ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
  • 2
    Publication Date: 1979-01-01
    Print ISSN: 0016-1152
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
  • 4
    ISSN: 1618-2650
    Keywords: Best. von Selen in Anorgan. Material, Organ. Material ; Spektrometrie, Atomabsorption ; Verdampfung im dynam. System
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird eine spezielle Apparatur zur Abtrennung von Selengehalten aus anorganischen (≥ 0,5 ng/g) und organischen (≥ 2 ng/g) Matrices beschrieben, die eine zuverlässige Bestimmung der isolierten Selenspuren durch Hydrid-AAS (HG-AAS) bzw. AAS mit elektrothermischer Atomisierung (ETA-AAS) ermöglicht. Beim Aufschluß der Probe im O2- bzw. Ar/O2-Trägergasstrom wird das Selen in einem Quarzsystem als SeO2 verflüchtigt und in einer Vorlage zusammen mit dem Sauerstoff und anderen flüchtigen Substanzen durch Kühlen mit flüssigem Stickstoff kondensiert. Die Leistungsfähigkeit des Verbundverfahrens wird durch zahlreiche Se-Bestimmungen in Metallen, Gesteinen, Sedimenten, Böden, pflanzlichen und tierischen Matrices belegt.
    Notes: Summary A special apparatus for the separation of low levels of selenium from inorganic (≥ 0.5 ng/g) and organic (≥2 ng/g) matrices is described. It enables a reliable determination of the isolated traces of selenium by hydride-AAS (HG-AAS) or AAS with electrothermal atomisation (ETA-AAS). During decomposition of the sample in a stream of O2 or Ar/O2 in a quartz system, selenium is volatilized as SeO2 that is subsequently trapped simultaneously with oxygen and other volatile substances by cooling with liquid nitrogen. The capability of this multi-stage procedure is proved by numerous determinations of Se in metals, rocks, sediments, soils, plant and animal matrices.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1618-2650
    Keywords: Best. von Selen in Kupfer, Silber, Gold, Blei, Wismut ; Atomabsorptionsspektrophotometrie ; Graphitofen, ppb-Bereich
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung In einem relativ einfach durchzuführenden Verbundverfahren wird Selen im Sauerstoff-strom innerhalb 15 min bei 1100–1150°C quantitativ aus den Metall- bzw. Metalloxidschmelzen verdampft und in einer mit flüssigem Stickstoff gekühlten Vorlage aufgefangen. Das aus der Vorlage mit einer definierten Menge verdünnter HNO3 in Gegenwart von Ni-Nitrat gelöste Selen läßt sich direkt durch AAS mit dem Graphitofen (FAAS) äußerst nachweisstark und zuverlässig bestimmen. Die Nachweisgrenze (elektrodenlose Entladungslampe) liegt bei 3×10−11 g Se. Der Verfahrensverbund erlaubt mit Probenmengen ≤10 g in Ag und Au Se-Gehalte ≥0,05 ppb,inCu ≥0,1 ppb,in Bi ≥ 0,2 ppb und in Pb ≥ 10 ppb zu erfassen. Für draht-, stab- und spanförmige Proben erhält man für Se-Gehalte von 2–0,002 ppm Variationskoeffizienten zwischen 3 und 6%. Die Vollständigkeit der Se-Verdampfung aus den Matrices Cu, Ag, Au und Bi wurde ebenso wie die Richtigkeit des Gesamtverfahrens durch systematische Untersuchungen belegt.
