ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (771)
  • Wiley-Blackwell  (771)
  • Annual Reviews
  • 2005-2009
  • 1990-1994  (771)
  • 1980-1984
  • 1993  (771)
  • Technology  (643)
  • Architecture, Civil Engineering, Surveying  (128)
Collection
  • Articles  (771)
Years
  • 2005-2009
  • 1990-1994  (771)
  • 1980-1984
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 279-279 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993) 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 289-301 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The „tail string“ that extends from a contraceptive intrauterine device (IUD) into the vagina is an illustrative case in materials engineering design. The strings must satisfy certain criteria for strength and other properties in order to fulfill the function of providing a means of insuring that the IUD has not been ejected, and eventually of helping remove the IUD. This must be done without contributing to an additional risk of unwanted medical side effects beyond those that may be inherent in any such device. Oriented monofilament olefins appear to satisfy these criteria, and have been used successfully in several IUD designs. This article describes a study of two such monofilaments taken from new IUDs, showing how the material's processing, structure, and properties lead to effective performance as tail strings. Several types of used IUDs were also studied, to insure that nothing occurred during use that would alter the conclusions drawn from the study of new strings. © 1993 John Wiley & Sons, Inc.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: There is growing concern in the medical community that silicones, ubiquitous in health care, may exhibit antigenic, immunogenic, and/or adjuvant activity. Sera from women with silicone breast prostheses were assayed by ELISA for humoral immunoreactivity to a variety of common interstitial and cellular components. In decreasing order of frequency, significant IgG avidities were found against silicone surfaces treated with fibronectin-laminin, phospholipids, no treatment, and fibrinogen when compared with sera obtained from healthy, age-matched, nonimplanted women and a population of nonimplanted women with previously diagnosed autoimmune diseases. Moreover, the sera from approximately 15% of the positive responders were found to react to matrix proteins independent of the siloxane polymer. The data show human antibody production to native macromolecules with antibody avidity being related to molecular conformation. Silicone may function as an adjuvant by inducing changes in the conformation of native molecules. © 1993 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 47-54 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The static general corrosion behavior of Ti-6Al-4V alloy specimens in three lactated Ringer's-based solutions was investigated using d.c. potentiodynamic, d.c. linear polarization resistance, and a.c. impedance techniques. A critical appraisal of the use of these techniques for the estimation of the corrosion rate of the material is presented. Whence it was shown that the presence of bovine serum in or decreasing the pH level of (to about 1) lactated Ringer's solution leads to an increase in the corrosion rate of the alloy (relative to that in lactated Ringer's solution, pH 6.25). © 1993 John Wiley ' Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 55-60 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Ferromagnetic Ni—Cu alloy wires were characterized in order to obtain well-defined thermoseeds for application in interstitial hyperthermia of prostate cancer. Thermoseeds have been produced which possess Curie points in the therapeutic hyperthermia range, approximately 40 to 50 °C. The effect of thermal treatment and composition on the heating characteristics of the thermoseeds were investigated. The preliminary study shows that the recrystallization is crucial for altering thermoseeds' heating characteristics. Obtaining thermoseeds which behave as desired depends on changes in annealing times and temperatures. One may increase the maximum heating temperature (similar to Curie temperature) by increasing the annealing time and cooling time. Decreasing the lower annealing plateau temperature also increases the maximum seed heating temperature. Higher nickel content compositions did not affect rise time but increased the maximum heating temperature. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 61-65 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The establish criteria for characterizing synthetic sutures, the handling characteristics of silk suture were analyzed. The characteristics that distinguish silk suture from other braided suture materials are its good “knot security” and relatively low “tiedown resistance.” Analytic consideration of knot security suggests that not only superficial friction but also resistance force produced by cross-sectional deformity of braided threads plays an important role in silk's superior performance. Results of a “pullout friction test,” developed to quantitatively evaluate resistance produced by surface friction and cross-sectional deformity suggest that the superiority of silk thread can be explained in terms of high static withdrawal resistance under low loads and relatively low dynamic withdrawal resistance under high loads. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 73-75 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: There has been an increase in the use of primary reference material as a standard for identifying the cellular response to biomaterials. One such material is NHLBI-DTB polydimethylsiloxane (PDMS). The PDMS was developed for blood contacting studies and is composed of PDMS backed on one side with mylar. The results of implantation studies of two different publications are discussed in light of the different materials and different surface topographies of each of the materials. The appropriateness of in vivo studies using this reference material is questioned. © 1993 John Wiley & Sons, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 77-85 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Stents are tubular devices that are used in cylindrical passages of the body following trauma or disease in order to keep the cross section of these passages open. A mathematical model of a self-expanding metallic stent has been developed with the aim of predicting various geometrical and mechanical properties of the stent. The model was developed with the main assumptions that the stent acts as a combination of a number of independent open-coiled helical springs with ends fixed against rotation, and that the springs undergo elastic deformations only. A series of experiments has been carried out in order to assess the validity of the model. The experimental results show good agreement with theory for the tests involving stent diameter and longitudinal force as a function of stent length and fair agreement, limited by frictional effects, for the tests involving radial pressure as a function of stent diameter. © 1993 John Wiley & Sons, Inc.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 67-72 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Fibroblast growth factor (FGF) is a polypeptide that has been shown to have a stimulatory effect on osseous tissues in vitro. This study characterized the release of FGF from plaster of Paris (PLP) and measured the dissolution of PLP in various solutions with the aim of developing a reliable carrier system for the release of FGF in vivo. The study consisted of five experiments: (I) FGF diffusion from PLP pellets, (II) FGF diffusion from PLP discs, (III) PLP dissolution in saline, (IV) PLP dissolution in serum, and (V) FGF adsorption by commercially pure titanium. FGF was observed to be released at a rate directly proportional to the rate of dissolution of the PLP carrier, suggesting that either the FGF binds to the PLP; or, alternatively, the FGF may be entrapped by the PLP. Dissolution rate, and thus release rate, could be varied by varying the mass of the carrier. Greater diffusion of FGF was observed in larger, more slowly dissolving PLP carriers. Dissolution of PLP was observed to be slower in serum than in saline, apparently due to stabilization by factors in the serum but not due to a concentration gradient effect. Titanium coupons did not adsorb significant amounts of FGF. These results indicate that PLP, which has been shown in the past neither to FGF. These results indicate that PLP, which has been shown in the past neither to aggravate inflammatory response nor to interfere with bone ingrowth, may serve as delivery vehicle for FGF to osseous tissues in vivo. © 1993 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 103-105 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 7 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Two new cardiovascular monofilament sutures attached to taper point needles have been developed for use in expanded polytetrafluoroethylene (PTFE) grafts. One monofilament suture made of PTFE has a microporous structure that allows it to be channel swaged to a needle that closely approximates its suture diameter. The other suture is a monofilament polypropylene suture that has been extruded to produce a tapered swage end, which was significantly smaller than that of the remainder of the suture in order to be channel swaged to smaller diameter needles. On the basis of comprehensive biomechanical performances, the performance of the new needle suture products with needle/suture diameter ratios approaching 1:1 was