ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (393)
  • Gas chromatography  (393)
  • Wiley-Blackwell  (285)
  • Springer  (108)
  • Annual Reviews
  • 2015-2019
  • 1980-1984  (393)
  • 1935-1939
Collection
  • Articles  (393)
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Entomologia experimentalis et applicata 34 (1983), S. 20-26 
    ISSN: 1570-7458
    Keywords: Dioryctria abietella ; Cone pyralid ; Lepidoptera ; Pyralidae ; Sex pheromone, (Z,E)-9,11-tetradecadienyl acetate ; Single sensillum recordings ; Electroantennography ; Gas chromatography ; Mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Résumé L'analyse en chromatographie gazeuse associée à une détection électroantennographique a montré que l'acétate (Z,E)-9,11-tétradécadiényle (Z,E)-9,11–14:Ac est l'un des composants de la phéromone de Dioryctria abietella Schiff (Lepid.: Pyralidae). Couplage chromatographie en phase gazeuse spectrometrie de masse a montré la présence d'acétate tétradécadiényle avec un spectre de masse et un indice de rétention identiques au Z,E-9,11–14:Ac Un récepteur cellulaire sensible à la fois au Z,E-9,11–14:Ac et à un extrait de la femelle a été identifié sous l'antenne du mâle. Les analyses des antennogrammes et de la cellule isolée ont étayé la caractérisation du composant de la phéromone comme étant Z,E-9,11–14:Ac. Un récepteur cellulaire additionnel sensible à l'acétate (Z.)-9-tétradécadiényle et à l'acétate (Z.E.)-9,12-tétradécadiényle a été trouvé sur l'antenne du mâle, mais il n'était pas activé par l'extrait de la femelle. Sur le terrain Z,E-9,11–14:Ac, présenté seul, attirait des nombres importants de mâles de D. abietella. L'addition de l'acétate (Z)-9-tétradécényle a inhibé l'attraction des mâles par les pièges.
    Notes: Summary Gas chromatographic analyses coupled with electro-antennographic detection indicated that (Z,E)-9,11-tetradecadienyl acetate (Z,E-9, 11–14:Ac) is a pheromone component of the cone pyralid Dioryctria abietella. Gas chromatographic-mass spectrometric analyses confirmed the presence of a tetradecadienyl acetate with mass spectrum and retention index identical to Z,E-9,11–14:Ac. A receptor cell sensitive to both Z,E-9,11–14:Ac and the female extract was identified on the male antenna. An additional receptor cell sensitive to (Z)-9-tetradecenyl acetate and (Z,E)-9,12-tetradecadienyl acetate was found on the male antenna but was not activated by the female extract. In the field Z,E-9,11–14:Ac presented alone attracted significant numbers of male D. abietella. Addition of (Z)-9-tetradecenyl acetate inhibited the attraction of males to traps.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 651-660 
    ISSN: 1612-1112
    Keywords: Capillary columns, glass ; Gas chromatography ; Column preparation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Glass capillary column chromatography is the most rapidly growing part of gas chromatography. There are many complex new analytical tasks and they require special capillary columns. Fortunately there is a wide range of column preparation methods available, and they make the preparation of glass capillary columns a more varied job than that of packed columns. In this paper these methods are reviewed and suggestions are given for making task-oriented columns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Configuration ; Chiral phases ; Gas chromatography ; Isovaline
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The D-(resp. R) configuration of isovaline (=2-ethylalanine) was proved for the peptide antibiotics antiamoebin, Tü 165 (CBS 382.62), stilbellin, samarosporin (=emerimicin IV), suzukacillin B (A), trichotoxin A-40 and A-50. This contradicts the previously reported L-configuration for isovaline in antiamoebin and emerimicin IV. The configuration was determined by GC of the N-trifluoroacetyl-isovaline n-propyl ester on glass capillary columns coated with the chiral stationary phase N-propionyl-L-valine tert.-butylamide polysiloxane (Chirasil Val). The D-configuration of the isovaline from trichotoxin A-40 was also established independently using GC of N-pentafluoro-propionyl-isovaline (+)-3-methyl-2-butyl esters on glass capillary columns coated with OV 17.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 601-602 
    ISSN: 1612-1112
    Keywords: Ethanolamines ; Ethylene glycols ; Direct separation ; Gas chromatography ; Short glass capillaries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An effective and rapid GC separation of ethanolamines, even in the presence of ethylene glycols, using short glass capillary columns is developed. No preliminary derivatisation of the sample is necessary. The separation is completed in 6 minutes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 143-147 
    ISSN: 1612-1112
    Keywords: Capillary columns ; Gas chromatography ; Retention index ; Structure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention index of twenty different homologous series of esters have been determined experimentally on polar (Carbowax 1540) and non-polar (squalane) columns. General equations to calculate retention index have been established by statistical methods. The influence of the length and inductive effect of acid and alcohol chains and the relative position of the carboxylic group are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 285-288 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Porous layer open tubular columns ; Kaolin as support ; Column performance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary PLOT columns have been prepared with kaolin as the liquid phase support. These columns show good efficiency with different stationary phases and good thermal stability with polar phases. The performance of columns is shown by the separation of various mixtures such as fatty acids, phenols and anilines which are of analytical importance.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Urea herbicides ; Catalytic hydrolysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the rapid catalytic hydrolysis of phenylurea herbicides on silica gel at elevated temperatures. After derivatisation of the anilines produced with heptafluorobutyric acid anhydride final analysis is done on a gas chromatograph equipped with an electroncapture detector. Detection limits are in the 1–5 picogram range. The method has successfully been applied to residue analysis of water samples at the 1 ppb level. The determination of free anilines present in water samples and the potential of various techniques to be used to discriminate between free anilines and parent herbicides are also discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Teflon capillary columns ; Chemically modified teflon ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation of teflon capillary columns employing direct coating of the stationary phase to the chemically modified teflon surface and the role of the chemically modified teflon in the separation mechanism are described. Two types of contributions from the modified teflon have been observed: nonspecific adsorption of the carbon surface and specific interactions of polar groups in the carbon skeleton. The use of polar liquid phases can eliminate adsorption due to the presence of polar groups in the modified teflon.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Van der Waals' volume ; Polarity of stationary phase ; Retention index
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Equations for Retention Index (I) versus Van der Waals, volume (Vw) on squalane are studied for alcohols, carbonyls, esters and ethers. Each equation includes linear and branching substances with different positions of the functional group in the carbon chain. The study is extended to stationary phases with polarities from 4.29 to 91.54 on the Tarjan et al. scale. Variations of the slope and origin ordinate values with the polarity of the stationary phase are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 125-132 
    ISSN: 1612-1112
