ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Books
  • Articles  (819)
  • Data
  • Chemistry  (819)
  • Wiley-Blackwell  (819)
  • American Institute of Physics (AIP)
  • 2010-2014
  • 1995-1999  (352)
  • 1980-1984  (309)
  • 1975-1979  (158)
  • 1935-1939
  • 1925-1929
  • 2013
  • 1997  (352)
  • 1984  (170)
  • 1983  (139)
  • 1978  (78)
  • 1977  (80)
  • 1925
  • Medicine  (819)
Collection
  • Books
  • Articles  (819)
  • Data
Publisher
Years
  • 2010-2014
  • 1995-1999  (352)
  • 1980-1984  (309)
  • 1975-1979  (158)
  • 1935-1939
  • +
Year
  • 1
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Efforts to explain blood compatibility with synthetic and natural surfaces based on a single parameter or a single biological test procedure have either been unsuccessful or led to misleading generalizations. The problem reflects the complex interdependence between material's properties, the composition and properties of blood, and in vivo biorheological conditions. Among the initial events that occur when materials contact blood is the very rapid adsorption of plasma proteins; this process effectively influences the subsequent interactions with the formed blood elements, especially the platelets with the proteinated surfaces.In the case of natural surfaces, when the endothelium is damaged, collagen may become exposed that may cause the activation, adhesion, and aggregation of platelets leading to thrombosis. Current evidence indicates that the platelet-aggregating ability of collagen depends on its “multimeric” or fibrillar structure, rather than on the activation of the platelet-bound enzyme system. Under normal conditions, the flowing blood is probably not in direct contact with endothelial cells that line the blood vessel walls, but with an adsorbed layer of plasma proteins. Should a formation of a multilayer of plasma proteins occur following the initial adsorption of a monolayer, this process could be influenced by changes in the solubility of the proteins, especially fibrinogen, the solubility of which is quite low in plasma. The hypothesis is proposed that such changes may be intimately related to the electrical properties of proteins present in the vascular wall and in blood. It is possible that these properties play a much greater role in thrombogenesis and in the problem of blood compatibility than is currently appreciated.Considering synthetic polymers, a number of these have been prepared that exhibit little adverse effects on blood components and, at the same time, retain their physical properties for various periods of time in the physiological environment. These combined biological and physical properties make them useful for various prosthetic and other biomedical applications in surgery and therapy.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 111-123 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The enzymatic activity of α-chymotrypsin (CT), immobilized on hydrogelcoated polymer film supports, has been investigated. The support was prepared by radiation-graft copolymerization of 2-hydroxyethyl methacrylate (HEMA) and methacrylic acid (MAAc) on silicone rubber films. The enzyme was covalently coupled to the carboxylic group of MAAc via the N-hydroxysuccinimide (NHS) ester active intermediate.Increasing MAAc contents of the hydrogel resulted in increased attachment of CT. The integrity of the CT active site after attachment was assessed by an active site titration with diisopropyl fluorophosphate (DFP). As the MAAc content of the hydrogel was increased, an increasing fraction of the attached CT retained its activity to DFP. A greater fraction of CT was active towards DFP when adsorbed than when coupled.The rates of hydrolysis of some synthetic model substrates by the immobilized CT were also measured. The negative charge on the hydrogel had a large effect on the rates of these hydrolyses. The pH optimum for the hydrolysis of N-acetyl-L-tyrosine ethyl ester (ATEE) by immobilized CT was higher than that of free CT. Increasing MAAc content of the hydrogel resulted in larger shifts in the pH optimum. The maximum rates of ATEE hydroylsis per mg CT declined sharply with increasing MAAc content of the hydrogel. This is probably related to the increasing repulsive force between the ATEE (negatively charged above ⋍ pH 9.5) and the hydrogel with increasing MAAc content. The activity of immobilized CT to ATEE is small compared to that of free CT, partly due to this charge effect. Conversely, the rate of hydrolysis of BAEE, a positively charged substrate, by immobilized CT at pH 11, is almost fourfold greater than that by free CT at its pH optimum.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 187-193 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A single application of fluoride to the epiphysis of the femur induced accelerated bone formation. The additional bone gave rise to a stability effect on the implant inserted in the femur as expressed by an increased dislodgement force required.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A percutaneous implant for the attachment of an artificial limb has been designed and tested in 14 pigs. Firm fixation to beone was achieved with the porous-surface layered metal intramedullary stem design in some cases. Dacron velour was used at the soft tissue interface. Evidence of soft tissue ingrowth was seen. However, the velour was unable to maintain adequate epithelial adhesion to form an anatomical seal and a barrier to bacteria.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 83-87 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The purpose of this report is to present our 5-year experience in reconstructing large bony defects in the cranial vault of 16 patients. The method employs an alloplastic implant device made of elastomer-coated cloth mesh, used in conjunction with bone grafting [D. L. Leake and M. Habal, J. Biomed. Mater. Res., 10, 555 (1976)]. The cranial defects ranged in size from 6 × 6 cm to 15 × 17 cm. The defects were in the frontal, temporoparietal, and occipital regions. Particularly challenging was the frontal-orbital region involving the superciliary ridges. The alloplastic implant provides controlled contour of the bone graft material while providing strength and stability during healing. The implant has adequate but not complete rigidity, allowing adaptability in the operating room. The elastomer used is a polyetherurethane. Any biocompatible cloth mesh can be used, but Dacron [poly(ethylene terephthalate)] was chosen because of its extensive implant history.Contrasted with reconstruction using only bone, where as many as half of the cases had uneveness and were found to be aesthetically unsatisfactory, the technique described here has resulted in aesthetically excellent results and an intact neurocranium in the 16 patients studied thus far.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 149-165 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A new adhesive fissure sealant, which consists of a solution of 3% 2-hydroxy-3-β-naphthoxypropyl methacrylate in methyl methacrylate (MMA), poly-MMA powder and an oxidized tri-n-butyl borane, a polymerization initiator, was developed. Tensile bond strength between an acid-etched bovine enamel and a poly-MMA bar joined by this sealant was 60 kg/cm2, and the value did not decrease much after 30 days immersion in water at 37°C. Penetration of fuchsin into the sealant-enamel interface during a percolation test was not observed. SEM observation showed no voids between the enamel and the cured sealant.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 203-217 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The adsorption of fibrinogen from single solution and from mixed solution with albumin and γ-globulin has been followed at the air-buffer, isooctane-buffer, and methylene iodide-buffer interfaces by the pendant drop technique. Fibrinogen is shown to form substantial coherent films on isooctane and methylene iodide, suggesting considerable unfolding and lateral association. From this, a novel hypothesis has been proposed to account for the dominance of fibrinogen adsorption from mixed solutions on certain hydrophobic surfaces, in which the spreading pressure of rapidly unfolding fibrinogen molecules is sufficient to desorb other plasma proteins.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 233-240 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Five composite filling materials were finished using six finishing procedures currently in clinical use. The average roughness produced by each procedure was measured by means of a Surfanalyzer with four replications for each procedure on each of the five materials. Statistical analysis indicated that finishing with silicon carbide disks produced the smoothest surfaces. Acceptable surfaces were obtained with stones or with burs. Use of an alumina paste after a green stone-white Arkansas sequence did not produce a significant improvement.Two processes of filler particle abrasion were distinguished by means of electron microscopy: wear and shear. Fracture striations indicated particle shear.The roughest surfaces were produced by the use of a diamond instrument which is contraindicated. Acceptable finishing procedures for the composite materials tested include silicon carbide disks for accessible areas or 12 fluted finishing burs for more inaccessible areas.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 249-254 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The daily in vitro release of hydrocortisone from composite polymer capsules is reported here for over 120 days. Increase in vinyl acetate comonomer content of the ethylene-vinyl acetate copolymer matrix brought about an increase in the diffusion rate. Variation in the initial drug content of the capsules from 40 mg to 20 mg affects the daily drug release less significantly than the variation in copolymer ratio. The correlation between vinyl acetate comonomer content and the percent crystallinity of the copolymer matrix is suggested as one of the possible major factors in controlling diffusion rate from this drug-polymer system. The diffusion constant (D) calculated was 0.212 × 10-10 cm2/sec when the copolymer carrier has 30% vinyl acetate content and 0.430 × 10-11 cm2/sec when the copolymer carrier has 20% vinyl acetate content for capsules with 20 mg initial drug content, and 0.118 × 10-11 cm2/sec and 0.226 × 10-11 cm2/sec, respectively, for capsules with 40 mg initial drug content.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Four self-curing acrylic bone cements were surveyed by infrared, solubility, viscometry, quantitative metallography, microscopy, and physical testing techniques: CMW, Palacos R, Sulfix-6, and Surgical Simplex P. Results show that these bone cements were primarily composed of poly(methyl methacrylate) and that no cross-linking was evident. Solubility analysis confirmed this latter observation, as the bone cements dissolved completely except for a small insoluble fraction, which was identified as the radiopaque filler. For each bone cement, the viscosity-average molecular weights of both the powdered phase and the cured two-phase product remained unchanged, varying overall from 1 to 5 × 105. Using standard quantitative metallography, porosity ranged from 1 to 8% and the dispersed powder phase decreased 11-46%. Microscopy revealed the nature of the porosity, radiopaque fillers, the powder size and shape, and the fracture morphology. From tensile and fracture toughness tests, five physical properties were determined at ambient conditions and at 37°C after conditioning in distilled water at 37°C for 10 months: the modulus of elasticity, the ultimate tensile strength, the elongation at break, the fracture energy, and the mean inherent flaw size. At ambient conditions, the ultimate tensile strength decreased 33-55% when compared with commercial unmodified poly(methyl methacrylate), Plexiglas G. While the fracture energy remained rather invariant, the mean inherent flaw size increased fivefold over the commercial acrylic tested. This marked increase in the mean inherent flaw size could lower the fatigue resistance of a material, since more and/or larger fracture initiation sites are available. When tested at 37°C after protracted conditioning, the deleterious trends observed at ambient temperature continued. To some degree, porosity, particle-matrix interfaces, residual stresses, low molecular weight products, inorganic and/or other organic additions, and water contributed to the inherent flaw size at the expense of the working stress. Several modifications are suggested by which the importance of these factors might be minimized.