ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Other Sources  (554)
  • INSTRUMENTATION AND PHOTOGRAPHY  (554)
  • 2000-2004
  • 1980-1984  (554)
  • 1975-1979
  • 1960-1964
  • 1925-1929
  • 2000
  • 1984  (306)
  • 1981  (248)
  • 1
    Publication Date: 2006-02-14
    Description: The use of laser holography for measuring the distortion of antennas under space simulation conditions is described. The subject is the so-called double exposure procedure which allows to measure the distortion in the order of 1 to 30/micrometers + or - 0.5 per hologramme of an area of 4 m diameter max. The method of holography takes into account the constraints of the space simulation facility. The test method, the test set up and the constraints by the space simulation facility are described. The results of the performed tests are presented and compared with the theoretical predictions. The test on the K-Band Antenna e.g., showed a distortion of approximately 140/micrometers + or - 5/micrometers measured during the cool down from -10 C to -120 C.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center 13th Space Simulation Conf.; p 309-319
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2006-02-14
    Description: Conventional schemes for digitizing large volumes of photographic data are far too costly and time consuming to encourage the undertaking of the ambitious projects using traditional technology. There is a distinct need for fast digitizing systems such as could be derived from development of large format, optically multiplexed CCD systems designed to address these problems. The use of CCD chips for data handling and the capability of using polaroids in the optical path for reduced light scattering are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 419-427
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Parameters of the UK 1.2 meter Schmidt telescope are described. Plates taken with this instrument are in two categories, those for systematic sky surveys and those taken at the request of research users. A collaborative project with the European Southern Observatory was undertaken to obtain a two-color survey of the sky south of -20 deg declination to complement the Palomar survey. A near infrared survey of the Galactic Plane and the Megallanic Clouds is being done. The area south of -20 deg and the zone between 0 deg and -15 deg are also being surveyed. Pending a decision on survey parameters, all available A quality prism plates are being retained to form a basis for systematic survey. Nearly half the plates taken on a service basis for the UK astronomical community are to fulfill nonsurvey requests. Plates taken for surveys which are not of A grade quality are also made available for research purposes.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 379-385
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2006-02-14
    Description: Some software facilities used mainly for information retrieval and analysis at the Padova-Asiago Observatory are discussed. These facilities help guest and resident astronomers to make easier the preparation of plate measurements. The problems connected with the creation, use and management of a data base in a scientific (astronomical) environment are reviewed on the basis of the experience gathered during the last three years. The development plan of the user session environment and its possible applications in a computer network are briefly sketched.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 361-369
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: A 256 diode-array will be installed as detector on the ESO OPTRONICS S-3000 measuring machine in order to increase the acquisition rate. A high intensity LED will be used as light source in a pulse mode. The data will be stored on a random access mass storage device as density values for later education. The scanning time for a 30 cm x 30 cm plate with a step size of 10 micron will be less than 10 hours while the dynamic range of the data is expected to be 2.5 density units with an offset of at least 1 unit.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 317-328
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2006-02-14
    Description: The design and performance of the automated photographic measuring facility at Cambridge is described. It consists of a precision laser scanning microdensitometer connected to a series of computers that process the data on-line. Plates up to 350 mm square can be measured. The microdensitometer samples the plate to 12 bit accuracy at a speed of 230,000 samples/second. The positional accuracy is better than a micron. Other features include platen rotation and automatic focus.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 277-288
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The expected performance of the Minnesota automated dual-plate scanner (APS) is discussed with regard to photometry, position measurement accuracy, and ability to classify images. In addition, a fast algorithm for calculating image parameters is described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 267-276
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2006-02-14
    Description: Various aspects of the performance of the PDS 1010A microdensitometer are described. The primary points in an upgrade propsal for the unit are outlined. Photometric instabilities in the PDS are mentioned.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 129-134
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Minor modifications of electronic components in the PDS 1010A microdensitometer are discussed. The operational requirements and performance limitations of the PDS are noted. Replacement of the photomultiplier and front-end analog circuitry significantly improved the photometric performance of the PDS. The improvement in density repeatability is marked, and the permissible density slew speed is greatly increased.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 121-128