    Keywords: Capillary columns ; Fast analysis ; Gas chromatography ; Instrumental effects ; Optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The efficiency of fast GC columns depends largely on the quality of the chromatograph. A theoretical and experimental study shows the relative importance of the various phenomena involved and permits the optimization of a GC System. Extremely good performances, exceeding 2,500 plates per second have been routinely obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 351-354 
    ISSN: 1612-1112
    Keywords: Supported catalysts ; Reserved-flow GC ; Drying step ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Application of reversed-flow gas chromatography to study the drying step in the preparation of supported catalysts is proposed. It is demonstrated that this technique can be applied to investigate the kinetic law followed, as well as to obtain kinetic parameters of drying (rate constants, activation energies and frequency factors). Amaterial illustrating this application is γ-Al2O3 impregnated with usual organic solvents (n-C5H12,n-C6H14,n-C7H16, CH3COCH3 and CH3CH2OH). It was found that in all cases above a simple first-order law based onone kind of active site is followed. Moreover, it was observed that the activation energyE a of the drying process increases almost linearly with the relative molecular mass of the solvent, whereas for the same solventE a increases with the amount used. The operation of a kinetic compensation effect suggests “similar” activated complexes of the various solvents used.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Fused silica capillaries ; Capillary drawing ; Glass capillaries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A compact description is given of a simple and reliable method of drawing flexible fused silica capillary for gas chromatography. Some emphasis is given to the fact that the practices of drawing optical fibres should not be followed too slavishly so this leads to unnecessarily complicated and expensive equipment. Satisfactory capillary column silica tubing can be made with straightfoward extension of the method developed earlier for drawing thick walled capillary. A simple glass/silica hydrogen oxygen diffusion flame bumer is described for fusing the preform tubing at the draw point which is enclosed by a water cooled glass enclosure to trap evaporated silica and maintain the operation under dust free conditions. The uniformity of the capillary diameter is better than 5% which is adequate for most gas chromatographic purposes. The second part of the paper yet to be published will cover the methods developed for coating the capillary both internally and externally.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 567-571 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Helium detector
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Four main factors which determine the shape and the polarity of the helium detector signal are discussed. All possible responses of this detector, both in elution and in vacancy chromatography, are presented and special attention is drawn to the intermediate region. The idea of ionization vacancy is introduced for the specific case of two components which are unresolved by the column and to which the detector responds with different sensitivity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 574-575 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Xylenol isomers ; Sugar derivatives as liquid phases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Adenosine, guanosine and inosine used as liquid phases in gas chromatography permits the separation of all six xylenol isomers.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Polycyclic aromatic hydrocarbons ; Retention index ; Average molecular polarizabilities
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A significant correlation has been found between the retention indices of polycyclic aromatic hydrocarbons on non-polar stationary phases and the average molecular polarizabilities of the molecules separated on these phases. Equations have been derived for the determination of the average molecular polarizabilities, directly from the retention indices.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 69-72 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Polynuclear aromatic hydrocarbons ; Retention index ; Vapour pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention index of a planar polynuclear aromatic hydrocarbon on the GC phases OV-101, SE-52, and OV-17 is strictly related only to the boiling point, and less closely to the relative molecular mass. The very approximates relation with connectivity index ins only a consequence of the latter. On a nematic lqiuid crystal phase, a variation of activity coefficient, expressed in terms of a shape factor, also influences the retention of PAH.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 269-276 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Detector performance ; Trace analysis ; Catalytic conversion ; Multidimensional gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Relationships are derived describing how the detection limit of a chromatographic system depends on the minimum detectable limit of the detector and the chromatographic parameters such as column length, efficiency, carrier gas flow rate and the capacity factor. Performance data of detectors developed in the last 25 years at the Dalian Institute of Chemical Physics of the Chinese Academy of Sciences are given and a few selected application examples are listed. These include trace analysis by preconcentration and by direct analysis and the utilization of multidimensional gas chromatography with two columns, two detectors, a 12-port valve, and a catalytic conversion reactor.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1612-1112
    Keywords: Gas chromatography ; C1−C5 Hydrocarbons ; Dimethyl ether
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An analytical GC method was developed which uses a single packed column consisting of three packings in series prepared with the following liquid phases: dimethyl sulfolane, propylene carbonate, and silver nitrate. This system provides satisfactory resolution of mixtures of C1−C5 hydrocarbons and dimethyl ether obtained when converting methanol to gasoline. Due to the high capacity of the column it is possible to inject larger sample amounts permitting trace analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 1612-1112
    Keywords: Phthalides ; Umbelliferae ; Liquid-solid chromatography ; Gas chromatography ; Ligustilide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A liquid-solid chromatographic pre-fractionation of naturally occurring phthalides has been developed. The LSC was carried out on a column of silica applying a 1–50% gradient elution of diethyl ether (containing 2% methanol) in pentane. The enrichment in the fractions led to better possibilities for a gas chromatographic separation and isolation allowing further studies by spectroscopic methods. Ligustilide may easily isomerize during GC as a result of ageing of the column.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 30-32 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Arsenic ; Inorganic materials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the quantitative chlorination and extraction of arsenic as arsenic trichloride from a number of alloys. The conditions for the quantitative gas chromatographic measurement of the volatile chloride have been studied. The proposed method for inorganic materials is very fast giving results within 10 min; sensitive, 1.5·10−13 g As can be detected, simple and accurate. At the ng level of As the error is about 20% with a standard deviation less than 20%, and at the 10pg level the error is about 36% with a standard deviation of 44%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 765-768 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Preparative scale chromatography ; Capacity ; Dual-stage separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The capacity of different versions of single- and dual-stage separation of mixtures on a preparative scale is considered. It has been shown that dual-stage separation with intermediate condensation considerably enhances the capacity of the installation as compared with a single-stage process.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 117-124 
