Summary
Theoretical comparisons of various packed GC column types are presented with respect to analysis time, efficiency, sample dilution, and sample capacity for a given maximum inlet pressure. In particular, totally porous particles, porous layer beads, and glass beads are compared with one another. It is shown that 30 μm porous layer beads offer a useful compromise between analysis time and plate count with relatively good sample capacity. Moreover, when using 1 mm i.d. columns (microbore), outlet flow rates that are reasonable for direct coupling to magnetic sector mass spectrometers are achieved making these columns suitable for GC/MS. Using 30 μm Zipax porous layer beads, columns yielding 8,000 to 10,000 plates/meter have been produced with inlet pressures of 13 to 26 atm. A simple modification of the injection port converts the maximum inlet pressure of a commercial gas chromatograph to 26 atm. With such pressures, columns in excess of 20,000 plates can be achieved. Chromatograms are presented illustrating the promise of these microbore columns for GC and GC/MS analysis.
Similar content being viewed by others
References
S. R. Lipsky, W. J. McMurray, M. Hernandez, J. E. Purcell, K. A. Billeb, J. Chromatogr. Sci.18, 1 (1980).
V. Pretorius, T. W. Smuts, H.R.C. and C..C.2, 444 (1979).
F. Bruner, P. Ciccioli, E. Brancalleoni, A. Longo, Chromatographia8, 503 (1975).
J. F. K. Huber, H. H. Lauer, H. Poppe, J. Chromatogr.112, 377 (1975).
G. Guiochon, Anal. Chem.52, 2002 (1980).
L. Peichang, Z. Liangmo, W. Chinghai, W. Guanghua, X. Aizu, X. Fangbad, J. Chromatogr.186, 25 (1979).
R. Dandeneau, S. Hawkes, Chromatographia13, 686 (1980).
H. H. Lauer, H. Poppe, J. F. K. Huber, J. Chromatogr.132, 1 (1977).
H. V. Carter, Nature197, 684 (1963).
V. G. Berezkin, L. A. Shkolina, V. N. Lipavsky, A. A. Serdan, V. A. Barnov, J. Chromatogr.141, 197 (1977).
J. C. Sternberg, R. E. Poulson, Anal. Chem.26, 1492 (1964).
C. A. Cramers, J. A. Rijks, P. Bocek, J. Chromatogr.65, 29 (1972).
J. A. Rijks, C. A. Cramers, P. Bocek, Chromatographia8, 482 (1975).
C. A. Cramers, J. A. Rijks, Adv. in Chromatogr.17, 101 (1979).
F. Bruner, P. Cicocioli, G. Bentoni, J. Chromatogr.90, 239 (1974).
G. Guiochon, Adv. in Chromatogr.8, 179 (1969).
R. P. W. Scott, P. Kucera, J. Chromatogr.169, 51 (1979).
W. Virus, J. Chromatogr.12, 406 (1963).
M. N. Myers, J. C. Giddings, Anal. Chem.38, 294 (1966).
M. J. E. Golay, “Gas Chromatography 1960, Edinburgh”R. P. W. Scott (Ed.), Butterworths, London (1960), 439.
I. Halász, C. Horvath, Anal. Chem.36, 2226 (1964).
J. J. Kirkland, Anal. Chem.37, 1458 (1965).
M. Golay, Gas Chromatography 1959,D. H. Desty (Ed.) Butterworths, London (1958), 36.
L. R. Snyder, J. J. Kirkland, “Introduction to Moden Liquid Chromatography”, second edition, Wiley Interscienr (1976), 196.
J. H. Knox, M. Saleem, J. Chromatogr. Sci.7, 614 (1969).
B. L. Karger, M. Martin, G. Guiochon, Anal. Chem.46, 1640 (1974).
C. A. Cramers, J. A. Rijks, C. P. M. Schutjes, Chromatographia14, 439 (1981).
E. N. Fuller, P. D. Schettler, J. C. Giddings, Ind. and Eng Chem.58, 19 (1966).
D. A. Lewis, B.L. Karger, P. Vouros, in preparation.
S. P. Cram, F. J. Yang, Ind. Res./Dev., April (1978), 89.
F. A. J. M. Leemans, J. A. McClosky, J. Amer. Oil Chem Soc.44, 11 (1967).
D. L. Wall, A. W. Mantz, Applied Spectroscopy31, 551 (1977).
Author information
Authors and Affiliations
Additional information
Dedicated to Professor Dr. István Halász for his 60th birthday.
Rights and permissions
About this article
Cite this article
Lewis, D.A., Vouros, P. & Karger, B.L. High efficiency microbore GC columns using porous bead supports. Chromatographia 15, 117–124 (1982). https://doi.org/10.1007/BF02290444
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02290444