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2006-02-14
    Description: High Altitude Observatory HAO microdensitometer undergoes monthly testing to assure its consistent performance. These tests check positional and photometric stability at the 10 micron aperture level. The HAO test procedure is designed to run without operator intervention following initial configuration of the microdensitometer for each subprocedure. Specialized test software is resident in the PDP 8. The operator selects the proper subprocedure by entering commands. Once computer control is established, it is not relinquished until the test is complete.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Astron. Microdensitometry Conf.; p 19-34
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Publication Date: 2006-02-14
    Description: A number of diagnostic tests are developed for the Photometric Data System PDS 2020G microdensitometer to monitor its performance and to isolate various electromechanical problems. A number of tests which help to diagnose problems with the photometer, positional accuracy and data collection are described. The tests include: (1) scanning a razor blade edge to study the response of the photometer and zero point losses in the coordinate system, (2) scanning a long straight line to evaluate the drunkness of the stage motions, (3) scanning photometric step wedge calibrations to study the response of the photometer, and (4) measurement of a series of high signal to noise plates of the same region of the sky to evaluate the overall performance of the microdensitometer. A variety of electronic tests to isolate electromechanical problems are also performed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 3-18
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The behavior of ruled and holographic gratings with various coatings after extended exposure to the space environments was examined. The coatings and differentiating between the influences of vacuum and solar illumination were examined. In the past, several ruled and holographic gratings with various coatings were successfully flown on rocket experiments. Future utilizations of such gratings are considered for the Space Telescope and for various Spacelab projects under development. The techniques which is used to replicate gratings can also be used to obtain a wide range of lightweight optical components, including sophisticated aspherical, highly polished mirrors.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 163-164
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Publication Date: 2006-02-14
    Description: Electro-optic holographic recording systems were developed. The spaceworthiness of electro-optic crystals for use in ultrahigh capacity space data storage and retrieval systems are examined. The crystals for this experiment are included with the various electro-optical components of LDEF experiment. The effects of long-duration exposure on active optical system components is investigated. The concept of data storage in an optical-phase holographic memory is illustrated.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 152-153
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Publication Date: 2006-02-14
    Description: The specific scientific objectives of this experiment are to measure the spatial distribution, size, velocity, radiance, and composition of microparticles in near-Earth space. The technological objectives are to measure erosion rates resulting from microparticle impacts and to evaluate thin-foil meteor 'bumpers'. The combinations of sensitivity and reliability in this experiment will provide up to 1000 impacts per month for laboratory analysis and will extend current sensitivity limits by 5 orders of magnitude in mass.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 117-120
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-04
    Description: The active cavity radiometer (ACR) experiment on the Spacelab 1 mission to measure the total solar irradiance is discussed. Short and long term variations in the total solar output of optical energy are studied. Solar total irradiance observation provides information on the solar cycle and other long term trends in solar output that are of climatological significance as well as short term solar physics phenomena. The interaction of solar radiation with the Earth's atmosphere, oceans, and land masses provides the primary driving forces for the formation of weather systems and the determination of climate. Astrophysical measurements determine the total energy flux. The principal role of the ACR observations support extended solar irradiance experiments on free flying satellites. Solar irradiance measurements are important in the establishment of the radiation scale at the solar total flux level in the international system of units (SI).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 4 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-04
    Description: The study of galactic and faint extragalactic extended sources and peculiar ultraviolet objects by a very wide field of view camera, operated in the ultraviolet photometric and spectrometric modes is discussed. The photometric mode is direct photography through filters for observation of the following sources: (1) large scale distribution of ultraviolet radiation in the Milky Way; (2) diffusion of the galactic light above the galactic plane and in front of the large absorbing clouds; (3) the optical emission of the interstellar matter; (4) stars, and starlike objects with diameters less than 3 arc minutes. In the spectrometric mode (nebular spectrograph) the light from the center of the photometric field is concentrated on a slit covering 10 degrees by 10 arc minutes on the sky.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 3 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-05
