    Publication Date: 2011-08-24
    Description: Commercially available hot wires/films were used to measure the velocities of evaporated hydrogen or helium gas during cryogenic mixing experiments. Hot wires were found to be too delicate to use in this harsh environment. Hot films were rugged enough to use at cryogenic temperatures even though they failed after a number of thermal cycles. Since the hot films have small aspect ratios, 13.4 and 20, they are quite sensitive to the thermal loading, Tw/Tg, even with a correction for the conduction end loss. In general, although the increase of the Nusselt number with Reynolds number at low temperatures was similar to that at room temperature, there was also a pronounced variation with Tw/Tg over the large range of 1.2 to 12 investigated.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: ASME, Transactions, Journal of Heat Transfer (ISSN 0022-1481); 114; 4; p. 859-865.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: In an effort to improve the signal to noise in an interference experiment, we have developed a method to remove systematic phase drift between data sets acquired over long time intervals. Using this technique, it is possible to average repeatedly acquired phase measurements and improve the phase estimate without sacrificing spatial resolution. Results from tests using real-time phase stepping holographic interferometry applied to cantilever bending of a piezoelectric bimorph indicate that white noise has been reduced from 3 to less than 1 deg (lambda/360) by averaging 36 phase compensated data sets before object bending and 36 data sets after bending.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Laser interferometry IV: Computer-aided interferometry; Proceedings of the Meeting, San Diego, CA, July 22-24, 1991 (A93-44185 18-35); p. 221-230.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-24
    Description: The solar corona, supernova remnants, the hot diffuse interstellar gas in the Galaxy, galactic halos, and the hot intracluster gas in rich clusters of galaxies, are examples of extended astrophysical plasmas which emit line-rich spectra in the X-ray spectral range from 1.5 to 25 A. These phenomena represent a significant fraction of the baryonic matter in the universe. The study of the composition, structure and dynamics of these astrophysical plasmas requires observations with both high spectral and spatial resolution simultaneously. The Objective Double Crystal Spectrometer, coupled with a grazing incidence X-ray telescope, represents a stigmatic instrument which is highly efficient for the study of such sources. We describe the configuration and performance (spatial resolution, spectral resolution and efficiency) of the Objective Double Crystal spectrometer.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Multilayer and grazing incidence X-ray(EUV optics; Proceedings of the Meeting, San Diego, CA, July 22-24, 1991 (A93-39658 15-74); p. 461-470.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-24
    Description: The present treatment of vector magnetic field measurement in coronas by means of the Hanle effect of the Lyman-alpha line uses data from all-reflecting imaging coronagraph/polarimeters. The polarization sensitivity, bandpass, and spatial resolution of these instruments are defined through a modeling of the Hanle-effect signature in Lyman-alpha emission from coronal magnetic loops; the line-of-sight integration through an inhomogeneous coronal medium is taken into account. The use of the Hanle effect to measure solar corona vector magnetic fields is verified.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Multilayer and grazing incidence X-ray(EUV optics; Proceedings of the Meeting, San Diego, CA, July 22-24, 1991 (A93-39658 15-74); p. 402-413.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-24
    Description: Multilayer optics operated at normal incidence offer a powerful new technology for the study of the solar spectrum in the XUV. The spectra of most cosmic X-ray sources are strongly extinguished at wavelengths above 40 A due to absorption and scattering by interstellar grains. We describe a number of configurations which allow multilayer optics to be used at nonnormal angles of incidence in conjunction with grazing incidence optics to analyze the spectra of cosmic X-ray sources in the wavelength interval between 1.5 and 40 A. These optical configurations utilize both multilayer mirrors and gratings, and permit the efficient observation of extended sources using stigmatic spectrographs. The response of the instruments described to typical cosmic X-ray sources is also discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Multilayer and grazing incidence X-ray(EUV optics; Proceedings of the Meeting, San Diego, CA, July 22-24, 1991 (A93-39658 15-74); p. 333-344.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-24
    Description: The rocketborne Multi-Spectral Solar Telescope Array (MSSTA) uses an array of Ritchey-Chretien, Cassegrain, and Herschelian telescopes to produce ultrahigh-resolution full-disk images of the sun within the soft X-ray, EUV, and FUV ranges. Such imaging of the solar disk and corona out to several solar radii placed great demands on the MSSTA's data storage capabilities; in addition, its photographic films required very low outgassing rates. Results are presented from calibration tests conducted on the MSSTA's emulsions, based on measurements at NIST's synchrotron facility.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Multilayer and grazing incidence X-ray(EUV optics; Proceedings of the Meeting, San Diego, CA, July 22-24, 1991 (A93-39658 15-74); p. 188-204.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-24
    Description: The spherical Schwarzschild microscope for soft X-ray applications in microscopy and projection lithography consists of two concentric spherical mirrors configured such that the third-order spherical aberration and coma are zero. Since multilayers are used on the mirror substrates for X-ray applications, it is desirable to have only two reflecting surfaces in a microscope. To reduce microscope aberrations and increase the field of view, generalized mirror surface profiles are here considered. Based on incoherent and sine wave modulation transfer function calculations, the object plane resolution of a microscope has been analyzed as a function of the object height and numerical aperture (NA) of the primary for several spherical Schwarzschild, conic, and aspherical Head reflecting two-mirror microscope configurations. The Head microscope with a NA of 0.4 achieves diffraction limited performance for objects with a diameter of 40 microns. Thus, it seems possible to record images with a feature size less than 100 A with a 40x microscope when using 40 A radiation.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Multilayer and grazing incidence X-ray(EUV optics; Proceedings of the Meeting, San Diego, CA, July 22-24, 1991 (A93-39658 15-74); p. 117-124.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2011-08-24
    Description: Consideration is given to a cryogenic multichannel electronically scanned pressure (ESP) module developed and tested over an extended temperature span from -184 to +50 C and a pressure range of 0 to 5 psig. The ESP module consists of 32 pressure sensor dice, four analog 8 differential-input multiplexers, and an amplifier circuit, all of which are packaged in a physical volume of 2 x 1 x 5/8 in with 32 pressure and two reference ports. Maximum nonrepeatability is measured at 0.21 percent of full-scale output. The ESP modules have performed consistently well over 15 times over the above temperature range and continue to work without any sign of degradation. These sensors are also immune to repeated thermal shock tests over a temperature change of 220 C/sec.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 38th, Las Vegas, NV, Apr. 26-30, 1992, Proceedings (A93-37851 15-35); p. 773-791.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2011-08-24
    Description: The paper reports the development and initial testing of a digital resolver to replace existing analog signal processing instrumentation. Radiometers, mounted directly on one of the fully articulated blades, are electrically connected through a slip ring to analog signal processing circuitry. The measured signals are periodic with azimuth angle and are resolved into harmonic components, with 0 deg over the tail. The periodic nature of the helicopter blade motion restricts the frequency content of each flapping and yaw signal to the fundamental and harmonics of the rotor rotational frequency. A minicomputer is employed to collect these data and then plot them graphically in real time. With this and other information generated by the instrumentation, a helicopter test pilot can then adjust the helicopter model's controls to achieve the desired aerodynamic test conditions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 38th, Las Vegas, NV, Apr. 26-30, 1992, Proceedings (A93-37851 15-35); p. 619-628.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2011-08-24
    Description: Multi-component strain-gage force transducer design requires the designer to determine the spring constant of the numerous beams or flexures incorporated in the transducer. The classical beam deflection formulae that are used in calculating these spring constants typically assume that the beam has a uniform moment of inertia along the entire beam length. In practice all beams have a radius at the end where the beam interfaces with the shoulder of the transducer, and on short beams in particular this increases the beam spring constant considerably. A Basic computer program utilizing numerical integration is presented to determine this effect.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 38th, Las Vegas, NV, Apr. 26-30, 1992, Proceedings (A93-37851 15-35); p. 417-432.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-24
    Description: The objective is to describe continuing efforts to develop methods for measuring surface heat flux, gauge active surface temperature, and heat transfer coefficient quantities. The methodology involves inventing a procedure for fabricating improved plug-type heat flux gauges and also for formulating inverse heat conduction models and calculation procedures. These models and procedures are required for making indirect measurements of these quantities from direct temperature measurements at gauge interior locations. Measurements of these quantities were made in a turbine blade thermal cycling tester (TBT) located at MSFC. The TBT partially simulates the turbopump turbine environment in the Space Shuttle Main Engine. After the TBT test, experiments were performed in an arc lamp to analyze gauge quality.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 38th, Las Vegas, NV, Apr. 26-30, 1992, Proceedings (A93-37851 15-35); p. 263-271.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Publication Date: 2011-08-24
    Description: A ground-based optical telescope system has been constructed with the capability to locate fast optical transients that may be associated with gamma-ray bursts (GRBs). The instrument has been integrated and operated during a shakedown period at GSFC, Maryland. Results of 35 hours of 'state mode' data are presented. The telescope has the proven capability to slew to any point on the night sky within 1.0 sec, track that position with better than one arcsecond stability, and image a 9 x 12 arcmin field of view with 1 arcsec angular resolution with 1.5 sec time resolution. The telescope-CCD camera system has a sensitivity of 13th magnitude for transients and 14th mag for field stars. In the 35 hr of operation many single frame transients of instrumental and optical origin have been observed; no two-sequential frame astrophysical transients have been identified. The combined rate of instrumental transients (predominantly sea-level muons) is 7.2/hr and of optical transients (satellite glints, airplane strobe lights, and meteors) is 5.1/hr. The RMT will operate in conjunction with the MIT Explosive Transient Camera survey instrument at Kitt Peak National Observatory, Tucson. The RMT is now being installed at Kitt Peak. Full operation will begin this summer.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Robotic telescopes in the 1990s; Proceedings of the Symposium, 103rd Annual Meeting of the Astronomical Society of the Pacific, Univ. of Wyoming, Laramie, June 22-24, 1991, 1991 (A93-36457 14-89); p. 137-150.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Publication Date: 2011-08-24
