ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (2)
  • Ablation  (2)
  • 2010-2014
  • 1990-1994  (2)
  • 1985-1989
  • 1950-1954
  • 1990  (2)
  • Technology  (2)
  • History
Collection
  • Articles  (2)
Publisher
Years
  • 2010-2014
  • 1990-1994  (2)
  • 1985-1989
  • 1950-1954
Year
Topic
  • 1
    ISSN: 1435-604X
    Keywords: Laser lithotripsy ; Salivary calculi ; Pulsed 504 dye laser ; Ho-YSGG laser ; Ablation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract The feasibility of laser lithotripsy of salivary stones was investigated. Two types of laser systems were evaluated: a 504 nm flashlamp pumped dye laser and a Ho-YSGG laser. With the dye laser, plasma flashes and acoustic phenomena could be observed. The number of laser shots per unit mass necessary to fragment the stone decreased in proportion to the energy per laser pulse to the power −2.7. With the Ho-YSGG laser, a more ablative kind of stone decomposition was observed. Here the number of shots per unit mass necessary for fragmentation was inversely proportional to the energy per laser pulse. For both lasers the total time necessary to fragment the stones is much too long to compete with conventional stone removal.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Lasers in medical science 5 (1990), S. 365-373 
    ISSN: 1435-604X
    Keywords: Erbium-YAG ; Holmium-YAG ; CO2 ; Infrared ; Laser ; Bone ; Ablation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract Results are presented for the latent heat of ablation of bone using an erbium-YAG laser operating at 2.9Μm, and a holmium-YAG laser operating at 2.1Μm. The values are 8.2±1.0 kJ cm−3 and 18±2.0 kJ cm−3, respectively. Secondary damage to surrounding tissue is found to extend approximately 5Μm with the erbium laser and is greatly increased to 80Μm with significant charring in the case of holmium. These secondary damage zones are much smaller than those produced by the CO2 laser.
    Type of Medium: Electronic Resource