ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electron microscopy  (538)
  • Immunocytochemistry  (218)
  • 42.55  (171)
  • Bone  (145)
  • Springer  (1,060)
  • Cambridge University Press
  • Frontiers Media
  • 2020-2022
  • 1980-1984  (488)
  • 1975-1979  (572)
Collection
Keywords
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 261 (1983), S. 373-374 
    ISSN: 1435-1536
    Keywords: Electron microscopy ; short-time staining ; nodular structure ; crystallization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 260 (1982), S. 564-569 
    ISSN: 1435-1536
    Keywords: lin. Polyethylene ; Single crystals ; Heat of Fusion ; DSC ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Recently published results for solution crystallized PE single crystals have shown, that the experimental heat of fusionΔH * is higher, if the solvent is exchanged to silicon oil (oil suspension samples) as compared with dried mats. This has been interpreted by the collapse of the original hollow pyramids during drying, inducing lateral defects within the lamellae. The present investigation does not confirm this unexpected result.ΔH * of dried mats (T c 66 to 91 °C) and of the corresponding oil suspension samples agree within the rather small limits of experimental error. The crystallinities as derived fromΔH *, density or WAXS are in excellent agreement. SEM micrographs of cold fractured dried mats show their spongy macromorphology, but TEM micrographs of stained ultra-thin sections reveal the lamellar morphology of the walls, consisting of curved lamellae and stacked hollow pyramides. If a dried mat is sintered at room temperature, a dense transparent film is obtained with a rather regular stacked morphology of large flat lamellae.ΔH * of these films agrees with that of the original mat.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 33 (1984), S. 115-131 
    ISSN: 1432-0649
    Keywords: 02.20 ; 42.55 ; 42.60D
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract This study puts forward the concept of helical distributed feedback (DFB) lasers. The basic features of this new type of laser are derived by group theoretical considerations on cylindrical, circular linear periodic, and helical waveguide and laser structures. It is demonstrated that not only linear periodic structures but also helical structures show Bragg and DFB effects. Microwave and far-infrared experiments on passive helical metal waveguides reveal Bragg resonances in transmission. These results initiated the first experimental realization of a helical DFB gas laser, i.e. an optically pumped 496μm CH3F laser with a helical metal waveguide of a pitch close to 250μm. This helical DFB laser shows higher-mode selectivity than the corresponding linear DFB laser. Finally, we show that the concept of helical DFB also applies to dye lasers with internal DFB incorporated by a mixture of the dye with a cholesteric liquid crystal.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 34 (1984), S. 17-21 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Twenty-four new optically pumped submillimetre laser lines have been observed when CH3OH is excited using a13C18O2 pump laser. Four of these lines have been assigned to transitions involving the CO stretching band. In addition to these lines, a further six new lines have been observed when pumping with12C18O2 and13C16O2 lasers. One of these lines has been assigned to a transition involving the CO stretching band. The observation of infrared-infrared double resonance signals in CH3OH has allowed the prediction of a further six laser lines which should be excited using a13C18O2 pump laser.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 34 (1984), S. 221-228 
    ISSN: 1432-0649
    Keywords: 42.55 ; 41
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The conditions under which a cooperative emission from different friges occurs in the scattering between a relativistic electron beam and two interfering laser beams are discussed. In particular, the conditions to have an electron grating are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 35 (1984), S. 77-82 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.65
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The coexistence of bistability and repetitive passive Q-switching of a CO2 laser with a gaseous saturable absorber has been investigated experimentally. With CH3F as the saturable absorber bistability has been observed simultaneously with passive Q-switching, whereas with CH3OH either one of these phenomena can only exist, as demonstrated for the first time. The measured features of both systems can be explained qualitatively by rate-equation theory.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 35 (1984), S. 127-129 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Strong submillimetre laser action has been obtained on five lines of a new laser gas, formaldoxime. Several new emission lines have also been produced by isotopic CO2 laser pumping of14NH3 and15NH3. One of these lines at 102.9 μm is a rotation-inversion transition in the 2v 2 state, and is the first example of cw laser action in such a highly excited state.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-0649
    Keywords: 33 ; 82.50 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We measured the photoionization cross-sections of anthracene, 1,2-benzanthracene,p-terphenyl, and 2,5-diphenylfuran molecules excited to the singlet and triplet electronic states intermediate in the stepwise two-photon ionization process at 266 nm (all compounds) and at 355, 391 and 417 nm (anthracene).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 28 (1982), S. 373-381 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.80 ; 52
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We investigated noise and fluctuations of the output power of cataphoretic HeSe+ lasers in positive column plasma. Direct coupling of laser output power noise and fluctuations of the local population inversion was found. An investigation of the positive column plasma showed moving striations being responsible for the gain fluctuations. Whereas the local plasma properties are dominated by high frequency striations in the 100 kHz range, integrated quantities such as laser gain per pass are most strongly influenced by low-frequency waves with a continuous noise spectrum below 200 kHz. External modulation of the discharge voltage or current at a frequency near thehf striations reduces laser noise and increases laser output power.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-0649
    Keywords: 32 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Optical absorption,S 1 lifetime, and photostability are investigated for a series of heptamethine ir dyes and related to chemical structure. The high photostability of several dyes and the large range ofS 1 lifetimes make these dyes very interesting for ir dye lasers and for ir mode-locked laser systems.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 29 (1982), S. 13-14 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Intense far-infrared laser action is reported for carbonyl fluoride and vinyl fluoride. Eleven new lines with wavelengths between 339 μm≦λ≦538 μm were obtained by optically pumping carbonyl fluoride with numerous lines of the 10.4 μm band of a cw CO2 laser. Twenty-three lines with wavelengths in the range 172 μm≦λ≦783 μm were detected when pumping the recently discovered efficient FIR laser molecule vinyl fluoride. In addition, three very weak new lines were found using 1.1-difluoroethylen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 29 (1982), S. 263-267 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.65 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The duration, shape, and background intensity level of pulses of a passively modelocked Nd-glass laser are determined by noncollinear phase-matched four-photon frequency mixing of time-separated fundamental and second-harmonic pulses in a KI crystal. The pulse shape is found to be slightly asymmetric with slower trailing than rising parts. The background intensity level before and behind the main pulse is about 5¢10−6 the peak pulse intensity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 30 (1983), S. 1-4 
    ISSN: 1432-0649
    Keywords: 33 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Twenty FIR laser lines with wavelengths between 146 and 2000 μm have been observed from deuterated formyl fluoride (DCOF) optically pumped with isotopic CO2 lasers. Tunable diode laser measurements on thev 4 band of DCOF were combined with earlier high precision spectroscopic data on thev 3 andv 4 bands, and enabled identification of the transitions responsible for 9 of the new FIR lines.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 30 (1983), S. 135-142 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract An analysis of cw synchronously pumped dye lasers is presented. Under the assumption that the cavity (tuning element) bandwidth is much wider than the bandwidth of the transform limited pulses generated, the pulse forming dynamics is rigorously treated. It is shown that for a finite mismatch between the lengths of the dye and the pump lasers, a steady-state pulse develops in the dye laser cavity with a conserved pulseshape. The characteristics (energy, shape, peak power, duration) of these pulses of ultimate width are quantitatively determined as a function of cavity mismatch. An analytical solution for the pulse envelope is determined, which yieldsI(t)∝Sech2(t/t p ) to a good approximation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 32 (1983), S. 75-78 
    ISSN: 1432-0649
