ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Spektralphotometrie, Atomabsorption  (90)
  • Chromatographie, Gas  (67)
  • Springer  (157)
  • Frontiers Media
  • 2015-2019
  • 1975-1979  (157)
  • 1940-1944
Collection
Keywords
Publisher
  • Springer  (157)
  • Frontiers Media
Years
Year
  • 1
    ISSN: 1618-2650
    Keywords: Analyse von Polycyclen in Lebensmitteln, Erdölprodukten, Abgasen, Tabakrauch ; Chromatographie, Gas ; gepackte Glassäulen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 100-101 
    ISSN: 1618-2650
    Keywords: Best. von Spurenelementen, Mangan, Kobalt in Serum ; Spektralphotometrie, Atomabsorption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 161-162 
    ISSN: 1618-2650
    Keywords: Nachw. von Hormonmetaboliten in Biolog. Gewebe ; Chromatographie, Gas ; Radio-GC
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 205-205 
    ISSN: 1618-2650
    Keywords: Best. von Schwermetallen in Wasser, Biolog. Material ; Spektralphotometrie, Atomabsorption ; verbesserter Gas-stop
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 280 (1976), S. 32-32 
    ISSN: 1618-2650
    Keywords: Best. von Äthylenglykol, Diäthylenglykol, Triäthylenglykol in Wasser ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 278 (1976), S. 121-124 
    ISSN: 1618-2650
    Keywords: Best. von Titan ; Spektralphotometrie, Atomabsorption ; Einfluß von Wertigkeit, Säuren, Liganden
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Der Einfluß der Wertigkeit des Titans, von Mineralsäuren und von verschiedenen organischer Komplexliganden auf die Ti-Absorption in N2O-Acetylen-Flammen wurde ausführlich untersucht. Die thermischen Prozesse in den trockenen Aerosolpartikeln scheinen für die Atomisierung wichtiger zu sein, als die Komplexbildungsgleichgewichte in der Lösung. In Gegenwart von Chromotropsäure ist die Titanbestimmung mit AAS empfindlicher und selektiver als bei der bisherigen Ausführung.
    Notes: Abstract The atomic absorption method for the determination of titanium in N2O-acetylene flames is studied from the point of view of the valence state of titanium, the effect of mineral acids and various organic complexing ligands in solution. It seems evident that the thermal procedures within the dry aerosol particle are rather more deciding for the atomisation processes than the complexation equilibria in solution. In the presence of chromotropic acid the sensitivity and selectivity of the method are increased in comparison with the usual procedure in pure solutions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 213-216 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Boden, Sedimenten ; Spektralphotometrie, Atomabsorption ; Flamme, Reextraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung In Vorversuchen wurde gezeigt, da\ beim Aufbewahren der organischen APDC/MIBK-Extrakte starke Bleiverluste auftraten. Daher war es notwendig, das Blei mit SalpetersÄure in die wÄ\erige Phase zu reextrahieren. Wiederfindungsversuche bestÄtigten, da\ Extraktion und Reextraktion quantitativ verlaufen. Das Blei wird dabei um den Faktor fünf angereichert. Es werden mittlere Standardabweichungen für vier Konzentrationsbereiche angegeben. Als Nachweisgrenze wurde eine Konzentration von 0,16 mg Pb/l gefunden, die durch die Anreicherung auf ca. 0,03 mg Pb/l gesenkt wird. Arbeitsvorschriften für das Verfahren sind angegeben.
    Notes: Summary Preliminary investigations have shown, that considerable losses of lead occur during storage of the organic APDC/MIBK-extracts. Therefore, it was necessary to reextract lead into the aqueous phase by nitric acid. Investigations of recoveries confirmed, that extraction and reextraction of lead were quantitative. In this way the concentration of lead is increased by a factor of five. Mean standard deviations for four concentration ranges are given. A detection limit of 0.16 mg of Pb/l is obtained, which is lowered by the preceding enrichment to about 0.03 mg of Pb/l. Details of the procedure are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 299-307 
    ISSN: 1618-2650
    Keywords: Analyse von Kohlenwasserstoffen in Luft ; Chromatographie, Gas ; Tieftemperaturgradientenrohr
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird über ein gas-chromatographisches Verfahren zur Bestimmung von Alkanen, Alkenen und Aromaten in der Außenluft berichtet, bei dem die Probenahme an Tenax GC oder Carbopack mit Hilfe eines Tieftemperaturgradientenrohres erfolgt und die Analyse unter Einsatz eines Doppelsäulensystems in Verbindung mit zwei Flammenionisationsdetektoren durchgeführt wird. Eingehende Untersuchungen zum Verhalten der Substanzen bei der Probenahme zeigen, daß die Trocknung der Probeluft mit Magnesiumperchlorat das Ergebnis nicht beeinflußt und für Kohlenwasserstoffe mit drei oder mehr C-Atomen keine auf Durchbruch zurückzuführenden Substanzverluste zu befürchten sind. Bei einem Probenahmevolumen von 51 Luft können 2 μg Substanz/m3 gut bestimmt werden. Für Außenluft-Konzentrationen von 45 μg Benzol/m3, 95 μg Toluol/m3 und 35 μg n-Pentan/m3 betrugen die Standardabweichungen 3,5, 6,0 bzw. 3,6 μg/m3. Bei leichter Modifikation des Systems ist mit derselben Probenahmevorrichtung die gleichzeitige Bestimmung von Kohlenwasserstoffen mit einem Flammenionisationsdetektor und von Organohalogen Verbindungen mit einem Elektroneneinfangdetektor möglich.
    Notes: Summary A method is described for the gas-chromatographic determination of alkanes, alkenes and aromatics in ambient air. The hydrocarbons are trapped by cryogenic sampling using Tenax GC or Carbopack as adsorbing material and are analyzed in a two-column system equipped with two flame-ionization detectors. A detailed examination of the sampling procedure shows that drying the air with magnesium perchlorate does not affect the results, and losses of substances due to break-through need not be reckoned with for hydrocarbons with three and more carbon atoms. In a 51 air sample 2 μg/m3 of hydrocarbons can be determined readily. The standard deviations for benzene, toluene and n-pentane were 3.5, 6.0 and 3.6 μg/m3 at ambient air concentrations of 45, 95 and 35 μg/m3. A slight modification of the system which includes the combined use of a flame-ionization detector and an electron-capture detector permits the simultaneous determination of hydrocarbons and halogenated hydrocarbons.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 345-351 
    ISSN: 1618-2650
    Keywords: Best. von Wismut, Cadmium, Thallium in Gesteinen ; Spektralphotometrie, Atomabsorption ; fraktionierte Destillation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The analysis of bismuth, cadmium and thallium in rock samples can be performed by flameless atomic absorption spectrometry, after separation and preconcentration by a volatilization technique. This method has the major advantage that small amounts of substance can be used with a minimum consumption of chemicals, so that sources of contamination are reduced. The detection limit for Bi and Tl is about 1 ppb and for Cd about 0.1 ppb in the rock. Depending on the content in the rock samples, the relative standard deviation is between 2 and 30%. Several attempts have been made to determine the yields of Bi, Cd and Tl from synthetic and natural samples.
    Notes: Zusammenfassung Die Bestimmung von Wismut, Cadmium und Thallium in Gesteinen kann mit der flammenlosen Atomabsorptions-Spektroskopie nach verdampfungsanalytischer Abtrennung erfolgen. Die Verdampfungsnalyse hat den Vorteil, daß bei geringem Reagentienverbrauch kleine Mengen analysiert werden können. Die Gefahr der Einschleppung von Verunreinigungen wird erheblich vermindert. Die Nachweisgrenze bezogen auf die Probe beträgt für Wismut und Thallium ca. 1 ppb und für Cadmium ca. 0.1 ppb. In Abhängigkeit von der Konzentration liegt die relative Standardabweichung zwischen 2 und 30 %. An synthetischen und natürlichen Proben sind die Ausbeuten an diesen Elementen bestimmt worden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 409-409 
    ISSN: 1618-2650
    Keywords: Analyse von Dimethylterephthalat ; Chromatographie, Gas ; Oxidationsgemisch
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 410-411 
    ISSN: 1618-2650
    Keywords: Analyse von 1,3,5-Trioxan ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 39-42 
    ISSN: 1618-2650
    Keywords: Analyse von Metaboliten in Biolog. Material ; Chromatographie, Gas ; Fraktionierung durch Extraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A new method for the gas-chromatographic multicomponent analysis of metabolites in biological material is described. It is an analytical procedure involving several extractions carried out under different conditions. In this procedure the metabolites are divided according to their functional groups and specific chemical behaviours into eight main fractions: lipids, hydrocarbons, organic acids, neutral substances, phenols, amines, amino acids and carbohydrates. Each of these fractions is derivatized; the components are separated and estimated by gas chromatography. This analytical system was applied to the determination of a number of metabolites in serum, urine, amniotic fluid, sperma, tissues and other biological materials.
    Notes: Zusammenfassung Eine Methode für die Multikomponenten-GC-Analyse von Metaboliten in Biomaterialien wird beschrieben. Das Verfahren umfaßt mehrere Extraktionen, die unter verschiedenen Bedingungen durchgeführt werden. Die Komponenten werden in Abhängigkeit von ihren funktionellen Gruppen und spezifischem chemischen Verhalten in acht Hauptfraktionen geteilt: Lipide, Kohlenwasserstoffe, organische Säuren, neutrale Substanzen, Phenole, Amine, Aminosäuren und Kohlenhydrate. Die Komponenten jeder Gruppe werden nach spezieller Derivatisierung gaschromatographisch getrennt und bestimmt. Dieses neue System ist bei verschiedenen biologischen Materialien (klinische Proben, Pflanzen- und Tiergewebe) angewandt worden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 295 (1979), S. 355-361 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Geolog. Material, Biolog. Material ; Spektralphotometrie, Atomabsorption ; Graphitrohrküvette
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Serious systematic errors inherent in the determination of lead in geological and biological samples by flameless atomic-absorption spectrometry are demonstrated. The reduced absorption of lead is due to partial interaction with alkaline, alkaline-earth and iron chlorides during the atomization stage. Incomplete dissociation of the volatile monochloride of lead in the gaseous phase reduces the absorption signal. An addition of 20% hydrogen to nitrogen (purge gas) diminishes signal suppression by removing the chlorine in form of volatile HCl. The detection limit is about 0.6 ppm in rocks and about 0.3 ppm in plant materials. Depending on the content in the samples the relative standard deviation is between 1 and 12%. The accuracy of the method was tested on 39 international standard reference samples.
    Notes: Zusammenfassung Schwerwiegende systematische Fehler bei der Bestimmung von Blei in geologischen und biologischen Materialien mit der Graphitrohrküvette werden aufgezeigt. Die Reaktion von Blei mit Alkali-, Erdalkali- und Eisenchloriden während der Atomisierungsphase führt zur Bildung von Bleimonochlorid, das nur unvollständig dissoziiert und eine Signalunterdrückung zur Folge hat. Ein Zusatz von 20% Wasserstoff zu Stickstoff als Spülgas vermindert die Signalunterdrückung, indem überschüssiges Chlor als Chlorwasserstoff entfernt wird. Die Nachweisgrenze liegt bei ca. 0,6 ppm für Gesteine und bei ca. 0,3 ppm für Pflanzenmaterialien. Je nach der Konzentration beträgt die relative Standardabweichung 1–12%. Die Genauigkeit der Methode wurde an 39 internationalen Standardreferenzproben überprüft.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 297 (1979), S. 117-120 
    ISSN: 1618-2650
    Keywords: Best. von Fluor ; Chromatographie, Gas ; F-spezifischer Detektor, Candoluminescenz
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein spektroskopischer fluor-spezifischer Detektor für gas-chromatographische (GC) Anwendungen beschrieben, der sich der Candoluminescenz bedient. Das Auftreten von InF-Bandenemissionen bei 233,7 nm bei Anwendung des MECA (= Molecular Emission Cavity Analysis)-Verfahrens kann als qualitatives Zeichen für die Anwesenheit von F in einer GC-Fraktion benützt werden. Nach entsprechender Kalibrierung kann die Bandenemission als Maß für die F-Konzentration in einer Fraktion dienen. Die Reproduzierbarkeit ist besser als ±2%, die Nachweisgrenze liegt bei 3,2 μg F pro Peak.
    Notes: Summary A fluorine-specific spectroscopical detector is described that takes advantage of candoluminescence. The intensity of the InF-band emission at 233.7 nm in Molecular-Emission-Cavity Analysis (MECA) is an indicator for F in a GC-fraction. After calibration the band intensity can be used as measure for the F-content in the fraction. The reproducibility is better than ±2%, the detection limit 3.2 μg F per peak.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 385-390 
    ISSN: 1618-2650
    Keywords: Best. von Carbonsäuren, Sulfonsäuren ; Chromatographie, Gas ; Spuren in wäßrigem Medium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Gas-chromatographische Methoden für die Spurenbestimmung einiger Carbonund Sulfonsäuren in wäßrigem Medium werden beschrieben. Die Nachweisvermögen für Ameisensäure, Essigsäure, Propionsäure, n-Buttersäure, n-Valeriansäure, Capronsäure, Acrylsäure, Benzoesäure und Chloressigsäure sowie für Methansulfonsäure und Äthansulfonsäure liegen zwischen 1 · 10−7 und 8 · 10−7 Mol/Liter. Anreicherung und Derivatisierung werden bei den Carbonsäuren durch Gefriertrocknung der Tetra-n-butylammoniumsalze und deren Umsetzung mit Benzylbromid zu den Benzylestern, bei den Sulfonsäuren durch Gefriertrocknung der Silbersalze und deren Umsetzung mit n-Butyljodid zu den n-Butylestern erreicht.
