ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Gas chromatography  (165)
  • Electron microscopy
  • Wiley-Blackwell  (119)
  • Springer  (99)
  • Annual Reviews
  • Blackwell Publishing Ltd
  • 2005-2009
  • 1990-1994
  • 1980-1984  (218)
  • 1970-1974
  • 1984  (96)
  • 1982  (122)
Collection
Publisher
  • Wiley-Blackwell  (119)
  • Springer  (99)
  • Annual Reviews
  • Blackwell Publishing Ltd
Years
  • 2005-2009
  • 1990-1994
  • 1980-1984  (218)
  • 1970-1974
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 260 (1982), S. 564-569 
    ISSN: 1435-1536
    Keywords: lin. Polyethylene ; Single crystals ; Heat of Fusion ; DSC ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Recently published results for solution crystallized PE single crystals have shown, that the experimental heat of fusionΔH * is higher, if the solvent is exchanged to silicon oil (oil suspension samples) as compared with dried mats. This has been interpreted by the collapse of the original hollow pyramids during drying, inducing lateral defects within the lamellae. The present investigation does not confirm this unexpected result.ΔH * of dried mats (T c 66 to 91 °C) and of the corresponding oil suspension samples agree within the rather small limits of experimental error. The crystallinities as derived fromΔH *, density or WAXS are in excellent agreement. SEM micrographs of cold fractured dried mats show their spongy macromorphology, but TEM micrographs of stained ultra-thin sections reveal the lamellar morphology of the walls, consisting of curved lamellae and stacked hollow pyramides. If a dried mat is sintered at room temperature, a dense transparent film is obtained with a rather regular stacked morphology of large flat lamellae.ΔH * of these films agrees with that of the original mat.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Development genes and evolution 191 (1982), S. 205-207 
    ISSN: 1432-041X
    Keywords: Chitin inhibition ; Nikkomycin ; Cuticle ; Electron microscopy ; Epilachna varivestis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary The nucleoside antibiotic nikkomycin has proved to be an effective inhibitor of chitin synthesis in the Mexican bean beetleEpilachna varivestis. Ultrastructural investigations show defects in the procuticular area after nikkomycin application which suggest the complete absence of chitin. A cuticle like this is inflexible and too brittle to satisfy its normal function as an exoskeleton. The individuals are not able to free themselves from the exuvia and finally die. Therefore nikkomycin seems to be a potential insecticide with high specifity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Archives of microbiology 138 (1984), S. 273-277 
    ISSN: 1432-072X
    Keywords: Cyanobacteria ; Secondary metabolite ; Allelopathy ; Photosynthesis ; Electron transport ; Thylakoids ; Herbicides ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Cyanobacterin is a secondary metabolite produced by the cyanobacterium, Scytonema hofmanni. Highly purified cyanobacterin was found to inhibit the growth of many cyanobacteria at a minimum effective dose of 2 μg/ml (4.6 μM). The antibiotic had no effect on eubacteria including the photosynthetic Rhodospirillum rubrum. The site of action of cyanobacterin was further investigated in the unicellular cyanobacterium, Synechococcus sp. Electron micrographs of antibiotic-treated Synechococcus cells indicated that cyanobacterin affects thylakoid membrane structure. The antibiotic also inhibited light-dependent oxygen evolution in Synechococcus cells and in spheroplasts. These data support our conclusion that cyanobacterin specifically inhibits photosynthetic electron transport. This activity is similar to herbicides such as 3-(3,4-dichlorophenyl)-1,1-dimethyl urea (DCMU). The anhydro analog of cyanobacterin had no biological activity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Archives of microbiology 132 (1982), S. 10-13 
    ISSN: 1432-072X
    Keywords: Calcofluor White ; Cell wall structure ; Chlorella ; Electron microscopy ; Protoplast ; Ruthenium Red
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Among 12 strains ofChlorella ellipsoidea, C. vulgaris, andC. saccharophila tested, 4 strains (1,C. ellpsoidea; 2,C. vulgaris; 1,C. saccharophila) formed osmotically labile protoplasts after treatment with mixtures of polysaccharide degrading enzymes. The relationship between enzymatical digestibility and structure or composition ofChlorella cell walls were studied by electron microscopy and staining techniques with some specific dyes. The cell wall structures of the 12Chlorella strains were grouped into three types: (1) with a trilaminar outer layer, (2) with a thin outer monolayer, and (3) without an outer layer. Protoplasts were formed only from the strains with a cell wall of Type 2. In the strains with a cell wall of Type 1, the outer layer protected the inner major microfibrillar layer against enzymatic digestion. The cell wall of Type 3 was totally resistant to the enzymes; the chemical composition of the cell wall would be somewhat different from that of other types.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Archives of microbiology 140 (1984), S. 265-270 
    ISSN: 1432-072X
    Keywords: EcoRI ; EcoRI-DNA complexes ; EcoRI* activity ; Recognition sites ; Frequency of binding ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Electron microscopy of negatively stained isolated restriction enzyme EcoRI revealed particle projections with triangular or square outlines, indicating that the enzyme, in its tetrameric state, is tetrahedron-like. The two dimers making up the tetramer appear to be arranged in two planes orthogonal to each other. Complexes formed by EcoRI with the plasmids pBR322 or pGW10 were investigated by electron microscopic spreading techniques. In the presence of Mg2+, EcoRI was bound to the DNA molecules to form pearl necklace-like aggregates. The number of bound EcoRI particles was much higher as the sum of EcoRI-and 5′..AATT..3′ sites (with exceptions, the 5′..AATT..3′ sites may function as one type of EcoRI* sites) along the DNAs, indicating unspecific binding. In the absence of Mg2+, EcoRI was bound to the DNA only at the recognition site for EcoRI and the sites where the tetranucleotide sequence 5′..AATT..3′ was present. A direct correlation of the local concentrations of the bases A and T within the flanking sequences of the binding sites with the frequency of EcoRI to the DNA was observed. Dimers and tetramers of the enzyme was found to bind to the DNA. Tetramers occasionally exhibited two binding sites for DNA as indicated by the observation of DNA loops originating at the sites of bound tetrameric EcoRI particles.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Archives of microbiology 133 (1982), S. 97-99 
    ISSN: 1432-072X
    Keywords: Cyanobacteria ; Thylakoid centers ; Photosynthetic membranes/thylakoids ; Membranes ; Membrane biogenesis ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract An ultrastructural study of four cyanobacteria (Anabaena cylindrica, Dermocarpa violaceae, Gleocapsa alpicola, Pleurocapsa minor) indicates the presence of previously undescribed thylakoid centers from which photosynthetic membranes (thylakoids) radiate. These peripherally located thylakoid centers are cylinders 30 nm wide by 320 nm long, consisting of globular subunits oriented in nonparallel stacked arrays. Thylakoids are attached to the outer surface of the cylinder along its longitudinal axis. Thylakoid centers appear to be functionally significant due to their structure, location and thylakoid association.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Archives of microbiology 131 (1982), S. 116-123 
    ISSN: 1432-072X
    Keywords: Cell wall ; Wall degradation ; Lysozyme ; Autolysines ; Electron microscopy ; Staphylococcus aureus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract In contrast to former findings lysozyme was able to attack the cell walls ofStaphylococcus aureus under acid conditions. However, experiments with14C-labelled cell walls and ribonuclease indicated that, under these conditions, lysozyme acted less as an muralytic enzyme but more as an activator of pre-existing autolytic wall enzymes. Electron microscopic studies showed that under these acid conditions the cell walls were degraded by a new mechanism (i.e. “attack from the inside”). This attack on the cell wall started asymmetrically within the region of the cross wall and induced the formation of periodically arranged lytic sites between the cytoplasmic membrane and the cell wall proper. Subsequently, a gap between the cell wall and the cytoplasmic membrane resulted and large cell wall segments became detached and suspended in the medium. The sequence of lytic events corresponded to processes known to take place during wall regeneration and wall formation. In the final stage of lysozyme action at pH 5 no cell debris but “stabilized protoplasts” were to be seen without detectable alterations of the primary shape of the cells. At the same time long extended ribbon-like structures appeared outside the bacteria. The origin as well as the chemical nature of this material is discussed. Furthermore, immunological implications are considered.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 237 (1984), S. 219-226 
    ISSN: 1432-0878
    Keywords: Spermatogonia ; Spermatocytes ; Carbohydrates ; Guppy ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The structure of guppy (Poecilia reticulata) spermatogonia and spermatocytes has been studied using electron microscopy. The spermatogonia, situated at the apex of the seminiferous tubule, are almost all surrounded by a network of Sertoli cells; they have very diffuse chromatin and one or two large nucleoli. The cytoplasm contains relatively few organelles, although annulate lamellae are found. The mitochondria have few cristae and are concentrated at one pole of the cell; they are sometimes found with intermitochondrial cement. These spermatogonia are separated from each other, having no intercellular bridges or inclusion in Sertoli cells, and are relatively undifferentiated; they correspond to stem cells. The spermatogonia beneath the apex are organized into cysts. First-generation spermatogonia are more dense and heterogeneous, their nuclei becoming smaller and their chromatin becoming denser during successive generations. In spermatocytes, the synaptinemal complex exists as a modified form until metaphase. The concentration of organelles in the cytoplasm increases and the organelles become more diversified as spermatogenesis progresses. Many cytoplasmic bridges are observed (several per cell), indicating that the cells remain in contact after several divisions. These changes in germ cell structure have been related to some of the characteristic features of spermatogenesis in guppy, e.g. the large number of spermatogonial generations and the complexity of spermiogenesis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 238 (1984), S. 413-416 