    Description: The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 2 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-04
    Description: A test of the mapping capabilities of high resolution space photography taken at the resolution limit of image motion on large film format is planned. The metric camera system and its planned operation are described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 4 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-04
    Description: Photography and measurement of cloud-like structures of bright parallel bands observed in near infrared photography of the night sky is planned. The instrument is described and the purpose of the experiment summarized.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 2 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-04
    Description: High resolution infrared spectroscopic observations of the Earth's limb in the wavelength range characteristic of the vibrational-rotational lines of trace atmospheric constituents is planned. The instrument and its operation and the purpose of the experiments are summarized.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 3 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The counter is a static thermal diffusion chamber which has been modified to include an optical system for the determination of droplet concentration by the measurement of scattered light. The determination of concentration is made by measurement of the peak scattered light signal from the cloud of growing droplets which is a function of both the droplet concentration and chamber supersaturation. Because the formation of the peak is related to the rate of growth of the droplets and sedimentation, both of which are determined by supersaturation, the system calibration can be uniquely determined by comparison with an absolute counter such as a static diffusion chamber with a photographic recording system.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 40-41
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Publication Date: 2006-02-14
    Description: Unlike typical CCN counters, this device counts the numbers of water droplets condensed on aerosol particles sampled on a microcover glass at various different relative humidities. The relative humidities ranged from 75 percent to a calculated value of 110 percent. A schematic of the apparatus is shown. The individual CCN can be identified in an optical micrograph and scanning electron micrograph and may be inspected for their chemical composition later.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 35-36
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Publication Date: 2006-02-14
    Description: In performing the data analysis of the measurements achieved during the Workshop with the device, a global approach was preferred rather than an individual analysis, in order to illustrate some main characteristics in the behavior of the device with respect to a mean behavior resulting from a general survey of all the equipments involved in each experiment. The device tends generally to overestimate the CCN concentrations measured near the high supersaturations and sometimes underestimates the concentrations close to 0.1% or 0.2% of supersaturation. Despite the fact that it belongs to a type of static diffusion chamber, it shows, however, similar spectra to those obtained with other types of chambers (continuous flow diffusion chamber and haze chamber).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 17-19
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Publication Date: 2006-02-14
    Description: The group's CCN counter is described. It is a static, horizontal, parallel plate thermal gradient diffusion chamber. Examples of the application of the CCN are presented and include the CCN spectra measured during the winter of 1978-79 near Elk Mountain, Wyoming. Comparisons of droplet concentrations derived from upwind CCN spectra are covered.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 11-13
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Publication Date: 2006-02-14
    Description: The size distribution was measured in the size range between 0.0057 and 0.57 micrometer radius. A description of the instrumentation and data analysis is given, together with the measured size distributions calculated for 23 experiments.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 69-78
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Publication Date: 2006-02-14
    Description: The experiments performed at the Workshop were undertaken to confirm the calculated sample volume, determine the usable range of supersaturation, and minimum detectable size. Comparison of absolute CCN concentrations with other state-of-the-art continuous flow diffusion chambers at supersaturations near 1 percent indicated that the volume used produced CCN concentrations well within the range of CCN concentrations determined at the workshop. This agreement is interpreted to mean the sample volume was correct. Direct measurements of the beam geometry done in the laboratory indicated a factor of 4-5 error. This error is apparently due to the larger apparent visible beam diameter versus the actual usable beam diameter given the droplet illumination, chamber optical geometry, microscope optics and film characteristics.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 44-45