    Notes: Summary Gas-chromatographic methods for the determination of traces of several carboxylic and sulphonic acids in aqueous media are presented. Detection limits for formic, acetic, propionic, n-butyric, isobutyric, n-valeric, caproic, acrylic, benzoic, and chloroacetic acids as well as of methanesulphonic and ethanesulphonic acids range from 1 · 10−7 moles/liter to 8 · 10−7 moles/liter. Preconcentration and derivatisation of the carboxylic acids are achieved by freezedrying their tetra-n-butylammonium salts and converting the latter into the benzyl carboxylates using benzyl bromide. The sulphonic acids are converted to the corresponding silver salts, freeze-dried, and then esterified using n-butyl iodide.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 278 (1976), S. 365-366 
    ISSN: 1618-2650
    Keywords: Best. von Acetylsalicylsäureanhydrid, Acetylsalicylsalicylsäure in Acetylsalicylsäure ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 141-144 
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber in Zähnen, Knochen ; Spektralphotometrie, Atomabsorption ; HNO3/HF-Aufschluß, Kaltdampfverfahren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Verfahren zur Bestimmung von Quecksilber in Zahnwurzeln und Kieferknochen beschrieben. Die homogenisierten Proben werden in Teflonbomben unter Druck mit einem Gemisch von HNO3/HF aufgeschlossen. Die Quecksilberbestimmung erfolgt mit einem Atomabsorptionsspektrophotometer nach dem Kaltdampfverfahren. Unter Einsatz von 200 mg Probe können Quecksilbergehalte bis zu 0,1 μg/g bestimmt werden. Die relativen Standardabweichungen liegen im Arbeitsbereich von 10–100 ng Quecksilber zwischen 2,7 und 5,6 %. Es wurden Quecksilbergehalte von 〈0,1–187 μg/g in den Proben gefunden.
    Notes: Summary The homogenized samples are decomposed with a mixture of HNO3/HF in teflon vessels under pressure. The determination of mercury is carried out with an atomic absorption spectrophotometer by means of the cold-vapour technique. The limit of detection is 0.1 μg/g for a 200 mg sample. A relative standard deviation of 2.7–5.6% is achieved in the working range of 10–100 ng mercury. Mercury contents of 〈0.1–187 μg/g were found in the samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1618-2650
    Keywords: Analyse von Umweltmaterial, Pesticiden ; Chromatographie, Gas ; Capillar-, Ident. von Einzelkomponenten in komplexen Gemischen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Der Vergleich von präzise bestimmten Retentionsindices von Probe- und Referenzsubstanzen in der hochauflösenden Capillar-Gas-Chromatographie stellt eine aussagekräftige Methode der Identifizierung von Einzelkomponenten in komplexen Gemischen dar. Neben der Konstanz der GC-Parameter erfordert die präzise Bestimmung von Retentionsindices eine sehr genaue Bestimmung der Netto-Retentionszeiten. Insbesondere ist bei Anwendung einer Totzeitberechnung auf der Basis einer erzwungenen Linearisierung der log t s/Homologenzahl-Beziehung auf eine sehr genaue Retentionszeitmessung zu achten. Die Reproduzierbarkeit von präzise bestimmten Retentionsindices hängt von der Konstanz der Polarität und von der Adsorptivität der Capillarsäule ab. An ausreichend desaktivierten und konditionierten Hochleistungs-Capillarsäulen (TZ≥40) können unter der Voraussetzung einer Retentionszeit-Meßgenauigkeit von besser als 0,05% Retentionsindices über einen Zeitraum von mehreren Wochen innerhalb ±0,15 Indexeinheiten reproduziert werden. Eine Übertragung des n-Alkan bezogenen Retentionsindex-Konzeptes auf die homologe Reihe der n-Allkyl-trichloracetate (ATA) ermöglicht die Verwendung des Elektroneneinfang-Detektors (ECD) zur präzisen RetentionsindexBestimmung als Methode einer zuverlässigen Identifizierung von Substanzen im Picogrammbereich.
    Notes: Summary High resolution glass-capillary gas chromatography can be used as a powerful identification tool for single components in complex mixtures, when the matching of retention indices of reference compounds with those found in the sample is based on precise measurements. Besides the constancy of the GC-parameters high precision measurements of retention indices require an accurate determination of net retention times. Special care has to be taken for an accurate measurement of retention times when using a dead-time calculation on the basis of an enforced linearisation of the log t s/homologues-number relationship. The reproducibility of precise retention-index determinations strongly depends on the constancy of the polarity and on the adsorptivity of the capillary column. Provided a sufficiently deactivated and conditioned high performance capillary column (separation number ≥40) and an accuracy of retention-time measurement of better than 0,05 % retention indices can be reproduced within ±0.15 i.u. over a period of several weeks. A conversion of the n-alkane based retention-index concept to the use of the homologous series of n-alkyl-trichloro-acetates (ATA) allows the use of the electron-capture detector (ECD) for precise retention-index determinations for a reliable identification of compounds in the picogram range.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 412-413 
    ISSN: 1618-2650
    Keywords: Analyse von Dimethylterephthalat in Wasser ; Chromatographie, Gas ; Abwasser
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 385-390 
    ISSN: 1618-2650
    Keywords: Nachw. von Kohlenwasserstoffen, aromat. polycycl. in Wasser ; Chromatographie, Gas ; ECD, Anreicherungsverfahren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein einfaches und schnelles Adsorptionsverfahren zur Anreicherung von polycyclischen aromatischen Kohlenwasserstoffen (=PAK) wird angegeben: nach einer Magnesiumhydroxidfällung in der Wasserprobe wird der Niederschlag abzentrifugiert und durch Zugabe von Ammoniumchlorid gelöst; die organischen Substanzen in dieser Lösung werden mit sehr wenig Cyclohexan extrahiert, wodurch eine Einengung des Extraktes nicht erforderlich ist. Die PAK im Extrakt werden gas-chromatographisch mit ECD-Detektion getrennt. Ein Vergleich dieser neuen Methode mit der “rapid liquid extraction” wird beschrieben.
    Notes: Summary A simple and rapid adsorption method for the enrichment of polycyclic aromatic hydrocarbons (=PAH)is described: after precipitation of magnesium hydroxide in the water sample the precipitate is separated by centrifugation and then dissolved by adding ammonium chloride; the organic substances in this solution are extracted with a very small volume of cyclohexane. A concentration of the extract is not necessary. The PAH in the extract are, separated gaschromatographically using ECD detection. The new method is compared with the “rapid liquid extraction” method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 402-404 
    ISSN: 1618-2650
    Keywords: Best. von Antimon in Biolog. Material ; Spektralphotometrie, Atomabsorption ; Nanospuren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eine selektive Bestimmung von Antimon durch Atomabsorptionsspektrometrie ist durch elektrothermale Atomisierung von Antimonwasserstoff in einem Argonspülgasstrom möglich. Das Verfahren erfordert eine hohe und reproduzierbare Geschwindigkeit der Reduktion des Antimons zu Antimonwasserstoff in der wäßrigen Probelösung. Geeignete Bedingungen für diese Reduktion erreicht man, wenn man in der Lösung zunächst einen Komplex von Antimon(III) mit Äthylendiamintetraessigsäure bildet; dieser Komplex reagiert mit Natriumborhydrid in der geforderten Weise zu Antimonwasserstoff. Bei der Mineralisierung des organischen Materials ist auf genaue Temperaturführung zu achten.
    Notes: Summary High selectivity in measuring antimony by atomic absorption spectrometry is obtained by electrothermal atomisation of stibine in a stream of argon purging gas. This procedure requires a fast and reproducible reduction to stibine of the total antimony present in an aequeous solution. Optimum conditions for this reduction are reached by first transforming all antimony in the solution to an EDTA-chelate of antimony(III) which then reacts uniformly with sodium boron hydride to give stibine. Close temperature control is essential in decomposition of biological samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 416-416 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Benzin ; Spektralphotometrie, Atomabsorption ; emulgierte Proben
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 295 (1979), S. 110-115 
    ISSN: 1618-2650
    Keywords: Best. von Cadmium in Boden, Sedimenten ; Spektralphotometrie, Atomabsorption ; Zr-beschichtete Graphitrohre
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Verfahren beschrieben, das es gestattet, nach einer Anreicherung von Cadmium durch Extraktion mit APDC/MIBK und anschließender Reextraktion mit Salpetersäure, die stark salpetersaueren Reextrakte direkt in Zirkonium-beschichteten Graphitrohren bei Verwenden der flammenlosen Atomabsorption zu vermessen. Diese Rohre zeigten eine gute Lebensdauer (150–300 Analysen). Durch eine Behandlung der Rohre mit einer Fe3+-Lösung konnten Beeinflussungen der Cadmiumsignale durch Begleitstoffe verhindert werden. Cadmium wird bei der Extraktion und Reextraktion um den Faktor fünf angereichert. Bei hohen Cadmiumgehalten in den Proben kann die Analyse bei gleicher Probenvorbereitung mit Hilfe der Flammenatomabsorption durchgeführt werden. Die Arbeitsbedingungen für die flammenlose, sowie für die Flammen-Atomabsorption werden angegeben. Als Nachweisgrenzen bei Verwenden der flammenlosen Atomabsorption wurden im Mittel 0,53 μg Cd/l, für die Flammenatomabsorption 19,4μg Cd/l gefunden, die durch die Anreicherung auf ca. 0,1, bzw. 4 μg Cd/l gesenkt werden.
    Notes: Summary Cadmium is enriched by an extraction with APDC/MIBK and subsequent reextraction with nitric acid. A procedure is described for analyzing these solutions directly by means of flameless atomic absorption, inspite of the high concentration of nitric acid in a zirconium coated graphite tube. These tubes, proved to be very resistant (150–300 analyses). After treatment of the tubes with a Fe3+-solution no interference by accompanying anions and cations could be observed. By the extraction and reextraction procedure described cadmium is enriched by a factor of five. Samples of higher cadmium concentrations were analyzed by means of flame atomic absorption after the same sample preparation. Working conditions for flameless and flame atomic absorption are given. Detection limits have been calculated as 0.53 μg Cd/l in the case of flameless, 19.4 μg Cd/l in the case of flame atomic absorption. These values are further decreased by the above enrichment procedure to 0.1 and 4 μg Cd/l, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber, Silber, Kupfer, Wismut, Blei, Cadmium, Tellur in Wasser ; Röntgenfluorescenz-Spektrometrie ; Spektralphotometrie, Atomabsorption ; Spuren, Anreicherung an Sulfidschichten, Fällungsaustausch
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur Verbesserung des Nachweisvermögens und der Zuverlässigkeit von röntgenfluorimetrischen und atomabsorptiometrischen Bestimmungsverfahren für geringe Spurengehalte von Hg, Ag, Cu, Bi, Pb, Cd, Sn, As, Se, Te, Zn, Co und Ni in wäßrigen Lösungen wurde die Eignung einer der Bestimmung vorgeschalteten Anreicherungsmethode durch Fällungsaustausch an einer dünnen Sulfidschicht systematisch untersucht. Die wäßrige Probe (0,1–61, pH 3–6) wird durch eine auf einem Membranfilter (Cellulosenitrat bzw. PTFE, Porenweite ≤1 μm) frisch präparierte homogene Metallsulfidschicht (ZnS, MnS, CuS, PbS u.a., Dicke: 300–400 nm) filtriert. Dabei werden mit Ausnahme des Arsens die Elemente praktisch vollständig aus der Lösung zurückgehalten, die schwerlösliche Sulfide mit einem kleineren Löslichkeitsprodukt als das der austauschenden Schicht bilden. Nach dem Austausch kann die Bestimmung der Elemente entweder simultan durch RFA direkt auf dem Filter oder nach Lösen des Niederschlages in wenig Säure durch AAS mit elektrothermischer Atomisierung erfolgen. Durch erhebliche Voranreicherung können Nachweisgrenzen im ng/l-Bereich erzielt werden. Eichung, Störungen durch Begleitsubstanzen und Güteziffern des Verbundverfahrens werden beschrieben, das vor allem für die simultane und zuverlässige Bestimmung von Spuren, Hg, Ag, Cu, Bi, Pb, Cd und Te in Trink-, Oberflächen- und Schneeschmelzwasser empfohlen werden kann.
    Notes: Summary For the improvement of the power of detection and the reliability of X-ray fluorimetric and atomic-absorption spectrometric determination procedures for very low levels of Hg, Ag, Cu, Bi, Pb, Cd, Sn, As, Se, Te, Zn, Co and Ni in aqueous solutions the applicability of a pre-concentration method by precipitate-exchange on thin sulphide layers which preceds the actual determination has been investigated systematically. The aqueous sample (0.1–61, pH 3–6) is filtered through a freshly prepared homogeneous metal sulphide layer (e.g. ZnS, MnS, CuS, PbS, thickness: 300–400 nm) which is placed on a membrane filter (cellulose nitrate or PTFE, pore size ≤1 μm). In this way with the exception of As, the elements forming sparingly soluble sulphides with a lower solubility product than the corresponding sulphides of the layer are practically completely retained from the solution. The exchanged elements can be determined either simultaneously directly on the filter by RFA or sequentially after dissolution of the precipitate in a small volume of acid by AAS with electrothermal atomization. By a considerable pre-concentration detection limits in the ng/l range can be obtained. Calibration, interferences by concomitant elements, and quality grades of the multi-stage procedure are described, which can be recommended for the simultanous and reliable determination of traces of Hg, Ag, Cu, Bi, Pb, Cd, and Te in potable, surface, and snow-melting water.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 295 (1979), S. 352-354 
    ISSN: 1618-2650
    Keywords: Best. von Kupfer mit Zinkdibenzyldithiocarbamat ; Spektralphotometrie, Atomabsorption ; Lösungsmittel für die Extraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The utility of various organic solvents, such as acetates and ketones, for the CuDBC chelate extraction and subsequent atomic absorption spectrophotometric determination is studied. Methyl propionate was found to be the most sensitive solvent. Data for the different substances are presented.