    ISSN: 1432-0878
    Keywords: Peroxisomes ; DAB-cytochemistry ; Electron microscopy ; Liver, amphibian ; Gymnophiona ; Ichthyophis glutinosus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The ultrastructure of hepatic peroxisomes was investigated in Ichthyophis glutinosus (Amphibia: Gymnophiona), employing perfusion fixation and the diaminobenzidine (DAB) technique for the visualization of catalase. The majority of peroxisomes is circular or rod-shaped, although elongated particles occasionally occur. They contain a finely granular matrix, lightly stained after the DAB procedure. Their mean diameter is approximately 0.25 μm. Serial sections reveal that the circular and rod-shaped peroxisomal profiles are cross and oblique sections of highly tortuous, tubular organelles exceeding 2 μm in length. In addition to tubular profiles, elongated, rectangular particles, as well as straight dumbbell-shaped organelles with distinct marginal plates are observed. They range from 900 to 1650 nm in length (mean = 1200 nm). In the flattened, thin central portion of the dumbbell-shaped particle, the peroxisomal membranes form a cisterna enclosing one or two uniformly thick marginal plates, which display a definite substructure with a periodicity of 10 nm. These findings indicate that peroxisomes in the liver of Ichthyophis exhibit a complex organization. It is suggested that the organelles undergo a specific differentiation process, morphologically characterized by the formation of enlarged segments of unusual shape.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-0878
    Keywords: Ovulation (rabbit) ; Graafian follicle ; Perfusion ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Isolated ovaries from untreated, sexually mature rabbits were introduced into an in vitro perfusion system and perfused with a chemically defined medium containing albumin. The ovaries were perfused for up to 15 h (mean 11.5 h) and then processed for morphological investigation. Both at the light- and electron-microscopical levels, most of the ovaries exhibited a normal structure comparable with ovaries in situ. In two cases, however, marked accumulations of bacteria were found, although not inside the follicles. Since ovulation in the rabbit normally occurs between 9.5–13 h after mating or human chorionic gonadotrophin treatment, this model seems adequate for studies of ovulation in vitro. It is, however, important to study the ovaries microscopically after the perfusion to detect artifacts, e.g., bacterial infection, that may have influence on the process of ovulation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    ISSN: 1432-0878
    Keywords: Tannic acid ; Acetylcholine receptors ; Tissue culture ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Spinal cord neurons from 9-day chick embryos were maintained in culture for up to 35 days and then fixed in 4% cacodylate-buffered glutaraldehyde containing 2% tannic acid. After about 15 days in culture a small percentage of the synaptic specializations present were characterized by striking electron-dense striations averaging 15 nm in width, oriented perpendicular to the postsynaptic membrane. These structures increased in frequency with time in culture (to a maximum of about 10% of all synapses in the oldest cultures); they were asymmetrical, protruding approximately 8 nm into the synaptic cleft, and more deeply (approximately 15–18 nm), into the postsynaptic cytoplasm. On the basis of earlier work by Sealock (1980) they are interpreted as concentrations of acetylcholine receptors. Similar membrane differentiations were also seen associated with active-zone areas of a few presynaptic membranes, and the possibility that these represent presynaptic acetylcholine receptors is discussed. Additional observations reported are (1) the presence of striations resembling those seen at the postsynaptic membrane in the membranes of some postsynaptic vesicles, and (2) filamentous links between the striations and cytoskeletal elements of the postsynaptic cell.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1432-0878
    Keywords: Monoamine-containing cells ; Taste bud ; Paracrine cells ; Mechanoreceptors ; Electron microscopy ; Teleosts
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The taste buds on the barbels in three species of teleosts (Cyprinus carpio, Misgurnus anguillicaudatus, Parasilurus asotus) were studied by means of fluorescence and electron microscopy. Intensely yellow-fluorescent cells, which are disk-shaped and located exclusively in a basal position, are observed in the barbel-buds of all fishes examined. The basal cells contain a large number of small clear vesicles approximately 40–60 nm in diameter, which show a tendency to aggregate in the cytoplasm facing the junction of the nerve terminals; chemically transmitting synapses are seen in the latter region. It is suggested from the present observations that the basal cells in the barbel-bud may originate from Schwann cells and have a dual function both as mechanoreceptors and paracrine elements. Since the administration of 5,6-DHT results in an appearance of small dense vesicles among the small clear vesicles, the possibility exists that the basal cell may be capable of taking up monoamines and storing them in the small clear vesicles.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1432-0878
    Keywords: Exocrine pancreas ; Calcium pool ; Calcium release ; Electron microscopy ; Rat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary In an attempt to identify a cellular Ca2+-pool, from which calcium is released when secretagogues are applied, tissue fragments of the rat exocrine pancreas were incubated and fixed with glutaraldehyde in the presence of calcium. By means of this procedure electron-dense deposits were found on plasma membranes. X-ray microanalysis showed that these deposits contain calcium. Stimulation of tissue fragments with the use of the secretagogues carbachol or cholecystokinin reduced the number of deposits by about 80%. When the antagonist atropine was applied after carbachol stimulation, deposits reappeared on cell membranes, which then disappeared again after a second stimulation with cholecystokinin. In the presence of procaine, carbachol was inhibited and only slightly reduced the Ca2+-deposits on the plasma membranes. These results suggest that a calcium pool, from which calcium is released to induce enzyme secretion on stimulation, is located in the cell membrane
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1432-0878
    Keywords: Chloride cells ; Acid stress ; Gill ; Electron microscopy ; Fathead minnow
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Fathead minnows, Pimephales promelas, were exposed for 129 days to Lake Superior water acidified with sulfuric acid by means of a flow-through toxicant injection system. The effects of chronic acid stress (pH 6.5, 6.0, 5.5, 5.0) on gill histology were examined. Most of the histological effects were seen at pH 5.5 and 5.0 and were confined primarily to changes in numbers, distribution, and morphology of chloride cells. At low pH levels there tend to be more chloride cells in the gill epithelium and an increased percentage of these cells in the secondary lamellae. In contrast to normal chloride cells, chloride cells from fish exposed to low pH frequently had apical pits while some had bulbous apical evaginations. The occurrence of structural changes in chloride cells during exposure to acid water suggests that chloride cells may be involved in acclimation to acid stress.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 1432-0878
    Keywords: Lactating cell ; Lipid droplets ; Secretory vesicles ; Mitochondria ; Intracellular associations ; Electron microscopy ; Milk secretion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The size, cellular location, and identity of surface-associated components were determined for lipid droplets in lactating cells. Transmission electron-microscopic measurements were made involving 3801 droplets in approximately 211 cells from three rats and 1197 droplets in 66 cells from a mouse. For the purposes of droplet evaluation, cells were divided into seven locations ranging from basal to secreting positions. Droplets were also categorized with respect to contact with other droplets, basolateral plasma membrane, mitochondria, Golgi apparatus, secretory vesicles, and endoplasmic reticulum-cytoplasm (ERC). Data on droplet size showed that droplet growth occurs mainly in the secretory position, confirming previously published findings. Lipid droplets from mouse tissue, although somewhat smaller in size showed similar growth trends to those of the rat. Data on numbers of droplet contacts and percentages of droplet circumferences involved in associations with other cell components showed that the dominant interaction of lipid droplets was with the ERC. However, intimate association of droplets with mitochondria was noted in all cellular locations. In addition, nursed animals exhibited a greater proportion of droplet surface association with secretory vesicles and less in contact with mitochondria in comparison to those not nursed. The significance of these relationships to milk synthesis and secretion is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 236 (1984), S. 249-255 
    ISSN: 1432-0878
    Keywords: Oocyte ; Nucleolus ; Silver staining ; Electron microscopy ; Rat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The nucleoli of dictyate-stage growing oocytes in rat ovaries were examined both with routine electron microscopy and electron microscopy after silver nitrate and ammoniacal silver nitrate (Ag-AS) staining. The nucleoli of the unilaminar follicular oocytes consist of twisted strands of dense fibrillar components, aggregates of granular components, and small fibrillar centers. After Ag-AS staining, silver grains are numerous on the dense fibrillar strands, fewer on the fibrillar centers, and very sporadic on the granular aggregates. The same stainability of three nucleolar components with the Ag-AS method was also confirmed in the nucleoli segregated by actinomycin D. During the transition of growing oocytes from bilaminar to plurilaminar follicle stage, the nucleolar dense fibrillar strands gradually conglomerate and are transformed into large and compact spherules. The stainability of dense fibrillar components with the Ag-AS method was lost along with this nucleolar transformation. These results may provide some new clues on the functional significance of AgAS-positive proteins in the nucleoli.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 235 (1984), S. 51-58 