superior to needle suture products with 2:1 needle/suture diameter ratios for use in PTFE vascular grafts, regardless of the suture material. © 1993 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 115-115 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993) 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 119-125 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Ultra high molecular weight polyethylene (UHMWPE) wear particles are frequently implicated in causing failure of total joint arthroplasties by eliciting a foreign body reaction. The majority of these particles are subcellular and many are submicron in size. Identification of these small particles of UHMWPE by conventional histologic techniques is difficult. We have therefore investigated the utility of Oil Red O (ORO) stain to identify UHMWPE on histologic sections.A wide variety of specimens was studied including an experimental rabbit model with subcutaneous implantation of polyethylene particles as well as specimens from clinical cases with joint arthroplasties. The sensitivity and specificity of ORO stain was compared to conventional polarized light microscopy for the identification of particulate UHMWPE debris. The ORO stain was found to be as sensitive in identifying particulate UHMWPE debris as polarized light microscopy. However, ORO stain was less specific: two specimens that did not contain any UHMWPE also stained with ORO. Careful examination of standard hematoxylin and eosin stained sections with polarized light was therefore more specific for the identification of particulate UHMWPE. As a single test, the ORO stain does not appear to offer any clear advantage specifically for the identification of UHMWPE. © 1993 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 127-134 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The effect of pulsed electromagnetic fields (PEMFs) on the foreign body response to particulate debris, similar in morphology and quantity to wear debris present in the tissues around loose total joint prostheses, was investigated using a rabbit model. Cobalt chrome pins were inserted into the femurs along with particulate debris consisting of ultra high molecular weight polyethylene (UHMWPE), polymethylmethacrylate (PMMA), and cobalt chrome (CC). The particles induced a significant cellular response compared to the control animals that did not receive any debris. The application of PEMFs did not increase this foreign body response, nor did it have an effect on the number of resorption cavities, cortical area, or cortical thickness. © 1993 John Wiley & Sons, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 135-141 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We have developed a bioactive bone cement consisting of silane-treated CaO—SiO2—P2O5—CaF2 glass powder as the filling particles and bisphenol-a-glycidyl methacrylate (BIS-GMA) diluted with triethylene-glycol dimethacrylate (TEGDMA) as the organic matrix. Histological examination demonstrated direct bonding between the cement and bone along the circumference of the cement at 4 weeks after implantation in rat tibia. The compressive strength and toughness of the cement were two and four times greater than those of polymethylmethacrylate (PMMA) cement, respectively. The inflammatory reaction of the skin caused by the new cement was not as intense as that for PMMA 3 days after subcutaneous implantation. This new cement may be applicable as a bioactive bone cement with high mechanical strength. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 157-160 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Needle performance is primarily judged by its penetration through tissue. For detailed studies of needle performance, tissue is too heterogeneous and unstable and difficult to obtain. A homogeneous, stable, and readily available polyurethane substrate has been evaluated as a suitable alternative to biological tissue for evaluation of needle penetration. The needle penetration profiles through the synthetic substrate correlated very well with those through natural tissue. In addition, the synthetic substrate was sensitive enough to easily detect a 20% increase in the force necessary to penetrate natural tissue. This polyurethane substrate offers a valid alternative to biological tissue for the testing of needle penetration performance. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 213-219 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to investigate the bone response to three different types of titanium (Ti) alloys and hydroxyapatite (HA) coated titanium alloy by histological and histomorphometrical analysis. Therefore, implants made of these materials were inserted into the tibia of rabbits. Implantation times were 6 and 16 weeks. The histological evaluation included measurement of the amount of bone apposition and analysis of the bone reaction and interface characteristics around the implants. The results demonstrated no marked differences in bony reaction to the different implant materials. In addition, the HA coatings showed loss of thickness. © 1993 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 231-240 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Because of the importance of complement activation in the induced activation of leukocytes in vivo, determination of complement-activating capacity of a candidate biomaterial is an important step in evaluating its biocompatibility. In vitro evaluation can be performed in the presence of human serum by means of techniques described in the literature and reviewed in this paper. Certain physical and chemical parameters involved in complement activation by materials have to be assessed: the chemical composition of the surface, surface area in contact with serum, temperature and duration of contact, and ionic environment with emphasis on divalent ions. Concerning materials evaluation, the adsorption of complement proteins or protein fragments has to be determined in addition to activation. Following screening tests using CH50 determination, activation of both classical and alternative pathways leading to formation of C3 convertases and formation of C5 convertase should be assessed. An example of the determination of the complement-activating capacity of two hydroxylated materials is presented and guidelines for in vitro evaluation are proposed. © 1993 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 241-247 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The purpose of this study was to determine the influence of the surgeon's tying techique on knot security using 0 and 2-0 monofilament and multifilament nylon sutures. Using an Instron® Tensile Tester and a portable tensiometer, knot security was achieved with these sutures using four-throw square knots (1=1=1=1). After didactic and psychomotor skill training, medical students were taught to construct the four-throw square knot using either a two-hand tie or an instrument tie. Using the portable tensionmeter, their knot tying techniques were judged to be superior to those used by surgeons. The surgeon's faulty technique can easily be corrected by didactic information and psychomotor skill training. © 1993 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Hydroxyapatite induction by a synthesized pure silica hydrogel was examined in various simulated body fluids (SBFs) having different magnesium, calcium, and phosphate ion concentrations as well as pH values. The silica hydrogel generated biologically active apatite on its surface by taking up calcium and phosphorous ionic groups from a surrounding SBF that was prepared to emulate the human plasma in inorganic composition. The induction period for apatite nucleation on the surface of the silica was largely decreased with the addition of a small amount of the calcium or phosphate ions to the SBF and with an increase in pH, but increased with the addition of magnesium ion. Bioactivity of bioactive materials like Bioglass® and glass-ceramic A-W was well interpreted in terms of the rate of apatite formation reflected in these results. Moreover, the results provide the basic knowledge for designing new bioactive materials. © 1993 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 249-252 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An in vitro evaluation was conducted of the adhesion capabilities of rabbit corneal endothelial cells on intraocular lenses (IOLs) made of heparin-coated polymethylmethacrylate (HSM-PMMA). The concave endothelial surfaces of albino rabbit corneas were placed in contact in vitro with the convex surfaces of the optical side of HSM-PMMA IOLs in 4-day cultures. PMMA IOLs served as controls. After an incubation period, the preparations were examined via phase-contrast microscopy and via inverted microscopy after staining with vital dye (neutral red), both with and without the cornea in place. After fixation and staining with Giemsa, the cells adherent on the lens were counted on five different microscopic fields. It was observed that the corneal endothelial cells adhered equally to heparin-coated and untreated PMMA IOLs. © 1993 John Wiley & Sons, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 269-272 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 277-277 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 317-329 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Apatite-wollastonite-containing glass-ceramic (A - W · GC) has a strong ability to bond to bone and relatively high mechanical strength. Therefore, as a bulk material it has recently been applied clinically even in load-bearing sites. In this