Summary: This report presents numerical results on the feasibility study of the use of in-ice cooling for a power plant. As a result of this type of arrangement, a water pond under ice is formed. The pond size as a function of time for various operating conditions has been computed. The associated problems such as water temperature, power consumption, etc., are also studied.
Type of Medium:
Series available for loan
Pages:
iv, 17, A6 Seiten
,
Illustrationen
Series Statement:
Research report / Cold Regions Research and Engineering Laboratory 60
URL:
https://hdl.handle.net/11681/2751
Language:
English
Note:
CONTENTS
Preface
Summary
Introduction
Open-loop system
Method of analysis
Time dependence of pond size
Temperature of water in the pond
Effect of inlet water temperature
Effect of convection duct
Power consumption for circulation of cooling water
Condlusions
Closed-loop system
Method of analysis
Time dependence of pond size
Flow conditions of glycol solutions inside coil
Discussion and conclusions
References
Appendix: Examples of calculations