    ISSN: 1432-0878
    Keywords: Parathyroid glands ; Electron microscopy ; Light microscopy ; Quantitative histology ; Mongolian gerbil
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Stereology and semi-automatic image analysis were used with the aim of comparing the structure of parathyroid glands from untreated adult Mongolian gerbils fixed by immersion with those fixed by perfusion. Subclassification of the chief cells based upon the staining affinity or electron density of the cytoplasm was readily performed only in glands fixed by immersion, and so-called atrophic cells were observed only in these glands. The atrophic cells were often surrounded by “light” chief cells. In glands fixed by perfusion, “light” chief cells were only rarely encountered. A significant difference between glands fixed by immersion and those fixed by perfusion was found only with regard to the form of cells and nuclei, those fixed by perfusion being more spherical. When comparing individual cells within glands fixed by immersion, “light” chief cells were more spherical and had a significantly larger nuclear and cellular size, and a lower mitochondrial volume density than the “intermediate”/“dark” chief cells. Otherwise there were no significant differences in any of the parameters investigated. These data indicate that occurrence of socalled “light” chief cells and atrophic cells is a result of improper fixation. The results of this study do not favour the concept of a functional cycle with a simultaneous occurrence of active and inactive cells within parathyroid glands.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 235 (1984), S. 153-158 
    ISSN: 1432-0878
    Keywords: Bovine ; Interdigitating cell ; Lymphoid tissues ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Electron-microscopic studies of lymphoid tissues from bovine fetuses and from calves disclosed a non-lymphoid cell type in the thymus-dependent zones of secondary lymphoid tissues and in the thymus that is distinguishable from reticulum cells, epithelial and endothelial cells, and macrophages. Based on morphological and topographical criteria, the cell is identified as the interdigitating cell. In addition, studies of the tissues of normal and virus-challenged fetuses, and of conventionally reared calves, indicated that the interdigitating cells originate from monocytoid cells, which undergo differentiation in the thymus-dependent zones during an immune response.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 235 (1984), S. 243-249 
    ISSN: 1432-0878
    Keywords: Gap junction ; Electron microscopy ; Freeze fracture ; Cell-to-cell communication
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Gap junctions exist in the septa between the segments of the lateral giant axons in the ventral nerve cord of the crayfish Procambarus. A large increase in the resistance (uncoupling) of these gap junctions was brought about by mechanical injury to the axonal segments. Both thin sections and freeze-fracture preparations were used to monitor the morphological changes which occurred up to 45 min after injury. There was no apparent change in the organization (a loose polygonal array) of the intramembrane particles which make up the junctional complex up to 45 min after injury. In some instances, however, the intramembrane particles appeared to have moved away from the junctional area. Other junctional regions were internalized and appeared similar to what have been called annular gap junctions. Also at this time (20–25 min after injury), a dense cytoplasmic plug formed in uninjured axon near the junctional region. It is concluded that the gap junctions that exhibit a loose polygonal organization of the intramembrane particles may be either in a state of low resistance (coupled) or a state of high resistance (uncoupled).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1432-0878
    Keywords: Ovulation ; Perfusion ; Graafian follicle (rabbit) ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Ovulation was induced in rabbits by intravenous administration of human chorionic gonadotrophin (HCG), and 4–5 h later the ovaries were isolated and introduced into an in-vitro perfusion system containing synthetic medium with albumin. Rupture of follicles occurred in vitro within the physiological time range (mean 11.3 h after injection of HCG), although with a reduced frequency. Preovulatory and ruptured follicles were studied in detail by light and electron microscopy. In the granulosa layer of ruptured or preovulatory follicles cytoplasmic blebbing activity, disappearance of CallExner bodies and differentiation toward luteinized cells were found. Perhaps the most important sign of normal preovulatory development in vitro was that the basement membrane surrounding the granulosa layer was penetrated by projections of granulosa cells. In the absence of this penetration phenomenon the granulosa layer prolapsed out of the follicle. Immediately before rupture, follicles showed marked degeneration, restricted to the outer layers of the apical wall, which is compatible with the hypothesis that degradative enzymes are released close to the surface of preovulatory follicles. Although the majority of follicles that ovulated under in-vitro conditions showed the same kind of morphological alterations as can be seen in vivo, occasional atypical ruptures occurred without any overt signs during perfusion. Also technical manipulations of the perfusion system, e.g., nonphysiological increase of perfusion pressure, could force follicles to rupture. This illustrates the importance of careful morphological study of all ovaries perfused in vitro before conclusions are drawn.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 237 (1984), S. 149-154 
    ISSN: 1432-0878
    Keywords: Pituitary gland, pars distalis ; Innervation ; Synaptoid contacts ; Electron microscopy ; Rana temporaria L
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary In the pars distalis of the hypophysis of adult Rana temporaria, three types of nerve-fiber profiles were found at two distinct sites, in both lateral parts of the bordering regions of the anterior lobe with the intermediate lobe of the hypophysis. The first type of nerve-fiber profile consists of bundles of very fine axonal elements (diameter: 〈0.7 μm). The second type is formed by larger nerve fibers (diameter up to 4 μm) containing a few neurosecretory granules of approximately 100 nm. The third type of nervefiber profile resembles the second type but these nerve fibers make synaptoid contacts on at least two different types of glandular cells. The possible functional significance of these nerve fibers in the pars distalis is discussed. No nerve fibers were found (1) in the central part of the bordering region of the pars distalis with the intermediate lobe, (2) at the bordering region with the median eminence and (3) with the neurohypophysial stalk, and (4) in all other parts of the pars distalis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 238 (1984), S. 165-175 
    ISSN: 1432-0878
    Keywords: Mesonephros ; Pig embryo ; Glomerulus ; Microvasculature ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Vascularization of the pig mesonephros was investigated in embryos 5–8 cm in length. Vascular injections with microfil were cleared and dissected; corrosion casts were studied under the scanning electron microscope (SEM). Perfusion-fixed tissue was used for SEM and transmission electron microscope (TEM) studies, including freeze-fracture specimens. The branches of one mesonephric artery carry up to 15 glomeruli. Several glomeruli occupy the same arterial branch, with very short afferent arterioles proper. The efferent vessels, frequently 2–5, leave the extensive vascular pole opposite the entering arteriole and split into peritubular capillaries radiating towards the superficial veins. These capillaries form vascular regions in the shape of flattened pyramids. Along its course, one nephron is supplied by vessels derived from 4–7 glomeruli. The nephrons have less vascular contact than in the definitive kidney. The ultrastructure of the single mesonephric vessels matches the metanephric counterparts. Epithelioid cells with renin granules are common in afferent arterioles, larger arteries, and efferent vessels. The lobulated glomeruli are up to 750 μm long and flattened, showing the usual features of podocytes, mesangial cells, and an attenuated endothelium with fenestrations between 50 and 250 μm. It partially retains its own basement membrane. There is no proximal mesangium.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 238 (1984), S. 387-394 
    ISSN: 1432-0878
    Keywords: Pacinian corpuscles, cat ; Denervation ; Atrophy ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The ultrastructure of Pacinian corpuscles of the cat located in the crural region and innervated by the interosseous nerve was studied 1 to 14 months after denervation. Both the Pacinian inner core and capsule remained well preserved one month after denervation. However, the denervated inner cores underwent progressive atrophy and wasting, which resulted in a gradual reduction of the amount of inner-core cells and lamellae, widening of interlamellar clefts, formation of empty spaces in the axial region and a considerable increase in the number of collagen fibrils. In spite of the wasting, the inner core still survived 14 months after denervation, but at least half of its volume became occupied by collagen fibrils which surrounded the remaining inner-core cells and lamellae. Collagen fibrils assembled in the denervated core were markedly thinner than those found in the capsule, as is also the case in normal Pacinian corpuscles. In the capsule, discrete focal degeneration, occasional pyknosis of the innermost capsular cells and macrophage infiltration were observed from the first month after nerve section onward, but the number of capsular layers remained within the normal range (30–40) up to 14 months after denervation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Protoplasma 119 (1984), S. 48-54 
    ISSN: 1615-6102
