ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Other Sources  (564)
  • INSTRUMENTATION AND PHOTOGRAPHY  (564)
  • 1980-1984  (564)
  • 1984  (306)
  • 1983  (258)
  • 1
    Publication Date: 2004-12-04
    Description: An improved 4 to 18 micron array camera system was developed at NASA Goddard SFC for astronomical photometry, using an Aerojet Electro Systems Corp. 16 x 16 Si:Bi accumulation mode charge injection device (AMCID) which could be suitable for eventual low-background spaceflight applications. An astronomical observing program using this device was carried out as a collaboration between NASA Goddard (Infrared and Radio Astronomy Branch and Micro Electronics Branch), the Harvard/Smithsonian Center for Astrophysics, and Steward Observatory of the University of Arizona. In 1983 the camera system was revised, and a new Aeroject Si:Bi array with 16 x 16 active pixels was obtained from NASA/Ames Research Center as part of a new scientific collaboration between the Ames and Goddard infrared array research groups. The 16 x 16 device had sufficiently good sensitivity, uniformity and noise characteristics to be used for successful observations at the Mt. Lemmon 60 and 61 inch telescopes in May 1983. Complete laboratory characterization of the 16 x 16 array was carried out in summer of 1983. Initial results indicate that this detector has sensitivity and noise characteristics comparable to other devices from the same generation of Aerojet arrays.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Ames Research Center, Infrared Detector Technology Workshop; 12 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2006-02-14
    Description: The use of laser holography for measuring the distortion of antennas under space simulation conditions is described. The subject is the so-called double exposure procedure which allows to measure the distortion in the order of 1 to 30/micrometers + or - 0.5 per hologramme of an area of 4 m diameter max. The method of holography takes into account the constraints of the space simulation facility. The test method, the test set up and the constraints by the space simulation facility are described. The results of the performed tests are presented and compared with the theoretical predictions. The test on the K-Band Antenna e.g., showed a distortion of approximately 140/micrometers + or - 5/micrometers measured during the cool down from -10 C to -120 C.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center 13th Space Simulation Conf.; p 309-319
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2006-02-14
    Description: Conventional schemes for digitizing large volumes of photographic data are far too costly and time consuming to encourage the undertaking of the ambitious projects using traditional technology. There is a distinct need for fast digitizing systems such as could be derived from development of large format, optically multiplexed CCD systems designed to address these problems. The use of CCD chips for data handling and the capability of using polaroids in the optical path for reduced light scattering are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 419-427
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Parameters of the UK 1.2 meter Schmidt telescope are described. Plates taken with this instrument are in two categories, those for systematic sky surveys and those taken at the request of research users. A collaborative project with the European Southern Observatory was undertaken to obtain a two-color survey of the sky south of -20 deg declination to complement the Palomar survey. A near infrared survey of the Galactic Plane and the Megallanic Clouds is being done. The area south of -20 deg and the zone between 0 deg and -15 deg are also being surveyed. Pending a decision on survey parameters, all available A quality prism plates are being retained to form a basis for systematic survey. Nearly half the plates taken on a service basis for the UK astronomical community are to fulfill nonsurvey requests. Plates taken for surveys which are not of A grade quality are also made available for research purposes.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 379-385
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2006-02-14
    Description: Some software facilities used mainly for information retrieval and analysis at the Padova-Asiago Observatory are discussed. These facilities help guest and resident astronomers to make easier the preparation of plate measurements. The problems connected with the creation, use and management of a data base in a scientific (astronomical) environment are reviewed on the basis of the experience gathered during the last three years. The development plan of the user session environment and its possible applications in a computer network are briefly sketched.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 361-369
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: A 256 diode-array will be installed as detector on the ESO OPTRONICS S-3000 measuring machine in order to increase the acquisition rate. A high intensity LED will be used as light source in a pulse mode. The data will be stored on a random access mass storage device as density values for later education. The scanning time for a 30 cm x 30 cm plate with a step size of 10 micron will be less than 10 hours while the dynamic range of the data is expected to be 2.5 density units with an offset of at least 1 unit.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 317-328
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2006-02-14
    Description: The design and performance of the automated photographic measuring facility at Cambridge is described. It consists of a precision laser scanning microdensitometer connected to a series of computers that process the data on-line. Plates up to 350 mm square can be measured. The microdensitometer samples the plate to 12 bit accuracy at a speed of 230,000 samples/second. The positional accuracy is better than a micron. Other features include platen rotation and automatic focus.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 277-288
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The expected performance of the Minnesota automated dual-plate scanner (APS) is discussed with regard to photometry, position measurement accuracy, and ability to classify images. In addition, a fast algorithm for calculating image parameters is described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 267-276
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2006-02-14
    Description: Various aspects of the performance of the PDS 1010A microdensitometer are described. The primary points in an upgrade propsal for the unit are outlined. Photometric instabilities in the PDS are mentioned.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 129-134
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Minor modifications of electronic components in the PDS 1010A microdensitometer are discussed. The operational requirements and performance limitations of the PDS are noted. Replacement of the photomultiplier and front-end analog circuitry significantly improved the photometric performance of the PDS. The improvement in density repeatability is marked, and the permissible density slew speed is greatly increased.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 121-128
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Publication Date: 2006-02-14
    Description: High Altitude Observatory HAO microdensitometer undergoes monthly testing to assure its consistent performance. These tests check positional and photometric stability at the 10 micron aperture level. The HAO test procedure is designed to run without operator intervention following initial configuration of the microdensitometer for each subprocedure. Specialized test software is resident in the PDP 8. The operator selects the proper subprocedure by entering commands. Once computer control is established, it is not relinquished until the test is complete.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Astron. Microdensitometry Conf.; p 19-34
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Publication Date: 2006-02-14
    Description: A number of diagnostic tests are developed for the Photometric Data System PDS 2020G microdensitometer to monitor its performance and to isolate various electromechanical problems. A number of tests which help to diagnose problems with the photometer, positional accuracy and data collection are described. The tests include: (1) scanning a razor blade edge to study the response of the photometer and zero point losses in the coordinate system, (2) scanning a long straight line to evaluate the drunkness of the stage motions, (3) scanning photometric step wedge calibrations to study the response of the photometer, and (4) measurement of a series of high signal to noise plates of the same region of the sky to evaluate the overall performance of the microdensitometer. A variety of electronic tests to isolate electromechanical problems are also performed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 3-18
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The behavior of ruled and holographic gratings with various coatings after extended exposure to the space environments was examined. The coatings and differentiating between the influences of vacuum and solar illumination were examined. In the past, several ruled and holographic gratings with various coatings were successfully flown on rocket experiments. Future utilizations of such gratings are considered for the Space Telescope and for various Spacelab projects under development. The techniques which is used to replicate gratings can also be used to obtain a wide range of lightweight optical components, including sophisticated aspherical, highly polished mirrors.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 163-164
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Publication Date: 2006-02-14
