ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (107)
  • SPACE VEHICLES  (69)
  • Physics  (51)
  • ASTROPHYSICS
  • Animals
  • ENERGY PRODUCTION AND CONVERSION
  • 2015-2019
  • 1980-1984
  • 1970-1974  (228)
  • 1973  (228)
Collection
Keywords
Publisher
Years
  • 2015-2019
  • 1980-1984
  • 1970-1974  (228)
Year
  • 1
    Publication Date: 2019-07-13
    Description: A sensitive carbon monoxide detector, developed specifically for spacecraft use, is described. An instrument range of 0 to 60 ppm CO in air was devised. The fuel cell type detector is used as a highly sensitive electrolysis cell for electrochemically detecting gases. The concept of an electrochemical CO detector is discussed and the CO oxidation behavior in phosphoric and sulfuric acid electrolytes is reported.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-CR-120171
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 11 (1973), S. 1213-1224 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The synthetic details of solution polymerization in benzene and bulk polymerization of vinylferrocene are reported. In benzene solutions, with azobisisobutyronitrile (AIBN) as the initiator, small yields of low-polydispersity low molecular weight (M̄n ≃ 5000) polyvinylferrocene is obtained. However, high yields can be obtained by continuous or multiple AIBN addition. Higher molecular weight polymers and binodal polymers can be obtained as the monomer concentration is increased. In bulk polymerizations, yields of 80% can be obtained. The molecular weight increases as temperature decreases from 80 to 60°C in bulk polymerizations, and an increasing amount of insoluble polymer results. The soluble portion is often binodal, the higher molecular weight node consisting of an increasingly branched structure. Lower molecular weight polymer was readily fractionated into narrow fractions from benzene-methanol systems, but higher molecular weight polymer proved impossible to fractionate into narrow fractions due to branching.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 11 (1973), S. 807-811 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 11 (1973), S. 499-510 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The partial molar excess free enthalpies and enthalpies as well as the molar excess enthalpies of a number of n-alkane systems were reexamined within the scope of the polymer solution theory of Flory, Orwoll, and Vrij and that of Prigogine in the version after Delmas, Patterson, and Somcynsky. A semiempirical method was used to obtain characteristic n-alkane data, which obey the principle of corresponding states. By using these data (instead of those from the partition function after Flory and collaborators), a physically realistic interpretation of the excess free enthalpies over the whole concentration range is possible if the combinatorial contribution is purely athermal in nature. Both theories give an enthalpy interaction parameter near zero as expected, whereas neither a significant end effect nor an entropic interaction contribution is apparent from the analyses of the excess free enthalpies. The poor results obtained for the partial excess enthalpies and the enthalpies of mixing reflect the inadequacy of the partition functions on which these modern solution theories are based.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 11 (1973), S. 2451-2462 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Acrylonitrile (AN) was graft copolymerized onto gelatinized and granular wheat starch in aqueous media in the presence of ceric ammonium nitrate initiator at 91-364 anhydroglucose units (AGU) per cerium (IV) and at 1.08-4.33 AN to AGU ratios. Molecular weights and dispersities of polyacrylonitrile side chains were determined by gel-permeation chromatography. Conversion-time plots of AN polymerizations in both gelatinized and granular starch systems show characteristics common to heterogeneous polymerizations that could be explained on the basis of buried polymer radicals. The rates of polymerizations were directly related to the square root of the corrected cerium(IV) concentration and to the 1.3 power of the AN concentration. Graft copolymerization of AN onto starch, at least during initial stages, is not suitably explained by a kinetic scheme involving termination by polymer radical with cerium(IV) ion.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 11 (1973), S. 1683-1690 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Alkaline hydrolysis of model carbamates, polyurethanes, and poly(urethane-ureas) has been investigated. The model carbamates were based upon phenyl, benzyl, and cyclohexyl isocyanates. The polyurethanes and poly(urethane-ureas) were prepared from tolylene diisocyanate (TDI), xylylene diisocyanate (XDI), and 4,4′-dicyclohexylmethane diisocyanate (H12MDI) and a poly(oxyethylene)glycol of 6000 molecular weight. Pseudo-first-order rate constants of hydrolysis were obtained in aqueous pyridine solution at 110°C, and second-order rate constants were obtained in aqueous KOH solution for the model biscarbamates. Pseudo-first-order rate constants of hydrolysis were obtained in alcoholic KOH solution for the polyurethanes and poly(urethane-ureas). The hydrolysis of the model carbamates showed that the stability increased in the following manner: phenyl 〈 benzyl 〈 cyclohexyl. The pseudo-first-order rate constants were dependent upon the pKb of the corresponding amines. The hydrolysis of the polyurethanes and poly(urethane-ureas) showed that the stability increased in the following manner: aromatic 〈 aralkyl 〈 cycloaliphatic. It was shown that polyurethanes are more susceptible to alkaline hydrolysis than to acidic hydrolysis.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2006-03-28
    Description: A two-coordinate optical-mechanical scanning device (OMSD), the operating unit of which is a scanning disk, with directional and focusing optics and a board, on which the data carrier is placed, is examined. The disk and board are kinematically connected by a transmission mechanism, consisting of a worm and complex gear drive and a tightening screw-nut with correcting device, and it is run by a synchronous type motor. The dynamic errors in the system depend, first, on irregularities in rotation of the disk, fluctuations in its axis and vibrations of the table in the plane parallel to the plane of the disk. The basic sources of the fluctuations referred to above are residual disbalance of the rotor and other rotating masses, the periodic component of the driving torque of the synchronous motor, variability in the resistance, kinematic errors in the drive and other things. The fluctuations can be transmitted to the operating units through the kinematic link as a flexural-torsional system, as well as through vibrations of the housing of the device.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Cybernetic Diagnostics of Mech. Systems with Vibro-acoustic Phenomena (NASA-TT-F-14899); p 301-305
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2006-03-27
    Description: On Mars, the Mariner observations show a twenty-fold variation in the amount of ozone, depending on the presence or absence of another minor constituent, water vapor, in the atmosphere. In the evolution of earth's primitive atmosphere, the formation of an ozone layer may have played an important role in the prebiotic chemistry that took place on the surface. The seasonal formation and disappearance of ozone in the contemporary Martian atmosphere may be of consequence in any prebiotic chemistry that may be occurring there.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: JPL Mariner Mars 1971 Proj., Vol. 4; p 369-372
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2011-08-16
    Description: We have developed a Fourier-transform infrared spectrometer having a resolution of 0.5/cm over the range of wavelength from 1 to 5.5 microns. It has been used to observe the sun over this wavelength range from a Lear Jet flying at an altitude of 14 km, and to observe a number of stars from the ground, using the 229-cm telescope of the Steward Observatory and the 152-cm aluminum-mirror telescope at the Observatorio Astronomico Nacional in the Sierra de San Pedro Martir, Baja California, Mexico. The solar spectrum is given here, while the ground-based spectra are being published separately.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Astronomical Society of the Pacific; vol. 85
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2011-08-16
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 12; Apr. 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...