ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Occupational Health and Environmental Toxicology
  • Wiley-Blackwell  (111)
  • Annual Reviews
  • 2005-2009
  • 1990-1994  (63)
  • 1980-1984  (48)
  • 1994  (63)
  • 1984  (48)
Collection
Publisher
  • Wiley-Blackwell  (111)
  • Annual Reviews
Years
  • 2005-2009
  • 1990-1994  (63)
  • 1980-1984  (48)
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 483-487 
    ISSN: 0197-8462
    Keywords: ELF magnetic field ; dosimetry ; electric field probe ; tissue conductivity ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Measuring internal induced electric fields in animals with a miniaturized probe involves a potential error related to the difference between the hole conductivity (σh) and the surrounding tissue conductivity (σt). Theory was developed to describe this phenomenon and checked by probe measurements in agar-filled petri dishes. The value measured in the hole is 2σt/(σh + σt) times the actual field in the tissue. For example, a probe hole in muscle, which is filled with blood, could yield a measurement only about 22% of the true value in the muscle. This potential source of error can be mitigated to some extent by not actually cutting a hole, by using a low-conductivity (e.g., 0.2 S/m) coupling medium in the hole, or by ensuring contact between the probe's electrodes and the tissue. © 1994 Wiley-Liss, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 513-518 
    ISSN: 0197-8462
    Keywords: subchronic exposure ; rotating magnetic fields ; neuroendocrine hormone ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: We exposed rats to circularly polarized 50 Hz magnetic fields to determine if plasma testosterone concentration was affected. Previous experiments indicate that magnetic fields suppress the nighttime rise in melatonin, suggesting that other neuroendocrine changes might occur as well. Male Wistar-King rats were exposed almost continuously for 6 weeks to magnetic flux densities of 1,5, or 50 μT. Blood samples were obtained by decapitation at 12:00 h and 24:00 h. Plasma testosterone concentration showed a significant day-night difference, with a higher level at 12:00 h when studied in July and December, but the day-night difference disappeared when concentrations were studied in April. In three experiments, magnetic field exposure had no statistically significant effect on plasma testosterone levels compared with the sham-exposed groups. These findings indicate that 6 weeks of nearly continuous exposure to circularly polarized, 50 Hz magnetic fields did not change plasma testosterone concentration in rats. © 1994 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0197-8462
    Keywords: magnetic fields ; micelles ; photolysis ; triplet radical pair ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The influence of 60-Hz magnetic fields on free radical reactions can be quantitatively predicted from the knowledge of the effect of static fields on free radical behavior. Studies of radical reactions in micellar systems show that the behavior under a 60-Hz field is identical to that under a static field at any given point in time. © 1994 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 519-529 
    ISSN: 0197-8462
    Keywords: electromagnetic fields ; occupational hazards ; fetal development ; carcinogenesis ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Given the current interest in potential carcinogenic and developmental effects of exposure to extremely-low-frequency electromagnetic fields, there is a need to identify cohorts of exposed female workers for future epidemiologic investigations. This study was designed to test the hypothesis that nurses working in neonatal intensive care units (NICU) may be significantly exposed to power-frequency magnetic fields. An electromagnetic field monitor was used to measure magnetic fields at distances of 5, 15, 30, and 60 cm from the surfaces of each device used in the NICU. Six female nurses assigned to the NICU (the “exposed” group) and six female nurses working in the normal newborn nursery (the “referent” group) wore EMDEX dosimeters for the entire duration of their 12 h shifts. An investigator kept a detailed log of each NICU subject's whereabouts for the first one-third of her shift. Magnetic fields at 5 cm from the front (defined by the nurses' usual work area) of the NICU devices ranged from less than 0.1 to 114 μT and in all cases decreased considerably with increasing distance. The geometric mean of the shift-time-weighted average exposure of the NICU nurses was 0.17 μT compared with 0.11 μT for the normal newborn nurses. The percentage of time when subjects were exposed to magnetic fields of 0.4 μT or greater ranged from 5.8% to 15.6% for the NICU nurses, 0.4% to 2.9% for five of the comparison group nurses, and was 9.4% for one of the normal newborn nurses with unidentified aberrantly high exposures. Log data revealed that the vast majority of observed peaks among NICU nurses occurred while subjects were in close proximity to infant bed units. We conclude that NICU nurses represent one female-intensive job sector with intermittent high exposures to ELF magnetic fields and encourage larger exposure studies of nurses in a variety of medical settings. © 1994 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0197-8462
    Keywords: cancer promotion ; initiation ; tumor incidence ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The purpose of this study was to investigate the effects of 2.45 GHz microwave (MW) radiation on dimethylhydrazine (DMH)-induced colon cancer in mice. The subjects were 115 Balb/c mice 4 weeks of age. The animals were divided into group A (control), group B (DMH), group C (DMH + MW), and group D [DMH + 12-O-tetradecanoylphorbol-13-acetate (TPA)]. Radiation (10 mW/cm2) was delivered dorsally with the E field parallel to the mouse's long body axis in an anechoic chamber. Radiations were administered 3 hr daily, 6 days per week, over a period of 5 months. The average SAR was estimated to be 10-12 W/kg. During the course of radiation treatments, DMH was injected once per week. The tumor promoter TPA was administered once per week for 10 weeks, from the third week on, after the initial treatment. The incidence of tumors did not significantly differ between the three test groups (groups B, C, and D; P 〉 0.25). However, the number of tumors, the size of the tumors, and the incidence of protuberant and infiltrative types in tumor-bearing animals were higher in group D compared to groups B and C (P 〈 0.05). No difference was found between groups B and C (P 〉 0.25). The study indicates that 2.45 GHz microwave radiation at 10 mW/cm2 power density did not promote DMH-induced colon cancers in young mice. The study also showed that TPA could accelerate colon tumor production if a tumor was initiated. © 1994 Wiley-Liss, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 217-238 
    ISSN: 0197-8462
    Keywords: AC/DC magnetic fields ; mathematical models ; ionic resonance ; IPR ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Theoretical models proposed to date have been unable to clearly predict biological results from exposure to low-intensity electric and magnetic fields (EMF). Recently a predictive ionic resonance model was proposed by Lednev, based on an earlier atomic spectroscopy theory described by Podgoretskii and Podgoretskii and Khrustalev. The ion parametric resonance (IPR) model developed in this paper corrects mathematical errors in the earlier Lednev model and extends that model to give explicit predictions of biological responses to parallel AC and DC magnetic fields caused by field-induced changes in combinations of ions within the biological system. Distinct response forms predicted by the IPR model depend explicitly on the experimentally controlled variables: magnetic flux densities of the AC and DC magnetic fields (Bac and Bdc, respectively); AC frequency (fac); and, implicitly, charge to mass ratio of target ions. After clarifying the IPR model and extending it to combinations of different resonant ions, this paper proposes a basic set of experiments to test the IPR model directly which do not rely on the choice of a particular specimen or endpoint. While the fundamental bases of the model are supported by a variety of other studies, the IPR model is necessarily heuristic when applied to biological systems, because it is based on the premise that the magnitude and form of magnetic field interactions with unhydrated resonant ions in critical biological structures alter ion-associated biological activities that may in turn be correlated with observable effects in living systems. © 1994 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 239-260 
    ISSN: 0197-8462
    Keywords: AC/DC magnetic fields ; neurite outgrowth ; nerve growth factor ; IPR ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A companion paper describes a predictive ion parametric resonance (IPR) model of magnetic field interactions with biological systems based on a selective relation between the ratio of the flux density of the static magnetic field to the AC magnetic field and the charge-to-mass ratio of ions of biological relevance. Previous studies demonstrated that nerve growth factor (NGF)-stimulated neurite outgrowth (NO) in PC-12 cells can be inhibited by exposure to magnetic fields as a function of either magnetic field flux density or AC magnetic field frequency. The present work examines whether the PC-12 cell response to magnetic fields is consistent with the quasiperiodic, resonance-based predictions of the IPR model. We tested changes in each of the experimentally controllable variables [flux densities of the parallel components of the AC magnetic field (Bac) and the static magnetic field (Bdc) and the frequency of the AC magnetic field] over a range of exposure conditions sufficient to determine whether the IPR model is applicable. A multiple-coil exposure system independently controlled each of these critical quantities. The perpendicular static magnetic field was controlled to less than 2 mG for all tests. The first set of tests examined the NO response in cells exposed to 45 Hz Bac from 77 to 468 mG(rms) at a Bdc of 366 mG. Next, we examined an off-resonance condition using 20 mG Bdc with a 45 Hz AC field across a range of Bac between 7.9 and 21 mG(rms). Finally, we changed the AC frequency to 25 Hz, with a corresponding change in Bdc to 203 mG (to tune for the same set of ions as in the first test) and a Bac range from 78 to 181 mG(rms). In all cases the observed responses were consistent with predictions of the IPR model. These experimental results are the first to support in detail the validity of the fundamental relationships embodied in the IPR model. © 1994 Wiley-Liss, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994) 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 275-282 
    ISSN: 0197-8462
    Keywords: EMF ; exposure assessment ; wire codes ; 60 Hz ; epidemiology ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Wire codes, introduced by Wertheimer and Leeper as a surrogate for residential magnetic fields, divide imputed exposure into several categories based on the configurations of electrical wiring within 40 m of homes. Using the data set gathered by Savitz et al. in the Denver, Colorado, area of the United States, we determined which of the wiring attributes that contribute to Wertheimer-Leeper coding are actually associated with lowpower magnetic fields measured in bedrooms of subjects. The results led us to propose a considerably simplified three-category form of the Wertheimer-Leeper code that 1) drops the distinctions between thick and thin primary wires and between first-span and other secondary lines, 2) adds a new distinction between open (i.e., conductors not in physical contact) and spun secondaries, and 3) explains as much of the between-home variability in log-transformed bedroom fields as does the five categories of the original Wertheimer-Leeper code. The data necessary to classify residences using the modified code are considerably simpler to obtain and should lead to more reliable results. A separate reanalysis of the Denver data set of Savitz et al. shows that the modified code yields risk estimates that are both precise and markedly elevated for the highest exposure category, suggesting that this code may be useful in other studies. © 1994 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 283-291 