study, we modified A-W · GC by altering its composition ratio with the removal of CaF2 and the addition of B2O3, and examined the potential use of the resulting new glass-ceramic as a material for coating on a titanium (Ti) alloy. The bioactivity of this new coating (NC) material and its bonding ability to bone were investigated mechanically and histologically. After implantation of the Ti alloy plate coated with this material into the tibiae of rabbits for 2, 3, 4, 8, and 25 weeks, a detaching test was performed. The detaching failure load of the NC plates was compared with those of A-W · GC plates, hydroxyapatite (HA) plates, and uncoated Ti alloy plates implanted in the same way. The failure load of NC was as high as that of A-W · GC for all periods, whereas it was significantly higher at 3 and 4 weeks than that of HA. Uncoated Ti alloy showed lower failure loads for all periods, differing significantly from the other materials. There was no breakage or detachment of the coating layer observed after the detaching test. Histological examinations by CMR, Giemsa surface staining, and SEM-EPMA showed that NC bonded directly to bone without any intervening soft tissue layer. A calcium-phosphorus-rich layer (apatite layer) was observed within the coating layer, as is the case in A-W · GC. These results indicate that this new glass-ceramic has earlier bone-bonding ability and high mechanical strength, making it a promising coating material. © 1993 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 341-346 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A testing method was developed to evaluate the mechanical properties of a fibrin adhesive in an effort to correlate mechanical strength to fibrinogen content. Autologous fibrin adhesives with varying fibrinogen content were loaded to failure in shear using a mechanical testing machine. The method developed was capable of distinguishing a mechanical strength difference among the three fibrin sample lots used in the study. A number of parameters were evident that could lead to testing variability. The development of a more sophisticated component delivery system would greatly reduce the variability of these parameters and thus, the product reliability. Ultimately, the information gathered from the current and future studies will form a type of quality control standard to directly correlate the percentage of fibrinogen in a particular sample to its adhesive performance. © 1993 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 109-111 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 107-107 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 113-113 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Polyurethane films that contained various amounts of zinc diethyldithiocarbamate (ZDEC) and zinc dibutyldithiocarbamate (ZDBC) were prepared as standard reference materials (SRM). Using three cell lines of V79, L929, and Balb/3T3 cells, the cytotoxicity of the dithiocarbamates and the SRM films were compared by agar diffusion assay, filter diffusion assay, neutral red assay, cell growth assay, and colony assay. Among these in vitro cytotoxicity tests, colony assay was found to be the most sensitive method for detecting the cytotoxicity. The cytotoxic potentials of extracts from SRM films correlated well with the concentrations of ZDEC or ZDBC involved in SRM. When various rubber materials including SRM and surgical rubber latex materials were tested, cytotoxic potentials of these extracts were also correlated with the inflammatory tissue capsule thickness in short-term implantation tests. On the basis of these results, the SRM is judged to be useful for validating test sensitivity, and comparing the correlation between in vitro and in vivo responses. © 1993 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 161-167 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Four stainless steel alloys, commonly used for surgical needles were tensile and bend tested. The materials included: ASTM 42000, ASTM 45500, ASTM 30200, and a Fe-12Cr-8.5Ni-3.2Mo-1.9Ti alloy. Small diameter wires in a wide range of strength levels were produced using various heat treatments and/or cold drawing. Samples from each processing condition were tensile and bend tested. Calculated yield moment and ultimate moment were determined using tensile yield strength, the flexural formula (M(y) = σ(y) I/C), and the shape factor for circular cross sections (M(u)/M(y) = 1.7). A deviation was observed between the theoretically calculated yield moment and a 2° offset measured yield moment. This was expected because moment-strain diagrams provide only an approximation of yield moment due to the gradual departure from linearity. The 2° offset yield was termed the surgical yield because it represents the strain at which a surgical needle would start to lose functionality. A nonlinear relationship (R) was observed between measured and calculated values. The relationship (R) proved to be a function of cold work by wire drawing as measured by the change in wire length (ΔL), R = a - b * In(ΔL). This suggests that engineers selecting materials for bending applications such as surgical needles cannot use tensile data alone to predict bend strength. Processing history must also be known. © 1993 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 143-152 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to examine the bonding process between hydroxyapatite-coated strain gauges and bone in order to continue development of a long term in vivo strain measurement device. Two types of commercially available hydroxyapatite (HA) particles were applied to the sensing surface of uniaxial strain gauges using a polysulfone solution as an adhesive. Characterization by scanning electron microscopy and x-ray diffraction (XRD) was used to determine materials property differences between the two powders. Interfacial strengths between the HA coatings and the strain gauges were tested and found comparable to interfacial strength obtained by a plasma sprayed HA coating on the surface of a titanium implant.Gauges were surgically placed on the periosteal surface of greyhound femora. Three groups of dogs were implanted with gauges for periods of 3, 6, and 12 weeks using cyanoacrylate, resorbable sutures, and cable ties to initially hold the gauge against the surface of the bone.Following euthanasia, the femora of the dogs were explanted and subjected to cantilever loading. Response of the implanted HA-coated gauges were compared to a control set that had been freshly glued onto the contralateral femur. Full response, that is, 100h% of the strain measurement with respect to the control, was obtained after 12 weeks in vivo. Attachment of HA-coated gauges with a circumferential suture showed bonding, while HA-coated gauges attached with cyanoacrylate did not bond to bone.After mechanical testing, femora were embedded in polymethylmethacrylate, cut, ground, and polished. Sections were stained using mineralized bone stain (MIBS) and optical microscopy was performed using transmitted and fluorescent light to allow analysis of remodeling occurring in the region of the strain gauges. Bone formation occurred at the HA surface of sutured gauges, and a fibrous tissue layer developed between the bone and HA coating when the tissue adhesive was used to initially bond the gauge. Fluorescence microscopy indicated an increase in the number of areas of bone remodeling adjacent to the gauge but a normal rate of remodeling of 0.93 ± 0.07 μm/day was observed. No gross bone remodeling due to strain gauge placement was observed. Backscattered electron imaging (BSE) indicated new bone apposition at all time periods. © 1993 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 169-181 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The purpose of this paper is to examine the performance of the newly available monofilament polypropylene suture (Surgipro) manufactured by U.S. Surgical and compared it with commercial Prolene sutures for determining the merit of this new suture. Two different sizes of Surgipro sutures were esused. They were 4/0 and 0 sizes and were tested in terms of their fundamental properties: level of crystallinity, melting temperature, fiber morphology, and mechanical properties including knot strength and knot security. The effect of three different sterilization methods on the mechanical and fundamental properties of the new polypropylene (PP) sutures was also examined. In general, the new Surgipro sutures performed as good as Prolene sutures in terms of mechanical properties; but there were some differences in fundamental properties between these two types of PP sutures, particularly in finer size PP sutures. The major differences were in interior fiber morphology, level of crystallinity, and melting temperature. Surgipro suture fibers showed homogeneous interior morphology, while Prolene fibers exhibited two distinctive fiber morphologies. These two types of PP suture fibers also responded differently to the three sterilization methods tested. Surgipro sutures are less affected by different sterilization methods than the same size Prolene control. Except for the Co60 gamma sterilization, Surgipro suture fibers did not exhibit statistically significant differences in tensile breaking strength between sterilized and control. Ethylene oxide and autoclave sterilized Prolene suture fibers, however, showed statistically (p 〈 0.05) consistently lower tensile breaking strength than their unsterilized controls. One should be aware of the fact that suture manufacturers are constantly improving their manufacturing processes. The difference between these two types of PP suture fibers may disappear in the future. © 1993 John Wiley & Sons, Inc.