence for the occurrence of adsorption at the gas-liquid interface.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Esterification in aqueous solution ; n-Butyl esters of aromatic polycarboxylic acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The direct esterification and gas chromatographic analysis of aromatic carboxylic acids as n-butyl esters is described. Derivatization is performed in aqueous solution with n-butanol in the presence of sulfuric acid. The butyl esters of benzoic, phthalic, hemimellitic, trimellitic, trimesic and pyromellitic acids permit their gas chromatographic separation from each other and from fatty acids and alipatic dicarboxylic acids. At mole ratios of [H2O]/ [n-BuOH]≤0.04 the water present does not interfere with the esterification reaction. At mole ratios above 0.04 anhydrous sodium sulfate is used for binding the water, at mole ratios of [Na2SO4 anh.]/[H2O]=0.25–0.75.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 202-204 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Polysiloxane stationary phases ; Heat of adsorption ; Heat of solution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The changes in the heat of solution of polar compounds and xylene isomers in methylsilicone fluid OV-101 deposited on Chromosorb W AW DMCS were studied. It was shown that the heat of solution increases with an increase of the percentage loading of the OV-101 up to 10%. Solution and adsorption thermodynamic characteristics of the studied system are briefly discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Metal complexes ; Chemically bonded phase
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Packings consisting of diphenylphosphine complexes with CoCl2 and CoBr2, chemically bonded to the silica surface, were synthesized and their retention parameters determined. The packings are capable of specifically interacting with electron-donating compounds by forming π-complexes. The interaction is considerably stronger in the case of CoBr2-containing packing than in the case of CoCl2-containing packing.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 234-238 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular columns ; On-column injection ; Stopped-flow operation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple, inexpensive, on-column injector of the septum moving-needle kind is described for quantitative analysis using open-tubular columsn. when operated in the stopped-flow mode an improvement incolumn efficiency is observed combined wit a diminished tendency to produce split-top peaks, particularly for late eluting peaks. Using electronic integration a relative error of about 2.7% was observed for peaks spanning a wide range of sample concentrations and volatilities.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 243-248 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carrier gas ; Viscosity ; Influence of temperature
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The vicosity-temperature relationship of the three gases (helium, nitrogen and hydrogen) most frequenly used as the carrier gas in gas chromatography is studied. Based on available data, equaitions are derived to describe this relationship. Using these equations viscosity data are tabulated for the chromatographically important temperature range.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 260-264 
    ISSN: 1612-1112
    Keywords: Parabens and their dissolution ; Pharmaceutical dosage forms ; Derivatization ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A specific, sensitive and general applicabla gas chromatographic method is described for the determination of parabens in various liquid pharmaceutical preparations: propylparaben and butylparaben in a liquid antacid dosage form (I); methylparaben, ethylparaben and propylparaben in a syrup (II); methylparaben and propylparaben in a solution for injection (III). Each time one of the parabens is used as internal standard. The parabens are extracted with diethylether and derivatized by silylation. Different columns are used for the analysis of the parabens: 3% SE-30 column, a 3% QF-1 column for different selectivity, a 2% OV-1 column for isothermal operation. Special attention is attributed to the standard: the parabens are dissolved in a minimal amount of 0.1 M sodium hydroxide and extracted in the same way as the pharmaceutical dosage form.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Configuration ; Resolution ; Alcohols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The study of the resolution of sixteen secondary aliphatic alcohols by gas chromatography on (+)-dodecyl (2R, 3R)-tartrate, trapping the ascending part of the peak from a conventional filled column, has allowed the determination in a single operation of the sign and order of emergence of enantiomers. A correlation between the configuration of these secondary alcohols and their order of emergence has been established.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 309-312 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carboxylic acids ; Acetonyl derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation of the acetonyl esters of nine aliphatic carboxylic acids is described, the general formula of the derivatives being RCOOCH2COCH3 where R=alkyl or H. The derivatives show good chromatographic properties on both packed and capillary columns. The electron impact and chemical ionisation mass spectra of the derivatives are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Thermodynamic relationships ; Retention index ; Peak identification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A thermodynamic criterion, ΔQ, is suggested which permits to estimate the difference in the functional group energy of interactions for two different stationary phases. The linear dependence of ΔQ on the homolog number m of any series Rm X can be used as the thermodynamic criterion for the identification of substances by GC analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 477-488 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open tubular (capillary) columns ; Sample capacity ; Column comparison ; Film thickness ; Column diameter
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Wall-coated, open-tubular (capillary) columns prepared from different diameter tubing, with different liquid phase film thickness, are compared with each other and with packed and support-coated open-tubular columns. The comparison is based on the variation of the phase ratio and the capacity factor, and includes column efficiency (HETP, theoretical plate number), resolution, retention time, and sample capacity. Problems associated with the evaluation of the sample capacity are outlined. The influence of temperature on column performance is discussed in detail. Finally, the possibilities of short, wide-bore open-tubular columns prepared with a thick liquid-phase film are demonstrated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 367-368 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open tubular (capillary) columns ; Variation of film thickness ; Thick-film columns ; Mass transfer terms