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Publication Date: 2006-01-16
    Description: A multi-channel chopper system designed and built to stringent specifications is providing an excellent performance for a total ozone mapping spectrometer (TOMS). State of the art machining technology, suitable material selection, and a way to hold and position the slit plate resulted in the instrument's better than expected performance. A shutter method used for internal calibration allows compensation for the occurrence of an unlikely wavelength shift during testing, launch, or during the orbiting life of the instrument. The TOMS is part of a payload on Nimbus 7 launched on October 24, 1978.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center The 15th aerospace Mech. Symp.; p 63-75
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: In the IHC the critical supersaturation is inferred from the measurement of the size of particles which have grown to their equilibrium size at exactly 100 percent RH. The largest size channel corresponds to a critical supersaturation of 0.014 percent. The growth time required for particles of this size to reach their equilibrium size exceeds the 110 second residence time in the IHC. Since the supersaturation spectrum is always very steep in this region, the contribution of these larger particles which have not yet attained their equilibrium size to smaller size channels is negligible. However, failure of these particles to reach their equilibrium size could result in a significant lowering of the count in the size channel corresponding to the smaller critical supersaturation.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 42-43
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The chamber geometry and optical arrangement are described. The supersaturation range is given and consists of readings taken at five fixed points: 0.25%, 0.5%, 0.75%, 1.0%, and 1.25%. The detection system is described including light source, cameras, and photocell detectors. The temperature control and the calibration of the chamber are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 26-27
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Publication Date: 2006-02-14
    Description: The NRL thermal gradient diffusion cloud chamber (TGDCC) consists of two plates 7.5 cm in diameter separated by 1.25 cm and covered with saturated filter paper. The cylindrical wall separating the plates is glass. The top plate is at room temperature and the bottom plate is cooled with a thermoelectric cooler. The temperature difference is measured with several sets of thermocouples. The CCN concentration was determined from the video recording. This procedure of averaging the maximum count obtained on several successive recordings at the same supersaturation results in concentrations which are somewhat higher than concentrations calculated from an average across the plateau.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 14-16
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Two instruments were used to size dry aerosols for the CCN experiments: the Naval Research Laboratory (NRL) instrument which uses an electrical mobility analyzer to separate the aerosol size fractions and a diffusion chamber to grow and count the particles and the University of Wyoming (WYO) aerosol monitoring system. Measurements from these two systems were usually found to be in agreement during the CCN Workshop. Two examples are presented to compare aerosol size distribution measurements of the two instruments: experiment 8 (monodisperse NaCl) and experiment 27 (polydisperse AgI). Differential (dN/dR) and cumulative plots are shown for both instruments for experiment 8 and experiment 27; also shown are Aitken particle measurements for comparison.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 106-107
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Publication Date: 2006-02-14
    Description: Nine CCN counters of the static diffusion (SDC) type were compared with one another and with continuous flow diffusion (CFD) chambers. The nine SDCs showed a considerable amount of variation, largely attributable to newness and/or lack of prior calibration of some units. The five more consistent instruments agreed quite well, to within at least 20 percent of the NRL mobility analyzer and to within 10 percent at 1 percent supersaturation. There was satisfactory agreement between the more reliable SDC and CFD chambers.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 57-63
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The diffusion tube was designed to operate below about 0.25 percent of water supersaturation. It is simply a long tube lined on the inside with a damp chamois cloth, and heated isothermally to a few degrees centigrade above the incoming air. The diffusion coefficient for water vapor is slightly larger than that for heat, making it possible to supersaturate the airflow. This is the same principle by which transient supersaturations may occur in parallel plate cloud chambers. Only the diffusion of vapor and heat from the walls into the moving air are considered.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 37-39
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Publication Date: 2006-02-14
    Description: The chamber is a thermal gradient diffusion type with the upper plate at room temperature and the lower plate thermoelectrically cooled. The light from a 25W projector bulb is focused in a beam of approximations 1x3 mm in the central part of the chamber. The light scattered by drops is viewed in the forward direction (40 deg) by a microscope and a sensitive photodetector. Experiments were performed to relate the peak output from the photocell with the maximum number of drops in the beam recorded photographically. The microscope is used to check the calibration at low concentrations of CCN. The results of the experiments and the performance of the counter are reported.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 33-34