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 183-194 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The failure of most percutaneous devices (PD) is caused by infection initiated by a lack of a tight seal at the skin-device interface. This interface can be disrupted by both extrinsic and intrinsic forces. Many stress reduction methods have been proposed, the most common being the application of a subcutaneous flange. It is widely believed that the bending compliance of the flange plays a significant role in the success or failure of a PD.A study was conducted to observe the effect of flange compliance on local host response in both a functional and nonfunctional setting. Two PDs having flanges with different bending rigidities were implanted percutaneously in goats (n = 8). After a healing period of 2 weeks, half of these devices were externally stimulated with a random load. All the implants were retrieved after 4 weeks and evaluated histologically.The tissue capsule was significantly thicker and the incidence of severe fibrosis and/or necrosis was higher at the flange rim of the functional implants, irrespective of flange compliance. The more compliant devices were encapsulated with a thick fibrous capsule more frequently than the less compliant ones, irrespective of functional status. The more compliant devices also had a greater incidence of foreign body giant cells in the corner region and elicited severe acute inflammation at the corner and top of the flange more frequently than the less compliant implants. Numerous areas of degenerating foreign body giant cells accompanied with fibroblastic proliferation and dystrophic mineralization were identified in many of the capsules beneath the flanges.It was concluded that the rigid implants elicited a more desirable tissue response than the compliant implants while the functional implants elicited a less desirable response than the nonfunctional ones. There was no synergistic or antagonistic relationship between the functional status of the device and flange compliance. © 1993 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 273-276 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The application of superselective endovascular occlusion in vascular radiology has broadened the scope of possible radical surgery of giant angiodysplasias by reducing considerably the risk of severe haemorrhage during the surgery. Occlusion was performed on 229 patients using spherical and cylindrical particles of porous poly(2-hydroxyethyl methacrylate). The treatment of a patient suffering from angiodysplasia of the pelvis is described as an example. The first day following endovascular occlusion a hypercoagulation reaction developed, with a decrease of both the level of fibrinolysis and of anticoagulant factors. This was mainly due to a decrease of the level of antithrombin III and activation of the factor XIII indicating a strong tendency of intravascular thrombosis. During the third day, the hypercoagulation reaction increased. However, on the fifteenth day, parameters of the haemostasis system were close to normal values. Only the activity of the factor XIII remained high suggesting the stabilization and the organization of fibrin clot in the embolized blood vessel territory. © 1993 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 363-363 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 365-365 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 97-101 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study evaluated the biocompatibility of an unfilled, fluoride-releasing acrylic resin by subcutaneous implantation in guinea pigs. The experimental fluoride resin was compared to a nonfluoride, dental pit and fissure sealant (DELTON) of similar composition. Thirty-four male albino guinea pigs received four Teflon® tubes each, implanted in the dorsal area. The tubes were open at both ends, three contained the experimental fluoride resin and one held the nonfluoride resin. The tubes and surrounding tissue were excised in 1-2 cm blocks, by necropsy, at 14 and 84 days. Histological evaluation showed that inflammatory response was none-to-slight at 14 days for 95% of the fluoride and 100% of the nonfluoride specimens. Five percent of the fluoride specimens produced a moderate tissue response. At 84 days, inflammatory response was none-to-slight for 82.5% of the fluoride and 61.5% of the commercial nonfluoride specimens, while 17.5% of the fluoride and 38.5% of the nonfluoride specimens produced moderate tissue responses. Chi-squared analysis and Fisher's Exact test revealed no statistically significant difference (p ≤ 0.05) in tissue response between the two resins at either 14 or 84 days. Hence it is concluded that the experimental, fluoride-releasing resin produces a very mild subcutaneous tissue response and that its biocompatibility is comparable to that of a widely used nonfluoride dental resin. It can, therefore, be considered as having a high potential for biological safety as a dental restorative resin or adhesive, or for other biomedical applications. © 1993 John Wiley & Sons, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993) 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 1-12 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This article describes preliminary biocompatibility screening of three degradable phosphate fibers containing K+, Ca+2/Na+ and Na+/Ca+2/Al+3 ions in the polymer chain, and of several different degradable polymers reinforced with these fibers. Biodegradable phosphate fibers of calcium-sodium-metaphosphate (CSM) and sodium-calcium-aluminum-polyphosphate (NCAP) were acutely nontoxic in cellular, tissue, and whole animal evaluations, as determined by standard acute toxicity tests. Histological studies of bone implants sites fabricated from composites of copolymers of poly(E-caprolactone/L-lactide) and poly(ortho ester) reinforced with either CSM or NCAP fibers showed these composite materials to be nontoxic, with no abnormal inflammatory response. However, histological evaluation of muscle implants sites revealed the appearance of necrotic foci associated with implant sites in 12 of 22 NCAP containing composite specimens (p 〈 0.05). Results of this preliminary biocompatibility screening suggest CSM fibers may be useful in reinforcing degradable polymers for production of completely biodegradable composites for implant use. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 29-38 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The interface between bone and a bioactive glass cement - a mixture of bioactive glass powder and ammonium phosphate solution, previously reported on by the authors - was evaluated quantitatively and histologically. The materials tested were (1) the original bioactive glass cement (BCI cement); (2) an improved type of bioactive glass cement (BCII cement); (3) polymethylmethacrylate (PMMA) bone cement; and (4) a bioactive, apatite-wollastonite-containing, glass ceramic (A-W·GC). Hardened cylindrical specimens of each cement were inserted loosely into canine femora and the interfacial shear strengths were measured using a push-out test. The interfacial strength values of the bioactive glass cements increased with prolonged implantation time. At each postimplantation time studied (8, 12, and 24 weeks), the interfacial strength value of BCI cement did not differ significantly from that of A-W·GC. BCII cement interfacial strength was greater than that of BCI cement, whereas the interfacial strength of PMMA bone cement remained at a very low level throughout the study. Histological examinations revealed that direct bonding of both bioactive glass cements to bone had occurred without pathologic degradation. After 24 weeks, the defects between the bone and the bioactive glass cements had been filled with mature lamellar bone. Because the bioactive glass cement system developed by the authors, especially BCII cement, shows excellent osteoconductivity and bonds to bone tightly, we consider it to be a promising material for fixing prostheses into bone. © 1993 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993) 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 195-209 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Organizing and accessing biomaterials-related information is problematic because of the interdisciplinary nature of the field. Relevant information appears in the literature of numerous science and technology subdisciplines and there is no one index or database that covers all of the related publications. An additional barrier to information retrieval is the lack of a thesaurus for the field. Multiple terms representing the same concepts are currently employed and it is not always readily apparent which terms to use in a literature search. As an aid for students and researchers in the discipline, the author provides an indexed bibliography of English language monographic works on biomaterials and biocompatibility published after 1973. © 1993 John Wiley & Sons, Inc.