    Notes: Zusammenfassung Die Verwendbarkeit verschiedener Lösungsmittel (Acetate und Ketone) für die Extraktion des CuDBC-Komplexes und anschließende atomabsorptions-spektralphotometrische Bestimmung wurde systematisch untersucht. Werte für die verschiedenen Substanzen werden angegeben. Die größte Empfindlichkeit kann mit Methylpropionat erzielt werden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 282-284 
    ISSN: 1618-2650
    Keywords: Best. von Wismut in Aluminiumlegierungen, Lötlegierungen ; Spektralphotometrie, Atomabsorption ; Zinkdibenzyldithiocarbamat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A sensitive method for the extraction and atomic-absorption spectrometric determination of bismuth with zinc dibenzyldithiocarbamate (ZnDBC) has been developed for aluminium alloys and solder alloys. Bismuth is extracted from relatively strong acidic solution into methyl isobutyl ketone (MIBK) as BiDBC complex and its concentration is determined by spraying the MIBK extract into an air-acetylene flame. Iron and copper up to 1 mg resp. 100 μg did not interfere with the extraction of bismuth in the range of 0–80 μg. The limit of detection was about 0.12 ppm in MIBK.
    Notes: Zusammenfassung Ein empfindliches Verfahren zur Wismutbestimmung mit Zinkdibenzyldithiocarbamat wurde ausgearbeitet. Wismut wird dabei aus relativ stark saurer Lösung als Bi-DBC-Komplex mit Methylisobutylketon extrahiert und zur Messung der Extrakt direkt in die Luft-Acetylen-Flamme gesprüht. Bis zu 1 mg Fe und 100 μg Cu stören die Bestimmung von 0–80 μg Bi nicht. Die Nachweisgrenze beträgt 0,12 ppm in Methylisobutylketon.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber ; Spektralphotometrie, Atomabsorption ; Kaltdampf, Vergleich der Reduktion mit NaBH4-Tablette oder SnCl2-Lösung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An atomic-absorption spectrophotometric method for the rapid and precise determination of mercury has been studied by using the sodium borohydride tablet reduction and cold-vapour atomicabsorption procedure coupled with amalgamation on gold. The comparison of the sodium borohydride tablet and tin(II) chloride solution reducing systems are described in detail. The use of the sodium borohydride tablet wrapped in a wafer sheet is very simple and gives more precise results. From the comparison of the effect of diverse ions, it is obvious that both reducing systems have their merits and demerits.
    Notes: Zusammenfassung Ein atomabsorptions-spektralphotometrisches Kaltdampf-Verfahren zur schnellen Quecksilberbestimmung wird beschrieben, das auf der Reduktion mit Hilfe der Natriumborhydridtablette und der Amalgamierung mit Gold beruht. Der Vergleich mit der Zinn(II)-Chloridmethode wird diskutiert. Genaue Ergebnisse werden durch einfaches Einhüllen der Reduktionstablette in ein Waffelblatt erzielt, wodurch der Reaktionsbeginn verzögert wird. In bezug auf Störelemente ergeben sich für beide Verfahren Vor- und Nachteile.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 278-281 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Algen, Diatomeen ; Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird eine nasse HF-HClO4Veraschungsmethode von biologischem Material in offenen PTFE-Reagensgläsern beschrieben. In anschließenden flammenlosen AAS-Messungen mit Hilfe der Deuterium-Untergrundkompensation und des automatischen Probenwechslers AS-1 konnte gezeigt werden, daß Silicium vollständig entfernt worden, kein meßbarer Matrix-Effekt festzustellen war und die Bleikonzentrationsbestimmung durch eine Eichgerade und durch Standard-Addition zu gleichen Werten führte. Die Methode ist mit einem Variations-Koeffizient von 0,45% behaftet.
    Notes: Summary A wet HF-HClO4 decomposition method for biological material in open PTFE-test-tubes is described. Flameless AAS measurements with the aid of deuterium background compensation using the auto sampling system AS-1 showed that Si was completely eliminated by the decomposition, that no measurable matrix effect could be detected, and that the values found for the lead concentration by calibration curve and standard addition were identical. The coefficient of variation for the method was V=0.45%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 362-364 
    ISSN: 1618-2650
    Keywords: Best. von Siliciumorganoverbindungen in Wasser ; Spektralphotometrie, Atomabsorption ; Extraktionsverfahren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An extraction technique is described for the determination of ppm concentrations of both hydrophobic and hydrophilic methylsiloxane compounds in water, based on a single extraction with a mixed solvent of (1∶1) l-pentanol and methyl isobutyl ketone followed by the determination of the silicone compounds extracted into the mixed solvent by atomic absorption spectroscopy. The method is applicable over the concentration range 0.3–30 ppm Si. Standard deviation in the case of 10 ppm Si is 0.313.
    Notes: Zusammenfassung Zur Bestimmung von ppm-Konzentrationen an hydrophoben und hydrophilen Methylsiloxanverbindungen im Wasser wird ein Extraktionsverfahren beschrieben. Hierbei wird nach einfacher Extraktion mit l-Pentanol/Methylisobutylketon (1∶1) das Silicium im Extrakt mit Hilfe der AAS bestimmt. Der erfaßbare Konzentrationsbereich liegt bei 0,3–30 ppm Si. Die Standardabweichung beträgt bei 10 ppm Si 0,313.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 298 (1979), S. 9-11 
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber in Luft ; Spektralphotometrie, Atomabsorption ; neues Spektrometer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein Atomabsorptions-Spektrometer wird beschrieben, das zur Bestimmung des Quecksilbergehaltes in Luft die Absorption der im vakuumultravioletten Spektralbereich gelegenen Hg-Resonanzlinie 184,9 nm benutzt. Die Kombination einer Hg-Niederdruckdampflampe mit einer Photozelle mit CsI-Kathode gestattet einen Spektrometer-Aufbau ohne Monochromator oder Filter. Zur Messung der HgKonzentration in Gasen wird das Quecksilber einer Probe zunächst auf einem Goldblech gesammelt, durch Ausheizen des Goldes wieder freigesetzt und die Absorption durch die Dampfwolke bestimmt. Das Eichverfahren und Meßbeispiele werden erläutert.
    Notes: Summary An atomic absorption spectrometer is described using the absorption of the vacuum ultraviolet resonance line 184.9 nm to determine the amount of mercury in air. The use of a mercury low-pressure discharge lamp combined with a CsI photocell makes it possible to omit monochromator or filter. For measuring the concentration of mercury in all sorts of gases the mercury of the sample is collected on sheet gold. By heating the sheet mercury is set free and the absorption of the mercury vapour can then be measured. The calibration procedure and some analytical results are described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 298 (1979), S. 45-46 
    ISSN: 1618-2650
    Keywords: Best. von Barbituraten, Phenytoin in Harn ; Chromatographie, Gas ; Hg-Verbindungen v. Barbituraten
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 11-15 
    ISSN: 1618-2650
    Keywords: Best. von Blei neben Wismut ; Chromatographie, Gas ; Di(trifluoräthyl)dithiocarbamat. — Verhalten von Kupfer(II), Nickel(II), Kobalt(III), Eisen(III), Wismut(III), Blei(II), Antimon(III) ; Verteilung zwischen wäßriger Lösung und Chloroform
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Das Verteilungsverhalten der oben genannten Di(trifluroäthyl)dithiocarbamato-Chelate zwischen wäßrigen Lösungen und Chloroform wird untersucht. Eine Anwendung zur gleichzeitigen gaschromatographischen Bestimmung von Blei und Wismut im ppm-Bereich (0,2–3 ppm) nach Ausschütteln aus wäßrigen Lösungen wird beschrieben (Säule: 5 % GE SE50 auf Gas Chrom Q; 180–240° C; 4°/min; Einspritzblock: 240° C).
    Notes: Summary The solvent extraction of the above di(trifluoroethyl)dithiocarbamatochelates with chloroform is investigated. An application for the simultaneous gas-chromatographic determination 0.2–3 ppm of lead and bismuth after extraction out of aqueous solutions is reported (column: 5% GE SE 50 on Gas Chrom Q; 180–240° C; 4°/min; injection block: 242°C).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 277 (1975), S. 124-124 
    ISSN: 1618-2650
    Keywords: Pantothensäure, Pantolacton ; Chromatographie, Gas ; Hydrolyse von Coenzym A
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 125-127 
    ISSN: 1618-2650
    Keywords: Best. von Phosphor in Stahl ; Spektralphotometrie, Atomabsorption ; flammenlos, ZrC-beschichtete Graphitrohrküvette
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A flameless atomic-absorption method for determination of phosphorus is developed, employing zirconium treated graphite tubes. The great improvement of the sensitivity with these tubes eliminates the necessity of adding La(NO3)3. The sensitivity does not vary from tube to tube and its maximal value is attained within the first 2–3 firings. The atomization signal is practically the same within the range of 2,600–2,800° C when the rise of the temperature is high (〉 1,500° C/s). The best signal to noise ratio is obtained at 2,600° C. The detection limit is 0.05 ppm with injection of 50 μl. The method is applied to the analysis of a standard steel sample.
    Notes: Zusammenfassung Durch Verwendung einer ZrC-beschichteten Graphitrohrküvette wurde eine wesentliche Erhöhung der Empfindlichkeit erzielt, ohne daß eine Zugabe von La(NO3)3 nötig wäre. Bei Küvettenwechsel ändert sich die Empfindlichkeit nicht. Das maximale Signal wird während der ersten 2–3 Bestimmungen erreicht. Das Atomisierungssignal bleibt im Bereich zwischen 2600 und 2800 °C praktisch unverändert. Das Signal/Rausch-Verhältnis ist bei 2600 °C am größten. Die Nachweisgrenze beträgt 0,05 ppm bei 50 μl. Die Methode wurde zur Analyse von Stahlstandardproben angewendet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 277 (1975), S. 9-17 
    ISSN: 1618-2650
    Keywords: Ermittlung des Vernetzungsgrades, Beladungszustandes von Ionenaustauschern ; Chromatographie, Gas ; Pyrolyse, Kunstharzbasis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur besseren Reproduzierbarkeit der Zusammensetzung des Pyrolysates bei der Pyrolyse-Gas-Chromatographie wird eine spezielle Eingabenanordnung mit Trägergasumschaltung beschrieben und deren Einfluß auf die Bildung der Pyrolyseprodukte und auf die Retentionszeiten mit einer Modellsubstanz untersucht. Mit Hilfe der Trägergasumschaltung kann man die Bandenflächenverhältnisse zur Bestimmung des Vernetzungsgrades von Ionenaustauschern auf Styrol-DVB-Basis wesentlich genauer ermitteln. Da bei der Pyrolyse von Anionenaustauschern wenigerα-MSt auftritt als bei den Kationenaustauschern, sind die Bandenflächenverhältnisse bei ersteren wesentlich größer. Bei den Anionenaustauschern werden sie mit steigendem Vernetzungsgrad kleiner, wohingegen bei den Kationenaustauschern die Werte steigen. Bei 400° C erfolgt der thermische Angriff im wesentlichen an der aktiven Gruppe der Anionenaustauscher mit Styrol-DVB-Matrix. Die aus dem Gegenion entstehenden Methylester bzw. deren Zersetzungsprodukte sind charakteristische Pyrolyseprodukte. Kennzeichnend für Dowex 1 ist das Auftreten von Trimethylamin, für Dowex 2 das von Acetaldehyd. Somit ist es mit der Pyrolyse-Gas-Chromatographie möglich, zusätzlich zur Matrix, Art und Struktur der funktionellen Gruppe sowie Substitutionsstelle der Ankergruppen an der Matrix auch Vernetzungsgrad und Beladungszustand von Ionenaustauschern zu ermitteln.
    Notes: Abstract A special introduction device with switching of carrier gas for improving the reproducibility of pyrolysate composition in pyrolysis gas-chromatography has been described. Its influence on the formation of pyrolysis products and on retention times has been studied on a model substance. The peak area ratios for determining the degree of cross-linking in ion exchangers on styrene-DVB basis can be estimated considerably more accurately with the help of carrier gas switching. Since anion exchangers yield lessα-methylstyrene on pyrolysis than do cation exchangers, their peak area ratios are appreciably larger. Increasing the degree of cross-linking lowers the ratios with the anion exchangers and raises them with the cation exchangers. At 400° C the thermal attack on anion exchangers with styrene-DVB matrix occurs mainly at the active group. The methyl esters or their decomposition products formed from the counter ions are characteristic pyrolysis products. A feature of Dowex 1 is the formation of trimethylamine; of Dowex 2, acetaldehyde. In this way, pyrolysis gas-chromatography enables information about the degree of cross linking and the nature of the anion of ion exchangers, as well as about the matrix, type and structure of the functional group and position of substitution of the anchor group in the matrix to be obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 277 (1975), S. 31-32 
    ISSN: 1618-2650
    Keywords: Best. von Benzol ; Chromatographie, Gas ; ultrapolare Mischphasen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 1-17 
    ISSN: 1618-2650
    Keywords: Chromatographie, Gas ; Anwendung der Subtraktionsmethode, Übersicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The fundamental principles of the subtraction method and its practical application in gas chromatography are discussed. Its use for identifying components of complex mixtures and analysing impurities is explained in detail and prospects for further development of the method are outlined. 136 Literature references.