    Description: Electro-optic holographic recording systems were developed. The spaceworthiness of electro-optic crystals for use in ultrahigh capacity space data storage and retrieval systems are examined. The crystals for this experiment are included with the various electro-optical components of LDEF experiment. The effects of long-duration exposure on active optical system components is investigated. The concept of data storage in an optical-phase holographic memory is illustrated.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 152-153
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Publication Date: 2006-02-14
    Description: The specific scientific objectives of this experiment are to measure the spatial distribution, size, velocity, radiance, and composition of microparticles in near-Earth space. The technological objectives are to measure erosion rates resulting from microparticle impacts and to evaluate thin-foil meteor 'bumpers'. The combinations of sensitivity and reliability in this experiment will provide up to 1000 impacts per month for laboratory analysis and will extend current sensitivity limits by 5 orders of magnitude in mass.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 117-120
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Publication Date: 2006-02-14
    Description: One of the principal advantages of electrography when compared to photography is the nearly linear relationship between source intensity versus resulting image density. This property allows for simplified and more accurate photometric calibration and permits a certain degree of extrapolation of the calibration to beyond the limits of the faintest photoelectric standard on an exposure. The desires to extract quantitative photometric information from electrographic (or photographic) negatives and to convert this information into a digital format for computer analysis or enhancement led to the widespread use of scanning microdensitometers to perform this A-to-D conversion. Therefore it is of vital importance to understand and, if practical, to avoid any nonlinearities which may be introduced during microdensitometry of electrographic emulsions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 429-431
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Publication Date: 2006-02-14
    Description: The scanning of a direct plate with the automatic plate measuring machine which results in the automated selection and description of images is described. The selection of QSO candidates based on color-color diagrams constructed from the APM image data and the analysis of APM raster data for QSOs selected visually from objective prism plates are also discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 417-418
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The fundamental limitations of microdensitometers are reviewed and the design of a high microdensitometer described. The system will digitize to 16 bits in transmission at a speed of 100 kHz using a laser beam moving over the emulsion. Other features are automatic platen rotation and autofocus. The cost will be of order $200,000.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 333-341
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: A new photographic measuring machine is under construction at the Paris Observatory. The amount of transmitted light is measured by a linear array of 1024 photodiodes. Carriage control, data acquisition and on line processing are performed by microprocessors, a S.E.L. 32/27 computer, and an AP 120-B Array Processor. It is expected that a Schmidt telescope plate of size 360 mm square will be scanned in one hour with pixel size of ten microns.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 329-332
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Publication Date: 2006-02-14
    Description: A diode-array based image digitizer manufactured by the Eikonix Corp. was tested to see if it can be adapted to the exacting requirements of astronomical densitometry. As the device is presently configured, a dynamic range of 400:1 can be achieved routinely, with a positional accuracy of 2 microns or better. An area of 2048 X 2048 pixels can be scanned in about 5 minutes. Preliminary tests indicate that several relatively simple enhancements can improve both the photometric and the positional accuracy of the device.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 307-315
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Motivations for construction of a next generation microdensitometer (NGM) are presented and their effect on the NGM design is discussed. A prototype of such an engine has been constructed at KPNO. Its design and performance is reviewed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 291-305
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The motivations for constructing a special purpose built microdensitometer are explored. The salient points of some of the microdensitometers are described and the advantages and disadvantages of the system in comparison to a PDS machine are outlined. The principal gain is in speed though at the expense of loss in dynamic range. The effects on the astronomical results are demonstrated. The astronomical results already obtained with these machines and from ongoing projects are described. It is shown that there is a large class of important astronomical problems which can be tackled by these machines but which are not feasibile on the PDS because of the speed of the machine.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 209-228
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Publication Date: 2006-02-14
    Description: The necessity to incorporate several hardware changes to optimize the Yale PDS 2020G microdensitometer for photometric and astrometric research are discussed. The properties of a new high speed photometer and a positional calibration system are described. The new photometer incorporates a high speed logarithmic analog to digital converter with more than 10 times the resolution of the former system and a cycle time of approximately 50 usec. The positional calibration system monitors the drunkenness of the stages with respect to fixed index lines and enables the correction of the +/- 5 micro stage errors to an accuracy of better than 1 micro.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 151-161
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The astrometric and photometric performance of the PDS 1010A microdensitometer are discussed, including the tests used for checking it. The instrument was shown to satisfy operational requirements for photometric measurements of astronomical plates with respect to dynamic range and stability.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 89-95
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Publication Date: 2006-02-14
    Description: The results of several parametric studies carried out on the Marshall Space Flight Center (MSFC) Photometric Data System PDS-10 microdensitometer are summarized for the purposes of documenting the operation and limitations of the system for inhouse research and to provide a bench mark for comparison with other microdensitometers. The results are grouped into four general areas. These are: (1) system overall stability to drift, (2) photometric linearity and noise, (3) reproducibility, and (4) scanning performance. Test data taken in order to evaluate the interdependency of scan speed, noise and position are included. Shown also are results of tests for system stability, reproducibility, stray light and PMT settling time.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Astron. Microdensitometry Conf.; p 71-88
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Publication Date: 2006-02-14
    Description: The performance of densitometers used for photometric data reduction of high dynamic range electrographic plate material is analyzed. Densitometer repeatability is tested by comparing two scans of one plate. Internal densitometer errors are examined by constructing histograms of digitized densities and finding inoperative bits and differential nonlinearity in the analog to digital converter. Such problems appear common to the four densitometers used in this investigation and introduce systematic algorithm dependent errors in the results. Strategies to improve densitometer performance are suggested.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 45-58
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Various perturbations which occurred during the operation of a PDS 2020 GM microdensitometer are reviewed. The effects of elevated temperature, vibration, transient electrical noise, and photometric perturbations are briefly discussed. Sample astronomical results from the PDS 2020 GM unit are presented.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 97-106
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Publication Date: 2006-02-14
    Description: Digitizing flatfield images produces conditions in the Photometric Data System PDS which cause the measured density to drift by as much as .1 DN during a 10 minute interval. The drift occurs when the PDS, set up in equilibrium at fog level, subsequently scans a reasonably dense region for periods of longer than a few minutes. The drift is manifested primarily as a positive shift in density that is approximately the same for all densities. If the fog level is assumed to be in fact constant and is monitored during scans of flat fields, the PDS drift may be removed by subtracting the difference between the observed fog level and its assumed constant value for each pixel. This function is then smoothed and subtracted, as a function of scan line, from the measured density. The fog level is then adjusted to a standard value by adding a constant. The result is a flattened scan with PDS drift removed to the accuracy within which the fog level drift matches the drift at other levels.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Astron. Microdensitometry Conf.; p 59-69
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Publication Date: 2006-02-14
    Description: The photometric and positional accuracy of a microdensitometer is examined. A calibrating plate with different density areas available is used to determine photometric accuracy. Position accuracy is evaluated by multiple scans of sharp edges and analyzed statistically.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 35-43