    ISSN: 0197-8462
    Keywords: electromagnetic field ; protein synthesis ; Escherichia coli ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Escherichia coli JM83 {F- ara Δ(lac-proAB) rpsL [φ80dΔ(lacZ)M15]} in midlog growth phase at 30 °C were exposed to 60 Hz sinusoidal magnetic field of 3 mT of nonuniform diverging flux, inducing a nonuniform electric field with a maximum intensity of 32 μV/cm using an inductor coil. Exposed and unexposed control cells were maintained at 30.8 ± 0.1 °C and 30.5 ± 0.1 °C, respectively. Quadruplicate samples of exposed and unexposed E. coli cells were simultaneously radiolabeled with 35S-L-methionine at 10 min intervals over 2 hr. Radiochemical incorporation into proteins was analyzed via liquid scintillation counting and by denaturing 12.5% polyacrylamide gel electrophoresis. The results showed that E. coli exposed to a 60 Hz magnetic field of 3 mT exhibited no qualitative or quantitative changes in protein synthesis compared to unexposed cells. Thus small prokaryotic cells (less than 2 μm × 0.5 μm) under constant-temperature conditions do not alter their protein synthesis following exposure to 60 Hz magnetic fields at levels at 3 mT. © 1994 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 293-301 
    ISSN: 0197-8462
    Keywords: sinusoidal ; weak ELF magnetic field ; cultured fetal cells ; clastogenic effect ; chromatid and chromosome gaps ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Our recent studies have shown a significant increase in the frequency of chromosomal aberrations in human amniotic cells after exposure to a sinusoidal 50 Hz, 30 μT (rms) magnetic field. To evaluate further interactions between chromosomes and electromagnetic fields, we have analyzed the effects of intermittent exposure. Amniotic cells were exposed for 72 h to a 50 Hz, 30 μT (rms) magnetic field in a 15 s on and 15 s off fashion. Eight experiments with cells from different fetuses were performed. The results show a 4% mean frequency of aberrations among exposed cells compared to 2% in sham-exposed cells. The difference is statistically significant, with P 〈 0.05 both excluding and including gaps. In another series of eight experiments, the cells were exposed in the same way but with the field on for 2 s and off for 20 s. Also in these experiments a similar increase in the frequency of chromosomal aberrations was seen, but only when the analysis included gaps. Continuous exposure for 72 h to 300 μT, 50 Hz, did not increase the frequency of chromosomal aberrations. The background electromagnetic fields at different locations within the two incubators used was carefully checked and was nowhere found to exceed 120 nT. Likewise, the background level of chromosomal aberrations in cells cultured at different locations in the incubators showed no significant interculture differences. © 1994 Wiley-Liss, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 315-328 
    ISSN: 0197-8462
    Keywords: cancer cells ; thermochemiluminescence ; dosimetry ; melanin ; microwave radiation ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Chemical and bacterial synthesis of a thermochemiluminescent polymer known as diazoluminomelanin (DALM) has been previously reported. This paper focuses on the intracellular synthesis of aminomelanin (AM) in mammalian cell lines and subsequent DALM synthesis from this core molecule. B16 melanoma cells, HL-60 myeloid leukemia cells, and RAW 264.7 macrophages show AM and DALM production. Macroscopic image analysis of HL-60 cell lysates containing DALM using the Quantitative Luminescence Imaging System (QLIS) showed increased chemiluminescence (CL) with increased microwave power input and increased temperature. This work represents a first step toward the goal of microscopic radiofrequency dosimetry of individual DALM-loaded cells using image analysis. © 1994 Wiley-Liss, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 329-336 
    ISSN: 0197-8462
    Keywords: transcription ; translation ; SV-40 ; large T-antigen ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: In its integrated form, SV-40 DNA offers an opportunity to observe the behavior of what is in effect a viral genome within a cellular genome, with transcriptional and translational products that can be clearly distinguished from those of the host cell. Exposure of SV40-transformed human fibroblasts to a 60 Hz continuous-wave sinusoidal electromagnetic (EM) field resulted in increased levels of virally derived mRNA and protein of large T-antigen. These findings provide evidence that a foreign DNA integrated into cells can be affected by EM fields under conditions known to cause increased transcripts from endogenous cellular genes. © 1994 Wiley-Liss, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 337-347 
    ISSN: 0197-8462
    Keywords: ELF magnetic fields ; exposure assessment ; epidemiology ; misclassification ; statistical power ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The development of a wire code protocol based on a study of electrical installations in Melbourne, Australia, is described. Because of very significant differences between the Melbourne power distribution system and that used in Denver, Colorado, an approach different from that used by Wertheimer and Leeper was required. A combined practical and theoretical approach was used to determine a continuous exposure index, defined as a measure of the potential for exposure due to external electrical installations. The protocol was tested on a convenient sample of 41 homes in which the field was monitored over a 12 hour overnight period. A correlation of 0.85 (95% CI 0.74-0.92, P 〈 .0001) was obtained between the measured time-weighted average and the wire coding exposure index. To assess the efficacy of the wiring configuration index, a computer simulation of a case-control study was then performed. It was concluded that, using the same basic reasoning of the Wertheimer and Leeper code, it is possible to develop a location-specific code that provides a good correlation with the residential time-weighted average and an acceptable degree of exposure misclassification. © 1994 Wiley-Liss, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 539-547 
    ISSN: 0197-8462
    Keywords: electromagnetic fields ; signal-to-noise ratio ; stochastic resonance ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The most important but still unresolved problem in bioelectromagnetics is the interaction of weak electromagnetic fields (EMFs) with living cells. Thermal and other types of noise pose restrictions in cell detection of weak signals. As a consequence, some extant experimental results that indicate low-intensity field effects cannot be accounted for, and this renders the results themselves questionable. One way out of this dead end is to search for possible mechanisms of signal amplification. In this paper, we discuss a general mechanism in which a weak signal is amplified by system noise itself. This mechanism was discovered several years ago in physics and is known, in its simplest form, as a stochastic resonance. It was shown that signal amplification may exceed a factor of 1000, which renders existing estimations of EMF thresholds highly speculative. The applicability of the stochastic resonance concept to cells is discussed particularly with respect to the possible role of the cell membrane in the amplification process. © 1994 Wiley-Liss, Inc.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 555-561 
    ISSN: 0197-8462
    Keywords: frog ; ventricular muscle ; conduction velocity ; 2,450 MHz ; microwave thermal effect ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Thirty-two frog hearts were divided into four groups and placed individually in temperature-controlled waveguides filled with Ringer's solution. The pacemaker was removed, and stimulation was provided at 0.3 Hz by three carbon-loaded Teflon electrodes located on the aorta and the ventricular muscle. Conduction velocity was measured from the difference between two action potentials. One group served as control; the three other groups were exposed for 2 h to pulsed 2,450 MHz microwave fields (10 μs, 0.001 duty cycle, 16 Hz modulation) at specific absorption rates (SARs) of 0.003, 2, and 6 W/kg, respectively. No significant difference in conduction velocity was found between the control and the exposed groups. © 1994 Wiley-Liss, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    ISSN: 0197-8462
    Keywords: ELF ; magnetic fields ; cyclotron resonance ; calcium transport ; potassium transport ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: We have investigated the effects of sinusoidal electromagnetic fields (EMF) on ion transport (Ca2+, Na+, K+, and H+) in several cell types (red blood cells, thymocytes, Ehrlich ascites tumor cells, and HL60 and U937 human leukemia cells). The effects on the uptake of radioactive tracers as well as on the cytosolic Ca2+ concentration ([Ca2+]i), the intracellular pH (pHi), and the transmembrane potentsial (TMP) were studied. Exposure to EMF at 50 Hz and 100-2000 μT (rms) had no significant effects on any of these parameters. Exposure to EMF of 20-1200 μT (rms) at the estimated cyclotron magnetic resonance frequencies for the respective ions had no significant effects except for a 12-32% increase of the uptake of 42K within a window at 14.5-15.5 Hz and 100-200 μT (rms), which was found in U937 and Ehrlich cells but not in the other cell types. © 1994 Wiley-Liss, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 589-591 
    ISSN: 0197-8462
    Keywords: dielectric measurement ; human blood ; age ; temperature ; permittivity ; conductivity ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Dielectric properties of human red blood cells (RBCs) in suspension (hematocrit 50%) from 243 healthy persons (120 males, 123 females) were measured at 25 °C in a frequency range of 1-500 MHz, with a coaxial transmission line reflection method (one-side measurement). The measuring system, controlled by an IBM-PC computer, was composed of a network analyzer (HP4195A), an impedance test adapter (HP41951-61001), a coaxial line sensor, and a temperature-controlling set. The data measured revealed a statistically significant age dependence, with a critical age of about 49 years, above which permittivity and conductivity of human RBCs in suspension decreased significantly. © 1994 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 0197-8462
    Keywords: magnetic fields ; exposure system ; stray fields ; Merritt coils ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Exposure systems that provide good magnetic field uniformity, minimum stray fields, and minimal heating, vibration, and hum, as well as capability for true sham exposure in which current flows in the coils, are needed to determine rigorously the biological effects of weak magnetic fields. Designs based on acrylic polymer coil support structures and twisted pair bifilary coil windings were employed to fabricate several different systems for the exposure of laboratory animals and cell cultures to magnetic fields. These systems exhibit excellent performance characteristics in terms of exposure field uniformity, stray field containment, and exposure field cancellation in the sham exposure mode. A custom-written computer program was used to determine the best arrangement for coils with regard to field uniformity in the exposure volume and stray field containment. For in vivo exposures, modules were made up of four Merritt four-coil sets, built into a single structure and positioned to form an octapole with fields directed in the horizontal plane. For in vitro applications, two different coil configurations were selected to produce the vertical fields required. A quadrupole system, comprising modules consisting of two Merritt four-coil sets arranged side by side to limit stray fields, was built as a prototype. In the second configuration, one Merritt four-coil set was positioned inside the other to form a concentric coil set. In both in vitro systems, exposure chambers were connected to remote commercial incubators in order to reduce ambient magnetic fields in the exposure volume. An active field cancellation circuit was developed for reducing ambient AC magnetic fields in the in vitro sham exposure chamber, when necessary. These design and fabrication approaches provide systems that offer uniform field exposures and excellent stray field containment when needed and are portable, washable, and relatively inexpensive. © 1994 Wiley-Liss, Inc.This article is a US Government work and, as such, is in the public domain in the United States of America.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 593-597 