    Notes: Zusammenfassung Ein Überblick über die Grundlagen der Subtraktionsmethode und ihre praktische Anwendung in der Gas-Chromatographie wird gegeben. Die Anwendbarkeit zur Identifizierung der Bestandteile komplexer Gemische und zur Analyse von Verunreinigungen wird eingehend diskutiert. Abschließend wird die mögliche weitere Entwicklung der Methode betrachtet. 136 Literaturzitate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 345-349 
    ISSN: 1618-2650
    Keywords: Best. von Kupfer, Blei, Zink ; Spektralphotometrie, Atomabsorption ; Flamme, chromatogr. Trennung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The sample of seawater (51) is freed from solid particles, buffered at pH 5.6 and percolated through a column filled with ED3A. After sample passage 15 ml 1 M hydrochloric acid solution are pumped through the column to dissolve the concentrated ions. The final measurement using flame atomic absorption is carried out in the hydrochloric acid solution. The total labour time is less than 15 min. The standard deviations (4 analyses) for the determination of Cu, Pb and Zn (in the normal concentration range of 2–6 μg · l−1) were 2–5%, 5% and 1–10%, the recoveries 100%, 102% and 104%, respectively. A concentration coefficient of 300–500 was obtained.
    Notes: Zusammenfassung Die Probe Meereswasser (51) wird nach Entfernen der festen Teilchen auf einen pH-Wert von 5,6 gepuffert und durch eine Trennsäule mit ED3A geführt. Die angereicherten Metallionen werden mit 15 ml 1 M HCl-Lösung eluiert. Anschließend erfolgt die Bestimmung durch Flammenatomabsorption. Die Methode erfordert insgesamt weniger als 15 min Arbeitszeit. Die Standardabweichungen (4 Best.) betragen für Cu, Pb und Zn (im normalen Bereich von etwa 2–6 μg·l−1) etwa 2–5%, 5% und 1–10%, die Wiederfindungsraten 100%, 102% bzw. 104%. Der Konzentrationskoeffizient beträgt 300 bis 500.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 135-139 
    ISSN: 1618-2650
    Keywords: Best. von Chrom ; Spektralphotometrie, Atomabsorption ; Störung durch Fremdelemente
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The interfering effect of thirty six metal salts on chromium absorbance in the air-acetylene flame has been studied. The interference does not depend on the boiling point of the added foreign metals or particle size as previously assumed but is postulated to result from the formation of mixed oxides or bimetallic species or from suppression of ionized gaseous chromium pressure. The effect of the alkali sulphates as releasing agents in the determination of chromium has been tested and results show that they can be used to eliminate both suppressive and enhancing interferents.
    Notes: Zusammenfassung Die Störungsmöglichkeiten von 36 verschiedenen Metallsalzen bei der AAS-Bestimmung von Chrom mit Hilfe der Luft-Acetylen-Flamme wurden systematisch untersucht. Dabei stellte sich heraus, daß der Einfluß dieser Salze nicht — wie früher angenommen — vom Siedepunkt der betreffenden Metalle oder der Teilchengröße abhängt, sondern von der Bildung von Mischoxiden, Bimetallverbindungen oder von der Herabsetzung des Chromdampfdrucks. Weiterhin wurde die Wirkung von Alkalisulfaten als Releasing-Reagentien untersucht und gefunden, daß diese sowohl bei abschwächender als auch verstärkender Wirkung angewendet werden können.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 128-134 
    ISSN: 1618-2650
    Keywords: Best. von Chrom ; Spektralphotometrie, Atomabsorption ; Arbeitsbedingungen, Einflüsse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wurde die Vielfältigkeit der Einflüsse von Mineralsäuren, Lösungsgenossen, Brennererwärmung und der Wertigkeit des Ions, welche insgesamt die Bestimmung von Chrom mittels AAS sehr problematisch gestalten, systematisch untersucht. Durch Verwendung einer brenngasarmen Acetylen-Lachgasflamme werden diese Schwierigkeiten weitestgehend beseitigt, was an hochprozentigen Normstählen demonstriert wird.
    Notes: Summary The variety of influences, such as mineral acids, heating of the burner head, solvent components and valency of the ion, was examined systematically. By use of a lean acetylene-nitrous oxide flame these difficulties can by eleminated extensively, and this is demonstrated on high chromium standard steels.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 159-160 
    ISSN: 1618-2650
    Keywords: Best. von Lithium ; Spektralphotometrie, Atomabsorption ; Graphitrohrküvette, Isotopie-Effekte
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 337-344 
    ISSN: 1618-2650
    Keywords: Best. von Selen ; Spektralphotometrie, Atomabsorption ; Spuren, Hydrid, Elementquerstörungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Natriumborhydrid-Reduktionsmethode zur Austreibung des Selens aus sauren Probenlösungen in Kombination mit einer AAS-Bestimmung des Selens in einer geheizten Quarzküvette (Hydridsystem MHS-1 der Firma Bodenseewerk Perkin-Elmer, Überlingen) wird durch die Gegenwart zahlreicher Begleitelemente selbst im Spurenbereich gestört. Bei der Bestimmung von 5–100 ng Se in 20 ml 0,3 N salzsaurer Probenlösung verursachen ca. 0,7 μg Ag+;1,5 μg Sb3+;3 μg Au3+; 5 μg Cu2+; 6 μg As3+; 25 μg Sb5+; 30 μg As5+; 60 μg Ni2+; 200 μg Pt4+ bzw. Mn7+; 700 μg Co2+; 1,5 mg Pb2+; 3 mg Cr6+ und 5 mg Hg2+ jeweils Erniedrigungen des Se-Signals um 50%. 4 μg Sn2+/Sn4+ bzw. 6 μg Bi3+ führen zu einer 30 %igen Erniedrigung. Fe2+/Fe3+ stören ab Mengen ≥400 μg. Te4+ ≤ 300 μg, Alkali- und Erdalkalimengen≤25 mg sowie Mengen ≤ 5mg Al3+, Cr3+, Mn2+ und Zn2+ waren ohne Einfluß auf die Ausbeute der Selenhydrid-Bildung. Die Störungen sind stark abhängig von der vorgegebenen HCl-Konzentration in der Probenlösung. Weitere Quellen für systematische Fehler des Verfahrens wurden untersucht und teilweise behoben. Das Hydrid-AAS-Verfahren kann nicht zur direkten Bestimmung von Selenspuren (ng/g-Bereich) in metallischen, geologischen und biologischen Matrices empfohlen werden, wenn die Gehalte der störenden Begleitelemente in der Probe bestimmte Grenzkonzentrationen überschreiten, die numerisch stark von der apparativen Anordnung und den Versuchsparametern abhängen.
    Notes: Summary The sodium boro hydride-reduction method for the liberation of selenium from acid sample solutions in connection with its determination by AAS using a heatable optical cell made of quartz (hydride system MHS-1, Bodenseewerk Perkin-Elmer, Überlingen, F.R.G.) is interfered with by numerous concomitant elements occurring even in the trace range in the sample solution. In the determination of 5–100 ng of selenium in 20 ml sample solution 0.3 N in HCl, 0.7 μg of Ag+; 1.5 μg of Sb3+; 3 μg of Au3+; 5 μg of Cu2+; 6 μg of As3+;25 μg of Sb5+; 30 μg of As5+; 60 μg of Ni2+; 200 μg of Pt4+ and Mn7+; 700 μg of Co+; 1.5 mg of Pb2+; 3 mg of Cr6+ and 5 mg Hg2+ cause a depression of the Se-signal of 50%. 4 μg of Sn2+/Sn4+ and 6 μg of Bi3+ cause a depression of 30%. Fe2+ /Fe3+ interfere only if present in quantities ≥400 μg. Te4+ in quantities ≤300 μg, alkali metals and alkaline earths ≤25 mg, and Al3+, Cr3+, Mn2+ and Zn2+ ≤5 mg do not affect the selenium hydride formation. The interferences depend very strongly on the used HCl concentration in the sample solution. Further sources of systematic errors are investigated and partly eliminated. The hydride-AAS procedure cannot be recommended for the determination of traces of selenium (ng/g-range) directly in metallic, geological or biological matrices, if the levels of the interfering concomitants reach above a certain threshold concentration, which numerically depend strongly on the apparatus and the parameters of the analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 374-376 
    ISSN: 1618-2650
    Keywords: Best. von Cadmium in Aluminium ; Spektralphotometrie, Atomabsorption ; Verflüchtigung aus Reinstaluminium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Verfahren zur Bestimmung kleinster Mengen Cadmium beschrieben, bei dem Cadmium zunächst aus Reinstaluminium verflüchtigt und dann im Wasserstoffstrom entweder on-line oder off-line mit der flammenlosen AAS bestimmt wird. 23 ppb Cadmium konnten bestimmt werden.
    Notes: Summary A method is described for the determination of low concentrations of cadmium. In the first step cadmium is volatilized out of very pure aluminium and subsequently determined in a H2 stream either off-line or on-line with flameless AAS. 23 ppb of cadmium could be determined.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 377-379 
    ISSN: 1618-2650
    Keywords: Best. von Arsen in Blei, Bleilegierungen ; Spektralphotometrie, Atomabsorption ; Red. zu Arsin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Verfahren zur Bestimmung von μg/g- bis mg/g-Gehalten Arsen in Blei und Bleilegierungen beschrieben. Das Arsen wird dazu mit NaBH4 als AsH3 aus der Probenlösung ausgetrieben und atomabsorptions-spektrometrisch in einer geheizten Quarzküvette bestimmt. Durch geeignete Arbeitsbedingungen werden Störungen durch die Matrix ausgeschaltet. Für den gesamten Arbeitsbereich beträgt die relative Standardabweichung etwa 3% (N=12); die Nachweisgrenze (3 σ-Grenze) wurde zu 0,1 μg/g As ermittelt.
    Notes: Summary A method is described for the determination of μg/g to mg/g concentrations of As in lead and lead alloys. For that purpose arsenic is blown out from the sample solutions as AsH3 by use of NaBH4 and determined by AAS in a heated quartz cuvette. Using suitable conditions disturbances caused by the matrix are eliminated. The relative standard deviation over the whole working range is about 3% (N=12); the detection limit (3 σ) was found to be 0.1 μg/g As.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 277 (1975), S. 19-24 
    ISSN: 1618-2650
    Keywords: Best. von Silber, Cadmium, Blei, Zink in Wasser ; Spektralphotometrie, Atomabsorption ; flammenlos, Ta-Streifen ; Best. von Zink neben Albumin in Serum ; Spektralphotometrie, Atomabsorption ; flammenlos, Ta-Streifen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A simple and efficient tantalum strip atomizer is described suitable for use in the atomic absorption determination of trace elements in water. The cell operates with an inexpensive Powerstat-transformer unit to provide the necessary electrothermal heat for atomization. It can be easily fitted in the place of the burner in atomic absorption instruments. The atomizer has been used to determine Ag, Cd, Pb, and Zn in tap water samples and Zn in the presence of albumin.
    Notes: Zusammenfassung Die elektrische Erhitzung des Tantalstreifens wird mit Hilfe einer preisgünstigen Energiequelle (Powerstat/Transformator) vorgenommen, die leicht anstelle des Brenners in den üblichen Geräten untergebracht werden kann. Das Verfahren wurde zur Bestimmung von Ag, Cd, Pb und Zn in Leitungswasser sowie von Zink neben Albumin angewendet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 114-124 
    ISSN: 1618-2650
    Keywords: Best. von Spurenelementen, Schwermetallen in Wasser ; Spektralphotometrie, Atomabsorption ; Bodensee
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Monatliche AAS-Messungen im Jahre 1977 auf die Elemente As, Pb, Cd, Cr, Hg, Se, Zn, Fe, Mn, Ni, Co, Al und B im Rohwasser und im Trinkwasser des Zweckverbandes Bodenseewasserversorgung sowie an ausgewählten Tiefenprofilen im Überlinger See werden diskutiert. Die angewandten Untersuchungsmethoden werden eingehend erläutert. Die Ergebnisse zeigen, daß der Gehalt der toxischen Metalle im Bodenseewasser unter 1% der laut Trinkwasserverordnung zulässigen Grenzkonzentrationen liegt. Die höchsten Konzentrationen mit maximal 7% des Grenzwertes wurden beim Element Arsen gefunden — eine für die Bodenseetrinkwasserwerke jedoch immer noch beruhigende Zahl. Dennoch soll speziell diesem Element in weitergehenden Untersuchungen erhöhte Aufmerksamkeit gewidmet werden.
    Notes: Summary A survey is given based on monthly measurements over a one-year period (1977) to determine the trace metals in the raw and drinking water and in two vertical profiles of the Lake of Constance (Überlinger See) by means of atomic absorption spectrometry. The methods used are discussed in detail. The results showed that the content of the toxic metals Hg, Se, Pb, Cr and Cd amounts to less than 1% of the concentration limits due to German law. The highest concentrations were found for the element As, which reached about 7% of the limiting concentration. Further investigations are therefore concerned with this element.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 103-104 
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; Graphitrohröfen, Präzision u. Richtigkeit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 23-27 
    ISSN: 1618-2650
    Keywords: Analyse von Kupfer, Kupfersalzen ; Spektralphotometrie, Atomabsorption ; Ausfällen der Matrix als CuS
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur Bestimmung der Elementspuren Cd, Co, Fe, In, Mn, Ni, Pb, Tl und Zn in reinem Kupfer und Kupfersalzen wird die Matrix als CuS mit Thioacetamid als Fällungsreagens ausgefällt. In 3 N salzsaurer Lösung werden die Elemente mit Ausbeuten ≥ 90 %, Tl zu 75 %, im Filtrat wiedergefunden. Nach Zusatz von HNO3 und Einengen des Filtrats, erhält man ein praktisch rückstandsfreies Spurenkonzentrat, in dem die angereicherten Elemente durch Flammen-Atomabsorptions-Spektrometrie bestimmt werden. Die relative Standardabweichung s/¯x liegt im allgemeinen bei Werten um 0,03. Für Einwaagen von 1 g Kupfer werden Nachweisgrenzen erzielt, die, je nach Element, zwischen 0,2 und 3 ppm liegen.