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Many of the passive experiments flying on LDEF will be significantly enhanced if data are available postflight to indicate the temperature time histories of test materials and other specimens exposed in the experiments. The baseline LDEF approach was to provide postflight calculated temperature histories of experiment boundaries and solar flux data for the mission, which can in turn be used by each investigator to calculate the temperature time histories for critical experiment components. Without in-flight temperature measurements, a substantial uncertainty will exist in the calculated temperatures. The data measured by the themal measurement system (THERM) will significantly improve postflight knowledge of temperatures experienced by LDEF experiments. The THERM data will also be valuable in validating the LDEF thermal design concept and in providing better design data for experimenters on future LDEF missions. The objectives of this experiment are to determine the history of the interior average temperatures of the LDEF for the total orbital mission and to measure the temperatures of selected components and thermal boundary conditions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Long Duration Exposure Facility (LDEF); p 78-81
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Publication Date: 2011-08-18
    Description: New frequency calibration tables are required to keep abreast of the resolution attainable by currently available tunable lasers. One key to the generation of tables with requisite accuracy involves accurate heterodyne frequency measurements; another key consists of reliable fitting and analysis. Coordinated activity in NBS involves selection of suitable molecular calibration candidates, their frequency measurement and analysis, and dissemination of the results in the form of frequency calibration tables. Current status of these efforts is described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: A new extension to optogalvanic spectroscopy, in which electrons detached from negative ions formed in the discharge are observed as a function of incident laser wavelength, has been developed. The determination of the electron affinities of I(-) and Cl(-) atomic ions is described. The potential of the technique for studying the spectroscopy of molecular negative ions is also discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal de Physique (ISSN 0449-1947); 44; C7-461 t
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Publication Date: 2011-08-18
    Description: Previously cited in issue 5, p. 642, Accession no. A83-16486
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA Journal (ISSN 0001-1452); 22; 1115-112
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Publication Date: 2011-08-18
    Description: The design of a high spectral resolution, lambda/delta lambda being approximately 1200 IR, sounder capable of increasing the vertical resolution of atmospheric temperature profiles and achieving a rms accuracy of approximately 1.5 K is discussed. This sounder permits improved determination of meteorological parameters on cloudiness, surface temperature, and air-surface interactions. A set of channels from the high J lines in the R branch of the 4.3-micron CO2 band complemented by a larger set of window, humidity, and temperature channels in the 3.7-, 6.3-, 9-, and 15-micron regions is used. Design and simulation studies show that such a sounder is within the present state of the art.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 979-989
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Publication Date: 2011-08-18
    Description: This paper presents the conceptual design of an instrument, called the solar disk sextant, to be used in space to measure the shape and the size of the sun and their variations. The instrumental parameters required to produce sufficient sensitivity to address the problems of solar oblateness, solar pulsations, and global size changes of climatic importance are given.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 1235-123
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Publication Date: 2011-08-18
    Description: A holographic interferometer system has been installed in the NASA Ames 2- by 2-Foot Transonic Wind Tunnel. The system incorporates a modern 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described, as well as the integration of the system into the existing schlieren system. A two-plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models, the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Publication Date: 2011-08-18
    Description: Previously cited in issue 05, p. 643, Accession no. A83-16685
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA Journal (ISSN 0001-1452); 22; 557-559
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: A simple and inexpensive thermal diffusivity apparatus is described for measurement up to 1600 K. The novel features of apparatus include a light pipe, a long furnace, and a differential thermocouple. A low heat-load sample holder for clamping the sample in a vertical position is also described. The results of measurements on AXM-5Q graphite are reported.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments (ISSN 0034-6748); 55; 235-237
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Publication Date: 2011-08-19
    Description: A wave sensor, consisting of parallel, evenly spaced capacitance wires, whose output is the sum of the water surface deflections at the wires, has been built and tested in a wave tank. The probe output simulates Bragg scattering of electromagnetic waves from a water surface with waves; it can be used to simulate electromagnetic probing of the sea surface by radar. The study establishes that the wave probe, called the 'Harp' for short, will simulate Bragg scattering and that it can also be used to study nonlinear wave processes.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Atmospheric and Oceanic Technology (ISSN 0739-0572); 1; 358-371
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Publication Date: 2011-08-19
    Description: The standard balloon-borne radiosonde employed for synoptic meteorology provides vertical profiles of temperature, pressure, and humidity as a function of elapsed time. These parameters are used in the hypsometric equation to calculate the geopotential altitude at each sampling point during the balloon's flight. It is important that the vertical location information be accurate. The present investigation was conducted with the objective to evaluate the altitude determination accuracy of the standard radiosonde throughout the entire balloon profile. The tests included two other commercially available pressure sensors to see if they could provide improved accuracy in the stratosphere. The pressure-measuring performance of standard baroswitches, premium baroswitches, and hypsometers in balloon-borne sondes was correlated with tracking radars. It was found that the standard and premium baroswitches perform well up to about 25 km altitude, while hypsometers provide more reliable data above 25 km.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Atmospheric and Oceanic Technology (ISSN 0739-0572); 1; 321-327
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Publication Date: 2011-08-19
    Description: This paper presents an algorithm for azimuth correlation of synthetic aperture radar (SAR) data with extraordinarily large-range migration which cannot be accommodated by the existing frequency domain interpolation approach used in current Seasat SAR processing. A mathematical model is provided for the SAR range-correlated point-target response both in the spatial and frequency domains. A simple and efficient processing algorithm derived from the exact two-dimensional correlation algorithm is given. This algorithm enables azimuth correlation by two cascaded one-dimensional correlation steps. The first step is to transform the range-correlated SAR data into the frequency domain in azimuth, followed by a newly developed range convolution filter to correct the range-dispersed spectrum of the range-correlated point-target response (RCPTR). The second step is the frequency-domain range migration correction approach for the azimuth compression. Simulation results provided here indicate that this processing algorithm yields a satisfactory compressed impulse response for SAR data with large-range migration whereas previous methods were subject to a broadening of the impulse response along range.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Geoscience and Remote Sensing (ISSN 0196-2892); GE-22; 592-597
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Publication Date: 2011-08-18
    Description: A new two-wavelength lidar technique for remotely measuring the pressure profile using the trough absorption region between two strong lines in the oxygen A band is described. The theory of integrated vertical path, differential ranging, and horizontal-path pressure measurements is given, with methods to desensitize and correct for temperature effects. The properties of absorption troughs are described and shown to reduce errors due to laser frequency jitter by up to two orders of magnitude. A general analysis, including laser bandwidth effects, demonstrates that pressure measurements with an integrated-vertical-path technique are typically fifty times more accurate than with a differential ranging technique. Simulations show 0.1-0.3 percent accuracy for ground and Shuttle-based pressure-profile and surface-pressure experiments.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 22; 3759-377
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Publication Date: 2011-08-18