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The factors characterizing the influence of the variation of the liquid phase film thickness on the mass transfer terms in the Golay equations describing the performance of open tubular columns are investigated and numerical values are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Cross-linked Stationary phase ; Immobilized Stationary phase ; Packed columns ; Trapping
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A coating of silicone SE-54 on Chromosorb W has been converted to an analytically stable, immobilized stationary phase layer by cross-linking with an organic peroxide. Up to 10% by weight has been applied in this manner. Excellent high temperature qualities are exhibited, such as low bleeding and good base line stability, during typical analyses. Poly (2,6-dimethyl-p-phenylene oxide) has also been crosslinked as a surface coating on Chromosorb W with an organic peroxide. From 3 to 4% by weight has been immobilized in this way. The resultant packing material, following high temperature conditioning, has been examined for use as an adsorbent of trace substances, similar to the applications to which such adsorbents as Tenax GC have commonly been applied, e.g. trace analysis of air. It appears to exhibit satisfactory properties for this analytical purpose.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 21-22 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Isopropylidene-glucose ; Glucose ; GC of TMS-derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper describes the gas chromatographic separation of the mixture of di- and mono-O-isopropylidene-D-glucose and D-glucose as their trimethylsilyl derivatives. The use of OV-101 as liquid phase provides a complete separation for the all components in the mixture. Quantative analysis was performed using xylitol as the internal standard for di- and mono-O-isopropylidene-D-glucose, and sorbitol as the internal standard for α-and β-glucose.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Nuclear magnetic resonance ; Terpenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure is described for recording1H NMR spectra of flowing gaseous GC fractions boiling as high as 200°C. The line width of the signals in the NMR spectra is smaller than 2.2Hz.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 556-559 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid chromatography ; Tetramethrin ; Residues
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the analysis of tetramethrin aqueous formulation and residues of tetramethrin on woolen cloth. The samples were extracted with acetonitrile and partitioned with benzene. Interferences were removed by liquid column chromatography with acid alumina and eluted with 10% ethyl acetate-hexane. Analysis was by gas chromatography with a 10% UCW98 (methylsilicone) column. Detection was made with the flame ionization detector to avoid the repeated dilutions necessary with use of the electron capture detector.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Electric parameters ; Physico-chemical relationships ; Structure-retention study
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new equation is derived relating the retention index to the molecular polarizabilities, ionization potentials and permanent dipole moments of the stationary phase and the solute. Various implications of this equation to quantitative structure-retention relationships are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    ISSN: 1612-1112
    Keywords: Aldehydes and ketones ; 2,4-dinitrophenylhydrazine-coated silica gel ; Gas chromatography ; Column liquid chromatography ; Pollution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary After a brief review of several methods described in the literature this paper discusses air-sampling on 2,4-dinitrophenylhydrazine-coated silica gel and identification requirements for aldehydes and ketones most commonly found in industrial pollution. Quantitative analysis of formaldehyde and acetaldehyde either by GC or by HPLC techniques is established using a dynamic system producing test atmospheres and compared with the usual colorimetric determinations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    facet.materialart.
    Unknown
    Springer
    In:  Heidelberg, Springer, vol. V/2, no. Subvol. a, pp. 220, (ISBN: 0-08-037951-6)
    Publication Date: 1984
    Keywords: Review article ; Seismology ; (The Earth's free) oscillations ; Waves ; Gravimetry, Gravitation ; Geomagnetics ; Planetology ; solar ; system ; Anderson ; Brosche ; Busse ; Dziewonski ; Groten ; von ; Herzen ; Jackson ; Janle ; Kahle ; Maelzer ; Meissner ; Mueller ; Prodehl ; Rybach ; Schneider ; Suendermann ; Waenke ; Wilhelm ; Zuern
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    facet.materialart.
    Unknown
    Springer
    In:  Bull., Polar Proj. OP-O3A4, Physical Properties of Rocks, Heidelberg, Springer, vol. V/2, no. Subvol. a, pp. 61-83, (ISBN 0080419208)
    Publication Date: 1984
    Keywords: Review article ; Seismology ; (The Earth's free) oscillations ; Waves ; Muller ; Zuern ; Zurn
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Springer
    Entomologia experimentalis et applicata 34 (1983), S. 20-26 
    ISSN: 1570-7458
    Keywords: Dioryctria abietella ; Cone pyralid ; Lepidoptera ; Pyralidae ; Sex pheromone, (Z,E)-9,11-tetradecadienyl acetate ; Single sensillum recordings ; Electroantennography ; Gas chromatography ; Mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Résumé L'analyse en chromatographie gazeuse associée à une détection électroantennographique a montré que l'acétate (Z,E)-9,11-tétradécadiényle (Z,E)-9,11–14:Ac est l'un des composants de la phéromone de Dioryctria abietella Schiff (Lepid.: Pyralidae). Couplage chromatographie en phase gazeuse spectrometrie de masse a montré la présence d'acétate tétradécadiényle avec un spectre de masse et un indice de rétention identiques au Z,E-9,11–14:Ac Un récepteur cellulaire sensible à la fois au Z,E-9,11–14:Ac et à un extrait de la femelle a été identifié sous l'antenne du mâle. Les analyses des antennogrammes et de la cellule isolée ont étayé la caractérisation du composant de la phéromone comme étant Z,E-9,11–14:Ac. Un récepteur cellulaire additionnel sensible à l'acétate (Z.)-9-tétradécadiényle et à l'acétate (Z.E.)-9,12-tétradécadiényle a été trouvé sur l'antenne du mâle, mais il n'était pas activé par l'extrait de la femelle. Sur le terrain Z,E-9,11–14:Ac, présenté seul, attirait des nombres importants de mâles de D. abietella. L'addition de l'acétate (Z)-9-tétradécényle a inhibé l'attraction des mâles par les pièges.