    Notes: Abstract For the determination of traces of elements such as Cd, Co, Fe, In, Mn, Ni, Pb, Tl and Zn in pure copper and copper salts the matrix is precipitated as CuS using thioacetamide as precipitating reagent. In solutions containing 3 N hydrochloric acid, the recovery of the elements is ≥90 % (Tl 75%). By addition of HNO3 and evaporation of the filtrate to dryness a trace concentrate is received which is practically free of a salt residue and in which the preconcentrated elements are determined by flame AAS. The relative standard deviation s/¯x is generally about 0.03. Using samples of 1 g of copper the limit of detection for different elements was found to be between 0.2 and 3 ppm.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 115-116 
    ISSN: 1618-2650
    Keywords: Best. von Trichloräthylen, Trichloräthanol, Trichloressigsäure in Blut, Harn ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 273 (1975), S. 19-23 
    ISSN: 1618-2650
    Keywords: Analyse von Organozinnverbindungen, Alkylzinnverbindungen, Organozinnstabilisatoren ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die quantitative Bestimmung von Mono-, Di-, Tri- und Tetraalkylzinnverbindungen in Mischungen durch Gas-Chromatographie ist möglich nach Alkylierung zu gemischten Tetraalkylzinnderivaten. Die Alkylierung mit Methyl-, Butyl- und Octylmagnesylchlorid in Diäthyläther ist quantitativ und verläuft ohne Veränderung der ursprünglichen Zinnverteilung. Sie läßt sich nicht nur auf Alkylzinnoxide und -chloride, sondern auch direkt auf Alkylzinn-thioglykolate anwenden. Die aus der Umsetzung der Thioglykolsäureester resultierenden Nebenprodukte werden von der gas-chromatographischen Analyse an Kieselgel absorbiert und die Tetraalkylzinnverbindungen mit n-Pentan eluiert. Die gas-chromatographische Trennung wird wahlweise an Carbowax oder Polyglycol 20000 durchgeführt bei Temperaturen zwischen 100 und 230° C. Die Peak-Flächen entsprechen den Gew.-% Tetraalkylzinn.
    Notes: Abstract The quantitative determination of mono-, di-, tri- and tetraalkyl tin compounds in mixture by GLC is possible after alkylation to mixed tetraalkyl tins. The alkylation with methyl-, butyl- and octyl magnesium chloride runs quantitatively without any change in the original alkyl groups attached to the tin. The method can be applied not only for alkyl tin oxides and chlorides but also directly for alkyl tin thioglycolates. The by-products resulting from the thioglycolic acid ester cleavage are absorbed on silica gel prior to GLC and the tetraalkyl tins are eluted with n-pentane. Gas-chromatographic analysis is carried out alternatively with carbowax and polyglycol 20000 at temperatures between 100 and 230° C. The peak areas correspond to the weight percentage of tetraalkyl tin.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 273 (1975), S. 113-116 
    ISSN: 1618-2650
    Keywords: Best. von Monobutylphosphat, Dibutylphosphat in Tributylphosphat, n-Alkanen ; Chromatographie, Gas ; Überwachung der Wiederaufarbeitung von HTR-Brennelementen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Bei der Wiederaufarbeitung von HTR-Brennelementen durch Solventextraktion nach dem THOREX-Prozeß wird das als Extraktionsmittel verwendete Tributylphosphat/n-Alkan-Gemisch einer intensiven hydrolytischen und radiolytischen Beanspruchung ausgesetzt. Hauptprodukte sind Di- und Monobutylphosphat, die schon in geringen Konzentrationen durch Bildung nicht rückextrahierbarer Urankomplexe und Überführung gewisser Spaltprodukte in die wäßrige Produktphase zu Störungen bei der Extraktion führen. Beide Ester werden durch Sodawäsche aus dem bestrahlten Extraktionsmittel entfernt, welches danach wiederverwendet werden kann. Zur Kontrolle der Wirksamkeit dieser Solventwäsche, der Zusammensetzung des frischen und der Gesamtqualität des recyclierten Extraktionsmittels soll die Gas-Chromatographie innerhalb des JUPITER-Prozesses eingesetzt werden. Sie erlaubt eine quantitative Bestimmung von DBP und MBP bis zu Gehalten von etwa 25 ppm. Die Analysendauer beträgt ca. 100 min.
    Notes: Abstract During reprocessing of HTR fuel elements by the THOREX solvent extraction process the tributylphosphate/n-alcane mixture used as extractant is subject to an intensive radiolytic and hydrolytic burden. Main degradation products are di- and monobutylphosphate which in quite low concentrations disturb the solvent extraction by retention of uranium and transfer of some fission products into the aqueous product solution. Both esters are removed from the irradiated solvent by washing with a sodium carbonate solution, after which the solvent may be recycled. For a control of the efficiency of this solvent recovery procedure as well as of the composition of the fresh and recycled solvent in the JUPITER reprocessing facility, gas chromatography will be used. This method allows the determination of di- and monobutylphosphate down to concentration levels of about 25 parts per million. An analysis requires about 100 min.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 273 (1975), S. 193-195 
    ISSN: 1618-2650
    Keywords: Best. von Barium in Mineralwasser ; Spektralphotometrie, Atomabsorption ; Zweistufentrennung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A method for the determination of barium in strongly mineralised waters was developed. Two-step separation of barium is used for its final determination by atomic absorption spectrometry. Coprecipitation with lead chromate separates barium from the bulk of accompanying elements; final isolation and concentration to a small volume of solution is achieved by subsequent cation-exchange chromatography. Thus, barium can be determined by conventional AAS technique using air-acetylene flame down to 5 μg per liter. The method permits barium determination in water samples containing up to e. g. 40 g of Na+, 40 g of K+, 10 g of Ca2+, 20 g of SO4 2− per liter.
    Notes: Zusammenfassung Eine zweistufige Abtrennung des Bariums wird vor der eigentlichen Bestimmung durchgeführt. Die Hauptmenge an Begleitionen wird durch Mitfällung an Bleichromat entfernt, die endgültige Isolierung und Konzentrierung in einem kleinen Volumen erfolgt durch nachfolgenden Kationenaustausch. So kann Barium mit Hilfe der üblichen AAS-Technik unter Verwendung einer Luft-Acetylen-Flamme bis herab zu 5 μg/l bestimmt werden. Neben Barium können bis 40 g Na+, 40 g K+, 10 g Ca2+ sowie 20 g SO4 2−/l vorhanden sein.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 273 (1975), S. 197-201 
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber in Wasser ; Gesteinen, Kohle, Erdöl ; Spektralphotometrie, Atomabsorption ; flammenlos
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A method for the quantitative determination of Hg in water, rocks, coal and petroleum is described. The Hg is separated from the sample by volatilization and formation of Au amalgam, redissolved and concentrated by electrolysis on gold cathodes. The gold cathodes are heated in the graphite atomizer such that the Hg is volatilized but the cathodes are preserved. The sensitivity of the method is high (0.05 ng/1 % absorption). A certain disadvantage is the long time required for the electrolysis. This, however, can be compensated, first, by the short time (a few minutes) required for the AAS measurement and second, by a rational working rhythm.
    Notes: Zusammenfassung Das Hg wird verdampfungsanalytisch abgetrennt, gelöst und elektrolytisch an Goldkathoden angereichert. Die Goldkathoden werden in der Graphitrohrküvette so aufgeheizt, daß das Hg abdampft, die Goldkathoden jedoch für weitere Messungen erhalten bleiben. Das Verfahren ist mit 0.05 ng/1 % Absorption sehr nachweisempfindlich. Während die Hg-Messung nur wenige Minuten dauert, muß mit Elektrolysezeiten von mindestens 10 h gerechnet werden. Bei hinreichend vielen Elektrolyseeinheiten und einem sinnvollen Arbeitsrhythmus fällt dieser Nachteil nicht so stark ins Gewicht.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 273 (1975), S. 283-286 
    ISSN: 1618-2650
    Keywords: Best. von Kupfer, Silber, Palladium in Verzinnungsbädern, Zinn-Blei-Legierungen ; Spektralphotometrie, Atomabsorption ; Schnellmethode
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eine Absorptionsmethode zur direkten Bestimmung von Cu, Ag und Pd in Pb-Sn-Legierungen wurde erarbeitet. Für die Bestimmung vorteilhafte Absorptionslinien (Cu 324,7 nm, Ag 338,3 nm und Pd 276,3 nm) wurden ermittelt und auf diesen intermetallische Interferenzen von 0–500 ppm Cu, Ag und Pd sowie von 10000ppm Pb und Sn gemessen. 1g der Legierung wird in 10 ml HNO3 (D 1,52) und 2 ml 50 % HF gelöst. Die Lösung wird in einer Acetylen-Luft-Flamme analysiert. Die Methode erlaubt Gehalte bis zu 3·10−4 % Cu, 5·10−4 % Ag und 8·10−4% Pd (zweifache Blindwerthöhe) mit ausreichender Genauigkeit zu bestimmen.
    Notes: Abstract An atomic absorption method for direct determination of Cu, Ag and Pd in Pb-Sn-alloys has been developed. For the determination favourable absorption lines (Cu 324.7 nm, Ag 338.3 nm and Pd 276.3 nm) were found out. Intermetallic interferences of 0–500 ppm of Cu, Ag and Pd as also 10000 ppm of Pb and Sn were measured on these lines. 1 g of the alloy is dissolved in 10 ml HNO3 (d 1.52) and 2 ml of 50 % HF. The solution is analyzed in an acetylene-air flame. This method allows the analyzing of contents up to 3×10−4 % Cu, 5·10−4% Ag and 8×10−4% Pd (twofold blank) with sufficient precision.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 274 (1975), S. 205-206 
    ISSN: 1618-2650
    Keywords: Analyse von Gallium ; Spektralphotometrie, Atomabsorption ; Spurenanreicherung, Injektionsmethode
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 274 (1975), S. 353-357 
    ISSN: 1618-2650
    Keywords: Analyse von Chloriden, Bromiden ; Chromatographie, Gas ; Elemente der III. -V. Gruppe
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The theory for the relation between retention volume and boiling point in gas chromatography was applied to the retention volumes for bromides of IV- and chlorides and bromides of III- and V-group elements in the periodic table, as an extension of the previous paper on chlorides of IV-group elements. The apparent solubility parameter of solventβδ S was separated into the non-regularity parameterβ and the solubility parameter of solventδ S, and the meaning ofβ and the value ofδ S were estimated empirically. Followingδ S values were obtained: Silicon oil DC 550 (8.1), Apiezon grease L (9.1), PEG 1500 (11.6), FeCl3 · 6 H2O (12.5), Low melting point alloy (12.5) and Ga metal (13.4).
    Notes: Zusammenfassung Die Theorie über die Beziehung zwischen Retentionsvolumen und Siedepunkt in der Gas-Chromatographie wurde auf die Retentionsvolumina der Bromide der IV. sowie der Chloride und Bromide der III. und V. Gruppe angewendet (in Fortführung der früheren Arbeit über die Chloride der IV. Gruppe). Der scheinbare Löslichkeitsparameter des Lösungsmittels (βδ S) wurde aufgetrennt in den Unregelmäßigkeitsparameter (β) und den Löslichkeitsparameter des Lösungsmittels (δ S). Die Bedeutung vonβ und der Wert vonδ S wurden empirisch bestimmt. Die folgendenδ S-Werte wurden erhalten: Siliconöl DC 550 (8,1), Apiezonfett L (9,1), PEG 1500 (11,6), FeCl3 · 6 H2O (12,5), niedrigschmelzende Legierung (12,5), Ga-Metall (13,4).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 275 (1975), S. 27-27 
    ISSN: 1618-2650
    Keywords: Best. von Acetylen, Methylacetylen, Äthylacetylen, Vinylacetylen ; Chromatographie, Gas ; Isolierung als Acetylide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 195-198 
    ISSN: 1618-2650
    Keywords: Best. von Chlor, Brom, Jod, Halogenen ; Chromatographie, Gas ; verbesserte Theorie zum Retentionsvolumen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The semi-empirical theory on the retention volume in gas chromatography recently developed by some experiments, was found to require partial correction. It was newly refined and summarized. Overall experimental checking was performed by the use of Cl2, Br2, and I2.
    Notes: Zusammenfassung Die halbempirische Theorie über das Retentionsvolumen in der Gas-Chromatographie, die kürzlich an Hand einiger Versuche entwickelt wurde, erforderte eine teilweise Korrektur. Sie wurde verbessert und zusammenfassend dargestellt. Kontrollversuche wurden mit Hilfe von Chlor, Brom und Jod durchgeführt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 199-202 
    ISSN: 1618-2650
    Keywords: Analyse von Schwefelorganoverbindungen ; Chromatographie, Gas ; FID-Empfindlichkeitsfaktoren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The molar responses and specific weight correction factors for 25 aliphatic sulphur compounds in the 10 μg range were measured with a hydrogen flame-ionisation detector. No abnormal behaviour was found with sufficiently high ratio air/H2. The molar response of the sulphides and disulphides is strictly proportional to the carbon number. For a certain organic residue the weight correction factor is proportional to the number of sulphur atoms (or the molecular weight). No destructive effects on the detector burner and no decrease of sensitivity were observed.