    Keywords: Electron microscopy ; Marine alga ; Membrane contrast ; Osmium-azole complexes ; X-ray microanalysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary Addition of certain heterocyclic nitrogen-carbon compounds to standard osmium tetroxide solutions used as secondary fixative resulted in an enhanced general membrane contrast in cells of the marine algaEmiliania huxleyi (Lohmann) Kamptner. Ultrastructural cell morphology and the contrast distribution were compared between cells treated according to a standard secondary fixation procedure and cells post-fixed when above mentioned heterocyclic compounds were introduced; in both cases some of the ultrathin sections were post-stained. Different compounds were tested: 1,2,4-triazole (TRA), 3-amino-1,2,4-triazole (A-TRA), 5-amino-tetrazole (A-TEA) and 2,4,6-tri-amino-1,3,5-triazine (melamine). The results were interpreted to indicate the possible bonding types arising from interaction of the heterocyclic compounds with osmium tetroxide and with membrane constituents. Interpretations were partly inspired by considerations from coordination chemistry. All above tests which did not include post-staining of thin sections could be performed at alkaline pH, and consequently calcified structures were preserved. The enhanced osmium accumulation at membranes was verified with X-ray microanalysis, which also showed that in the cases where membranes were visibly contrasted, localization of probable sites of intracellular non-crystalline calcium was facilitated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    ISSN: 1612-1112
    Keywords: Teflon capillary columns ; Chemically modified teflon ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation of teflon capillary columns employing direct coating of the stationary phase to the chemically modified teflon surface and the role of the chemically modified teflon in the separation mechanism are described. Two types of contributions from the modified teflon have been observed: nonspecific adsorption of the carbon surface and specific interactions of polar groups in the carbon skeleton. The use of polar liquid phases can eliminate adsorption due to the presence of polar groups in the modified teflon.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 60-62 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Amines ; Derivatization ; Chloroformate esters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas chromatographic analysis of amines after conversion to electron capture sensitive carbamates in two-phase systems has been studied. Hydrophilic compounds, for instance methylamine, are reacted with 2,2,2-trichloro-tert. butyl chloroformate. Quantitation below 10−7 M can be made by thermionic or electron capture detection. A hydrophobic amine, namely N,N-dimethyl-n-octylamine, was derivatized with 2,4,6-tribromophenyl chloroformate with addition of iodide ion to the aqueous phase. The favorable effect of iodide ion as well as the choice of pH and chloroformate ester is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 98-102 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Rectangular channel ; Efficiency ; Capacity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatographic experiments have been performed in a truly rectangular channel with a 60∶1 cross-sectional aspect ratio, constructed according to the field-flow fractionation technology. It is shown that the peak broadening is controlled by the thickness of the channel while the maximum load is determined by the largest cross-sectional dimension. However, even with its elongated configuration, the side walls contribute significantly to the band broadening of solutes with a high diffusivity. Good agreement is found between the experimental plate height data and the recent theoretical calculations of Golay [13] taking into account the side-wall effect.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Esterification in aqueous solution ; n-Butyl esters of C2−C16 dicarboxylic acids ; Dicarboxylic acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary C2−C16 dicarboxylic acids were esterified in aqueous solution in the presence of sulfuric acid. Esterification in water/n-butanol mixtures with mole ratios between 0.02 and 2.53 can be utilized for the quantitative determination of the dicarboxylic acids by gas chromatography. The presence of water does not interfere at water/n-butanol mole ratios below 0.27. For mole ratios above 0.27 anhydrous sodium sulfate has been used for binding the water. The mole ratio range was 0.25–0.75 for anhydrous sodium sulfate/water, and 0.32–1.3 for sulfuric acid/anhydrous sodium sulfate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 663-667 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Gas solubilities ; Enthalpies of solution ; Polar solutions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas-liquid chromatographic method has been used to determine the solubilities and partial molar enthalpies of solution of the gases H2S, CO2 and COS in four polar solvents. The results agree well with literature values obtained using conventional techniques, with the one exception of H2S in N-methyl-2-pyrrolidinone. In this case there is some evidence for the occurrence of adsorption at the gas-liquid interface.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Esterification in aqueous solution ; n-Butyl esters of aromatic polycarboxylic acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The direct esterification and gas chromatographic analysis of aromatic carboxylic acids as n-butyl esters is described. Derivatization is performed in aqueous solution with n-butanol in the presence of sulfuric acid. The butyl esters of benzoic, phthalic, hemimellitic, trimellitic, trimesic and pyromellitic acids permit their gas chromatographic separation from each other and from fatty acids and alipatic dicarboxylic acids. At mole ratios of [H2O]/ [n-BuOH]≤0.04 the water present does not interfere with the esterification reaction. At mole ratios above 0.04 anhydrous sodium sulfate is used for binding the water, at mole ratios of [Na2SO4 anh.]/[H2O]=0.25–0.75.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 202-204 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Polysiloxane stationary phases ; Heat of adsorption ; Heat of solution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The changes in the heat of solution of polar compounds and xylene isomers in methylsilicone fluid OV-101 deposited on Chromosorb W AW DMCS were studied. It was shown that the heat of solution increases with an increase of the percentage loading of the OV-101 up to 10%. Solution and adsorption thermodynamic characteristics of the studied system are briefly discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Metal complexes ; Chemically bonded phase
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Packings consisting of diphenylphosphine complexes with CoCl2 and CoBr2, chemically bonded to the silica surface, were synthesized and their retention parameters determined. The packings are capable of specifically interacting with electron-donating compounds by forming π-complexes. The interaction is considerably stronger in the case of CoBr2-containing packing than in the case of CoCl2-containing packing.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 234-238 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular columns ; On-column injection ; Stopped-flow operation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple, inexpensive, on-column injector of the septum moving-needle kind is described for quantitative analysis using open-tubular columsn. when operated in the stopped-flow mode an improvement incolumn efficiency is observed combined wit a diminished tendency to produce split-top peaks, particularly for late eluting peaks. Using electronic integration a relative error of about 2.7% was observed for peaks spanning a wide range of sample concentrations and volatilities.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 243-248 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carrier gas ; Viscosity ; Influence of temperature
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The vicosity-temperature relationship of the three gases (helium, nitrogen and hydrogen) most frequenly used as the carrier gas in gas chromatography is studied. Based on available data, equaitions are derived to describe this relationship. Using these equations viscosity data are tabulated for the chromatographically important temperature range.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 260-264 
    ISSN: 1612-1112
    Keywords: Parabens and their dissolution ; Pharmaceutical dosage forms ; Derivatization ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A specific, sensitive and general applicabla gas chromatographic method is described for the determination of parabens in various liquid pharmaceutical preparations: propylparaben and butylparaben in a liquid antacid dosage form (I); methylparaben, ethylparaben and propylparaben in a syrup (II); methylparaben and propylparaben in a solution for injection (III). Each time one of the parabens is used as internal standard. The parabens are extracted with diethylether and derivatized by silylation. Different columns are used for the analysis of the parabens: 3% SE-30 column, a 3% QF-1 column for different selectivity, a 2% OV-1 column for isothermal operation. Special attention is attributed to the standard: the parabens are dissolved in a minimal amount of 0.1 M sodium hydroxide and extracted in the same way as the pharmaceutical dosage form.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Configuration ; Resolution ; Alcohols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The study of the resolution of sixteen secondary aliphatic alcohols by gas chromatography on (+)-dodecyl (2R, 3R)-tartrate, trapping the ascending part of the peak from a conventional filled column, has allowed the determination in a single operation of the sign and order of emergence of enantiomers. A correlation between the configuration of these secondary alcohols and their order of emergence has been established.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 309-312 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carboxylic acids ; Acetonyl derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation of the acetonyl esters of nine aliphatic carboxylic acids is described, the general formula of the derivatives being RCOOCH2COCH3 where R=alkyl or H. The derivatives show good chromatographic properties on both packed and capillary columns. The electron impact and chemical ionisation mass spectra of the derivatives are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Thermodynamic relationships ; Retention index ; Peak identification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A thermodynamic criterion, ΔQ, is suggested which permits to estimate the difference in the functional group energy of interactions for two different stationary phases. The linear dependence of ΔQ on the homolog number m of any series Rm X can be used as the thermodynamic criterion for the identification of substances by GC analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 477-488 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open tubular (capillary) columns ; Sample capacity ; Column comparison ; Film thickness ; Column diameter