    Description: This paper describes a recently completed electrooptical camera flying onboard the NASA ER-2 high altitude aircraft. The device includes a six-position filter wheel which can be fitted with a combination of polarizing and/or spectral filters. An alternate configuration will include a polarizing filter which can be rotated to any angle under computer control. The camera mount in the nose of the ER-2 can tilt forward or aft up to 40 degrees, both for bidirectional reflectance studies and for image motion compensation (the aircraft moves 34 meters between frame acquisitions). The ground resolution is nominally 5 meters from and altitude of 20 km. Spectral responsivity is that of the silicon imaging array (Kodak KAF-1400). Initial data sets were acquired in support of the International Satellite Cloud Climatology Program Regional Experiment of November, 1991, and will be used to study cirrus cloud properties.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Polarization and remote sensing; Proceedings of the Meeting, San Diego, CA, July 22, 23, 1992 (A93-30026 11-35); p. 200-204.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-24
    Description: Microstrip detectors in which the usual discrete anode and cathode wires are replaced by conducting strips on an insulating or partially insulating substrate are fabricated using integrated circuit-type photolithographic techniques and hence offer very high spatial accuracy and uniformity, together with the capability of producing extremely fine electrode structures. Microstrip proportional counters have now been variously reported having an energy resolution of better than 11 percent FWHM at 5.9 keV. They have been fabricated with anode bars down to 2 microns and on a variety of substrate materials including thin films which can be molded to different shapes. This review will examine the development of the microstrip detector with emphasis on the qualities which make this detector particularly interesting for use in astronomy.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: EUV, X-ray, and gamma-ray instrumentation for astronomy III; Proceedings of the Meeting, San Diego, CA, July 22-24, 1992 (A93-29476 10-35); p. 96-103.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Publication Date: 2011-08-24
    Description: The description, analysis, and experimental results of a method for identifying possible defects on High Temperature Reusable Surface Insulation (HRSI) of the Orbiter Thermal Protection System (TPS) is presented. Currently, a visual postflight inspection of Orbiter TPS is conducted to detect and classify defects as part of the Orbiter maintenance flow. The objective of the method is to automate the detection of defects by identifying anomalies between preflight and postflight images of TPS components. The initial version is intended to detect and label gross (greater than 0.1 inches in the smallest dimension) anomalies on HRSI components for subsequent classification by a human inspector. The approach is a modified Golden Template technique where the preflight image of a tile serves as the template against which the postflight image of the tile is compared. Candidate anomalies are selected as a result of the comparison and processed to identify true anomalies. The processing methods are developed and discussed, and the results of testing on actual and simulated tile images are presented. Solutions to the problems of brightness and spatial normalization, timely execution, and minimization of false positives are also discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Cooperative intelligent robotics in space III; Proceedings of the Meeting, Boston, MA, Nov. 16-18, 1992 (A93-29101 10-54); p. 330-340.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Publication Date: 2011-08-24
    Description: The Capaciflector, a capacitive proximity sensor, is being developed by NASA for collision avoidance. Capaciflector provides a single output value as measure of altered base frequency. This value is a characteristic of an external object in the sensor's field of view. An attempt is made to use the Capaciflector for imaging with operating range from 1 to 2 inches. By positional arangement of sensors in a grid pattern and electronic activation of sensors over the grid one at a time an object characteristic image is obtained. The article describes the Capaciflector experimental imaging system and preliminary results obtained by the system.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Cooperative intelligent robotics in space III; Proceedings of the Meeting, Boston, MA, Nov. 16-18, 1992 (A93-29101 10-54); p. 13-24.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Publication Date: 2011-08-24
    Description: There will be a need for a wide array of chemical sensors for biomedical experimentation and for the monitoring of water and air recycling processes on Space Station Freedom. The infrequent logistics flights of the Space Shuttle will necessitate onboard analysis. The advantages of biosensors and chemical sensors over conventional analysis onboard spacecraft are manifold. They require less crew time, space, and power. Sample treatment is not needed. Real time or near-real time monitoring is possible, in some cases on a continuous basis. Sensor signals in digitized form can be transmitted to the ground. Types and requirements for chemical sensors to be used in biomedical experimentation and monitoring of water recycling during long-term space missions are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Biosensors and Bioelectronics (ISSN 0956-5663); 7; 8; p. 535-548.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Publication Date: 2011-08-24
    Description: A liquid crystal television (LCTV) SLM's phase, amplitude, and polarization all influence our selection of operating curves for input and filter. With its continuum of drive voltage, the LCTV permits grey-level control in both locations. Selection of an optimum curve depends on expected variations in signal amplitude, presence of input scene structured noise, and other factors. Using modulators obtained from a commercially available projection LCTV, and with no specifically added input noise present, we have obtained laboratory results in which the ratio of peak intensity to correlator system noise exceeded 100:1. Unfortunately, it was massively inefficient to implement the algorithm which had been developed as the abstract for this paper was submitted. Fortunately, we have quite recently developed two insights that will speed it by several orders of magnitude, and we shall report that result in the future. We will also extend the work to include clutter objects and additive input scene noise.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Optical pattern recognition III; Proceedings of the Meeting, Orlando, FL, Apr. 21, 22, 1992 (A93-28672 10-63); p. 78-82.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Publication Date: 2011-08-24
    Description: The features and the components of a new microscale guidance, navigation, and control (GN&C) system for future space systems are discussed. An approach is described for the utilization of new microengineering technologies for achieving major reductions in the GN&C system's mass, size, power, and costs. The micro-GN&C system and the component concepts include microactuated adaptive optics, micromachined inertial sensors, fiberoptic data nets with light-power transmission, and VLSI microcomputers. The GN&C system will be applied in microspacecraft, microlanders, microrovers, remote sensing platforms, interferometers, and deployable reflectors.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Sensors and sensor systems for guidance and navigation II; Proceedings of the Meeting, Orlando, FL, Apr. 22, 23, 1992 (A93-28151 10-35); p. 144-158.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Publication Date: 2011-08-24
    Description: NASA's Office of Commercial Programs is funding a multispectral sensor system to be used in the development of remote sensing applications. The Airborne Terrestrial Applications Sensor (ATLAS) is designed to provide versatility in acquiring spectral and spatial information and will be a test bed for the development of specifications for airborne and spaceborne remote sensing instrumentation for dedicated applications. This objective requires spectral coverage from the visible through thermal IR wavelengths, variable spatial resolution form 2-25 meters; high geometric and geolocation accuracy; on-board radiometric calibration; digital recording; and optimized performance for minimized cost, size, and weight.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Small satellite technologies and applications II; Proceedings of the Meeting, Orlando, FL, Apr. 21, 22, 1992 (A93-28076 10-12); p. 63-74.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-24
    Description: The Electronic Still Camera (ESC) project has been implemented in its first form for space shuttle operations. The system is composed of three components: (1) a hand-held battery-operated fully digital and programmable high-resolution camera; (2) a laptop-computer-based playback/downlink unit for onboard image processing; and (3) a ground station capable of receiving shuttle data, processing images, producing hardcopies, and distributing the data and hardcopies to end users. The advantages of the ESC system over film and satellites are discussed, and system specifications are summarized.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: IGARSS '92; Proceedings of the 12th Annual International Geoscience and Remote Sensing Symposium, Houston, TX, May 26-29, 1992. Vol. 1 (A93-47551 20-43); p. 149-151.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Publication Date: 2011-08-24
    Description: Permittivity may be determined by measuring the complex reflection coefficient of an open-ended coaxial line placed in contact with a test sample. This method works best for liquid samples. For the measurement of non-liquid materials problems can arise. A perfect preparation is needed to provide a good contact between the tip and the dielectric medium. At times, the dimension of the sensor cannot be freely chosen, as is the case for the measurement of the dielectric constant of the xylem layer of a living tree. The influence of the installation of the sensor on a tree's water status must be minimized by using a small sensor. In such cases the capacitance cannot be optimized. By extending the center conductor of the open-ended coaxial line, some of these problems can be avoided. This provides an additional tool to tune the capacitance of the sensor by adjusting the length of the extension. Therefore the measurement accuracy can be optimized. The sensor also becomes sensitive to a larger volume. A comparative study of a flush and extended tipped probes shows that the ability to measure the dielectric constant of trees has been notably increased due to the extension of the center conductor.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: IGARSS '92; Proceedings of the 12th Annual International Geoscience and Remote Sensing Symposium, Houston, TX, May 26-29, 1992. Vol. 1 (A93-47551 20-43); p. 443-445.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Publication Date: 2011-08-24
    Description: An analysis is presented that establishes how correction-free radiance measurements or pyrometry can be performed on targets in furnaces where there may be significant additional radiance from heated furnace walls or from reflecting surfaces close to the target. These configurations are common in microgravity and containerless processing applications where a specular target is radiantly heated in a hot-wall furnace, or inductively heated from the fields arising from nearby closely spaced electromagnetic coils. Proper design requires that the pyrometer does not view any images of the background features in the specular target so that stray radiation will not be reflected into the viewing optics of the pyrometer. To analyze the problem, conventional paraxial optics analysis is shown to be significantly in error. Instead a method of nonparaxial ray tracing, based on the derivatives of the ray paths, shows how the images must be located. This leads to analytical results that can be used to design such systems. The findings are applied to the furnace geometries that are presently being considered for flight in LEO.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments (ISSN 0034-6748); 63; 11; p. 5394-5402.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Publication Date: 2011-08-24
    Description: A technique is described which combines up to three channels of imagery into a single 8-bit composite color image. Each image controls a specific color or colors (red, green, or blue) in the resultant color composite image, allowing for improved interpretation of scene characteristics. The technique is a useful tool for the forecaster and satellite image analyst. In addition to providing the capability of displaying multichannel images on an 8-bit desktop color workstation, the technique allows sophisticated image manipulation to be performed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Conference on Satellite Meteorology and Oceanography, 6th, Atlanta, GA, Jan. 5-10, 1992, Preprints (A93-36051 14-47); p. J92-J95.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Publication Date: 2011-08-24