    ISSN: 0197-8462
    Keywords: magnetic fields ; AMEX ; average magnetic field exposure system ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Two types of dosimeters for measuring human exposure to 60 Hz magnetic fields were compared. Fifty adults wore the single-axis, wrist model AMEX (average magnetic field exposure system) and the triple axis, hip-pocket or pouch model AMEX-3D meters for 2 days. Ninety-six percent of the tests were accomplished without apparent dosimeter failure. The average root mean square magnetic flux density measurements with the AMEX3D (mean = 0.10 μT, S.D. = 0.07, range = 0.03 - 0.31) were significantly higher than with the AMEX meter (mean = 0.07 μT, S.D. 0.05, range = 0.02 - 0.27 μT) (t test, P 〈 0.01). There was substantial correlation between the AMEX and the AMEX-3D measurements (Pearson's correlation coefficient = 0.65, P 〈 0.01) but poor concordance (Intraclass correlation coefficient = - 0.25). These results suggest that there is a wide variation in exposure to extremely low frequency magnetic fields in the population. Magnetic field measurements with the AMEX-3D are nearly always higher than with the AMEX dosimeters. Caution is advised when comparing magnetic field measurements made with different types of dosimeters. © 1994 Wiley-Liss, Inc.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994) 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 1-1 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 1-2 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 2-2 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 3-4 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 5-19 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 53-65 
    ISSN: 0197-8462
    Keywords: intermittents ; transients ; EMF ; electric power ; ground currents ; exposure assessment ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The current through the residential grounding circuit is an important source for magnetic fields; field variations near the grounding circuit accurately track fluctuations in this ground current. In this paper, a model is presented which permits calculation of the range of these fluctuations. A discrete network model is used to simulate a local distribution system for a single street, and a statistical model to simulate unbalanced currents in the system. Simulations of three-house and ten-house networks show that random appliance operation leads to ground current fluctuations which can be quite large, on the order of 600%. This is consistent with measured fluctuations in an actual house. © 1994 Wiley-Liss, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 21-32 
    ISSN: 0197-8462
    Keywords: ELF ; EMF ; exposure assessment ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Research that has attempted to examine the relationship between work exposures to magnetic fields and health effects has suffered from limited exposure information. Power-frequency electric and magnetic (EM) field exposures vary substantially between industries, occupations, and individuals. In this study magnetic field data were collected for a variety of occupational categories within an electric utility. The sampling procedures emphasized craft occupations that were presumed to have higher exposures to magnetic fields. The objectives were to provide better exposure information for an ongoing cancer mortality study, examine the relationship between different summary measures of magnetic field exposure, and make available descriptive information useful for exposure reduction and worker education. Principal components analysis (PCA) and Varimax rotation were used to explore the relationships between the different summary measures among all utility workers and among the subset of electrical craft occupations. Discriminant analysis was used to assess summary measures of exposure that differentiated occupational groups. Measurements for 770 days generated a total of 42378 hours of magnetic field data. Eleven summary indices of exposure were calculated for specific occupational groups. These include arithmetic mean, geometric mean, median, 95th and 99th percentiles, and fraction of measurements exceeding .5, 1, 5, 10, and 100 μT. Electrical craft occupations had higher work exposures than non-craft occupations. Electricians and substation operators had the highest exposures among craft occupations.We identified subsets of summary measures that were intercorrelated. The first PCA axis included the geometric mean, median, and the fractions exceeding 0.5 and 1.0 μT. This set of measures also were best at discriminating occupational groups. The relevance of these findings may become more important if consistent associations are found between particular occupations and disease and particular occupations and magnetic field summary measures. Further research is needed to evaluate these exposure assessment findings. © 1994 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    ISSN: 0197-8462
    Keywords: exposure assessment ; environmental magnetic fields ; residential magnetic fields ; epidemiological protocol ; wire codes ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A study was carried out in 1990 to guide the development of a protocol for assessing residential exposures of children to time-weighted-average (TWA) power-frequency magnetic fields. The principal goal of this dosimetry study was to determine whether area (i.e., spot and/or 24 h) measurements of power-frequency magnetic fields in the residences and in the schools and daycare centers of 29 children (4 months through 8 years of age) could be used to predict their measured personal 24-h exposures. TWA personal exposures, measured with AMEX-3D meters worn by subjects, were approximately log-normally distributed with both residential and nonresidential geometric means of 0.10 μT (1.0 mG). Between-subjects variability in residential personal exposure levels (geometric standard deviation of 2.4) was substantially greater than that observed for nonresidential personal exposure levels (1.4). The correlation between log-transformed residential and total personal exposure levels was 0.97. Time-weighted averages of the magnetic fields measured in children's bedrooms, family rooms, living rooms, and kitchens were highly correlated with residential personal exposure levels (r = 0.90). In general, magnetic field levels measured in schools and daycare centers attended by subjects were smaller and less variable than measured residential fields and were only weakly correlated with measured nonresidential personal exposures. The final measurement protocol, which will be used in a large US study examining the relationship between childhood leukemia and exposure to magnetic fields, contains the following elements: normal- and low-power spot magnetic field measurements in bedrooms occupied by subjects during the 5 years prior to the date of diagnosis for cases or the corresponding date for controls; spot measurements under normal and low power-usage conditions at the centers of the kitchen and the family room; 24-h magnetic-field recordings near subjects' beds; and wire coding using the Wertheimer-Leeper method. © 1994 Wiley-Liss, Inc. This article is a US Government work and, as such, is in the public domain in the United States of America.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984) 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 1-12 
    ISSN: 0197-8462
    Keywords: video display unit (VDU) ; electric field ; ELF ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Electric fields produced by a selection of video display units have been measured over a frequency range from DC to 1 MHz. The magnitude and the time variation of the electric fields were both recorded by means of a single broadband capacitive sensor located on the surface of a simple simulation of the human body. The electric field at a given location was found to be the sum of three discrete components, each having a different spatial and time variation. These components are produced by, respectively, the charged CRT screen, the flyback transformer, and the low-voltage circuitry. For the units tested, operator exposures are substantially below the limits of existing workplace guidelines.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 13-30 
    ISSN: 0197-8462
    Keywords: preoptic temperature ; thermode ; behavioral thermoregulation ; 2,450-MHz CW microwaves ; brain thermostat ; squirrel monkey ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: This study probed the mechanisms underlying microwave-induced alterations of thermoregulatory behavior. Adult male squirrel monkeys (Saimiri sciureus), trained to regulate the temperature of their immediate environment (Ta) behaviorally, were chronically implanted with Teflon reentrant tubes in the medical preoptic/anterior hypothalamic area (PO/AH), the brainstem region considered to control normal thermoregulatory processes. A Vitek temperature probe inserted into the tube measured PO/AH temperature continuously while changes in thermoregulatory behavior were induced by either brief (10-min) or prolonged (2.5-h) unilateral exposures to planewave 2,450-MHz continuous wave (CW) microwaves (E polarization). Power densities explored ranged from 4 to 20 mW/cm2 (rate of energy absorption [SAR] = 0.05 [W/kg]/[mW/cm2]). Rectal temperature and four representative skin temperatures were also monitored, as was the Ta selected by the animal. When the power density was high enough to induce a monkey to select a cooler Ta (8 mW/cm2 and above), PO/AH temperature rose ∼ 0.3°C but seldom more. Lower power densities usually produced smaller increases in PO/AH temperature and no reliable change in thermoregulatory behavior. Rectal temperature remained constant while PO/AH temperature rose only 0.2-0.3°C during 2.5-h exposures at 20 mW/cm2 because the Ta selected was 2-3°C cooler than normally preferred. Sometimes PO/AH temperature increments greater than 0.3°C were recorded, but they always accompanied inadequate thermoregulatory behavior. Thus, a PO/AH temperature rise of 0.2-0.3°C, accompanying microwave exposure, appears to be necessary and sufficient to alter thermoregulatory behavior, which ensures in turn that no greater temperature excursions occur in this hypothalamic thermoregulatory center.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 63-70 
    ISSN: 0197-8462
    Keywords: hyperthermia ; microwaves ; brain ; ATP ; CP ; energy metabolism ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The effects of hyperthermia, alone and in conjunction with microwave exposure, on brain energetics were studied in anesthetized male Sprague-Dawley rats. The effect of temperature on adenosine triphosphate concentration [ATP] and creatine phosphate concentration [CP] was determined in the brains of rats that were maintained at 35.6, 37.0, 39.0, and 41.0°C. At 37, 39, and 41°C brain [ATP] and [CP] were down 6.0, 10.8, and 29.2%, and 19.6, 28.7, and 44%, respectively, from the 35.6°C control concentrations. Exposure of the brain to 591-MHz radiation at 13.8 mW/cm2 for 0.5, 1.0, 3.0, and 5.0 min caused further decreases (below those observed for 30°C hyperthermia only) of 16.0, 29.8, 22.5, and 12.3% in brain [ATP], and of 15.6, 25.1, 21.4, and 25.9% in brain [CP] after 0.5, 1.0, 3.0, and 5.0 min, respectively. Recording of brain reduced nicotinamide adenine dinucleotide (NADH) fluorescence before, during, and after microwave exposure showed an increase in NADH fluorescence during microwave exposure that returned to preexposure levels within 1 min postexposure. Continuous recording of brain temperatures during microwave exposures showed that brain temperature varied between -0.1 and +0.05°C. Since the microwave exposures did not induce tissue hyperthermia, it is concluded that direct microwave interaction at the subcellular level is responsible for the observed decrease in [ATP] and [CP].