    ISSN: 1612-1112
    Keywords: Various packed GC column ; Gas chromatography ; Porous layer beads ; GC/MS analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Theoretical comparisons of various packed GC column types are presented with respect to analysis time, efficiency, sample dilution, and sample capacity for a given maximum inlet pressure. In particular, totally porous particles, porous layer beads, and glass beads are compared with one another. It is shown that 30 μm porous layer beads offer a useful compromise between analysis time and plate count with relatively good sample capacity. Moreover, when using 1 mm i.d. columns (microbore), outlet flow rates that are reasonable for direct coupling to magnetic sector mass spectrometers are achieved making these columns suitable for GC/MS. Using 30 μm Zipax porous layer beads, columns yielding 8,000 to 10,000 plates/meter have been produced with inlet pressures of 13 to 26 atm. A simple modification of the injection port converts the maximum inlet pressure of a commercial gas chromatograph to 26 atm. With such pressures, columns in excess of 20,000 plates can be achieved. Chromatograms are presented illustrating the promise of these microbore columns for GC and GC/MS analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 245-248 
    ISSN: 1612-1112
    Keywords: Chromatoscopy ; Gas chromatography ; Graphitized carbon black ; Molecular structure and retention ; Aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A molecular-statistical calculation of the retention volumes at zero sample size on graphitized thermal carbon black is carried out for quasi-rigid molecules of fluorene, indene, 1-methylindene, 2-methylindene and three dimethylindenes. A reasonable agreement is observed between the calculated and the available experimental gas chromatographic data. The potential barrier to internal rotation and the torsional angle in styrene molecules are estimated by comparing theoretically calculated and measured retention volumes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Silicone liquid phases ; Oxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The on-column oxidation of apolar and polar silicones used as gas chromatographic stationary phases is investigated. Even at 225° the effects of oxidation are found to be slight. Of the materials investigated the methylphenylsilicones are the most stable.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    ISSN: 1612-1112
    Keywords: Glass capillary ; Gas chromatography ; Methyl chloroacetates ; Methyl chloropropanoates ; Methyl chlorobutanoates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas chromatography of all chlorinated methyl acetates, methyl propanoates and methyl mono- and dichlorobutanoates has been studied on Carbowax 20M and SE-30 glass capillary columns under various running conditions. The order of elution on a non-polar column was largely determined by the boiling point of esters, whereas on a polar column it was much influenced by the structure of compounds. Complete separation of the combined mixture of all 27 compounds could not be achieved, however, methyl 3,3-dichlorobutanoate was the only ester overlapped on both columns in spite of the various column temperatures used. The best separation of the mixture was on Carbowax 20M with a temperature program from 50°C at 8°C/min, isothermal running conditions leading either to poor separation of volatile components or long analysis time and broad peaks of higher chlorinated esters. The relative retention times for compounds at the various column temperatures are given and the retention order on a polar and on a non-polar column discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 517-520 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carbon-silica adsorbents ; n-Octadecanol film ; Phase transitions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The properties of the n-octadecanol film on carbon-silica adsorbent (Carbosil) were investigated. It was found that n-octadecanol forms an oriented film on the Carbosil's surface. If the surface of the basic silica gel is not completely covered with carbon, then the phase transition takes place in this film at a temperature higher than the melting temperature of n-octadecanol. One may distinguish two forms of this film, characterised by the different structures and the temperatures of the phase transitions. The first exists on the surface of silica gel unblocked by carbon. This part of the film is a monolayer, in which the alcohol molecules are vertically oriented. The solid compact-liquid expanded type phase transition at the well-defined temperature occurs in this film. In the second part of the film formed on the carbon surface, there is a multilayer of n-octadecanol. Its molecules are probably parallely oriented in relationship to the adsorbent surface. This film desintegrates progressively when the temperature increase. Maximum temperature of this phase transition is lower than the temperature of its analogue on pure silica gel surface.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 546-558 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Quantitative analysis ; Sample inlet systems ; High-speed analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The attainment of precise quatitative analytical data using open-tubular (capillary) columns in standard, commercially available gas chromatographic instrumentation is demonstrated. Key elements in the design and proper utilization of the instrumentation are discussed. The function of the various sample introduction systems is elaborated and their quantitative performance demonstrated. The extra-column contribution to band-spreading is determined and the resultant data is used assessing the suitability of commercial instrumentation for highspeed capillary gas chromatography. The quantitative analysis of a sample containing some eleven components in less than thirty seconds is shown.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Crystal hydrates as stationary phases ; Mobile Phases containing water ; Selective retentions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of crystallohydrates, crystallohydrate solutions and melts as stationary phases in gas chromatography has been proposed. Crystallohydrates have been shown to display high selectivity in the separation of polar organic compounds when use is made of water vapours as the mobile phase. Some aspects of gas-liquid chromatography in water vapours and with the stationary phase comprising crystallohydrates have been studied, and the preliminary results obtained point to the desirability of further progress in this field.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 201-203 
    ISSN: 1612-1112
