ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 17 (1996), S. 279-292 
    ISSN: 1572-9567
    Keywords: CFC-alternatives ; HCFC-141b ; HFC-125 ; thermal conductivity ; transient hot-wire method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The liquid thermal conductivities of the CFC alternatives, HFC-125, and HCFC-141b measured by a transient hot-wire apparatus with one bare platinum wire are reported in the temperature ranges from 193 to 333 K (HFC-125, CHF2, CF3) and from 193 to 393 K (HCFC-141b,CCI2F-CF3), in the pressure ranges from 2 to 30 MPa (HFC-125) and from 0.1 to 30 MPa (HCFC-141b), respectively. The results have been estimated to have an accurancy of ±0.5%. The liquid thermal conductives obtained have been correlated by a polynomial of temperature and pressure which can represent the experimental results within the standard deviations of 0.49% for HFC-125 and 0.46% for HCFC-141b, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...