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Wall-coated, open-tubular (capillary) columns prepared from different diameter tubing, with different liquid phase film thickness, are compared with each other and with packed and support-coated open-tubular columns. The comparison is based on the variation of the phase ratio and the capacity factor, and includes column efficiency (HETP, theoretical plate number), resolution, retention time, and sample capacity. Problems associated with the evaluation of the sample capacity are outlined. The influence of temperature on column performance is discussed in detail. Finally, the possibilities of short, wide-bore open-tubular columns prepared with a thick liquid-phase film are demonstrated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Protoplasma 111 (1982), S. 206-214 
    ISSN: 1615-6102
    Keywords: Bark beetle ; Sensilla ; Chemoreceptors ; Mechanoreceptors ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary The antennal sensilla inI. typographus are almost exclusively confined to the flattened terminal flagellar segment. The sensillar types have distinct distribution patterns in the three areas where they are found. Judging from the ultrastructural characteristics the following functions can be assigned to the sensillar types: chemoreception, single-walled and double-walled sensilla; chemoreception/mechanoreception, terminal-pore sensillum. Moreover there are two types of mechanoreceptors, one of which is connected to a bristle, whereas the other terminates within the cuticle of the flagellar segment.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Springer
    Plant and soil 76 (1984), S. 127-137 
    ISSN: 1573-5036
    Keywords: Adenylate pool ; Biomass volume ; CO2 evolution ; Chitin ; DNA ; Electron microscopy ; Enzymes ; Fluorescent antibody ; Fumigation-respiration ; Fungi Histochemistry ; Imunofluorecence ; Jones-Mollison technique ; Microcosms ; Monoclonal antibodies ; Nitrogen ; Nutrients ; Oxygen consumption ; Phosphorus ; Phytotoxins ; Plate counts ; Rhizobium ; Rhizosphere ; Sulphur ; Xenobiotics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Summary There is an immense literature on biological and biochemical analyses of soils. Such analyses have revealed the enormous richness of species in soil and their vast range of metabolic potentials and ecological diversity. Accordingly, the approaches used to investigate the soil biota and its biochemistry usually have to be modified or adapted depending upon the purpose of the investigation. Studies of micro-organisms in the soil environment, are complicated because microbial cells are commonly attached to surfaces where they live side-by-side with other populations in consortia usually containing different morphological and physiological types. Such assemblages of organisms cannot be described quantitatively using cultural techniques, such as plate counts, which underestimate both cell numbers and viable biomass. The development of more powerful observational and staining techniques has improved our knowledge of the diverse morphological and biochemical composition of soil micro-communities. Such findings have been amplified at a grosser level by laboratory studies with multi-component systems (microcosms) to mimic field situations and to assess the range of biochemical potentials of microbial consortia. But despite notable advances in analytical methods we are still, with a few exceptions, unable to detect or identify those microorganisms which carry out specific biochemical transformations or determine whether particular cells are alive, dormant or dead at the time of observation. Considerable work has been done to define some of the fundamental ecological attributes of microbial assemblages in soil. Productive work on the metabolic activities of the soil microbiota, specially geochemical transformations of C, N, S and P, has been under way for more than a century. But only in more recent years have more sensitive and reproducible analytical methods become available to measure viable biomass in soil. This will enable some insight to be gained into the role that microbial biomass plays as a labile source and sink for plant nutrients.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Springer
    Plant and soil 76 (1984), S. 319-337 
    ISSN: 1573-5036
    Keywords: Aggregates ; Aluminium ; Bacterial mucilage ; Binding agents ; Calcium ; Cation bridges ; Complexing agents ; Dispersion ; Electron microscopy ; Electrophoretic mobility ; Fungal hyphae ; Glues Iron ; Management Periodate ; Polysaccharides ; Rhizosphere ; Roots ; Slaking
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Summary The stability of pores and particles is essential for optimum growth of plants. Two categories of aggregates macro- (〉 250 μm) and micro- (〈250 μm) depend on organic matter for stability against disruptive forces caused by rapid wetting. Dispersion of clay particles from microaggregates is promoted by adsorption of complexing organic acids which increase the negative charge on clays. The acids are produced by plants, bacteria and fungi. However, the dispersibility of clay in microaggregates is offset by the binding action of polysaccharides, mainly mucilages produced by bacteria, but also by plant roots and fungal hyphae. The stability of microaggregates is also enhanced by multivalent cations which act as bridges between organic colloids and clays. Macroaggregates are enmeshed by plant roots, both living and decomposing, and are thus sensitive to management, and increase in number when grasses are grown and the soil is not disturbed. Lack of root growth,i.e. fallow, has the opposite effect. Various implications for management of soil structure are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 226 (1982), S. 589-608 
    ISSN: 1432-0878
    Keywords: Kidney (frog) ; Glomerulus ; Nephron ; Tight junctions ; Freeze-fracturing ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary By the use of thin sections and freeze-fracture replicas the glomerular and tubular structures of the kidney of the frog (Rana esculenta) were studied with special reference to intercellular junctions. In the glomerulus the filtration barrier is of very variable thickness, and frequent tight and gap junctional contacts occur between podocyte processes. Although structurally less elaborate, the proximal tubule resembles its mammalian counterpart. In the initial part the tight junctions are relatively shallow but become very broad in the mid and distal portions of the proximal tubule. The proximal tubular cells are extensively linked by gap junctions. In some animals the shapes of the cells in the proximal and distal portions of the proximal tubule were markedly different. The distal tubule consists of two segments which differ mainly in the pattern of interdigitations and the structure of the zonulae occludentes. Similarities with the tight junctional morphology of the mammalian distal tubule are striking. In the first part of the distal tubule (diluting segment) a narrow band of parallel tight junctions is found closely resembling that found in the mammalian straight distal tubule; in the more distal part of the distal tubule, however, a broad band of anastomosing tight junctional strands exists, like the zonula occludens of the mammalian convoluted distal tubule. The connecting tubule displays cellular dimorphism: its wall contains a mixture of light and dark (flask) cells. The luminal and basolateral membranes of the flask cells are covered with numerous rod-shaped particles. The tight junctions of the connecting tubule are broad and increase in depth and number of strands along its length; they are typical of a very tight epithelium. In spite of several dissimilarities with phylogenetically younger kidneys our findings suggest that many structural principles of the mammalian kidney are also represented in the kidneys of amphibians. The structural-functional relationships are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 704-706 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Isopropyliden-sorboses ; TMS-derivatives ; GC-MS combined technique ; Mass spectra
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method has been developed using gas chromatography — electron impact mass spectrometry for the determination of the di-0-isopropylidene-sorbofuranose and mono-0-isopropylidene-sorbofuranose. The compounds are separated as their trimethylsilyl derivatives on a capillary column coated with the stationary phase SE-52. The mass spectra show that the silylation reaction is quantitiative and that the isopropylidene groups does not change.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 183-185 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Analysis of ethylbenzene hydroperoxide ; Time normalization method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatographic method, based on the time normalization technique, is described for the analysis of ethylbenzene hydroperoxide in mixtures containing ethylbenzene, acetophenone, 1-phenylethanol, benzaldehyde and phenol. Different liquid phases were tested and the best results were obtained with tricresyl phosphate and neopentyl glycol sebacate. The influence of the support, the liquid loading and the gas velocity are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 625-630 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Comparison of liquid phases ; Influence of temperature ; Retention index data
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The influence of temperature and liquid phase film thickness of open-tubular (capillary) columns on the retention index values of hydrocarbons on methylsilicone liquid phases is discussed. Data obtained on methylsilicones and squalane are compared. Retention index values of 43 hydrocarbons between 40 and 70 °C on OV-101 liquid phase are listed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 351-354 
    ISSN: 1612-1112