    Notes: Summary Gas chromatographic analyses coupled with electro-antennographic detection indicated that (Z,E)-9,11-tetradecadienyl acetate (Z,E-9, 11–14:Ac) is a pheromone component of the cone pyralid Dioryctria abietella. Gas chromatographic-mass spectrometric analyses confirmed the presence of a tetradecadienyl acetate with mass spectrum and retention index identical to Z,E-9,11–14:Ac. A receptor cell sensitive to both Z,E-9,11–14:Ac and the female extract was identified on the male antenna. An additional receptor cell sensitive to (Z)-9-tetradecenyl acetate and (Z,E)-9,12-tetradecadienyl acetate was found on the male antenna but was not activated by the female extract. In the field Z,E-9,11–14:Ac presented alone attracted significant numbers of male D. abietella. Addition of (Z)-9-tetradecenyl acetate inhibited the attraction of males to traps.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 269-284 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid chromatography ; Phenols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas and high-performance liquid chromatographic methods in the analysis of phenols are reviewed. Among the great number of phenolic compounds analyzed, alkylphenols, chlorophenols, dihydroxy- and trihydroxybenzenes and biphenols are chiefly considered. The advantages and drawbacks of the methods are discussed, quoting the most important work. Relationships between the structural characteristics of phenols, the stationary phase structure, the mobile phase composition and the retention data are treated. Typical examples of the conditions for GC and HPLC analysis are summarized in tables. The literature comprises over 270 references, most of them recent.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Average molecular polarizability ; Retention index ; Polycyclic aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The Kováts retention indices of 10 polycyclic aromatic hydrocarbons were determined on SE-30, OV-101, SE-52, OV-7 and OV-17 stationary phases. A significant correlation has been found between the retention indices and the average molecular polarizabilities of the analyzed substances. Equations were derived for the direct determination of the average molecular polarizabilities from the retention index values. The influence of the temperature on this relationship is also indicated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    ISSN: 1612-1112
    Keywords: Esterification in aqueous solution ; iso butyl esters of C1–C20 fatty acids ; Gas chromatography ; Fatty acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary C1–C20 carboxylic acids have been esterified in aqueous solutions with i-butanol. Gas chromatographic analyses have been performed from a single chromatogram. It has been established that esterification in the concentration range of [H2O]/[i-BuOH]=0.01–10.3 can be utilized for the quantitative determination of these carboxylic acids. The presence of water does not interfere in the range of [H2O]/[i-BuOH]=0.01–1.03. In the cases of [H2O]/[i-BuOH]〉1.03, anhydrous sodium sulfate has been used for binding the water, in an amount of [Na2SO4]anh./[H2O]≥0.2.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 33-36 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Preparative scale chromatography ; Capacity ; Dual-step separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The capacity of dual-step preparative chromatographic separation systems is considered. It is shown that dualstep separation makes it possible to enhance the capacity of preparative installations as compared with single- and dual-stage purification of the compounds.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 44-46 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Natural gas analysis ; Poropak N
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple gas chromatographic method is described for the rapid analysis of natural gas using thermal conductivity detectors and programmed-temperature operation of a single Poropak N column. The method permits the determination of nitrogen, carbon dioxide and hydrocarbons containing one to seven carbon atoms.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 553-559 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Immobilized liquid phases ; Thick-film columns ; Diffusion coefficients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The influence of the liquid phase film thickness in open-tubular (capillary) columns on the individual resistance-to-mass-transfer terms and on the overall column efficiency is examined from the theoretical point of view. Methods for the calculation of the diffusion coefficients are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Immobilized liquid phases ; Thick-film columns ; GC-FTIR
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The performance of a column prepared with an immobilized (chemically bonded) methylsilicone phase having a film thickness of 5μm is investigated in detail. Due to their high sample capacity, such columns are particularly useful when directly coupling gas chromatography with spectroscopic techniques such as Fourier-transform infrared spectroscopy. Thick-film columns can even be used with thermal conductivity detectors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 600-604 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Alkyl benzenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The additivity concept in the retention index system of Kovats has been examined for a series ofn-alkylbenzenes and theiro- andp-monosubstituted nitro-, amino-, and chloro-derivatives. Anomalous behaviour is exhibited by the first three members of the series on both polar and non-polar stationary phases. For addition of a methylene group ton-propylbenzene or ap-substituted derivative, it is found that the retention increment, Δl CH2, approaches 100 units. However, the strong inductive effect of the group in the ortho position and the steric effects apparent in ano-substituted alkylbenzene lead to large variations of retention increment upon addition of-CH2-to the alkyl chain. A study ofn-alkylbenzene retention on Apiezon L and Carbowax 20M over a wide range of temperatures has verified the linearity of the retention increment with temperature and has revealed that this gradient increases with increasing carbon side-chain length for the first few members of the series, thereafter becoming constant. Functional retention increments, Δlx, for substitution of nitro-, amino- and chloro-groups into the benzene ring are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 691-692 
    ISSN: 1612-1112
    Keywords: Dichlorophenol isomers ; Sodium benzenesulfonate ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary It is difficult to separate all the dichlorophenol isomers as free phenols by gas-liquid chromatography. However they were effectively separated on 4,4′-dimethoxyazoxybenzene (liquid crystal), and all the isomers were separated appreciably well on sodium 1-naphthalenesulfonate, 2-naphthalenesulfonate and dodecylbenzenesulfonate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 65-69 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Oxygenates ; Fused-silica capillary columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method of analysing gasolines that contain oxygenates has been developed. The method uses a single fusedsilica capillary column and gives quantitative data for the oxygenates and the hydrocarbons in one analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Trace analysis ; GC-concentration ; Enrichment factor ; Theoretical evaluation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Based on gas chromatographic retention data obtained on a given adsorbent and at a given trap efficiency at different temperatures new equations are proposed for the evaluation of the enrichment factor. These equations are suitable under various preconcentration conditions such as: equilibrium saturation, complete trapping and permissible losses. Compared to known expressions for the evaluation of the enrichment factor the equations suggested consider the band broadening of the impurity in a trap causing a loss of the substance at the adsorption stage and dilution of the sample during desorption when the desorbed impurities are directed into the gas chromatographic column without intermediate freezing out in an graphic column without intermediate freezing out in an empty tube. The new equations may be used to select the optimum preconcentration conditions providing the necessary sensitivity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 191-194 