    Notes: Zusammenfassung Die molaren Empfindlichkeiten und stoffspezifischen Gewichtskorrekturfaktoren für 25 aliphatische Schwefelverbindungen im 10 μg-Bereich wurden mit einem Wasserstoff-Flammionisationsdetektor gemesssen. Bei genügend hohem Strömungsverhältnis (Luft/Wasserstoff) wird kein ungewöhnliches Verhalten gefunden. Die molare Empfindlichkeit der Sulfide und Disulfide ist streng proportional der Kohlenstoffzahl. Für einen bestimmten organischen Rest ist der Gewichtskorrekturfaktor proportional der Zahl der S-Atome (oder dem Molgewicht). Destruktive Einflüsse auf den Brenner des Detektors und Abnahme der Empfindlichkeit wurden nicht beobachtet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 288-288 
    ISSN: 1618-2650
    Keywords: Best. von Arsen in Wasser ; Spektralphotometrie, Atomabsorption ; flammenlos, Müllsickerwasser
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 337-345 
    ISSN: 1618-2650
    Keywords: Best. von Cadmium in Bleidioxid, Vanadiumpentoxid, Uranoctoxid ; Spektralphotometrie, Atomabsorption ; Laserverdampfung, Rasteranalyse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eine flammenlose Methode für die AAS wird beschrieben, die zur Mikro- und Lokalanalyse von Festkörpern eingesetzt werden kann. Die Verdampfung ausgewählter Probenbereiche erfolgt mit einem Ionen-Dauerstrichlaser. Die Cadmiumgehalte in V2O5-, PbO2- und U3O8-Proben, die unterschiedliche Cadmiumkonzentrationen enthalten, werden bestimmt. Die verdampfte Substanzmenge pro Messung beträgt ca. 1 μg, die aus einer Probenfläche von ca. 0,008 mm2 erhalten wird. Die Empfindlichkeit für die Cadmiumbestimmung beträgt 2,1 · 109 g Cd/1% Absorption und die Nachweisgrenze 4,8 · 10−10 g Cd. Als ein Anwendungsbeispiel folgt die Beschreibung und Auswertung einer Mikrorasteranalyse: von einer 14 mm2 Probenfläche wird aus 57 Einzelmeßwerten ein Konzentrationsprofil des Dotierungselementes ermittelt. Dafür werden zwei graphische Darstellungen vorgeschlagen. Vorteile des Verfahrens werden durch Vergleich mit bisher bekannten Techniken erläutert.
    Notes: Abstract A flameless method for AAS is described, which can be used for micro- and local analysis of solid samples. The evaporation of chosen areas of the sample is achieved with a continuous wave ion laser. The evaporated mass of each measurement is about 1 μg, which comes from an area of 0.008 mm2 from the surface of the specimen. The cadmium contents of samples of vanadium, lead and uranium oxides containing different concentrations of cadmium were determined. The sensitivity of the cadmium analysis is 2.1 · 10−9 g of Cd/1% absorption and the detection limit is found to be 4.8 · 10−10 g of cadmium. The description and interpretation of a raster microanalysis as an application of this method follows: 57 point measurements from an area of 14 mm2 are used to construct concentration contours of the doping element. Two graphic representations are suggested. The advantages of this method are compared with other known techniques.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 347-349 
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; ohne Wägung, auf See
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Um das auf See problematische Einwiegen von Erzproben zur Analyse durch Atomabsorptions-Spektrometrie zu umgehen, wird eine indirekte Ermittlung der eingesetzten Probemenge durch die Bestimmung eines „Leitelementes“ mittels Isotopfluorescenzanalyse erprobt. Am Beispiel von Manganknollen des Pazifischen Ozeans, die 15–30% Mn, 0,5–1,5% Ni und Cu enthalten, wird gezeigt, daß sich die beiden zuletzt genannten Elemente auf diese Weise mit einer Genauigkeit von besser als 10% rel. bestimmen lassen.
    Notes: Abstract The weighing of ore samples to be analyzed by atomic absorption spectrometry is somewhat problematical at sea. To evade the weighing, tests have been made to try out an indirect determination of the mass of the sample by determining a “reference element” by means of isotope fluorescence analysis. The analysis of manganese nodules from the Pacific Ocean, containing 15–30% of Mn and 0.5–1.5% of Ni and Cu, is quoted as an illustration. It has been shown that the two latter elements can be determined in this way with an accuracy of at least 10% rel.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 278 (1976), S. 97-103 
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; vereinfachte Additionsmethode, Korrekturprogramm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein vereinfachtes Verfahren der Additionsmethode in der Atomabsorptionsspektrometrie wird beschrieben. Bei diesem vereinfachten Verfahren werden die Bestimmungen sämtlicher Elemente in einer einzigen Probe durchgeführt. Die Auswertung und die dazu notwendigen Korrekturen werden mit Hilfe eines Computerprogramms vorgenommen. Das beschriebene Verfahren liefert gute Ergebnisse bei geringem Arbeitsaufwand.
    Notes: Abstract With this simplified method all determinations of all the elements are carried out in only one probe. The errors are corrected by a computer program. With the method described good results can be obtained with little expenditure of work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 278 (1976), S. 115-120 
    ISSN: 1618-2650
    Keywords: Verwendung von Glykolmethacrylat zur Spurenanalyse ; Gele mit Hydroxychinolin ; Best. von Kupfer, Eisen, Mangan, Blei in Ammoniumfluorid ; Spektralphotometrie, Atomabsorption ; flammenlos, Glykolmethacrylatgel
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Hydrophile makroporöse Copolymere von Glykolmethacrylat mit Glykolmonomethacrylat mit über eine Azogruppe gebundenem 8-Hydroxychinolin zeichnen sich durch eine rasche Gleichgewichtseinstellung bei Austauschprozessen aus (2–5 min). Die Sorptionsisothermen von Pb2+ und Cu2+ wurden gemessen (Sorptionsvermögen 0,2–0,3 mMol Me/g). Die Verteilungskoeffizienten für Pb2+ und Cu2+ sinken von etwa l05 auf 102 bei 90% iger Sättigung. Die Anwendung von Mikrokolonnen (0,02 ml Gesamtvolumen des Austauschers) zur Abtrennung und Anreicherung von Schwermetallspuren in ng-Mengen für die nachfolgende flammenlose Atomabsorption wurde vorgeschlagen. Als Beispiel wird die Bestimmung von Cu, Fe, Mn und Pb (5×10−7–5×10−5%) in Ammoniumfluorid beschrieben.
    Notes: Abstract Hydrophilic macroporous glycolmethacrylate-glycolmonomethacrylate copolymers with 8-hydroxyquinoline, bound via the azo-group, possess a high equilibration rate for exchange processes (2–5 min). The sorption isotherms of Pb2+ and Cu2+ have been studied (sorption capacity of 0.2–0.3 mMol · g−1. The partition coefficients for Pb2+ and Cu2+ (about 105 for unsaturated exchanger) are lowered in dependence of the exchanger saturation (about 102 for 90% saturation). The use of microcolumns (total volume of the exchanger 0.02 ml) for the separation and enrichment of traces of heavy metals in ng-amounts for the subsequent flameless atomic absorption spectroscopy is proposed. The determination of Cu, Fe, Mn and Pb (5×10−7 to 5x10−5%) in a high purity ammonium fluoride is described as an example.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    ISSN: 1618-2650
    Keywords: Best. von Trimethylsilyl-Gruppen in N-silylierten Verbindungen, Carbonsäuretrimethylsilylestern ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A method has been developed for the determination of trimethylsilyl groups in N-silylated compounds and in trimethylsilyl esters of carboxylic acids. The method is based on the desilylation of the compound to be analysed with phenol followed by gas-chromatographic determination of the trimethylphenoxysilane formed. The relative error of the determination is around 1% and the standard deviation is 1.20 × 10−3 (3.12%). A single determination takes less than 2 h.
    Notes: Zusammenfassung Das Verfahren beruht auf der Desilylierung der zu analysierenden Verbindung mit Phenol und der anschlie\enden gas-chromatographischen Bestimmung des gebildeten Trimethylphenoxysilans. Der relative Fehler der Bestimmung beträgt ca. 1% und die Standardabweichung 1,20 × 10−3 (3,12%). Die Bestimmungszeit ist kürzer als 2 h.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 281 (1976), S. 103-107 
    ISSN: 1618-2650
    Keywords: Best. von Platin ; Spektralphotometrie, Atomabsorption ; Einfluß von Pd, Rh
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die AAS-Bestimmung von Platin wird von zahlreichen Elementen zum Teil sehr stark gestört. Durch Zusatz von Uran kann der Einfluß von Palladium und Rhodium mit Hilfe quadratischer Korrekturgleichungen beseitigt werden. Lanthan ist als Puffer ungeeignet.
    Notes: Abstract There are a number of serious interferences in the determination of platinum by atomicabsorption spectrometry. The influences of palladium and rhodium have been investigated. It is shown that they can be eliminated by an addition of uranium and by quadratic correction equations. Addition of lanthanum is not suitable.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 281 (1976), S. 131-133 
    ISSN: 1618-2650
    Keywords: Best. von Molekulargewicht, Löslichkeitsparameter von Hochpolymeren ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A new method for the simultaneous determination of molecular weight and solubility parameter of high-polymer was proposed using the sample polymer as the solvent and a halogen as the solute in gas chromatography at two different temperatures. Molecular weights of Silicon Oil DC 550, 702, and 710, and of PEG 1500, 4000, and 6000 are 50000, 62300, and 89200, and 1500, 3100, and 6750, respectively. Solubility parameters of them are 8.1, 8.0, and 7.9, and 11.7, 11.6, and 11.6, respectively.
    Notes: Zusammenfassung Bei der empfohlenen Methode wird eine gas-chromatographische Bestimmung bei zwei verschiedenen Temperaturen mit dem Polymeren als Lösungsmittel und einem Halogen als gelöster Substanz durchgeführt. Die Molekulargewichte von Silicon Oil DC 550, 702 und 710 sowie von PEG 1500, 4000 und 6000 wurden zu 50000, 62300, 89200, 1500, 3100 und 6750 gefunden; die entsprechenden Löslichkeitsparameter betragen 8,1, 8,0, 7,9, 11,7, 11,6 und 11,6.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 281 (1976), S. 299-299 
    ISSN: 1618-2650
    Keywords: Best. von Silber in Kupfer ; Spektralphotometrie, Atomabsorption ; Extraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 281 (1976), S. 291-294 
    ISSN: 1618-2650
    Keywords: Best. von Rhodium ; Spektralphotometrie, Atomabsorption ; Einfluß von Pt und Pd
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Beeinflussung der atomabsorptionsspektroskopischen Rhodiumbestimmung ist gering. Verglichen mit den Elementen Pt und Pd sind die Meßwerte bei Abwesenheit von Fremdionen am genauesten. Der Zusatz von Uran oder Lanthan als spektroskopische Puffer erhöht die Empfindlichkeit. Der von Palladium und Platin verursachte Störeinfluß kann nicht mit quadratischen Korrekturgleichungen eliminiert werden. Zur Unterdrückung des Einflusses eignet sich Uran als Puffersubstanz am besten. Mit dem Pufferzusatz kann der verbleibende Einfluß mit Korrekturgleichungen korrigiert werden.
    Notes: Summary The influence on the determination of rhodium is only slight. In comparison with the elements Pt and Pd the measurements are most exact in the absence of foreign ions. Addition of uranium or lanthanum as spectroscopic buffers causes an increase in sensitivity. The interfering effects of palladium and platinum cannot be eliminated by correcting equations. However, with the addition of uranium as a buffer the effects are minimized and the remaining influence can be corrected by means of equations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 281 (1976), S. 300-300 
    ISSN: 1618-2650
    Keywords: Best. von Zink, Cadmium, Wismut in Kupfer ; Spektralphotometrie, Atomabsorption ; Extraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    ISSN: 1618-2650
    Keywords: Best. von Arsen, Antimon, Selen ; Spektralphotometrie, Atomabsorption ; Vergleich d. Reduktion mit Zn/SnCl2/KJ oder NaBH4
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An atomic-absorption spectrophotometric method for the rapid and sensitive determination of arsenic, antimony, and selenium with the hydride-argon/hydrogen flame system has been studied. The comparison of the zinc tablet combined with stannous chloride and potassium iodide, and the sodium borohydride tablet reduction systems are described. The sensitivities and precisions of both reduction systems are estimated to be nearly the same. From the results of the comprehensive study on interferences, the zinc system is concluded to be more selective than the sodium borohydride system, which is especially true for arsenic.
    Notes: Zusammenfassung Ein atomabsorptionsspektralphotometrisches Verfahren zur raschen und empfindlichen Bestimmung von Arsen, Antimon und Selen über ihre Hydride unter Verwendung der Argon-Wasserstoff-Flamme wurde im Hinblick auf die Reduktionssysteme untersucht. Die Verwendung von Zinktabletten in Kombination mit Zinn(II)-chlorid und Kaliumjodid sowie von Natriumborhydridtabletten wurde geprüft und gefunden, daß in bezug auf Empfindlichkeit und Reproduzierbarkeit keine nennenswerten Unterschiede bestehen. Das Zinksystem bietet jedoch eine bessere Selektivität, besonders im Falle von Arsen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 282 (1976), S. 21-23 
    ISSN: 1618-2650
    Keywords: Analyse von Cadmium ; Spektralphotometrie, Atomabsorption ; Anreicherung der Spuren durch partielles Lösen der Matrix
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Aus Reinst-Cadmium können durch partielles Lösen der Matrix die Elementspuren Ag, Au, Bi, Co, Cu, Fe, In, Ni, Pb, Pd und Sn angereichert werden. Dazu werden die Proben mit einem dünnen Quecksilberfilm überzogen und in Bromwasserstoffsäure bis auf einen kleinen Rest gelöst. Die im Löserückstand angereicherten Spuren werden durch Atomabsorptions-Spektrometrie bestimmt. Die relativen Standardabweichungen betragen etwa 0,05; die Anreicherungsausbeuten sind 〉 95%. Bei Einwaagen von 10 g Cadmium beträgt der Anreicherungsfaktor etwa 102; die Nachweisgrenzen (3σ-Grenzen) liegen um 0,1 ppm. Der Einfluß der Lösebedingungen auf die Anreicherung wird diskutiert.