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Publication Date: 2006-02-14
    Description: One of the principal advantages of electrography when compared to photography is the nearly linear relationship between source intensity versus resulting image density. This property allows for simplified and more accurate photometric calibration and permits a certain degree of extrapolation of the calibration to beyond the limits of the faintest photoelectric standard on an exposure. The desires to extract quantitative photometric information from electrographic (or photographic) negatives and to convert this information into a digital format for computer analysis or enhancement led to the widespread use of scanning microdensitometers to perform this A-to-D conversion. Therefore it is of vital importance to understand and, if practical, to avoid any nonlinearities which may be introduced during microdensitometry of electrographic emulsions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 429-431
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Publication Date: 2006-02-14
    Description: The scanning of a direct plate with the automatic plate measuring machine which results in the automated selection and description of images is described. The selection of QSO candidates based on color-color diagrams constructed from the APM image data and the analysis of APM raster data for QSOs selected visually from objective prism plates are also discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 417-418
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The fundamental limitations of microdensitometers are reviewed and the design of a high microdensitometer described. The system will digitize to 16 bits in transmission at a speed of 100 kHz using a laser beam moving over the emulsion. Other features are automatic platen rotation and autofocus. The cost will be of order $200,000.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 333-341
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: A new photographic measuring machine is under construction at the Paris Observatory. The amount of transmitted light is measured by a linear array of 1024 photodiodes. Carriage control, data acquisition and on line processing are performed by microprocessors, a S.E.L. 32/27 computer, and an AP 120-B Array Processor. It is expected that a Schmidt telescope plate of size 360 mm square will be scanned in one hour with pixel size of ten microns.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 329-332
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Publication Date: 2006-02-14
    Description: A diode-array based image digitizer manufactured by the Eikonix Corp. was tested to see if it can be adapted to the exacting requirements of astronomical densitometry. As the device is presently configured, a dynamic range of 400:1 can be achieved routinely, with a positional accuracy of 2 microns or better. An area of 2048 X 2048 pixels can be scanned in about 5 minutes. Preliminary tests indicate that several relatively simple enhancements can improve both the photometric and the positional accuracy of the device.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 307-315
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Motivations for construction of a next generation microdensitometer (NGM) are presented and their effect on the NGM design is discussed. A prototype of such an engine has been constructed at KPNO. Its design and performance is reviewed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 291-305
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The motivations for constructing a special purpose built microdensitometer are explored. The salient points of some of the microdensitometers are described and the advantages and disadvantages of the system in comparison to a PDS machine are outlined. The principal gain is in speed though at the expense of loss in dynamic range. The effects on the astronomical results are demonstrated. The astronomical results already obtained with these machines and from ongoing projects are described. It is shown that there is a large class of important astronomical problems which can be tackled by these machines but which are not feasibile on the PDS because of the speed of the machine.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 209-228
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Publication Date: 2006-02-14
    Description: The necessity to incorporate several hardware changes to optimize the Yale PDS 2020G microdensitometer for photometric and astrometric research are discussed. The properties of a new high speed photometer and a positional calibration system are described. The new photometer incorporates a high speed logarithmic analog to digital converter with more than 10 times the resolution of the former system and a cycle time of approximately 50 usec. The positional calibration system monitors the drunkenness of the stages with respect to fixed index lines and enables the correction of the +/- 5 micro stage errors to an accuracy of better than 1 micro.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 151-161
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The astrometric and photometric performance of the PDS 1010A microdensitometer are discussed, including the tests used for checking it. The instrument was shown to satisfy operational requirements for photometric measurements of astronomical plates with respect to dynamic range and stability.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 89-95