    Keywords: Supported catalysts ; Reserved-flow GC ; Drying step ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Application of reversed-flow gas chromatography to study the drying step in the preparation of supported catalysts is proposed. It is demonstrated that this technique can be applied to investigate the kinetic law followed, as well as to obtain kinetic parameters of drying (rate constants, activation energies and frequency factors). Amaterial illustrating this application is γ-Al2O3 impregnated with usual organic solvents (n-C5H12,n-C6H14,n-C7H16, CH3COCH3 and CH3CH2OH). It was found that in all cases above a simple first-order law based onone kind of active site is followed. Moreover, it was observed that the activation energyE a of the drying process increases almost linearly with the relative molecular mass of the solvent, whereas for the same solventE a increases with the amount used. The operation of a kinetic compensation effect suggests “similar” activated complexes of the various solvents used.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Fused silica capillaries ; New polar phases: OV-1701 and RSL-310 ; Immobilization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The possibilities of OV-1701 and RSL-310, two new stationary phases, have been evaluated for capillary gas chromatography in fused silica columns. OV-1701 is a cyanopropylphenyldimethyl polysiloxane of moderate polarity possessing excellent chromatographic characteristics. The phase exhibits high coating and chromatographic efficiencies, high temperature stability and is suitable for cross-linking. RSL-310 is a polar liquid stationary phase yet to be permanently bonded in a capillary column. The selectivity of both phases extends the applicability of fused silica columns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 241-244 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Monosaccharides ; Polyols ; GC of TMS derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper describes the gas chromatographic separation of the mixture of isopropylidene monosaccharides, and their trimethylsilyl derivatives. Based on the total analysis time and resolution the best stationary phase was SF-96 using Chromosorb G as the solid support and temperature programming.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 312-314 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Injection-port modification ; Oxygen and nitrogen traces
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The paper presents a new device modifying normal injection port of a gas chromatograph for eliminating air contamination thus enabling determination of traces of oxygen or nitrogen. Further modification is also proposed which enables the analysis to be carried out with a limited quantity of sample gas. Potential application of this device in the analysis of reactive gases like florine has been indicated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    ISSN: 1612-1112
    Keywords: Phthalides ; Gas chromatography ; Chromosorb W ; Isomerization ; Ligustilide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary During GLC of naturally occurring mixtures of phthalides on packed columns an artefact was sometimes detected that originated from Z-ligustilide. Active sites of Chromosorb W were responsible for the formation of the artefact, that was assumed to be E-ligustilide as GC-MS revealed that its mass spectrum was identical with that of Z-ligustilide. No isomerization was observed when freshly coated Chromosorb W was used or the support was deactivated by benzoyl chloride or melamine. The identity of the artefact was confirmed by UV irradiation experiments.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 30-32 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Arsenic ; Inorganic materials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the quantitative chlorination and extraction of arsenic as arsenic trichloride from a number of alloys. The conditions for the quantitative gas chromatographic measurement of the volatile chloride have been studied. The proposed method for inorganic materials is very fast giving results within 10 min; sensitive, 1.5·10−13 g As can be detected, simple and accurate. At the ng level of As the error is about 20% with a standard deviation less than 20%, and at the 10pg level the error is about 36% with a standard deviation of 44%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 765-768 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Preparative scale chromatography ; Capacity ; Dual-stage separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The capacity of different versions of single- and dual-stage separation of mixtures on a preparative scale is considered. It has been shown that dual-stage separation with intermediate condensation considerably enhances the capacity of the installation as compared with a single-stage process.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 117-124 
    ISSN: 1612-1112
    Keywords: Various packed GC column ; Gas chromatography ; Porous layer beads ; GC/MS analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Theoretical comparisons of various packed GC column types are presented with respect to analysis time, efficiency, sample dilution, and sample capacity for a given maximum inlet pressure. In particular, totally porous particles, porous layer beads, and glass beads are compared with one another. It is shown that 30 μm porous layer beads offer a useful compromise between analysis time and plate count with relatively good sample capacity. Moreover, when using 1 mm i.d. columns (microbore), outlet flow rates that are reasonable for direct coupling to magnetic sector mass spectrometers are achieved making these columns suitable for GC/MS. Using 30 μm Zipax porous layer beads, columns yielding 8,000 to 10,000 plates/meter have been produced with inlet pressures of 13 to 26 atm. A simple modification of the injection port converts the maximum inlet pressure of a commercial gas chromatograph to 26 atm. With such pressures, columns in excess of 20,000 plates can be achieved. Chromatograms are presented illustrating the promise of these microbore columns for GC and GC/MS analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 245-248 
    ISSN: 1612-1112
    Keywords: Chromatoscopy ; Gas chromatography ; Graphitized carbon black ; Molecular structure and retention ; Aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A molecular-statistical calculation of the retention volumes at zero sample size on graphitized thermal carbon black is carried out for quasi-rigid molecules of fluorene, indene, 1-methylindene, 2-methylindene and three dimethylindenes. A reasonable agreement is observed between the calculated and the available experimental gas chromatographic data. The potential barrier to internal rotation and the torsional angle in styrene molecules are estimated by comparing theoretically calculated and measured retention volumes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Silicone liquid phases ; Oxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The on-column oxidation of apolar and polar silicones used as gas chromatographic stationary phases is investigated. Even at 225° the effects of oxidation are found to be slight. Of the materials investigated the methylphenylsilicones are the most stable.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    ISSN: 1612-1112
    Keywords: Glass capillary ; Gas chromatography ; Methyl chloroacetates ; Methyl chloropropanoates ; Methyl chlorobutanoates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas chromatography of all chlorinated methyl acetates, methyl propanoates and methyl mono- and dichlorobutanoates has been studied on Carbowax 20M and SE-30 glass capillary columns under various running conditions. The order of elution on a non-polar column was largely determined by the boiling point of esters, whereas on a polar column it was much influenced by the structure of compounds. Complete separation of the combined mixture of all 27 compounds could not be achieved, however, methyl 3,3-dichlorobutanoate was the only ester overlapped on both columns in spite of the various column temperatures used. The best separation of the mixture was on Carbowax 20M with a temperature program from 50°C at 8°C/min, isothermal running conditions leading either to poor separation of volatile components or long analysis time and broad peaks of higher chlorinated esters. The relative retention times for compounds at the various column temperatures are given and the retention order on a polar and on a non-polar column discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 517-520 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carbon-silica adsorbents ; n-Octadecanol film ; Phase transitions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The properties of the n-octadecanol film on carbon-silica adsorbent (Carbosil) were investigated. It was found that n-octadecanol forms an oriented film on the Carbosil's surface. If the surface of the basic silica gel is not completely covered with carbon, then the phase transition takes place in this film at a temperature higher than the melting temperature of n-octadecanol. One may distinguish two forms of this film, characterised by the different structures and the temperatures of the phase transitions. The first exists on the surface of silica gel unblocked by carbon. This part of the film is a monolayer, in which the alcohol molecules are vertically oriented. The solid compact-liquid expanded type phase transition at the well-defined temperature occurs in this film. In the second part of the film formed on the carbon surface, there is a multilayer of n-octadecanol. Its molecules are probably parallely oriented in relationship to the adsorbent surface. This film desintegrates progressively when the temperature increase. Maximum temperature of this phase transition is lower than the temperature of its analogue on pure silica gel surface.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 546-558 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Quantitative analysis ; Sample inlet systems ; High-speed analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The attainment of precise quatitative analytical data using open-tubular (capillary) columns in standard, commercially available gas chromatographic instrumentation is demonstrated. Key elements in the design and proper utilization of the instrumentation are discussed. The function of the various sample introduction systems is elaborated and their quantitative performance demonstrated. The extra-column contribution to band-spreading is determined and the resultant data is used assessing the suitability of commercial instrumentation for highspeed capillary gas chromatography. The quantitative analysis of a sample containing some eleven components in less than thirty seconds is shown.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Crystal hydrates as stationary phases ; Mobile Phases containing water ; Selective retentions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of crystallohydrates, crystallohydrate solutions and melts as stationary phases in gas chromatography has been proposed. Crystallohydrates have been shown to display high selectivity in the separation of polar organic compounds when use is made of water vapours as the mobile phase. Some aspects of gas-liquid chromatography in water vapours and with the stationary phase comprising crystallohydrates have been studied, and the preliminary results obtained point to the desirability of further progress in this field.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 201-203 
