ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (344)
  • Springer  (344)
  • American Association for the Advancement of Science (AAAS)
  • Elsevier
  • 1995-1999  (344)
Collection
Keywords
Publisher
  • Springer  (344)
  • American Association for the Advancement of Science (AAAS)
  • Elsevier
  • Wiley-Blackwell  (1)
Years
Year
  • 11
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral resolution of amino acids ; Pre-column derivatization ; Fluorescent chiral tagging reagents ; Stereochemical purity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Derivatization of amino acid enantiomers with fluorescent chiral Edman-type reagents, 4-(3-isothiocyanatopyrrolidin-1-yl)-7-nitro-2,1,3-benzoxadiazole [R(−)- and S(+)-NBD-PyNCS] and 4-(3-isothiocyanatopyrrolidin-1-yl)-7-(N,N-dimethylaminosulfonyl)-2,1,3-benzoxadiazole [R(−)-and S(+)-DBD-PyNCS], yields corresponding diastereomers separable by reversed-phase HPLC on normal achiral columns. The resolved diastereomers were detected fluorometrically at 530 nm with excitation at 490 nm for the NBD-PyNCS derivatives and at 560 nm with excitation at 450 nm for those derived from DBD-PyNCS reagents. This HPLC-derivatization method was used for evaluation of stereochemical purity for some synthetic commercial peptides. The enantioanalysis was reliable down to 0.05% racemization of the amino acid residues and a quantity of 100 μg peptide sample was usually enough for the analysis. Two acid hydrolysis methods, i.e. the standard procedure with constant-boiling hydrochloric acid (HCl) and a rapid vapor-phase procedure with HCl-trifluoroacetic acid (TFA) mixture, were compared. The later was found to be unsuitable owing to increased racemization of the amino acid residues during the hydrolysis. Judging from the results obtained for proline and leucine residues, most of the tested peptides including biologically active peptides, such as neurotensin, [d-Ala2,d-Leu5]-enkepharin and morphine tolerance peptide, possessed stereochemical purities higher than 98%. Influence of structural features of the peptides on the racemization of the amino acid residues was found to be significant.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Mass spectrometric detection ; Fast atom bombardment ionization ; Serum bile acid ; Rat bile
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In order to analyse bile acids in biological matrices, e.g. rat bile and human serum, high performance liquid chromatography (HPLC) was coupled to continuous-flow fast atom bombardment mass spectrometry (CFFAB-MS). A gradient elution system which had already proved to be well suited for the quantitative determination of conjugated bile acids in bile was modified to allow HPLC-CFFAB-MS-coupling. Due to the sensitivity of this coupling method it is possible to obtain more information about the biliary bile acid pattern and species-specific secondary bile acids. Furthermore, we were able to identify obviously unknown bile acid species in rat bile which most likely classify as mono-oxo and di-oxo-taurocholates (MW 513 Da, 511 Da) and mono-oxo-glycocholates (MW 463 Da). In the present study we show that using this system it is possible to determine both conjugated and unconjugated as well as sulfated bile acids, without time consuming group separation and derivatization, from rat bile and human serum. In addition, it is suggested that the method presented here should be considered for use in routine analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Fluorescence enhancement ; Bovine serum albumin ; Dansylamino acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The effects of acetonitrile and bovine serum albumin (BSA) concentrations on the signal intensity and retention behavior of dansylamino acids have been examined by using γ-cyclodextrin-bonded silica gel as the stationary phase in microcolumn liquid chromatography. Fluorescence intensities of dansylamino acids were enhanced by BSA as a mobile phase additive, e.g., detection limits of dansyl derivatives of L-Ala and L-Phe were improved by a factor of 12–18.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Micellar liquid phases ; Octanol-water partition coefficient ; Benzene and naphthalene derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary It is shown that the logarithm of the capacity factor (log k′) for fifteen benzene and naphthalene derivatives in micellar liquid chromatography with forty nine different mobile phases generally correlates better with the logarithm of the octanol-water partition coefficient (log Pow) than the capacity factor (k′). Optimum conditions are established to obtain the best linear correlations of log k′-log Pow.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Photolysis ; Electrochemical detection ; Drugs with chlorinated aromatic rings