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Median nerve regeneration was studied in 30 adult primates after repair by microsurgical suture or tubulization with a nonwoven, bioabsorbable, polyglycolic acid device. The two methods were compared electrophysiologically and histologically 6 and 12 months after repair. The electrophysiology included recording of electrically evoked compound action potentials and subsequent determination of threshold, conduction velocity, amplitude, and area above the baseline for each component. Measurements were obtained before nerve transection and at the time of biopsy by stimulating both proximal and distal to the transection site. Analysis of all electrophysiological parameters revealed no statistically significant differences (p 〈 0.05) between the two repair techniques. Histopathology included examination of cross sections proximal and distal to the repair sites and longitudinal sections through the coaptation site. End organs (Meissner's and Pacinian corpuscles and muscle) were sectioned to determine the degree of reinnervation. No significant differences between the repair techniques were observed by histological analysis of these sections. These evaluations indicated that the tubulization repair technique produced results comparable to that of the suture technique. © 1993 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 277-277 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 13-27 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study focuses on examining the biological response of intramedullary bone to poly-L-lactic acid (PLLA), particularly during the PLLA degradation phase. To study the influence of spherical crystals (spherulites) of PLLA on intramedullary bone response, two different types of PLLA coupon, with and without spherulites but with the same molecular weight, were used. Chambers containing PLLA coupons were implanted into the right femur of eight dogs, four with and four without spherulites; chambers containing stainless steel (SS) coupons (as a control) were implanted in the left femurs of all eight. Two dogs, one with and one without spherulites, were sacrificed at 3, 6, 12, and 24 weeks postoperatively. Histomorphometric evaluation and histophathological assessment were used to compare the response to PLLA and SS. Scanning electron micrographs showed that there were minimal changes in the surface of PLLA coupons at 3 and 6 weeks. But at 12 and 24 weeks, there were many cracks and holes on the surfaces of the coupons, and some parts of the surface were scaling off. The cross-sectional area of PLLA coupons showed no change at 3 and 6 weeks, but started to decrease by 12 weeks. The amount of ingrown bone between PLLA coupons was significantly greater than that between SS coupons at 3 and 6 weeks, but had decreased dramatically by 12 weeks. Extensive bone resorption around PLLA coupons occurred by 12 weeks accompanied by infiltration of inflammatory cells. An abundance of histiocytes, giant cells, and leucocytes were seen, along with a few histiocytes that had phagocytized PLLA particles of less than 2 μm. By contrast, no inflammatory reaction was seen in SS samples at any period up to and including 24 weeks. PLLA demonstrated excellent biocompatibility with intramedullary bone for the first 6 weeks in this model. Once degradation commenced, however, biocompatibility decreased dramatically. Our study detected no difference between coupons with and without spherulites. It thus appears that the existence of relatively large PLLA particles did not influence the response of intramedullary bone to PLLA, but rather that it was the smaller particles (〈 2 μm) released from the PLLA that induced foreign-body inflammatory reactions and bone resorption. It is also possible that a local decrease in pH occurred around PLLA coupons, which could have influenced vital kinetics. © 1993 John Wiley & Sons, Inc.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 39-46 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An in vivo investigation of a new high molybdenum and nitrogen duplex stainless steel (25Cr—7Ni—4Mo—0.3N) has been performed. Cylindrical pins and specially developed devices, to test in static conditions the in vivo localized corrosion resistance, made of this new duplex steel and of a common austenitic stainless steel were implanted in rabbit's femurs for 6 and 12 months. After sacrifice, SEM observations and EDS microanalyses to detect metallic ion release were carried out on the femur sections surrounding the pins. Morphologic observations with stereoscope and SEM were performed on the metallic surfaces of the special devices in order to detect the presence of localized corrosion. Both ion release and localized corrosion were observed for the specimens made of austentic stainless steel, but not for those made of 25Cr—7Ni—4Mo—0.3N duplex stainless steel. © 1993 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A variety of methods have been recorded for the assessment of altered cellular functions caused by biomaterials. Cell membrane integrity can be determined by different tests depending upon the cell membrane permeability to various markers. To measure the degree of cell damage, we have chosen to compare the release of two markers in the supernatants: enzyme lactate dehydrogenase (LDH, which we wanted to compare to that of radioactive chromium preincorporated in cells, the latter being validated by a standard), from three cell types: cells from a fibroblastic cell line (3T3 Balb/c) and human differentiated endothelial cells and osteoblasts, exposed to injurious agents and to biomaterials of classical use. The labeling procedure as well as the incubation periods performed, were carried out according to a standard. Celllabeling efficiency ranged from 4 to 10%. The biomaterials tested provoked no or slight cell membrane damage. After linear regression analysis, we found high coefficients between chromium release and LDH release.Thus, the determination of LDH activity, which is easy to manipulate, could be a satisfactory test to evaluate cell membrane integrity in contact with biomaterials and a prerequisite stage before the more sophisticated 51chromium release test. © 1993 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 303-307 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A simple, yet specific, means to identify submicron polyethylene (PE) particles in routine histologic sections would be practically useful. We have previously reported a very fine, diffuse, birefringence (when viewed under polarized light) in the cytoplasm of phagocytic cells from around total hip replacements (THRs) with a PE acetabular bearing and proposed that this finding was caused by multiple submocron PE particles. In order to determine the specificity of this light microscopie finding, we have analyzed a wide range of specimens (N = 27), characterized by a foreign-body inflammatory response to both biologic and prosthetic material, that do not contain PE. In no case was there any suggestion of the diffuse cytoplasmic birefringence that is characteristic of specimens from THRs with a PE acetabular bearing surface. This study indicates that, within the range of orthopedic implant materials and designs currently in use, this diffuse birefringence is a specific finding and it represents a simple, practical, and useful method for ligh microscopic identification of submicron PE. © 1993 John Wiley & Sons, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 359-361 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To assess new and existing materials for total joint arthroplasty, the authors performed a comprehensive histomorphologic and morphometric analysis of bone to cylinders implanted transversely in the proximal tibia of mature New Zealand white rabbits. Four sterile, cylindrical implants measuring 6.1 × 3.8mm were manually inserted through drill holes in both tibiae with a „line-to-line fit.“ The materials tested included: ASTM F-75 cast cobalt-chrome-molybdenum alloy, commercially pure titanium wrought zirconium-2.5 niobium alloy, zirconium oxide coated zirconium-2.5 niobium alloy, wrought titanium-13 niobium-13 zirconium alloy, and nitrogen diffusion hardened titanium-6 aluminum-4 vanadium alloy. Control animals with or without drill holes were included. The animals were killed by barbiturate overdose 6 months postoperatively. The upper tibiae were harvested and processed for undecalcified histologic sections that were stained with toluidine blue. The sections were examined by an investigator blind to the identity of the implanted materials. A full necropsy was also performed.A collar of lamellar bone, of variable length and thickness, continuous with the original cortex formed a buttress around the implants. There was no evidence of foreign body or inflammatory reaction. The marrow was slightly fatty, but cells of allthree hematopoietic lines were identifiable. The materials investigated had the following ranking in decreasing order of bone contact: Ti-13Nb-13Zr 〉 nitrogen hardened Ti-6Al-4V 〉 C.P. titanium 〉 Zr 2.5Nb 〉ZrO2 coated Zr-2.5Nb 〉 cast Co—Cr alloy. The difference between the groups was statistically significant (p = 0.05). For the variable „average bone layer thickness“ the ranking in decreasing order was: nitrogen hardened Ti-6Al-4V alloy = C.P. titanium 〉 Ti-13Nb-13Zr 〉 ZrO2/Zr-2.5Nb 〉 Zr-2.5Nb 〉 cast Co—Cr alloy (p = 0.19). For the variable „average bone layer thickness in bone contact regions,“ the ranking of the values, in decreasing order were: nitrogen hardened Ti-6Al-4V 〉 C.P. titanium 〉 ZrO2 coated Zr-2.5Nb 〉 Ti-13Nb-13Zr 〉Zr-2.5 Nb 〉 cast Co—Cr alloy (p = 0.02). The final necropsy reports of the animals identified no adverse findings that were concentrated to any particular implant group. The new, lower modulus materials Ti-13Nb-13Zr and Zr-2.5 Nb, and nitrogen hardened Ti-6Al-4V appear to have a similar or superior bone response to Co—Cr alloy when implanted in the rabbit tibia model. © 1993 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 347-354 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A vascular graft with the inner diameter of about 3 mm was prepared from segmented poly (ether urethane) with an extrusion technique. To make the wall of the vascular grafts porous, NaCl salts were added to the polyurethane solution to be extruded and removed with water extraction after evaporating the solvent in the extruded tube. The wall was reinforced with elastic fiber to prevent dilation. The compliance of the vascular graft measured with the method of Hayashi et al. ranged from 0.2 to 0.3% mmHg-1. The initial Young's modulus was close to that of canine carotic artery, to which the porous polyurethane graft 4-cm long was anastomosed. Vascular grafts were occluded within 2 weeks after implantation, when their pore size was 0, 1.7, or 4.4 m̈m, whereas those with the pore size of 5.5, 7.4, and 30 m̈m were patent for longer than 4 weeks. When the vascular graft with the pore size of 30 m̈m was implanted for 6 months, the luminal surface was covered with neointima, but the endothelium-like cells appearing in the middle of the intima of the vascular graft were immature and sometimes had a very big nucleus. In addition, spindle-shaped, modified smooth muscle cells were noticed in the deep layer of the neointima, especially in the tissue where anastomotic intimal hyperplasia occurred. © 1993 John Wiley & Sons, Inc.