    Keywords: 33 ; 34 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Multiphoton absorption (MPA) of the CO2 laser 9 μmR(30) line (pulse width 60 ns, FWHM) by NH3 and NH3/N2 mixtures was studied as a function of gas composition, pressure and laser fluence (Φ). MPA occurs for Φ smaller than those that have been used for optically pumped NH3/N2 lasers; consequently a simple two-level absorption model will not adequately describe laser action in these systems. The photon energy deposited in NH3/N2 mixtures can be calculated from the MPA cross-section and the fluence dependence of the illumination geometry. An examination of the efficiency of conversion of this absorbed energy to the reported radiant energy of optically pumped NH3/N2 lasers shows an optimum value which depends on pressure, and gas composition.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 32 (1983), S. 105-111 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The effects of H2, He, and N2 buffer gases on the efficiency of the cw 12.08 μm NH3 Raman laser are studied experimentally. The laser output power is increased by nearly 60% with the addition of H2 or He, which we essentially attribute to the high thermal conductivity of these buffer gases. In the optimum conditions (NH3/H2:1/1 mixture with 0.35 Torr partial pressure of NH3) 3.3 W output power at 12.08 μm is obtained which corresponds to 11% power conversion efficiency.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 32 (1983), S. 127-135 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A cw uv copper hollow cathode laser is described, which could be operated for a longer time duration with an output power of 7 mW in the 260 nm region. A double-cathode configuration with a protection for the mirrors from metal-vapour deposition is presented. Characteristics of the laser output power, the spontaneous emission, and the ion densities in the negative glow were measured as depending on the discharge current, the neon gas pressure, and the size of the cathode slit. The observed saturation of the laser output power at high discharge current (1 A/cm2) and the optimum slot size are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 33 (1984), S. 23-27 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract For the first time stable cw output of a FIR-CO2 hybrid laser has been achieved at wavelengths shorter than 300 μm. Due to the saturable absorber characteristic of the FIR laser gas, cw or pulsed emission is observed on both, the CO2 and the FIR laser output, depending on the operating conditions. Results are reported on different resonant lines in CH3OH and the 67 μm Raman line in NH3. The good efficiency of this laser is also demonstrated by the excitation of two new emission lines in CH3OH, namely 49 and 56 μm, pumped by 9R(22) and 9R(24), respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 34 (1984), S. 83-86 
    ISSN: 1432-0649
    Keywords: 33.50 ; 34.50 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract An XeF pumped vapor phase POPOP dye laser with a pulse duration of 300 ns was obtained when trans-stilbene was used as triplet quencher. An energy conversion efficiency of 7,5% with a peak power efficiency of 12% was measured.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 34 (1984), S. 175-177 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract 47 new cw far-infrared laser lines with wavelenths between 453 and 2356 μm have been obtained by optically pumping vinyl bromide (C2H3Br) by a CO2 laser. A significant portion of these lines has wavelengths longer than 750 μm.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 35 (1984), S. 163-166 
    ISSN: 1432-0649
    Keywords: 42.50 ; 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We present an analytical expression for the small-signal gain of a Free Electron Laser (FEL) in the presence of a Gaussian mode. To describe the electron beam evolution we use the one-dimensional (1-d) Vlasov equation. Our perturbation result, valid for small values of the parameterq (length of the undulatorL divided by the Rayleigh rangeZ R), can be extrapolated to values ofq≈4÷5.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 26 (1981), S. 161-167 
    ISSN: 1432-0649
    Keywords: 52.80 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A new magnetic discharge stabilization technique for coaxial laser systems is described. The approach utilizes crosses electric and magnetic fields to create and maintain a large and rapidly rotating plasma volume which does not experience glow-to-arc transitions. Very high cw specific discharge power loadings have been achieved even without the benefit of external gas cooling or circulation. Performance is insensitive to gas composition and pressure such that high power coaxial discharges have been run in CO2 laser gas mixtures up to several hundred torr. Stable cw discharges have also been obtained in mixtures containing several torr of SF6. The technique appears to be readily scalable to give very large excited volumes in systems with comparatively small overall physical dimensions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 32 (1983), S. 83-84 
    ISSN: 1432-0649
    Keywords: 42.55 ; 33.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A population inversion between the 62 P 3/2 and 62 P 1/2 state of thallium has been achieved for the first time by incoherent photodissociation of TII. This is accomplished by using wall-ablating flashlamps of short risetime and appropriate light filtering. The inversion lasts about 4 μs and is terminated by quenching collisions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 32 (1983), S. 193-198 
    ISSN: 1432-0649
    Keywords: 42.55 ; 33 ; 82.50
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The vibrational relaxation time constant for theB v=0 vibrational level of XeCl* has been investigated by observing the coupling between theB v=1 andB v=0 vibrational levels under saturated lasing conditions. Based on this observation, estimates of the expected extraction efficiency from theB-state have been made.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 33 (1984), S. 9-16 
    ISSN: 1432-0649
    Keywords: 42.60 ; 42.20 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We derive the most general equations of motion for the electrons and the electromagnetic field in a free-electron laser including the effects of diffraction and pulse propagation. The field evolution is expressed in terms of the amplitudes and phases of a complete set of transverse modes. The analytic solution is given in the small-signal regime, where the theory is shown to be in excellent agreement with a recent experiment at Orsay.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Experiments on pressure dependence of a CF4 laser have been carried out to elucidate dynamic characteristics of CF4 molecules pumped by CO2 lasers. The results are followed by a model calculation which characterizes collisional quenching of the energy levels related to the stimulated emission. The enhancement of the laser output induced by buffer-gas addition, which was found under specific conditions, is discussed in relation to the competition between laser and superfluorescent emissions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 26 (1981), S. 73-76 
    ISSN: 1432-0649
    Keywords: 07 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A liquid nitrogen cooled cw CO-Laser is described, with which laser action up to 8.18 μm (v=36→35) has been achieved.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 26 (1981), S. 141-146 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We have designed and tested a pulsed single-mode dye laser for spectroscopy experiments. The dye laser is pumped by a 6 kHz copper vapor laser to produce up to 230 mW average power at over 5% efficiency in a nearly diffraction limited beam. The dye laser pulse closely resembles the 30 ns pump pulse. Using an electronic servo loop, the 60 MHz wide line can be scanned, without mode hopping, through the 16 GHz permitted by the travel on the piezo driven mirror mount.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 30 (1983), S. 29-33 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract This report describes an experimental examination of the output characteristics of the continuous-wave (cw) carbon monoxide flame chemical laser (FCL) of the CS2/O2/N2O type in case of small CS2/O2 reactants ratios (tipically CS2/O2≦1/10). A linear burner which gives a homogeneous and stable flame was used during the experimental study. The measurements of temperature distribution in CS2/O2 as well as CS2/O2/N2O flames show maximum temperatures of 1040 and 890 K, respectively. The addition of nitrous oxide (N2O) leads to dramatically enhanced output laser power caused primarily by V−V transfer processes. A chemical efficiency, based on the reaction O+CS→CO*+S, of 3% was achieved. The spectral composition of the CO FCL of the CS2/O2/N2O type shows lasing in the region from 5.130 to 5.586 μm. Experimental results were obtained with a nondispersive optical cavity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 31 (1983), S. 5-8 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Short FIR laser pulses of high repetition rate are obtained by pumping NH3 with the pulses of a passively Q-switched IR laser. The two cascade laser transitions observed show coupled relaxation oscillations. The pulse shapes and delay times are qualitatively in agreement with a four-level rate-equation model.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    ISSN: 1432-0649
    Keywords: 82.65 ; 68 ; 36.40 ; 78 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    ISSN: 1432-0649
    Keywords: 85.60 ; 42.80 ; 42.55 ; 33
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 33 (1984), S. 235-238 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract An intensive generation of radiation from a discharge-pumped atomic-fluorine gas laser is reported. A peak power exceeding 330 kW and a total energy of more than 2 mJ is obtained for a number of lines in the red, using a NF3∶He (1∶100) gas mixture at total pressure of 500 Torr. The circuitry optimization is described and the conditions for effective operation of the atomic-fluorine laser are discussed. The temporal and the spectral characteristics of the laser emission are also presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 29 (1982), S. 157-158 
    ISSN: 1432-0649
    Keywords: 42.60 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    ISSN: 1432-0649