    Description: We present Monte Carlo analysis and experimental data from a novel lithium-drifted silicon detector stack for gamma ray spectroscopy instrumentation in future Mars surface landers and other planetary missions. The Monte Carlo analysis shows full energy photopeaks even in the range of about 100 keV to 2 MeV where, in Si, Compton scattering dominates the absorption processes. Laboratory data is shown for an experimental detector stack of four planar Si(Li) devices, each 5 mm thick with an active area 2 cm in diameter. All the experimental data were collected with maximum temperature of the stack at 175 K. Background reduction is achieved by using the detector of the stack closest to the source in anticoincidence. We present a comparison of experimental data from the stack with the Monte Carlo model for Cs-137 (662 keV). Agreement is shown to be good, with a full energy photopeak clearly seen (FWHM about 10 keV). Experimental stack data is also shown for multiple peaks at 511 keV (Na-22) and 662 keV (Cs-137). The peaks are clearly resolved (FWHM 10 keV), and are compared with the results obtained using a 8 percent resolution, 3 in. x 3 in. NaI(TI) device (FWHM about 50 keV).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Nuclear Science (ISSN 0018-9499); 39; 4; p. 981-986.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Publication Date: 2011-08-24
    Description: An Automated Thermocouple Calibration System (ATCS) was developed for the unattended calibration of type K thermocouples. This system operates from room temperature to 650 C and has been used for calibration of thermocouples in an eight-zone furnace system which may employ as many as 60 thermocouples simultaneously. It is highly efficient, allowing for the calibration of large numbers of thermocouples in significantly less time than required for manual calibrations. The system consists of a personal computer, a data acquisition/control unit, and a laboratory calibration furnace. The calibration furnace is a microprocessor-controlled multipurpose temperature calibrator with an accuracy of +/- 0.7 C. The accuracy of the calibration furnace is traceable to the National Institute of Standards and Technology (NIST). The computer software is menu-based to give the user flexibility and ease of use. The user needs no programming experience to operate the systems. This system was specifically developed for use in the Microgravity Materials Science Laboratory (MMSL) at the NASA LeRC.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Instrumentation and Measurement (ISSN 0018-9456); 41; 5; p. 702-706.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-24
    Description: A novel optical proximity sensor system, capable of measuring the distance to the orientation and the discontinuity at a local area of an object surface, was designed and evaluated for robotic applications. The sensor system gets its name, Hexagonal Eye, (HexEYE) from its shape where seven identical hexagonal sensing units were configured hexagonally into a compact geometric structure. The seven sensing units were grouped into multiple combinations of three sensing units to measure the surface orientation as well as surface discontinuity. The distinctive features of HexEYE are an order of magnitude increased in distance sensitivity by optimizing the curvature of a conical mirror, the enhanced measurement accuracy based on multiple levels of sensor fusion, and the compactness in size due to a sensing mechanism based on the Gaussian lens law. A prototype of single sensing unit has been built and was evaluated experimentally.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: 1992 IEEE International Conference on Robotics and Automation, 8th, Nice, France, May 12-14, 1992, Proceedings. Vol. 2 (A93-35501 13-63); p. 1567-1572.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Publication Date: 2011-08-24
    Description: The Airborne Ocean Color Imager was developed as an aircraft instrument to simulate the spectral and radiometric characteristics of the next generation of satellite ocean color instrumentation. Data processing programs have been developed as extensions of the Coastal Zone Color Scanner algorithms for atmospheric correction and bio-optical output products. The latter include several bio-optical algorithms for estimating phytoplankton pigment concentration, as well as one for the diffuse attenuation coefficient of the water. Additional programs have been developed to geolocate these products and remap them into a georeferenced data base, using data from the aircraft's inertial navigation system. Examples illustrate the sequential data products generated by the processing system, using data from flightlines near the mouth of the Mississippi River: from raw data to atmospherically corrected data, to bio-optical data, to geolocated data, and, finally, to georeferenced data.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Imaging Science and Technology (ISSN 8750-9237); 36; 5; p. 423-430.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Publication Date: 2011-08-24
    Description: Two-mode, elliptical-core optical fibers are demonstrated in weighted, distributed and selective vibration-mode-filtering applications. We show how appropriate placement of optical fibers on a vibrating structure can lead to vibration mode filtering. Selective vibration-mode suppression on the order of 10 dB has been obtained using tapered two-mode, circular-core fibers with tapering functions that match the second derivatives of the modes of vibration to be enhanced. We also demonstrate the use of chirped, two-mode gratings in fibers as spatial modal sensors that are equivalents of shaped piezoelectric sensors.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Distributed and multiplexed fiber optic sensors; Proceedings of the Meeting, Boston, MA, Sept. 4, 5, 1991 (A93-49426 21-35); p. 53-66.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Publication Date: 2011-08-24
    Description: New methods have been developed to implement high-resolution position sensors based on electron tunneling. These methods allow miniaturization while utilizing the position sensitivity of electron tunneling to give high resolution. A single-element tunneling accelerometer giving a displacement resolution of 0.002 A/sq rt Hz at 10 Hz, corresponding to an acceleration resolution of 5 x 10 exp -8 g/sq rt Hz, is described. A new dual-element tunneling structure which overcomes the narrow bandwidth limitations of a single-element structure is described. A sensor with an operating range of 5 Hz to 10 kHz, which can have applications as an acoustic sensor, is discussed. Noise is analyzed for fundamental thermal vibration of the suspended masses and is compared to electronic noise. It is shown that miniature tunnel accelerometers can achieve resolution such that thermal noise in the suspended masses is the dominant cause of the resolution limit. With a proof mass of order 100 mg, noise analysis predicts limiting resolutions approaching 10 exp -9 g/sq rt Hz in a 300 Hz band and 10 exp -8 g/sq rt Hz at 1 kHz.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: ; : International Conf
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Publication Date: 2011-08-24
    Description: A three-dimensional theoretical model based on the application of the thermal conduction and Navier equations to a chopped electron beam incident on a disk specimen is used to obtain the particle displacement field in the specimen. The results lead to a consideration of the signal generation, spatial resolution, and contrast mechanisms in scanning electron acoustic microscopy (SEAM). The model suggests that the time-variant heat source produced by the beam chopping generates driving source, thermal wave, and acoustic wave displacements simultaneously in the specimen. Evidence of the correctness of the prediction is obtained from the mathematically similar problem of pulsed laser light injection into a tank of water. High speed Schlieren photographs taken following laser injection show the simultaneous evolution of thermal and acoustic waveforms. Examples of contrast reversal, stress-induced contrast, and acoustic zone contrast and resolution with SEAM are presented and explained in terms of the model features.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: ; : Conference on the
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Publication Date: 2011-08-24
    Description: This manuscript outlines a continuing effort to validate and verify the performance of an airborne autonomous wavemeter for tuning solid state lasers to a desired wavelength. The application is measuring the vertical profiles of atmospheric water vapor using a differential absorption lidar (DIAL) technique. Improved wavemeter performance data for varying ambient temperatures are presented. This resulted when the electronic grounding and shielding were improved. The results with short pulse duration lasers are also included. These lasers show that similar performance could be obtained with lasers operating in the continuous and the pulsed domains.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Laser interferometry IV: Computer-aided interferometry; Proceedings of the Meeting, San Diego, CA, July 22-24, 1991 (A93-44185 18-35); p. 110-116.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Publication Date: 2011-08-24
    Description: The non-pressure response of a PCB Model 113A transducer to a far infrared radiation impulse from a carbon dioxide laser was investigated. Incident radiation was applied both to the bare transducer diaphragm and to coated diaphragms. Coatings included two common ablative materials and a reflective gold coating. High-flux radiation impulses induced an immediate brief negative output followed by a longer-duration positive output. Both timing and amplitude of the responses will be discussed, and the effects of coatings will be compared. Bursts of blackbody radiation from a 1500 K source produced qualitatively similar responses.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 38th, Las Vegas, NV, Apr. 26-30, 1992, Proceedings (A93-37851 15-35); p. 793-807.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Publication Date: 2011-08-24
    Description: This paper outlines the design and development of a flameout detection system for future use in the 8-Foot High Temperature Wind Tunnel (8' HTT) at the NASA Langley Research Center. The proposed system is required to function reliably in an oxidizing environment with pressures up to 28 MPa (4,000 psi), survive temperatures reaching 1700 C (3100 F), and respond with a shut-down signal upon flameout in less than 100 milliseconds. The 7-Inch High Temperature Pilot Tunnel (7" HTT), a one-twelfth scale version of the 8' HTT, was used to develop a prototype system and to obtain data on the spectral content of the flame during combustion. The design and development of the spectral data acquisition system for the 7" HTT is presented here.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 38th, Las Vegas, NV, Apr. 26-30, 1992, Proceedings (A93-37851 15-35); p. 629-638.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Publication Date: 2011-08-24
    Description: Tests were performed using commercially available silicon diode temperature sensors to detect the location of the liquid-vapor interface in hydrogen during ground test programs. Results show that by increasing the current into the sensor, silicon diodes can be used as liquid level point sensors. After cycling the sensors from liquid to vapor several times, it was found that with a 30 mA (milliamps) input current, the sensors respond within 2 seconds by measuring a large voltage difference when transitioning from liquid to vapor across the interface. Nearly instantaneous response resulted during a transition from vapor to liquid. Detailed here are test procedures, experimental results, and guidelines for applying this information to other test facilities.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 38th, Las Vegas, NV, Apr. 26-30, 1992, Proceedings (A93-37851 15-35); p. 287-299.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-24
    Description: To provide an uncomplicated and inexpensive method for measuring the far-field velocity of a surface shockwave produced by an explosion, a stepwise shockwave velocity determinator (SSVD) was developed. The velocity determinator is constructed of readily available materials and works on the principle of breaking discrete sensors composed of aluminum foil contacts. The discrete sensors have an average breaking threshold of approximately 7 kPa. An incremental output step of 250 mV is created with each foil contact breakage and is logged by analog-to-digital instrumentation. Velocity data obtained from the SSVD is within approximately 11 percent of the calculated surface shockwave velocity of a muzzle blast from a 30.06 rifle.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 38th, Las Vegas, NV, Apr. 26-30, 1992, Proceedings (A93-37851 15-35); p. 157-163.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Publication Date: 2011-08-24
