ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (798)
  • Cell & Developmental Biology  (277)
  • EARTH RESOURCES AND REMOTE SENSING  (228)
  • FLUID MECHANICS AND HEAT TRANSFER  (215)
  • SOLAR PHYSICS  (144)
  • Inorganic Chemistry  (138)
  • METEOROLOGY AND CLIMATOLOGY  (132)
  • 1985-1989  (1,251)
  • 1980-1984  (657)
  • 1925-1929  (24)
  • 1988  (619)
  • 1987  (632)
  • 1982  (657)
  • 1926  (24)
Collection
Keywords
Publisher
Years
  • 1985-1989  (1,251)
  • 1980-1984  (657)
  • 1925-1929  (24)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 26 (1988), S. 1271-1286 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Random copolymers of ethylene with 1-butene, 1-octene, and 1-octadecene have been prepared using a homogeneous vanadium-based catalyst system. Comonomer contents determined by 13C-NMR analysis of polymer solutions are in the range 1-10 mol%. Crystallinities were estimated by means of density measurements, x-ray diffraction, differential scanning calorimetry, laser Raman spectroscopy, and CPMAS 13C-NMR spectroscopy. The results are compared with those obtained for heterogeneous copolymers of ethylene containing 1-4 mol% 1-butene. As the comonomer content is increased, the crystallinity decreases. The dimension perpendicular to the 110 plane in orthorhombic crystallites decreases linearly with crystallinity. This decrease in crystallite size is accompanied by an increase in the size of the orthorhombic unit cell. For copolymers containing large amounts of 1-octene and 1-octadecene, a second crystalline form appears. Differences in estimates of crystallinity are discussed in terms of looser packing in highly branched copolymers and the extent to which the second crystalline form participates in the phase structure.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 35 (1988), S. 1803-1815 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Thermal properties like glass transition temperature (Tg), initial decomposition temperature (idt), integral procedural decomposition temperature (ipdt), and temperature at various % weight loss of a number of polyurethane systems are reported in this paper. Glass transition temperature was determined on TMA, and other thermal properties were determined by thermogravimetry. The experiments were designed to understand various factors such as length of chain extender moiety, flexibility of chain extender units by substitution of ether link in the diol chain, nature of bonds (unsaturation) in the extender unit, and nature of diisocyanates.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0887-6258
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 25 (1987), S. 2063-2075 
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Divalent organochromium compounds, Cr(Lig)2, often become active catalysts for the polymerization of ethylene when deposited onto an oxide carrier such as silica or aluminophosphate. Hydroxyl groups are thought to react, releasing one ligand and binding the chromium to the surface. The behavior of the catalyst is then governed by the remaining ligand and the type of carrier. In this study two types of ligands were investigated: cyclopentadienyl and its open ring analog dimethylpentadienyl. This small difference in the type of ligand produces a fundamental difference in the polymerization mechanism. For comparison the mixed ligand chromocene, with one open and one closed ligand, was also synthesized and tested for polymerization.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 21 (1987), S. 683-700 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study examines the interaction of human low density lipoprotein (LDL) with a select group of biomedical polymers. The adsorption characteristics of LDL on cured filler-free poly(dimethyl Siloxane) (C-PDMS), Biomer, Cardiomat 610, Kraton 1650, poly(hydroxyethyl methacrylate) (PHEMA) and glass are presented. Adsorption of LDL to charged hydrophilic glass control surfaces occurred rapidly, reaching plateau concentrations within one minute (0.19 ± 0.01 ug/cm2). Adsorption of LDL to polymer surfaces appeared to be dependent upon both the polymer hydrophobicity (or apolar nature), and flexibility (or dynamic nature) at the interface. Increased surface concentrations were observed for Biomer (0.32 ± 0.01 ug/cm2) as well as other polymers which exhibited both hydrophobic and elastomeric próperties. Temperature changes between 25°C and 37°C were found to significantly influence the surface concentration of LDL on Biomer (0.16 ± 0.01 ug/cm2 at 25°C versus 0.32 ± 0.01 ug/cm2 at 37°C). A lipid core phase transition at 36°C was believed to be responsible for the temperature influence. Preliminary competitive adsorption studies of LDL with albumin (HSA) and serum on silicone surfaces suggests that LDL adsorption occurred rapidly and preferentially (0.25 ± 0.01 ug/cm2 for LDL alone; 0.33 ± 0.01 ug/cm2 for LDL + HSA; 0.15 ± 0.01 ug/cm2 LDL + serum). Preliminary studies on the role of LDL in calcification were not conclusive. It can be concluded that LDL adsorption is dependent upon polymer hydrophobicity, flexibility and temperature. Competitive adsorption experiments suggests that LDL may have substantial influence on protein adsorption.