ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (120)
  • 1980-1984  (120)
  • 1984  (69)
  • 1982  (51)
  • 1
    Publication Date: 2011-08-18
    Description: A diode-laser-based, ultrahigh resolution IR heterodyne spectrometer for laboratory and field use has been developed for operation between 7.5 and 8.5 microns. The local oscillator is a PbSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed-cycle cooler. The laser output frequency is controlled and stabilized using a high-precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. The system largely employs reflecting optics to minimize losses from internal reflection and absorption and to eliminate chromatic effects. Spectral analysis of the diode-laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the IR spectral regions over which useful heterodyne operation can be achieved. Observations have been made of atmospheric N2O, O3, and CH4 between 1170 and 1200/cm, using both a single-frequency swept IF channel and a 64-channel RF spectral line receiver with a total IF coverage of 1600 MHz.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 21; Jan. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-19
    Description: Attention is given to 1.2 years of data from two Michelson-Gale long fluid tiltmeters, one long center pressure tiltmeter, and a shallow borehole tiltmeter, which have been in operation at Pinon Flat Observatory in Southern California. The most stable tilt record shows a secular rate of 0.28 microrad/a, which may be real. Comparisons undertaken among instruments have identified more and less successful measurement techniques. It is concluded that even the best existing sensors must be improved in order to measure continuous tectonic motions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Geophysical Research Letters (ISSN 0094-8276); 11; 963-966
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2016-06-07
    Description: A redesign of the antenna electronics package for the NBS/GPS C/A receiver has resulted in significantly reduced cost and improved performance. Major improvements include a simplified and more reliable multiplier/mixer, elimination of all twelve piston trimmer tuning capacitors in the original design, elimination of expensive bandpass filters, less expensive antenna and a simplified packaging scheme.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 467-474
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-13
    Description: Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Instrumentation in astronomy IV; Fourth Conference; Mar 08, 1982 - Mar 10, 1982; Tucson, AZ
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-18
    Description: A new type of bolometer detector for the millimeter and submillimeter spectral range is described. The bolometer is constructed of silicon using integrated circuit fabrication techniques. Ion implantation is used to give controlled resistance vs temperature properties as well as extremely low 1/f noise contacts. The devices have been tested between 4.2 and 0.3 K. The best electrical NEP measured is 4 x 10 to the -16th W/Hz to the 1/2 at 0.35 K between 1- and 10-Hz modulation frequency. This device had a detecting area of 0.25 sq cm and a time constant of 20 msec at a bath temperature of 0.35 K.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 910-914
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2016-06-07
    Description: The method of ion storage provides a basis for excellent time and frequency standards. This is due to the ability to confine ions for long periods of time without the usual perturbations associated with confinement (e.g., wall shifts). In addition, Doppler effects can be greatly suppressed. The use of stored ions for microwave frequency standards and the future possibilities for an optical frequency standard based on stored ions are addressed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 49-58
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2014-09-13
    Description: A three factor (spectral, spatial, and radiometric resolution), two level (TM and MSS) analysis of variance (ANOVA) approach allowed evaluation of the effects of each factor individually and in all possible combinations. Digital classification accuracy was used as the figure of merit. Nine study sites in Washington, D.C. each of approximately 256 x 256 TM pixels, were randomly selected from the full scene for analysis. These results strongly suggest that the quantization level improvements and the addition of new spectral bands in the visible and middle IR regions (both afforded by the TM sensor design) can result in improved capabilities to accurately delineate land cover categories using a per point Gaussian maximum likelihood classifier. On the other hand, results indicate that the increase in spatial resolution to 30m does not significantly enhance classification accuracy. The spatial result points to an inherent limitation of a per point classifier and to the need to improve data analysis techniques to handle high spatial resolution data.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: LANDSAT-4 Sci. Invest. Summ., Including Dec. 1983 Workshop Results, Vol. 2; p 93-97
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-06-28
    Description: A digital optical torquemeter system designed for applications at high rotational speeds was fabricated and tested for zero stability at speeds up to 20,000 rpm. Data obtained in a spin rig and with simulated inputs demonstrate that the system is capable of measuring torque bar twist to within 0.03 degrees at speeds of 30,000 rpm. The optical system uses fiber optic bundles to transmit light to the torque bar and to silicon avalanche detectors. The system is microcomputer based and provides measurements of average torque and torque as a function of angular shaft position. The torquemeter requires no bearings or other contact between the rotating torque bar and the nonrotating optics, and tolerates movement of the torque bar as large as 1 mm relative to the optics.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-82914 , E-1189 , NAS 1.15:82914
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-28
    Description: The retarding ion mass spectrometer (RIMS) for Dynamics Explorer-1 is an instrument designed to measure the details of the thermal plasma distribution. It combines the ion temperature determining capability of the retarding potential analyzer with the compositional capabilities of the mass spectrometer and adds multiple sensor heads to sample all directions relative to the spacecraft ram direction. This manual provides a functional description of the RIMS, the instrument calibration, and a description of the commands which can be stored in the instrument logic to control its operation.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-82484 , NAS 1.15:82484
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-06-28
    Description: A new microbolometer for far-infrared detection has been fabricated that allows an increase in sensitivity of a factor of 4 over the best previously reported bolometer. By suspending the detector in the air above its substrate, a reduction in the thermal conductance out of the device by a factor of 5 has been achieved. At a modulation frequency of 100 kHz this microbolometer has an electrical noise equivalent power 28 pW/sq rt Hz. A thermal model is also presented that accurately fits the response of the detector.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Physics Letters (ISSN 0003-6951); 44; 153-155
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...