    Keywords: 42.60 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Conclusion We have demonstrated the existence of an anomalous polarization coupling mechanism present in the injection locked TEA CO2 laser. As a direct consequence of this work, a new injection technique has been formulated which permits efficient injection coupling and maximises energy extraction whilst eliminating the detrimental optical feedback effects to which other injection locking systems are prone.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 35 (1984), S. 71-75 
    ISSN: 1432-0649
    Keywords: 42.60 ; 42.55 ; 42.72
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A simple model of the energy transfer between a booster dye and the active dye in a flashlamp pumped planar waveguide dye laser is described. Analytical results are compared with experiments for several dyes in the 600–650 nm region. A twofold increase of laser output was found at a wavelength (630 nm) which is of particular interest for several applications.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 33 (1984), S. 187-193 
    ISSN: 1432-0649
    Keywords: 42.50 ; 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract It is shown by numerical analysis based on Lamb's equations of motion, that standing-wave lasers with purely homogeneously broadened emission lines exhibit regular multimode oscillations. Specifically, modes lying far from the line centre are quenched due to mode competition, and the amplitudes of the oscillating modes approach steady-state values. The stabilization of the amplitudes is normally accompanied, or followed, by an evolution of the phases towards a phase-locked regime, where the relative phasesψ n = 2φ n −φ n + 1 −φ n − 1 [φ n phase in then th mode, defined by (6)] attain either the value 0 or ± π. The build-up times for the relative phases are found to vary over a wide range.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 35 (1984), S. 11-15 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The temporal development of the small-signal gain on the Cl2(D′−A′) transition at 258 nm has been investigated by means of an amplified spontaneous emission (ASE) technique. For electron beam pumped He/Cl2 mixtures, the gain appears only at the end of the pumping pulse, whereas for He/Cl2/CCl4 mixtures the temporal gain profile coincides with the fluorescence pulse, and the maximum gain coefficient increases by about a factor of two. The observed effects are due to the mixing of both halogen donors and can be explained by considering the quenching of theD′-state by electrons.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 27 (1982), S. 27-37 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The circulation of a synchronously mode locked dye laser pulse in a linear cavity configuration containing a dye cell as an active medium and a bandwidth-limiting element is treated. The condition that the pulse shape reproduces after each cavity round-trip provides a nonlinear integro-differential equation for the steady-state pulse shape. For the solution of this equation an approximate method, not limited to small pulse energies, is given and the pulse duration, intensity, energy, asymmetry of the pulse shape, stable regions and other interesting parameters are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 27 (1982), S. 49-55 
    ISSN: 1432-0649
    Keywords: 42.55 ; 34 ; 33
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Lasing from e-beam pumped He/Cl2 mixtures at 258 nm was investigated in a longitudinal pumping geometry. Time dependence, output powers and energies as well as the spectral composition of the laser pulses were determined for different experimental conditions. Optical gain was observed for eight transitions around 258 nm. The fine structure results from isotopic splitting and contributions from different vibrational states. No bottle-necking occurs. However, saturation and absorption by excited states limited the total output power to 6MW and the output energies to 200 mJ. A simple kinetic model is proposed that reproduces the larger number of experimental data quite sufficiently.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 26 (1981), S. 31-32 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A 4 J XeCl (308 nm) laser has been used to produce ∼ 1 J of dye laser output from selected dyes whose lasing wavelengths sample the spectral range from 330 to 600 nm.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 26 (1981), S. 33-36 
    ISSN: 1432-0649
    Keywords: 42.55 ; 33 ; 34
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A far-infrared (FIR) NH3 laser was resonantly pumped with a line-tunable infrared (IR) NH3 laser. The number of the observed FIR laser lines amounted to 33. Most of them belonged toaR(J,K) rotation-inversion transition in (0, 1, 0, 0) vibrational state. The line tunability of sealed-off FIR NH3 laser was almost achieved in 90, 115, 150, and 220 μm wavelength regions by the selective line tuning of the pumping IR NH3 laser.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 29 (1982), S. 195-200 
    ISSN: 1432-0649
    Keywords: 42.55 ; 35
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Laser emission at different wavelengths in the range of 903–914 nm and around 2.5 μm has been observed upon excitation of Na2 by uv radiation from an excimer laser at 351 nm and an excimer pumped dye laser in this wavelength range. The emission is attributed to a cascade emission $$C^1 \Pi _u \to 2^1 \sum _g^ + $$ followed by $$2^1 \sum _g^ + \to A^1 \sum _u^ + $$ . In addition, coupled with the laser emission around 910 nm, broad-band fluorescence peaking around 855.5 nm is observed which, eventually, may be the first observation of the $$b^3 \sum _g^ + \to x^3 \sum _u^ + $$ bound-free transition in Na2.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 27 (1982), S. 105-113 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The circulation of an ultrashort light pulse in a continuously pumped modelocked dye laser with a linear cavity configuration containing the active dye, the saturable absorber and a bandwidth-limiting elements is treated. The steady-state condition that the pulse shape reproduces after each cavity round-trip leads to a nonlinear integro-differential equation for this pulse shape. An approximate method for the solution of this equation not limited to the case of low laser gain and small pulse energies is given. The stable single pulse region and characteristic pulse parameters, as energy, duration, intensity and asymmetry, are considered in dependence on the laser parameters.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    ISSN: 1432-0649
    Keywords: 42.55 ; 41
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The relativistic motion of a charged particle in an electromagnetic field depending only on one coordinate is shown to be exactly equivalent to the unidimensional motion of a particle having a time and space-varying mass. By means of the averaged Lagrangian method an approximate solution is obtained for the relativistic electron motion in two oppositely moving waves of any polarization, one of them being weaker than the other one, thus generalizing the results previously obtained for circular polarization. A comparison with numerical calculations shows a good agreement. A pendulum-like motion in an effective periodic potential is shown to exist not only for two waves of the same frequency, but more generally when the frequency of the weaker wave is an odd harmonic of the frequency of the stronger one.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 34 (1984), S. 191-192 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A pulsed xenon ion laser has been used to pump a rhodamine 6G dye laser utilizing a ring resonator. The dye laser has been passively mode-locked; a pulsewidth of 0.5 ps and a 50 kW peak power have been obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    ISSN: 1432-0649
    Keywords: 42.80 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 26 (1981), S. 49-56 
    ISSN: 1432-0649
    Keywords: 42.55 ; 52.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The cw output power of the uv CuII laser has been optimized with respect to the hollow cathode geometry, the discharge current, the fill gas pressure and the resonator mirror parameters. A maximum laser output power of 900 mW for multiline operation at 248.6, 259.1, 260.0, and 270.3 nm was achieved with 100 A discharge current, 260 V voltage and 16 mbar fillgas pressure, when a hollow cathode of 1.2 m length and 2×6 mm2 cross section was employed. The single-pass pain gl has been estimated to 7%. A hollow cathode cross section of 1.5×4.5 mm2 is suggested as an optimum geometry. In addition, some investigations on the mechanism of the laser power decay in Ne−Cu-discharges are presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 26 (1981), S. 239-242 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A mode-locked Nd-glass laser oscillator with intra-cavity pulse selection by a Pockels cell shutter is described. A regenerative amplifier system with a saturable absorber is used to shorten the selected light pulses from the master oscillator. Pulses were shortened from 8 ps to 1 ps.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 29 (1982), S. 101-109 
    ISSN: 1432-0649
    Keywords: 42.50 ; 42.55 ; 52.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We study the electron phase-space evolution and gain in free electron lasers whose short-wavelength radiation has Gaussian spherial wavefronts. Several free electron laser designs are considered: the undulator, the tapered wavelength undulator, and the optical klystron. We find that the gain spectrum is no longer proportional to the slope of the forward spontaneous emission spectrum, and we determine the design of the Gaussian mode which maximizes the energy extraction from the electron beam.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.65