    ISSN: 1612-1112
    Keywords: Thermal treatment of MgO and MgCO3 ; Adsorption properties ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The changes in the chromatographic properties of MgO and MgCO3 due to thermal treatment was investigated. The experimental results show that thermally treated MgO and MgCO3 can be used as stationary phase for the gas-adsorption chromatography of hydrocarbon mixtures.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 418-420 
    ISSN: 1612-1112
    Keywords: Separation of metal chelates ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A very good separation of the acetylacetonate of AL-(III), Cr(III) and Co(III) has been obtained by gas chromatography, on a column containing OV-17 silicone oil as the stationary phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 421-425 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Purge and trap sampling ; Cryogenic focussing ; Water analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The most important operating parameters of a commercial purge and trap GC apparatus have been investigated. Band broadening problems arising from the slow desorption of compounds from the Tenax trap have been overcome by cryogenic focussing at the beginning of the column. Good results have been obtained with both packed and capillary columns. The sensitivity of the technique is sufficient to detect benzene in water at concentrations below 1μg kg−1 (1 ppb).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 241-243 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Detectors ; Flame ionization detector ; History of chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary On the occasion of the 25-year anniversary of its invention, this article summarizes the events which led to the development of the flame ionization detector.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    ISSN: 1612-1112
    Keywords: Esterification in aqueous solution ; n-Butyl esters of fatty acids ; Gas chromatography ; Fatty acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The esterification of C1−C8 fatty acid in aqueous solutions and in the presence of sulfuric or hydrochloric acid and with n-butanol is described. It has been established that the esterification can be used for the quantitative determination of these fatty acids in the concentration ratio range of [H2O]/[n-BuOH]=0.01–5.3. In the concentration ratio range of 0.01–0.8 the water present does not interfere. In the concentration range of above 0.8 anhydrous sodium sulfate is used for binding the water, in the amount of [Na2SO4.anh.]/[H2O]≥0.2.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 472-476 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid stationary phase ; Liquid phase bleeding
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The theory of the evaporation of the liquid stationary phase is elaborated and experimentally verified. On the basis of this theory the role played by the losses in the amount of liquid phase present is quantitatively determined. General techniques are examined which minimize the losses; these techniques are based on saturating the incoming carrier gas with liquid phase vapours and raising the pressure of the carrier gas in the column, e.g. by connecting a capillary to the column outlet in order to offer resistance to the gas flow. The application of these techniques ensures stable performance of the gas chromatographic columns using a volatile liquid phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Springer
    Pure and applied geophysics 120 (1982), S. 583-606 
    ISSN: 1420-9136
    Keywords: Seismology ; P-wave residuals ; Three-dimensional velocity inversion ; Velocity structure of Italy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract Jeffreys-Bullen P and PKP travel-time residuals observed at more than 50 seismic stations distributed along Italy and surrounding areas in the time interval 1962–1979, indicate the complex velocity pattern of this region. Strong lateral velocity inhomogeneities and low velocity zones are required to explain the observed pattern of residuals. In particular, late arrivals of about 1 sec are observed in the Apenninic mountain range, requiring both greater crustal thickness and low velocity layers, coherent with seismic refraction data and surface wave dispersion measurements. The seismic stations located in the Western and Eastern Alps indicate the presence of high velocities. In the Western Alps the strong azimuthal variation of residuals and the high values of early arrivals have a close relationship to the Ivrea body, an intrusive crustal complex characterized by a velocity as high as 7–7.2 km/sec. A travel-time inversion performed with theAki et al. (1977) block model, confirms the peculiar characteristics and the sharp variations in the lithosphere of the whole Italian region, with values of velocity perturbations between many adjacent blocks, ranging in size from 50 to 100 km, and independent from the earth parametrization chosen, reaching values up to 10% in the lithospheric part and 5% in the asthenosphere. 3-D inversion requires also high velocity along the Tyrrhenian coastal margin, equivalent to an uprise of major crustal and lithospheric discontinuities along this part of the Italian peninsula. Moreover low velocity material must be present in the northern part of the Adriatic foreland, in the lithosphere-asthenosphere system, closely related to the stress and seismicity pattern, and the lateral bending of the lithosphere in the same region.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    ISSN: 1612-1112
    Keywords: Teflon capillary columns ; Chemically modified teflon ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation of teflon capillary columns employing direct coating of the stationary phase to the chemically modified teflon surface and the role of the chemically modified teflon in the separation mechanism are described. Two types of contributions from the modified teflon have been observed: nonspecific adsorption of the carbon surface and specific interactions of polar groups in the carbon skeleton. The use of polar liquid phases can eliminate adsorption due to the presence of polar groups in the modified teflon.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 60-62 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Amines ; Derivatization ; Chloroformate esters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas chromatographic analysis of amines after conversion to electron capture sensitive carbamates in two-phase systems has been studied. Hydrophilic compounds, for instance methylamine, are reacted with 2,2,2-trichloro-tert. butyl chloroformate. Quantitation below 10−7 M can be made by thermionic or electron capture detection. A hydrophobic amine, namely N,N-dimethyl-n-octylamine, was derivatized with 2,4,6-tribromophenyl chloroformate with addition of iodide ion to the aqueous phase. The favorable effect of iodide ion as well as the choice of pH and chloroformate ester is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 98-102 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Rectangular channel ; Efficiency ; Capacity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatographic experiments have been performed in a truly rectangular channel with a 60∶1 cross-sectional aspect ratio, constructed according to the field-flow fractionation technology. It is shown that the peak broadening is controlled by the thickness of the channel while the maximum load is determined by the largest cross-sectional dimension. However, even with its elongated configuration, the side walls contribute significantly to the band broadening of solutes with a high diffusivity. Good agreement is found between the experimental plate height data and the recent theoretical calculations of Golay [13] taking into account the side-wall effect.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 704-706 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Isopropyliden-sorboses ; TMS-derivatives ; GC-MS combined technique ; Mass spectra