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 347-359 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The evaluation of the efficiency of polymer additives with special emphasis on uv absorbers and antioxidants in polyurethane elastomers has been completed. Aliphatic polyurethanes were chosen for this study because their properties closely relate to the requirements of maxillofacial prosthesis. The polyurethane elastomers were either synthesized by ourselves or formulated according to the manufacturer's recommendation. Eleven different types of uv absorbers, coupled with one antioxidant, were incorporated into the polyurethane systems. The Atlas twin-lamp carbon arc Weatherometer was used as the source of uv. The samples were periodically withdrawn for examination of yellowing and tackiness. It was found that, although the incorporation of uv stabilizers enhanced the uv resistance of polyurethanes, the problem of tackiness resulting from uv aging was not solved satiafactorily. The phenomenon of yellowing, however, was significantly improved, mainly due to the aliphatic structure of polyurethanes. The most promising uv absorbers are Tinuvin 770 and the combination of Tinuvin 328, ZnO, and an antioxidant. Their effectiveness in other polyurethane systems is not known and further research is underway to explore this field. Hopefully, these findings will greatly assist the successful application of polyurethane elastomers in maxillofacial prosthesis.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 381-399 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Heparinized dog blood was exposed to shear and foreign surfaces in conicylindrical test cells. The cells were injection molded from polycarbonate and were filled using a technique that avoided contact of the blood with air. Particulate-matter formation was measured and was found to be dominated by the surface-to-blood-volume ratio and to be independent of shear rate. Hemolysis was also measured and was found to vary linearly with shear rate and to increase with increasing surface-to-blood volume ratio. Thus, at low shear rates and high specific surface conditions, the degree of hemolysis was found to be minimal while particulate-matter formation was high. The results suggest that the safety of extracorporeal perfusion procedures cannot be inferred from hemolysis measurements alone. In one series of tests, a gas-blood interface was generated at a rate equivalent to the rate of surface renewal in conventional disc oxygenators. The gas-blood interface failed to contribute significantly to the damage indices, which suggests that the apparent superiority of membrane oxygenators may be a result of factors other than the absence of a blood-gas interface.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 433-433 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 435-472 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A microporous filler giving greatly improved finishability, systemic nontoxic X-ray opacification, low thermal expansion (27.2 × 10-6/°C), and satisfactory translucencies has been developed for dental composite resin restorations. These fillers are prepared from frits obtained by the low-temperature calcination of gelled inorganic sols followed by a pulsed high-temperature treatment. Composites prepared from these fillers are within the range of commercial products with regard to strength and setting contraction.
    Additional Material: 17 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 491-503 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Reconstituted bovine collagen has been used extensively in our laboratory as a carrier for immobilized E. coli L-asparaginase. The activity and catalytic stability of these collagen-asparaginase membranes can be altered substantially by conditions used in membrane crosslinking with glutaraldehyde. As the concentration of glutaraldehyde used in tanning is increased, the initial specific activity of collagen-asparaginase membranes decreased asymptotically to a limiting value. Similar results occurred when membranes were subjected to increasing time periods of tanning at a constant glutaraldehyde concentration. These observations point to a time-concentration relationship for glutaraldehyde tanning and its effect on the specific activity of collagen-asparaginase membranes. Specific activities of membranes tanned at glutaraldehyde concentrations of 5% or higher appear to be very stable over long periods of alternate storage and assay. This result, however, is not observed with membranes tanned at glutaraldehyde concentrations lower than 5% for short periods of time (approximately 30 sec to 1 min). It is not clear whether the instability of membranes tanned at lower concentrations of glutaraldehyde or shorter intervals of tanning is due to enzyme elution from the membrane or denaturation of the bound enzyme.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 541-555 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The corrosion of carved, burnished, polished, and burnished-polished samples of a conventional spherical amalgam was studied by anodic polarization in Ringer's solution. The effect of the variation of the mercury content from 40 to 60 wt% on the corrosion of burnished or polished samples was also investigated. It was found that burnished and burnished-polished samples corrode the least and carved samples the most. The current-density peak associated with γ2 was of greater magnitude in polished specimens than in burnished specimens throughout the range of mercury concentrations investigated. It is hypothesized that lower porosity and more ready passivation of the surface due to a high amount of γ2 are the reasons that burnished samples corroded less than polished samples in this anodic polarization test.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 571-578 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A method is shown by which to identify wear particles of implanted plastic materials in tissue. A Mettler FP2 hot stage was used to determine the melting point of different elastomer particles in normal histological sections between the crossed nicols. By using a microcolorimeter Type MPE (Leitz, Wetzlar, Germany), additional information about the molecular degradation of wear particles was obtained.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 585-590 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We describe the preparation and some of the properties of heparin-bound α-chymotrypsin that were obtained via activation of heparin with water-soluble carbodiimide. Immobilized enzyme has unchanged kinetic characteristics toward low-molecular-weight and macromolecular substrates. The heparin-bound enzymes could have a wide range of medical applications.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 599-625 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Surface configurations are vessels fabricated from tubing and plate, films deposited on the surface of vessels, and beads confined in vessels. The average association constant between thrombin and sites on commercial poly(methyl methacrylate) surface (Lucite) is near 4 × 108 liters/mole at 22°C, pH 7.0, and ionic strength 0.15. Depending on Lucite composition, average adsorption U, in molecules/cm2 of apparent solution-surface interface, ranges from 0.7 to 8.8 × 1011. Analysis based on the assumptions that solution dimensions are preserved, adsorption is random, and surface rearrangement is negligible indicates a paucity of surface sites. Plasma albumin competes with thrombin for surface sites. Attempts to detect, by thrombin adsorption, the presence of free sites at 4.5 × 10-9 M albumin or the displacement of bound albumin indicate an albumin-site association contrast greater than 1.6 × 109. Cross-linked poly(methyl acrylate) bead surface has U less than 5 × 1010. In contrast to acrylic resins are silicone gum, polypropylene, and polyisobutylene, for which U ranges from 15 to 20 × 1011. Analysis as above indicates that sites are of frequent occurrence. Material composition suggests that thrombin can interact with nonpolar groups. Further characteristics of low-energy surfaces are that progressive surface denaturation is small and there is a large variance between nominally equivalent configurations.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A high-modulus polymer, polysulfone, was evaluated as a porous bone implant material. The bone ingrowth into canine cortical pellets of sintered polysulfone particles was assessed by microradiography and histology. The shear strength of the porous polysulfone-bone interface was determined by push-out and pull-out tests of cortical and trochanteric implants, respectively. Results indicated that the bone in-growth into porous polysulfone specimens proceeded in such a fashion as to mimic the normal repair at the site. Mechanical testing of cortical and cancellous implants revealed that the interfacial shear strength of the porous polysulfone-bone composite was similar to that achieved using porous metals.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 653-663 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A method is shown for deducing the surface area of a pendant drop from the same profile photograph as is normally used to determine interfacial tension. Manipulation of such drops by a micrometer syringe then enables the pendant drop to be used as a surface balance for studying adsorption from bulk solutions. Results are given for the compression of films from solutions of albumin, γ-globulin, fibrinogen, albumin-γ-globulin mixture and albumin-γ-globulin-fibrinogen mixture, and from serum, plasma, and blood at the isooctane-buffer interface. It is suggested that γ-globulin and fibrinogen films are unfolded at the interface but that albumin films are different in that they consist of an inner, unfolded layer and an outer, globular layer. A film from serum resembles that from γ-globulin alone, and not that from albumin-γ-globulin mixture, whereas a film from plasma resembles that of fibrinogen at low compression and that of albumin-γ-globulin-fibrinogen mixture at high compression. A film from blood is shown to resemble that from plasma.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 701-706 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The rates of adhesion of melanoma cells (carcinogenic) onto nonionic polymer surfaces were studied by using radioactively labeled cells and measuring the fraction of cells which adhered to the surface in a given time. Glow discharge (plasma) polymerization of 1,1,3,3-tetramethyldisiloxane and of nitrogen-acetylene-water (mole ratio 0.4:1.0:0.2) was used to modify the surface energy of the substrate. The cell adhesion rate was found to be given by Y = 1 - exp [-k0(γs - γ0)t], where Y is the fraction of cells adhered, - k0 is a characteristic rate constant, γs is the total surface energy of the substrate, γ0 is the threshold surface energy of cell adhesion, and t is time.