    Description: A cryogenic blackbody radiation source for providing target temperatures between room temperature and -100 C was designed, fabricated, and tested. This blackbody radiation source is intended for calibration of radiometric infrared imaging systems down to -100 C. The construction and operating principles of this apparatus are described. The long term and short term stability of the radiant source have been investigated. The emittance of the source and the source radiant uniformity have been addressed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 38th, Las Vegas, NV, Apr. 26-30, 1992, Proceedings (A93-37851 15-35); p. 273-285.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Publication Date: 2011-08-24
    Description: The analysis and prototype results of a dual-amplifier circuit for measuring blade-tip clearance in turbine engines are presented. The capacitance between the blade tip and mounted capacitance electrode within a guard ring of a probe forms one of the feedback elements of an operational amplifier (op amp). The differential equation governing the circuit taking into consideration the nonideal features of the op amp was formulated and solved for two types of inputs (ramp and dc) that are of interest for the application. Under certain time-dependent constraints, it is shown that (1) with a ramp input the circuit has an output voltage proportional to the static tip clearance capacitance, and (2) with a dc input, the output is proportional to the derivative of the clearance capacitance, and subsequent integration recovers the dynamic capacitance. The technique accommodates long cable lengths and environmentally induced changes in cable and probe parameters. System implementation for both static and dynamic measurements having the same high sensitivity is also presented.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Instrumentation and Measurement (ISSN 0018-9456); 41; 5; p. 674-678.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Publication Date: 2011-08-24
    Description: A NICMOS II array, a NIR (0.80 - 2.6 micron) imaging system, was integrated into the California Institute of Technology Palomar Observatory camera. The Palomar camera system which consists of six discrete subsystems including a focal plane, an electrical interface, data acquisition electronics, a dewar, dewar optics, and the software is described. The performance and calibration data for each subsystem are presented. Emphasis is placed on test data on the focal plane performance.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Infrared technology XVIII; Proceedings of the Meeting, San Diego, CA, July 19-22, 1992 (A93-32826 12-35); p. 444-460.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Publication Date: 2011-08-24
    Description: This paper describes to relationship of polarimetric observations from orbital and aerial platforms and the determination optimum sun-target-sensor geometry. Polarimetric observations were evaluated for feature discrimination. The Space Shuttle experiment was performed using two boresighted Hasselblad 70 mm cameras with identical settings with linear polarizing filters aligned orthogonally about the optic axis. The aerial experiment was performed using a single 35 mm Nikon FE2 and rotating the linear polarizing filter 90 deg to acquire both minimum and maximum photographs. Characteristic curves were created by covertype and waveband for both aerial and Space Shuttle imagery. Though significant differences existed between the two datasets, the observed polarimetric signatures were unique and separable.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Polarization and remote sensing; Proceedings of the Meeting, San Diego, CA, July 22, 23, 1992 (A93-30026 11-35); p. 121-127.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Publication Date: 2011-08-24
    Description: Microstrip detectors are an exciting new development in proportional counter design fabricated using integrated circuit-type photolithography techniques; they therefore offer very high spatial accuracy and uniformity. A development program is underway at NASA-Marshall to produce large-area microstrips for use in an X-ray detector balloon flight program and to investigate the general performance limits of these new devices. Microstrips tested so far have been fabricated both in-house using standard photolithographic techniques and by an outside contractor using electron beam technology. Various substrate materials have been tested along with different electrode configurations. The distributions of pickup on subdivided cathodes on both top and bottom surfaces of the microstrips are also being investigated for use as two-dimensional imaging detectors. Data from these tests in the development of a large-area device will be presented.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: EUV, X-ray, and gamma-ray instrumentation for astronomy III; Proceedings of the Meeting, San Diego, CA, July 22-24, 1992 (A93-29476 10-35); p. 125-132.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Publication Date: 2011-08-24
    Description: For most imaging sensors, a constant (dc) pointing error is unimportant (unless large), but time-dependent (ac) errors degrade performance by either distorting or smearing the image. When properly quantified, the separation of the root-mean-square effects of random line-of-sight motions into dc and ac components can be used to obtain the minimum necessary line-of-sight stability specifications. The relation between stability requirements and sensor resolution is discussed, with a view to improving communication between the data analyst and the control systems engineer.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of the Astronautical Sciences (ISSN 0021-9142); 40; 4; p. 557-576.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Publication Date: 2011-08-24
    Description: The paper presents a three-dimensional mathematical model of signal generation and contrast in brittle materials and uses the model to simulate the effect of residual stress fields on the scanning electron acoustic microscopy (SEAM)-generated electron acoustic signal. According to the model, a positive (tensile) strain produces an increase in the output signal, whereas a negative (compressive) strain produces a decrease in the ouput signal. Dark field contrast conditions occur at a chopping frequency at which V2 - V1 is greater than 0 (where V2 = V is the SEAM output in a region of residual stresses, and V1 is the output in a stress-free region of the sample). Under ideal conditions (maximum contrast) V1 approaches zero. It was found that tensile strains of the order 0.2-0.3 percent, possible in brittle materials, would produce a variation of the acoustic output signal of the order 10 nV (about 1 percent), well within the image contrast and signal processing capability of the SEAM electronics.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: ; : Micro(
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Publication Date: 2011-08-24
    Description: The backstreaming contamination in the Space Power Facility, Ohio, was measured using small size clean silicon wafers as contamination sensors placed at all measurement sites. Two ellipsometric models were developed to measure the oil film with the contamination film refractive index of DC 705: a continuous, homogeneous film and islands of oil with the islands varying in coverage fraction and height. The island model improved the ellipsometric analysis quality parameter by up to two orders of magnitude. The continuous film model overestimated the oil volume by about 50 percent.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Vacuum Science and Technology A (ISSN 0734-2101); 10; 4; p. 2099-2104.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-24
    Description: The instrumental crosstalk associated with the Marshall Space Flight Center Vector Magnetograph and the solar crosstalk created by the magnetic field are described and their impact on the reconstruction of the solar vector magnetic field is analyzed. It is pointed out that identifying and correcting the crosstalk is important in the development of realistic models describing the solar atmosphere. Solar crosstalk is spatially dependent on the structure of the magnetic field while instrumental crosstalk is dependent on the position of the analyzer.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Polarization analysis and measurement; Proceedings of the Meeting, San Diego, CA, July 19-21, 1992 (A93-33401 12-35); p. 281-294.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Publication Date: 2011-08-24
    Description: The performance of a 640 x 480 PtSi, 3,5 microns (MWIR), Stirling cooled camera system with a minimum resolvable temperature of 0.03 is considered. A preliminary specification of a full-TV resolution PtSi radiometer was developed using the measured performance characteristics of the Stirling cooled camera. The radiometer is capable of imaging rapid thermal transients from 25 to 250 C with better than 1 percent temperature resolution. This performance is achieved using the electronic exposure control capability of the MOS focal plane array (FPA). A liquid nitrogen cooled camera with an eight-position filter wheel has been developed using the 640 x 480 PtSi FPA. Low thermal mass packaging for the FPA was developed for Joule-Thomson applications.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Infrared technology XVIII; Proceedings of the Meeting, San Diego, CA, July 19-22, 1992 (A93-32826 12-35); p. 386-400.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Publication Date: 2011-08-24
    Description: The light emitted by electron avalanches in a parallel plate chamber can be used to image the tracks of photoelectrons liberated by the interaction of an incident X-ray with the gas filling the chamber. The different morphologies of photoelectron tracks and minimum ionizing tracks can be used for charged particle rejection. The initial direction (before scattering) of the liberated photoelectron also contains information about the polarization of the incident radiation. We have built a small test chamber with which we have imaged photoelectron tracks using an intensified CCD camera. Our results show that optical imaging could be used in a hard X-ray imaging polarimeter useful for astronomy.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: EUV, X-ray, and gamma-ray instrumentation for astronomy III; Proceedings of the Meeting, San Diego, CA, July 22-24, 1992 (A93-29476 10-35); p. 252-261.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Publication Date: 2011-08-24
    Description: Results from the first flight of our proportional counter in an imaging telescope led us to rebuild the detector. We have used a Penning gas mixture (xenon + 1 percent isobutylene) and introduced a preamplification region to improve the energy resolution. We have rebuilt the pressure vessel making novel use of molybdenum as the housing material in order to reduce the residual instrument background, particularly in the fluorescence-gated mode for which the detector design has been optimized. We have also increased the sensitive gas depth from 9 to 14 cm to further increase the sensitivity to both fluorescent pairs and conventional singles. Our calibrations have shown that the overall energy resolution of the detector has been enhanced by a factor of 2, and we predict that the sensitivity at float will increase by a factor of 3 in the 50-70 keV energy band.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: EUV, X-ray, and gamma-ray instrumentation for astronomy III; Proceedings of the Meeting, San Diego, CA, July 22-24, 1992 (A93-29476 10-35); p. 236-244.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Publication Date: 2011-08-24
    Description: This paper presents an overview of the primary nonintrusive diagnostic techniques being developed by the NASA Langley Research Center to address the validation needs of Computational Fluid Dynamic (CFD) codes. The techniques include absorption in the UV and IR, Laser Induced Fluorescence, electron beam fluorescence, and a number of scattering techniques including Rayleigh, spontaneous Raman, and several coherent Raman spectroscopies. Most of the techniques are highly specialized, require complex data interpretation, and can satisfy only a few of the CFD needs. For these reasons, the evolving trend in flowfield diagnostics appears to favor a mode in which the diagnostic researcher, the experimental aerodynamicist, and the CFD community jointly define experiments based on the aeronautical requirements and on available diagnostic techniques.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: ICAS, Congress, 18th, Beijing, China, Sept. 20-25, 1992, Proceedings. Vol. 1 (A93-14151 03-01); p. 722-727.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Publication Date: 2011-08-24