    Keywords: Phenols ; Whisky ; Gas chromatography ; Aroma compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Twelve volatile phenols were identified in whisky by combined gas chromatography-mass spectrometry. Of these phenols 2,4-dimethylphenol was found for the first time in the aroma of whisky. The content of phenol, o-, m-, and p-cresol, guaiacol, p-ethylphenol, p-ethylguaiacol and eugenol in whiskies originating from different countries was determined by gas chromatography as their 2,4-dinitrophenyl ethers using electron capture detection. The results show that Scotch whiskies differ from others in the content of o-, m-, and p-cresol. The odour threshold values of phenols studied were determined in a 10% (v/v) ethanol-water mixture and in some cases also in the whiskies. Cresols have been found to make contribution to the aroma of Scotch whisky.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 26-31 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Ionization detectors ; Gaia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper is an account of the development of the gaia hypothesis as seen through the eyes of a gas chromatographer. Gaia is a radical notion about the Earth which postulates the climate and chemical composition to be regulated at an optimum by and for life. Gas chromatography played an important role in the gathering of evidence for the hypothesis but most significantly the art of inventing detectors lead to the developement of a planetary life detector through which gaia was revealed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 282-285 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Naphtha analysis ; Gasoline analysis ; Hydrocarbon type analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two different gas chromatographic methods are used for the determination of hydrocarbon type distribution in naphtha and gasoline samples with final boiling points up to 275 °C. The methods are based either on a single capillary column or on a valve-switched packed column system. Both methods give extensive information on paraffins, olefins, naphthenes and aromatics in total as well as by carbon-number. In each case the analysis is fully automated with a computer controlling the entire analysis from injection to results presentation. The advantages and limitations of both methods are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 322-324 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Graphitized carbon black supports ; Determination of hydroxyacids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Acid-washed graphitized carbon black (Carbopakc B) modified with trimesic adic and PEG 20M has proved to be effective for quantitative analysis of underivatized low molecular weight hydroxyacids. Calibration data revealed good linear relationships between relative peak area and concentration for lactic and 3-hydroxybutyric acids down to 0.05 mmol/l. The packing material was suitable for the analysis of aqueous solutions of hydroxyacids as it is tolerant to injections of water over a prolonged period of use. The GC system developed has been applied to the analysis of some hydroxyacids of biomedical interest in blood plasma and lactic acid contained in wine and beer.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Modified thermal energy analyzer ; Selective detection of nitrogen compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modification to the TEATM Analyzer is described, which allows it to be used as a highly selective GC detector for nitrogen compounds as well as for N-nitrosamines and nitro compounds. The modified Analyzer is as sensitive as the AFID, but has a much higher selectivity towards nitrogen compounds than the AFID. Its response appears to be molar, with an output that is dependent only on the number of nitrogen atoms present. The performance of the modified Analyzer for the analysis of ammonia, amines,N-nitrosamines, nitriles and organonitro compounds is reported and discussed, as is its application to the detection of these compounds in bacon and beer samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 33-36 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Preparative scale chromatography ; Capacity ; Dual-step separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The capacity of dual-step preparative chromatographic separation systems is considered. It is shown that dualstep separation makes it possible to enhance the capacity of preparative installations as compared with single- and dual-stage purification of the compounds.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 44-46 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Natural gas analysis ; Poropak N
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple gas chromatographic method is described for the rapid analysis of natural gas using thermal conductivity detectors and programmed-temperature operation of a single Poropak N column. The method permits the determination of nitrogen, carbon dioxide and hydrocarbons containing one to seven carbon atoms.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 553-559 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Immobilized liquid phases ; Thick-film columns ; Diffusion coefficients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The influence of the liquid phase film thickness in open-tubular (capillary) columns on the individual resistance-to-mass-transfer terms and on the overall column efficiency is examined from the theoretical point of view. Methods for the calculation of the diffusion coefficients are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Immobilized liquid phases ; Thick-film columns ; GC-FTIR
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The performance of a column prepared with an immobilized (chemically bonded) methylsilicone phase having a film thickness of 5μm is investigated in detail. Due to their high sample capacity, such columns are particularly useful when directly coupling gas chromatography with spectroscopic techniques such as Fourier-transform infrared spectroscopy. Thick-film columns can even be used with thermal conductivity detectors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 600-604 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Alkyl benzenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The additivity concept in the retention index system of Kovats has been examined for a series ofn-alkylbenzenes and theiro- andp-monosubstituted nitro-, amino-, and chloro-derivatives. Anomalous behaviour is exhibited by the first three members of the series on both polar and non-polar stationary phases. For addition of a methylene group ton-propylbenzene or ap-substituted derivative, it is found that the retention increment, Δl CH2, approaches 100 units. However, the strong inductive effect of the group in the ortho position and the steric effects apparent in ano-substituted alkylbenzene lead to large variations of retention increment upon addition of-CH2-to the alkyl chain. A study ofn-alkylbenzene retention on Apiezon L and Carbowax 20M over a wide range of temperatures has verified the linearity of the retention increment with temperature and has revealed that this gradient increases with increasing carbon side-chain length for the first few members of the series, thereafter becoming constant. Functional retention increments, Δlx, for substitution of nitro-, amino- and chloro-groups into the benzene ring are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 691-692 
    ISSN: 1612-1112
    Keywords: Dichlorophenol isomers ; Sodium benzenesulfonate ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary It is difficult to separate all the dichlorophenol isomers as free phenols by gas-liquid chromatography. However they were effectively separated on 4,4′-dimethoxyazoxybenzene (liquid crystal), and all the isomers were separated appreciably well on sodium 1-naphthalenesulfonate, 2-naphthalenesulfonate and dodecylbenzenesulfonate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 65-69 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Oxygenates ; Fused-silica capillary columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method of analysing gasolines that contain oxygenates has been developed. The method uses a single fusedsilica capillary column and gives quantitative data for the oxygenates and the hydrocarbons in one analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Trace analysis ; GC-concentration ; Enrichment factor ; Theoretical evaluation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Based on gas chromatographic retention data obtained on a given adsorbent and at a given trap efficiency at different temperatures new equations are proposed for the evaluation of the enrichment factor. These equations are suitable under various preconcentration conditions such as: equilibrium saturation, complete trapping and permissible losses. Compared to known expressions for the evaluation of the enrichment factor the equations suggested consider the band broadening of the impurity in a trap causing a loss of the substance at the adsorption stage and dilution of the sample during desorption when the desorbed impurities are directed into the gas chromatographic column without intermediate freezing out in an graphic column without intermediate freezing out in an empty tube. The new equations may be used to select the optimum preconcentration conditions providing the necessary sensitivity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 191-194 