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An ideal combination of mechanical and corrosion properties of long-term implants such as joint endoprostheses has yet to be found. Besides being resistant to pitting and crevice attack, which can lead to corrosion fatigue and stress corrosion cracking failures, the implant material must be highly resistant to wear and abrasion. Two cobalt-based alloys, wrought CoNiMoTi and air-cast CoCrMo, were subjected to a number of selected in vitro electrochemically and chemically accelerated corrosion tests in chloride-containing solutions with wrought AISI-316L used as a reference alloy. A limited number of immersion tests in FeCl3 and acidified FeCl3 solutions were also conducted. It is found that the mechanical properties of wrought CoNiCrMoTi alloy qualify it as a substitute for cast CoCrMo alloy and wrought AISI-316L in anchorage shaft production for all types of joint endoprostheses. Wrought CoNiCrMoTi has a higher resistance to fatigue cracking compared with cast CoCrMo and is as resistant to selective corrosion phenomena such as stress corrosion cracking.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 591-597 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Measurements of the permeability coefficients of various compounds up to a molecular weight of about 70,000 have shown clearly that membranes prepared from hydrolyzed polyacrylonitrile are about 10 times more permeable than those made of poly(2-hydroxyethyl) methacrylate. The higher permeability is probably due more to the higher water content (about 75%) than to the type of network. The high mechanical strength of the membranes and their good permeability to compounds possessing a comparatively high molecular weight seem to designate the material for some new applications in medicine.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 635-651 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A study has been made of the fractures and associated material from 34 prostheses broken in service. All the fractures appear to be of the fatigue type. Search by me-tallographic analysis for cracklike generating defects in material near the fracture reveals such conditions as abnormally coarse crystals, large nonmetallic inclusions, large inclusion population, undissolved master alloy particles, abnormal carbide segregation, interdendritic segregation, shrinkage, and gas porosity. Recommendations are made for the choice of metallic alloys for femoral stem application.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 679-700 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The effect of combining gentamicin and cephalothin with Surgical Simplex bone cement was tested in vitro. Experiments were designed to determine (1) quantitative elution rates and period of time the antibiotics were eluted and (2) effective bactericidal qualities. Both antibiotics were eluted from polymerized acrylic cement in large quantities within 24-48 hr after coming in contact with fluid and continued to be released in smaller amounts for 21 days to more than 175 days. This varied with the antibiotic, concentration of antibiotic in the cement, surface area of cement, and volume of elution fluid. Quantitative determinations of numbers of bacteria in broth cultures demonstrated that sufficient quantities of antibiotics were released to be bactericidal to microorganisms within 45 min to 20 hr. This was dependent on the type of antibiotic, type of bacteria, concentration of antibiotic in the cement, and time of contact.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. III 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 39-50 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We have studied the contact interaction of platelets with hydrogels. In the form of microspheres, 0.6-1.0 μ, poly (glycol methacrylate) (poly HEMA) and poly (methyl methacrylate) beads cause platelets to aggregate at concentrations of about 108 beads/ml. Polyacrylamide and (20/80) poly (acrylamide-HEMA) copolymer were ineffective in aggregating platelets. The admixture of 20% methacrylate to polyHEMA rendered the beads inactive. Blood plasma components other than fibrinogen were found essential to the interaction of the beads with platelets. Near-infrared spectra of the hydrogels polyacrylamide and polyHEMA showed the water hydrogen bonds to be the same for both and different from those in pure water. The monomer HEMA is an inhibitor of platelet aggregation and the release reaction at levels of 0.1%. It is concluded that the two hydrogels have different blood compatibilities, which depend more on the network structures than the water structures in the respective gels.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 69-84 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The Avcothane 51 elastomer, a member of a series of proprietary materials best characterized as polyurethane/poly(dialkylsiloxane) block copolymers, displays considerable hemocompatibility without any incorporated anticoagulants. In the form of intra-aortic balloons, the elastomer was implanted in several thousands of cardiac patients without intolerable hematologic effects. Hemocompatibility has been assumed to result from a predominantly dispersion-type surface force field whose intensity fluctuates within small domains, maintaining adsorbed blood proteins in an unstable state. The relative hemocompatibility of films, which were obtained from a prepolymer solution cast on substrates impenetrable to the solvent, is a function of the effective surface molecular structure. This can vary as a function of preparative conditions (temperature and rate of evaporation), and has been correlated with an anisotropic distribution of the silicone component in cured films. The concentration of this component in surface layers was quantified independently by IRATR spectroscopy and electronmicroprobe analysis, giving consistent results. An IRATR index, which is computed from the ratio of absorptivities measured at 13.00 and 12.62 μ and is inversely proportional to the relative silicone content of surface layers, was found to correlate with the apparent hemocompatibility determined by different in vitro methods. Optimized reproducible hemocompatibility is attained by strict process controls.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 157-164 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Examination of a great number of tissue samples taken from the newly formed capsules surrounding artificial joints reveals small particles of prosthetic material. Abraded from the joint by wear and tear, these particles of plastic, metal, and acrylic cement initiate a foreign-body reaction and result in the formation of granulation tissue, including macrophages and foreign-body giant cells. Typical features of tissue reactions exist for each of the materials from which prostheses are made. The consequent formation of scar tissue produces a thickening of the capsule, which, in turn, may cause a reduction in the mobility of the joint.In small amounts, the foreign-body particles are eliminated via the perivascular lymph spaces. Where this transport system is insufficient to handle the volume, however, the foreign-body response may extend to the whole environment surrounding the joint. In such cases, there may be loosening of the cemented prosthetic parts because of deterioration of contiguous bone anchors by the tissue membrane lining the bone cement.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 179-186 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An evaluation of a porous biodegradable ceramic, tricalcium phosphate, has been carried out. When implanted in cancellous bone, it is rapidly infiltrated with bone and slowly resorbed. When held rigidly against raw, bleeding, cortical bone, again rapid bone ingrowth occurs.The material does not give rise to any untoward tissue reaction, nor does it cause any systemic reaction. It can therefore be concluded that the material is safe for use in clinical practice, and can be used in specific instances either to replace or to supplement bone grafting.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 223-235 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The preparation and some properties of microspheres composed of oxidized polysaccharides and some vinyl polymers are described. The microspheres contain immobilized enzyme and can be slowly solubilized in water solutions, thereby releasing active a enzyme into the surrounding medium. The kinetic characteristics of the immobilized enzyme bound with a fragment of matrix after complete solubilization are unchanged, but the enzyme exhibits high thermostability. These preparations could have a wide range of medical applications, e.g., to form a drug “depot” directly in an affected organ.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 251-265 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A new antithrombogenic polymer was synthesized by photoinduced graft copolymerization of both a hydrophilic polymer and a cationic polymer to hydrophobic poly (vinyl chloride) copolymer, and by quarternizing and heparinizing the obtained graft copolymer.For polymers of various compositions obtained by the method described above, chemical composition, water absorption, membrane potential, and quantity of adsorbed heparin were determined and antithrombogenicity evaluated in vivo. Thus, it has been found that the polymer of excellent antithrombogenicity has a negative membrane potential, a moderate elution rate of heparin, adsorbs heparin in a quantity of approximately 15 wt-%, and has a degree of water adsorption of about 30 wt-%. Also, measurement of membrane potential was very useful for the estimation of the quantity of the adsorbed heparin and its change with time.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 339-346 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The influence of heat treatment of dental alloys at several temperatures on the phases present in the alloy and the creep of the resulting amalgam as well as the correlation between phase changes and the creep was investigated. A dependence of the creep on the temperature of the heat treatment of the alloy was established. Substantial phase changes were observed after the different heat treatments. No correlation was detected between the creep rate and the changes in phases present in the dental alloys. A thermodynamically oriented explanation of the relation between the creep of the amalgam and the state of (non-) equilibrium of the corresponding amalgam alloy was proposed and discussed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 347-364 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Techniques are described for fabrication of electrode arrays for stimulation and/or recording from a human cerebral cortex. These arrays may be neurosurgically inserted (with or without a Penrose drain) in the course of a conventional craniotomy or craniectomy, and are easily removed without reopening the ineision. Termination of the connecting wires in a special percutaneous pedestal has also permitted chronic implantation. The contacts and connecting wires are made of pure platinum embedded in a Teflon ribbon-cable matrix. The choice of materials combines biological acceptability, electrochemical stability, and integrity of the insulation, but imposes special fabrication procedures.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 405-422 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A series of copoly(α-amino acids) with varying percentages of hydrophilic (l-aspartic acid) and hydrophobic monomers (l-leucine, β-methyl-l-aspartate, and β-benzyl-l-aspartate) were implanted subcutaneously in rats and the macroscopic degradation behavior was studied. Three groups of materials (A, B, C) with different ranges of hydrophilicity were distinguished: A) hydrophobic materials showed no degradation after 12 weeks; B) more hydrophilic materials revealed a gradual reduction in size of the samples, but were still present after 12 weeks; and C) hydrophilic copolymers disappeared within 24 hr.The tissue reactions caused by the materials of group A resembled that of silicone rubber, whereas those of group B showed a more cellular reaction.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 435-445 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In vitro mechanical tests have been performed on a variety of LTI pyrolytic carbon blade-type dental implants, and the test results have been analyzed using an analytical model. Tensile stresses at fracture were calculated to be about 5 × 104 psi and 8 × 103 psi in the LTI carbon coating and the graphite substrate, respectively. These values are close to their respective fracture strengths. The fracture loads predicted by the model are in good agreement with data obtained from the mechanical tests and are higher than forces expected in mastication.