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 117-129 
    ISSN: 0197-8462
    Keywords: ELF ; electric fields ; exposure systems ; biological effects ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A system is described that uses an oscillating magnetic field to produce power-frequency electric fields with strengths in excess of those produced in an animal or human standing under a high-voltage electric-power transmission line. In contrast to other types of exposure systems capable of generating fields of this size, no electrodes are placed in the conducting growth media: the possibility of electrode contamination of the exposed suspension is thereby eliminated. Electric fields in the range 0.02-3.5 V/m can be produced in a cell culture with total harmonic distortions less than 1.5%. The magnetic field used to produce electric fields for exposure is largely confined within a closed ferromagnetic circuit, and experimental and control cells are exposed to leakage magnetic flux densities less than 5 μT. The temperatures of the experimental and control cell suspensions are held fixed within ±0.1°C by a water bath. Special chambers were developed to hold cell cultures during exposure and sham exposure. Chinese hamster ovary (CHO) cells incubated in these chambers grew for at least 48 h and had population doubling times of 16-17 h, approximately the same as for CHO cells grown under standard cell-culture conditions.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 147-164 
    ISSN: 0197-8462
    Keywords: DC and 60-Hz magnetic fields ; animal behavior ; memory retention ; locomotor activity ; pentylenetetrazole sezure threshold ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Behavioral measures were evaluated in adult CD-1 and LAF-1 mice continuously exposed for 72 h to a 1.5-Tesla (1 T = 104 Gauss) homogeneous DC magnetic field, and in LAF-1 mice continuously exposed for 72 h to a sinusoidal 60-Hz, 1.65-mT (rms) homogeneous AC field. Three types of behavioral tests were employed: (1) Memory of an electroshock-motivated passive avoidance task was assessed in animals that had been trained immediately prior to the field exposure. The strength of memory was varied either by altering the strength of the electric footshock during training, or by administering a cerebral protein synthesis inhibitor, anisomycin, at the time of training. (2) General locomotor activity was measured using a quadrant-crossing test immediately after termination of the magnetic field exposure. (3) Sensitivity of the experimental subjects to the seizure-inducing neuro-pharmacological agent, pentylenetetrazole, was assessed immediately after the field exposure on the basis of three criteria: (a) the percentage of subjects exhibiting a generalized seizure, (b) the mean time to seizure, and (c) the mean seizure level. The results of these studies revealed no behavioral alterations in exposed mice relative to controls in any of the experimental tests with the 1.5-T DC field or the 60-Hz, 1.65-mT (rms) AC field.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 203-211 
    ISSN: 0197-8462
    Keywords: microwaves ; pentobarbital ; hypothermia ; exposure orientation ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Two series of experiments were performed to study the effects of acute exposure (45 min) to 2,450-MHz circularly polarized, pulsed microwaves [1 mW/cm2, 2-μs pulses, 500 pps, specific absorption rate (SAR) 0.6 W/kg] on the actions of pentobarbital in the rat. In the first experiment, rats were irradiated with microwaves and then immediately injected with pentobarbital. Microwave exposure did not significantly affect the extent of the pentobarbital-induced fall in colonic temperature. However, the rate of recovery from the hypothermia was significantly slower in the microwave-irradiated rats and they also took a significantly longer time to regain their righting reflex. In a second experiment, rats were first anesthetized with pentobarbital and then exposed to microwaves with their heads either pointing toward the source of microwaves (anterior exposure) or pointing away (posterior exposure). Microwave radiation significantly retarded the pentobarbital-induced fall in colonic temperature regardless of the orientation of exposure. However, the recovery from hypothermia was significantly faster in posterior-exposed animals compared to those of the anterior-exposed and sham-irradiated animals. Furthermore, the posterior-exposed rats took a significantly shorter time to regain their righting reflex than both the anterior-exposed and sham-irradiated animals.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 213-220 
    ISSN: 0197-8462
    Keywords: microwaves ; ethanol ; hypothermia ; fluid consumption ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Microwave irradiation of rats by circularly polarized, 2,450-MHz, pulsed waves (2-μs pulses; 500 pps) was performed in waveguides to determine effects on ethanol-induced hypothermia and on ethanol consumption. Rats injected intraperitoneally with ethanol (3 g/kg in a 25% v/v water solution) immediately after 45 min of microwave irradiation exhibited attenuation of the initial rate of fall in body temperature, which was elicited by the ethanol, but exhibited no significant difference in maximal hypothermia as compared with that of sham-irradiated rats. Microwave irradiation did not affect the consumption of a 10% sucrose (w/v) solution by water-deprived rats. However, it enhanced the consumption of a solution of 10% sucrose (w/v) + 15% ethanol (v/v) by water-deprived animals. These results were obtained at a specific absorption rate (SAR) of 0.6 W/kg, which rate of energy dosing would require a power density of 3-6 mW/cm2 if exposure of the animals had occurred to a 12-cm plane wave.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984) 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    ISSN: 0197-8462
    Keywords: brain tissue ; radiofrequency (RF) radiation ; dosmetry ; calcium ions ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: This report describes some experimental measurements of the internal field levels induced within isolated chick-forebrains irradiated at 50, 147, and 450 MHz, under essentially the same conditions as those used in the in vitro calcium-ion efflux experiments. Ratios of incident power at 50/147 MHz and 147/450 MHz that are needed to establish the same probe output are given and comparisons made with values predicted by different spherical models. Data predicted by the layered-sphere model were found to be in close agreement with measured values for the 50/147-MHz ratio. Agreement for the 147/450-MHz ratio was poorer.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 323-330 
    ISSN: 0197-8462
    Keywords: pulsed microwaves ; rat ; blood-brain barrier ; 86Rb permeability ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Microwaves (pulsed, 2,450 MHz) at an average power density of 3 W/cm2 were applied directly to the head for 5, 10, or 20 min, producing a peak specific absorption rate of 240 W/kg in the brain, which, after a 10-min exposure, resulted in brain temperatures in excess of 43°C. A bolus of 86Rb in isotonic saline was injected intravenously and an arterial sample was collected for 20 s to determine cardiac output. Compared with unexposed controls, uptake of 86Rb increased most in those regions directly in the path of the irradiation, namely, the occipital and parietal cortex, as well as the dorsal hippocampus, midbrain, and basal ganglia. In a separate group of animals, regional brain-vascular spaces were found to increase with brain temperature. These results support previous observations indicating that reliably demonstrable increases of blood-brain barrier permeability are associated with intense, microwave-induced hyperthermia, and that the observed changes are not due to field-specific interaction.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 341-351 
    ISSN: 0197-8462
    Keywords: microwaves ; amplitude modulation ; human lymphocytes ; protein kinase ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Cultures of human tonsil lymphocytes were exposed in a Crawford cell to a 450-MHz field (peak envelope intensity 1.0 mW/cm2), sinusoidally amplitude modulated (depth 80%) at frequencies between 3 and 100 Hz for periods up to 60 min. The Crawford cell was housed in a temperature-controlled chamber (35°C) and control cultures were placed in the same chamber. Activity of cAMP-dependent protein kinase relative to controls remained unaltered by fields modulated at 16 or 60 Hz with exposures of 15, 30, and 60 min. By contrast, total non-cAMP-dependent kinase activity fell to less than 50% of unexposed control levels after 15 and 30 min exposures, but, despite continuing field exposure, returned to control or preexposure levels by 45 and 60 min. A smaller reduction (20-25%) also occurred with 60-Hz modulation and was also restricted to exposure durations of 15 and 30 min. CW 450-MHz fields were without effect. Reduced enzyme activity occurred with 16-, 40-, and 60-Hz modulation frequencies, but not with 3-, 6-, 80-, or 100-Hz modulation. The specific identity of this kinase is unknown. This rapid but transient reduction in lymphocyte protein kinase activity restricted to modulation frequencies between 16 and 60 Hz and to less than 30 min exposure is consistent with „windowing“ with respect to modulation frequency and exposure duration.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 0197-8462
    Keywords: electric fields ; ELF ; 60 Hz ; guinea pig ; dosimetry ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Short-circuit currents, surface electric fields, and axial current densities were measured in electrically grounded guinea pigs exposed to a uniform, vertical, ELF electric field. These data are 70-110% of corresponding values obtained in grounded rats exposed to the same electric field.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 399-410 
    ISSN: 0197-8462
    Keywords: magnet ; magnetic field ; tissue culture ; exposure system ; biological effects ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A magnetic field generator constructed of rare earth-cobalt magnets is proposed for examining the biological effects of static magnetic fields (less than 1 T) on tissue cultures. Important quantities of a magnetic field from a biological-effects viewpoint, ie, its strength and the product of strength and gradient, are analysed. A practical procedure for designing the generator with optimum parameters is given. Also, parameters are determined which will yield a sinusoidal spatial field distribution.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 435-441 
    ISSN: 0197-8462
    Keywords: RF fields ; muscle ; phantom tissue ; tumor ; temperature ; dielectric constant ; conductivity ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The dielectric properties of various test samples of phantom tissue were measured using an automated and temperature-controlled slotted line. The ingredients for phantom materials were determined for simulating high-water content tissue at 13.56, 27.12, 40.68, 70, 100, 200, 300, 433, 750, 915, and 2,450 MHz. The ingredients consisted of water, TX-150 (a gelling agent), sodium chloride, and polyethylene powder (200-2,450 MHz) or aluminum powder (13.56-100 MHz). The dielectric constant and conductivity of these materials at different temperatures (15, 22, 30°C) were characterized.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 447-450 
    ISSN: 0197-8462
    Keywords: calibration ; electric field ; ELF ; instrumentation ; measurement ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The influence of nearby ground planes, perturbation of surface charge distributions, and fringing fields on the electric field between parallel plates are characterized to define a parallel plate system that can be used to calibrate flat 60-Hz electric field probes.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 31-38 
    ISSN: 0197-8462
    Keywords: Characean cells ; vacuolar potential ; electromagnetic radiation ; Nitella flexilis ; Chara braunii ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Measurements were made of the small, transient offsets of vacuolar potential produced in single cells of Nitella flexilis and Chara braunii by isolated bursts of audio frequency electromagnetic radiation. The offsets increased in magnitude with decreasing frequency of the electromagnetic radiation and, below about 6 kHz, seemed to approach a lowfrequency asymptote. This frequency dependence for the offset is shown to be in accordance with a previously developed model in which the incident radiation is weakly rectified by the cell's membrane system.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 47-62 
    ISSN: 0197-8462
    Keywords: digital computer simulation ; alternating electrical field ; electromagnetic field ; biological sturcture ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A digital computer simulation has been carried out of the exposure of a cell, modeled as a multilayered spherical structure, to an alternating electrical field. Electrical and electrochemical quantities of possible biological interest can be evaluated everywhere inside the cell. A strong frequency behavior in the range 0-10 MHz has been obtained.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 79-88 
    ISSN: 0197-8462
    Keywords: circular waveguide exposure system ; radiofrequency dosimetry ; rhesus monkey ; radiofrequency exposure ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A 275-MHz exposure system, consisting of a circular waveguide irradiator and a transparent plastic animal cage, has been developed to accommodate rhesus monkeys weighing up to 15 kg. The vertically oriented waveguide is composed primarily of stainless steel and is fitted with an inner cage fabricated from a tubular section of acrylic plastic. Circularly polarized electromagnetic energy at 275 MHz, either pulsed or continuous wave (CW), can be propagated from the removable top section of the waveguide. The cage is designed to function as the monkey's permanent home. It is fitted with a lever-actuated behavioral performance device on which the monkey responds according to a predetermined schedule to obtain a daily food ration. The system can be adapted to provide for the collection of metabolic and physiologic data as well. Dosimetric measurements were conducted with six rhesus monkeys weighing 3.0-7.2 kg and with a 4-kg model. The dosimetric results show that about one-third of the net incident energy is absorbed by a subject in this system at a normalized specific absorption rate (SAR) of 0.33 (W/kg)/(mW/cm2).