    Description: This paper presents an intelligent adaptive control system for the control of a solid-liquid interface of a crystal while it is growing via directional solidification inside a multizone transparent furnace. The task of the process controller is to establish a user-specified axial temperature profile and to maintain a desirable interface shape. Both single-input-single-output and multi-input-multi-output adaptive pole placement algorithms have been used to control the temperature. Also described is an intelligent measurement system to assess the shape of the crystal while it is growing. A color video imaging system observes the crystal in real time and determines the position and the shape of the interface. This information is used to evaluate the crystal growth rate, and to analyze the effects of translational velocity and temperature profiles on the shape of the interface. Creation of this knowledge base is the first step to incorporate image processing into furnace control.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Crystal Growth (ISSN 0022-0248); 119; 3-4,
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-24
    Description: A new skin friction balance with moving belt has been developed for measurement of the surface shear stress component in the direction of belt motion. The device is described in this paper with typical measurement results. This instrument is symmetric in design with small moving mass negligible internal friction. It is 3.8 cm high, 3.8 cm long and 2.1 cm wide, with the sensing surface 0.7 cm wide and 1.5 cm long, and it can be made in various sizes. The unique design of this instrument has reduced some of the errors associated with conventional floating-element balances. The instrument can use various sensing systems and the output signal is a linear function of the wall shear stress. Measurements show good agreement with data obtained by the floating element balances and flat plate prediction techniques. Dynamic measurements have been made in a limited range. The overall uncertainty of measurement is estimated to be +/- 2 percent.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Experiments in Fluids (ISSN 0723-4864); 12; 6, Ap; 401-406
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Publication Date: 2011-08-24
    Description: A tissue-equivalent proportional counter spectrometer capable of measuring the absorbed dose and dose distribution as a function of LET and time, for all penetrating radiation in space, is described. This instrument weighs about 0.7 kg and was flown on the STS-31 (28.5 deg x 620 km) flight of the Space Shuttle, 24-29 April 1990. The measured total dose is in excellent agreement with the calculations based on the AP8MAX model of the trapped radiation belt protons. The observed LET frequency distribution is also in excellent agreement with calculations based on this model. Active instruments can provide more detailed dosimetry for crew risk assessment than the thermoluminescent detectors or a plastic track detector system.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Journal of Radiation Applications and Instrumentation, Part D: Nuclear Tracks and Radiation Measurements (ISSN 0735-245X); 20; 1, Ja
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Publication Date: 2011-08-24
    Description: Rayleigh-Brillouin spectra for heated nitrogen gas were measured by imaging the output of a Fabry-Perot interferometer onto a CCD array. The spectra were compared with the theoretical 6-moment model of Rayleigh-Brillouin scattering convolved with the Fabry-Perot instrument function. Estimates of the temperature and a dimensionless parameter proportional to the number density of the gas as functions of position in the laser beam were calculated by least-squares deviation fits between theory and experiment.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 31; 15, M
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Publication Date: 2011-08-24
    Description: A concept is presented for a high-resolution EUV/soft-X-ray imager that has much in common with the medical imaging procedure of tomography. The resulting instrument is compatible with a simpler, less costly spin-axis-stabilized spacecraft. To demonstrate the fidelity of the reconstruction procedure, the observation and reconstruction is simulated to compare the results with the original image.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Astrophysical Journal, Part 2 - Letters (ISSN 0004-637X); 389; L91-L93
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Publication Date: 2011-08-24
    Description: The analytical treatment of power efficiency (P(eff) is undertaken for the case of a positively guiding optical fiber with a thin-film source distributed in the core-cladding interface. The approach adopts the exact solution of the cylindrical optical fiber with an infinite cladding to account for differences between the indices of refraction of the core and the cladding. The excitation of low-loss leaky modes by the cladding is ignored, and only the injection by the evanescent field is considered. The formulas permit the analysis of the power-injection efficiency of fibers with arbitrary differences in indices of refraction. P(eff) does not always increase with V number, but rather varies slightly with wavelength and fiber-core radius and varies significantly with the difference in the indices of refraction. The theoretical results of the work are of interest for designing an atomic-O chemical sensor based on evanescent-wave coupling.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optical Engineering (ISSN 0091-3286); 31; 237-244
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Publication Date: 2011-08-24
    Description: A series of tensile tests were conducted on SiC/RBSN composites using different methods of strain measurement. The tests were used to find the optimum strain sensing device for use with continuous fiber reinforced ceramic matrix composites in ambient and high temperature environments. Bonded resistance strain gages were found to offer excellent performance for room temperature tests. The clip-on gage offers the same performance but significantly less time is required for mounting it to the specimen. Low contact force extensometers track the strain with acceptable results at high specimen temperatures. Silicon carbide rods with knife edges are preferred. The edges must be kept sharp. The strain measuring devices should be mounted on the flat side of the specimen. This is in contrast to mounting on the rough thickness side.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Testing and Evaluation (ISSN 0090-3973); 20; 4, Ju
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Publication Date: 2011-08-24
    Description: A noncontacting technique using scanning laser acoustic microscopy for making in situ tensile strain measurements of small diameter fibers was implemented for the tensile strain analysis of individual Nicalon SiC fibers (nominal diameter 15 microns). Stress vs strain curves for the fibers were plotted from the experimental data. The mean elastic modulus of the fibers was determined to be 185.3 GPa. Similar measurements were made for Carborundum SiC fibers (nominal diameter 28 microns) and Saphikon sapphire fibers (nominal diameter 140 microns).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Ceramic Engineering and Science Proceedings (ISSN 0196-6219); 13; 7-8,
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Publication Date: 2011-08-24
    Description: A new image processing based color capturing technique for the quantitative interpretation of liquid crystal images used in convective heat transfer studies is presented. This method is highly applicable to the surfaces exposed to convective heating in gas turbine engines. It is shown that, in the single-crystal mode, many of the colors appearing on the heat transfer surface correlate strongly with the local temperature. A very accurate quantitative approach using an experimentally determined linear hue vs temperature relation is found to be possible. The new hue-capturing process is discussed in terms of the strength of the light source illuminating the heat transfer surface, the effect of the orientation of the illuminating source with respect to the surface, crystal layer uniformity, and the repeatability of the process. The present method is more advantageous than the multiple filter method because of its ability to generate many isotherms simultaneously from a single-crystal image at a high resolution in a very time-efficient manner.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: ASME, Transactions, Journal of Turbomachinery (ISSN 0889-504X); 114; 4; p. 765-775.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Publication Date: 2011-08-24
    Description: A nighttime operating Raman lidar system that is designed for the measurement of high vertical and temporal resolution profiles of the water vapor mixing ratio and the aerosol backscattering ratio is described. The theory of the measurements is presented. Particular attention is given to operational problems that have been solved during the development of the system. Data are presented from Sept. 1987 and described in their meteorological context.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 31; 16, J
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Publication Date: 2011-08-24
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Aircraft (ISSN 0021-8669); 29; 289-293
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Publication Date: 2011-08-24
    Description: This paper reports on the development of a photoelastic fiber optic strain gage sensitive to transverse strain. The sensing element is made from an epoxy resin which is stress frozen to passively achieve the quadrature condition. Light, emitted from an LED operating at 820 nm, is transmitted to and from the sensing element via multimode fibers and the signal is detected using a dual channel operational photodiode/amplifier. This unique combination of optics and electronics produces a fiber optic sensor having a high signal to noise ratio which is lead-in/out insensitive. Results show that strains on the order of 1 microstrain can be measured over an 800 microstrain range and that dummy gages can be used for temperature compensation.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Congress on Experimental Mechanics, 7th, Las Vegas, NV, June 8-11, 1992, Proceedings. Vol. 2 (A94-12901 02-39); p. 1311-1318.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Publication Date: 2011-08-24
    Description: The development of a long-wave infrared optical simulator facilitates evaluation of the end-to-end performance of long wavelength infrared (LWIR) focal plane arrays (FPAs) in a system-like environment. This simulator provides selectable structured scene inputs to a focal plane module or array. Background irradiances as low as 10 exp 10 photons/sq cm s are achievable when the simulator is cooled with liquid helium. The optical simulator can generate single or multiple targets of controllable intensities, and uniform or structured background irradiances. The infrared scenes can be viewed in a stationary mode or dynamically scanned across the focal plane.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Test and evaluation of IR detectors and arrays II; Proceedings of the Meeting, Orlando, FL, Apr. 22, 23, 1992 (A94-12744 02-35); p. 176-187.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Publication Date: 2011-08-24
    Description: A simple measurement technique for measuring the variation of directional emittance of surfaces at various temperatures using commercially available radiometric IR imaging systems was developed and tested. This technique provided the integrated value of directional emittance over the spectral bandwidth of the IR imaging system. The directional emittance of flat black lacquer and red stycast, an epoxy resin, measured using this technique were in good agreement with the predictions of the electromagnetic theory. The data were also in good agreement with directional emittance data inferred from directional reflectance measurements made on a spectrophotometer.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Thermosense XIV; Proceedings of the International Conference on Thermal Sensing and Imaging Diagnostic Applications, Orlando, FL, Apr. 22-24, 1992 (A94-12410 02-35); p. 325-335.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Publication Date: 2011-08-24
    Description: A full-spectrum (encompassing radiation on both sides of the Wien displacement peak) multiwavelength pyrometer was developed. It measures the surface temperature of arbitrary nongray ceramics by curve fitting a spectrum in this spectral region to a Planck function of temperature T. This function of T is modified by the surface spectral emissivity. The emissivity function was derived experimentally from additional spectra that were obtained by using an auxiliary radiation source and from application of Kirchhoff's law. This emissivity was verified by results that were obtained independently by using electromagnetic and solid-state theories. In the presence of interfering reflected radiation this general pyrometry improves the accuracy of the measured temperature by measuring an additional spectrum that characterizes the interfering radiation source.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Thermosense XIV; Proceedings of the International Conference on Thermal Sensing and Imaging Diagnostic Applications, Orlando, FL, Apr. 22-24, 1992 (A94-12410 02-35); p. 260-270.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Publication Date: 2011-08-24