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We report detailed experimental data on the passive Q-switching operation in a CO2 laser with CH3I saturable absorber, and on the transient behaviour in the near-Q-switching situation. Under suitable operating conditions, we found bistability in the output power. In some cases, we observed the simultaneous presence of bistability and passive Q-switching. The theoretical part of the paper starts from the four-level model of laser with saturable absorber, as formulated by other authors. By adiabatically eliminating the variables of the resonant levels, we reduce the problem to a set of three differential equations, from which we derive explicit analytical conditions for the rise of passive Q-switching. These conditions turn out to be in good qualitative and partially quantitative agreement with our experimental findings as well as with other experimental data previously obtained by other authors. Finally we classify the possible combinations of passive Q-switching and bistability that one can find in this type of experiments.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 30 (1983), S. 109-116 
    ISSN: 1432-0649
    Keywords: 33 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The stability of polymethine dyes under XeCl laser excitation has been investigated. (For these dyes emitting in the ir the difference between absorbed and emitted photoenergy is 2 eV.) The stability was measured in an amplifier device operating in the saturated regime. While the influence on dye concentration is negligible, the fluence dependence shows the importance of two photon absorptions. A meausure for the stability is the number of photons which can be emitted per dye molecule before the dye solution has degraded to 50% of the initial value. This value is in the range of 150–280. The stability is clearly related to the formation of photoproducts absorbing at the pump and the laser wavelength. A model starting from the change in the dye solution absorption spectra is in very good agreement with the observed energy decays.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 35 (1984), S. 227-231 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The feasibility of using the electrically excited XeF(C»A) excimer medium as an efficient wideband amplifier in the blue-green region of the spectrum has been investigated. Calculations show that for an intense blue-green optical flux input the amplification characteristics of XeF(C»A) improve, as a result of both bleaching of the pump induced absorbers and by additional production of XeF(C) level population. The removal of one of the major absorbing species, Xe** in the XeF (C»A) laser mixture by means of a pulsed ruby laser probe beam has been demonstrated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 26 (1981), S. 197-202 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A theoretical treatment of the influence of a saturable absorber in close contact with a highly reflecting mirror on a light pulse is given. The shaping of a Gaussian pulse during a single passage through such an absorber is calculated for various absorber lengths. The influence of absorber position and length on the pulse parameters and the stability of a continuously pumped dye laser are investigated. The shortest pulses and the most favourable operation conditions of the laser are to be expected in the case of a short contacted saturable absorber.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 27 (1982), S. 123-128 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract This paper reports results of an experimental study of a cw 118.6 μm H2O waveguide laser. The laser cavity is a 3 cm inner diameter, 3.2 m long Pyrex tube, with plane reflectors against its ends, one of them being a copper mesh coupler. The active medium is a H2O:H2 gas mixture. Successive optimizations lead to a reliable output power of 50 mW, for the EH11 mode. The power density is the highest ever reported, and the stability is such that the power drifts by less than 2% per hour. This laser is competitive with the optically pumped 118.8 μm CH3OH laser.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 27 (1982), S. 201-205 
    ISSN: 1432-0649
    Keywords: 42.10 ; 42.55 ; 78.20
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The transmission of ultrashort pulses from a mode-locked Nd: glass laser in germanium of various thicknesses (3 to 8 μm) has been measured as a function of incident irradiance. Transmission is seen to increase with irradiance level in all samples. The degree of enhancement is greater for the thcker samples. At high excitation levels, thinner samples show a peaking of transmission, which does not occur in a thick sample. Taking the sample as composed of thin elements, the parameters characterizing the photoexcited electron-hole plasma have been found by assuming homogeneous excitation within each element. Theoretical curves thus obtained give good quantitative account of the experimental results. Peaking of transmission is seen to due to a balance between absorption enhancement in the front portion of the sample and absorption reduction in the back.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 28 (1982), S. 55-62 
    ISSN: 1432-0649
    Keywords: 33 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Infrared (ir) emissions from a TEA-CO2-laser-pumped NH3 laser are reported. Superfluorescent emissions and selective single-line oscillations have been obtained in the range from 11 to 13 μm. The results make possible the design of a NH3 Stark cell allowing a 1 GHz shift of the 10.78 μm NH3 emission line.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 239-242 
    ISSN: 1432-0827
    Keywords: Bone ; Magnetic field ; IR light ; Light absorption constant ; Efficiency
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Enhancement of photovoltage has been found in bone and its two major constituents when placed in a magnetic field in standard Hall geometry. Infrared light has been used for carrier excitation. From data obtained in this manner, values for the light absorption constant, extinction constant, mass absorption constant, and efficiency have been estimated. All these parameters increase with the increase of magnetic field. A possible explanation for the observed phenomena is presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    ISSN: 1432-0827
    Keywords: Vitamin D ; Vitamin D deficiency ; Cartilage ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary To test the importance of 24-hydroxylation of vitamin D3 on bone mineralization, rat pups born to vitamin D-deficient females were given either 25-hydroxyvitamin D3 or 24,24-difluoro-25-hydroxyvitamin D3 for 16 days beginning at the time of weaning. Following such treatment analysis of blood samples revealed no detectable 24R,25-(OH)2D3 and 1,25-(OH)2D3 in the rats given the difluoro compound while revealing the expected 24,24-difluoro-25-hydroxyvitamin D3 and 24,24-difluoro-1,25-dihydroxyvitamin D3. The rats given 25-hydroxyvitamin D3 had the expected levels of 25-hydroxyvitamin D3, 24,25-dihydroxyvitamin D3, and 1,25-dihydroxyvitamin D3. Following sacrifice at day 17, postweaning bone mineralization and modeling were studied in long bones using histological methods. Bones taken from vitamin D-deficient rats at the beginning and end of the experimental period had lesions typical of rickets. These included wide growth plates, excessive amounts of osteoid, and metaphyseal fibrosis. Following treatment with either 25-hydroxyvitamin D3 or 24,24-difluoro-25-hydroxyvitamin D3, bone mineralization returned to normal. Growth plate widths and the amount of osteoid on bone surfaces were both substantially reduced and to a similar degree in both treatment groups. Normal cartilage core formation and trabecularization of the metaphyseal primary spongiosa were also restored to a similar degree in both groups. In effect, no difference was observed in any bone parameter studied between the 25-hydroxyvitamin D3- and the 24,24-difluoro-25-hydroxyvitamin D3-treated animals. These results provide strong evidence that 24-hydroxylation of the vitamin D molecule plays little or no role in the modeling and mineralization of bone.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 655-661 
    ISSN: 1432-0827
    Keywords: 1,25-Dihydroxyvitamin D3 ; 25-Hydroxyvitamin D3 ; 24,25-Dihydroxyvitamin D3 ; Receptors ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The hormonal metabolite of vitamin D3, 1,25-dihydroxyvitamin D3 [1,25(OH)2D3], exerts its biological effects by binding to a cytosolic receptor protein. Such a protein has been demonstrated in vitamin D3 target organs including fetal rat calvariae and more recently in rat osteogenic sarcoma cells. In this study we have compared the binding of 25-hydroxyvitamin D3 [25(OH)D3] and 24,25-dihydroxyvitamin D3 [24,25(OH)2D3] to that of 1,25-(OH)2D3 in fetal rat calvariae and osteogenic sarcoma (OS) cells. Sucrose density sedimentation, DNA-cellulose chromatography, and intracellular uptake studies have been employed to evaluate these interactions. In cytosol preparations from calvariae, [3H]-1,25(OH)2D3 bound to a 3.3S macromolecule and to a much greater extent to a 5.8S macromolecule while both [3H]25(OH)D3 and [3H]24,25(OH)2D3 bound to the 5.8S macromolecule. By incubating intact calvariae and OS cells with labeled metabolites and thus establishing binding intracellularly prior to cell disruption, we have found that the 3.3S protein which has high specificity for 1,25(OH)2D3 occurs inside the cells; the 5.8S protein, however, does not occur inside the cells but is generated after cell disruption. The [3H]-1,25(OH)2D3-receptor complex adsorbed to DNA-cellulose and was eluted from this affinity resin at 0.28M KCl. In contrast, [3H]25(OH)D3 and [3H]-24,25(OH)2D3 binding activity did not adsorb to DNA-cellulose. We conclude that, in contrast to the 3.3S protein, the 5.8S macromolecule does not fulfill receptor criteria but is rather generated by the experimental manipulation of the bone cells. Our data suggest that the vitamin D3 actions on bone are mediated only via the 3.3S receptor, and hence quantitative but not qualitative differences of the effects of the various metabolites are feasible.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 22 (1977), S. 303-313 