    ISSN: 1612-1112
    Keywords: Thermal treatment of MgO and MgCO3 ; Adsorption properties ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The changes in the chromatographic properties of MgO and MgCO3 due to thermal treatment was investigated. The experimental results show that thermally treated MgO and MgCO3 can be used as stationary phase for the gas-adsorption chromatography of hydrocarbon mixtures.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    ISSN: 1612-1112
    Keywords: Esterification in aqueous solution ; n-Butyl esters of fatty acids ; Gas chromatography ; Fatty acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The esterification of C1−C8 fatty acid in aqueous solutions and in the presence of sulfuric or hydrochloric acid and with n-butanol is described. It has been established that the esterification can be used for the quantitative determination of these fatty acids in the concentration ratio range of [H2O]/[n-BuOH]=0.01–5.3. In the concentration ratio range of 0.01–0.8 the water present does not interfere. In the concentration range of above 0.8 anhydrous sodium sulfate is used for binding the water, in the amount of [Na2SO4.anh.]/[H2O]≥0.2.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 472-476 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid stationary phase ; Liquid phase bleeding
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The theory of the evaporation of the liquid stationary phase is elaborated and experimentally verified. On the basis of this theory the role played by the losses in the amount of liquid phase present is quantitatively determined. General techniques are examined which minimize the losses; these techniques are based on saturating the incoming carrier gas with liquid phase vapours and raising the pressure of the carrier gas in the column, e.g. by connecting a capillary to the column outlet in order to offer resistance to the gas flow. The application of these techniques ensures stable performance of the gas chromatographic columns using a volatile liquid phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    ISSN: 1612-1112
    Keywords: Esterification in aqueous solution ; iso butyl esters of C1–C20 fatty acids ; Gas chromatography ; Fatty acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary C1–C20 carboxylic acids have been esterified in aqueous solutions with i-butanol. Gas chromatographic analyses have been performed from a single chromatogram. It has been established that esterification in the concentration range of [H2O]/[i-BuOH]=0.01–10.3 can be utilized for the quantitative determination of these carboxylic acids. The presence of water does not interfere in the range of [H2O]/[i-BuOH]=0.01–1.03. In the cases of [H2O]/[i-BuOH]〉1.03, anhydrous sodium sulfate has been used for binding the water, in an amount of [Na2SO4]anh./[H2O]≥0.2.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Cross-linked Stationary phase ; Immobilized Stationary phase ; Packed columns ; Trapping
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A coating of silicone SE-54 on Chromosorb W has been converted to an analytically stable, immobilized stationary phase layer by cross-linking with an organic peroxide. Up to 10% by weight has been applied in this manner. Excellent high temperature qualities are exhibited, such as low bleeding and good base line stability, during typical analyses. Poly (2,6-dimethyl-p-phenylene oxide) has also been crosslinked as a surface coating on Chromosorb W with an organic peroxide. From 3 to 4% by weight has been immobilized in this way. The resultant packing material, following high temperature conditioning, has been examined for use as an adsorbent of trace substances, similar to the applications to which such adsorbents as Tenax GC have commonly been applied, e.g. trace analysis of air. It appears to exhibit satisfactory properties for this analytical purpose.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 21-22 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Isopropylidene-glucose ; Glucose ; GC of TMS-derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper describes the gas chromatographic separation of the mixture of di- and mono-O-isopropylidene-D-glucose and D-glucose as their trimethylsilyl derivatives. The use of OV-101 as liquid phase provides a complete separation for the all components in the mixture. Quantative analysis was performed using xylitol as the internal standard for di- and mono-O-isopropylidene-D-glucose, and sorbitol as the internal standard for α-and β-glucose.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Nuclear magnetic resonance ; Terpenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure is described for recording1H NMR spectra of flowing gaseous GC fractions boiling as high as 200°C. The line width of the signals in the NMR spectra is smaller than 2.2Hz.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 556-559 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid chromatography ; Tetramethrin ; Residues
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the analysis of tetramethrin aqueous formulation and residues of tetramethrin on woolen cloth. The samples were extracted with acetonitrile and partitioned with benzene. Interferences were removed by liquid column chromatography with acid alumina and eluted with 10% ethyl acetate-hexane. Analysis was by gas chromatography with a 10% UCW98 (methylsilicone) column. Detection was made with the flame ionization detector to avoid the repeated dilutions necessary with use of the electron capture detector.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Electric parameters ; Physico-chemical relationships ; Structure-retention study
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new equation is derived relating the retention index to the molecular polarizabilities, ionization potentials and permanent dipole moments of the stationary phase and the solute. Various implications of this equation to quantitative structure-retention relationships are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    ISSN: 1612-1112
    Keywords: Aldehydes and ketones ; 2,4-dinitrophenylhydrazine-coated silica gel ; Gas chromatography ; Column liquid chromatography ; Pollution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary After a brief review of several methods described in the literature this paper discusses air-sampling on 2,4-dinitrophenylhydrazine-coated silica gel and identification requirements for aldehydes and ketones most commonly found in industrial pollution. Quantitative analysis of formaldehyde and acetaldehyde either by GC or by HPLC techniques is established using a dynamic system producing test atmospheres and compared with the usual colorimetric determinations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 61-67 
    ISSN: 1612-1112