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Pharmaceuticals containing a thiazide ring or chlorinated aromatic ring were investigated with respect to enhanced selectivity in determination. Oxidative electrochemical detection coupled with HPLC was used to study the influence of the pH of the mobile phase under conditions of photolysis. To cover a pH range 3.9–12, the employment of a polymer column stable in alkaline media was necessary. The method offers the great advantage of derivatization without chemicals at low operating potentials, thereby providing high selectivity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 296-302 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Structural isomer separation ; Cyclodextrin ; Polymers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Several β-cyclodextrin (CD)-bonded stationary phases for high performance liquid chromatography (HPLC) were prepared, based on silica beads coated with a poly(alkylamine), [poly(ethyleneimine)(PEI)]. In order to obtain stationary phases with a high content of CD and maximum accessibility of the CD cavity, the functionalization was carried out after the coating, using the mono-tosyl derivative of CD as the intermediate. The ability of these supports to separate ortho, meta and para isomers of some disubstituted benzene derivatives was examined. The contribution of the amino groups of the polymer and of the CD cavity to the separation process is discussed. The resolution is mainly based on the difference in the stability of the complexes of the various isomers with CD. The influence of the amount of CD on the height of the theoretical plate is also studied.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed phase ; Polystyrene ; Pellicular ; Ultra high molecular mass
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Ultra high molecular mass (〉 7 million dalton) polystyrenes are prone to degradation in size exclusion chromatography. In gradient elution reversed phase HPLC they do not elute visibly on small particle size porous supports. However, large diameter C18 pellicular particles were successfully employed for reversed phase study of ultra high molecular mass (15 million dalton) polystyrenes without polymer degradation during elution. Although retention for the lower molecular mass polystyrenes was lower than on small diameter porous particles, the medium high molecular mass polystyrenes (0.5–1 million dalton) showed similar retention. The addition of small diameter porous particles in small quantities, to the large diameter pellicular particles, increased the amount of retention of the low molecular mass polystyrenes without affecting the higher molecular mass polystyrenes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Methyl ethyl ketone in urine ; Derivatization ; 3-Methyl-2-benzothiazolinone hydrazone ; Comparison with GC-MS
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A HPLC method for the determination of methyl ethyl ketone (MEK) in urine after derivatization with 3-methyl-2-benzothiazolinone hydrazone is proposed. The calibration curve for the ketone was linear, ranging between 0.23–10 mg/L, with a detection limit of 0.025 mg/L. The results were compared to those obtained by GC-MS, coupled to the headspace technique. MEK derivatization and the derivative purification processes were verified with respect to the main variables such as reaction temperature, reagent concentration, probable interferences and enrichment phase. The method is simple and reliable and shows a good sensitivity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 382-386 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Sulfonamides in foodstuffs ; Honey ; Milk ; Eggs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure for the simultaneous determination of several sulfonamides in different foods, such as honey, milk and eggs is proposed. The analysis is carried out using reversed phase liquid chromatography with spectrophotometric detection. Optimization of the mobile phase led to good separation and a short analysis time when an initial isocratic step with a 3∶97 acetonitrile: water mixture was used for 5 minutes, followed by a linear gradient up to a 40∶60 mixture over 15 min. The proposed method is suitable for routine quality control analysis to ensure the absence of sulfonamides in foods. Recovery studies yielded good results for all food samples because there were no interferences from the matrices.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 411-416 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Particle beam LC/MS interface ; Capillary columns for LC ; Mycotoxins ; Peanut meal
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new method for the analysis of aflatoxins in food extracts, based on liquid chromatography/mass spectrometry interfacing, is presented. The chromatographic separation was performed with a reversed phase packed capillary column coupled with a modified particle beam interface capable of handling microliter per minute flow rates. This system allows higher overall sensitivity and easier operation procedures. The method has proved to be particularly suitable for the analysis of the toxins in very complex matrices. The specificity of electron impact ionization allowed positive identification of the aflatoxins with an excellent response linearity for accurate quantitation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...