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 89-99 
    ISSN: 0197-8462
    Keywords: specific absorption rate ; resonant cavity ; spheres ; Mie theory ; superposition ; thermography ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Specific absorption rates (SARs) were determined theoretically and experimentally for several spherical models of tissue exposed to electrical fields of TE101 mode in a rectangular cavity of 57.3 MHz resonant frequency. The approximate theoretical SAR can be calculated according to the Mie theory by superposition of four plane waves representing the fields excited in the cavity. The theoretical and thermographically determined SAR patterns in spheres with radii of 5, 7.5, and 10 cm and with conductivities of 0.1, 1, and 10 S/m were compared. For a sphere with radius less than 7.5 cm and conductivity less than 1 S/m, the SAR was quite uniform. When conductivity was increased to 10 S/m, the SAR patterns showed higher absorption in the periphery of the largest sphere (10-cm radius). These characteristics are important in evaluating the scaling technique of exposing a model of a human to very-high-frequency fields to obtain power absorption data in humans exposed to high-frequency or very-low-frequency fields.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 113-115 
    ISSN: 0197-8462
    Keywords: Nernst equation ; temperature derivatives ; cell membranes ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A hyperpolarized current is predicted from the Nernst equation for conditions of positive temperature derivatives with respect to time. This ion current, coupled with changes in membrane channel conductivities, is expected to contribute to a transient potential shift across the cell membrane for silent cells and to a change in firing rate for pacemaker cells.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984) 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 131-146 
    ISSN: 0197-8462
    Keywords: human ; dosimetry ; safety ; radio frequency ; high frequency ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The radiofrequency absorption rates of five male human volunteers have been measured from 3 to 41 MHz. The subjects were exposed at about 10 μW/cm2 inside a very large transverse electromagnetic (TEM) cell and never absorbed more than 1 W. Both the EKH and EHK orientations were employed under both free-space and grounded conditions. Absorption rates for the EKH orientation exceed those of the EHK orientation by 40% in free space, but only by 6% when grounded. The absorption rates for the grounded men vary with frequency, f, as f1.9 from 3 to 25 MHz and then level off at the peak. The freespace absorption rates vary as f1.7 from 3 to 18 MHz and as f2.9 from 18 to 41 MHz. The average measured absorption rates at 10 MHz exceed the average of the standard model calculations by a factor of three (for free space) or four (grounded). The average man, when exposed grounded in an EKH orientation to the maximum permitted exposure levels under ANSI standard C95.1-1982, will absorb 0.58 ± 0.14 W/kg over most of the 3 to 41-MHz frequency range. This slightly exceeds the whole-body maximum of 0.40 W/kg underlying the standard.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 193-202 
    ISSN: 0197-8462
    Keywords: bioelectricity ; bone ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A high coefficient of variation is characteristic of the bioelectric potentials recorded from living long bones. As a consequence, the data collected from animal and human experiments are difficult to use in practical ways. A distribution curve for bone bioelectric potentials has been calculated using polynomial regression analysis to process the voltage values recorded on the whole length of rabbit tibiae, with reference electrodes positioned in three different points of the bone. The distribution curve so obtained is presented to fulfill the need for a reference curve for the bioelectric potentials recorded from rabbit tibial surfaces.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 233-246 
    ISSN: 0197-8462
    Keywords: operant behavior ; observing-responses ; radiofrequency radiation ; colonic temperature ; rhesus monkeys ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Five food-deprived rhesus monkeys were exposed to 225-MHz continuous-wave, and 1.3-GHz, and 5.8-GHz pulsed radiation to determine the minimal power densities affecting performance. The monkeys were trained to press a lever (observing-response) thereby producing signals that indicated availability of food. In the presence of the aperiodically appearing food signals, a detection response on a different lever was reinforced by a food pellet. Continuous, stable responding during 60-min sessions developed and was followed by repeated exposures to radiofrequency radiation. The subjects, restrained in a Styrofoam chair, were exposed to free-field radiation while performing the task. Colonic temperature was simultaneously obtained. Observing-response performance was impaired at increasingly higher power densities as frequency increased from the near-resonance 225 MHz to the above-resonance 5.8 GHz. The threshold power density of disrupted response rate at 225 MHz was 8.1 mW/cm2; at 1.3 GHz it was 57 mW/cm2, and at 5.8 GHz it was 140 mW/cm2. These power densities were associated with reliable increases in colonic temperatures above sham-exposure levels. The mean increase was typically in the range of 1°C, and response-rate changes were not observed in the absence of concomitant temperature increases. In these experiments increase of colonic temperature was a much better predictor of behavioral disruption than was either the power density of the incident field or estimates of whole-body-averaged rates of energy absorption.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 271-282 
    ISSN: 0197-8462
    Keywords: Electric fields ; 60 Hz ; rats ; behavior ; gastrointestinal distress ; taste aversion ; behavior toxicolgy ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A measure of taste-aversion (TA) learning was used in three experiments to 1) determine whether exposure to intense 60-Hz electric fields can produce TA learning in male Sprague-Dawley rats, and 2) establish a dose-response function for the behavior in question. In Experiment 1, four groups of eight rats each were distributed into one of two exposures (69 ± 5 kV/m or 133 ± 10 kV/m) or into one of two sham-exposure groups. Conditioning trials paired 0.1% sodium saccharin in water with 3 h of exposure to a 60-Hz electric field. Following five conditioning trials, a 20-min, two-bottle preference test between water and saccharin-flavored water failed to reveal TA conditioning in exposed groups. In Experiment 2, four groups of eight rats each (34 ± 2 kV/m or 133 ± 10 kV/m and two sham-exposed groups) were treated as before. Electric-field exposure had no effect on TA learning. Experiment 3 tested for a possible synergy between a minimal dose (for TA learning) of cyclophosphamide (6 mg/kg) and 5 h of exposure to 133 ± 10 kV/m electric fields in a dark environment under conditions otherwise similar to those of Experiments 1 and 2. The results indicated no TA learning as reflected in the relative consumption of saccharin.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 305-314 
    ISSN: 0197-8462
    Keywords: Apis mellifera ; 765-kV transmission line ; E-field ; stress ; hemocytes ; hemoproteins ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Number of circulating hemocytes and hemolymph protein patterns of adult worker honey bees were analyzed as possible indicators of stress resulting from colony placement under a 765-kV transmission line. Although exposure to 55, 80, and 95 μA total induced hive current (THC) produced colony behavioral disturbance, there were no consistent effects on mean hemocyte counts at 55- or 95-μA THC. Age-dependent declines in circulating hemocyte number were similar in all exposure groups. There were no consistent differences in tube-gel electropherograms. No consistent differences were found in two-density slab-gel electropherograms based on ultrasensitive silver stain. The 67 positively charged and four negatively charged protein fractions from overwintering bees are two- to threefold more than currently reported in the literature.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 331-339 
    ISSN: 0197-8462
    Keywords: microwaves ; avian behavior ; solar energy ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Seventeen birds from 12 flocks were exposed to microwave radiation under various combinations of power density and duration; three birds from two additional flocks served as sham-exposed controls. Experiments were conducted outdoors at Manomet, Massachusetts (41°56′N, 70°35′W) under normal winter ambient temperatures. Although irradiated birds maintained their positions within a flock hierarchy with one exception, some appeared to have a change in their level of aggression after exposure.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984) 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    ISSN: 0197-8462
    Keywords: ultrahigh frequency electromagnetic fields ; evoked potentials ; amplitude modulation ; electrophysiological processes ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Pilot studies demonstrate evidence that the electrophysiological processes associated with flash stimulation of the central nervous system (CNS) of rats, as seen in the recordings of visual-evoked potentials, may also be detectable using an ultrahigh frequency electromagnetic field (UHFEMF). Patterns of amplitude modulation of an applied UHFEMF, when recorded and averaged, show strong correlations with simultaneously recorded evoked potentials. The data support the hypothesis that the UHFEMF amplitude is altered in a dynamic fashion by the tissue's electrophysiological processes that are involved with the generation of CNS electric fields.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 377-388 
    ISSN: 0197-8462
    Keywords: microwave bioeffects ; peritoneal macrophages ; viricidal macrophages ; LPS ; immunology ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Exposure of hamsters to microwave (MW) energy (2.45 GHz, 25 mW/cm2, 1 h) resulted in activation of peritoneal macrophages (PM) to a viricidal state restricting the replication of vesicular stomatitis virus (VSV). The PM from MW-exposed hamsters were viricidal as early as 1 day after exposure and remained active for 5 days. Immunization of hamsters with vaccinia virus induced viricidal PM by 3 to 4 days and they remained active for 7 days. To test the hypothesis that thermogenic MW exposure results in the release of endotoxin across the intestinal epithelium which subsequently activates PM, hamsters were injected with lipopolysaccharide (LPS) and their viricidal activity was studied. Lipopolysaccharide in vitro (0.2 μg) and in vivo (0.5 μg) activated macrophages to a viricidal state. When administered in vivo, LPS (0.5 μg) activated macrophages as early as 1 day and the activity remained for 3 days. While MW exposure of PM in vitro failed to induce viricidal activity, exposure of PM to LPS in vitro induced strong viricidal activity. This suggests that the in vivo response of PM to MW is an indirect one, which is consistent with the hypothesis that MW-induced PM viricidal activity may be mediated via LPS. In preliminary experiments, MW exposure resulted in extended survival time for hamsters challenged with a lethal dose of vesicular stomatitis virus, supporting the concept that MW-activated PM may be a useful therapeutic modality.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 443-446 
    ISSN: 0197-8462
    Keywords: stationary magnetic fields ; LAF1/J mice ; immune response ; sheep erythrocytes ; mitogen stimulation ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Humoral and cell-mediated immune responses were assayed following a 6-day exposure of LAF1/J mice to a 1.50 Tesla (1 T = 104 Gauss) stationary magnetic field. In tests of the immune response to sheep erythrocytes, the number of Jerne plaques formed by spleen lymphocytes and the level of serum IgM were not significantly different for the exposed mice in comparison with control animals. Tests for mitogen-induced lymphocyte proliferation also demonstrated no significant differences in the response of spleen lymphocytes from exposed and control groups of mice.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 451-453 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 165-172 
    ISSN: 0197-8462
    Keywords: acetylcholinesterase ; microwave ; microwave spectrophotometer-fluorometer ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The effect of 2,450-MHz pulsed microwave radiation on the enzyme activity of membranefree acetylcholinesterase was studied while the enzyme was in the microwave field. We found no significant effect of microwave radiation on enzyme activity using a wide variety of power densities, pulse widths, repetition rates, and duty cycles. This suggests that simple, direct modification by microwave energy of acetylcholinesterase structure and enzymic activity is not related to microwave alteration of acetylcholinesterase central nervous system levels.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 173-191 
    ISSN: 0197-8462
    Keywords: electromagnetic field ; surface receptors ; cell reactivation ; lectins ; phytohemagglutinin ; lymphocytes ; microelectrophoresis ; mitogenic gain ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The aggregation between lectins and lymphocyte surface receptors can be affected strongly by a low-level electric field induced in the cell suspension by a time-varying magnetic field. One of the possible mechanisms is the microelectrophoretic effect due to the electric field, which influences the distance (in the mean square sense) between charged ligands and receptors when they are about to separate. On a purely theoretical basis, it is shown that, at low frequencies, an externally induced periodic electric field always decreases the mean lifetime of ligand-receptor complexes. As a consequence, the mitogenic gain obtained by lectin addition to cell suspension is decreased. These results suggest that such a mechanism, if effective, reduces the lectin mitogenic capability and offers a way of handling similar phenomena which have been described for other biological systems.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 315-322 
