ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • bioavailability  (27)
  • Lepidoptera  (23)
  • NDE  (21)
  • Triticum aestivum  (21)
  • Springer  (92)
  • 2015-2019
  • 1980-1984  (92)
Collection
Keywords
Publisher
  • Springer  (92)
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 17 (1980), S. 111-116 
    ISSN: 1432-1041
    Keywords: zimelidine ; norzimelidine ; antidepressants ; pharmacokinetics ; bioavailability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The systemic availability of a new antidepressant, zimelidine, and of its pharmacologically active metabolite, norzimelidine, was studied in six healthy male volunteers. Three single doses of zimelidine (25 mg and 100 mg orally and 25 mg i.v.) and two single doses of norzimelidine (25 mg orally and i. v.) were given to each volunteer allowing at least seven days between administrations. Plasma concentrations of zimelidine and norzimelidine were determined in serial blood samples by HPLC. Following oral zimelidine peak plasma concentrations of the metabolite were attained about 3 h after dosing. Oral administration of norzimelidine itself resulted in a plasma concentration profile for this compound that was similar to that observed after oral zimelidine. Utilising the plasma concentration data following intravenous infusion of each compound, the elimination half-lives for zimelidine and norzimelidine were calculated to be 5.1 h (range 4.3–6.0) and 15.5 h (range 10.6–22.9) respectively. The total body clearances of the 2 compounds were similar at 0.52 l · min−1 (range 0.26–0.70) for zimelidine and 0.56 l · min−1 (range 0.28–0.83) for norzimelidine. The substantially longer elimination half-life of norzimelidine was apparently the result of a larger volume of distribution (9.4 l · kg−1; range 7.8–11.4) for this metabolite, as compared to zimelidine (3.21 · kg−1; range 1.6–4.9). The calculated bioavailability of zimelidine was 26% (range 9.1–39) after the 25 mg oral dose, and 29% (range 14–46) after the 100 mg dose. The bioavailability of norzimelidine was 66% (range 36–91). However, oral administration of zimelidine resulted in as much or more norzimelidine reaching the systemic circulation, as the oral administration of norzimelidine itself. This is important as a large part of the activity of the drug may be due to the metabolite.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-5036
    Keywords: Lignin ; Manganese ; NO 3 − Phenols ; Triticum aestivum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Summary Managanese deficiency (〈 18 μg g−1 Mn) resulted in decreased levels of phenols in wheat shoots and decreased levels of lignins in both roots and shoots. These observed reductions in phenol contents was due largely to a decrease in the alkaline labile phenol component. Levels of nitrate supplied in solution influenced both phenol and lignin production; high nitrate levels (15 mM) resulted in a reduction in phenol and lignin in the shoot but stimulated lignin production in root tissue.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Entomologia experimentalis et applicata 30 (1981), S. 123-127 
    ISSN: 1570-7458
    Keywords: Sex Pheromones ; Repellent ; Heliothis armigera ; Heliothis zea ; Lepidoptera ; Noctuidae ; cotton bollworm ; corn earworm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Résumé L'examen en olfactomètre a porté sur les réactions face à d'autres femelles de la même espèce, de femelles vierges ou ayant copulé d'Heliothis armigera Hübner et H. zea Boddie. Le lot comprenait 8 femelles, vierges ou ayant copulé en présence d'une femelle vierge ou ayant copulé. Les 4 combinaisons possibles de femelles vierges et de femelles ayant copulé ont été examinées avec 12 répétitions pour chaque espèce. Un extrait de l'extrémité de l'abdomen de femelles vierges d'une espèce a été présenté aux femelles de l'autre espèce pour examiner les possibilités de réactions interspécifiques aux phéromones. Pour chaque espèce, les réactions interspécifiques de répulsion entre femelles ont été hautement significatives par rapport aux témoins, à l'exception toutefois des réactions de femelle ayant copulé face à des femelles ayant elles aussi copulé. Les répulsions moyennes chez H. armigera et H. zea pour les 8 femelles de chaque expérience ont été: a) vierges en présence d'une vierge: 7,33 et 7,66; b) vierges en présence d'une femelles ayant copulé: 5,76 et 5,58; c) femelles ayant copulé en présence d'une vierge: 4,67 et 4,83. Les différences sont hautement significatives entre chaque paire de moyennes et entre chaque paire et le lot témoin; 3,17; 3,17; 3,42; 4,00 pour H. armigera; 3,17; 3,50; 2,83 et 3,75 pour H. zea. Les femelles vierges des deux espèces, H. armigera et H. zea ont présenté une réaction de répulsion en présence d'un extrait de l'abdomen de l'autre espèce; les répulsions moyennes étant respectivement 5,53 et 5,33 contre 3,83 et 3,58 pour le lot trémoin. On peut en conclure que ces répulsions doivent entraîner une tendance à la répartition uniforme.