    Notes: Abstract Trace elements such as Ag, Au, Bi, Co, Cu, Fe, In, Ni, Pb, Pd, and Sn can be preconcentrated from high-purity cadmium by partial dissolution of the matrix. The samples are coated by a thin film of mercury and dissolved in hydrobromic acid up to a small residue. In this residue the trace elements are enriched with recoveries of more than 95%. The elements are determined by AAS. For 10 g Cd the factor of enrichment is about 102, and the limits of detection are in the range of 0.1 ppm. The relative standard deviation was calculated to be about 5%. Reasons influencing the recovery of the trace elements are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 282 (1976), S. 119-121 
    ISSN: 1618-2650
    Keywords: Best. von Chrom ; Spektralphotometrie, Atomabsorption ; Einfluß der Wertigkeit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Intensität des flammenabsorptionsspektrometrischen Cr-Signals hängt in einer sehr komplexen Weise von der Wertigkeit des Chroms und der Flammentemperatur ab. Ferner ist ein ausgeprägter Kalium-Einfluß vorhanden. Alle diese Schwierigkeiten können am besten dadurch eliminiert werden, daß in der Lachgasflamme gearbeitet und die Analysenlösung mit einer höheren K-Konzentration „gepuffert“ wird.
    Notes: Abstract The intensity of the chromium signal in AAS depends in a very complex manner strongly on the valency of the Cr and the flame temperature. It is furthermore influenced by potassium, if present. The best way to overcome all these interferences is to use the nitrous oxide flame and to “buffer” the solution with a higher concentration of potassium.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    ISSN: 1618-2650
    Keywords: Best. von Arsen als Hydrid ; Spektralphotometrie, Atomabsorption ; Maskierung von Störungen mit KJ
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; Methanpyrolyse zur Behandlung des Graphitrohr-Atomisators
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 9-14 
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary In the first part different methods for studying interferences of the time dependent signal in flameless AAS are presented with emphasis on factorial designs in experimentation as opposed to the one-factor-at-a-time approach. An example of the statistical computations necessary for interpretation of a multifactor experiment is worked out and discussed in detail with special consideration of the explanation of first-order interactions. The influence of instrumentation upon determinations in the graphite furnace is dealt with in the second part: The temperature in the graphite furnace was measured with a pyrometer, a thermocouple and a Hg-thermometer. The results obtained with the pyrometer were in good agreement with the values given by the manufacturer. The stability of the AAS system was checked and found to be sufficient for the investigation of interferences.
    Notes: Zusammenfassung Im ersten Abschnitt werden die verschiedenen Möglichkeiten zur Untersuchung von Störungen des zeitabhängigen Signals bei der flammenlosen AAS aufgezeigt, wobei besondere Bedeutung den faktoriellen Versuchsplänen im Gegensatz zu einparametrigen Untersuchungen beigemessen wird. Ein Beispiel der statistischen Auswertung zur Interpretation eines Experiments mit mehreren Faktoren wird gebracht, und dabei besonderes Gewicht auf die Erklärung von Wechselwirkungen zwischen zwei Faktoren gelegt. Im zweiten Abschnitt werden die apparativen Einflüsse auf Messungen in der Graphitrohrküvette behandelt. Dazu wurde die Temperatur im Graphitrohr mit einem Pyrometer, einem Thermoelement und einem Quecksilberthermometer gemessen. Die Temperaturen, die mit der pyrometrischen Methode gefunden wurden, stimmen gut mit den vom Hersteller angegebenen Werten überein. Die Stabilität des AAS-Gerätes wurde überprüft: sie reicht für die Durchführung von Interferenzstudien aus.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 97-103 
    ISSN: 1618-2650
    Keywords: Best. von Cadmium ; Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Interferences in the flameless determination of cadmium using the HGA 72 were studied for HCl, HNO3, H2SO4, HClO4 and HF and found to be depending on different thermal pretreatment. The interferences of cations were much smaller than for anions. The results are discussed with respect to thermal stability as well as atomization rate of the compositions under investigation. Special emphasis is put upon the presence of interactions between interferents, which in some cases can be used to eliminate interferences.
    Notes: Zusammenfassung Interferenzen, die bei der flammenlosen Bestimmung von Cadmium in der HGA 72 auftreten, wurden bei HCl, HNO3, H2SO4, H3PO4, HClO4 und HF studiert; die AbhÄngigkeit ihres Auftretens von der thermischen Vorbehandlung wird gezeigt. Interferenzen von Kationen sind kleiner. Die Ergebnisse werden im Hinblick auf die thermische StabilitÄt und die Atomisierungsgeschwindigkeit der Proben diskutiert. Besonders betont wird die Gegenwart von Wechselwirkungen zwischen Störungen, die manchmal auch benützt werden können, um Interferenzen auszuschalten.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 183-190 
    ISSN: 1618-2650
    Keywords: Best. von Blei ; Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Interferences in the flameless determination of lead using the HGA 72 were studied for HCl, HNO3, H2SO4, H3PO4, HClO4, HF and for a number of cations. In certain instances interferents in just 1000-fold concentration over lead are shown to cause deviations in the lead signal. Many of the interferences are matrix-dependent themselves and can be reduced by matrix variations. Optimization of the thermal pretreatment can be used effectively to reduce random error and/or systematic errors. The thermal stability of lead compounds in the graphite furnace was sufficient for charring procedures up to 900° C for 20 s.
    Notes: Zusammenfassung Interferenzen, die bei der flammenlosen Bestimmung von Blei in der HGA 72 auftreten, wurden bei HCl, HNO3, H2SO4, H3PO4, HClO4, HF und einigen Kationen studiert. In gewissen Fällen reicht ein nur 1000 facher Überschuß des Störions, um Abweichungen vom Signal des Bleistandards hervorzurufen. Da das Auftreten von Interferenzen auch oft matrixabhängig ist, können Matrixvariationen zur Unterdrückung von Interferenzen eingesetzt werden. Die Optimierung des Temperaturprogrammes wird erfolgreich zur Beeinflussung des Zufallsfehlers und/ oder systematischer Fehler herangezogen. In der Graphitrohrküvette reichte die Stabilität der Bleiverbindung aus, um beim Veraschungsschritt die Temperatur bis auf 900° C (20 s) zu steigern.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 337-341 
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber in Luft, Gasen ; Spektralphotometrie, Atomabsorption ; flammenlos
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Mercury is adsorbed on cellulose powder and activated charcoal. The contents of the adsorber are burnt in the oxy-hydrogen flame, and the mercury determined by the flameless atomic absorption procedure. The method is applicable to mercury present as metallic vapour, organo mercurical compounds and particulate matter containing adsorbed mercury compounds. The combustion step eliminates all possible non-atomic absorption interferences in the measuring procedure and ensures quantitative recovery of the mercury from the adsorption material. Quantitative adsorption recovery over a wide range of flow rate from 2–200 l/h allows the use of small battery operated pumps for personal monitoring, or vacuum pumps for high speed and large volume sampling. The range of flow rate makes isokinetic sampling conditions possible.
    Notes: Zusammenfassung Quecksilber wird an Cellulosepulver und Aktivkohle adsorbiert. Der Inhalt des Adsorbers wird in der Wasserstoff-Sauerstoff-Flamme verbrannt und das Quecksilber durch flammenlose Atomabsorption bestimmt. Die Methode erfa\t Quecksilber als Metalldampf, in Form von Organo-Quecksilberverbindungen sowie Quecksilberverbindungen, die an Staubpartikel adsorbiert sind. Die Verbrennung in der Wasserstoff-Sauerstoff-Flamme eliminiert Störungen durch nicht-atomare Absorption bei der AAS-Messung und garantiert die quantitative Erfassung des adsorbierten Quecksilbers. Die quantitative Adsorption über einen gro\en Bereich der Durchflu\geschwindigkeit von 2–200 l/h erlaubt batteriebetriebene Pumpen für die Quecksilbermessung „am Mann“, oder den Einsatz von Vakuumpumpen für die Probenahme bei hoher Durchflu\rate und gro\em Probenvolumen. Der gro\e Bereich der Durchflu\rate gestattet isokinetische Bedingungen für die Probenahme.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 285 (1977), S. 45-46 
    ISSN: 1618-2650
    Keywords: Analyse von Schwefelverbindungen, aliphat ; Chromatographie, Gas ; Zusammenstellung von Retentionsindices
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 285 (1977), S. 107-109 
    ISSN: 1618-2650
    Keywords: Trenn. von Kationen als Diäthyldithiophosphinatochelate ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Das thermogravimetrische und gas-chromatographische Verhalten einiger Bis-(diäthyldithiophosphinato) chelate wird beschrieben. Beispiele für Trennungen und Bestimmungen anorganischer Kationen (Zn, Cd, Co, Ni, Pb) werden gegeben.
    Notes: Abstract The thermogravimetric and gas-chromatographic behaviour of some bis-(diethyldithiophosphinato) chelates is described. Examples for the separation and determination of several inorganic cations (Zn, Cd, Co, Ni, Pb) are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 20-26 
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber in Biolog. Material, Umweltmaterial ; Spektralphotometrie, Atomabsorption ; AutoAnalyzer, Anreicherung an Silberwolle, ng-Bereich.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein modifiziertes automatisiertes Kaltdampf-AAS-Verfahren mit einem AutoAnalyzer II®-System wird beschrieben. Das Verfahren erlaubt sowohl die Bestimmung von anorganischem wie die von Gesamtquecksilber und erlaubt bis zu 120 Analysen/Tag. Die Anreicherung von Quecksilber als Amalgam an Silberwolle, gefolgt von rascher thermischer Zersetzung mit Hilfe einer Graphitküvette ermöglicht eine Nachweisgrenze von 0.01 ng/ml Probenlösung. Die relative Standardabweichung für homogenes Probenmaterial und das Gesamtverfahren ist ≤15%. Während der Analyse von Standard-Referenz-Proben wurden keine systematischen Abweichungen beobachtet. Der mittlere Gesamt-(2σ)fehler für eine einzelne Probe sollte daher 30% nicht überschreiten.
    Notes: Summary A modified automated cold vapour AAS procedure using an AutoAnalyzerII® system is described. The procedure permits the determination of inorganic as well as total mercury and enables to perform up to 120 analyses/day. The enrichment of mercury as amalgam on silver wool, followed by a fast thermal decomposition with the aid of a graphite cuvette enables a detection limit of 0.01 ng/ml sample solution. The relative standard deviation for homogeneous samples and the overall procedure is ≤15%. During the analysis of certified standard reference materials no systematic deviations were observed. The average total (2σ) error for a single sample should therefore not exceed 30%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 127-127 
    ISSN: 1618-2650
    Keywords: Best. von Beryllium in Luft ; Spektralphotometrie, Atomabsorption ; flammenlos
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 299 (1979), S. 261-263 
    ISSN: 1618-2650
    Keywords: Best. von Kupfer in Zirkoniumsalzen ; Spektralphotometrie, Atomabsorption ; HF-Zusatz
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An AAS method is described for the direct determination of traces of copper in zirconium(IV) oxide chloride and nitrate. An interference study of the zirconium matrix is reported. Best conditions for the removal of the suppressive effect of zirconium on the copper signal by addition of hydrofluoric acid are described. Results obtained by analyzing commercial samples from different manufacturers are presented.
    Notes: Zusammenfassung Kupferverunreinigungen wurden in Zirkoniumoxidchlorid und -nitrat bestimmt. Störungen durch die Matrix wurden untersucht. Die abschwächende Wirkung des Zr auf das Cu-Signal wurde durch Zusatz von Fluorwasserstoffsäure beseitigt. Analysenergebnisse für verschiedene handelsübliche Zr-Salze werden mitgeteilt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 199-202 
    ISSN: 1618-2650
    Keywords: Verhalten von Di(trifluoroäthyl)dithiocarbamatochelaten ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Das gas-chromatographische Verhalten einiger Di(trifluoäthyl)dithiocarbamatochelate unter isothermen und temperaturprogrammierten Arbeitsbedingungen verschiedener Säulen wird beschrieben. Multielementanalyse von bis zu wenigstens neun Elementen dürfte auch nach Ausschütteln aus wäßrigen Lösungen möglich sein.
    Notes: Summary Gas chromatographic behaviour of some di(trifluoroethyl)dithiocarbamatochelates is investigated under isothermal and temperature programmed working conditions of various columns. Multielemental analysis of up to at least nine elements seems to be possible even after extraction out of aqueous solutions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 216-218 
    ISSN: 1618-2650
    Keywords: Best. von Pharmazeut. Produkten im Harn ; Chromatographie, Gas ; Extrelut, saure u. neutrale Stoffe
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zum gas-chromatographischen Nachweis saurer und neutraler Arzneistoffe wurden Harnproben bei pH 6 an Extrelut® (Merck) mit Diäthyläther extrahiert. Die Wiederfindungsraten der meisten untersuchten Arzneistoffe liegen im gleichen Bereich wie bei der üblichen Flüssig-Flüssig-Extraktion im stärker sauren Milieu. Jedoch verbleiben endogene Carbonsäuren, welche die Auswertung der Chromatogramme erschweren, in der wäßrigen Phase.