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method has been developed using gas chromatography — electron impact mass spectrometry for the determination of the di-0-isopropylidene-sorbofuranose and mono-0-isopropylidene-sorbofuranose. The compounds are separated as their trimethylsilyl derivatives on a capillary column coated with the stationary phase SE-52. The mass spectra show that the silylation reaction is quantitiative and that the isopropylidene groups does not change.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 183-185 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Analysis of ethylbenzene hydroperoxide ; Time normalization method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatographic method, based on the time normalization technique, is described for the analysis of ethylbenzene hydroperoxide in mixtures containing ethylbenzene, acetophenone, 1-phenylethanol, benzaldehyde and phenol. Different liquid phases were tested and the best results were obtained with tricresyl phosphate and neopentyl glycol sebacate. The influence of the support, the liquid loading and the gas velocity are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 625-630 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Comparison of liquid phases ; Influence of temperature ; Retention index data
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The influence of temperature and liquid phase film thickness of open-tubular (capillary) columns on the retention index values of hydrocarbons on methylsilicone liquid phases is discussed. Data obtained on methylsilicones and squalane are compared. Retention index values of 43 hydrocarbons between 40 and 70 °C on OV-101 liquid phase are listed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 351-354 
    ISSN: 1612-1112
    Keywords: Supported catalysts ; Reserved-flow GC ; Drying step ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Application of reversed-flow gas chromatography to study the drying step in the preparation of supported catalysts is proposed. It is demonstrated that this technique can be applied to investigate the kinetic law followed, as well as to obtain kinetic parameters of drying (rate constants, activation energies and frequency factors). Amaterial illustrating this application is γ-Al2O3 impregnated with usual organic solvents (n-C5H12,n-C6H14,n-C7H16, CH3COCH3 and CH3CH2OH). It was found that in all cases above a simple first-order law based onone kind of active site is followed. Moreover, it was observed that the activation energyE a of the drying process increases almost linearly with the relative molecular mass of the solvent, whereas for the same solventE a increases with the amount used. The operation of a kinetic compensation effect suggests “similar” activated complexes of the various solvents used.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Fused silica capillaries ; New polar phases: OV-1701 and RSL-310 ; Immobilization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The possibilities of OV-1701 and RSL-310, two new stationary phases, have been evaluated for capillary gas chromatography in fused silica columns. OV-1701 is a cyanopropylphenyldimethyl polysiloxane of moderate polarity possessing excellent chromatographic characteristics. The phase exhibits high coating and chromatographic efficiencies, high temperature stability and is suitable for cross-linking. RSL-310 is a polar liquid stationary phase yet to be permanently bonded in a capillary column. The selectivity of both phases extends the applicability of fused silica columns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 241-244 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Monosaccharides ; Polyols ; GC of TMS derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper describes the gas chromatographic separation of the mixture of isopropylidene monosaccharides, and their trimethylsilyl derivatives. Based on the total analysis time and resolution the best stationary phase was SF-96 using Chromosorb G as the solid support and temperature programming.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 312-314 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Injection-port modification ; Oxygen and nitrogen traces
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The paper presents a new device modifying normal injection port of a gas chromatograph for eliminating air contamination thus enabling determination of traces of oxygen or nitrogen. Further modification is also proposed which enables the analysis to be carried out with a limited quantity of sample gas. Potential application of this device in the analysis of reactive gases like florine has been indicated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    ISSN: 1612-1112
    Keywords: Phthalides ; Gas chromatography ; Chromosorb W ; Isomerization ; Ligustilide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary During GLC of naturally occurring mixtures of phthalides on packed columns an artefact was sometimes detected that originated from Z-ligustilide. Active sites of Chromosorb W were responsible for the formation of the artefact, that was assumed to be E-ligustilide as GC-MS revealed that its mass spectrum was identical with that of Z-ligustilide. No isomerization was observed when freshly coated Chromosorb W was used or the support was deactivated by benzoyl chloride or melamine. The identity of the artefact was confirmed by UV irradiation experiments.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 30-32 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Arsenic ; Inorganic materials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the quantitative chlorination and extraction of arsenic as arsenic trichloride from a number of alloys. The conditions for the quantitative gas chromatographic measurement of the volatile chloride have been studied. The proposed method for inorganic materials is very fast giving results within 10 min; sensitive, 1.5·10−13 g As can be detected, simple and accurate. At the ng level of As the error is about 20% with a standard deviation less than 20%, and at the 10pg level the error is about 36% with a standard deviation of 44%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 765-768 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Preparative scale chromatography ; Capacity ; Dual-stage separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The capacity of different versions of single- and dual-stage separation of mixtures on a preparative scale is considered. It has been shown that dual-stage separation with intermediate condensation considerably enhances the capacity of the installation as compared with a single-stage process.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 117-124 
    ISSN: 1612-1112
    Keywords: Various packed GC column ; Gas chromatography ; Porous layer beads ; GC/MS analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Theoretical comparisons of various packed GC column types are presented with respect to analysis time, efficiency, sample dilution, and sample capacity for a given maximum inlet pressure. In particular, totally porous particles, porous layer beads, and glass beads are compared with one another. It is shown that 30 μm porous layer beads offer a useful compromise between analysis time and plate count with relatively good sample capacity. Moreover, when using 1 mm i.d. columns (microbore), outlet flow rates that are reasonable for direct coupling to magnetic sector mass spectrometers are achieved making these columns suitable for GC/MS. Using 30 μm Zipax porous layer beads, columns yielding 8,000 to 10,000 plates/meter have been produced with inlet pressures of 13 to 26 atm. A simple modification of the injection port converts the maximum inlet pressure of a commercial gas chromatograph to 26 atm. With such pressures, columns in excess of 20,000 plates can be achieved. Chromatograms are presented illustrating the promise of these microbore columns for GC and GC/MS analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 245-248 