    Description: Binary phase-only filters (BPOFs) have generated much study because of their implementation on currently available spatial light modulator devices. On polarization-rotating devices such as the magneto-optic spatial light modulator (SLM), it is also possible to encode binary amplitude information into two SLM transmission states, in addition to the binary phase information. This is done by varying the rotation angle of the polarization analyzer following the SLM in the optical train. Through this parameter, a continuum of filters may be designed that span the space of binary phase and amplitude filters (BPAFs) between BPOFs and binary amplitude filters. In this study, we investigate the design of optimal BPAFs for the key correlation characteristics of peak sharpness (through the peak-to-correlation energy (PCE) metric), signal-to-noise ratio (SNR), and discrimination between in-class and out-of-class images. We present simulation results illustrating improvements obtained over conventional BPOFs, and trade-offs between the different performance criteria in terms of the filter design parameter.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Optical Pattern Recognition 3, (SPIE Vol. 1701); p. 128-139
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Publication Date: 2011-08-24
    Description: Two types of neural networks were used to evaluate acousto-ultrasonic (AU) data for material characterization and mechanical reponse prediction. The neural networks included a simple feedforward network (backpropagation) and a radial basis functions network. Comparisons of results in terms of accuracy and training time are given. Acousto-ultrasonic (AU) measurements were performed on a series of tensile specimens composed of eight laminated layers of continuous, SiC fiber reinforced Ti-15-3 matrix. The frequency spectrum was dominated by frequencies of longitudinal wave resonance through the thickness of the specimen at the sending transducer. The magnitude of the frequency spectrum of the AU signal was used for calculating a stress-wave factor based on integrating the spectral distribution function and used for comparison with neural networks results.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Computing Systems in Engineering (ISSN 0956-0521); 3; 1-4; p. 539-544.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Publication Date: 2011-08-24
    Description: Daily measurements of the soil dielectric properties at 5 and 10 cm were obtained at five locations throughout the First ISLSCP Field Experiment (FIFE) test site during the 1987 intensive field campaigns (IFCs). An automated vector voltmeter was used to monitor the complex electrical impedance, at 10 MHz, of cylindrical volumes of soil delineated by specially designed soil moisture probes buried at these locations. The objective of this exercise was to test the hypothesis that the soil impedance is sensitive to the moisture content of the soil and that the imaginary part (that is, capacitive reactance) can be used to calculate the volumetric water content of the soil. These measurements were compared with gravimetric samples collected at these locations by the FIFE staff science team.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 97; D17; p. 18,969-18,977.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Publication Date: 2011-08-24
    Description: The radiometric accuracy of a sensor is adversely affected by scene polarization if its optical system is sensitive to polarization. Tests performed on the reflective bands of the NS001 Thematic Mapper simulator, an aircraft multispectral scanner, show that it is very sensitive to the polarization state of the incoming radiations. For 100 percent linearly polarized light, errors in the measured intensity vary from -40 to +40 percent, depending on the scan angle and spectral band. To estimate polarization-induced errors in the intensity measured at aircraft level, the intensity and polarization of the atmospheric radiances were simulated using a realistic earth-atmosphere radiative transfer model. For the polarization of atmospheric radiances in the solar meridian plane over a vegetated target, intensity errors may range from -10 to + 10 percent. The polarization-induced errors are highest in the shortest NS001 spectral band (0.450-0.525 microns) because of large atmospheric polarizations contributed by Rayleigh particles and small diluting effects caused by the small contributions of weakly polarized radiations coming from aerosols and the surface. Depending on the illumination and view angles, the errors in derived surface reflectance due to the radiance errors can be very large. In particular, for large off-nadir view angles in the forward scattered direction when the sun is low, the relative errors in the derived surface reflectance can be as large as 4 to 5 times the relative error in the radiances. Polarization sensitivity errors cannot be neglected for the shorter wavelengths when the surface reflectance contribution to atmospheric radiances is very small.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 97; D17; p. 18,815-18,827.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Publication Date: 2011-08-24
    Description: The NASA DC-8 AIRSAR instrument has been augmented with a pair of C-band antennas displaced across track to form an interferometer sensitive to topographic variations of the earth's surface. During the 1991 DC-8 flight campaign, data were acquired over several sites in the U.S. and Europe, and topographic maps were produced from several of these flight lines. Analysis of the results indicate that statistical errors are in the 2-4 m range, while systematic effects due to aircraft motion are in the 10-20 m range. Initial results from development of a second generation processor at JPL show that aircraft motion compensation algorithms reduce the systematic variations to 2 m, while the statistical errors are reduced to 2-3 m.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Geoscience and Remote Sensing (ISSN 0196-2892); 30; 5; p. 933-940.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Publication Date: 2011-08-24
    Description: Nonintrusive measurements of density and temperature and their turbulent fluctuation levels have been obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment compare favorably with previous measurements obtained in the same facility from conventional probes and an earlier spectroscopic technique.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optics Letters (ISSN 0146-9592); 17; 22; p. 1614-1616.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Publication Date: 2011-08-24
    Description: Results obtained from five techniques for measuring gas-phase ammonia at low concentration in the atmosphere are compared. These methods are: (1) a photofragmentation/laser-induced fluorescence (PF/LIF) instrument; (2) a molybdenum oxide annular denuder sampling/chemiluminescence detection technique; (3) a tungsten oxide denuder sampling/chemiluminescence detection system; (4) a citric-acid-coated denuder sampling/ion chromatographic analysis (CAD/IC) method; and (5) an oxalic-acid-coated filter pack sampling/colorimetric analysis method. It was found that two of the techniques, the PF/LIF and the CAD/IC methods, measured approximately 90 percent of the calculated ammonia added in the spiking tests and agreed very well with each other in the ambient measurements.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 97; D11,; 11
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Publication Date: 2011-08-24
    Description: The water vapor-induced propagation delay experienced by a radio signal traversing the atmosphere is characterized by the Slant Path Atmospheric Refraction Calibrator (SPARC), which measures the difference in the travel times between an optical and a microwave signal propagating along the same atmospheric path with an accuracy of 15 picosec or better. Attention is given to the theoretical and experimental issues involved in measuring the delay induced by water vapor; SPARC measurements conducted along a 13.35-km ground-based path are presented, illustrating the instrument's stability, precision, and accuracy.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Geoscience and Remote Sensing (ISSN 0196-2892); 30; 3, Ma; 462-471
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-24
    Description: This microwave holography technique utilizes the Fourier transform relation between the complex far field radiation pattern of an antenna and the complex aperture field distribution. Resulting aperture phase and amplitude distribution data can be used to precisely characterize various crucial performance parameters, including panel alignment, panel shaping, subreflector position, antenna aperture illumination, directivity at various frequencies, and gravity deformation effects. The methodology of data processing presented here was successfully applied to the Deep Space Network (DSN) 34-m beam waveguide antennas. The antenna performance was improved at all operating frequencies by reducing the main reflector mechanical surface rms error to 0.43 mm. At Ka-band (32 GHz), the estimated improvement is 4.1 dB, resulting in an aperture efficiency of 52 percent. The performance improvement was verified by efficiency measurements and additional holographic measurements.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Microwave Theory and Techniques (ISSN 0018-9480); 40; 6, Ju; 1294-130
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Publication Date: 2011-08-24
    Description: The Geophysics Directorate's 8-bit multispectral color-composite image display technique has been installed on the Satellite Data Processing System at the German Military Geophysical Office in Traben-Trarbach, Germany. The technique simulates 24-bit full-color composites on 8-bit color workstations, combining image data from the NOAA multispectral Advanced Very High Resolution Radiometer. The real-time application of this technique to operational satellite data is discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: American Meteorological Society, Bulletin (ISSN 0003-0007); 73; 6, Ju
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Publication Date: 2011-08-24
    Description: A control system based on a two-channel narrow-band LMS algorithm is used to isolate periodic vibration at low frequencies on a structure composed of a rigid top plate mounted on a flexible receiving plate. The control performance of distributed PVDF error sensors and accelerometer point sensors is compared. For both sensors, high levels of global reduction, up to 32 dB, have been obtained. It is found that, by driving the PVDF strip output voltage to zero, the controller may force the structure to vibrate so that the integration of the strain under the length of the PVDF strip is zero. This ability of the PVDF sensors to act as spatial filters is especially relevant in active control of sound radiation. It is concluded that the PVDF sensors are flexible, nonfragile, and inexpensive and can be used as strain sensors for active control applications of vibration isolation and sound radiation.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Sound and Vibration (ISSN 0022-460X); 155; 1, Ma; 177-184
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Publication Date: 2011-08-24
    Description: The longest-wavelength quantum-well IR photodetector ever achieved, with a cutoff wavelength of 19 microns, is demonstrated. Detailed measurements and an in-depth analysis of the noise, optical gain, detectivity, quantum efficiency, and quantum-well escape probability are also discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Applied Physics (ISSN 0021-8979); 71; 10, M; 5130-513
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Publication Date: 2011-08-24
    Description: Saturation of a transition of the OH molecule in high-pressure flames is demonstrated by obtaining saturation curves in C2H6/O2/N2 laminar flames at 1, 6.1, 9.2, and 12.3 atm. Quantitative fluorescence measurements of OH number density at pressures to 12.3 atm are presented. To assess the efficacy of the balanced cross-rate model for high-pressure flames, laser-saturated fluorescence measurements, which were calibrated in an atmospheric-pressure flame, are compared with absorption measurements at 3.1 and 6.1 atm. At 3.1 atm the absorption and fluorescence measurements compare well. At 6.1 atm, however, the concentrations given by lasre-saturated fluorescence are about 25 percent lower than the absorption values, indicating some depletion of the laser-coupled levels beyond that at atmospheric pressure. By using a reasonable estimate for the finite sensitivity to quenching, it is anticipated that fluorescence measurements that are calibrated at 1 atm can be applied to flames at about 10 atm with absolute errors within +/- 50 percent.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 31; 1511-152