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 114-114 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 15-20 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: An isoparametric plate shell element of 16 nodes and 40 degrees of freedom is developed in this paper directly from 3-D elastic theories. In order to overcome the difficulties caused by straightforward use of a 3-D formulation, the relative displacement method is introduced. For curved shell elements, the use of the orthogonal curvilinear co-ordinate system greatly reduces the computer effort. The new element can conveniently solve shell problems with variable thicknesses and also easily link with other finite elements using displacement d.o.f. such as 8-node to 21-node 3-D elements. Numerical examples demonstrate the efficiency of the element.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 27-34 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The behaviour of a Hermitian two-node element based on the Bernoulli beam equation is examined. The assumed constraints generate rotation-dependent distributed moments. It is shown that for these moments a potential exists, and that a rigid translation is the only rigid body mode of the element. The analysis of the Bernoulli equation demonstrates that very large values of α= e/EI enforce the condition w,x = 0, resulting in displacements equal to zero. The element is examined for two types of constraints. The first type of constraint, diminishing rotations of a beam (α 〈 0), yields regular solutions which, however, seem to have a non-differentiality near the end of the beam. A special procedure is developed to evaluate analytical solutions for long beams or stiff constraints, for which computer accuracy is exceeded. For the second type of constraint, enlarging rotations of a beam (α 〉 0), a highly oscillatory nature of the solution is proven.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 293-305 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Explicit finite-element programs, such as DYNA3D, are frequently used to solve large structural problems, such as automobile impacts, that involve tens of thousands of shell elements. Since the explicit finite-element programs do not use a stiffness matrix, the major cost of the calculation is the evaluation of the force vector. A significant part of that cost is the evaluation of the constitutive models. The standard algorithm for integrating J2 plasticity at the stress points is the radial return method. An iterative variation of radial return is commonly used to impose the zero normal stress condition within the shell elements. In this paper we explore several different non-iterative methods that impose the zero normal stress condition in an approximate manner. We show that the cost of the constitutive evaluation can be reduced by 25 per cent without introducing significant errors.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 307-311 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Recently a bicubic transformation was introduced to numerically compute the Cauchy principal value (CPV) integrals. Numerical results show that this new method converges faster than the conventional Gauss-Legendre quadrature rule when the integrand contains different types of singularity. Assume η is the singular point of a CPV integral. The point η divides the interval [-1, 1] into two parts: [-1, η] and [η, 1]. The bicubic transformation maps the intervals [-1, η] and [η, 1] to the interval [-1, 1] with the following constraints: it maps the point η - ∊ to μn, and η + ∊ to -μn, where μn is the largest Gaussian point of an n-point Gauss-Legendre quadrature rule, and ∊ is a user-supplied constant. The n-point Gauss-Legendre quadruture rule is then applied. In contrast to ordinary expectation, further numerical experiment shows that smaller ∊ does not always produce better results. In this paper we are concerned with the selection of ∊ to yield rapid convergence of numerical integration when the bicubic transformation method is applied.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 157-164 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: In the Eulerian description of metal forming operations usually rigid/incompressible viscoplastic material models are used. In this paper a quadrilateral 2-D finite-element formulation for incompressible viscoplastic flow analysis is developed. The element (QMITC) is based on mixed interpolation of tensorial components, and the incompressibility constraint is imposed via the penalty method. It is shown that the resulting element does not lock either in plane strain rate flows or in axisymmetric flows, that the oscillations in the pressure predictions (checkerboard) tend to zero when the mesh is refined and that the solutions for some typical benchmark problems are very accurate.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 177-179 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 165-175 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The static bifurcation criterion, i.e. singularity of the tangential stiffness matrix, is discussed in the sense of non-linear dynamics since it is sometimes used in the engineering literature. In this paper the connection between static stability, i.e. that the tangential stiffness matrix is positive-definite, and insensitivity, i.e. local damping of small perturbations, is proved. Since, in general, there is no connection between insensitivity and asymptotic stability, the concept of sensitivity cannot replace the classical stability theory of motion.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993) 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 181-187 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A relaxation-like method for the numerical solution of a class of partial differential equations of mixed type is presented. The equations of this class have not yet been solved by functional outlines. The numerical method does not add artificial terms to the original equation.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 189-196 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The paper is concerned with the solution of non-linear wave distribution in structural fibre members subjected to dynamic kinematic forcing. The development of reliable and efficient techniques for numerical handling of wave distribution based on the application of combined finite-element and transfer matrix approaches is emphasized. Illustrative numerical solutions are presented.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 197-206 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: This paper deals with the solution of the one-dimensional advection-diffusion equation. The method of solution is based on the process-splitting technique. The transport equation is split up into the advection part and the diffusion part at every time step. The advection transport equation is solved by a method of characteristics using a spline function for interpolation. This solution approach proves to be very effective because it reduces numerical dispersion and wiggles. The diffusion equation is solved by the standard Galerkin finite-element method. A comparison of calculations with the results of Holly and Preissmann and with analytical solutions demonstrates the great accuracy of the proposed method.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 417-426 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A 12-DOF quadrilateral element for plate bending is formulated based on the concept of generalized compatibility and semi-Loof constraints. The element DOFs are defined with the conventional displacements at corner nodes and the semi-Loof constraints are used in the formulation. This element is a generalized conforming one which passes Irons' patch test and can be used to solve problems with complicated boundaries. When overall considerations of simplicity, accuracy and reliability are taken into account, this new element is one of the best 12-DOF quadrilateral plate-bending elements currently available.