    ISSN: 1612-1112
    Keywords: Phenols ; Whisky ; Gas chromatography ; Aroma compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Twelve volatile phenols were identified in whisky by combined gas chromatography-mass spectrometry. Of these phenols 2,4-dimethylphenol was found for the first time in the aroma of whisky. The content of phenol, o-, m-, and p-cresol, guaiacol, p-ethylphenol, p-ethylguaiacol and eugenol in whiskies originating from different countries was determined by gas chromatography as their 2,4-dinitrophenyl ethers using electron capture detection. The results show that Scotch whiskies differ from others in the content of o-, m-, and p-cresol. The odour threshold values of phenols studied were determined in a 10% (v/v) ethanol-water mixture and in some cases also in the whiskies. Cresols have been found to make contribution to the aroma of Scotch whisky.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 26-31 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Ionization detectors ; Gaia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper is an account of the development of the gaia hypothesis as seen through the eyes of a gas chromatographer. Gaia is a radical notion about the Earth which postulates the climate and chemical composition to be regulated at an optimum by and for life. Gas chromatography played an important role in the gathering of evidence for the hypothesis but most significantly the art of inventing detectors lead to the developement of a planetary life detector through which gaia was revealed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 282-285 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Naphtha analysis ; Gasoline analysis ; Hydrocarbon type analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two different gas chromatographic methods are used for the determination of hydrocarbon type distribution in naphtha and gasoline samples with final boiling points up to 275 °C. The methods are based either on a single capillary column or on a valve-switched packed column system. Both methods give extensive information on paraffins, olefins, naphthenes and aromatics in total as well as by carbon-number. In each case the analysis is fully automated with a computer controlling the entire analysis from injection to results presentation. The advantages and limitations of both methods are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 322-324 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Graphitized carbon black supports ; Determination of hydroxyacids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Acid-washed graphitized carbon black (Carbopakc B) modified with trimesic adic and PEG 20M has proved to be effective for quantitative analysis of underivatized low molecular weight hydroxyacids. Calibration data revealed good linear relationships between relative peak area and concentration for lactic and 3-hydroxybutyric acids down to 0.05 mmol/l. The packing material was suitable for the analysis of aqueous solutions of hydroxyacids as it is tolerant to injections of water over a prolonged period of use. The GC system developed has been applied to the analysis of some hydroxyacids of biomedical interest in blood plasma and lactic acid contained in wine and beer.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Modified thermal energy analyzer ; Selective detection of nitrogen compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modification to the TEATM Analyzer is described, which allows it to be used as a highly selective GC detector for nitrogen compounds as well as for N-nitrosamines and nitro compounds. The modified Analyzer is as sensitive as the AFID, but has a much higher selectivity towards nitrogen compounds than the AFID. Its response appears to be molar, with an output that is dependent only on the number of nitrogen atoms present. The performance of the modified Analyzer for the analysis of ammonia, amines,N-nitrosamines, nitriles and organonitro compounds is reported and discussed, as is its application to the detection of these compounds in bacon and beer samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 367-368 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open tubular (capillary) columns ; Variation of film thickness ; Thick-film columns ; Mass transfer terms
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The factors characterizing the influence of the variation of the liquid phase film thickness on the mass transfer terms in the Golay equations describing the performance of open tubular columns are investigated and numerical values are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    ISSN: 1612-1112
    Keywords: Graphizized carbon black traps ; Organic air pollutants ; Work areas ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of traps containing graphitized carbon black for the collection and pre-analysis of atmospheric pollutants in industrial areas is presented. The working conditions, in terms of trapping capability and effectiveness of release by thermal desorption are discussed. Some practical applications are also given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Van der Waals' volume ; Polarity of stationary phase ; Retention index
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Equations for Retention Index (I) versus Van der Waals, volume (Vw) on squalane are studied for alcohols, carbonyls, esters and ethers. Each equation includes linear and branching substances with different positions of the functional group in the carbon chain. The study is extended to stationary phases with polarities from 4.29 to 91.54 on the Tarjan et al. scale. Variations of the slope and origin ordinate values with the polarity of the stationary phase are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 125-132 
    ISSN: 1612-1112
    Keywords: Capillary columns ; Fast analysis ; Gas chromatography ; Instrumental effects ; Optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The efficiency of fast GC columns depends largely on the quality of the chromatograph. A theoretical and experimental study shows the relative importance of the various phenomena involved and permits the optimization of a GC System. Extremely good performances, exceeding 2,500 plates per second have been routinely obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 180-182 
    ISSN: 1612-1112
    Keywords: Acidic fermentation products ; Characterisation ; Gas chromatography ; Methyl esters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid and simple method for the identification of acidic fermentation products is described. Methyl esters of volatile and non-volatile acids are separated on a single chromatographic column. Retention time data for a number of acids are tabulated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 521-524 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Connectivity index ; Van der Waals' volume ; Alkanes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The relationships between retention index and Van der Waals' volume and between retention index and connectivity index have been studied for 58 different alkanes (C1−C9) on squalane. The correlation coefficient for the former is higher than for the latter. From these equations a linear relationship between Van der Waals' volume and connectivity index is obtained which indicates that the two parameters are equivalent. A simple method for calculating the Van der Waals' volume of alkanes is proposed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Fused silica capillaries ; Capillary drawing ; Glass capillaries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A compact description is given of a simple and reliable method of drawing flexible fused silica capillary for gas chromatography. Some emphasis is given to the fact that the practices of drawing optical fibres should not be followed too slavishly so this leads to unnecessarily complicated and expensive equipment. Satisfactory capillary column silica tubing can be made with straightfoward extension of the method developed earlier for drawing thick walled capillary. A simple glass/silica hydrogen oxygen diffusion flame bumer is described for fusing the preform tubing at the draw point which is enclosed by a water cooled glass enclosure to trap evaporated silica and maintain the operation under dust free conditions. The uniformity of the capillary diameter is better than 5% which is adequate for most gas chromatographic purposes. The second part of the paper yet to be published will cover the methods developed for coating the capillary both internally and externally.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 107-111 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Thermionic ionization ; Catalytic flame ionization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A newly designed thermionic detector was operated in two modes of thermionic ionization detection (TID), and a third mode of catalytic flame ionization detection (CFID). Operating modes were varied by changing the composition of the electrically-heated thermionic/catalytic source, and the composition of gases supplied to the detector. A TID-2 source activated by a low concentration of Cs/ceramic was operated in a dilute H2/air environment and provided specific responses to nitrogen and phosphorus compounds. A TID-1 source activated by a high concentration of Cs/ceramic was operated in a N2 environment and provided very high specificities and picogram detectivities to compounds containing electronegative functional groups such as the NO2 group. A CFID source formed from Ni/ceramic was operated in a H2/air flame environment and provided universal responses to all organics with enhanced responses to some heteroatom compounds.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Cross-linked Stationary phase ; Immobilized Stationary phase ; Packed columns ; Trapping