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 381-398 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Numerous hypotheses exist to explain observed blood-materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer-coated tubes; centrifugal force platelet adhesion on polymer-coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer-coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood-materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypotheses can explain the apparent conflict between the platelet adhesion data and the coagulation time data.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Cellular Physiology 112 (1982), S. 10-18 
    ISSN: 0021-9541
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Intermediate subviral particles (ISVP) derived from reovirus represent a simple model system for the switch-on of transcriptase function. In such particles the endogenous transcriptase is present in a switched-off form, one step removed from the switched-on state. Switch-on of transcriptase function is an active process in this system and can be triggered by K+ ions. A variety of agents which affect gene expression in cells were tested for an effect on switch-on in ISVP. Marked effects on switch-on in ISVP were observed with a diverse group of test agents, including DMSO and other solvents, BUdR, TdR, caffeine, theophylline, and temperature. The correlation in response between ISVP and cells suggests that the ISVP system may be useful as a model for studying the biochemical mechanisms underlying the perturbative effects of such agents on gene expression in cells.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 10 (1987), S. 338-342 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Multi-element (52Cr, 56Fe and 66Zn) implanted GaAs samples have been prepared specially for SIMS calibration. Absolute chemical measurements gave retained ion doses which agreed to within 12% of the nominal implanted dose (2.0 × 1014 atoms cm-2). Comparative SIMS depth profiles with five instruments gave Cr mode depth data which showed a variability of 5%. After data normalization to a common mode depth (168 nm) the shape of all profiles showed good agreement. SIMS anàlysis of similar samples containing lower dose implants (1.0 × 1013 atoms cm-2) showed that ∼50% of the Cr was contained in the near surface region (0-0.03 μm). This surface peak was not observed in profiles of samples which had been singly implanted with Cr. It is proposed that the Cr surface peak results from radiation enhanced out-diffusion initiated by the subsequent Fe implant. Whilst the high dose multi-implant samples showed a similar Cr surface accumulation, its magnitude in relation to the ion implanted dose, was smaller. These samples therefore form reliable calibration specimens for the simultaneous determination of the secondary ion responses of Cr, Fe and Zn in GaAs.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2011-08-19
    Keywords: FLUID MECHANICS AND HEAT TRANSFER
    Type: Journal of Propulsion and Power (ISSN 0748-4658); 3; 219-226
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2017-10-02
    Description: Unsteady two- and three-dimensional flow structure at leading and trailing edges of bodies can be characterized effectively using recently developed techniques for acquisition and interpretation of flow visualization. The techniques addressed here include: flow image/surface pressure correlations; 3-D reconstruction of flow structure from flow images; and interactive interpretation of flow images with theoretical simulations. These techniques can be employed in conjunction with: visual correlation and ensemble-averaging, both within a given image and between images; recognition of patterns from images; and estimates of velocity eigenfunctions from images.
    Keywords: FLUID MECHANICS AND HEAT TRANSFER
    Type: AGARD, Aerodynamic and Related Hydrodynamic Studies Using Water Facilities; 13 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...