    ISSN: 0197-8462
    Keywords: brain ; rat ; development ; microwaves ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Timed-pregnancy rats were exposed in a circular waveguide system starting on day 2 of gestation. The system operated at 2,450 MHz (pulsed waves; 8 μs PW; 830 pps). Specific absorption rate (SAR) was maintained at 0.4 W/kg by increasing the input power as the animals grew in size. On day 18 of gestation the dams were removed from the waveguide cages and euthanized; the fetuses were removed and weighed. Fetal brains were excised and weighed, and brain RNA, DNA and protein were determined. Values for measured parameters of the radiated fetuses did not differ significantly from those of sham-exposed fetuses. A regression of brain weight on body weight showed no micrencephalous fetuses in the radiation group when using as a criterion a regression line based on two standard errors of the estimate of the sham-exposed group. In addition, metrics derived from brain DNA (ie, cell number and cell size) showed no significant differences when radiation was compared to sham exposure. We conclude that 2,450-MHz microwave radiation, at an SAR of 0.4 W/kg, did not produce significant alterations in brain organogenesis.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 353-356 
    ISSN: 0197-8462
    Keywords: algal cells ; amplitude-modulated irradiation ; resting potential ; phase-sensitive detection ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The membrane potential of isolated cells of Chara braunii or Nitella flexilis was monitored while the cells were exposed, at nominal power densities from 2 to 1,000 W/m2, to 147-MHz radiation amplitude modulated at frequencies from 4 to 64 Hz. Phase-sensitive detection was used to seek radiation-correlated changes in the membrane potential, and none were apparent under any of the conditions used in this investigation.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    ISSN: 0197-8462
    Keywords: Characean cells ; hyperpolarizing response ; thermal electromagnetic bioeffects ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Single giant cells of the algae Chara braunii and Nitella flexilis were exposed to bursts of electromagnetic radiation (monochromatic CW, bichromatic CW, or squarewave-modulated) in the band 200-1,000 MHz while their vacuolar potentials were monitored using micropipettes. The slow hyperpolarizing response that was observed seemed to be linear in the power deposited in the vicinity of the cell, to be otherwise indifferent to irradiation frequency or modulation, and therefore to be thermal in origin.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 389-398 
    ISSN: 0197-8462
    Keywords: dosimetry ; average SAR ; 2,450-MHz ; circular waveguide ; rat ; thermogram ; calorimetry ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Average specific absorption rates (SARs) for live rats exposed in 2,450-MHz circularly polarized waveguides were estimated from the total system loss determined from measurements using five power meters, and a correction factor representing actual SAR/apparent SAR. The actual SAR was measured by twin-well calorimetry and the apparent SAR by power meters. Values were obtained for carcasses of various body masses for five orientations. The average SAR with free movement in the cages changed less than threefold as the rats grew from 200 to 700 g. The ratio of peak to average SAR in the body was less than 3. These results indicate relatively constant energy disposition in rats exposed in the circularly polarized waveguide.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 411-418 
    ISSN: 0197-8462
    Keywords: 330-MHz radiofrequency radiation ; human erythrocyte ghosts ; scanning differential microcalorimetry ; infrared spectra ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Irreversible changes in the heat capacity of human erythrocyte ghost suspensions due to the effect of 330-MHz radiofrequency radiation (at a specific absorption rate of approximately 9 mW/g) were detected by the method of scanning differential microcalorimetry. Using the data obtained from the analysis of infrared spectra of air-dried films of erythrocyte membranes, it can be postulated that the observed microcalorimetric changes are connected with the local interaction of electromagnetic radiation with the channel-forming portion of band-3 protein.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 115-131 
    ISSN: 0197-8462
    Keywords: tissue culture ; energy efficient device ; DNA synthesis ; frequency spectrum ; collagen production ; collagen synthesis ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: An energy efficient electromagnetic stimulator device for fracture healing was compared to a commercially available device in stimulating cell growth in tissue cultures. The energy efficient device, which conserves energy by using a bidirectional time-dependent magnetic wave form, and the commercially available stimulator, which uses a unidirectionaltime-dependent magnetic wave form, were tested on chick tendon fibroblasts in primary culture. Comparing non-stimulated control and cells electromagnetically stimulated with unidirectional and bidirectional waveforms showed that at the growth phase between days 2 and 3, both electrical stimulation techniques increased cell division as measured by DNA synthesis. When cells were dividing rapidly, collagen synthesis was reduced. When the cells reached the confluence there was no difference among the groups (control, unidirectionally stimulated, and bidirectionally stimulated) in terms of number of cells or collagen produced. © 1994 Wiley-Liss, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 143-161 
    ISSN: 0197-8462
    Keywords: high peak power microwaves ; response latency ; subcutaneous temperature ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Microwave evoked body movements were studied in mice. A resonant cavity was used to provide head and neck exposure of the mouse to pulsed and gated continuous wave (CW) 1.25 GHz microwaves. No difference in response to pulsed and gated CW stimuli of equal average power was found. The incidence of the microwave evoked body movements increased proportionally with specific absorption (dose) when the whole-body average specific absorption rate was at a constant level (7300 W/kg). Under a constant average specific absorption rate, the response incidence reached a plateau at 0.9 kJ/kg. For doses higher than 0.9 kJ/kg, response incidence was proportional to the specific absorption rate and reached a plateau at 900 W/kg. Body movements could be evoked by a single microwave pulse. The lowest whole-body specific absorption (SA) tested was 0.18 kJ/kg, and the corresponding brain SA was 0.29 kJ/kg. Bulk heating potentials of these SAs were less than 0.1 °C. For doses higher than 0.9 kJ/kg, the response incidence was also proportional to subcutaneous temperature increment and subcutaneous heating rate. The extrapolated absolute thresholds (0% incidence) were 1.21 °C temperature increment and 0.24 °C/s heating rate. Due to high subcutaneous heating rates, these microwaves must be perceived by the mouse as an intense thermal sensation but not a pain sensation because the temperature increment was well below the threshold for thermal pain. Results of the present study should be considered in promulgation of personnel protection guideline against high peak power but low average power microwaves. © 1994 Wiley-Liss, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 411-426 
    ISSN: 0197-8462
    Keywords: operant conditioning ; Pavlovian conditioning ; magnetic field ; detection ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Work in our laboratory has revealed autonomic and/or behavioral sensitivity of mice, rats, and a domestic fowl to extremely-low-frequency (ELF) or nominally static magnetic (B) fields at flux densities between 250 and 1700 μT (rms). To extend our work, an automated exposure and data-acquisition system was used with the technique of conditional suppression to assess behavioral sensitivity to time-varying B fields. Each of five rats was exposed aperiodically to a B field during 3 min warning periods that terminated in a brief electric shock. The difference between rates of lever pressing during B-field warning periods and rates during immediately antecedent, 3 min control periods was analyzed at frequencies of 7, 16, 30, 60, and 65.1 Hz. To produce equivalent induced voltages in the rat at each frequency, graded flux densities were established that ranged from 1900 μT at 7 Hz to 200 μT at 65.1 Hz. Analysis of differences in lever-pressing rates revealed that in a given session of testing the rats would increasingly suppress responding when exposed to a B field, but this trend was independent of frequency. This experiment provides evidence of behavioral sensitivity by a mammal to an ELF magnetic field. © 1994 Wiley-Liss, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 439-446 
    ISSN: 0197-8462
    Keywords: magnetic field ; electric appliances ; time-weighted average exposure ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Flux density and spectral measurements were carried out on magnetic fields generated by several types of motor-driven personal appliances used near the body. Among the units tested were several for which the average flux densities, as determined at the surfaces of the appliance, exceeded 0.4 mT. Time-rates-of-change (dB/dt) for several units exceeded 1000 T/s, and several units exhibited high-frequency components in the low-MHz range. Use of such appliances, although normally of short duration, can represent exposure to magnetic fields of relatively high flux density, which may also have high-frequency components. Compared to other household and commercial sources of magnetic fields, those generated by certain motor-driven personal appliances may represent a significant contribution to time-weighted average exposure and may represent an important source of local induced currents in the body. Furthermore, high-frequency transients that represent only a minor contribution to time-weighted average exposure may generate significant instantaneous induced currents. © 1994 Wiley-Liss, Inc.This article is a US Government work and, as such, is in the public domain in the United States of America.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 447-463 
    ISSN: 0197-8462
    Keywords: ELF ; EMF ; humans ; physiology ; performance ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: This human exposure study examined the relationship between field strength and biological response and tested whether the exposure levels at which the greatest effects occur differ for different endpoints. Three matched groups of 18 men each participated in two 6 h exposure test sessions. All subjects were sham exposed in one session. In the other session, each group of subjects was exposed at a different level of combined electric and magnetic field strength (low group: 6 kV/m, 10 μT; medium group: 9 kV/m, 20 μT; and high group: 12 kV/m, 30 μT). The study was performed double blind, with exposure order counterbalanced. Significant slowing of heart rate, as well as alterations in the latency and amplitude of event-related brain potential measures derived from the electro encephalogram (EEG), occurred in the group exposed to the 9 kV/m, 20 μT combined field (medium group). Exposure at the other field strength levels had no influence on cardiac measures and differential effects on EEG activity. Significant decrements in reaction time and in performance accuracy on a time estimation task were observed only in the low group. These results provide support for the hypothesis that humans may be more responsive to some combinations or levels of field strength than to others and that such differences in responsivity may depend, in part, on the endpoint of interest. © 1994 Wiley-Liss, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 465-482 
    ISSN: 0197-8462
    Keywords: dosimetry ; bone remodeling ; ELF ; electric fields ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A commercially available spreadsheet program is used on a microcomputer to calculate the induced current density and electric field patterns produced in a nonhomogeneous, anisotropic model of tissue by a localized, low-frequency magnetic field source. Specific application is made to coils used to promote the healing of bone fractures in limbs. The variation of the conductivity of the fracture gap during healing causes the induced current density pattern to change correspondingly, whereas the induced electric field remains relatively unchanged. Use of more simplified, isotropic models for the bone and for the soft tissue leads to results that differ significantly from those obtained from the full model. The magnetic field beyond the region of the coils contributes little to the induced currents in the fracture gap if the gap is located near the center of the coils. © 1994 Wiley-Liss, Inc.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 493-493 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994) 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    ISSN: 0197-8462
    Keywords: Wistar-King rats ; circularly polarized magnetic field ; long-term exposure ; recovery process ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: In our earlier paper [Kato et al. (1993): Bioelectromagnetics 14:97-106], melatonin concentration in pineal gland and blood was reported to be suppressed after exposure to a circularly polarized 50 Hz magnetic field for 6 weeks. In the present series of experiments, we investigated the time course of recovery after cessation of the exposure. Rats were exposed to a circularly polarized 50 Hz magnetic field at 1 μT for 6 weeks, and the melatonin concentration of blood of separate groups was determined at the end of the exposure and at 1 week and 4 weeks following cessation of exposure. Nocturnal melatonin concentration was reduced (P 〈 0.05) after 6 weeks of exposure. Melatonin concentration at 1 week following cessation of exposure was normal, and no further change was observed 4 weeks later. © 1994 Wiley-Liss, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 495-501 
    ISSN: 0197-8462