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 471-481 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Spiral-coiled membrane lungs of 0.6 m2 surface area were fabricated from silicone rubber membranes coated with four types of commercially available pure-gum polysiloxane rubber: 1) polytrifluoropropylmethylvinylsiloxane, 2) polymethylphenylsioxane, 3) polymethylvinylsiloxane, and 4) polydimethylsiloxane.Membrane lungs were tested in an arteriovenous shunt without added heparin after bypass was begun. All groups except group 4 had major rise in resistance to blood flow or clotting in over 33% of the membrane lungs studied, after 6 hr of bypass. Membrane lungs with polydimethylsiloxane (group 4) had no rise in resistance to blood flow during 24 hr of bypass and had the least amount of changes in blood platelet count.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 525-535 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Formation of opaque deposits on the anterior (air) surface of hydrophilic soft contact lenses is a problem worthy of investigation by all concerned. These deposits have been analyzed for biomaterials by chemical, biochemical, electrophoretic, and immunological techniques. Qualitative and quantitative chemical colorimetric tests revealed the presence of variable amounts of protein (5-10 μg/lens), carbohydrate (1.0-1.2 μg/lens), and phospholipids (0.01-0.05 μmole/lens). Cholesterol and glucose were not present at detectable levels. Fluorescent antibody tests with appropriate controls gave positive tests for albumin, lysozyme, γ-G-globulin, and α1-lipoprotein in the deposits, all proteins presents in tear fluid. Deposits were most effectively removed from the lenses by the combination of heat, sodium dodecyl sulfate (SDS) detergent, and the thiol reagent dithiothreitol (DTT). SDS-denatured protein migrated on polyacrylamide gels with electrophoretic patterns corresponding to molecular weights for those proteins detected by the above antibody tests. The nature of the bonding interactions of biomaterials to the lenses was probed by chemical reagents used to remove them, employed singly and in all possible combinations. Urea, guanidine hydrochloride, potassium thiocyanate, potassium perchlorate, hydroxylamine, and EDTA were much less effective than SDS and DTT. These data suggest that apolar interactions plus disulfide bonds may be important in stabilizing the deposit structure, and point to improved cleaning procedures.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 577-607 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Rapid and reliable methods for the characterization and quantitative determination of ingredients usually present in self-curing methacrylate bone cements were developed using spectrophotometric, gas chromatographic (GC), and conventional gravimetric procedures. These procedures are applicable to non-crosslinked methacrylate resins. In the presence of some copolymers, polymer blends or crosslinking agents, or other ingredients which will result in the formation of insoluble methacrylate resins, some modification of the identification procedures and quantitative estimation of the resin components will be required. Molecular weight and molecular weight distribution of the powder and cured cement were obtained from viscosity and gel-permeation measurements. Residual low molecular weight materials in the cured cement were determined for various storage times. Residual and water-leachable monomer and residual dimethyl-p-toluidine (DMPT) were measured by GC. In air, the monomer content of the cured resin decreased from 3.3% after 1 hr to 2.4% after 215 days. When stored in water at 37°C, over 65% of the extractable monomer is leached out within 10 min. After 6 hr, the rate of diffusion of monomer into the aqueous phase is low. The cured cement contains as much as 0.6% DMPT, which does not leach out. Residual peroxide, estimated spectrophotometrically, amounts to 0.8%, but decreases to 0.14% after 15 months in water at 37°C. A semiquantitative colorimetric test indicated that the hydroquinone content of specimens analyzed within 24 hr after curing amounted to 9 ppm.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 629-632 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 677-700 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The effect of collagen modification on the magnitude of stress-generated potentials has been studied. A whole bone model has been developed for determining the effects of collagen crosslinking on the electrical signals. Increased crosslinking results in larger electrical signals, and such increases result whether in vivo or in vitro changes in the collagen are made.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 671-676 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The peak temperature reached during the polymerization of a bone cement was reduced by addition of solid N-vinylcarbazole to the powder component. It was also necessary to saturate the liquid component with N-vinylcarbazole to prevent dissolution from the modified powder component on mixing. It is believed that this technique is generally applicable and opens up the possibility of achieving temperature control of bone cements with choice from a range of crystalline monomers.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 711-719 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study determined the difference in rate of degradation between pure polymers of lactic acid (PLA), glycolic acid (PGA), and various ratios of copolymers of these two substances. Fast-cured and slow-cured polyglycolide was compared with copolymers of glycolide/lactide intermixed in ratios of 75:25, 50:50, and 25:75, as well as pure polylactide. A total of 420 rats were implanted with carbon-14 and tritium-labeled polymers in bone and soft tissue. At intervals of 1, 2, 3, 5, 7, 9, and 11 months, groups of five animals with the implants in bone and five with the implants in the abdominal wall were sacrificed. The implant area as well as tissue from the liver, spleen, kidney, lung and some muscle tissue was analyzed for radioactivity along with the urine and feces collected throughout the experiment. Half-lives of the different polymers and copolymers were calculated from the radioactivity present in the implant area for each time interval. Half-life of the polymers and copolymers decreased from 5 months for 100% PGA to 1 week with 50:50 PGA:PLA copolymer and rapidly increased to 6.1 months for 100% PLA. Fast-cured PGA had a half-life in tissue of 0.85 months. No difference in rate of degradation was seen in soft tissue or bone. No significant radioactivity was detected in urine, feces, or tissue samples. From this study, it is concluded that control of degradation rate of the implant could best be attained by varying the composition of PLA and PGA between 75% and 100% PLA along with a corresponding 25% to 0% PGA. This would provide a half-life range of the implant of from 2 weeks to 6 months.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 767-786 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The feasibility of preventing platelet adhesion to porous foreign surfaces in contact with blood by passing (perfusing) a physiologic fluid through the pores into the blood was tested. Porous-walled tubes of Teflon (Gore-tex) and aluminosilicate ceramic were perfused with lactated Ringer's solution at rates between 3.13 and 0.3 cc/min per cm2 of perfused surface and exposed to heparinized and unheparinized flowing human whole blood for periods of 3-6 min. Under these conditions, with 0.159 cm I.D. tubes and a mean blood flow rate of 8.3 cm/sec, the adhesion of all blood cells was prevented, compared with the adhesion of 1 to 8 × 106 platelets/cm2 on the nonperfused controls. The adhesion of plasma proteins was also markedly reduced as determined by bromophenol blue staining.The critical perfusion rate to prevent platelet adhesion to Gore-tex (0.5 μ pore size, 60% pore volume) was found to be between 0.04 and 0.3 cc/ (min · cm2). The boundary layer produced by a perfused segment of porous tubing prevented platelet adhesion for several centimeters downstream from the perfusing segment under experimental conditions used.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 811-838 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The present status of skeletal fixation of permanent orthopedic implants by poly(methyl methacrylate) (PMMA) is discussed. It is proposed that alternatives to the acrylic cement can improve the skeletal fixation. The present paper is concerned with the fixation method by bone ingrowth into pores of the implant surface.Two different implantation models have been designed to investigate the influence of load bearing upon ingrowth in surface pores of the implant: intramedullary nails as a means of fixation of a femoral pseudarthrosis and hinged knee prostheses. In each animal, implants with identical material characteristics (pore size, density, and thickness of the porous layer) but different loading conditions were used: one implant was “statically” loaded, the other “dynamically.” This procedure allows the evaluation of ingrowth with regard to load bearing only.Two different mean pore sizes, viz., 87 and 110 μm, have been used with the two models. After an 8 week implantation period, bone ingrowth was evident for the statically loaded implants. Calcified tissue ingrowth was, however, not observed in the dynamically loaded implants. The discrepancy in bone ingrowth behavior between the statically and the dynamically loaded implants has been attributed to 1) the gross movement or the micromovement existing at the bone prosthesis interface and 2) the fact that the critical mean pore size for ingrowth with static loading is smaller than the one with dynamic loading.The experimental implantations allow still another conclusion: the results suggest that designs of present clinical prostheses fixed by bone cement cannot be used with the alternative fixation by bone ingrowth unless the deisgn has been changed in a fundamental way. Mechanical factors as well as the phenomenology of bone ingrowth fixation account for this conclusion.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 893-901 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A study has been carried out on the structure and surface texture of a new dental implant material composed of silica microspheres (3 or 5 wt %) and poly(methyl methacrylate). A recently developed composite material composed of vitreous carbon microballoons and poly(methyl methacrylate) has proven highly successful in clinical use, but the black color presents aesthetic problems at the gingival margin. The new material was developed in order to reproduce the many desirable qualities of the vitreous carbon-polymethacrylate composite, while omitting the black color. Square wafers (10 mm × 10 mm × 1 mm) were studied, with the surface sandblasted in half of the specimens. Light microscopy revealed an even spacing of spherical configurations throughout the material. Scanning electron microscope studies revealed a finely porous surface with many large craters in the sandblasted specimens.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 43-54 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An in vitro method has been developed for screening of candidate biomaterials in an early phase of their development. The test is based on L-929 mouse fibroblast cultures and their response to powdered polymer samples. It applies microscopic observation for the detection of morphological changes, uses dye exclusion testing for cell viability determination, and utilizes estimation of population doublings as an end point. The test is shown to be reliable and reproducible and is compared to in vivo implantation studies in rats, previously reported.