    Description: The laser-induced fluorescence (LIF) of green plants was evaluated as a means of remotely detecting plant stress and determining plant type. Corn and soybeans were used as representatives of monocots and dicots, respectively, in these studies. The fluorescence spectra of several plant pigments was excited with a nitrogen laser emitting at 337 nm. Intact leaves from corn and soybeans also fluoresced using the nitrogen laser. The two plant species exhibited fluorescence spectra which had three maxima in common at 440, 690, and 740 nm. However, the relative intensities of these maxima were distinctly different for the two species. Soybeans had an additional slight maxima at 525 nm. Potassium deficiency in corn caused an increase in fluorescence at 690 and 740 nm. Simulated water stress in soybeans resulted in increased fluorescence at 440, 525, 690, and 740 nm. The inhibition of photosynthesis in soybeans by 3-(3-4-dichlorophenyl)-1-1-dimethyl urea (DCMU) gave incresed fluorescence primarily at 690 and 740 nm. Chlorosis as occurring in senescent soybean leaves caused a decrease in fluorescence at 690 and 740 nm. These studies indicate that LIF measurements of plants offer the potential for remotely detecting certain types of stress condition and also for differentiating plant species.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 134-142
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Publication Date: 2011-08-18
    Description: Airborne laser-induced, depth-resolved water Raman backscatter is useful in the detection and mapping of water optical transmission variations. This test, together with other field experiments, has identified the need for additional field experiments to resolve the degree of the contribution to the depth-resolved, Raman-backscattered signal waveform that is due to (1) sea surface height or elevation probability density; (2) off-nadir laser beam angle relative to the mean sea surface; and (3) the Gelbstoff fluorescence background, and the analytical techniques required to remove it. When converted to along-track profiles, the waveforms obtained reveal cells of a decreased Raman backscatter superimposed on an overall trend of monotonically decreasing water column optical transmission.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 22; 3778-378
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Publication Date: 2011-08-19
    Description: The balloon-borne microwave limb sounder (BMLS) measures atmospheric thermal emission from millimeter wavelength spectral lines to determine vertical profiles of stratospheric species. The instrument flown to date operates at 205 GHz to measure ClO, O3, and H2O2. A 63 GHz radiometer will be added to test the technique for determining tangent point pressure from the MLS experiment on the upper atmosphere research satellite (UARS). Many additional species could also be measured by the BMLS. A radiometer at 270 GHz would provide measurements of HO2, NO2, HNO3, N2O, O-16O-18O-16, and HCN. With this addition, the BMLS can test the current theory of O3 photochemical balance in the upper stratosphere.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Quantitative Spectroscopy and Radiative Transfer (ISSN 0022-4073); 32; 407-433
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Publication Date: 2011-08-19
    Description: The present cryogenic blackbody reference, or 'cold load', for mm-wavelength radiation has an emissivity of more than 0.99 over a two-octave wavelength range and can be used as a calibrating standard for sensitive IR photometers. The transmittance spectrum obtained indicates that wave impedance and index do not vary significantly over the 80-360 GHz range.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Journal of Infrared and Millimeter Waves (ISSN 0195-9271); 5; 1507-151
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-19
    Description: This paper discusses the measurement and comparison of particle size and velocity measurements in sprays. The general nature of sprays and the development of standard, consistent research sprays are described. The instruments considered in this paper are: pulsed laser photography, holography, television, and cinematography; laser anemometry and interferometry using visibility, peak amplitude, and intensity ratioing; and laser diffraction. Calibration is by graticule, reticle, powders with known size distributions in liquid cells, monosize sprays, and, eventually, standard sprays. Statistical analyses including spatial and temporal long-time averaging as well as high-frequency response time histories with conditional sampling are examined. Previous attempts at comparing instruments, the making of simultaneous or consecutive measurements with similar types and different types of imaging, interferometric, and diffraction instruments are reviewed. A program of calibration and experiments for comparing and assessing different instruments is presented.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Publication Date: 2011-08-19
    Description: Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluoresence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the short-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 4076-408
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Publication Date: 2011-08-19
    Description: The response characteristics of laser diffraction particle sizing instruments were studied theoretically and experimentally. In particular, the extent of optical sample volume and the effects of receiving lens properties were investigated in detail. The experimental work was performed with a particle size analyzer using a calibration reticle containing a two-dimensional array of opaque circular disks on a glass substrate. The calibration slide simulated the forward-scattering characteristics of a Rosin-Rammler droplet size distribution. The reticle was analyzed with collection lenses of 63 mm, 100 mm, and 300 mm focal lengths using scattering inversion software that determined best-fit Rosin-Rammler size distribution parameters. The data differed from the predicted response for the reticle by about 10 percent. A set of calibration factor for the detector elements was determined that corrected for the nonideal response of the instrument. The response of the instrument was also measured as a function of reticle position, and the results confirmed a theoretical optical sample volume model presented here.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optical Engineering (ISSN 0091-3286); 23; 610-619
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Publication Date: 2011-08-18
    Description: Eight dual channel microwave radiometers were constructed as a research and development effort for the Crustal Dynamics Project and the Deep Space Network. These instruments, known as water vapor radiometers, are primarily intended to demonstrate that the variable path delay imposed by atmospheric water vapor can be calibrated in microwave tracking and distance measuring systems but could also be used in other applications involving moist air meteorology and propagation studies. They are being deployed to various stations and observatories that participate in Very Long Baseline Interferometry experiments. The development history of these instruments are reviewed, the theory of operation and overall design considerations are outlined, and the instrumental parameters and performance characteristics are described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommun. and Data Acquisition Rept.; p 1-19
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: The design and performance of the high-density digital recorder (HDDR) developed for use at the NASA centers (KSC, JSC, and GSFC) and at the JPL to store and retrieve 50-Mb/s PCM data streams from the Spacelab experiments are reported. The recording reproduction, and transport requirements are reviewed; and the design solutions adopted in the final version of the HDDR are described, incuding three-position-modulation and Y-phase encoding, microprocessor-controlled automatic bit synchronization and equalization, cyclic-redundancy-check error detection and correction, clock regeneration, data and clock variations, tape-speed control, and EEE-488 remote control. Reliable performance, with bit error rates 1 in 10 to the 10th forward and 1 in 10 to the 9th reverse or better and packing density up to 50 percent greater than that obtainable using conventional codes, is reported after 1.5 years of service.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Publication Date: 2011-08-18
    Description: An analysis method for Fourier transform spectroscopy is summarized with applications to various types of distortion in atmospheric absorption spectra. This analysis method includes the fast Fourier transform method for simulating the interferometric spectrum and the nonlinear least-squares method for retrieving the information from a measured spectrum. It is shown that spectral distortions can be simulated quite well and that the correct information can be retrieved from a distorted spectrum by this analysis technique.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 2604-261
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Publication Date: 2011-08-18
    Description: Sampling generally causes the response of a digital imaging system to be locally shift-variant and not directly amenable to Modulation Transfer Function (MTF) analysis. However, this paper demonstrates that a meaningful system response can be calculated by averaging over an ensemble of point-source system inputs to yield an MTF which accounts for the combined effects of image formation, sampling, and image reconstruction. As an illustration, the MTF of the Landsat MSS system is analyzed to reveal an average effective instantaneous field of view which is significantly larger than the commonly accepted value, particularly in the along-track direction where undersampling contributes markedly to an MTF reduction and resultant increase in image blur.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 2572-258
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Publication Date: 2011-08-18
    Description: Tests have been made of a nondispersive spectroscopic X-ray detector which operates by measuring the temperature rise following absorption of a single photon. Thermal pulses from 6-keV X-rays have been observed, and the different amplitudes resulting from Mn K-alpha and K-beta events have been resolved. This device was assembled to make quantitative tests of theoretical calculations of the properties of such detectors, and its high heat capacity does not allow it to attain the very high resolution predicted for detectors made by more sophisticated, but still straightforward, techniques. Both the measured resolution of 270-eV full width at half maximum and the absolute amplitude of the response are consistent with predictions. Nonthermal effects in the thermistor limit the precision of this comparison to about 30 percent.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Applied Physics (ISSN 0021-8979); 56; 1263-126