    ISSN: 1612-1112
    Keywords: Chromatoscopy ; Gas chromatography ; Graphitized carbon black ; Molecular structure and retention ; Aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A molecular-statistical calculation of the retention volumes at zero sample size on graphitized thermal carbon black is carried out for quasi-rigid molecules of fluorene, indene, 1-methylindene, 2-methylindene and three dimethylindenes. A reasonable agreement is observed between the calculated and the available experimental gas chromatographic data. The potential barrier to internal rotation and the torsional angle in styrene molecules are estimated by comparing theoretically calculated and measured retention volumes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Silicone liquid phases ; Oxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The on-column oxidation of apolar and polar silicones used as gas chromatographic stationary phases is investigated. Even at 225° the effects of oxidation are found to be slight. Of the materials investigated the methylphenylsilicones are the most stable.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    ISSN: 1612-1112
    Keywords: Glass capillary ; Gas chromatography ; Methyl chloroacetates ; Methyl chloropropanoates ; Methyl chlorobutanoates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas chromatography of all chlorinated methyl acetates, methyl propanoates and methyl mono- and dichlorobutanoates has been studied on Carbowax 20M and SE-30 glass capillary columns under various running conditions. The order of elution on a non-polar column was largely determined by the boiling point of esters, whereas on a polar column it was much influenced by the structure of compounds. Complete separation of the combined mixture of all 27 compounds could not be achieved, however, methyl 3,3-dichlorobutanoate was the only ester overlapped on both columns in spite of the various column temperatures used. The best separation of the mixture was on Carbowax 20M with a temperature program from 50°C at 8°C/min, isothermal running conditions leading either to poor separation of volatile components or long analysis time and broad peaks of higher chlorinated esters. The relative retention times for compounds at the various column temperatures are given and the retention order on a polar and on a non-polar column discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 517-520 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carbon-silica adsorbents ; n-Octadecanol film ; Phase transitions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The properties of the n-octadecanol film on carbon-silica adsorbent (Carbosil) were investigated. It was found that n-octadecanol forms an oriented film on the Carbosil's surface. If the surface of the basic silica gel is not completely covered with carbon, then the phase transition takes place in this film at a temperature higher than the melting temperature of n-octadecanol. One may distinguish two forms of this film, characterised by the different structures and the temperatures of the phase transitions. The first exists on the surface of silica gel unblocked by carbon. This part of the film is a monolayer, in which the alcohol molecules are vertically oriented. The solid compact-liquid expanded type phase transition at the well-defined temperature occurs in this film. In the second part of the film formed on the carbon surface, there is a multilayer of n-octadecanol. Its molecules are probably parallely oriented in relationship to the adsorbent surface. This film desintegrates progressively when the temperature increase. Maximum temperature of this phase transition is lower than the temperature of its analogue on pure silica gel surface.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 546-558 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Quantitative analysis ; Sample inlet systems ; High-speed analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The attainment of precise quatitative analytical data using open-tubular (capillary) columns in standard, commercially available gas chromatographic instrumentation is demonstrated. Key elements in the design and proper utilization of the instrumentation are discussed. The function of the various sample introduction systems is elaborated and their quantitative performance demonstrated. The extra-column contribution to band-spreading is determined and the resultant data is used assessing the suitability of commercial instrumentation for highspeed capillary gas chromatography. The quantitative analysis of a sample containing some eleven components in less than thirty seconds is shown.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Crystal hydrates as stationary phases ; Mobile Phases containing water ; Selective retentions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of crystallohydrates, crystallohydrate solutions and melts as stationary phases in gas chromatography has been proposed. Crystallohydrates have been shown to display high selectivity in the separation of polar organic compounds when use is made of water vapours as the mobile phase. Some aspects of gas-liquid chromatography in water vapours and with the stationary phase comprising crystallohydrates have been studied, and the preliminary results obtained point to the desirability of further progress in this field.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 201-203 
    ISSN: 1612-1112
    Keywords: Phenols ; Whisky ; Gas chromatography ; Aroma compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Twelve volatile phenols were identified in whisky by combined gas chromatography-mass spectrometry. Of these phenols 2,4-dimethylphenol was found for the first time in the aroma of whisky. The content of phenol, o-, m-, and p-cresol, guaiacol, p-ethylphenol, p-ethylguaiacol and eugenol in whiskies originating from different countries was determined by gas chromatography as their 2,4-dinitrophenyl ethers using electron capture detection. The results show that Scotch whiskies differ from others in the content of o-, m-, and p-cresol. The odour threshold values of phenols studied were determined in a 10% (v/v) ethanol-water mixture and in some cases also in the whiskies. Cresols have been found to make contribution to the aroma of Scotch whisky.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 26-31 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Ionization detectors ; Gaia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper is an account of the development of the gaia hypothesis as seen through the eyes of a gas chromatographer. Gaia is a radical notion about the Earth which postulates the climate and chemical composition to be regulated at an optimum by and for life. Gas chromatography played an important role in the gathering of evidence for the hypothesis but most significantly the art of inventing detectors lead to the developement of a planetary life detector through which gaia was revealed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 282-285 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Naphtha analysis ; Gasoline analysis ; Hydrocarbon type analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two different gas chromatographic methods are used for the determination of hydrocarbon type distribution in naphtha and gasoline samples with final boiling points up to 275 °C. The methods are based either on a single capillary column or on a valve-switched packed column system. Both methods give extensive information on paraffins, olefins, naphthenes and aromatics in total as well as by carbon-number. In each case the analysis is fully automated with a computer controlling the entire analysis from injection to results presentation. The advantages and limitations of both methods are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 322-324 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Graphitized carbon black supports ; Determination of hydroxyacids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Acid-washed graphitized carbon black (Carbopakc B) modified with trimesic adic and PEG 20M has proved to be effective for quantitative analysis of underivatized low molecular weight hydroxyacids. Calibration data revealed good linear relationships between relative peak area and concentration for lactic and 3-hydroxybutyric acids down to 0.05 mmol/l. The packing material was suitable for the analysis of aqueous solutions of hydroxyacids as it is tolerant to injections of water over a prolonged period of use. The GC system developed has been applied to the analysis of some hydroxyacids of biomedical interest in blood plasma and lactic acid contained in wine and beer.