    ISSN: 1432-0827
    Keywords: Osteoclasts ; Sedimentation ; Isolation ; Cells ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract A method is presented for separating osteoclasts from the heterogeneous population of bone and marrow cells. Cell suspensions were prepared from femora of young rabbits by mechanical dispersion. The starting cell suspension typically contained only 1.0%±0.5 osteoclasts. Following an initial 45 min of unit gravity sedimentation in a lucite chamber osteoclasts were primarily distributed in fractions 2–5. A second 45-min sedimentation of these pooled fractions yielded cell suspensions containing greater than 30% osteoclasts (as much as a 50-fold increase over starting percentages). Linear scan analysis, however, revealed that osteoclasts accounted for 73.14%±0.58 of the cell colume. Subsequent in vitro experiments demonstrated linear incorporation of3H-leucine into TCA precipitable protein for cells comprising the osteoclast fraction. Concomitant radiautographs revealed radioactive label in isolated osteoclasts.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    ISSN: 1432-0827
    Keywords: Bone ; Diphosphonates ; Bone resorption ; Bone formation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Male rats weighing 100 g were assigned to groups and injected daily for 10 days with vehicle (control), 0.4, 2.0, 4.0, 10.0, or 20.0 mg/kg/day of ethane-1-hydroxy-1,1-diphosphonate (EHDP) or dichloromethylene diphosphonate (Cl2MDP). The proximal tibial metaphysis and epiphysis were assayed for changes in percentage of hard tissue and bone formation parameters. From the data, information about hard tissue resorption was deduced. All doses of Cl2MDP and doses of 2.0 mg EHDP/kg/day and greater caused significant increases in percentage of hard tissues with Cl2MDP being more effective than similar doses of EHDP in decreasing bone resorption. Osteoclast population parameters were increased with all doses of both Cl2MDP and EHDP with Cl2MDP having a greater effect than similar doses of EHDP. Decreases in the proliferation of the osteoprogenitor pool parallel the decreases in osteoblasts and bone formation parameters. These decreases in osteoprogenitor pool proliferation do not account for the increases with diphosphonates in osteoclast population parameters.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 283-289 
    ISSN: 1432-0827
    Keywords: Bone ; Resorption ; Osteoclast ; Quantitation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The stimulation of bone resorption, assessed by the release of45Ca from prelabeled bones, was associated with an increase in number of osteoclasts per bone section in parathyroid hormone (PTH)-treated bones, but not in lipopolysaccharide (LPS)-treated bones. By contrast the number of nuclei per osteoclast increased following LPS treatment, but was not affected by PTH. LPS-treated bones had more multinucleated cells, some having as many as 27 nuclei per osteoclast. More osteoclasts were adjacent to the bone collar in bones treated with LPS or PTH than in control bones. In LPS-treated bones this area also contained the largest osteoclasts, as determined by the greatest number of nuclei per osteoclast. The results suggest that LPS and PTH stimulate osteoclastic resorption by different mechanisms.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 303-305 
    ISSN: 1432-0827
    Keywords: Albumin ; Bone ; Hydroxyapatite ; Plasma protein
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The extractability of125I-labelled plasma albumin from bone pieces and from powdered bone has been compared after both in vivo and in vitro incorporation. The results show that albumin is more readily extracted from bone pieces than from bone powder which implies that tissue disruption exposes additional protein adsorption sites. It is suggested that incorporation of plasma albumin into calcified matrix during bone formation occurs mainly as a result of its strong interaction with bone mineral.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 25 (1978), S. 217-222 
    ISSN: 1432-0827
    Keywords: Bone mineral ; Electron microscopy ; X-ray diffraction ; Dark field
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Electron microscopical observations of the size and shape of bone mineral crystallites have not been in complete agreement with X-ray diffraction findings. The two prevalent viewpoints consider bone mineral crystals to be either rod, or plate like in habit. There appears to be agreement that the smallest dimension of the crystals is about 5 nm, but there is discrepancy in the reported c-axial lengths. The method of dark field imaging is used to obtain a quantitative measurement of the c-axial length distribution in rabbit, ox and human bone: mean c-axial lengths 32.6 nm, 36.2 nm and 32.4 nm, respectively, show no significant difference at the 5% level to the mean c-axial length measured by X-ray line broadening. Both bright and dark field images strongly suggest that bone mineral has a plate like form. Reasons for past discrepancies are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 161-170 
    ISSN: 1432-0827
    Keywords: Bone ; Growth ; Rat ; Remodeling ; Tetracyclines
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Cortical bone remodeling along the femur diaphysis was determined in normal female rats (Sprague-Dawley) with the tetracycline technique. Three segments on the cortical bone circumference (the anterolateral, the medial, and the posterior) were found to be most suitable for the study of the remodeling process. Oxytetracycline was administered at age 60 and 75 days, and groups of animals were killed at age 75, 85, 95, and 105 days. The accumulated endosteal growth during age 60 to 75 days in the anterolateral segment was found to increase uniformly in the distal direction along the femur diaphysis. A method is described where this accumulated endosteal growth is used. This method eliminates the use of calipers to determine the section level and makes it possible to study comparable sections even after varying periods of time. The proximal part of the diaphysis showed periosteal apposition in all three segments. The periosteal apposition turned into resorption in the distal part of the diaphysis in the anterolateral and medial segments, whereas the periosteal appsition increased in the posterior segment. The endosteal growth increased in the distal direction in the anterolateral and medial segments. Irregular OTC bands made measurements of endosteal remodeling in the posterior segment impossible. The cortical width decreased in the distal direction along the femoral shaft. Comparison between the different age groups is described and also the relation between the accumulated endosteal growth and the diameter of the medullary cavity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 27 (1979), S. 177-185 
    ISSN: 1432-0827
    Keywords: Calcification ; Bone ; Glycoprotein ; Golgi ; Osteoblasts
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The elaboration of bone matrix glycoprotein by osteoblasts of alveolar bone was investigated by radioautography after the intravenous injection of3H-fucose into young rats. At selected times after injection, animals were sacrificed by intracardiac perfusion and demineralized specimens were prepared for light and electron microscope radioautography. At 5 and 10 min after injection, when the blood fucose level was high, silver grains were restricted to the spheroidal and cylindrical saccules of the Golgi apparatus. At 20 min membrane-limited secretory granules were also labeled. By 35 min, the blood fucose level had dropped and silver grains were detected over the apical cortical cytoplasm, in association with secretory granules located therein. Some grains were present over osteoblast processes and the adjacent prebone matrix. By 4 h most of the silver grains had left the cell. At that time they were observed over prebone, adjacent to osteoblast processes, as well as over the prebone-bone junction where a distinct band of label was noted. In demineralized preparations an electron-dense granular material was present at the prebone-bone junction in association with collagen fibrils. These findings provide evidence that osteoblasts in alveolar bone synthesize fucose-containing glycoprotein and indicate that the addition of3H-fucose occurs in the Golgi apparatus. The glycoprotein passes to the apical cortical cytoplasm by way of membrane-limited secretory granules, is exteriorized, and accumulates at the site where prebone transforms into bone (the prebone-bone junction). Since this is also the site of the calcification front, the deposition of labeled glycoprotein may be related to the deposition of bone mineral.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 1-5 
    ISSN: 1432-0827
    Keywords: Water ; Bone ; Homeostasis ; Structure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary A short review is given of the water in bone. Various analyses of bone water content are discussed, and its possible location is considered in relation to the behaviour of water in isolated components of bone. Some of the difficulties encountered in examining such microscopic phenomena as water structure in a heterogeneous system such as bone are also discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 24 (1977), S. 41-46 
    ISSN: 1432-0827
