Abstract The liquid thermal conductivities of the CFC alternatives, HFC-125, and HCFC-141b measured by a transient hot-wire apparatus with one bare platinum wire are reported in the temperature ranges from 193 to 333 K (HFC-125, CHF2, CF3) and from 193 to 393 K (HCFC-141b,CCI2F-CF3), in the pressure ranges from 2 to 30 MPa (HFC-125) and from 0.1 to 30 MPa (HCFC-141b), respectively. The results have been estimated to have an accurancy of ±0.5%. The liquid thermal conductives obtained have been correlated by a polynomial of temperature and pressure which can represent the experimental results within the standard deviations of 0.49% for HFC-125 and 0.46% for HCFC-141b, respectively.