    Keywords: static field ; bioeffects ; growth rate ; S. cerevisiae ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: We have used a clinical magnetic resonance imager to search for the possible effects of a 1.5 T magnetic fields on the growth of the yeast Saccharomyces cerevisiae. Yeast samples were grown in nutrient broth contained in constant-temperature boxes, both in and out of the magnetic field of the imager. Growth was measured by using a hemocytometer and light microscope to calculate cell densities. Over the time span corresponding to approximately seven cell divisions, we find no convincing statistical evidence for an effect of magnetic field on cell density. © 1994 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 261-270 
    ISSN: 0197-8462
    Keywords: ELF fields ; magnetite ; thermal noise ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Adair [Bioelectromagnetics 14:1-4, 1993] writes that “the effects of 60 Hz magnetic fields of 5 μT (50 mG) or less on biological structures holding magnetite (Fe3O4) are shown to be much smaller than those from thermal agitation; hence such interactions cannot be expected to be biologically significant.” This conclusion is questioned, because it appears to be based on a model that probably has very limited validity for pertinent biological systems. Furthermore, biologically plausible parameters can be selected to show that even this particular model does not exclude biologically significant effects of 60 Hz magnetic fields below 5 μT. Reported experimental results indicate effects in mammals of 50 Hz fields at the 1 μT level. © 1994 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 263-270 
    ISSN: 0197-8462
    Keywords: frog ; heart rate ; microwaves ; electrodes ; bradycardia ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: One hundred and two isolated frog hearts were divided into ten groups and placed individually in a waveguide filled with Ringer's solution and exposed to 2,450-MHz CW radiation at 2 and 8.55 W/kg. Heart rate was recorded using one of the following methods: 3-M KCl glass electrode, ultrasound probe, tension transducer, Ringer's solution glass electrode, and a metal wire inserted in the Ringer's solution electrode. An accelerated decrease of heart rate was observed only in those groups recorded using the 3-M KCl electrode and the metal wire Ringer's solution electrode. No effect was found in the other groups. These results indicate that bradycardia in isolated hearts could be caused by electrode artifacts resulting from the intensification of electromagnetic fields.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 39-45 
    ISSN: 0197-8462
    Keywords: microwaves ; effects of mitochondria; nonionizing radiation ; mitochondrial respiration ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Liver mitochondria were exposed in vitro at 30°C to microwave radiation (2.45 GHz) during the following states of respiraton: resting, state 1; substrate dependent, state 2; ADP stimulated, state 3; and ADP depleted, state 4. At 10 or 100 mW/g, with succinate as substrate, no effect of exposure was observed on states 1-4 or the respiratory control index (state 3/state 4) of either tightly or loosely coupled mitochondria. When glutamate was used as substrate, no effects were observed at 10 mW/g. However, in the loosely coupled mitochondria the 100 mW/g exposure produced an increase in states 2 and 4 and a decrease in the respiratory control index. The results suggest that the function of loosely coupled mitochondria can be affected at high power levels of microwave radiation.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 71-78 
    ISSN: 0197-8462
    Keywords: human neuroblastoma cells ; calcium ion efflux ; microwave ; amplitude modulation ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Monolayer cultures of human neuroblastoma cells were exposed to 915-MHz radiation, with or without sinusoidal amplitude modulation (80%) at 16 Hz, at specific absorption rates (SAR) for the culture medium and cells of 0.00, 0.01, 0.05, 0.075, 0.1, 0.5, 0.75, 1.0, 1.5, 2, or 5 mW/g. A significant increase in the efflux of calcium ions (45Ca2+) as compared to unexposed control cultures occurred at two SAR values: 0.05 and 1 mW/g. Increased efflux at 0.05 mW/g was dependent on the presence of amplitude modulation at 16 Hz but at the higher value it was not. These results indicate that human neuroblastoma cells are sensitive to extremely low levels of microwave radiation at certain narrow ranges of SAR.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 101-112 
    ISSN: 0197-8462
    Keywords: 60-Hz electric fields ; rats ; behavior ; teratology ; growth ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A series of three experiments was performed to determine the effects of 30-day exposures to uniform 60-Hz electric fields (100 kV/m) on reproduction and on growth and development in the fetuses and offspring of rats. In the first experiment, exposure of females for 6 days prior to and during the mating period did not affect their reproductive performance, and continued exposure through 20 days of gestation (dg) did not affect the viability, size, or morphology of their fetuses. In the second experiment, exposure of the pregnant rat was begun on 0 dg and continued until the resulting offspring reached 8 days of age. In the third experiment, exposure began at 17 dg and continued through 25 days of postnatal life. In the second and third experiments, no statistically significant differences suggesting impairment of the growth or survival of exposed offspring were detected. In the second experiment, a significantly greater percentage of the exposed offspring showed movement, standing, and grooming at 14 days of age than among-sham-exposed offspring. There was a significant decrease at 14 days in the percentage of exposed offspring displaying the righting reflex in the second experiment and negative geotropism in the third experiment. These differences were all transient and were not found when the animals were tested again at 21 days of age. Evaluation of the reproductive integrity of the offspring of the second experiment did not disclose any deficits.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    ISSN: 0197-8462
    Keywords: behavioral teratology ; power frequency fields ; rodents ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: To investigate the potential of magnetic fields to act as a behavioral teratogen, pregnant CD1 mice were exposed or sham-exposed for all of gestation to a 50 Hz/20 mT magnetic field. Maturation of offspring was assessed using a range of standard developmental indices (eye opening, pinna detachment, hair coat, tooth eruption, sexual maturity, and weight) and simple reflexive behaviors (air righting, surface righting, forepaw grasp, cliff avoidance, and negative geotaxis). Activity and coordination levels were explored in juvenile and adult mice using an open field arena, a head-dip board, an accelerating Rotarod, and a residential activity wheel. All assessments were carried out without knowledge of exposure condition. Results from 168 sham-exposed mice from 21 litters and from 184 exposed mice from 23 litters were compared using survival analysis techniques and multivariate regression methods. Three possible field-dependent effects were found: Exposed animals performed the air righting reflex earlier (P 〈 0.01); exposed males (but not females) were significantly lighter in weight (P = 0.008) at 30 days of age; and exposed animals remained on a Rota-rod for less time as juveniles (P = 0.03). Some of these results have not been reported in other studies and may reflect spurious statistical significance, although some effect of magnetic field exposure cannot be ruled out. Overall, these results suggest that prenatal exposure to a 50 Hz magnetic field does not engender any gross impairments in the postnatal development or behavior of mice. This does not preclude such exposure affecting more subtle aspects of behavior. Published 1994 by Wiley-Liss, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 377-383 
    ISSN: 0197-8462
    Keywords: radiofrequency radiation ; amplitude modulation ; ELF ; 16 Hz ; 60 Hz ; modulation ; enolase activity ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Some neurochemical effects of low-intensity electric and magnetic fields have been shown to be nonlinear functions of exposure parameters. These effects occurred within narrow ranges of frequency and intensity. Previous studies on membrane-associated endpoints in cell culture preparations demonstrated changes in calcium efflux and in acetylcholinesterase activity following exposure to radiofrequency radiation, amplitude modulated (AM) at 16 and at 60 Hz, at a specific absorption rate of 0.05 W/kg. In this study, these modulation frequencies were tested for their influence on the activity of a cytoplasmic enzyme, enolase, which is being tested clinically for detection of neoplasia. Escherichia coli cultures containing a plasmid with a mammalian gene for enolase were exposed for 30 min, and cell extracts were assayed for enolase activity by measuring absorbance at 240 nm. The enolase activity in exposed cultures was compared to the activity in paired control cultures. Exposure to 147 MHz carrier waves at 0.05 W/kg, AM at 16 Hz showed enolase activity enhanced by 62%, and AM at 60 Hz showed enolase activity reduced by 28%. Similarly, exposure to 16 Hz fields alone, at 21.2 V/mrms (electric) and 97 nTrms (magnetic), showed enhancement in enolase activity by 59%, whereas exposure to 60 Hz fields alone, at 14.1 V/mrms (electric) and 65 nTrms (magnetic), showed reduction in activity by 24%. Sham exposures as well as exposure to continuous-wave 147 MHz radiation at 0.05 W/kg showed no change in enolase activity. Although the underlying basis for these field effects in the cytoplasmic compartment has not been established, differential sensitivities to 16 Hz and to 60 Hz signals provide a clear focus for additional research to determine the responsible mechanism. © 1994 Wiley-Liss, Inc.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 427-437 
    ISSN: 0197-8462
    Keywords: electric field exposure ; electromagnetic fields ; pineal function ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Sprague-Dawley male rats, maintained in a 14:10 h light:dark cycl were exposed for 30 days (starting at 56 days of age) to a 65 kV/m, 60 Hz electric field or to a sham field for 20 h/day beginning at dark onset. Pineal N-acetyltransferase (NAT), hydroxy-indole-o-methyl transferase (HIOMT), and melatonin as well as serum melatonin were assayed. Preliminary data on unexposed animals indicated that samples obtained 4 h into the dark period would reveal either a phase delay or depression in circadian melatonin synthesis and secretion. Exposure to electric fields for 30 days did not alter the expected nighttime increase in pineal NAT, HIOMT, or melatonin. Serum melatonin levels were also increased at night, but the electric field-exposed animals had lower levels than the sham-exposed animals. Concurrent exposure to red light and the electric field or exposure to the electric field at a different time of the day-night period did not reduce melatonin synthesis. These data do not support the hypothesis that chronic electric field exposure reduces pineal melatonin synthesis in young adult male rats. However, serum melatonin levels were reduced by electric field exposure, suggesting the possibility that degradation or tissue uptake of melatonin is stimulated by exposure to electric fields. © 1994 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    ISSN: 0197-8462
    Keywords: nonionizing fields ; teratogenic effects ; signal waveform ; pulsed magnetic fields ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Several reports have shown that weak, extremely-low-frequency (ELF), pulsed magnetic fields (PMFs) can adversely affect the early embryonic development of the chick. In this study, freshly fertilized chicken eggs were exposed during the first 48 h of postlaying incubation to PMFs with 100 Hz repetition rate, 1.0 μT peak-to-peak amplitude, and 500 μs pulse duration. Two different pulse waveforms were used, having rise and fall times of 85 μs (PMF-A) or 2.1 μs (PMF-B). It has been reported that, with 2 day exposure, these fields significantly increase the proportion of developmental abnormalities. In the present study, following exposure, the eggs were allowed to incubate for an additional 9 days in the absence of the PMFs. The embryos were taken out of the eggs and studied blind. Each of the two PMF-exposed groups showed an excess in the percentage of developmental anomalies compared with the respective sham-exposed samples. This excess of anomalies was not significant for the PMF-A-treated embryos (P = 0.173), whereas it was significant for the PMF-B-exposed group (P = 0.007), which showed a particularly high rate of early embryonic death. These results reveal that PMFs can induce irreversible developmental alterations and confirm that the pulse waveform can be a determinant factor in the embryonic response to ELF magnetic fields. The data also validate previous work based on the study of PMFs' effects at day 2 of embryonic development under field exposure. © 1994 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 399-409 
    ISSN: 0197-8462
    Keywords: noise ; coherence ; incoherence ; signal to noise ; ornithine decarboxylase ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: We have previously demonstrated that a weak, extremely-low-frequency magnetic field must be coherent for some minimum length of time (≍ 10 s) in order to affect the specific activity of ornithine decarboxylase (ODC) in L929 mouse cells. In this study we explore whether or not the superposition of an incoherent (noise) magnetic field can block the bioeffect of a coherent 60 Hz magnetic field, since the sum of the two fields is incoherent. An experimental test of this idea was conducted using as a biological marker the twofold enhancement of ODC activity found in L929 murine cells after exposure to a 60 Hz, 10 μTrms magnetic field. We superimposed an incoherent magnetic noise field, containing frequencies from 30 to 90 Hz, whose rms amplitude was comparable to that of the 60 Hz field. Under these conditions the ODC activity observed after exposure was equal to control levels. It is concluded that the superposition of incoherent magnetic fields can block the enhancement of ODC activity by a coherent magnetic field if the strength of the incoherent field is equal to or greater than that of the coherent field. When the superimposed, incoherent noise field was reduced in strength, the enhancement of ODC activity by the coherent field increased. Full ODC enhancement was obtained when the rms value of the applied EM noise was less than one-tenth that of the coherent field. These results are discussed in relation to the question of cellular detection of weak EM fields in the presence of endogenous thermal noise fields. © 1994 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994) 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 163-176 