    Keywords: Lead salt ; Bone ; Mobilization ; Hypercalcemia ; Hyperphosphatemia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The present study is an investigation of the mechanism of hypercalcemia and hyperphosphatemia induced by the intravenous injection of lead acetate (Pb-Ac). A total of 118 male rats were injected with 30 mg/kg of Pb-Ac, or with 16.5 mg/kg of sodium acetate as the control. The levels of serum calcium, phosphorus and lead were then determined at various time periods after the injections. Serum calcium and phosphorus levels increased with time after Pb-Ac injection and the maximum values of calcium (17 mg%) were found after 1 h and of phosphorus (13.5 mg%) after 30 min. Both calcium and phosphorus levels reverted to the normal range after 12 h. The maximum net rates of increase of calcium and phosphorus were found immediately after Pb-Ac injection. At that time, deposition of lead at the calcifying sites of bone and incisor dentin was demonstrated by a histochemical examination. In other experiments the changes in the calcium and phosphorus contents in the medium after shaking bone powder in serum with Pb-Ac in an in vitro system were studied. It was confirmed that the calcium and phosphorus were displaced from the bone mineral, the extent of the displacement being correlated with the concentration of the Pb-Ac added to the medium, and that these displacements were very rapid reactions. These results suggest that hypercalcemia and hyperphosphatemia following Pb-Ac injection results from a direct action of lead on the bone mineral.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 27 (1979), S. 95-99 
    ISSN: 1432-0827
    Keywords: Bone ; Fluoride ; Analysis ; Food ; Age
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Recently published bone fluoride values from Iowa are very high compared to earlier reports, suggesting an increase in fluoride intake. Reanalysis of the Iowa specimens shows levels one-fourth those reported by the Iowa laboratory indicating an error in the original report. Seventeen bone specimens, collected from long-term residents of Rochester, New York, drinking 1 ppm F− water, had a mean value of 2085±270 ppm F− on an ashed-weight basis. This value is not significantly different from that predicted by the data of Zipkin et al. in 1958. These data, therefore, do not support the contention that there has been an increase in fluoride intake.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 24 (1977), S. 209-214 
    ISSN: 1432-0827
    Keywords: Parathyroid hormone ; Plasma calcium ; Radiocalcium ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The net rate of loss of45Ca from plasma was monitored in normal, thyroparathyroidectomized (TPTX), and nephrectomized rats. Also studied was the effect of a 24 h intravenous infusion of PTH in TPTX rats. The45Ca was injected after an overnight fast and 1 to 4 h prior to the time the first blood sample was obtained. In normal rats, the net rate of loss of45Ca from plasma was slower than in TPTX rats for at least 12 h after radionuclide injection. Nephrectomy did not affect this difference between control and TPTX rats until 8 h after45Ca injection or about 18 h after nephrectomy. At this time a reversal occurred and the net rate of plasma45Ca loss in nephrectomized rats with parathyroids became faster than in TPTX nephrectomized rats. When PTH was infused at a constant rate (3 mU/g body weight/h) plasma calcium concentrations rose gradually for approximately 12 h after which a constant plasma calcium level was maintained with continued PTH infusion. During the period when plasma calcium concentrations were rising, the net rate of loss of45Ca from plasma was slower than in TPTX controls infused only with saline. However, when plasma levels stabilized, plasma45Ca disappearance rates changed such that the rate loss of45Ca from plasma became faster in PTH-infused than in TPTX controls. It is concluded that PTH increases calcium efflux from the same compartment in bone which receives calcium from plasma, thereby returning some recently deposited45Ca to plasma. In the non-equilibrated state, this returns additional45Ca to plasma causing anet decrease in the rate of loss of45Ca from plasma. However, in the equilibrated condition, when both calcium efflux from bone and influx into bone are in balance but at higher flux rates, PTH stimulates the diffusion of45Ca into other bone compartments.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 28 (1979), S. 103-105 
    ISSN: 1432-0827
    Keywords: Bone ; Photodensitometry, X-ray ; Radiography ; Spectrophotometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary A conventional spectrophotometer was used to do radiographic photodensitometry of bone mass. An experiment to produce osteoporosis in guinea pigs required quantification of changes in bone mass. Lack of a densitometer necessitated finding another method for quantification. The method developed involved using industrial film in a closed X-ray system. Optical density of X-rays was then read in a spectrophotometer at nine femur locations. Highly significant correlations between optical density and femur calcium content and femur dry weight per millimeter were obtained. Histological sections from an animal with low optical density measurements confirmed bone loss by showing decreased cortical width and loss of trabecular bone. In addition to using readily available equipment, this method offers the advantage of being able to detect bone loss in specific areas of the bones. In addition, bones are left intact and can be used for other purposes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    ISSN: 1432-0827
    Keywords: ESR ; Bone ; Enamel ; CO3-Apatite ; Paramagnetism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Carbonate-containing hydroxyapatite, enamel, and bone were irradiated by an X-ray and investigated between 77° and 350°K by means of electron spin resonance (ESR) spectroscopy. The ESR spectrum of enamel irradiated at 77°K in vacuum and observed at the same temperature was almost the same as that of the carbonate-containing hydroxyapatite. The temperature dependence of signal intensities confirms a spin-energy exchange between the mineral and organic constituents in bone, but in enamel no or very little spinenergy exchange between the mineral and organic constituents. Considerable similarity among the ESR spectra of enamel, bone, and carbonate-containing apatite was obtained after X-ray irradiation in air at 300°K with both an X-band and a Q-band ESR spectrometer. The Q-band spectrum can be interpreted in terms of two paramagnetic species. One is identified as a CO 3 3− anion radical which has an axial symmetry withg factors of 2.0029 and 1.9972. The other species is found to be centered atg=2.0019.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 28 (1979), S. 33-36 
    ISSN: 1432-0827
    Keywords: Infrared, visible light ; Bone ; Collagen ; Apatite
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Photovoltaic effect (infrared and visible light) is observed in bone and its two major components, collagen and apatite, at room temperature. A dimunition in the magnitude of photovoltage is observed after exposure to ultraviolet light in all the cases. The drift mobility of the charge carriers is obtained by measuring I versus V relationships in sandwich samples and relating them to the permitivity of the medium. Lifetime of the injected carriers is measured in the usual way. The data are consistent with the hypothesis that the effects are due to protonic conduction phenomena.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 26 (1978), S. 47-49 
    ISSN: 1432-0827
    Keywords: Matrix vesicles ; Calcospherites ; Mineralization ; Bone ; Dentin ; Cartilage ; SEM
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Mineral particle cluster, corresponding to calcospherites or matrix vesicle-initiated clusters in calcifying cartilage and dentin and to collagen bundle-related mineralization in lamellar bone, have been isolated from NaOCl solutions used to dissolve the organic matrix in preparation of anorganic mineralizing fronts for scanning electron microscopy.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 26 (1978), S. 81-84 
    ISSN: 1432-0827
    Keywords: Osteoclasts ; Bone ; Resorption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Osteoclastic bone resorption involves the solubilization of the mineral salts and the degradation of noncollagen bone matrix and collagen fibrils. As no recognizable collagen fibrils have ever been reported within cytoplasmic vacuoles in osteoclasts, it is generally assumed that the collagen fibrils are digested extracellularly in the resorption zone. The extent to which lysis occurs extracellularly and whether or not the osteoclasts phagocytose the degradation products remain to be established. In the present communication, a hypothesis is presented suggesting the possibility that osteoclastic resorption of bone involves the participation of two different cell types. According to this hypothesis, osteoclastic bone resorption is initiated by osteoclasts that demineralize areas of bone and degrade noncollagen bone matrix. After the osteoclasts have moved away or become partially detached from the demineralized site, the exposed collagen fibrils are phagocytosed by mononuclear, fibroblast-like or monocyte-derived cells.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 26 (1978), S. 155-161 
    ISSN: 1432-0827
    Keywords: Plasma protein ; Glycoprotein ; Bone ; Glucosamine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Plasmaα 2HS-glycoprotein is specifically accumulated in calcified tissues. In the present studies this glycoprotein was isolated from plasma and after iodination with iodine-125 was injected intravenously into young rabbits. The tissue distribution and plasma disappearance rate of this radioactively labeled material were determined. Of the various tissues studied, bone showed the greatest retention of labeled glycoprotein expressed as percentage of the injected dose per gram tissue relative to the plasma content. The rate of loss of iodinatedα 2HS-glycoprotein from plasma was similar to that ofα 2HS-glycoprotein labeled endogenously by using14C-glucosamine or3H-glucosamine. The uptake of exogenously labeled3I-α 2HS-glycoprotein into bone tissue expressed as a percentage of the injected dose was similar to that of endogenously labeled14C-α 2HS-glycoprotein. These results suggest that the125I-labeled material can be used to study further the metabolism ofα 2HS-glycoprotein by bone tissue.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 26 (1978), S. 209-213 
    ISSN: 1432-0827