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Publication Date: 2011-08-24
    Description: The theory and measurement of angle-resolved scatter are described. Values of rms roughness that were obtained by using this technique to characterize four different materials are compared with values that were obtained by using a total integrated scatter measuring instrument, an optical profiler, and a mechanical profiler. The spatial frequency bandwidths and modulation transfer functions of the four instruments are different, and results are described in light of these differences.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 31; 1426-143
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Publication Date: 2011-08-24
    Description: A coherent 1-micron Nd:YAG lidar system is employed to measure directly the reduced spatial coherence length rho 0 of the lidar returns caused by atmospheric turbulence. The experiments were conducted by using a 2 x 2 heterodyne detector array, which permitted real-time spatial correlation measurements of the lidar returns at two different detector spacings. The spatial correlation coefficients and spatial coherence length of the lidar returns from a hard target were measured during a day-to-night time period when the atmospheric turbulence parameter, Cn-squared, was measured to vary from 2 x 10 exp -13 to 2 x 10 exp -4 m exp -2/3. These directly measured values of rho 0 as a function of Cn-squared were found to be in good agreement with theoretical predictions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 31; 1505-151
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Publication Date: 2011-08-24
    Description: The first experimental observation of a change in the director azimuthal angle due to applied shear stress is reported in a sample configuration involving a liquid-crystal-coated top surface exposed directly to gas flow. The electrooptic response caused by the shear stress is large, fast, and reversible. These findings are relevant to the use of liquid crystals in boundary layer investigations on wind tunnel models.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Physics Letters (ISSN 0003-6951); 60; 1954-195
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Publication Date: 2011-08-24
    Description: Characteristics of a liquid crystal system, comprised of a shear-sensitive cholesteric-monomer liquid crystal thin-film coated on a liquid-crystal polymer substrate, are described. The system provides stable Grandjean texture, a desirable feature for shear-stress measurements using selective reflection from the monomer liquid-crystal helix structure. Impingement of gas or air flow on the monomer liquid-crystal free surface changes the wavelength of the selective reflection for an incident white light from red toward blue with increase in the rate of gas flow. The contrast of the selectively reflected light improves considerably by providing a thin black coating of about 5 microns at the monomer-polymer interface. The coating thickness is such that the steric interactions are still sufficiently strong to maintain Grandjean texture. For a small angle of incidence of a monochromatic light, the measurement of the reflected light intensity normal to the monomer-polymer liquid-crystal interface enables the determination of the wavelength for selective reflection as a function of the gas-flow differential pressure applied in the plane of the interface. The variation of the wavelength with the pressure is linear with a slope of about 2 nm/mmHg. Furthermore, the shear-stress effects are reversible unlike for monomer liquid crystal-metal systems used for flow visualization on wind-tunnel model surfaces. The present system offers a suitable method for direct on-line measurement of shear stress field from measurements of the wavelength for selective reflection for an incident white light.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments (ISSN 0034-6748); 63; 225-229
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Publication Date: 2011-08-24
    Description: Modern laser-spectroscopic techniques usually incorporate one or more laser beams and depend on their radiative interaction with some spectroscopic feature of the gas. Attention is given to laser absorption, laser-induced fluorescence, Rayleigh scattering, and Raman scattering. Consideration is given to UV Rayleigh scattering applied to aerodynamic flows to obtain images of a supersonic boundary layer that show instantaneous turbulent structures at a level of detail not achieved by any other practical method.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Aerospace America (ISSN 0740-722X); 30; 11; p. 20-24.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Publication Date: 2011-08-24
    Description: The exact field solution of a step-index profile fiber was used to determine the injection efficiency of a thin-film distribution of polarized sources located in the cladding of an optical fiber. Previous results for random source orientation were confirmed. The behavior of the power efficiency, P(eff), of a polarized distribution of sources was found to be similar to the behavior of a fiber with sources with random orientation. However, for sources polarized in either the x or y direction, P(eff) was found to be more efficient.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optical Engineering (ISSN 0091-3286); 31; 10; p. 2213-2217.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Publication Date: 2011-08-24
    Description: The application of interferometry techniques to analysis of aerodynamic flows on rotorcraft is reviewed, with emphasis on those studies which give insight into the character of the complex flows on helicopter rotor blades. In particular, blade-vortex interaction, dynamic stall, and transonic flow on rotor blades are reviewed, showing how interferometry offers new insight into the basic flow characteristics of these flows and presenting some of the correlations that have been made with the results of computational analysis.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optics and Lasers in Engineering (ISSN 0143-8166); 17; 3-5; p. 121-146.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Publication Date: 2011-08-24
    Description: Attention is given to the use of a short-length multimode sapphire rod as an extension to a conventional Michelson interferometric configuration, but with operation of Fabry-Perot cavity-based sensor element type. The performance of such a device as an interferometric sensor is demonstrated for a case where the interference between the reflections from the sapphire-air interface and an air-metallic surface is inspected for microdisplacements of the metallic surface. A detailed account is given of the sensor's fabrication procedure; results are presented for the detection of surface-acoustic waves.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Review of progress in quantitative nondestructive evaluation. Vol. 11A; Proceedings of the 18th Annual Review, Brunswick, ME, July 28-Aug. 2, 1991 (A93-18576 05-38); p. 1111-1114.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Publication Date: 2011-08-24
    Description: A hemispherical open resonator has previously been used to make relative comparisons of the surface resistivity of metallic thin-film samples in the submillimeter wavelength region. This resonator is fed from a far-infrared laser via a small coupling hole in the center of the concave spherical mirror. The experimental arrangement, while desirable as a coupling geometry for monitoring weak emissions from the cavity, can lead to the introduction of spurious modes into the cavity. Sources of these modes are identified, and a simple alteration of the experimental apparatus to eliminate such modes is suggested.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments (ISSN 0034-6748); 63; 267
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Publication Date: 2013-08-31
    Description: Progress made in the processing and characterization of 3C-SiC for high temperature sensor applications is reviewed. Piezoresistance properties of silicon carbide and the temperature coefficient of resistivity of n-type beta-SiC are presented. In addition, photoelectrical etching and dopant selective etch-stops in SiC and high temperature Ohmic contacts for n-type beta-SiC sensors are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center, The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments; p 255-264
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Publication Date: 2013-08-31
    Description: With the widespread availability of video digitizers and cheap personal computers, the use of computer vision as an experimental tool is becoming common place. These systems are being used to make a wide variety of measurements that range from simple surface characterization to velocity profiles. The Sub-Pixel Digital Image Correlation technique has been developed to measure full field displacement and gradients of the surface of an object subjected to a driving force. The technique has shown its utility by measuring the deformation and movement of objects that range from simple translation to fluid velocity profiles to crack tip deformation of solid rocket fuel. This technique has recently been improved and used to measure the surface displacement field of an object at high temperature. The development of a PC based Sub-Pixel Digital Image Correlation system has yielded an accurate and easy to use system for measuring surface displacements and gradients. Experiments have been performed to show the system is viable for measuring thermal strain.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center, The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments; p 237-243
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Publication Date: 2013-08-31
    Description: Once an installed strain gage is connected to a strain indicating device and the instrument is balanced, a subsequent change in temperature of the gage installation will generally produce a resistance change in the gage. This purely temperature-induced resistance will be registered by the indicating device as a strain and is referred to as 'apparent strain' to distinguish it from strain due to applied stress. One desirable technique for apparent strain compensation is to employ two identical gages with identical mounting procedures which are connected with a 'half bridge' configuration where gages see the same thermal environment but only one experiences a mechanical strain input. Their connection in adjacent arms of the bridge will then balance the thermally induced apparent strains and, in principle, only the mechanical strain remains. Two approaches that implement this technique are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments; p 211-222
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Publication Date: 2013-08-31
    Description: Since 1987, a very substantial amount of R&D has been conducted in an attempt to develop reliable strain sensors for the measurements of structural strains during ground testing and hypersonic flight, at temperatures up to at least 2000 deg F. Much of the effort has been focused on requirements of the NASP Program. This presentation is limited to the current sensor development work and characterization studies carried out within that program. It is basically an assessment as to where we are now and what remains to be done in the way of technical accomplishments to meet the technical challenges posed by the requirements and constraints established for the NASP Program. The approach for meeting those requirements and constraints has been multi-disciplinary in nature. It was recognized early on that no one sensor could meet all these requirements and constraints, largely because of the large temperature range (cryogenic to at least 2000 deg F) and many other factors, including the most challenging requirement that the sensor system be capable of obtaining valid 'first cycle data'. Present candidate alloys for resistance-type strain gages include Fe-Cr-Al and Pd-Cr. Although they have superior properties regarding withstanding very high temperatures, they exhibit large apparent strains that must either be accounted for or cancelled out by various techniques, including the use of a dual-element, half-bridge dummy gage, or electrical compensation networks. A significant effort is being devoted to developing, refining, and evaluating the effectiveness of those techniques over a broad range in temperature and time. In the quest to obtain first-cycle data, ways must be found to eliminate the need to prestabilize or precondition the strain gage, before it is attached to the test article. It should be noted that present NASP constraints do not permit prestabilization of the sensor, in situ. Gages are currently being 'heat treated' during manufacture in both the wire- and foil-type resistance strain gages, and evaluation is in progress. In addition, the 'gage-on-shim' concept is being revisited. That concept will permit heat treatment of the gage during manufacture, before attachment on the test article. Also, it may permit the individual calibration of each gage regarding gage factor and apparent strain. Candidate alloys for the NASP include titanium metal-matrix and carbon-carbon composites. Although those materials have very attractive properties at elevated temperatures in terms of strength and weight, they pose significant attachment problems. Methods for making reliable strain gage and thermocouple attachments to them are currently under development. Experience to date indicates that Rokide attachment of the sensor directly to the protective coating is easier than to the base material itself. However, interpreting strain data from gages attached in this way may prove difficult because of possible cracks in the coating that form 'islands' and the mobility of those 'islands'. It is concluded, therefore, that major technical challenges lie ahead as we proceed to meet the stringent strain sensor requirements and constraints of the NASP Program.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center, The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments; p 127-169