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Publication Date: 2011-08-18
    Description: Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Applied Physics (ISSN 0021-8979); 56; 1257-126
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: A large-aperture interferometer was devised by adding a local-reference-beam-generating optical system to a schlieren system. Two versions of the interferometer are demonstrated, one employing 12.7 cm (5 in.) diameter schlieren optics, the other employing 30.48 cm (12 in.) diameter parabolic mirrors in an off-axis system. In the latter configuration a cylindrical lens is introduced near the light source to correct for astigmatism. A zone plate is a satisfactory decollimating element in the reference-beam arm of the interferometer. Attempts to increase the flux and uniformity of irradiance in the reference beam by using a diffuser are discussed. Previously announced in STAR as N83-13979
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 1467-147
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Publication Date: 2011-08-18
    Description: A pulsed CO2 lidar was used to study statistical properties of signal returns from various rough surfaces at distances near 2 km. These included natural in situ topographic materials as well as man-made hard targets. Three lidar configurations were used: heterodyne detection with single temporal mode transmitter pulses, and direct detection with single and multiple temporal mode pulses. The significant differences in signal return statistics, due largely to speckle effects, are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 1412-141
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Publication Date: 2011-08-18
    Description: This paper illustrates a method for calibrating seven-hole probes to measure local total and static pressures and relative flow angles of up to 70 degrees in subsonic compressible flows. The method of Latin Squares was used to statistically sample a large and otherwise unmanageable data set, thereby reducing to a minimum the number of data points required to construct a polynomial curve fit to the data. Calibration produces three-variable third order polynomials which permit all of the desired flow properties to be found explicitly from probe measured pressures. This method determines the flow angles to within 2 degrees and Mach number to within 0.04 with 95 percent certainty.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Experiments in Fluids (ISSN 0723-4864); 2; 2, 19; 95-103
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Publication Date: 2011-08-18
    Description: The stratospheric mixing ratio of nitric oxide at an altitude of 36 km has been measured using a balloon-borne tunable diode laser (TDL) instrument operating in the 5.2-micron wavelength region. Currently the instrument operates with two TDLs, and the capability exists to measure four stratospheric species simultaneously: NO, NO2, O3, and H2O. During the NO measurements reported here, the second TDL operating near 6.2 microns was used to monitor water vapor concentration in the vicinity of the gondola by observing the 1889.57 per cm line absorption in the reference channel path length (1 m).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 1140-114
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Publication Date: 2011-08-18
    Description: To support the development of advanced infrared remote sensing instrumentation using line and area arrays, a test facility has been developed to characterize the detectors. The necessary performance characteristics of the facility were defined by considering current and projected requirements for detector testing. The completed facility provides the desired level of detector testing capability as well as providing ease of human interaction.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Publication Date: 2011-08-18
    Description: Two comparisons of available specular infrared measurements using identical or very similar coatings reveal that specular BRDF (bidirectional reflectance distribution function) measurements of rough coatings are comparable but that simple measured reflectances are not. This is seen as indicating that the diffuse component of the measured specular reflectance is significantly larger than that of the specular component. It is noted that the diffuse component of the measurement is a convolution of the intrinsic directional reflectivity of the surface with the instrument function and that because the value of that function increases at the wavelengths under consideration, the diffuse component is larger than would otherwise be expected. The BRDF normalization is found to cause a primitive deconvolution of the instrument function and to produce a quantity that is approximately equal to the mean intrinsic directional reflectivity very near the specular direction. The analysis and comparison of data reveal that nonspecular BRDF measurements at angles well outside the instrument function can be calibrated as well by an image of the source upon the detector as by reference to a known surface.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Publication Date: 2011-08-18
    Description: An analysis is presented of the accuracy of infrared differential absorption lidar (DIAL) measurements of trace constituents in the atmosphere. Expressions are derived for the signal-to-noise ratios applicable in the detection of a signal from a scattering cell for the cases of single-detection heterodyne detection and direct detection. Results of computer simulations of the expectation value of the measured return for various measurement conditions are presented which illustrate the sensitivities of plume measurements for horizontal range-resolved and vertical content measurements of NH3 in heterodyne and direct detection. Advantages for long-range measurements of the use of rare isotope laser frequencies, tuning by collision broadening, and closely spaced on and off frequencies are pointed out.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: Several examples of applications of coherent CO2 Doppler lidar systems are summarized to illustrate the potential of these systems. The applications discussed include the use of continuous-wave systems for detecting and tracking aircraft wake vortices, transverse velocity measurements, and measurements of mass flow rates of high stack emissions. The use of pulsed coherent lidars is illustrated by applications involving the measurement of thunderstorm gust fronts, the measurement of wind profiles, and clear air turbulence detection. Following a summary of previous efforts, some current programs are reviewed. These include investigations into two-dimensional wind field measurements, atmospheric backscatter measurements, transverse velocity measurements, and the feasibility of space operations.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: The present investigation represents a part of a NASA program which is concerned with a study regarding the seriousness of man-made stratospheric ozone depletion. Such a depletion could possibly be caused by exhaust gases of aircraft at high altitudes or the release of chlorofluorocarbons into the lower atmosphere. A balloon-borne optical radar system was employed to conduct ozone measurements in the altitude region from 21 to 36 km and hydroxyl radical measurements in the region from 33 to 36 km. The hydroxyl radical was determined by making use of a procedure which is based on fluorescence induced by laser radiation. The technique of differential absorption lidar (DIAL) was used to measure ozone. According to this technique, two wavelengths are transmitted simultaneously and their backscattered intensities are measured. the obtained results show that optical radar represents an effective tool for stratospheric investigations.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Publication Date: 2011-08-18
    Description: The improvement in measurement uncertainty brought about by the averaging of increasing numbers of pulse return signals in both heterodyne- and direct-detection lidar systems is investigated. A theoretical analysis is presented which shows the standard deviation of the mean measurement to decrease as the inverse square root of the number of measurements, except in the presence of temporal correlation. Experimental measurements based on a dual-hybrid-TEA CO2 laser differential absorption lidar system are reported which demonstrate that the actual reduction in the standard deviation of the mean in both heterodyne- and direct-detection systems is much slower than the inverse square-root dependence predicted for uncorrelated signals, but is in agreement with predictions in the event of temporal correlation. Results thus favor the use of direct detection at relatively short range where the lower limit of the standard deviation of the mean is about 2 percent, but advantages of heterodyne detection at longer ranges are noted.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Publication Date: 2011-08-18
    Description: The present investigation is concerned with differential absorption lidar techniques for remotely measuring the atmospheric temperature and pressure profile, surface pressure, and cloud top pressure-height. The procedure used in determining the pressure is based on the conduction of high-resolution measurements of absorption in the wings of lines in the oxygen A band. Absorption with respect to these areas is highly pressure sensitive in connection with the mechanism of collisional line broadening. The method of temperature measurement utilizes a determination of the absorption at the center of a selected line in the oxygen A band which originates from a quantum state with high ground state energy.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Publication Date: 2011-08-18