    Notes: Abstract An olfactometer was used to determine the effect of pheromones released by females of the bollworms Heliothis armigera (Hübner) and H. zea (Boddie) on females of the same species. Four combinations of virgin and mated females were tested for repellency of one to the other. Evidence is presented that females of the two bollworms were repelled by females of the same species. In addition, extracts of virgin female abdomens of each species repelled virgin females of the other species.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 19 (1981), S. 251-258 
    ISSN: 1432-1041
    Keywords: medigoxin ; digoxin ; dissolution rate ; proportionality ; bioavailability ; prediction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary We compared our ability to predict the dose of medigoxin and of digoxin required to achieve a fixed serum concentration (the dose requirement) in 33 outpatients. Preliminary work supported the assumptions that the steady state glycoside concentration achieved was proportional to the daily dose given to an individual, and that the bioavailability of the different tablet presentations was similar for either glycoside. We were not able to predict the dose requirement from patient characteristics with any more certainty for medigoxin than for digoxin. Not only the between-patient variability in dose requirement, but also the within-patient variability, was similar for the two glycosides. However the digoxin used had a dissolution rate of over 90% in 1 h. When comparing medigoxin with digoxin of lower, or more variable dissolution rate, medigoxin may be preferable.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1041
    Keywords: theophylline ; asthma ; children ; sustained-release ; diurnal ; absorption ; bioavailability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The absolute oral bioavailability of a sustained release theophylline tablet (Nuelin-SR250), given 12 hourly was determined in 14 asthmatic children aged 5 to 13 years. In 4 of the patients, mean bioavailability of the fourth dose was 38.9±8.4% and that of the sixth dose was 67.9±25.9% (p〈0.05) in the other ten patients. This suggests steady-state had not been achieved after four doses. In the initial study with 9 patients, a significant diurnal variation in predose plasma theophylline concentrations was observed, as the mean morning predose concentrations were 2.9 fold greater than the mean evening predose concentrations (p〈0.005). Dual peak plasma concentrations occurred in 5 out of the 9 patients. The mechanism of this diurnal variation was investigated in a further 5 asthmatic children (10.8 years ±1.6). Morning and night steady-state plasma theophylline concentrations during a continuous intravenous infusion of aminophylline were not different (14.9±5.3 mg/l vs. 15.6±5.9 mg/l), demonstrating that there was no diurnal variation in the plasma clearance of theophylline. The diurnal variation in predose concentrations with Neulin-SR250 was confirmed with the morning concentrations again being 2.6 fold greater than those in the evening. However, bioavailability was not significantly different for day (09.00–21.00) and night (21.00–09.00) dosing intervals after doses 6 and 7 respectively of Nuelin-SR250. The plasma concentration versus time profiles suggested that the diurnal variation in predose concentrations was due to slower absorption of the evening dose.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 3 (1982), S. 65-76 
    ISSN: 1573-4862
    Keywords: crack measurement ; ac field technique ; arbitrary skin depth ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A general solution is given to describe the ac field around surface-breaking cracks for arbitrary values of the ratio of skin depth δ to crack depthd. This solution allows accurate interpretation of crack depth from voltage readings taken by a Crack Microgauge instrument in cases where δ andd are comparable. It is shown to agree with asymptotic formulae obtained for the cases where δ/d is very small and very large. Provided that the probe length Δ is large compared with δ, the calculations show that a very good approximation to the crack depth may be obtained, irrespective of the ratio δ/d, by using the thin-skin asymptotic formula $$d = \frac{1}{2}\Delta (V_2 - V_1 )/V_1 $$ whereV 1 andV 2 are probe voltages registered at positions just off and across the crack, respectively. The problem is solved for a crack of infinite aspect ratio which has no opening, but it can be applied with confidence at the centerline of cracks of fairly large aspect ratio.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 4 (1984), S. 3-12 