    Keywords: Optimization ; Carrier gas velocity ; Gas chromatography ; Influence of temperature on optimum velocity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung Die Wahl der mittleren, linearen Trägergasgeschwindigkeit bei der Analyse von Mehrkomponentengemischen unter isothermen und temperaturprogrammierten Bedingungen wird diskutiert. Es wird gezeigt, daß stets eine Trägergasgeschwindigkeit gewählt werden sollte, die mindestens gleich, besser jedoch höher ist, als die optimale Gasgeschwindigkeit für den ersten Peak, gemessen bei der Starttemperatur (Temperaturprogramm) oder bei der eingestellten Ofentemperatur (isotherme Fahrweise).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 686-692 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Micropacked columns in GC ; Microparticles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Porous silica microparticles designed for modern liquid chromatography have proven effective in gas chromatography. Columns of 35–50 cm gave plate heights as low as 3.3 particle diameters and speeds of 2400 theoretical plates per second or 500 effective theoretical plates per second. Inlet pressures up to 70 atmospheres were required using hydrogen as carrier gas. The particles as received were too retentive for fast chromatography and gave asymmetric peaks. A coating of fluorosilicone oil overcame both problems. Other coatings were less effective. Bonded phases proved less satisfactory on both counts and also gave substantially less efficient columns and greater flow resistance. Column efficiency and flow resistance were sharply dependent on physical properties of the particles. The most efficient packing was clearly spherical particles of 5–10 μm diameter with narrow size distribution, pore diamters about 50 nm, BET surface areas of 25–50 m2/g and surfaces modified with trifluoropropyl silicone. A six-component hydrocarbon sample was separated in 33 s with a resolution of 4 for the most difficult pair and in 2.6 s with a minimal resolution. Performance was limited by end effects and by available pressure so that much better performance can be expected from longer columns and higher pressures.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 752-754 
    ISSN: 1612-1112
    Keywords: Xylenol isomers ; Gas chromatography ; Polyols and polyethers as stationary phase ; Hydrogen bonding
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Xylenol isomers can be resolved on most polyols (sugars or sugar alcohols) and polyethers (polyethylene glycol or polypropylene glycol) with hydrogen-bonding interaction. They are separated on vinical polyols which have more hydroxy hydrogen than tetrol, and even on vicinal triol when its hydroxy hydrogen is acidic (stronger proton donor). The stronger is the hydrogen bonding interaction between xylenols and the liquid phase, the better is the separation of 2,4- and 2,5-xylenol, and the poorer the separation of 2,4-and 2,3-xylenol.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 19-22 
    ISSN: 1612-1112
    Keywords: Teflon columns ; Chemically modified teflon ; Gas chromatography ; Capillary columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Wall-coated open tubular columns prepared from chemically modified teflon tubing have been developed for gas chromatography. Chemical reaction of the inner walls of teflon tubing allows bonding of an adhesive layer on which a variety of stationary phaes can be coated. Test mixtures of alkanes and alcohols were used to investigate the chromatographic properties of these columns and the stability and mixing of the adhesive and stationary phae layers. the results in dicate that mixing of the layers is negligible and that the column is stable for a long period of time.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 55-66 
    ISSN: 1612-1112
    Keywords: Capillary columns, glass ; Gas chromatography ; Column preparation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Kapillar-Gas-Chromatographie ist heute das sich am stärksten entwickelnde Gebiet der Gas-Chromatographie. Es gibt viele komplexe, neue Fragestellungen in der Analytik, welche den Einsatz spezieller Kapillarsäulen erfordem. Glücklicherweise gibt es aber auch eine große Zahl von Herstellungsverfahren für Kapillarsäulen, welche — noch mehr als bei der Herstellung von gepackten Säulen — eine Anpassung an die gestellten Aufgaben ermöglichen. In diesem Artikel werden die Herstellungsverfahren für Kapillarsäulen zusammengestellt und Anregungen gegeben, wie aufgaben-orientierte Säulen erreicht werden.
    Notes: Summary Glass capillary column chromatography is the most rapidly growing part of gas chromatography. There are many complex new analytical tasks and they require special capillary columns, Fortunately there is a wide range of column preparation methods available, and they make the preparation of glass capillary columns a more varied job than that of packed columns. In this paper these methods are reviewed and suggestions are given for making task-oriented columns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 625-630 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Comparison of liquid phases ; Influence of temperature ; Retention index data
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The influence of temperature and liquid phase film thickness of open-tubular (capillary) columns on the retention index values of hydrocarbons on methylsilicone liquid phases is discussed. Data obtained on methylsilicones and squalane are compared. Retention index values of 43 hydrocarbons between 40 and 70 °C on OV-101 liquid phase are listed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 180-182 
    ISSN: 1612-1112
    Keywords: Acidic fermentation products ; Characterisation ; Gas chromatography ; Methyl esters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid and simple method for the identification of acidic fermentation products is described. Methyl esters of volatile and non-volatile acids are separated on a single chromatographic column. Retention time data for a number of acids are tabulated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 521-524 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Connectivity index ; Van der Waals' volume ; Alkanes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The relationships between retention index and Van der Waals' volume and between retention index and connectivity index have been studied for 58 different alkanes (C1−C9) on squalane. The correlation coefficient for the former is higher than for the latter. From these equations a linear relationship between Van der Waals' volume and connectivity index is obtained which indicates that the two parameters are equivalent. A simple method for calculating the Van der Waals' volume of alkanes is proposed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 98-102 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Rectangular channel ; Efficiency ; Capacity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatographic experiments have been performed in a truly rectangular channel with a 60∶1 cross-sectional aspect ratio, constructed according to the field-flow fractionation technology. It is shown that the peak broadening is controlled by the thickness of the channel while the maximum load is determined by the largest cross-sectional dimension. However, even with its elongated configuration, the side walls contribute significantly to the band broadening of solutes with a high diffusivity. Good agreement is found between the experimental plate height data and the recent theoretical calculations of Golay [13] taking into account the side-wall effect.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 241-243 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Detectors ; Flame ionization detector ; History of chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary On the occasion of the 25-year anniversary of its invention, this article summarizes the events which led to the development of the flame ionization detector.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Average molecular polarizability ; Retention index ; Polycyclic aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The Kováts retention indices of 10 polycyclic aromatic hydrocarbons were determined on SE-30, OV-101, SE-52, OV-7 and OV-17 stationary phases. A significant correlation has been found between the retention indices and the average molecular polarizabilities of the analyzed substances. Equations were derived for the direct determination of the average molecular polarizabilities from the retention index values. The influence of the temperature on this relationship is also indicated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 418-420 
    ISSN: 1612-1112