    Keywords: Mithramycin ; Bone ; β-Glucuronidase ; KT medium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Mithramycin suppresses bone resorption. Its effect on the synthesis and release of β-glucuronidase (a referent for lysosomal enzymes) in mouse calvarial explants was studied in an in vitro culture system. A newly described medium (designated as KT medium) was introduced in this specific study. Mithramycin initially inhibited the release of β-glucuronidase into the medium and resulted in an ultimate accumulation of this enzyme in the bone. These results suggest that inhibition of bone resorption by mithramycin may be attributed to interference in release of lysosomal enzymes from bone cells.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    ISSN: 1432-0827
    Keywords: Parathyroid hormone ; Osteoclasts ; Electron microscopy ; Morphometry ; Metaphysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The effects of parathyroid hormone (PTH) on the size of the osteoclasts, nuclei, ruffled borders, and clear zones in long bones of thyroparathyroidectomized (TPTX) rats were quantitated as a function of time. These data were compared with the number of osteoclasts in the bone and with plasma calcium levels. A significant increase in the average size of the ruffled borders was demonstrated 30 min after injection of 50 U of purified bovine PTH, and of the clear zones 30–90 min after PTH. This was followed at 90 min by an increase in the average size of the cells. The sizes of ruffled borders and clear zones dropped sharply to control levels after 6 h, whereas the size of the cells remained elevated up to 12 h and returned to control values at 24 h. Plasma calcium levels were increased, but not significantly, between 30 min and 6 h. An increase in the number of osteoclasts was significant after 12 h. Removal of the parathyroid glands did not diminish the normal activity of osteoclasts. In animals with intact glands injection of 50 U of PTH did not cause a significant change in cell size or resorbing apparatus. It is concluded that PTH acts to rapidly stimulate the bone resorptive activity of osteoclasts and to cause a delayed increase in their number.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    ISSN: 1432-0827
    Keywords: Vitamin D ; Bone ; Osteoblasts ; Receptors ; 1,25-dihydroxyvitamin D3
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Thaw-mount autoradiographic studies after injection of3H-1,25-D3 were conducted on 18-and 20-day-old rat fetuses. In maxillary bones, ribs, and tibia, nuclear concentration of radioactivity was found in osteoprogenitor cells and osteoblasts. Osteocytes and chondrocytes in epiphyseal plates were either unlabeled or weakly labeled. In competition experiments, nuclear concentration of radioactivity was blocked by the injection of a high dose of nonradioactive 1,25-D3 prior to the administration of the labeled hormone, but not by a similar dose of nonradioactive 25-D3. The results are interpreted as indicating that osteoprogenitor cells and osteoblasts are target cells for the direct action of 1,25-D3 on fetal bone.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    ISSN: 1432-0827
    Keywords: Vitamin D ; Vitamin D deficiency ; Bone ; Cartilage ; Bone development
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The role of vitamin D in early skeletal development was studied by measuring serum calcium and phosphorus, osseous tissue quantity and mineralization, and endochondral bone elongation in rat fetuses and pups from vitamin D-replete and vitamin D-deficient mothers. At the 20th day of pregnancy there was a slight, yet significant, increase in the amount of osteoid on trabecular bone surfaces in fetuses from vitamin D-deficient mothers. The fetal bones otherwise appeared normal in spite of severe skeletal changes in the vitamin D-deficient mothers. After parturition, the importance of vitamin D in skeletal development becomes progressively more obvious. Serum calcium levels were slightly, yet significantly, lower in vitamin D-deficient than in vitamin D-replete pups and these levels continued to fall in the vitamin D-deficient pups through lactation and after weaning. At 3 days postpartum, there was a small, yet significant, increase in the amount of osteoid on bone surfaces of the vitamin D-deficient pups. The relative amounts of osteoid in the vitamin D-deficient pups continued to increase through lactation and after weaning when compared with vitamin D-replete pups. By the 14th day of lactation and at later periods, there were significant reductions in metaphyseal mineralized tissues in the vitamin D-deficient pups when compared with the vitamin D-replete pups. At weaning and after weaning, there were substantial increases in growth plate thickness and decreases in longitudinal bone growth in the vitamin D-deficient pups when compared with the vitamin D-replete pups. The results from this study indicate that vitamin D does not appear to play a major role in fetal skeletal development. However, after birth, vitamin D becomes progressively more important with age for normal bone development, mineralization, and endochondral growth.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 35 (1983), S. 481-485 
    ISSN: 1432-0827
    Keywords: Chemotaxis ; Bone ; Osteoblasts ; Bone proteins
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary When demineralized bone matrix powder is implanted subcutaneously in the rat, the early responses involve the appearance and proliferation of mesenchymal cells at the site of implantation, followed by cartilage and bone formation. The ability of cells to migrate to the implant suggests that chemotaxis may be a critical event in this process. Therefore, using the modified Boyden chamber assay, we tested extracts of demineralized bone matrix for chemotactic activity. We have identified and partially purified, on molecular sieve chromatography, a heat labile and trypsin-sensitive protein (Mr=60,000–70,000) that is a potent chemoattractant for mouse calvaria, osteoblast-like cells (MMB-1), but not for monocytes (putative osteoclast precursors). These findings suggest that chemotactic protein(s) have a significant role in the recruitment of osteoprogenitor cells to a site of bone repair.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 35 (1983), S. 762-766 
    ISSN: 1432-0827
    Keywords: Enamel ; Maturation cycles ; Tetracycline ; Dentine ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Uptake of tetracycline by enamel in the short-term was studied at an advanced stage of crown formation and after completion of crown formation in deciduous molars in the cat. Both secretory phase enamel and bands of postsecretory, maturation phase enamel labeled rapidly. The pattern of labeling mimicked that seen in the continuously growing, rootless incisor teeth of the rat, with narrow doublets fusing to form narrow bands with wide unlabeled intervals in the short term. This is a physiological demonstration which indicates that cyclical activity and changes may occurin vivo during the maturation phase of amelogenesis in rooted teeth. It is also noted that dentine did not, and that some circumscribed patches of bone did label in the same animals in the same time interval. Short-term tetracycline labels are lost following conventional histological processing, but are retained after freeze-drying or air-drying.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 36 (1984), S. S25 
    ISSN: 1432-0827
    Keywords: Remodeling ; Bone ; Stress
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary It has long been known that the stress history of bone tissue influences its structure; however, the nature of this relationship remains largely uncharacterized. The objective of this work was to induce a quantifiable change in the stress history ofin vivo bone tissue and examine subsequent changes in structural and material properties that might occur. Continuous compressive loads were applied to the diaphysis of adult mongrel dogs for 2 months. The loads, ranging from 12–130 N, were superposed on the normal activity of the animals by implanting spring loading devices on the diaphysis of the femur. After the animals were sacrificed, mid-diaphysial specimens were subjected to compression testing to determine a structural bulk stiffness. The cross-sectional areas of original bone tissue and new bone deposition were then determined. The ash weights of selected specimens were also determined. The results indicate that a positive correlation between the increase in cross-sectional area and the superposed stress does exist. The new bone apposition was found almost entirely on the periosteal surface. Very little evidence of internal remodeling or endosteal movement was observed. The new tissue was found to have a lower ash weight and appeared to have a disorganized microstructure. Mechanical testing also suggests that the newly deposited tissue is far less stiff than the mature original bone.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 34 (1982), S. 439-448 
    ISSN: 1432-0827
    Keywords: Bone ; Histomorphometry ; Osteocytes ; Bone dynamics ; Histology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary A new semiautomatic technique combining advantages of the manual and fully automatic methods is described for obtaining quantitative static and dynamic histologic data of bone. The hardware consists of a photomicroscope, digitizing platen, digitizer, plotter/printer, floppy disc drive, and computer. The microscope is equipped with a drawing tube through which the image of the digitizing platen is projected over the optical field. The investigator selects and traces all histologic structures to be measured by moving a cursor on the digitizing platen which is visible by its projection over the histologic field. The results on accuracy and static and dynamic precision of this method show that static and dynamic parameters of bone are obtained with a degree of error (〈20%) well within the acceptable range for biologic measurements. Comparison of this method with the grid technique according to Merz and Schenck showed that for almost all micromorphometric parameters comparable absolute data are obtained. Due to the higher precision of our method, however, the number of optical fields evaluated in obtaining these comparable data could be reduced to 25% of the number of fields evaluated by the Merz and Schenck technique. The time requirements for quantitative evaluation of a histologic slide of bone by our technique are 40–50 min; 20–25 min is needed for quantitative evaluation of osteocytes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 34 (1982), S. 449-455 