    Description: The present investigation is concerned with the application of a pressure modulated radiometer (PMR) to the remote sensing of trace amounts of gases in the atmospheres as well as to the direct measurement of upper atmospheric winds. The PMR operates as a gas correlation spectrometer. Compared to conventional gas correlation parameters, it has some advantages which are related to greater versatility and the employment of a simpler method for maintaining electrical/optical balance. The PMR has a high sensitivity in connection with its essentially very high effective resolution. It represents a passive system and emits no radiation. A PMR is flown on Nimbus 6 which was launched in 1975. The instrument has also been used on the Nimbus 7 satellite and the Tiros N satellite.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Publication Date: 2011-08-18
    Description: The present investigation is concerned with an optical radar instrument which has been developed for airborne remote sensing of atmospheric trace species at infrared wavelengths. The instrument makes use of compact, pulsed carbon dioxide lasers. It was designed for conducting differential absorption lidar (DIAL) measurements. The backscatter of laser pulse energy from the ocean and terrain surface is utilized to determine trace species column content. The instrument, which is carried by the NASA P3 aircraft, is used in a flight test program started in July 1981. The results obtained with the instrument in this program are discussed, taking into account ocean surface backscatter statistics, the ratio of ocean to terrain backscatter, the dual-wavelength correlation coefficient, the dual-wavelength cross-covariance, and the dependence of un-correlated noise variance on the mean backscatter signal.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Publication Date: 2011-08-18
    Description: An instrument has been designed for the measurement of stratospheric trace species which utilizes tunable infrared diode lasers as sources for sensitive in situ absorption spectroscopy in selected wavelength regions. This instrument, the Balloon-Borne Laser In Situ Sensor (BLISS), is a high-resolution absorption spectrometer designed to provide measurements of the concentrations of stratospheric species and their diurnal variations. The instrument employs second-harmonic detection of the absorption of tunable diode laser (TDL) radiation (3-30 microns) in a 1 km path length defined by a retroreflector lowered 0.5 km below the BLISS gondola. Retroreflector tracking under microprocessor control is obtained using a He-Ne laser and coaligned TV camera with CID imaging. Simultaneous measurements of molecular species in the 20-40 km altitude range will be performed using four TDLs, with the predicted minimum-detectable mixing ratio at 30 km being typically less than or equal to 0.1 ppbv.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 22; Sept. 1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Publication Date: 2011-08-18
    Description: New developments in the areas of narrowband tunable excimer lasers, high-resolution high-rejection optical filters, and wavelength measurement devices are considered for application to the remote sensing of atmospheric hydroxyl radicals. The conclusion is that an increase in the SNR of 10,000 could readily be gained through the use of these new devices. Also, considerable reductions in size and electrical energy consumption could be realized.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 22; Sept. 1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Publication Date: 2011-08-18
    Description: A lidar instrument based on pulsed frequency-doubled carbon-dioxide lasers has been used at 4.88 microns for remote sensing of atmospheric carbon dioxide. A tunable-diode laser spectrometer provided the high-resolution spectroscopic data on carbon-dioxide line strength and line broadening needed for an accurate differential absorption measurement. Initial field measurements are presented, and instrument improvements necessary for accurate carbon dioxide measurement are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 22; Sept. 1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Publication Date: 2011-08-18
    Description: A surface acoustic wave (SAW) sensor constructed from single-mode fiber-optic components is described. An analysis of reciprocal and nonreciprocal modes of operation of the sensor is presented. Results from measurements on a variety of SAW devices illustrate the use of the sensor. The amplitude sensitivity is 0.0003 A for an integration time of 0.1 s.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Lightwave Technology (ISSN 0733-8724); LT-1; June 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Publication Date: 2011-08-18
    Description: Methods for using a combination of computer-generated color graphics and image processing techniques to display a large data base of environment information are described. The data source can be either field data or mathematical models, reduced to summary statistics that characterize the data field as a whole. Sharp gradients are plotted into contour plots, which can also feature shades, degree of brightness, and saturation levels for fine-tuning the image. The basic concepts of digital image processing are reviewed, including location of the pixels, intensity mapping operations, pseudocolor enhancements, neighborhood averaging, and smoothing. Sample applications are presented in terms of emissions and air quality distributions over the south coast air basin of southern California.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Environmental Science and Technology (ISSN 0013-936X); 17; Feb. 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Publication Date: 2011-08-18
    Description: A method is described for monitoring the changing thickness of a thin oil film subject to an aerodynamic shear stress using two focused laser beams. The measurement is then simply analyzed in terms of the surface skin friction of the flow. The analysis includes the effects of arbitrarily large pressure and skin friction gradients, gravity, and time varying oil temperature. It may also be applied to three dimensional flows with unknown direction. Applications are presented for a variety of flows, including two dimensional flows, three dimensional swirling flows, separated flow, supersonic high Reynolds number flows, and delta wing vortical flows. Previously announced in STAR as N83-12393
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Experiments in Fluids (ISSN 0723-4864); 1; 1, 19; 1983
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Publication Date: 2011-08-18
    Description: An improved condensation nucleus counter (CNC) for use in the stratosphere is described. The University of Minnesota CNC (UMCNC) has a sequential saturator and condenser and uses n-butyl alcohol as the working fluid. The use of a coaxial saturator flow, with aerosol in the center and filtered, alcohol-laden air around it, speeds the response of this instrument and improves its stability as pressure changes. The counting efficiency has been studied as a function of particle size and pressure. The UMCNC provides an accurate measure of submicron aerosol concentration as long as the number distribution is not dominated by sub-0.02 micron diameter aerosol. The response of the UMCNC is compared with that of other stratospheric condensation nucleus counters, and the results of a (near) comparison with a balloon-borne condensation nucleus counter are presented. The UMCNC has operated 14 times on a NASA U-2 aircraft at altitudes from 8 to 21.5 km.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 88; Aug. 20
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: Using data available for small rotameters that use spherical floats in gas flow, a linear relationship is derived. It is noted that the relationship provides a good fit for variable volumetric flow, density, and viscosity at constant flow height. With low Reynolds numbers (Re being less than 1), the product of the variable volumetric flow and the viscosity becomes constant; at high Reynolds numbers (Re being greater than 2000), the product of the variable volumetric flow and the square root of the density becomes constant. It is pointed out that the equation given here can be used to obtain an indirect calibration with any gas of known density and viscosity. The constancy of the product of the variable volumetric flow and viscosity at low variable volumetric flows is seen as suggesting the development of simple, inexpensive gas viscometers using rotameter technology.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: I & EC-Industrial and Engineering Chemistry, Fundamentals (ISSN 0196-4313); 22; 2, 19; 1983
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Publication Date: 2011-08-18
    Description: The Airborne Laser Ranging System is a proposed multibeam short pulse laser ranging system on board an aircraft. It simultaneously measures the distances between the aircraft and six laser retroreflectors (targets) deployed on the earth's surface. Depending on the host aircraft and terrain characteristics, the system can interrogate hundreds of targets distributed over an area as large as 60,000 sq. km in a matter of hours. Potentially, a total of 1.3 million individual range measurements can be made in a 6 hr flight. The precision of these range measurements is approximately 1 cm. These measurements are then used in a procedure which is basically an extension of trilateration techniques to derive the intersite vector between the laser ground targets. By repeating the estimation of the intersite vector, strain and strain rate errors can be estimated. These quantities are essential for crustal dynamic studies which include determination and monitoring of regional strain in the vicinity of active fault zones, land subsidence, and edifice building preceding volcanic eruptions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Bulletin Geodesique (ISSN 0007-4632); 57; 2, 19; 1983