    Keywords: Separation of metal chelates ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A very good separation of the acetylacetonate of AL-(III), Cr(III) and Co(III) has been obtained by gas chromatography, on a column containing OV-17 silicone oil as the stationary phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Esterification in aqueous solution ; n-Butyl esters of C2−C16 dicarboxylic acids ; Dicarboxylic acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary C2−C16 dicarboxylic acids were esterified in aqueous solution in the presence of sulfuric acid. Esterification in water/n-butanol mixtures with mole ratios between 0.02 and 2.53 can be utilized for the quantitative determination of the dicarboxylic acids by gas chromatography. The presence of water does not interfere at water/n-butanol mole ratios below 0.27. For mole ratios above 0.27 anhydrous sodium sulfate has been used for binding the water. The mole ratio range was 0.25–0.75 for anhydrous sodium sulfate/water, and 0.32–1.3 for sulfuric acid/anhydrous sodium sulfate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 202-204 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Polysiloxane stationary phases ; Heat of adsorption ; Heat of solution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The changes in the heat of solution of polar compounds and xylene isomers in methylsilicone fluid OV-101 deposited on Chromosorb W AW DMCS were studied. It was shown that the heat of solution increases with an increase of the percentage loading of the OV-101 up to 10%. Solution and adsorption thermodynamic characteristics of the studied system are briefly discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    ISSN: 1432-0878
    Keywords: Preputial glands ; Nude mice ; Ultrastructure ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The preputial glands of male nude (nu/nu) mice were analyzed by a combination of electron microscopy and gas chromatography to determine whether or not they are affected, like developing hairs and nails, by the nu/nu genotype. Results of the analyses revealed no differences between the glands of nude and normal male mice in either their ultrastructural characteristics or lipid secretory products.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 89-90 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Histamine TMS derivatives, complete separation, 2 minutes ; NPD used for quantitation down to 20 pg ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Complete separation of the TMS derivatives of histamine, 1-methyl histamine and 3-methyl histamine was achieved in two minutes in a 7 m × 0.25 mm column coated with SP 2250. Using NPD, histamine was detectable at levels as low as 20 pg. This offers a rapid, sensitive procedure with potential for clinical diagnosis and food analysis.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 301-302 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Polychlorinated biphenyls ; Liquid crystal phase ; Choice of stationary phases for analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 351-352 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Injector ; Concentrator ; Electrically heated inlet ; Capillary columns ; Vapor sampler ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 11-16 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; SCOT column ; Coating, liquid phase ; Single-step coating ; Phenols ; Phenolic acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A single-step coating method for the preparation of glass capillary SCOT columns is described. It is reproducible and less time-consuming than the well-known two-step coating procedures. Other methods attempted are discussed briefly. Both the flame ionization and electron capture detectors could be used in conjunction with temperature programming. The separations achieved with an “activity mixture”, phenols and phenolic acids, illustrate the resolution obtained. The columns are suitable for quantitative determinations and a comparison is made with a conventional packed column.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 38-39 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary column ; Activity ; Hydroxylated surfaces ; Dehydroxylated surfaces ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 86-86 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Recycle chromatography ; Multiple-pass chromatography ; Thermal focussing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 146-146 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Cold trap heating ; Thermal focussing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 25-27 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Instrumental modification to multidimensional separation ; Application with packed columns on complex sample composition ; Indene to pyrene range in coal tar ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 91-91 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Static coating technique details ; End-sealing without failure, under ethanol ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 195-195 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Columns, packed ; High resolution ; Packing apparatus ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 411-412 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Chemical bonding - cross-linking ; Apolar columns ; Preparation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 298-298 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Closing technique for static coating ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 302-302 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; Fitting silica capillary columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 523-524 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Split injection ; Injection time influence ; PAH ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 533-534 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; End-sealing method for static coating ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 303-305 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Surface modification ; Sulfur dioxide treatment ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 473-474 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Complex wax ester mixtures ; Resolution of components by total carbon number and by degree of unsaturation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A glass capillary GC method providing high resolution analysis of complex wax ester mixtures is described. The two key parameters needed for evaluating a wax ester mixture for industrial utility - the total carbon chain length and the number of carbon-carbon double bonds present in each component - are simply and rapidly obtained by this method.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 405-410 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Determination of adsorption ; Irreversible adsorption on glass columns made visible ; Fluorescent compound PMBF2 ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: PMBF2, a pyrromethene pigment, can be used in gas chromatography. Because of its fluorescence, adsorption sites on glass columns and connections can be traced in situ. The compound can be employed to check the inertness of glass surfaces after deactivation procedures. Some applications are described.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; High temperature silylation ; C2-C6 fatty acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 525-526 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Static coating ; Filling the column by pressure, not by vacuum ; Device for filling by pressure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 521-522 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Computerized gas chromatography/mass spectrometry ; Capillary, OV-73 fused silica ; On-column injection ; Alkyl porphyrins ; Bis(trimethylsiloxy)silicon(IV) derivatives ; Fused silica as a GC/MS interface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Electron capture detection ; Analysis of carboxylic acids and phenols in water ; Extractive alkylation ; Pentafluorobenzyl derivatives ; Steam condensate and domestic sewage effluent ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is presented for the simultaneous determination of a wide range of carboxylic acids and phenols in water. Extractive alkylation is used with the tetrabutylammonium ion as counter ion and pentafluorobenzylbromide as alkylating agent. Extracts are analyzed by glass capillary gas chromatography and electron capture detection. Using one ml of water sample, the detection limit lies in the range of 1-10 μg/l. Application has been made to the analysis of steam condensate and domestic sewage effluent.