    ISSN: 1573-4862
    Keywords: Ultrasonic ; stress measurements ; interfacial stress ; NiTi ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract In seeking to develop an NDE technique for verifying the serviceability of NiTi couplers for plumbing unions, it was found that the reflection coefficient for a normally incident ultrasonic wave correlated with the stress level at the NiTi-tubing interface. Current theory pertaining to interface reflection is not complete but, even at present status, there is semiquantitative accord between theoretical predictions and normalized data for reflection coefficient versus stress level. These results are at fixed frequency and with comparable surface roughness. Variation of either frequency or surface roughness further affects the reflection coefficient. Current studies are being pursued to define this effect.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 195-202 
    ISSN: 1573-4862
    Keywords: ac potential difference ; fatigue crack measurement ; slots ; artificial flaws ; parasitic voltages ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract The development of a successful and accurate instrument for measuring surface-breaking cracks in metals using the ac field technique has raised several interesting theoretical problems. Measurements with the instrument, known as the Crack Microgauge, do not rely on any prior calibration against an artificial flaw such as a saw-cut in a test block, but some users accustomed to such a calibration from other devices have nevertheless wished to use the instrument in that fashion and have in some instances reported erroneous results. In this paper, we develop a simple theory to explain and quantify this phenomenon. We calculate the parasitic voltages induced in the instrument probe due to the finite opening possessed by an artificial flaw, and we use these results to reinterpret the instrument readings. Controlled experimental measurements on artificial flaws of rectangular cross-section made in aluminum and in steel are found to be in good agreement with the theory. It is shown, however, that application of the theory requires additional information about the internal phase shift associated with the instrument. To enhance the accuracy of the theory, the effect of the corners of the artificial flaws was also considered, although it was not very influential in this work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1573-4862
    Keywords: stress fields ; microstructure ; J integral ; stress intensity factor ; harness acoustic velocity ; acoustic elasticity ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A very precise system for measuring two-dimensional velocity fields in solid samples has been used for nondestructive measurements of both externally applied and residual inhomogeneous stresses in solids,J integrals, stress intensity factors of cracks, and hardness of quenched steel. The longitudinal velocity measurement is based on precise determination of the propagation transit time through the stressed solid specimen using a small diameter, water-coupled acoutic transducer, which is scanned mechanically over the sample. Changes in velocity are then related to changes of stress in the sample by the theory of acoustoelasticity. Similar measurements show a high degree of correlation between longitudinal velocity changes and changes in microstructure in steel samples. Applications to problems of solid mechanics and material science illustrate the utility of this nondestructive measuring technique.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 65-74 
    ISSN: 1573-4862
    Keywords: NDE ; cast iron ; vibration analysis ; modulus ; strength
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract An outline is given of the existing nondestructive vibration tests for cast irons and their drawbacks in terms of the dimensional accuracy of the components. A proposal is made for a new test based on the change of resonant frequency with vibration amplitude exhibited by cast irons. This proposal is evaluated using material data obtained from dynamic tests of a wide range of cast iron specimens. A test rig is described suitable for testing cylindrical cast bars, and typical results are presented in relation to material strength. There is also a brief description of preliminary testing on cast products.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...