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 439-450 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The classical Gauss-Laguerre quadrature rule for the semi-infinite integration interval [0,∞] is modified and applied to the case of the weight function exp(-x)/x corresponding to finite-part (or, equivalently, hypersingular) integrals. The new set of orthogonal polynomials is constructed and it is seen to consist of linear combinations of the classical Laguerre polynomials with appropriately determined coefficients. The zeros of these modified Laguerre polynomials are seen to be distinct, but one of these lies outside the integration interval. Formulae for the corresponding weights are also given and numerical values and results are presented. The present results generalize the corresponding results for the finite interval [0,1] to semi-infinite intervals and they are applicable to a variety of applied mechanics and related problems, where finite-part integrals appear in a natural way.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 455-461 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The virtual contact loading method (VCLM), a highly efficient numerical method to solve elastic contact problems, is proposed in this paper. Having applied virtual loads on the possible contact region (PCR) of a structure system, we carried out the usual finite-element calculations only once and made a local iteration analysis in PCR then the contact region (shape and size), contact state (stick, slide or mixed), contact normal and shear stress distributions, and the stress and displacement fields in contact bodies were all obtained simultaneously. This method is very simple and easy to use.The elastic contact problems for cylinder-cylinder are solved in this paper and the results agree well with those in previous work.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 483-488 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: In this paper a new method has been presented to determine the optimum number of knots for cubic splines. The knot-finding process is based on the numerical integration of the input curve. The number and the location of the knots is determined automatically. The method has been applied to a test case and the performance has been compared with two other existing methods. It is shown that fewer knots are retained for the portions of the curve having small curvature whereas a larger number of knots is retained for highly curved portions. The computer time required by our method depends only upon the number of points in the input curve and does not depend upon the shape of the curve or the desired accuracy.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 475-482 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The radiation boundary condition is frequently used at the artificial outflow boundary created in the numerical computation of fluid flow problems to allow outgoing waves to leave the domain undisturbed. However, the numerical approximation of the radiation boundary condition will produce errors which will affect the interior solution. In this work the errors due to two different numerical approximations of the radiation boundary condition are studied, with the one-dimensional wave equation being used as the model equation. A theoretical analysis shows that: (a) if the numerical approximation of the boundary condition generates a celerity error, a reflected wave with amplitude proportional to the size of the celerity error is produced; (b) if the numerical approximation of the boundary condition generates a numerical diffusion and hence an amplitude damping error, a reflected wave with amplitude proportional to the magnitude of the numerical diffusion is produced. A modification of the Sommerfeld radiation boundary condition to account for the linear bottom friction effect is investigated. Numerical experiments show that the use of the backward characteristics scheme with quadratic interpolation is able to reduce significantly the reflection of the wave at the outflow boundary and that the scheme is unconditionally stable.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 489-495 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A method for analysing eigenvalues of the Helmholtz equation using a standard existing subroutine for eigenvalue determination is developed in this paper. It is based on the boundary integral equation formulation known as the multiple reciprocity method (MRM). The above-mentioned formulation, having polynomial matrices in terms of the eigenvalue as the coefficient matrices, is transformed into the standard-type eigenvalue problem. The resulting formulation makes it possible to determine the required eigenvalues only by boundary discretisation without any initial rough estimation.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 511-523 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: We give a posteriori error bounds for numerical solutions of regularized compressible flow problems. To verify the efficiency of our method, numerical experiments are performed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 503-509 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The integral transform method is used to compute numerically the development of the velocity profile in the hydrodynamic entrance region for laminar flow inside a parallel plate channel. The results have user-prescribed accuracy and can be used to test other numerical methods.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 497-501 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The completely adhesive contact between an FE-modelled orthotropic half-plane and a vertically loaded rigid flat punch is studied. Interface normal and shear-stress distributions between the punch and half-plane are FE-calculated and compared for some sets of half-plane boundary conditions frequently used in the literature for contact problems with friction. These results are compared with analytical solutions, and appropriate half-plane boundary conditions are recommended for frictional contact problems.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 543-545 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993) 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 533-542 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The computer code FIDAS-3DT, developed by Power Reactor & Nuclear Fuel Development Corporation of Japan, has been used to solve by the finite-difference method an air-water horizontal annular flow problem based on two-phase, three-fluid and two-component velocity modelling. In an attempt to improve the water flow rate results, as compared with those of a reported experiment, several corrections applied to the code are investigated, and the recommended technique is presented.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 547-554 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: An adaptive refinement procedure using a new automatic quadrilateral element mesh generator is presented. The performance of the adaptive procedure in achieving a given accuracy with different mesh refinement strategies is compared. It is found that when using bilinear or biquadratic quadrilateral elements refinement strategies of both mesh enrichment and mesh regeneration can lead to a prescribed accuracy being achieved by the Zienkiewicz-Zhu adaptive procedure1 with the optimal rate of convergence. However, fewer mesh refinement steps are needed if the strategy of mesh regeneration is employed with the newly developed automatic quadrilateral element mesh generator2.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 555-566 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The network generation method described herein produces two-dimensional irregular triangular grids in which element area is proportional to some scalar density function defined over the domain. This density function can reflect arbitrarily chosen properties of the geometry or flow. After the initial generation, various adjustment utilities and an interactive (graphic-based) editor ensures that the resultant triangular elements are well shaped. Some of these utilities can be used with adaptive refinement schemes.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. i 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 313-329 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: This paper examines the suitability of three-dimensional finite elements to model accurately problems involving material incompressibility, using the displacement finite element method and exact numerical integration. The previously used method for classification of element suitability is presented and extended to the three-dimensional case. However, an alternative approach for examining suitability, quantified in terms of free degrees of freedom (equal to the degrees of freedom minus the incompressibility constraints), is introduced. This is used to examine Lagrangian cubic, serendipity cubic and tetrahedral three-dimensional elements configured in a regular cubic arrangement. The findings of this paper are substantiated by a number of three-dimensional numerical experiments and comparison with a separate two-dimensional study.All serendipity cubic elements are found to be unsuitable. The linear strain tetrahedron is on the borderline of suitability in a 6-tetrahedra-per-cube arrangement, and is thought to be only suitable if the mesh boundary nodes are not over-constrained. The same element in a 5-tetrahedra-per-cube arrangement, and higher order tetrahedra (quadratic strain etc), are suitable. The Lagrangian cube elements of higher order than the 27-node cube are suitable, but are probably not as efficient computationally as the tetrahedral elements of the same order.