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 627-633 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Vaporizing injectors ; Dicrimination of high-boiling components ; Elution out of the syringe needle ; “Hot needle”, “solvent flush” techniques ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Unequal elution of sample components of different volatility out of the syringe needle is one of the major causes for discrimination occuring during the injection, i.e. the phenomena which results in peak areas for the high boiling compounds which are too small compared with the volatiles. This problem, associated with all vaporizing injectors that are used with syringes, can be minimized by careful choice of the needle handling technique. Various methods are compared experimentally. The “solvent flush” method is discussed in detail and demonstrated to be ineffective for reducing losses in the syringe needle. The “hot needle” technique, where the empty needle is preheated in the injector before pushing the plunger, was found to be superior or equal to an improved “solvent flush” method (which included preheating the needle and omitting the air plug between sample and flushing solvent. Generally it was found that the discrimination due to the syringe needle was reduced for larger sample volumes, although no further changes were noticed when these exceeded 2.5 to 3μl.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 641-642 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Polar open-tubular columns ; Silar 10CP, 0.2% ; Recoating of capillary columns to restore efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 421-422 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Unstable flavor compound ; Comparison of fused silica, glass, and metal columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 49-53 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Glass capillary ; Routine analysis of C1-C6 carboxylic acids ; Animal wastes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The C1 -C6 fatty acids present in various types of heterogeneous animal wastes were isolated by steam distillation and determined as benzyl esters by high resolution gas chromatography. Glass capillary columns, deactivated with barium carbonate and coated with UCON HB 5100, allowed the analysis of benzyl formate, acetate, propionate, isobutyrate, butyrate, isovalerate, valerate, and caproate in less than 20 minutes. Recovery tests, performed on more than 50 different samples, indicated a benzylation yield and an overall efficiency higher than 99%, with a standard deviation of 2.6% (C5) to 6.0% (C1). The absolute detection limit ranged from 0.3 picomole (caproic acid) to 1.0 picomole (formic acid).
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 495-499 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, fused silica ; Mass spectrometry ; Interface, direct coupling ; On-column injection ; Aflatoxin B1 ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A novel fused silica capillary GC/MS direct coupling is described which ensures quantitative transfer of sample from the point of injection to the ion source of a mass spectrometer without contacting any surfaces other than the column wall. This device permits GC analysis of highly labile substances. Aflatoxin B1, previously considered unassayable by GC, can now be determined by GC/MS.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 164-168 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Simultaneous detection with effluent splitter ; Element-specific detection ; Petroleum residues ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two glass capillary gas chromatographic systems were equipped with inert effluent splitters which allowed simultaneous data acquisition using nonspecific and element-specific detectors. Simultaneous detection was achieved using the nonspecific flame ionization detector (FID) and the Hall® electrolytic conductivity detector (HECD) operated in either the sulfur-or the nitrogen-specific mode. Typical application of the simultaneous detection system as applied to analysis of petroleum residues is briefly described. The Hall electrolytic conductivity detector can be made element specific for halogen-, sulfur-, or nitrogen-containing compounds. Simultaneous detection enhances the information yield from a single sample injection and proves to be a powerful complementary technique when used with computerized gas chromatography/mass spectrometry.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 169-172 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Residue analysis ; Pirimiphos-methyl ; Malathion ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A gas chromatographic method developed for the simultaneous determination of residues of pirimiphos-methyl (O-[2-(dimethyl-amino)-6-methyl-4-pyrimidinyl] O,O-dimethyl phosphorothioate) and malathion (diethyl mercaptosuccinate S-ester with O,O-dimethyl phosphorodithioate), in whole peanuts, peanut hulls, peanut meats, and peanut oil gives good recoveries and has a limit of detection for pirimiphos-methyl and malathion of 0.04 ppm. Quantitative analysis for the two insecticides with electronic integration was reliable to 0.1 ppm.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 295-296 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 257-259 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Dihydro dimethyl ethers of vitamin K1 ; Separtion of diastereomers ; Characterization of source of vitamin K1 samples ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for the gas-chromatographic determination of the diastereomers of vitamin K1 (phylloquinone) in the form of their dihydro dimethyl ethers. The reported method of derivatization and chromatographic analysis in conjunction with optical rotation measurements are useful approaches for characterization of vitamin K1 samples with respect to their origin.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 333-336 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Rapid analysis ; On-line analysis ; Low molecular weight hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Rapid analysis is important for on-line chromatography. Gaseous or vaporized samples have been injected via heated gas sampling valves of less than 500 μl dead volume. The critical sampling and split problems could be solved by temperature programming. The general analysis described could be successfully used inter alia in scouting reactions.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Dynamic headspace analysis ; Solid waste ; Fused silica capillary columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A dynamic headspace stripping technique for the extraction of volatile organic compounds has been applied to a variety of solid and semisolid waste materials. A simple glass apparatus accommodates a wide range of sample sizes and allows for the volatiles to be stripped at elevated temperatures. Concentration on Tenax, followed by thermal desorption and analysis by fused silica capillary gas chromatography provides detailed information on the volatile content of waste samples of widely differing matrix composition.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 55-56 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Non-uniformity of distribution of stationary phase confirmed ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...