    Additional Material: 6 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Surgically produced fractures of rabbit tibiae were internally stabilized with in tramedullary rods of stainless steel (316LVM), titanium (6A1,4V), polyacetal (Delrin), and polyamide (Nylon 101). Periodic radiographs were taken until sacrifice at 16 weeks after fracture. Structural properties of the tibiae were determined in torsion with the rods in situ, and then the tissue was prepared for histology or microradiography.The results demonstrated that fracture remodeling was adversely affected by the metal rods. New bone was seen to have formed over the ends of the metal rods, and cortical bone resorption was observed in the fracture region, suggestive of transfer of mechanical stress to the rods, resulting in stress shielding of the diaphysis. Negligible osseous response to the polymeric rods was observed; fracture callus remodeling was extensive. The torsional test results demonstrated that fractures with polymeric rods were significantly stronger and tougher than those with metallic rods. With the exception of titanium, the strength of healed fractures was inversely related to the elastic moduli of the implant materials.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 37-43 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The degree of microleakage between a restoration and the cavity wall is difficult to quantify objectively. A silver-staining method is used and compared to the radioisotope method with results that indicate a superior definition and more accurate evaluation of microleakage. In addition to the accuracy, two advantages are presented: (1) scoring of the leakage can be refined and divided into more precise numbers, and (2) teeth can be observed directly in a microscope without resorting to the indirect interpretation of film or photograph.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 59-70 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Porous high-density polyethylene specimens were implanted in the femurs of mongrel canines. At the end of the residency period (3 or 6 months), the animals were sacrificed and the implants were retrieved. The work-of-fracture of the implant specimens was then determined using the technique of Tattersall and Tappin. The work required to fracture a specimen in three-point bending by controlled crack propagation through a triangular cross section was obtained directly from the load-deflection curve. The area of the resulting fracture surface was measured by macro-photographic techniques, and the work-of-fracture was calculated as work per unit area. The implants were subsequently sectioned and examined microradiographically to determine the extent of bone ingrowth. Bone specimens adjacent to the implants and porous high-density polyethylene controls (no ingrowth) were also tested to determine their work-of-fracture. The results showed that bone adjacent to the implant specimens had a higher work-of-fracture than normal medial, canine femoral bone and was not appreciably different from the composite. The work-of-fracture of porous high-density polyethylene was not significantly increased by an increase in bone infiltration, and this anomalous behavior was attributed to a degradation of the polyethylene during implant residence. Control studies supported this hypothesis.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Removal of bilirubin by hemoperfusion with ion exchange resin particles is suggested to replace exchange transfusion of blood of jaundiced infants in some cases of unconjugated hyperbilirubinemia. The hemoperfusion system developed here consists of a packed bed of a macroreticular resin which is made biocompatible by a coating of a monomolecular layer of albumin. The choice of the appropriate ionic form of the resin and the proper albumin coating and crosslinking procedure assures a high bilirubin adsorption capacity and excellent blood compatibility of the resin. The albumin coated resin removes in vitro 80-90% of the bilirubin initially present in the plasma. The results encourage in vivo clinical studies.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Double catheter systems consisting of a stiff outer catheter and a flexible, buoyant, flow-directed, inner catheter which is often balloon-tipped have been employed with increasing frequency recently in both therapeutic and diagnostic procedures. Their use, however, has been restricted because of the excessive friction generated between the two catheters. In an attempt to decrease friction between polymers commonly used as catheter materials, oxidation of polyethylene, fluorinated ethylene-propylene copolymer, poly(vinyl chloride), silicone rubber, and polystyrene surfaces was induced by exposing the polymers to radio frequency glow discharge (RFGD) in a helium environment. All polymers were surface characterized utilizing x-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and contact angle measurements before and after oxidation. This article describes the materials and methods used to fabricate and characterize the polymer surfaces and the results of the characterization. The results indicate that increases in oxygen concentration at the surface of the polymers and decreases in air-water contact angles occur with increased RFGD exposure time. Plateau values were usually obtained after 5-30 s exposure time, yet no apparent changes in surface topography were noted by scanning electron microscopy. The hydrophilic surfaces produced were stable for up to three months storage time in air.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 249-260 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The new composite concept of microfilled composites has certain advantages, such as polishability, permanent smoothness, and high abrasion resistance. In the mouth, however, these new materials are not perfect and they often fail in stress-bearing restorations. In the present study, the weak links and imperfections of these materials are determined by means of direct and indirect SEM techniques. The chemical adhesion between polymer blocks and polymer matrix is questionable; fractures occur most often at the filler-matrix interface. In vivo, there is still a certain preferential wear of the resin matrix. In Estic Microfill, rear weak zones with starlike condensations are observed, which could be related to a certain incompatibility of its composing resins and/or to incomplete and inhomogeneous polymerization. In a fractured Isopast restoration, the polymer blocks are clearly revealed, scattered in a three-dimensional polymerized matrix network.
    Additional Material: 18 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 205-227 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Ion beam etching has provided a system which can produce a controllable surface morphology in the micron range without altering surface chemistry or surface energy. PTFE (polytetrafluoroethylene) develops a surface texture having conical projections with average dimensions: height = 12 μm, base width = 4 μm, tip radius = 0.1 μm. Smooth and textured PTFE disks (1 cm diam. × 250 μm thick) were implanted subcutaneously into the dorsum of Sprague-Dawley rats for time periods of 1 and 3 days and 1,2,3,4, and 8 weeks. Smooth control samples consisted of untreated surfaces and surfaces that were exposed to an ion beam environment producing a smooth surface. All smooth surfaces behaved identically by both histochemical and histological methods. Consequently, the ion beam environment had no effect on the soft tissue response. Textured surfaces, however, demonstrated increased cell adhesion and increased succinic dehydrogenase and acid phosphatase staining in the interfacial cells. Interfacial cells consisted of foreign body giant cells and macrophages. These macrophages possessed increases in the cytoplasmic-to-nuclear ratio, number and interdigitation of filopodia, and vacuolization as demonstrated by TEM. The textured surfaces also influence the kinetics of fibrous capsule formation. At 8 weeks, capsules associated with textured interfaces were reduced in thickness by 30% when compared to smooth surfaces. The results of this investigation demonstrate that the surface texture of an implant is a critical variable in determining the soft tissue response to a material.
