ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (250)
  • Other Sources
  • Electrical Engineering, Measurement and Control Technology  (250)
Collection
  • Articles  (250)
  • Other Sources
Journal
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 62 (1991), S. 1867-1868 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A method for measuring the thickness of opaque parts to within 4 μm by inserting a small scale into the part or along side has been developed. A combination digital and analog scale is used to determine the length of the scale when viewed from the edge. This scale should be useful for applications where only one surface is exposed during machining or polishing, and where the side is also inaccessible.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 1103-1105 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A negative-ion source extraction model has been formulated and implemented that explicitly considers the motion of positive ions and the volume generation of negative ions. It is found that (1) for high-beam currents, the beam current is limited by a transverse space-charge limit, meaning that an increase in negative-ion density at the extraction sheath will result in a lower-beam current (this result is universally observed at high-beam current); (2) there is a saddle point with a potential barrier preventing most volume-produced negative ions from being extracted [the combination of (1) and (2) indicates that most of the negative ions being created do not find their way into the beam]; (3) the introduction of cesium may cause an increase in the transverse space-charge limit; (4) cesium also results in an increase in the fraction of volume-produced negative ions that are extracted; (5) cesium may also result in reduction of extracted electrons by producing a less negative bias on the plasma electrode with respect to the plasma, thus allowing the transverse space-charge limit budget to be taken up virtually totally by the ions. [The combination of (3)–(5) represents the way an actual increase in the beam current can be achieved]; (6) a strong ion time scale sheath instability due to violation of the Bohm criteria produces an anomalous ion temperature, which increases with the beam current, as routinely seen in measurements; and (7) the introduction of cesium may result in a reduction in this instability. These insights may lead to improvements in volume negative-ion sources.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 5019-5031 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A new rheometer is described. It consists of a transducer unit supplied with an electric impedance analyzing unit. The transducer unit converts a mechanical impedance into an electrical impedance by the piezoelectric effect. A detailed quantitative analysis of the interaction between the sample and the transducer is given. The real and imaginary parts of the shear modulus of a viscoelastic sample can be found in the frequency range of 1 mHz–50 kHz, modulus range of 0.1 MPa–10 GPa, and the temperature range of 150–300 K. The sample volume is 0.3 cm3 and the strain amplitude is exceedingly small. The small size of the transducer allows for good temperature control and equilibration. It has a simple construction based on inexpensive components. Results on the supercooled liquid 2-metyl-2,4-pentandiol at the glass transition obtained by the method are included. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 2012-2018 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory will use the 25 MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility. The choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. Although direct-extraction negative ion sources are clearly desirable, the ion formation efficiencies are often too low for practical consideration; for this situation, positive ion sources, in combination with charge exchange, are the logical choice. The high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the facility because of its low emittance, relatively high ionization efficiencies, and species versatility, and because it has been engineered for remote installation, removal, and servicing as required for safe handling in a high-radiation-level ISOL facility. The source will be primarily used to generate ion beams from elements with intermediate to low electron affinities. Prototype plasma-sputter negative ion sources and negative surface-ionization sources are under design consideration for generating radioactive ion beams from high-electron-affinity elements. The design features of these sources and expected efficiencies and beam qualities (emittances) will be described in this report.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A review of the diagnostics used at Sandia National Laboratories to measure the parameters of intense lithium ion-beam hohlraum target experiments on Particle Beam Fusion Accelerator II will be presented. This diagnostic package contains an extensive suite of x-ray spectral and imaging diagnostics that enable measurements of target temperature and x-ray output. The x-ray diagnostics include time-integrated and time-resolved pinhole cameras, energy-resolved one-dimensional streaked imaging diagnostics, time-integrated and time-resolved grazing incidence spectrographs, a transmission grating spectrograph, an elliptical crystal spectrograph, a bolometer array, an 11- element x-ray diode array, and an 11-element PIN diode detector array. The incident Li beam symmetry and an estimate of incident Li beam power density can be measured from ion beam-induced characteristic x-ray line emission and neutron emission. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 1391-1391 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility. The choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. Although direct-extraction negative ion sources are clearly desirable, the ion formation efficiencies are often too low for practical consideration; for this situation, positive ion sources, in combination with charge exchange, are the logical choice. The high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the facility because of its low emittance, relatively high ionization efficiencies and species versatility, and because it has been engineered for remote installation, removal and servicing as required for safe handling in a high-radiation-level ISOL facility. The source will be primarily used to generate ion beams from elements with intermediate to low ionization potentials. Prototype plasma-sputter negative ion sources and negative surface-ionization sources are under design consideration for generating radioactive ion beams from high-electron-affinity elements. The design features of these sources and expected efficiencies and beam qualities (emittances) will be described in this report.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 2214-2219 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A high-power proportional temperature controller, using a fast infrared pyrometer, has been developed to change and control the temperature of metallic ribbon samples with microsecond response. The apparatus provides uniform and controlled heating for time-resolved x-ray scattering studies of structural phase transitions. When high-power pulse heating is used, the system is capable of increasing the sample temperature at rates in excess of 106 K/s, without overshoot and with subsequent control to ±1 K at temperatures as low as 650 K.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: High-energy photons and electrons on the Sandia National Laboratories "Z" accelerator, a z-pinch device, will deposit energy into a capsule and fuel; this may create a potential preheat problem for inertial confinement infusion (ICF). In this article we discuss heating of the capsule and fuel by high-energy photons and electrons. The fuel is heated to 〈2 eV, in a time-integrated sense, on Z by these particles. Because peak implosion occurs at the peak in the soft x-ray emission on Z, the heating at times of interest is reduced roughly an order of magnitude to ∼0.2 eV for times of interest and fuel preheat from this mechanism is concluded to be small. These estimates are generated from time-integrated bremsstrahlung measurements. The uncertainty in the heating is high because the electron spectrum is not known directly, but inferred. In addition, the influence of photons and electrons at energies between 5 and 60 keV is not known. Given the uncertainties at this point, we do not know the impact on the feasibility of internal dynamic hohlraums for a z-pinch-driven ICF implosion. We discuss these issues and suggest directions for further study. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 2438-2441 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A simple and economical method to determine the overall purity of inert gases such as Ar and He is described which uses the filament of commercial light bulbs. The lifetime of the incandescent filament is sensitive to gas impurities such as O2, H2O, and some hydrocarbons, but insensitive to N2 and, to first order, to the applied voltage. The relationship between the filament lifetime, τ, and the O2 and H2O concentrations was carefully calibrated. The relationship follows a power law: τ=AC−γ, where A and γ are positive constants depending on the impurity type. For mixtures of O2 and H2O, a simple superposition rule for the overall lifetime, τoverall, as 1/τoverall = 1/τO2 + 1/τH2O, applies. A mechanism for the concentration dependence of the filament lifetime is proposed in which the creep of the filament is enhanced by the impurity solutes in the filament. With a lifetime spanning from a few seconds to a few days, the filament acts as a simple gauge for the determination of impurity concentrations in an inert atmosphere. As an example, for O2, the measurable concentrations vary from 105 ppm to 10−2 ppm. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 64 (1993), S. 561-567 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A computer-automated superconductive 55 GHz sampling oscilloscope based on 4 kA/cm2, Nb/Nb2O5/Pb edge Josephson junctions is presented. The Josephson sampler chip was flip-chip bonded to a carrier chip with a coplanar transmission line by use of a novel flip-chip bonding machine. A 5.6 ps step pulse was successfully coupled in to the transmission line and 18.5 GHz multiple reflections plus a parasitic oscillation at 43 GHz were observed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