    ISSN: 0197-8462
    Keywords: pulsed microwaves ; Rhesus monkey ; behavior ; high-peak-power ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Limits on the exposure to high-peak-power, short-duration microwave pulses have only recently been adopted. Additional data, however, are needed to understand the effects that may be produced by exposure to high-peak-power pulsed microwaves. Four male rhesus monkeys (Macaca mulatta) were trained on an operant task for food pellet reward to investigate the behavioral effects of very high-peak-power 5.62 GHz microwaves. The operant task required monkeys to pull one plastic lever on a variable interval schedule (VI-25 s) and then respond to color signals and pull a second lever to obtain food. The monkeys were conditioned to perform a color discrimination task using one of three colors displayed by a fiber-optic cable. A red signal was the discriminative stimulus for responding on the first lever. A response on the second lever when a green signal was presented (1 s duration) delivered a food pellet. If a response on the second lever was made in the presence of a white signal, a 30-s timeout occurred. While performing the behavioral task, the monkeys were exposed to microwave pulses produced by either a military radar (FPS-26A) operating at 5.62 GHz or the same radar coupled to a Stanford linear energy doubler (SLED) pulse-forming device (ITT-2972) that enhanced peak power by a factor of nine by adding a high power pulse to the radar pulse. The effects of both types of pulses were compared to sham exposure. Peak field power densities tested were 518, 1270, and 2520 W/cm2 for SLED pulses and 56, 128, and 277 W/cm2 for the radar pulses. The microwave pulses (radar or SLED) were delivered at 100 pps (2.8 μs radar pulse duration, ≈ 50 ns SLED pulse duration) for 20 min and produced averaged whole-body SARs of 2,4, or 6 W/kg. Compared to sham exposures, significant alterations of lever responding, reaction time, and earned food pellets occurred during microwave exposure at 4 and 6 W/kg but not 2 W/kg. There were no differences between radar or SLED pulses in producing behavioral effects. ©1994 Wiley-Liss, Inc.This is a US Government work and, as such, is in the public domain in the United States of America.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 177-181 
    ISSN: 0197-8462
    Keywords: CW microwaves ; mice ; longevity ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Female CD 1 mice were exposed from the thirty-fifth day of age for the remainder of their lives to 2.45 GHz, CW-microwave radiation at a power density of 3 or 10 m W/cm2 (SAR = 2.0 or 6.8 W/kg). Exposures took place 1 h/day, 5 day/week in an anechoic chamber at an ambient temperature of 22 °C and a relative humidity of 50%. There were 25 animals in each exposure group, and an equal number of controls were concurrently sham exposed. The average life span of animals exposed at 10 mW/cm2 was significantly shorter than that of sham-exposed controls (572 days vs. 706 days; P = .049; truncation 〉20%). In contrast, the average lifespan of the animals exposed at 3 mW/cm2 was slightly, but not significantly, longer (738 days) than that of controls (706 days). © 1994 Wiley-Liss, Inc.This article is a US Government work and, as such, is in the public domain in the United States of America.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 419-433 
    ISSN: 0197-8462
    Keywords: radiofrequency ; brain ; metabolism ; stripline ; fluorescence ; mechanism ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Three key compounds in brain energy metabolism have been measured during and after exposure to continuous wave radiofrequency radiation at 200, 591, and 2,450 MHz. Frequency-dependent changes have been found for all three compounds. Changes in NADH fluorescence have been measured on the surface of a surgically uncovered rat brain during exposure. At 200 and 591 MHz, NADH fluorescence increased in a dose-dependent manner between approximately 1 and 10 mW/cm2, then became constant at higher exposures. There was no effect at 2,450 MHz. Levels of ATP and CP were measured in whole brain after exposure. The ATP levels were decreased at 200 and 591 MHz but not at 2,450 MHz. The CP levels decreased only at 591 MHz. The effect of duration of exposure (up to 5 min) was investigated for all compounds at 200 MHz and 2,450 MHz, and exposures to 20 minutes were examined at 591 MHz. Temperature in the rat brain was essentially constant for all exposures. A general mechanism for inhibition of the mitochondrial electron transport chain and the CP-kinase reaction pathway by radiofrequency radiation has been proposed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 221-232 
    ISSN: 0197-8462
    Keywords: electromagnetic power absorption ; tissue-equivalent phantoms ; heating distributions ; specific absorption rate (SAR) ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The electromagnetic power absorption in tissue-equivalent phantoms that are used for evaluation of diathermy and hyperthermia applicators is analyzed for the purpose of determining the effect of an insulating partition that is frequently used to facilitate separation of the phantom for thermographic analysis of heating distributions. An analysis that is based on the plane wave spectrum decomposition of the electromagnetic field is applied to a simplified model of the medium. The simplified model is valid whenever the insulating partition does not significantly alter the fields in the medium. The curves that are presented indicate that thin partitions do not significantly alter the power absorption for most situations of therapeutic interest. Data on the effects of partition thickness and electrical parameters are presented for microwave and radiofrequencies of interest for diathermy and hyperthermia.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 247-261 
    ISSN: 0197-8462
    Keywords: 2.45-GHz radiation ; fluorescence polarization ; cytoplasm ; Chinese hamster cells ; microwaves ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: In order to demonstrate possible specific effects of microwaves at the cellular level V-79 Chinese hamster cells were exposed to 2.45-GHz radiation at power levels of 20-200 mW/cm2 and at specific absorption rates of 10-100 mW/g. Intracellular cytoplasmic changes were observed by fluorescence polarization using a method based on the intracellular enzymatic hydrolysis of nonfluorescent fluorescein diacetate (FDA). At levels of absorbed energy below 90 J/g, modifications of microviscosity and mitochondrial state were absent, but a slight stimulation of enzymatic hydrolysis of FDA was observed which may be explained by microwave-induced alterations of cellular membranes possibly due to differences in heating pattern of microwaves compared to water-bath heating. At levels of absorbed energy above 90 J/g, the decrease of enzymatic hydrolysis of FDA, increase in degree of polarization, and increase of permeation of the fluorescent marker correlated well with the decrease in cell viability as measured by the exclusion of trypan blue. At equal absorbed energy, microwaves were found to exert effects comparable to classical heating except that permeation was slightly more affected by microwave than by classical heating. This suggests that membrane alteration produced by microwaves might differ from those induced by classical heating or that microwaves may have heated the membrane to higher temperatures than did classical heating.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 283-291 
    ISSN: 0197-8462
    Keywords: microwaves ; Na transport ; oxygen tension ; erythrocytes ; membrane phase transitions ; protein shedding ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Microwave exposure (2450 MHz, 60 mW/g, CW) of rabbit erythrocytes increases Na passive transport only at membrane phase transition temperatures (Tc) of 17-19°C. This permeability effect is enhanced for relative hypoxia which is characteristic of intracellular oxygen tension (pO2 ≤ 5 mm Hg). Neither the permeability nor the pO2 effects are observed in temperature-matched (± 0.05°C), sham-exposed controls. In addition, at Tc, microwave exposure is observed to induce the shedding or release of two erythrocyte proteins not seen in sham-exposed controls. Moreover, the enhanced shedding of at least seven other proteins all of molecular weight ≤ 28,000 D was detected in the microwave-treated samples. Using sensitive silver staining we estimate that approximately 450 fg of protein were shed per erythrocyte. These results demonstrate that temperature and pO2 are important influences on both functional and structural responses of cell membranes to microwave radiation.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    ISSN: 0197-8462
    Keywords: power frequency fields ; ELF magnetic fields ; teratology ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Pregnant CD1 mice were exposed or sham-exposed from day 0 to day 17 of gestation to a 50 Hz sinusoidal magnetic field at 20 mT (rms). Preimplantation and postimplantation survival were assessed and fetuses examined for the presence of gross external, internal, and skeletal abnormalities. There were no statistically significant field-dependent effects on preimplantation or postimplantation survival, sex ratio, or the incidence of fetuses with internal or skeletal abnormalities. Magnetic field exposure was, however, associated with longer and heavier fetuses at term, with fewer external abnormalities. The results lend no support to suggestions of increased rates of spontaneous abortion or congenital malformation following prenatal exposure to power frequency magnetic fields. © 1994 Wiley-Liss, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994) 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 183-192 
    ISSN: 0197-8462
    Keywords: microwaves ; receptors ; protein shedding ; peroxidation ; lipids ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The effects of a continuous wave or pulse-modulated, 900 MHz microwave field were studied by in vitro assays of rat chemoreceptors. The pulsed field was modulated as rectangular waves at rates of 1, 6, 16, 32, 75, or 100 pps. The pulse-period to pulse-duration ratio was 5 in all cases, and specific absorption rates (SARs) ranged from 0.5 to 18 W/kg. Binding of ligands to cell membranes was differentially affected by exposure to microwaves. For example, binding of H3-glutamic acid to hippocampal cells was not altered by a 15 min exposure to a continuous wave field at 1 W/kg, but binding of H3-dihydroalprenolol to liver-cell membranes of neonates underwent a fivefold decrease under the same field conditions. This effect was not dependent on modulation or on a change in the constant of stimulus-receptor binding but depended on a shedding of the membrane's receptor elements into solution. The magnitude of inhibition correlated with the oxygen concentration in the exposed suspension. Antioxidants (dithiothreitol and ionol) inhibited the shedding of receptor elements. The microwave exposure did not cause an accumulation of products from the peroxidation of lipids (POL). Ascorbate-dependent or non-enzymatic POL was not responsible for the inhibition, and POL was not found in other model systems. However, enzymatic POL mechanisms in localized areas of receptor binding remain a possibility. © 1994 Wiley-Liss, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    ISSN: 0197-8462
    Keywords: exposure indices ; epidemiology ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Power-frequency electric and magnetic fields are known to exhibit marked temporal variation, yet in the absence of clear biological indications, the most appropriate summary indices for use in epidemiologic studies are unknown. In order to assess the statistical patterns among candidate indices, data on 4383 worker-days for magnetic fields and 2082 worker-days for electric fields collected for the Electric and Magnetic Field Project for Electric Utilities using the EMDEX meter [Bracken (1990): Palo Alto, CA: Electric Power Research Institute] were analyzed. We examined correlations at the individual and job title group levels among indices of exposure to both electric and magnetic fields, including the arithmetic mean, geometric mean, median, 20th and 90th percentiles, time above lower cutoffs of 20 V/m and 0.2 μT, and time above higher cutoffs of 100 V/m and 2.0 μT. For both electric and magnetic fields, the arithmetic mean was highly correlated with the 90th percentile; moderately correlated with the geometric mean, median, and lower and higher cutoff scores; and weakly correlated with the 20th percentile. Electric and magnetic field indices were generally weakly correlated with one another. Rank-order correlation coefficients were consistently greater than product-moment correlation coefficients. Job title group summary scores showed higher correlations among electric field indices and magnetic field indices and between electric and magnetic field indices than was found for individual worker-days, with only the 20th percentile clearly independent of the others. These results suggest that individuals' exposures are adequately characterized by a measure of central tendency for electric and magnetic fields, such as the arithmetic or geometric mean, and an indicator of a lower threshold or cutoff for each field type, such as the 20th percentile or proportion of time above 20 V/m or 0.2 μT. A single measure of central tendency for each type of field appears to be adequate when exposures are assessed at the job title level. © 1994 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...