    Notes: Summary Samples of urine at pH 6 were extracted with diethyl ether from Extrelut® (Merck) columns for the gas-chromatographic identification of acidic and neutral drugs. The recovery rates for most of the investigated substances were similar to those of usual liquid-liquid extraction from strongly acidic media. Endogenous carboxylic acids however, which would otherwise interfere in the chromatogram, remained in the aqueous phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 297 (1979), S. 44-48 
    ISSN: 1618-2650
    Keywords: Best. von Uran ; Spektralphotometrie, Atomabsorption ; Verbesserung durch Interferenzzusätze
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die nachstehend beschriebene Untersuchung zeigt, daß manche Metallionenzusätze Empfindlichkeitsverbesserungen bei der Bestimmung des Urans durch Flammen-AAS ergeben. Als wirksamster Zusatz wurde Gallium gefunden, das die Empfindlichkeit gegenüber reiner Uranlösung etwa um den Faktor 5 steigern kann. Durch die Anwendung der sogenannten Injektionsmethode kann mit kleinsten Probevolumen die zur Analyse notwendige Absolutmenge des Urans bis zur Nachweisgrenze von 0,5 μg vermindert werden. Zusätzlich wurde die bewährte Uran-Extraktions-Aufkonzentrierungsmethode mit Triphenylarsinoxid in CHCl3 für die AAS modifiziert, womit in vielen Fällen eine weitere Erniedrigung der Nachweisgrenze erzielt werden kann.
    Notes: Summary This paper describes some improvements in the sensitivity of the uranium analysis by atomic absorption spectrometry as obtained by addition of certain metallic ions to the solution in question. Thus a factor of about 5 can be achieved by addition of 10 mg of gallium/ml. By applying the injection method very small amounts of uranium down to 0.5 μg can be analyzed. The very efficient purification and concentration of the uranium by extraction with triphenylarsine oxide in chloroform was adapted to this AAS procedure, thus allowing even lower limits of detection.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 297 (1979), S. 381-383 
    ISSN: 1618-2650
    Keywords: Best. von Chrom(III), Chrom(VI) in Was-ser ; Spektralphotometrie, Atomabsorption ; Extraktion mit APDC-MIBK
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary With the well-known APDC-MIBK extraction of dissolved trace metals from aqueous solutions for AAS analysis only Cr6+ is determined, whereas practically no Cr3+ is extracted. This technique was therefore modified (PHP-buffer; pH 4.7–5.5; 80° C; 20 min reaction time) so that hexavalent and trivalent chromium can be extracted simultaneously into the organic phase, thus allowing determination of the percentage of each of these ionic species in water (hexavalent chromium being determined separately). A procedure for the modified extraction is described.
    Notes: Zusammenfassung Mit der bekannten APDC-MIBK-Extraktion gelöster Spurenmetalle aus wäßrigen Lösungen für die AAS-Analyse wird nur Cr6+ erfaßt, während Cr3+ praktisch nicht extrahiert wird. Die bisherige Methode wurde deshalb so modifiziert (PHP-Puffer; pH 4,7–5,5; 80° C; 20 min Reaktionszeit), daß mit dem sechswertigen auch das dreiwertige Chrom in die organische Phase extrahiert wird und so der Anteil beider lonenarten bestimmt werden kann (nach getrennter Bestimmung des Cr6+). Eine Arbeitsvorschrift wird angegeben.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 298 (1979), S. 123-127 
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; flammenlos, Spurenanalyse, direkte Probenzuführung in Graphitofen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die direkte Bestimmung von Spurenelementen in metallischen und oxidischen Proben im Gehaltsbereich 0,1–10 μg/g (entsprechend 10−5-10−3 Massen-%) wird beschrieben. Hierzu bietet sich die Verwendung einer speziellen Graphitofen-Boottechnik an, mit deren Hilfe die Proben direkt in fester Form eingebracht werden können. Zwei unterschiedliche Verfahren sind erforderlich: die mehrfache Aufschmelzung für metallische Proben und die zweifache Verdampfung von oxidischen Stoffen. Die Resultate beider Verfahren werden diskutiert.
    Notes: Summary The direct determination of trace elements of metallic and oxidic samples in the range of 0.1–10 μg/g (or 10−3–10−5 mass-%) is described by using a special graphite furnace boat-technique with direct sample input. Two different procedures are necessary: a multiple heating technique in case of metallic samples and a double vapourization technique in case of oxides. The results using both techniques are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 129-131 
    ISSN: 1618-2650
    Keywords: Identifizierung von Phenyläthylaminderivaten ; Chromatographie, Gas ; Kovats-Indices
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 102-103 
    ISSN: 1618-2650
    Keywords: Best. von Natrium, Kalium ; Spektralphotometrie, Flammenemission ; Best. von Calcium, Magnesium ; Spektralphotometrie, Atomabsorption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 158-159 
    ISSN: 1618-2650
    Keywords: Best. von 3α-Ätiocholanolon in Plasma ; Chromatographie, Gas ; Alkaliflammendetektor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 275 (1975), S. 353-357 
    ISSN: 1618-2650
    Keywords: Best. von Wismut in Stahl ; Spektralphotometrie, Atomabsorption ; flammenlos
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A method for the determination of bismuth in high and low alloy steels has been developed. Samples were dissolved in hydrochloric-nitric acid (2∶1). A graphite furnace of Massmann-type was used for determinations. Ammonia was added to the samples in the tube. Because of this treatment samples could be ashed at higher temperatures and non-specific absorption was thereby minimised. Samples could be determined without background correction. The time for one analysis was 15 min. Interferences from chromium, nickel, iron and molybdenum as well as from the acids used for dissolution of samples were investigated. It was shown that the inert gas flow-rate during ashing affected the sensitivity.
    Notes: Zusammenfassung 0,5 g der Probe wird in einem Salzsäure/Salpetersäure-Gemisch (2∶1) gelöst und auf 50 ml verdünnt. 2 μl dieser Lösung werden in einen Graphitofen nach Massmann überführt und mit 10 μl 0,4 M Ammoniak versetzt. Dadurch konnte die Probe bei höherer Temperatur verascht werden, wodurch die unspezifische Absorption so vermindert wurde, daß ohne Untergrundskorrektur gearbeitet werden konnte. Eine vollständige Analyse dauert 15 min, die Nachweisgrenze beträgt 0,5 μg Bi/g Probe. Störungen sowohl durch Chrom, Nickel, Eisen und Molybdän als auch durch Salzsäure und Salpetersäure wurden untersucht. Die Strömungsgeschwindigkeit des inerten Spülgases beeinflußt die Signalhöhe.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 279 (1976), S. 351-354 
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; Optimierung von Meßbedingungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eingehende Untersuchungen zeigen, daß die Leistungsfähigkeit der Atomabsorptionsspektroskopie gewöhnlich nicht optimal genutzt wird. Der Einfluß wesentlicher Größen, wie Viscosität, Temperatur, Salzkonzentrationen, Oberflächenspannung usw. wird untersucht bzw. anhand der Hagen-Poiseuilleschen Gleichung diskutiert.
    Notes: Abstract Detailed tests have been made to show the efficiency of a modern atomic absorption spectrometer. The influence of different parameters as: viscosity, temperature, concentration of salts, surface tension etc., is discussed on the basis of Hagen-Poiseuille's equation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 276 (1975), S. 127-128 
    ISSN: 1618-2650
    Keywords: Best. von Essigsäure und Propionsäure in Polyamid 6 ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 280 (1976), S. 9-13 
    ISSN: 1618-2650
    Keywords: Best. von 2,3,7,8-Tetrachlordibenzo-p-dioxin in 2,4,5-Trichlorphenoxyessigsäure ; Chromatographie, Gas ; DAPA, Dioxin-Panel
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird eine Methode zur Bestimmung von 2,3,7,8-Tetrachlordibenzo-p-dioxin in 2,4,5-T beschrieben. 2,4,5-T wird in Dimethylformamid-Acetonitril-Wasser gelöst und mit Hexan extrahiert. Der Extrakt wird säulen-chromatographisch an Aluminiumoxid und dünnschicht-chromatographisch an Kieselgel gereinigt. Die quantitative Bestimmung des Dioxins erfolgt gas-chromatographisch auf einer SE 30-Säule mit Hilfe eines FID. Die Wiederauffindungsrate liegt bei etwa 95%, die Nachweisgrenze bei etwa 0,03 ppm. Die vom Dioxin-Panel erarbeitete Methode wurde in zwei Ringversuchen getestet.
    Notes: Abstract 2.4.5-T is dissolved in dimethylformamide-acetonitrile-water, and extracted with hexane. The extract is purified by chromatography in a column of alumina, followed by thin-layer chromatography on silicagel. The quantitative determination of dioxin is achieved by gas-liquid chromatography on a column containing SE 30 with flame-ionization detection. Recovery of dioxin is about 95%, limit of detection about 0.03 ppm. The method of the dioxin panel was tested in two collaborative studies.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 280 (1976), S. 359-364 
    ISSN: 1618-2650
    Keywords: Best. von Palladium neben Platin, Rhodium ; Spektralphotometrie, Atomabsorption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die atomabsorptionsspektroskopische Palladiumbestimmung wird vom Platin nicht und vom Rhodium nur wenig beeinflußt. Berücksichtigt man, daß ein Zusatz von Uran die Palladiumbestimmung neben Rhodium desaktiviert, so liegen allgemein die günstigsten Bedingungen für die Palladiumbestimmung vor, wenn Lanthan als spektroskopischer Puffer zugesetzt wird. Korrekturgleichungen werden gegeben.
    Notes: Abstract The atomic-absorption determination of Pd is not affected by Pt, but there is a small influence by Rh. The aim of this investigation is to determine these effects quantitatively, furthermore under the releasing effects of uranium and lanthanum. Equations to correct the results are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 278 (1976), S. 203-206 
    ISSN: 1618-2650
    Keywords: Best. von Blei, Cadmium in Wein ; Spektralphotometrie, Atomabsorption ; Extraktionsmethode
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The insolubility of sugars and fruit acids in MIBK allows the direct extraction of heavy metals by APDC from wine and similar products. With special precautions an accuracy of /+-5% can be obtained for Pb and Cd in the concentration range from 0.1–1 ppm and 1–10 ppb, respectively. Together with our experiences a brief survey of the most recent literature is also presented.
    Notes: Zusammenfassung Die Unlöslichkeit der Zucker und Fruchtsäuren in MIBK erlaubt die Direktextraktion von Schwermetallionen mittels APDC aus Wein und ähnlichen Produkten. Unter Beachtung besonderer Vorsichtsmaßnahmen wird für Pb im Bereich von 0,1–1 ppm und für Cd im Bereich 1–10 ppb eine Genauigkeit von ± 5% erhalten. Gleichzeitig wird zusammen mit unseren Erfahrungen ein kurzer Überblick über die neueste Literatur gegeben.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 281 (1976), S. 201-209 
    ISSN: 1618-2650
    Keywords: Best. von Selen in Kupfer ; Chromatographie, Gas ; Reinstkupfer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur Bestimmung geringster Selengehalte in Reinstkupfer erhitzt man die Probe (≤2 g) in einem Quarzrohr im Sauerstoffstrom auf 1100–1150°C. SeO2 verdampft und wird quantitativ gesammelt, indem man es zusammen mit dem Trägergas durch Kühlung mit flüssigem Stickstoff in einer Mikrovorlage kondensiert. Nach Abdampfen des Sauerstoffs setzt man es in der Vorlage mit 4-Nitro-o-phenylendiamin zu 5-Nitropiazselenol um, das nach Ausschütteln in Toluol direkt gas-chromatographisch (ECD) im ppb-Bereich bestimmt wird. Nach Optimierung aller Verfahrensschritte mit Hilfe von 75Se ergaben sich ausgezeichnete Gütedaten; Standardabweichung: ± 0,004 ppm für 0,74 ppm Se, 15 Bestimmungen, 200–600 mg Einwaage; Nachweisgrenze : 1 ppb Selen.
    Notes: Abstract For the determination of the smallest amounts of selenium in high-purity copper, the sample (≤2 g) is heated in a quartz tube at 1100–1150°C. SeO2 evaporates and is collected quantitatively by condensation of the carrier gas in a micro-trap cooled with liquid nitrogen. After evaporation of the oxygen, SeO2 is caused to react in the trap with 4-nitro-o-phenylenediamine, forming 5-nitropiazselenol, which is then extracted with toluene and determined in the ppb-range by gas-chromatography with ECD. All separation steps were optimized by the tracer method using 75Se. Determining 0.74 ppm of Se, the standard deviation was found to be 0.004 ppm for 15 determinations with samples of 200–600 mg. The detection limit is 1 ppb of Se.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 282 (1976), S. 17-19 
    ISSN: 1618-2650
    Keywords: Best. von Elementen ; Chromatographie, Gas ; Diäthyldithiocarbamate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur anorganischen Multielementanalyse ist die Gas-Chromatographie von Diäthyldithiocarbamaten geeignet. Mit einem FID können bereits Kationen im 0,6–0,06 ppm-Bereich nach Ausschütteln der wäßrigen Lösungen bestimmt werden. Di(trifluoräthyl)dithiocarbamate zeigen noch höhere Flüchtigkeiten. Eigenschaften und gas-chromatographisches Verhalten einiger dieser Chelate werden angegeben.
    Notes: Abstract For inorganic multielement analysis gas chromatography of the diethyldithiocarbamates is properly suited. Cations in the concentration range of 0.6–0.06 ppm can be determined even with the aid of a FID after extraction from aqueous solutions. Di(trifluor-ethyl)dithiocarbamates show higher volatilities. Properties and gas chromatographic behaviour of some of these chelates are described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...