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 331-336 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: An algorithm is presented for the inclusion of general strain-hardening/softening behaviour into the direct method of finite-element analysis of elasto-viscoplasticity using implicit time discretization.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 337-343 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A numerical method is presented for the evaluation of field singularities of the type (1/r1-λ) using iterative solutions of standard boundary-element analyses in a region surrounding the origin of singularity. Results for λ are presented for both two and three-dimensional problems, and representative asymptotic fields for these examples are discussed.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 345-351 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: It is shown that a triangular membrane finite element with vertex ‘drilling rotations’ which was developed in earlier publications is, in fact, a correct implementation of a variational principle. The existence of a variational principle is a crucial factor which places the earlier work on a secure theoretical foundation. It implies superior computational characteristics of the finite-element equations and provides valuable guidance on practical issues such as the consistent treatment of boundary conditions.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 361-363 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993) 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 353-359 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: This paper presents an algorithm for obtaining the inverse of a tridiagonal matrix numerically. The algorithm does not require diagonal dominance in the matrix and is also computationally efficient.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 207-217 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A posteriori error indicators for strain energy error in finite-element solutions have recently been shown to be effective. A popular error indicator, usually denoted by η, makes use of ‘error energy’, i.e. strain energy associated with the difference between the conventional element stresses σ and a smoothed stress field constructed from σ. It is intended that η be constructed by summing element contributions and that it be applied at the global level. The present study suggests that an error indicator applicable at the element level can be obtained by combining an element value of η with information about stress gradient and strain energy density. It is also shown how the stress gradient information can be used to obtain more accurate stresses at mesh boundaries.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 233-241 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The Neumann-Neumann algorithm is known to be an efficient domain decomposition preconditioner with unstructured subdomains for iterative solution of finite-element discretizations of difficult problems with strongly discontinuous coefficients (De Roeck and Le Tallec, 1991). However, this algorithm suffers from the need to solve in each iteration an inconsistent singular problem for every subdomain, and its convergence deteriorates with increasing number of subdomains due to the lack of a coarse problem to propagate the error globally. We show that the equilibrium conditions for the singular problems on subdomains lead to a simple and natural construction of a coarse problem. The construction is purely algebraic and applies also to systems such as those that arise in elasticity. A convergence bound independent of the number of subdomains is proved and results of computational tests are reported.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 219-232 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The symmetric boundary-element method for mixed boundary-value problems is currently gaining increasing interest as it permits the derivation of symmetric matrices. It is even possible to obtain positive-definite finite-element stiffness matrices for BEM subregions, and therefore the method provides a very straightforward coupling to the finite-element method (FEM). The BEM subregions can be handled like FEM substructures in a domain decomposition context. The symmetric BEM uses the full set of integral representations for the 2n types of boundary data for self-adjoint problems of order 2n and solves them in a weighted residual (Galerkin) sense. The main difficulty of the method is caused by the need to compute hypersingular integrals arising from the integral representations of the Neumann boundary data. It is the object of the paper to show that, for 2-D problems on polygonal domains, these hypersingular integrands pose no problem at all, even for higher-order approximations. The present approach makes use of analytical integrations as far as possible. The integrals of the hypersingular expressions are derived completely within the framework of simple engineering mathematics. The problem is reduced to the computation of weakly singular integrals even for C0 continuous approximations.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 243-250 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The potential distribution of bipolar, strongly reverse-biased pn-junctions can be described by a double obstacle problem for the Laplacian. The problem is solved by a self-adaptive finite-element method involving automatic termination criteria for the iterative solver, local error estimation and local mesh refinement. Special attention is paid to the efficient resolution of the geometries typically arising in semiconductor device simulation. The algorithm is applied to a reverse-biased pn-junction with multistep field plate and stop electrode to illustrate its efficiency and reliability.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 251-258 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A modification has been introduced to the new superconvergent patch derivative recovery technique recently developed (Zienkiewicz and Zhu, 1991). By use of a locally normalized co-ordinate system, the application of this technique can now be applied to higher-order finite-element shape functions. Numerical studies are carried out for up to 6th-order elements in one dimension and for up to quartic elements in two dimensions, and superconvergent results are obtained for all examples tested.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 269-271 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993) 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 259-267 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Two graph-theoretical algorithms are developed for bandwidth reduction of rectangular matrices. A K-total graph is defined for a selected cycle basis, generalized cycle basis and cut set basis of a graph. This transforms a simultaneous ordering of the elements of a basis and members of a graph into that of a nodal numbering of its K-total graph.The first algorithm uses the K-total graph and results in banded equilibrium and self-stress matrices. The second employs a nodal ordering algorithm followed by a member ordering process. This algorithm can be used for optimizing the bandwidth of member-cocycle incidence matrices, resulting in banded equilibrium matrices.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 273-292 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A simple a posteriori local error estimator for time discretization in structural dynamic analysis is presented. It is derived from the difference of the solutions between an ordinary integration method (the Newmark scheme) and another higher-order one which assumes that the derivatives of accelerations vary linearly within each time step. It may be obtained directly without resolving new equations, so the additional computational cost is small and the implementation is convenient. Furthermore, it is shown that this error estimator may also be obtained by Taylor expansion or by a post-processing technique. Accordingly, an adaptive time-stepping procedure, which automatically adjusts the time-step size so that the local error at each time step is within a prescribed accuracy, is described. Numerical examples, including two single-DOF problems, a two-DOF problem and a multi-DOF model, are presented. The results show that the presented local error estimator is simple, reliable and accurate.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 579-586 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A combination of the splitting method and the cubic spline technique has been used to solve a non-linear regularized long wave (RLW) equation. The accuracy and the stability of the proposed method are discussed. Then, two numerical examples are solved to illustrate the robustness of the algorithm. The results are in good agreement with the available results.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 9 (1993), S. 587-594 
    ISSN: 1069-8299
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The solution of the stream function-vorticity equations is developed using a multigrid method to improve efficiency in a finite-element p-method. The equations are discretized using 2-D Lagrange finite elements (linear, quadratic and cubic) and solved in iteratively decoupled form using successive approximation and continuation methods. The comparative performance of several multigrid and direct matrix solvers is investigated with respect to convergence characteristics and time performance on the Cray Y-MP.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...