    Notes: Summary Selenium is evaporated in a multi-stage procedure within 15 min from metals or metal oxides fused at temperatures of 1100–1150°C under a stream of oxygen and is trapped in a receiver cooled with liquid nitrogen. The condensed SeO2 is dissolved with a definite volume of diluted HNO3 in the presence of Ni-nitrate and determined with high sensitivity and reliability by FAAS (electrodeless discharge lamp). The detection limit of the FAAS was found to be 3 · 10−11 g of Se. The multi-stage procedure allows to detect Se levels ≥ 0.05 ppb in Ag and Au, ≥ 0.1 ppb in Cu, ≥ 0.2 ppb in Bi, and ≥ 10 ppb in Pb, respectively, with sample weights ≤ 10 g. For wire, rod, and chip samples the coefficients of variation are found to be between 3 and 6% for Se contents of 2 to 0.002 ppm. The quantitative evaporation of Se from Cu, Ag, Au, and Bi as well as the accuracy of the whole procedure have been checked systematically.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 337-344 
    ISSN: 1618-2650
    Keywords: Best. von Selen ; Spektralphotometrie, Atomabsorption ; Spuren, Hydrid, Elementquerstörungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Natriumborhydrid-Reduktionsmethode zur Austreibung des Selens aus sauren Probenlösungen in Kombination mit einer AAS-Bestimmung des Selens in einer geheizten Quarzküvette (Hydridsystem MHS-1 der Firma Bodenseewerk Perkin-Elmer, Überlingen) wird durch die Gegenwart zahlreicher Begleitelemente selbst im Spurenbereich gestört. Bei der Bestimmung von 5–100 ng Se in 20 ml 0,3 N salzsaurer Probenlösung verursachen ca. 0,7 μg Ag+;1,5 μg Sb3+;3 μg Au3+; 5 μg Cu2+; 6 μg As3+; 25 μg Sb5+; 30 μg As5+; 60 μg Ni2+; 200 μg Pt4+ bzw. Mn7+; 700 μg Co2+; 1,5 mg Pb2+; 3 mg Cr6+ und 5 mg Hg2+ jeweils Erniedrigungen des Se-Signals um 50%. 4 μg Sn2+/Sn4+ bzw. 6 μg Bi3+ führen zu einer 30 %igen Erniedrigung. Fe2+/Fe3+ stören ab Mengen ≥400 μg. Te4+ ≤ 300 μg, Alkali- und Erdalkalimengen≤25 mg sowie Mengen ≤ 5mg Al3+, Cr3+, Mn2+ und Zn2+ waren ohne Einfluß auf die Ausbeute der Selenhydrid-Bildung. Die Störungen sind stark abhängig von der vorgegebenen HCl-Konzentration in der Probenlösung. Weitere Quellen für systematische Fehler des Verfahrens wurden untersucht und teilweise behoben. Das Hydrid-AAS-Verfahren kann nicht zur direkten Bestimmung von Selenspuren (ng/g-Bereich) in metallischen, geologischen und biologischen Matrices empfohlen werden, wenn die Gehalte der störenden Begleitelemente in der Probe bestimmte Grenzkonzentrationen überschreiten, die numerisch stark von der apparativen Anordnung und den Versuchsparametern abhängen.
    Notes: Summary The sodium boro hydride-reduction method for the liberation of selenium from acid sample solutions in connection with its determination by AAS using a heatable optical cell made of quartz (hydride system MHS-1, Bodenseewerk Perkin-Elmer, Überlingen, F.R.G.) is interfered with by numerous concomitant elements occurring even in the trace range in the sample solution. In the determination of 5–100 ng of selenium in 20 ml sample solution 0.3 N in HCl, 0.7 μg of Ag+; 1.5 μg of Sb3+; 3 μg of Au3+; 5 μg of Cu2+; 6 μg of As3+;25 μg of Sb5+; 30 μg of As5+; 60 μg of Ni2+; 200 μg of Pt4+ and Mn7+; 700 μg of Co+; 1.5 mg of Pb2+; 3 mg of Cr6+ and 5 mg Hg2+ cause a depression of the Se-signal of 50%. 4 μg of Sn2+/Sn4+ and 6 μg of Bi3+ cause a depression of 30%. Fe2+ /Fe3+ interfere only if present in quantities ≥400 μg. Te4+ in quantities ≤300 μg, alkali metals and alkaline earths ≤25 mg, and Al3+, Cr3+, Mn2+ and Zn2+ ≤5 mg do not affect the selenium hydride formation. The interferences depend very strongly on the used HCl concentration in the sample solution. Further sources of systematic errors are investigated and partly eliminated. The hydride-AAS procedure cannot be recommended for the determination of traces of selenium (ng/g-range) directly in metallic, geological or biological matrices, if the levels of the interfering concomitants reach above a certain threshold concentration, which numerically depend strongly on the apparatus and the parameters of the analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...