    Additional Material: 20 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 359-373 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Some physical, chemical, and biological characteristics of a heparin-PVA hydrogel potentially useful as a thromboresistant coating for the preparation of small-diameter vascular prostheses and blood-sampling catheters have been determined. The molecular weight between crosslinks in the acetal crosslinked gel was approximately 8000, permitting proteins the size of albumin to enter the interior of the gel. The release rate of heparin from a gel containing 7 mg/g gel was 10-2 μg/g min which was significantly lower than the reported minimum required for thromboresistance of ionically heparinized materials. Nevertheless, in vitro biological activity was observed in both thrombin time and plasma recalcification time assays, which could not be attributed to the release of heparin into the incubated plasma. Correlation of final heparin contents with the amount of terminal amino acid residues in three samples of heparin suggests that the heparin is bound to the PVA in the gel through the amino acid terminus; this provides a plausible explanation for the retention of biological activity by the immobilized heparin.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 389-391 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 395-410 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The flexural strength, microstructure and relative Ca and Si concentration at the surface of two commercial orthopedic aluminas were studied before and after aging up to 52 weeks in simulated body fluids or in subcutaneous implantation in rodents. There was no significant reduction in flexural strength after aging, but there was evidence of Ca and Si dissolution from the external grain boundary surfaces, particularly for specimens aged in demineralized water. No change occurred in the Ca and Si concentrations within the specimen's bulk during either in vivo or in vitro aging.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 669-678 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Biochemical features of pseudomembrane formed at the bone-cement interface of 13 failed total hip replacements were studied and histological examination of the pseudomembrane was conducted. The results of biochemical analyses revealed on average hydroxyproline, 86 μg/mg; water content, 57%; hexosamine, 12 μg/mg; glucosamine/galactosamine, 1.4%; and calcium, 2.1%. Approximately 78% of collagen was extracted with pepsin, whereas only 8 and 0.3% collagen were extracted with acetic acid and neutral salt, respectively. On further differential salting out of the extracted collagen, about 77% was type I collagen, 19% type III, and 2.6% type V. Unlike pseudoarthrosis of fracture, no type II collagen was identified. Overall biochemical features in the light of the histological appearance suggested that pseudomembrane resembles granulation tissue. Bone healing mechanisms at the bone-cement interface appear to differ from that of fracture healing.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 691-713 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Dental porcelain frits have been prepared by the gel route, a procedure involving solubilization of alkalies, boron, rare earth, and other compounds in an alumina-silica sol. Using this procedure, porcelain frits suitable for metal-ceramic application have been prepared that fire to maturity at temperatures lower than current commercial porcelains. Solubilities, translucencies, thermal expansion coefficients, dilatometric softening temperatures, and flexure strengths are within the ranges of current commercial porcelains. The high degree of dispersion of pigments and phosphors made possible by gel route technology and the technology's ability to disperse crystalline phases to strengthen porcelain offers many processing advantages. Gel route technology also offers a great degree of freedom in modifying porcelain properties.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Cell spreading and cell division rates of a transformed line of mouse lung fibroblasts were studied on various polymer surfaces in the presence of serum proteins. The bare polymer surfaces, as well as the protein-coated surfaces, were characterized by their polar (γsp) and dispersion (γsd) surface free energies. Cell spreading appeared to be dependent on the polar surface free energy. Cell spreading is low when the γsp of the bare surface is lower than 5 erg cm-2; marked spreading occurs when γsp is higher than 15 erg cm-2. A similar relationship was found between cell spreading and polarity of the protein-coated surfaces, although less pronounced than for the bare surfaces. Cell spreading appeared independent of the dispersion surface free energy. Cell division rate was the same on all surfaces tested.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 819-828 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Strain measurement within the cement surrounding stemmed total hip femoral components was accomplished using PMMA encapsulated and embedded strain gauges. Cement strain measurement associated with a well-bonded stem-cement interface and an unbonded stem-cement interface (i.e., loose prosthesis) was performed. The presence of a stem-cement bond was found to reduce proximal cement strain magnitudes while having little effect on distal cement strain magnitudes. The assurance of a stem-cement bond on only the proximal third of the interface was found to have an effect similar to that of a complete stem-cement bond. The results of this experimental investigation confirm the theoretical prediction that the stem-cement bond is important in maintaining the integrity of the cement mantle surrounding a stemmed femoral component.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 855-864 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We report development of special macroporous semipermeable membranes and diffusion chambers made of polymerized 2-hydroxyethyl methacrylate (pHEMA), synthesized specifically to enclose living insulin-producing pancreatic islet cells for the treatment of diabetes. This material was selected to minimize the fibrotic encapsulation which has limited hybrid artificial pancreas efforts with other membranes, including Millipore and Nuclepore filters. The pore density and pore size distribution were dependent on the ratio of water to HEMA monomer and also on the crosslinker (EGDMA) concentration. A macroporous membrane resulted only when the ratio of water/HEMA monomer was greater than 50%. 125I-insulin permeability was studied in vitro. A technique is also described to fuse the membranes to form diffusion chambers used for implantation into diabetic rats.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 899-899 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 903-903 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A single particle and four blended Cu-rich amalgam systems were immersed in 37 °C solutions for 1-20 months in order to determine the characterization and sequence of corrosion product formation. X-ray diffraction and SEM/EDS were used to characterize the products. The same sequence of formation occurred in all systems in Ringer's and 0.1% Ringer's solutions. The times at which each product formed varied with the brand of the amalgam and the concentration of the solution. The initial products were ZnSn(OH)6 in Zn-containing systems and SnO2 in most other systems. Cu2O formed next, followed by CuCl2·3Cu(OH)2. Immersion in 1% Na2S yielded only HgS on all brands. A combination of 1% Na2S and Ringer's solution yielded CaSn(OH)6 after 2 months and Cu2O at later periods. Artificial saliva resulted in a retardation of corrosion product formation and only limited amounts of a Sn-rich product could be found after 20 months. Interactions of the various components appear to alter the nature and rate of corrosion product formation on these systems and additional systematic investigations are necessary to understand the influence of these interactions on corrosion.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 945-957 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Quantitative hemolysis assays of acrylate and methacrylate esters provided estimates of the intrinsic hemolytic activity (Hi the slope of the concentration-response curve) and the concentrations effecting 5% (H5) and 50% (H50) hemolysis. The dependence of hemolytic activity and LD50 (mice) on physical properties (lipophilicity, molar refraction, and molecular volume) of the esters was determined by multiple regression analysis. The observed correlations were: Hi, R2 = 0.94; H5, R2 = 0.95; H50, R2 = 0.94; and LD50, R2 (all compounds) = 0.80, R2 (all compounds less the methyl esters) = 0.94. The difference of the methyl esters was associated with the smaller steric volume of the methyl ester substituent and the presence (methacrylates) or absence (acrylates) of the branched methyl group. Associative steric contributions of the branched methyl group and the ester substituents were probably responsible for greater variability in the methyacrylate series. The results were consistent with the conclusion that the mechanism of the action of the esters is membrane mediated and relatively nonspecific and that in vivo biotransformation was not a significant factor. Also, long-term toxic liability of the esters may be more closely related to intrinsic toxicity than acute toxicity.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 993-1002 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A series of porous polymeric sorbents and activated carbon were used to remove di-isopropyl methylphosphonate (DIMP) from human plasma and normal saline. The sorptive capacities of the commercially available sorbents Amberlite XAD-4, XAD-2, XN1010, and XE348, and Calgon 400 were determined. Butyl- and palmityl-grafted XAD-4 were prepared with graft efficiencies of 32 and 6%, respectively, and tested for sorptive capacities. DIMP removal efficiencies were compared to dialysis with a 1.8 m2 Cordis-Dow hollow fiber artificial kidney (HFAK). Butyl-grafted XAD-4 and active carbon outperformed the other sorbents in removing DIMP from both saline and plasma. An order of magnitude reduction in removal ability was noted for all the adsorbents when the mobile media was plasma. Pronounced plasma precipitation was elicited by activated carbon, an effect not observed with any of the polymeric resins tested. The removal efficiencies on a 18.0 g basis of XAD-4, butyl-grafted XAD-4, and active carbon were comparable to that of the HFAK used in this study. These sorbents, however, possess a macroscopic surface area of approximately 0.1 m2, an order of magnitude lower than that of the HFAK. This reduction in contact area is believed to reduce substantially the possibility of undesirable molecular and cellular effects.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Normal and carbon-fiber-reinforced (1 wt. %) bone cement samples were tested in compression at various strain rates. Both the compressive strength and proportional limit increased in general with increasing strain rate. Similar strain-rate sensitivity was also shown by the carbon-fiber-reinforced bone cement. The mechanical properties, namely the modulus of elasticity, the proportional limit, and the compressive strength of the carbon-fiber-reinforced bone cement showed highly significant positive correlations with the strain rate.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 1079-1087 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. v 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 413-425 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A complete study of the static and dynamic strength of complete maxillary dentures was undertaken. First, the denture base material was investigated in its various forms from the point of view of tension, creep, relaxation, fatigue, and the effect of a corrosive environment. Complete dentures were tested under static compression, and the distribution of stresses along the midline of the upper dentures was determined by means of strain rosettes and by reciprocating compression, the determination of their fatigue strength. The results were found to conform with experience as far as lifetime of complete dentures is concerned.