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Modified thermal energy analyzer ; Selective detection of nitrogen compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modification to the TEATM Analyzer is described, which allows it to be used as a highly selective GC detector for nitrogen compounds as well as for N-nitrosamines and nitro compounds. The modified Analyzer is as sensitive as the AFID, but has a much higher selectivity towards nitrogen compounds than the AFID. Its response appears to be molar, with an output that is dependent only on the number of nitrogen atoms present. The performance of the modified Analyzer for the analysis of ammonia, amines,N-nitrosamines, nitriles and organonitro compounds is reported and discussed, as is its application to the detection of these compounds in bacon and beer samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    ISSN: 1612-1112
    Keywords: Graphizized carbon black traps ; Organic air pollutants ; Work areas ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of traps containing graphitized carbon black for the collection and pre-analysis of atmospheric pollutants in industrial areas is presented. The working conditions, in terms of trapping capability and effectiveness of release by thermal desorption are discussed. Some practical applications are also given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Van der Waals' volume ; Polarity of stationary phase ; Retention index
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Equations for Retention Index (I) versus Van der Waals, volume (Vw) on squalane are studied for alcohols, carbonyls, esters and ethers. Each equation includes linear and branching substances with different positions of the functional group in the carbon chain. The study is extended to stationary phases with polarities from 4.29 to 91.54 on the Tarjan et al. scale. Variations of the slope and origin ordinate values with the polarity of the stationary phase are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 125-132 
    ISSN: 1612-1112
    Keywords: Capillary columns ; Fast analysis ; Gas chromatography ; Instrumental effects ; Optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The efficiency of fast GC columns depends largely on the quality of the chromatograph. A theoretical and experimental study shows the relative importance of the various phenomena involved and permits the optimization of a GC System. Extremely good performances, exceeding 2,500 plates per second have been routinely obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 180-182 
    ISSN: 1612-1112
    Keywords: Acidic fermentation products ; Characterisation ; Gas chromatography ; Methyl esters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid and simple method for the identification of acidic fermentation products is described. Methyl esters of volatile and non-volatile acids are separated on a single chromatographic column. Retention time data for a number of acids are tabulated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 521-524 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Connectivity index ; Van der Waals' volume ; Alkanes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The relationships between retention index and Van der Waals' volume and between retention index and connectivity index have been studied for 58 different alkanes (C1−C9) on squalane. The correlation coefficient for the former is higher than for the latter. From these equations a linear relationship between Van der Waals' volume and connectivity index is obtained which indicates that the two parameters are equivalent. A simple method for calculating the Van der Waals' volume of alkanes is proposed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Fused silica capillaries ; Capillary drawing ; Glass capillaries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A compact description is given of a simple and reliable method of drawing flexible fused silica capillary for gas chromatography. Some emphasis is given to the fact that the practices of drawing optical fibres should not be followed too slavishly so this leads to unnecessarily complicated and expensive equipment. Satisfactory capillary column silica tubing can be made with straightfoward extension of the method developed earlier for drawing thick walled capillary. A simple glass/silica hydrogen oxygen diffusion flame bumer is described for fusing the preform tubing at the draw point which is enclosed by a water cooled glass enclosure to trap evaporated silica and maintain the operation under dust free conditions. The uniformity of the capillary diameter is better than 5% which is adequate for most gas chromatographic purposes. The second part of the paper yet to be published will cover the methods developed for coating the capillary both internally and externally.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 107-111 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Thermionic ionization ; Catalytic flame ionization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A newly designed thermionic detector was operated in two modes of thermionic ionization detection (TID), and a third mode of catalytic flame ionization detection (CFID). Operating modes were varied by changing the composition of the electrically-heated thermionic/catalytic source, and the composition of gases supplied to the detector. A TID-2 source activated by a low concentration of Cs/ceramic was operated in a dilute H2/air environment and provided specific responses to nitrogen and phosphorus compounds. A TID-1 source activated by a high concentration of Cs/ceramic was operated in a N2 environment and provided very high specificities and picogram detectivities to compounds containing electronegative functional groups such as the NO2 group. A CFID source formed from Ni/ceramic was operated in a H2/air flame environment and provided universal responses to all organics with enhanced responses to some heteroatom compounds.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 19-22 
    ISSN: 1612-1112
    Keywords: Teflon columns ; Chemically modified teflon ; Gas chromatography ; Capillary columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Wall-coated open tubular columns prepared from chemically modified teflon tubing have been developed for gas chromatography. Chemical reaction of the inner walls of teflon tubing allows bonding of an adhesive layer on which a variety of stationary phaes can be coated. Test mixtures of alkanes and alcohols were used to investigate the chromatographic properties of these columns and the stability and mixing of the adhesive and stationary phae layers. the results in dicate that mixing of the layers is negligible and that the column is stable for a long period of time.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 55-66 
    ISSN: 1612-1112
    Keywords: Capillary columns, glass ; Gas chromatography ; Column preparation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Kapillar-Gas-Chromatographie ist heute das sich am stärksten entwickelnde Gebiet der Gas-Chromatographie. Es gibt viele komplexe, neue Fragestellungen in der Analytik, welche den Einsatz spezieller Kapillarsäulen erfordem. Glücklicherweise gibt es aber auch eine große Zahl von Herstellungsverfahren für Kapillarsäulen, welche — noch mehr als bei der Herstellung von gepackten Säulen — eine Anpassung an die gestellten Aufgaben ermöglichen. In diesem Artikel werden die Herstellungsverfahren für Kapillarsäulen zusammengestellt und Anregungen gegeben, wie aufgaben-orientierte Säulen erreicht werden.