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Publication Date: 2011-08-18
    Description: A simplified version of moire deflectometry for flow visualization is presented. The modification comprises replacement of the second grating, the ground glass screen, and the camera with a plate film holder to obtain a shadow picture. Postanalysis proceeds by placing a grid transparency of the same periodicity of the remaining glass grating on the negative for projection viewing. The rotational angle between the grating and the plate alters the moire fringe periodicity. Use of the method in studying flows is predicted to reveal weak density gradient areas and shocks.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 22; Mar. 1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Publication Date: 2011-08-18
    Description: Several important aspects of lidar are discussed, which pertain to a system analysis of the applicability of certain types of lidar to specific measurement objectives. The differential absorption lidar (DIAL) technique is emphasized. A brief treatment of the DIAL technique is followed by a discussion of the comparison of DIAL with other lidar measurement techniques. Sensitivity expressions are presented for DIAL with either direct or coherent (heterodyne) detection systems. A treatment of the fundamental similarities and differences in using the UV and IR spectral regions for species measurements, such as backscattering properties, spectral characteristics of the absorbing species, and factors relevant to the optimization of the DIAL measurement accuracy, is also included. Finally, results obtained from an existing ground-based DIAL system used to measure water vapor profiles are briefly discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: Recent developments in the area of wide-bandwidth infrared detectors, both for direct and heterodyne detection, are reviewed with emphasis on the differences and tradeoffs between photodiodes and photoconductors. In the direct-detection mode, where amplifier noise is an important consideration, the state-of-the-art detection noise equivalent power is approximated by 500 (B/10 MHz) pW. At short wavelengths (less than 1.7 micron), avalanche photodiodes offer superior performance, with a detection noise equivalent power of about 50 (B/10 MHz) pW. In heterodyne operation, near-ideal sensitivities of about 0.3 (B/10 MHz) pW have been achieved with 77K photodiodes. At 10 microns, HgCdTe photoconductors offer very good heterodyne performance at elevated temperatures: 2 (B/10 MHz) pW at 195 K and potentially 3 (B/10 MHz) pW at 250 K.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Publication Date: 2011-08-18
    Description: Multispectral scanner and thematic mapper (TM) data from Landsat satellites are discussed in terms of the perceived 'simultaineity' of the images, which are obtained by scanning techniques. Scanning the scenes ensures that the data points of the images are actually sequential, even if the scan is performed at rates that are fast relative to the motion of the spacecraft. The last datum gathered by the MSS is, in fact, taken 29 sec after the first, witih a 56 m distance being present between pixels. The spacing in uneven from band to band on the TM and analyses of the data to produce an image requires consideration of nonfixed time relationships for different locations on the scan within and among the bands. Additionally, corrective measures must be taken to compensate for instrument jitter and attitude changes.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Journal of Remote Sensing (ISSN 0143-1161); 4; July-Sep
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Publication Date: 2011-08-18
    Description: A common problem associated with X-ray imaging using coded apertures is the reconstruction of low-intensity extended objects. In the decoding of such objects, the overlapping images from the multiple pinholes give rise to noise cross talk and, in many cases, also to signal cross talk. In this paper, an alternate approach is proposed based on the principle used in an earlier (Yin et al., 1980) laboratory device for the real-time viewing of X-ray objects. It is shown that with this approach, the nonoverlapping redundant array, the sidelobes in the point spread function are not eliminated but merely displaced through a suitable choice of geometry. In this manner, the sidelobes no longer contribute to the background in the vicinity of a reconstructed image, and both signal and noise cross talks are completely eliminated. It may now be possible to reconstruct extended X-ray objects in 3-D by simple optical correlation and tomographically by a computer.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 22; July 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Publication Date: 2011-08-18
    Description: The application of the resonant Doppler velocimeter (RDV) for obtaining the mean velocity, temperature, and pressure measurements and flow-field visualization in a supersonic free nitrogen jet is reported. This method utilizes laser-induced fluorescence to determine the spectral absorption of an atomic or molecular species seeded into the flow. A narrow linewidth tunable laser is directed into the flow and the total fluorescence from any point is obtained as the laser is tuned. The velocity of the flow is obtained from the Doppler shifted absorption frequency, and the temperature and pressure of the gas are determined from line broadening measurements. Results are presented for the use of this technique to determine the velocity, temperature, and pressure of the flow of sodium atoms seeded into a supersonic nitrogen jet. It is concluded that the visible signal is sufficiently intense for spatially resolved flow visualization purposes.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Physics Letters (ISSN 0003-6951); 43; July 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Publication Date: 2011-08-18
    Description: Previously cited in issue 08, p. 1219, Accession no. A82-22070
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: (ISSN 0001-1452)
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Publication Date: 2011-08-18
    Description: A small, battery-operated X-ray generator has been developed to be used as part of a small-format fluoroscopic system, the Lixiscope (Low Intensity X-ray Imaging Scope). The X-ray generator consists of a grounded rod-anode X-ray tube with a 0.2 mm focal spot and a specially designed, battery-operated, 0 to -80 kV high-voltge supply. Total power consumption is about 10 W. The fine focal spot, in conjunction with the continuously variable X-ray intensity and spectral distribution, helps to extend both the versatility and the performance of the Lixiscope toward a much wider range of terrestrial and spacecraft applications. The complete fluoroscopic system is described, and some examples of possible applications are shown.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Materials Evaluation (ISSN 0025-5327); 41; June 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: A fast Fourier transform technique is given for the simulation of those distortion effects in the instrument line shape of the interferometric spectrum that are due to errors in the measured interferogram. The technique is applied to analyses of atmospheric absorption spectra and laboratory spectra. It is shown that the nonlinear least squares method can retrieve the correct information from the distorted spectrum. Analyses of HF absorption spectra obtained in a laboratory and solar CO absorption spectra gathered by a balloon-borne interferometer indicate that the retrieved amount of absorbing gas is less than the correct value in most cases, if the interferogram distortion effects are not included in the analysis.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 22; Mar. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Publication Date: 2016-06-07
    Description: To facilitate the navigation of spacecraft to the outer planets, Jupiter and beyond, the JPL-NASA Deep Space Network (DSN) has implemented three ensembles of atomic clocks at widely separated locations. These clocks must be maintained, synchronized, to with a few parts in 10 to the 13th power of each other and, the entire group must be maintained, to a lesser degree, in synchronism with Coordinated Universal Time (UTC)NBS/USNO. Over the last 1 1/2 years the DSN has been using Global Positioning Satellites (GPS) and Very Long Baseline Interferometry (VLBI) technology to perform these critical Frequency and Time (F&T) synchronization tasks. A year of F&T synchronization data collected from the intercomparison of 3 sets of cesium and hydrogen maser driven clock ensembles through the use of GPS and VLBI techniques are covered. Also covered, are some of the problems met and limitations of these two techniques at their present level of technology.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 447-465
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2016-06-07
    Description: The Fluids Experiment Apparatus FEA is a modular zero gravity chemistry/physics laboratory to support fundamental space processing research. It can be used to conduct basic and applied process or product experiments in general liquid chemistry, crystal growth, fluid mechanics, thermodynamics, and cell culturing. The various FEA subsystems are readily configured to perform a wide range of investigations.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center 2nd Symp. on Space Industrialization; p 333-341
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Publication Date: 2016-06-07
    Description: A demonstration test of burner liner strain measurements using resistance strain gages as well as a feasibility test of an optical speckle technique for strain measurement are presented. The strain gage results are reported. Ten Kanthal A-1 wire strain gages were used for low cycle fatigue strain measurements to 950 K and .002 apparent strain on a JT12D burner can in a high pressure (10 atmospheres) burner test. The procedure for use of the strain gages involved extensive precalibration and postcalibration to correct for cooling rate dependence, drift, and temperature effects. Results were repeatable within + or - .0002 to .0006 strain, with best results during fast decels from 950 K. The results agreed with analytical prediction based on an axisymmetric burner model, and results indicated a non-uniform circumferential distribution of axial strain, suggesting temperature streaking.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Lewis Research Center Turbine Engine Hot Section Technology, 1984; 16 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Publication Date: 2016-06-07