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 435-462 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Many authors have examined the mechanical properties of bone cement and the various factors that affect its mechanical behavior. This article presents a comprehensive survey on the reported mechanical properties of bone cement. Variables that influence the mechanical properties, such as handling characteristics, strain rate, loading modes, additives, porosity, blood inclusion, in vivo environment, temperature, etc. have also been reviewed. The importance of specifying these variables in reporting test results on the mechanical properties of bone cement is pointed out. Previous attempts to improve the mechanical properties of bone cement are also summarized. Future research areas important for fully characterizing the physical properties of PMMA are also suggested.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 137-146 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Randomly cross-linked copolymers of 2-hydroxyethyl-methacrylate (HEMA) and methyl-methacrylate (MMA) have been prepared and studied in the dry and swollen state. Tensile and indentation tests indicate that by changing the composition of copolymers, it is possible to obtain materials with a wide range of mechanical properties and corresponding glass transition temperatures. Water diffusion coefficients in sorption and desorption experiments have been calculated and compared.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Although dogs have been used widely to study the healing of large caliber synthetic grafts, hypercoagulability probably makes the dog a poor model for studies of small caliber vascular prostheses. The baboon's coagulation system is similar to man's, but large caliber baboon grafts were reported to endothelialize rapidly. In this study the healing pattern of 4mm internal diameter Dacron carotid interpositon grafts in baboons was determined using specimens harvested at time points between 2 weeks and 18 months post-implantation and examined with light and scanning electron microscopy. The luminal surface of baboon grafts in the acute healing phase (〈1 month) was comparable to that reported in the literature for dogs. Baboon grafts did not completely endothelialize until 10-12 weeks post-implantation. For work with small caliber vascular protheses, the dog appears to have no advantage over the baboon as an animal model on the basis of graft healing.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 395-401 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The macrophage plays a pivotal role in both wound healing and cellular response to implants, including percutaneous devices. Within twenty-four hours macrophages were found in close contact with the implant surface. Eventually fibroplasts and connective tissue proliferate, and finally the implant will be encapsulated. The presence of macrophages is essential for the activation of collagen synthesis by fibroplasts. Implant shape and surface can profoundly affect macrophage behavior. At rough implant surfaces macrophages with giant cells are present for many months with the possibility of chronic granulomatous reactions. Superior tissue compatibility should be associated with smooth, well contoured implants with no acute angles.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 427-434 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A Ni-45 wt % Ti (Ni-50 at % Ti) alloy was cast into molds of magnesia and silica investments by use of a dental argon-arc pressure casting machine with a copper crucible. The castings exhibited shape memory properties. The shape recovery process was sharper in the specimens cast in magnesia investment molds than in those cast in silica (phosphate-bonded) investment molds. The latter casting had a hard region of the periphery, suggesting that shape recovery process may be affected by reaction of molten metal with silica. Furthermore, the alloy possessed the adequate mechanical properties for consideration as crown-and-bridge prostheses.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The release of corrosion products by implants has become a matter of concern. Using a microsphere model, the release of chromium, cobalt, and nickel, secondary to implantation of various surface area exposures of F-75, a cast cobalt-chromium alloy, was studied over a 30 day period in the rat. Dose related elevations were observed in the serum concentration of chromium and cobalt but not of nickel, with the maxima being achieved at 3 days after metal implantation followed by declines in concentration. The chromium elevation, approximately twelvefold for a surface area to body weight (SA/BW) ratio of 300 x is similar to that previously reported in patients receiving total hip replacement arthoplasties. However, the cobalt elevation, twentyfold for a SA/BW ratio of 300 x, has not been previously observed. These serum concentration changes are as yet unexplained, but are probably not due to fibrous capsule maturation or alloy repassivation.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 547-559 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An in situ immunoradiometric assay was devised to quantitate human fibrinogen deposited on hemodialysis membrane, Cuprophane, from in vitro exposure to fibrinogen solution and from ex vivo extracorporally clinical use. The method requires a monospecific 125I-labeled antifibrinogen-IgG purified by DEAE chromatography and immunoadsorption. The labeled antifibrinogen IgG was shown to react specifically with fibrinogen adsorbed and immobilized (by glutaraldehyde) on Cuprophane. Other plasma proteins such as human albumin, IgG, or α-thrombin, adsorbed singly or coadsorbed with fibrinogen on the surface did not seem to affect the fibrinogen-antifibrinogen reaction. The presence of blood cells such as platelets and granulocytes with fibrinogen on Cuprophane reduced only slightly the uptake of 125I-antifibrinogen-IgG. The examination of fibrinogen-fibrin deposition on clinically used Cuprophane by this technique and by autoradiography of the same material following 125I-antifibrinogen-IgG conjugation indicated that the deposition of fibrinogen was heavy and heterogeneous. We concluded that this in situ method may be useful to monitor fibrinogen-fibrin deposition and adsorption of other plasma proteins that occur under in vitro, ex vivo, and in vivo conditions.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 601-607 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study was undertaken to examine the effectiveness of a commercially available n-butyl-2-cyanoacrylate (Histoacryl blueTri-Hawk International, 1570 Barré, Montréal, H4L 4M6 Quebec.) as a local treatment for cutaneous ulcers. Two ulcers, approximately 0.5 cm2 each, were made on the backs of 30 hamsters. The right side was covered with a thin film of tissue adhesive, while the left side was left untreated as a control. Animals were sacrificed at various times post-operatively, the tissue excised, processed, and examined with the light microscope. Results showed that cyanoacrylate decreased the inflammatory exudate early in the experiment, and epithelial migration occurred slightly earlier in experimental tissue. Scab formation was absent in experimental sites until the layer of adhesive was lost. After 2 days, healing was comparable in both experimental and control, and the sites were indistinguishable histologically at day 5.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 895-909 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An alternative to the usual technique of preclotting porous textile vascular prostheses prior to surgical implantation is to render them impermeable to blood by impregnation with a cross-linked albumin filler matrix. This material subsequently becomes the foundation for cellular development. The compatibility of such impregnated fabrics with newly formed endothelial cells has been evaluated by an in vitro organotypic culture method. This technique enables the characterization and numeration of cells that develop on blood contact surfaces and enables determination of their rate of development. Woven, knitted, and velour fabrics were evaluated folllowing coating with albumin and either storage in Tyrode solution or 40% ethanol or desiccation by critical point drying. Preclotted cardiovascular repair fabrics prepared according to conventional surgical protocol served as controls. The identification of the newly formed cells was confirmed histologically. The most extensive and rapid cellular development was observed on the woven fabric and is believed may have resulted from the smoother surface topography of this substrate. Good cellular development was noted particularly on fabrics which had been stored in Tyrode solution. Ethanol had a deleterious effect on the apparent compatibility.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 695-705 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Human prothrombin in Tyrode's solution, in mock plasma (albumin, fibrinogen, and IgG mixture), and in citrated plasma adsorbs to Cuprophane, polyvinylchloride, and polyacrylonitrile surfaces. The adsorption of prothrombin is maximal in Tyrode's solution and minimal in plasma. The surface concentrations of prothrombin are highest on polyacrylonitrile, second on polyvinylchloride, and lowest on Cuprophane at all prothrombin concentrations tested in the bulk solution. Qualitative tests show that prothrombin adsorbed to polyvinylchloride can be activated by Taipan snake venom to generate thrombin that clots fibrinogen. However, more quantitative tests indicate that only part of the adsorbed prothrombin on all three materials can be activated to form thrombin exhibiting amidolytic activity. The partial reactivity of adsorbed prothrombin is further confirmed by release of 125I-peptide from surface bound 125I-prothrombin after treatment with Australian Taipan snake venom. Prothrombin bound to Cuprophane seems to promote granulocyte adhesion, but has no effect on platelet adhesion.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 727-736 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Bovine pericardial tissue and tissue-derived bioprosthesis fixed in glutaraldehyde and stored in either glutaraldehyde or formaldehyde can induce cytotoxic reactions even after prolonged washing due to the slow leaching of the chemicals used for crosslinking and sterilizing. Sequential rinsing for up to 60 min was still not sufficient to eliminate cytotoxic effects. On the other hand, satisfactory results were obtained when cardiac valves made from glutaraldehyde fixed pericardium were stored in a solution containing 0.02% of propyl-hydroxy-benzoate and 0.18% methyl-hydroxy-benzoate. The valves stored in this solution and rinsed three times for 1 min in normal saline showed few signs of residual cytotoxicity. Rinsing in a solution containing glycine was partially effective in neutralizing the cytotoxic effect, and this or similar approaches offer good possibilities. The use of Chang cells grown in culture provides an excellent quantitative assay for the assessment of residual cytotoxicity and for evaluating the host response to different methods of fixation, storage, and rinsing of tissue derived bioprosthesis.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 771-779 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Few in vitro systems for testing dental restorative materials have taken into account the protection afforded by the residual dentine in vivo. In turn opinions differ as to whether an increase in residual dentine thickness increases this protection. In this study an increase in the depth of dentine powder beneath zinc oxide eugenol (ZOE) reduced its toxicity, while this was not the case with the glass ionomer cement. Compaction of the powder had no effect, suggesting that protection was due to binding of the toxicant to the dentine rather than it acting as a physical barrier. Protein was shown to be very important in moderating the cytotoxicity of ZOE. These results suggest that in vivo the irritancy of some materials may be related to the depth of residual dentine but not others. The effect of exposure period and volume of these materials on their cytotoxicity was also investigated. Increasing the volume of ZOE while retaining the same surface area increased the toxicity of ZOE, while with the glass ionomer it had no effect.