    ISSN: 1432-0827
    Keywords: Bone ; Histomorphometry ; Normal values ; Bone biopsies ; Sampling error
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Quantitative bone histology was done in undecalcified sections of iliac crest bone specimens obtained from 84 normal American individuals. Samples were obtained within 12 h after death in a vertical and horizontal manner from both the right and left iliac crests. In addition to the determination of normal values of micromorphometric parameters of bone in these healthy American subjects, the following studies were carried out: (a) comparison of variance of micromorphometric parameters of bone obtained from the right versus left iliac bone (40 pairs), (b) comparison of micromorphometric parameters of bone obtained in a vertical versus horizontal manner (12 pairs), (c) evaluation of variance with increasing distance from the compact zone in bone samples obtained in a vertical manner (44 pairs), (d) analysis of variation between bone samples obtained more anteriorly versus posteriorly along the iliac crest (N=40), (e) comparison of differences in micromorphometric parameters obtained from age-matched men versus premenopausal women (N=12), and (f) plotting of histograms for assessment of distribution of micromorphometric parameters. The results show that histomorphometric data of bone cannot be easily compared when different techniques are employed for obtaining bone samples. Sampling variations are kept smaller when bone specimens are obtained in a vertical manner. Anterior/posterior variation does not cause major sampling error. If ranges of variation are taken into account, quantitative bone histology is a valuable tool for assessment of bone structure and bone cells.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 35 (1983), S. 148-152 
    ISSN: 1432-0827
    Keywords: Bone ; Computed tomography ; Densitometry ; Osteoporosis ; Osteomalacia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The linear attenuation coefficient (μ in cm1) of trabecular bone was modeled for different conditions of bone and marrow composition in order to assess their influence on computed tomography (CT) quantitation. A large relative change (10% of TBV at 15% TBV) of bone concentration resulted in small changes of μ: 2.3% at 60 keV, 3.4% at 44 keV, 5.2% at 29 keV. Relative changes of trabecular bone volume (TBV) on the order of 3% could be detectedin vivo by CT were it not for errors of relocation and for compositional influences on accuracy. The μ (and density) depended critically not only on amounts of bone substance and marrow but on their compositions. Normal variation in the composition of bone substance produced an uncertainty in μ equivalent to 0.5 to 1% TBV. Increases of yellow marrow produced a decrease of μ which could be mistaken for a decrease of bone concentration. The biological variation (90% confidence limit) of marrow composition gives an uncertainty at 15% TBV of about 2.4% TBV at 60 keV, 1.7% at 44 keV, and 1.3% at 29 keV. These correspond to relative uncertainities of 16, 11, and 9% respectively. These factors help explain the large accuracy errors (30%) observed in all studies of trabecular bone where single-energy CT was used. Marrow composition also can affect precision of bone measurement. Systematic shifts of red and yellow marrow could mask biological changes such as those occurring with aging or treatment.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Springer
    Mycopathologia 60 (1977), S. 175-177 
    ISSN: 1573-0832
    Keywords: Aspergillus fumigatus ; Spore formation ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Springer
    Mycopathologia 61 (1977), S. 117-119 
    ISSN: 1573-0832
    Keywords: Prototheca ; Colorless alga ; Plastids ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract An ultrastructural investigation of six different species of Prototheca showed that all of them contained starch grains enclosed in double-membrane-bounded structures recognized as plastids. It is concluded that these unicellular species of Prototheca must be considered as non-photosynthetic algae.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    ISSN: 1573-0832
    Keywords: Trichophyton mentagrophytes ; Thiocyanatopyrazole derivatives ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Four thiocyanatopyrazole derivatives were synthesized and their fungistatic activity was demonstrated in vitro against a number of dermatophytic fungi. In Trichophyton mentagrophytes, the most active compound induced an unusual increase of the plasma membrane with production of intra and extracytoplasmic complexes, a deterioration of nuclear and mitochondrial membranes and a formation of autophagic-like vacuoles. Plasmolysis, accompanied by an almost complete disorganization of cytoplasmic structures, seemed to be the final event. A possible mechanism of action of the compounds was discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 26 (1981), S. 133-140 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Single-mode selection with Michelson selectors in cw standing-wave dye lasers is analyzed. The application of single and double Michelson mode selectors for compensation of spatial hole burning effects is described in detail. Upper limits for the pumping are considered. It is shown that with spatial hole burning compensation, even the single Michelson selector provides sufficient selectivity for high power single-mode operation in linear cavities.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 27 (1982), S. 19-25 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract New laser lines have been generated using methanol when isotopically labelled CO2 is used in the pump laser. 19 lines have been found when13C16O2 is used and 29 when12C18O2 is used. The wavelengths of the emission lines have been measured with a relative accuracy of 5×10−3 using the submillimetre resonator as a scanning Fabry-Perot interferometer, and the polarizations of the lines have also been measured. Some of the laser lines have been assigned to pure rotational transitions in the excited state associated with the CO stretching mode, other lines are believed to originate from pumping in combination bands.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 8 (1975), S. 319-331 
    ISSN: 1432-0630
    Keywords: Self-interstitials in silicon ; Swirls ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Point defect agglomerates in dislocation-free silicon crystals, usually called “swirls”, have been investigated by means of high-voltage electron microscopy. It was found that a single swirl defect consists of a dislocation loop or a cluster of dislocation loops. By contrast experiments it could be shown that these loops are formed by agglomeration of self-interstitial atoms. Generally the loops have a/2〈110〉 Burgers vectors, but in specimens with high concentrations of carbon (∼1017 cm−3) and oxygen (∼1016 cm−3) also dislocation loops including a stacking fault were observed. In crystals grown at growth rates higher thanv=4 mm/min no swirls are observed; lower growth rates do not markedly affect the size and shape of the dislocation loops. With decreasing impurity content (particulary of oxygen and carbon) the swirl density decreases, whereas the dislocation loop clusters become larger and more complex. A model is presented which describes the formation of swirls in terms of agglomeration of silicon self-interstitials and impurity atoms.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 27 (1982), S. 177-181 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A new method of pulse width measurement based on the total energy response of an etalon is presented. The theory is developed and results for several pulse shapes are given. The method is unique because no fast response detector is required and there are practically no spectral region limitations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    ISSN: 1432-0649
    Keywords: 42.80 ; 42.65 ; 34 ; 42.55 ; 42.70 ; 78
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    ISSN: 1432-0649
    Keywords: 42.55 ; 36.20 ; 36.10 ; 02 ; 36 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 26 (1981), S. 193-195 
    ISSN: 1432-0649
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A simple method for single-frequency operation and stabilization of a low power He−Ne laser has been described and used. With a proper resonator length very weak sideband modes on each side of the strong mode produce a feedback signal to a piezoelectric pusher which controls the resonator length. The long-term frequency stability was estimated to be about ±10 MHz.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    ISSN: 1432-0649
    Keywords: 41 ; 42.55 ; 95
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Exact expressions are derived for the gain of a free-electron laser based on a uniform longitudinal magnetic field configuration operating in the single-particle, low-gain regime. The gain is calculated for different parameters of the system. For strong enough a field, the gain decreases with an increase of the amplitude, becoming negative when passing a threshold value, which depends on the system parameters. Implications regarding the saturation of the lasing process are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    ISSN: 1432-0649
    Keywords: 33.80 Bx ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract In this work, clear FIR Raman emission in ammonia was observed when a 9P20 CO2 line was used as a pump. We have noted an intense pump depletion and strong superradiant FIR and MIR emissions. The time history of these radiations has also been recorded. The intense MIR radiation is a new line observed in the ammonia laser.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...