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Publication Date: 2013-08-31
    Description: The Calspan electron beam fluorescence (EBF) measurement system is described along with the results of measurements made in hypersonic flow. Numerous self-emitting metallic species were identified, many of which may be associated with an aging/erosion process within the B30HST. Because there were only 16 tunnel runs, it was only possible to obtain spectral measurements over a limited range of wavelengths and time sampling periods. Many spectral features of the flow remain uninvestigated. Because flow self-emission is important to all optical diagnostic techniques, it is recommended that additional spectral studies by performed. The three electron beam-excited species that were identified are nitrogen, helium, and nitric oxide. The high metallic radiation background interfered with attempts to obtain the time-wise variation of N2 density and He radiation with the optical fiber/PMT channels. In the case of the N2 density measurements the result of interference was increased uncertainty. Unfortunately, the interference caused the time-wise He measurements to fail completely. It is recommended that the electron beam be modulated to provide discrimination against the background radiation in future N2 density measurements. Careful data reduction produced useful measurements of N2 vibrational temperature, even though the high background from metallic species significantly increased measurement uncertainty. Perhaps the recommended additional spectral studies would reveal N2(+) First Negative System band-pair regions having less background. Detection of the He arrival was easily accomplished with the spectrometer/array detector system. Because of this, it is recommended that this means of detecting He arrival be used in the future. With proper calibrations of the system an He number density could be obtained. Although the flow conditions were out of limits for the run in which the NO spectrum was recorded, the usefulness of the NO spectrum for determination of free-stream rotational temperature was demonstrated and should be exploited in future experiments. Indeed, based on the strong NO signals, it is recommended that lower resolution NO spectra be obtained to provide a measure of NO vibrational temperature in the same manner that the N2 temperature was obtained.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center, The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments; p 305-320
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Publication Date: 2013-08-31
    Description: The Instrumentation and Control Technology Division at NASA Lewis Research Center has developed a high performance optical strain measurement system for high temperature applications using wires and fibers. The system is based on Yamaguchi's two-beam speckle-shift strain measurement technique. The system automatically calculates surface strains at a rate of 5 Hz using a digital signal processor in a high speed micro-computer. The system is fully automated, and can be operated remotely. This report describes the speckle-shift technique and the latest NASA system design. It also shows low temperature strain test results obtained from small diameter tungsten, silicon carbide, and sapphire specimens. These specimens are of interest due to their roles in composite materials research at NASA Lewis.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center, The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments; p 245-249
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Publication Date: 2013-08-31
    Description: Recent progress in techniques employed in the measurement of very high heat-transfer rates in reentry-type facilities at the Arnold Engineering Development Center (AEDC) is described. These advances include thermal analyses applied to transducer concepts used to make these measurements; improved heat-flux sensor fabrication methods, equipment, and procedures for determining the experimental time response of individual sensors; performance of absolute heat-flux calibrations at levels above 2,000 Btu/cu ft-sec (2.27 kW/cu cm); and innovative methods of performing in-situ run-to-run characterizations of heat-flux probes installed in the test facility. Graphical illustrations of the results of extensive thermal analyses of the null-point calorimeter and coaxial surface thermocouple concepts with application to measurements in aerothermal test environments are presented. Results of time response experiments and absolute calibrations of null-point calorimeters and coaxial thermocouples performed in the laboratory at intermediate to high heat-flux levels are shown. Typical AEDC high-enthalpy arc heater heat-flux data recently obtained with a Calspan-fabricated null-point probe model are included.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center, The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments; p 31-50
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Publication Date: 2013-08-31
    Description: For the last two years an engineering team in the Program Development Office at MSFC has been doing design studies for the proposed Inner Magnetospheric Imager (IMI) mission. This team had a need for more information about the instruments that this mission would carry so that they could get a better handle on instrument volume, mass, power, and telemetry needs as well as information to help assess the possible cost of such instruments and what technology development they would need. To get this information, an extensive literature search was conducted as well as interviews with several members of the IMI science working group. The results of this heritage survey are summarized below. There was also a need to evaluate the orbits proposed for this mission from the stand point of their suitability for viewing the various magnetospheric features that are planned for this mission. This was accomplished by first, identifying the factors which need to be considered in selecting an orbit, second, translating these considerations into specific criteria, and third, evaluating the proposed orbits against these criteria. The specifics of these criteria and the results of the orbit analysis are contained in the last section of this report.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Alabama Univ., 1992 NASA(ASEE Summer Faculty Fellowship Program; 5 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Publication Date: 2013-08-31
    Description: The use of molecular Rayleigh scattering for measurements of gas density and temperature is evaluated. The technique used is based on the measurement of the spectrum of the scattered light, where both temperature and density are determined from the spectral shape. Planar imaging of Rayleigh scattering from air using a laser light sheet is evaluated for ambient conditions. The Cramer-Rao lower bounds for the shot-noise limited density and temperature measurement uncertainties are calculated for an ideal optical spectrum analyzer and for a planar mirror Fabry-Perot interferometer used in a static, imaging mode. With this technique, a single image of the Rayleigh scattered light can be analyzed to obtain density (or pressure) and temperature. Experimental results are presented for planar measurements taken in a heated air stream.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center, The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments; p 355-374
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Publication Date: 2013-08-31
    Description: A fiber optic microphone, based on the principle of the fiber optic lever, features small size, extended bandwidth, and capability to operate at high temperatures. These are requirements for measurements in hypersonic flow. This paper describes the principles of operation of fiber optic sensors, a discussion of the design of a fiber optic microphone, the functional elements and packaging techniques of the optoelectronic circuitry, and the calibration techniques used in the development of the high temperature fiber optic microphone.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments; p 301-304
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Publication Date: 2013-08-31
    Description: This microwave holography technique utilizes the Fourier transform relation between the complex far field radiation pattern of an antenna and the complex aperture field distribution. Resulting aperture phase and amplitude distribution data can be used to precisely characterize various crucial performance parameters, including panel alignment, panel shaping, subreflector position, antenna aperture illumination, directivity at various frequencies, and gravity deformation effects. The methodology of data processing presented here was successfully applied to the Deep Space Network (DSN) 34-m beam waveguide antennas. The antenna performance was improved at all operating frequencies by reducing the main reflector mechanical surface rms error to 0.43 mm. At Ka-band (32 GHz), the estimated improvement is 4.1 dB, resulting in an aperture efficiency of 52 percent. The performance improvement was verified by efficiency measurements and additional holographic measurements.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommunications and Data Acquisition Report; p 235-252
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Publication Date: 2013-08-31
    Description: A device is described which provides the value of date coordinated universal time (date UTC) to the JPL Network Operations Control Center, Real Time (NOCC-RT) facility. The NOCC-RT is the real time portion of the NOCC upgrade task. The time scale is generated in the NOCC-RT clock processor; however, there is a continuous reference to UTC, as realized by the National Institute of Standards and Technology and transmitted by Earth orbiting satellites. An important functional design requirement is the 99.9 pct. availability.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommunications and Data Acquisition Report; p 214-221
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Publication Date: 2013-08-31
    Description: Described here is the application of the microwave holography technique to Deep Space Station (DSS) 13. The project goal of obtaining a rigging angle surface rms error of 0.43 mm or better was met. The Jet Propulsion Laboratory-developed holography algorithms enabled a reduction of the surface error of the DSS-13 antenna from the optically set 0.83 mm axial rms error down to 0.40 mm rms, providing an additional 4.1 dB of performance at 32 GHz.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommunications and Data Acquisition Report; p 253-270
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2013-08-31
    Description: The IMAX camera system is used to record on-orbit activities of interest to the public. Because of the extremely high resolution of the IMAX camera, projector, and audio systems, the audience is afforded a motion picture experience unlike any other. IMAX and OMNIMAX motion picture systems were designed to create motion picture images of superior quality and audience impact. The IMAX camera is a 65 mm, single lens, reflex viewing design with a 15 perforation per frame horizontal pull across. The frame size is 2.06 x 2.77 inches. Film travels through the camera at a rate of 336 feet per minute when the camera is running at the standard 24 frames/sec.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center, First International Microgravity Laboratory Experiment Descriptions; p 265-269
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...