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A coating of silicone SE-54 on Chromosorb W has been converted to an analytically stable, immobilized stationary phase layer by cross-linking with an organic peroxide. Up to 10% by weight has been applied in this manner. Excellent high temperature qualities are exhibited, such as low bleeding and good base line stability, during typical analyses. Poly (2,6-dimethyl-p-phenylene oxide) has also been crosslinked as a surface coating on Chromosorb W with an organic peroxide. From 3 to 4% by weight has been immobilized in this way. The resultant packing material, following high temperature conditioning, has been examined for use as an adsorbent of trace substances, similar to the applications to which such adsorbents as Tenax GC have commonly been applied, e.g. trace analysis of air. It appears to exhibit satisfactory properties for this analytical purpose.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 21-22 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Isopropylidene-glucose ; Glucose ; GC of TMS-derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper describes the gas chromatographic separation of the mixture of di- and mono-O-isopropylidene-D-glucose and D-glucose as their trimethylsilyl derivatives. The use of OV-101 as liquid phase provides a complete separation for the all components in the mixture. Quantative analysis was performed using xylitol as the internal standard for di- and mono-O-isopropylidene-D-glucose, and sorbitol as the internal standard for α-and β-glucose.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Nuclear magnetic resonance ; Terpenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure is described for recording1H NMR spectra of flowing gaseous GC fractions boiling as high as 200°C. The line width of the signals in the NMR spectra is smaller than 2.2Hz.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 556-559 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid chromatography ; Tetramethrin ; Residues
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the analysis of tetramethrin aqueous formulation and residues of tetramethrin on woolen cloth. The samples were extracted with acetonitrile and partitioned with benzene. Interferences were removed by liquid column chromatography with acid alumina and eluted with 10% ethyl acetate-hexane. Analysis was by gas chromatography with a 10% UCW98 (methylsilicone) column. Detection was made with the flame ionization detector to avoid the repeated dilutions necessary with use of the electron capture detector.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Electric parameters ; Physico-chemical relationships ; Structure-retention study
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new equation is derived relating the retention index to the molecular polarizabilities, ionization potentials and permanent dipole moments of the stationary phase and the solute. Various implications of this equation to quantitative structure-retention relationships are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    ISSN: 1612-1112
    Keywords: Aldehydes and ketones ; 2,4-dinitrophenylhydrazine-coated silica gel ; Gas chromatography ; Column liquid chromatography ; Pollution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary After a brief review of several methods described in the literature this paper discusses air-sampling on 2,4-dinitrophenylhydrazine-coated silica gel and identification requirements for aldehydes and ketones most commonly found in industrial pollution. Quantitative analysis of formaldehyde and acetaldehyde either by GC or by HPLC techniques is established using a dynamic system producing test atmospheres and compared with the usual colorimetric determinations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 382-384 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Trapping by active charcoal ; Thermal desorption system ; Microwave oven ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 140-141 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Narcotics: street samples ; Narcotics, adulterants and diluents: simultaneous determination ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 274-276 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, glass ; Liquid-liquid and liquid-solid extraction ; Serum lipids ; Fatty acids ; Cholesterol and cholesteryl esters ; Triglycerides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 280-281 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Reaction GC ; Iodination reactor ; Electron capture detection ; Trace analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 477-479 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Glass capillary column ; Adsorbent ; Cold trapping ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed and capillary columns ; Fungicides and insecticides ; Adsorption ; Length of column ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 536-537 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; On-Column injection ; Vaporizing injection ; Decomposition ; α-Ferrocenyl carbinols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 504-508 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; GC/MS/DS ; Cryotrapping and cryofocussing of organics ; Purgeable compound analysis ; Trace organic analysis ; Priority pollutants ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The purge and trap (P&T) method of analysis has been interfaced with fused silica capillary column gas chromatography. This interfacing has been accomplished without splitting the P&T trap desorption carrier gas. Thus, 100% of the purged compounds are transferred to the column. The analytes are cryofocussed on the column using whole column cryotrapping (WCC) at -80°C. The resulting P&T/WCC procedure is extremely well-suited to the analysis of trace purgeable aqueous organic compounds. Samples and standards containing a variety of aromatic standard compounds were analyzed. The standards included benzene, toluene, ethylbenzene, xylenes, C3-C4-benzenes, and naphthalene, as well as three P&T internal standard compounds. Chromatographic peak widths were uniformly less than 6 s at the base and excellent precision was obtained in the relative retention time data for all compounds. The chromatogram of a groundwater sample contaminated with aromatic gasoline compounds is also presented. Since P&T/WCC works well with fused silica capillary columns, the full sensitivity and chromatographic efficiency of capillary gas chromatography is made available to P&T analyses.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 542-544 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica (capillary) columns ; Bonded (cross-linked) phases ; Hydrocarbon analysis ; Olefinic hydrocarbons ; Retention index data ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 50-51 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass, fused silica ; Connection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Effluent splitter ; Selective detectors: NPD, Hall™ electrolytic conductivity detector ; Chloro- and chloronitroanilines ; POTW sludge extracts ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Simultaneous detection with a 700-A Hall™ and an NPD detector is an effective technique for characterizing chloro-and chloronitroanilines in highly complex Publicly Owned Water Treatment Works (POTW) sludges. The utilization of a modified Varian effluent splitter and a SE-54 fused silica capillary column permitted the detection of mid-picogram quantities of the polar chloroanilines without sacrificing peak shape. The response of the Hall™ detector in the halogen mode was roughly proportional to the number of chlorine atoms present, while the response of the Hall™ in the nitrogen mode and the NPD was less predictably influenced by the presence of one or more nitro groups. When combined with retention time data, the ratio of the NPD response to the Hall™ response has been found to substantiate the presence of chloro- and chloronitroanilines in sludge extracts.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 98-99 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Polyaromatic hydrocarbons ; Airborn Particulates ; Aircraft turbines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; High temperature silylation ; C2-C6 fatty acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 206-207 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; cis, trans, positional isomers of C22 esters separated on OV-73 ; Numerous arguments favor nonpolar columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 236-244 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Rotary valve ; Cold trap ; Reinjection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper describes a cold trap/reinjection system for capillary columns which utilizes a flow switching rotary valve. Sample enrichment is performed in a liquid nitrogen-cooled glass trap attached to the valve. Evaporation of enriched compounds is carried out with the aid of an electric heating coil. Parameters such as cryogenic trapping efficiency, reinjection rates, transference of sample, and adsorption, as well as overall performance, are examined. In addition, a comparison is made between the cold trap/reinjection technique and injection with a gas-tight syringe.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 265-266 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Helium ionization detector ; Aroma ; Coffee ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 45-47 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Fast screening of drugs and adulterants ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 55-56 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Non-uniformity of distribution of stationary phase confirmed ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 53-55 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Thermal aging regeneration of fused silica capillaries ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; SD-E enrichment ; Pesticide residues ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simple method is described for the quantitative determination of organochlorine pesticides and polychlorinated biphenyls (PCB's) in water at the sub-ppb level. A micro gas-phase extractor advantageously replaces other preconcentration and purification techniques. The extract is analyzed by capillary gas chromatography without further enrichment. The recovery at the ppb level was nearly 100% for organochlorine pesticides and more than 80% for PCB's. The complete procedure including sample preparation, steam distillation-extraction, and capillary gas chromatographic analysis is carried out in less than four hours.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 377-378 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Glass capillary columns ; Headspace analysis ; Alcohols in blood ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...