    Description: Laser anemometers are being developed for use in the turbine facilities at Lewis that are involved in the Turbine Engine Hot Section Technology Program. The status of the program is given along with some results accomplished since 1983.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Turbine Engine Hot Section Technology, 1984; 11 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Publication Date: 2016-06-07
    Description: The TRAK Systems' GOES Satellite Synchronized Time Code Generator is described. TRAK Systems has developed this timing instrument to supply improved accuracy over most existing GOES receiver clocks. A classical time code generator is integrated with a GOES receiver.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 411-418
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Publication Date: 2016-06-07
    Description: Work on an innovative design for miniature rubidium frequency standards has reached the pre-production demonstration stage at Litton Guidance and Control Systems. Pre-production units were built and tested under contract to the Rome Air Development Center of the U.S. Air Force Systems Command. The units, which are designed for use in tactical military applications, feature fast warm-up, low power consumption, and vibration insensitivity. The output stability under vibration is maintained without the need for external shock-mounts. The design objectives and test results are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 143-155
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Publication Date: 2016-06-07
    Description: The on-oribt operational performance of the frequency standards on the Global Positioning System (GPS) 1 to 10 NAVSTAR satellites are discussed. The history of the Rb frequency standards showing the improvements incorporated at various stages of the program and the corresponding results are presented. Also presented is the operational history of the NAVSTAR cesium frequency standards. The frequency standards configuration data presented covers the chronology of events from the concept validation satellites, NAVSTAR 1 to 10, starting in 1978 to the present, including the configurations of clocks to be used on the GPS Production Program. Data are presented showing the results of long-term laboratory testing of a production Rb frequency standard with the necessary data taken to calculate Delta F, drift, time error, and Allan variance.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 127-141
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Publication Date: 2016-06-07
    Description: The mechanisms of the instrument pointing system (IPS) are described. Particular emphasis is placed on the actuators which are necessary for operating the IPS. The actuators are described as follows: (1) two linear actuators that clamp the gimbals down during ascent and descent; (2) two linear actuators that attach the payload to the IPS during the mission, and release it into the payload clamps; (3) one rotational actuator that opens and closes the payload clamps; and (4) three identical drive units that represent the three orthogonal gimbal axes and are the prime movers for pointing. Design features, manufacturing problems, test performance, and results are presented.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center The 18th Aerospace Mech. Symp.; p 15-28
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Publication Date: 2014-09-27
    Description: In order to utilize the quantitative accuracy built into the Thematic Mapper effectively, more attention must be paid to calibration before launch, changes of calibration before launch, changes of calibration with time in orbit, and atmospheric interference with the measurements, especially in the 450 to 520 nanometer band. Recent experience with the Coastal Zone Color Scanner (CZCS) program has led to procedures wherein Rayleigh correction factors can be generated utilizing simultaneous surface truth data that empirically give correct upwelled surface radiances. Instruments, such as the CZCS, have shown that calibration changes first, and to the largest degree, at the shorter wave lengths, with lesser changes as wave length increases. These techniques are utilized to calculate a Rayleigh correction factor that, together with geometric terms, will give an accurate correction for this portion of the atmospheric contribution to the signal.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center LANDSAT-4 Sci. Invest. Summ., Including Dec. 1983 Workshop Results, Vol. 2; p 20
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Publication Date: 2014-09-17
    Description: Relative spectral response data for the LANDSAT-4 and LANDSAT-4 backup multispectral scanner subsystems (MSS), the protoflight and flight models are presented and compared to similar data for the LANDSAT 1, 2 and 3 scanners. Channel (six channels per band) outputs for soil and soybean targets were simulated and compared within each band and between scanners. The principal differences between the spectral responses of the LANDSAT-4 scanners and previous scanners are discussed. The simulated LANDSAT-4 scanner outputs were 3 to 10 percent lower in the red band and 3 to 11 percent higher in the first near-IR band than previous scanners for the soybeans targets. The LANDSAT-4 scanners were generally more uniform from channel to channel within bands than previous scanners. In the upper-band edge of the red band of the protoflight scanner, one channel was markedly different (12 nm) from the rest. For a soybeans target, this nonuniformity resulted in a within-band difference of 6.2 percent in simulated outputs between channels.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: LANDSAT-4 Sci. Invest. Summ., Including Dec. 1983 Workshop Results, Vol. 2; p 73-75
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Publication Date: 2014-09-10
    Description: Eight water vapor radiometers (WVRs) were constructed as research and development tools to support the Advanced System Programs in the Deep Space Network and the Crustal Dynamics Project. These instruments are intended to operate at the stations of the Deep Space Network (DSN), various radio observatories, and obile facilities that participate in very long baseline interferometric (VLBI) experiments. It is expected that the WVRs will operate in a wide range of meteorological conditions. Several algorithms are discussed that are used to estimate the line-of-sight path delay due to water vapor and columnar liquid water rom the observed microwave brightness temperatures provided by the WVRs. In particular, systematic effects due to site and seasonal variations are examined. The accuracy of the estimation as indicated by a simulation calculation is approximately 0.3 cm for a noiseless WVR in clear and moderately cloudy weather. With a realistic noise model of WVR behavior, the inversion accuracy is approximately 0.6 cm.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommun. and Data Acquisiton Rept.; p 12-26
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Publication Date: 2014-09-11
    Description: Efforts directed toward interfacing an LSI II bus of a PDP 11/23 desktop computer with a quadrupole mass spectrometer for the purpose of providing a convenient system whereby mass spectral data, of the products of thermal decomposition, may be rapidly acquired and processed under programmed conditions are described. The versatility and operations of the quadrupole mass spectrometer are discussed as well as the procedure for configurating the LSI II bus of the PDP 11/23 desktop computer for interfacing with the quadrupole mass spectrometer system. Data from the mass filter and other units of the spectrometer are digitally transferred to the computer whereupon mass spectral data and related data are generated.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Alabama Univ. Res. Rept.: 1983 NASA(ASEE Summer Faculty Fellowship Program; 26 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Publication Date: 2014-09-10
    Description: A water vapor radiometer is used to estimate the columnar content of atmospheric water vapor or equivalently the line-of-sight path delay due to water vapor. Two measurement channels are used in order to separate the effects of the liquid and vapor phases of water. The efficiency of the path delay or columnar vapor estimate is dependent on the choice of on-line frequency channel. Previous analysis of this problem has suggested frequencies from 20.3 to 21 GHz. The frequency that yields the minimum error in the inversion algorithm is shown here to be both site and season dependent. Hence, the concept of an optimum frequency must represent an averaging process over the entire range of meteorological conditions that is expected. For a range of sites and condition representing a cross section of the continental United States the optimum on-line frequency seems to be 20.6 GHz.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommun. and Data Acquisition Rept.; p 1-11
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Publication Date: 2014-09-11
    Description: Time interval error (TIE) is the error of a clock at time t after it is synchronized and syntonized at time zero. Previous simulations of Flicker FM noise yielded a mean-square TIE proportional to sq t. It is shown that the order of growth is actually sq t log t. The earlier sq t result is explained and a modified version of the Barnes-Jarvis simulation algorithm is given.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommun. and Data Acquisition Rept.; p 126-135
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