    Notes: Summary Glass capillary column chromatography is the most rapidly growing part of gas chromatography. There are many complex new analytical tasks and they require special capillary columns, Fortunately there is a wide range of column preparation methods available, and they make the preparation of glass capillary columns a more varied job than that of packed columns. In this paper these methods are reviewed and suggestions are given for making task-oriented columns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Urea herbicides ; Catalytic hydrolysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the rapid catalytic hydrolysis of phenylurea herbicides on silica gel at elevated temperatures. After derivatisation of the anilines produced with heptafluorobutyric acid anhydride final analysis is done on a gas chromatograph equipped with an electroncapture detector. Detection limits are in the 1–5 picogram range. The method has successfully been applied to residue analysis of water samples at the 1 ppb level. The determination of free anilines present in water samples and the potential of various techniques to be used to discriminate between free anilines and parent herbicides are also discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Graphitised carbon black ; Phenols ; Water pllutants
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The fractionation of eleven phenols which may be contaminants in drinking water has been accomplished by using acid-washed graphitised carbon black modified with trimesic acid and PEG 20 M.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 447-451 
    ISSN: 1612-1112
    Keywords: Headspace analysis ; Gas chromatography ; Residual analysis of polyethylene terephthalate ; Acetylene reduction assay ; Ethylene evolution in germinating seed ; Acetaldehyde generation in polyester resin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary New application areas for headspace gas chromatography in agricultural and polymer degradation research are described. Specific examples are drawn from the various forms of headspace analysis with emphasis on the automated static equilibrium method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 576-578 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Tortuosity factor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The relationship between the obstructive factor γ and velocity was restudied. The dependence of the obstructive factor on velocity was verified. The effects of diffusion coefficient and particle-to-column diameter ratio on the obstructive factor-velocity relationship were investigated. The results are consistent with Hawkes' hypothesis that values of γ at low velocities are averages over tightly packed and loosely packed domains while at high velocities they are weighted in favour of the loosely packed domains where there is more flow.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 648-652 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Gas-liquid adsorption ; Bulk solution ; Mixed stationary phases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary It is shown that the blending of some retention effects can make the resolution of complex mixtures on short classical columns as effective as on capillary columns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 699-703 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Headspace analysis ; Aromatic hydrocarbons ; Water analyses
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The possibilities of using headspace analysis of aromatic hydrocarbon traces in aqueous solutions with changing values of the partition coefficients are discussed. A variant of headspace analysis of the simplest aromatic hydrocarbon in natural and waste water is described. It involves two-step gaseous extraction of a sample in vessels of varying volume before and after the equilibrium phase is replaced with a pure gas (air or nitrogen). This method permits to analyse 5–50 ml water samples with benzene and toluene contents varying from the ppb to the ppm range within an error not exceeding 155. The analysis time is about 1.5 h. The presence of non-volatile organic or mineral substances does not influence the determination. This method is unsuitable to heterogeneous systems (aqueous oil emulsions): before carrying out the analysis for the hydrocarbon content these systems have to be homogenized first.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open tubular (capillary) columns ; Glass columns ; Fused-silica columns ; Column testing
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Column characteristics affecting the chromatographic behavior of glass and siliceous glass (“fused silica”) capillary columns include the dimensional uniformity of the column, the physical and chemical characteristics of the column wall and the characteristics of the liquid phase. In the case of the coated column the uniformity and thickness of the liquid phase film are the most important criteria affecting column reproducibility. The paper discusses these factors and their influence on column performance.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 203-211 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Quantitative analysis ; Copper oxide converter ; Inorganic gas analysis ; Determination of fluorine and oxygen ; Hydrocarbon analysis ; Wine analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A review of past activities concerning selected industrial analytical problems is given. This includes the following question: preparation of pure gas mixtures to be used for calibration, catalytic conversion of ester and pyridin samples to carbon dioxide and a one-point calibration method using peak heights, both for quantitative analysis, analysis of gas mixtures containing fluorine and inorganic fluorine compounds and the determination of the oxygen and fluorine content of the sample, separation and identification of hydrocarbons in shale oil and petroleum fraction samples, and analysis of wine.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 143-147 
    ISSN: 1612-1112
    Keywords: Capillary columns ; Gas chromatography ; Retention index ; Structure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention index of twenty different homologous series of esters have been determined experimentally on polar (Carbowax 1540) and non-polar (squalane) columns. General equations to calculate retention index have been established by statistical methods. The influence of the length and inductive effect of acid and alcohol chains and the relative position of the carboxylic group are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 285-288 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Porous layer open tubular columns ; Kaolin as support ; Column performance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary PLOT columns have been prepared with kaolin as the liquid phase support. These columns show good efficiency with different stationary phases and good thermal stability with polar phases. The performance of columns is shown by the separation of various mixtures such as fatty acids, phenols and anilines which are of analytical importance.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 39-40 
    ISSN: 1612-1112
    Keywords: Xylidine isomers ; Heteroaromatic liquid phases ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Nicotinic acid and 1H-benzotriazole appreciably resolved all the xylidine (dimethylaniline) isomers, while benzimidazole, nicotinamide and phthalimide can also separate all the isomers except 2,4- and 2,3-xylidines. The analyses were carried out on supports which were not treated with an alkali.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...