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 881-894 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The macromolecular properties of 17 virgin commercial arterial prostheses and a series of explanted prostheses, both manufactured from poly(ethylene terephthalate) (PET) yarns, have been studied by gel permeation chromatography (GPC) and by differential scanning calorimetry (DSC). Only small differences were found between the average molecular weights and the degree of crystallinity of the unused reference grafts. A broadening of the DSC curves was observed for the prostheses containing texturized yarns compared with those made solely from flat, untexturized yarns. This broadening may be due to greater heterogeneity of the crystal sizes caused by the texturizing process and to the use of two or more different yarns with dissimilar thermal histories in the same prosthesis. Average molecular weights of the explant series were significantly lower than those of the corresponding reference grafts but almost time independent. The polydispersity index and the degree of crystallinity of the explants remained constant as a function of time. These results are discussed in regard to others available in the literature.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A cage implant system was utilized to quantitatively and qualitatively characterize in vivo leukocyte interactions with cast Biomer. Scanning electron microscopy (SEM) in conjunction with cytochemical staining procedures were used to investigate the cellular events at the leukocyte/Biomer interface as well as in the inflammatory exudate over a 21-day implantation period. SEM was used to characterize leukocyte morphology on the Biomer surface and the cytochemical stains were used to differentially count leukocytes and to demonstrate intracellular alkaline and acid phosphatase activity. The results showed that the population density of leukocytes on the Biomer surface diminished with implantation time. The population density of multinucleated foreign body giant cells remained constant with time, while the numbers of nuclei per giant cell increased. The differential analysis revealed that macrophages preferentially adhered to the Biomer surface compared to other leukocytes in the exudate. The phagocytic capability of all adherent leukocytes, including giant cells, decreased with time and this corresponded to changes in leukocyte morphology observed with SEM.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 1017-1030 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Bioreactive-glass-coated hip prostheses were implanted in dogs for periods of time ranging from 3 to 17 months. The prostheses were tailor-made for each animal through the use of standard radiographs. However, such a procedure does not necessarily yield a close apposition between the glass layer and bone. As a result, the initial stability of the component can be lost before bone bonding is established. Secondary to this phenomenon, the micromotion can lead to a continuous disruption of the top film on the glass despite the evidence of various reaction layers on the glass surface.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 961-968 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Polyurethanes are finding increasing utilization in biomedical applications. Recently, the reported finding of methylene dianiline (4,4′-diaminodiphenylmethane, MDA) in the aqueous extracts of autoclaved 4,4′-diphenylmethane diisocyanatebased polyurethanes promoted our investigation of the origin and extent of extractable methylene dianiline in polyurethanes. A high-pressure liquid chromatography procedure using precolumn derivatization is utilized to selectively monitor the appearance of this diamine in the aqueous extracts of polyurethanes subjected to water immersion, heat aging, and various sterilization techniques. No MDA was found in the aqueous extracts of the treated polyurethane except for the case of prolonged steam autoclaving. The appearance of 3-5 ppb MDA in the extract under these conditions is attributed to hydrolysis of the polymer. The stability of the polyurethanes under most conditions renders these materials useful in biomedical applications.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The binding of metal ions from salts and from corrosion products of 316 LVM stainless steel and MP-35 to blood cells and serum proteins was studied in vitro. In the first series of experiments, metal salts were added to whole blood and then the blood separated into red cells, white cells, and serum. Nickel from nickel chloride or corrosion products of stainless steel bound in very small quantities to blood cells. Cobalt from cobalt chloride bound to both red cells and white cells. Chromium from chromic chloride (Cr3+) bound to cells in very small quantities whereas chromium from potassium dichromate (Cr6+) and corrosion products showed very high to binding to red cells and some binding to white cells. In a second series of experiments the blood was separated into its components and then the metal salts were added and the binding pattern was identical. In a third series of experiments serum which had interacted with the metal salts or corrosion products was separated into its components by isolectric focusing on polyacrylamide gels. Almost all of the metal, whatever the source, was detected in the albumin region of the gels indicating strong binding to albumin. These studies on the cell and protein binding of the metals help to explain the dissemination of corrosion products from the site of the implant and subsequent systemic responses by some individuals.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In an attempt to find an alternative procedure to the preclotting of porous textile vascular prostheses, the feasibility of an albumin coating and ethanol preservation technique has been evaluated by implanting albuminated polyester prostheses as substitutes in the thoracic aorta of dogs. Nine different grafts representing woven, knitted, and velour constructions were implanted for periods ranging from 4 h to 6 months. At the sacrifice, the grafts were excized for measurement of the thrombogenicity of the flow surface, for pathological examination by light microscopy and SEM, and for quantifying the changes in the textile structure during implantation. Also the kidneys were removed and examined for infarcts caused by trapped circulating emboli. The healing characteristics of the nine different grafts proved similar and followed the same sequence of events as preclotted control grafts. The albumin coating and ethanol preservation resulted in a somewhat slower rate of healing. Yet, given sufficient time, a more completely healed graft was achieved as evidenced by the presence of endothelial-like cells throughout the length of the graft. In addition, the albumin is believed to reinforce the textile structure by reducing the tendency to stretch and dilate in vivo.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 1115-1124 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: For intravascular implantation, a biofunctional surface seems to retard surface thrombosis upon synthetic materials. Prostaglandins, like PGI2, PGE1, and PGD2, etc., are believed to stimulate membrane-bound adenyl cyclase and thereby raise intracellular levels of c-AMP within platelets, which inhibit platelet adhesion and aggregation. A new procedure is suggested for the immobilization of prostaglandin E1 on an albuminated polymer matrix, through glutaraldehyde coupling. Materials thus prepared show dramatic antiplatelet effects, with regard to platelet adhesion, when compared with albumin-immobilized surfaces. The affinity of various modified surfaces toward platelet adhesion is studied, using washed platelets suspended in Tyrode's solution. Octane contact angle studies are used to develop an understanding of the varied nature of bound substrates at equilibrium on polymer surfaces. These are studied at the solid/liquid interface, which is closest to in vivo conditions. The plasma recalcification time demonstrates the anticoagulant properties of various surfaces. A possible role of PGE1 in reducing platelet activity in the presence and absence of vitamin C is discussed. This technique may be used in the development of nonthrombogenic surfaces on existing biomedical polymers. Simultaneous pharmaceutical modification of the blood with vitamin C may enhance the blood compatibility of the surface.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 171-175 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: One cause of aseptic loosening of cemented total hip arthroplasty is mechanical weakness at the interface between the metal stem and the cured bone cement. Adhesive acrylic bone cement containing 4-methacryloyloxyethyl trimellitate anhydride (4-META) was applied as a metal coating material to increase the strength of the cemented fixation. The 4-META cement has 2-3 times greater tensile bond strength to metals than does commercial acrylic bone cement. The shear strength of the coated metals fixed with bone cement was approximately 4 times greater in SUS-304 and 3 times greater in titanium (Ti) alloy than those of uncoated metals, and this strength did not decrease after 1 week's immersion in saline. The coating process using the 4-META cement can be performed at normal room temperature, so that metal stems for bone cement fixation could be coated during the course of an operation resulting in potentially improved results of total hip arthroplasty. © 1997 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 201-209 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Adhesion of yeasts and bacteria to silicone rubber is one of the first steps in the biodeterioration of silicone rubber voice prostheses. In this paper, adhesion of two streptococcal, staphylococcal, Candida albicans and Candida tropicalis strains, isolated from explanted voice prostheses was investigated to silicone rubber with and without a salivary conditioning film in a parallel-plate flow chamber. Within each microbial pair of one species, the strain with the most negative zeta potential adhered most slowly to negatively charged silicone rubber. No other clear relationships were obvious between adhesion to silicone rubber and microbial zeta potentials or cell-surface hydrophobicities, as by water contact angles. A 1.5-h adsorbed salivary conditioning film appeared to possess components, presumably albumin and lysozyme, slowing down the deposition of the yeasts and some of the streptococcal and staphylococcal isolates. In addition, microbial adhesion in a stationary end point was generally lower to silicone rubber with an adsorbed salivary conditioning film than without one. Nearly all microorganisms adhering to an adsorbed salivary conditioning film, yeasts as well as bacteria, were stimulated to detach by the passage of an air bubble through the chamber, but microorganisms adhering directly to the silicone rubber, especially C tropicalis strains, detached in far lower numbers under the influence of a passing air bubble. The present observations are in agreement with clinical in vivo findings that in patients with reduced saliva production after radiotherapy, the device life of the voice prosthesis is significantly shortened and suggests that isolated salivary components might be used as an anti-adhesive. © 1997 John Wiley & Sons, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 1-8 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We examined the influence of aging on the implant-bone interface of titanium implants inserted transcortically and extending into the medullary canal of rat tibiae, and quantitatively assessed the differences in bone reaction using an image processing system. Three groups of 15 female rats, aged 6 weeks (young group), 22 weeks (adult group), and 80 weeks (old group) were used in this experiment. The animals were sacrificed 28 days after implant placement. Toluidine blue stained undecalcified sections were prepared for histological observation and image analysis, and the implant socket was observed by SEM. There was no difference in the degree of maturation of newly formed bone between the young and adult groups. Titanium implants inserted in the young and adult groups were surrounded with a bone layer. In the old group, however, there was little mature bone tissue around the implants. Quantitative evaluation indicated that the young group showed the highest, the adult group showed a slightly lower, and the old group showed the lowest percent bone contact, thickness of bone contact, and area of bone surrounding the implant. © 1997 John Wiley & Sons, Inc.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...