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Publication Date: 2006-02-14
    Description: The results of several parametric studies carried out on the Marshall Space Flight Center (MSFC) Photometric Data System PDS-10 microdensitometer are summarized for the purposes of documenting the operation and limitations of the system for inhouse research and to provide a bench mark for comparison with other microdensitometers. The results are grouped into four general areas. These are: (1) system overall stability to drift, (2) photometric linearity and noise, (3) reproducibility, and (4) scanning performance. Test data taken in order to evaluate the interdependency of scan speed, noise and position are included. Shown also are results of tests for system stability, reproducibility, stray light and PMT settling time.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Astron. Microdensitometry Conf.; p 71-88
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Publication Date: 2006-02-14
    Description: The performance of densitometers used for photometric data reduction of high dynamic range electrographic plate material is analyzed. Densitometer repeatability is tested by comparing two scans of one plate. Internal densitometer errors are examined by constructing histograms of digitized densities and finding inoperative bits and differential nonlinearity in the analog to digital converter. Such problems appear common to the four densitometers used in this investigation and introduce systematic algorithm dependent errors in the results. Strategies to improve densitometer performance are suggested.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 45-58
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Various perturbations which occurred during the operation of a PDS 2020 GM microdensitometer are reviewed. The effects of elevated temperature, vibration, transient electrical noise, and photometric perturbations are briefly discussed. Sample astronomical results from the PDS 2020 GM unit are presented.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 97-106
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Publication Date: 2006-02-14
    Description: Digitizing flatfield images produces conditions in the Photometric Data System PDS which cause the measured density to drift by as much as .1 DN during a 10 minute interval. The drift occurs when the PDS, set up in equilibrium at fog level, subsequently scans a reasonably dense region for periods of longer than a few minutes. The drift is manifested primarily as a positive shift in density that is approximately the same for all densities. If the fog level is assumed to be in fact constant and is monitored during scans of flat fields, the PDS drift may be removed by subtracting the difference between the observed fog level and its assumed constant value for each pixel. This function is then smoothed and subtracted, as a function of scan line, from the measured density. The fog level is then adjusted to a standard value by adding a constant. The result is a flattened scan with PDS drift removed to the accuracy within which the fog level drift matches the drift at other levels.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Astron. Microdensitometry Conf.; p 59-69
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Publication Date: 2006-02-14
    Description: The photometric and positional accuracy of a microdensitometer is examined. A calibrating plate with different density areas available is used to determine photometric accuracy. Position accuracy is evaluated by multiple scans of sharp edges and analyzed statistically.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 35-43
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Many of the passive experiments flying on LDEF will be significantly enhanced if data are available postflight to indicate the temperature time histories of test materials and other specimens exposed in the experiments. The baseline LDEF approach was to provide postflight calculated temperature histories of experiment boundaries and solar flux data for the mission, which can in turn be used by each investigator to calculate the temperature time histories for critical experiment components. Without in-flight temperature measurements, a substantial uncertainty will exist in the calculated temperatures. The data measured by the themal measurement system (THERM) will significantly improve postflight knowledge of temperatures experienced by LDEF experiments. The THERM data will also be valuable in validating the LDEF thermal design concept and in providing better design data for experimenters on future LDEF missions. The objectives of this experiment are to determine the history of the interior average temperatures of the LDEF for the total orbital mission and to measure the temperatures of selected components and thermal boundary conditions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Long Duration Exposure Facility (LDEF); p 78-81
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Publication Date: 2011-08-18
    Description: Previously cited in issue 5, p. 642, Accession no. A83-16486
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA Journal (ISSN 0001-1452); 22; 1115-112
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Publication Date: 2011-08-18
    Description: The design of a high spectral resolution, lambda/delta lambda being approximately 1200 IR, sounder capable of increasing the vertical resolution of atmospheric temperature profiles and achieving a rms accuracy of approximately 1.5 K is discussed. This sounder permits improved determination of meteorological parameters on cloudiness, surface temperature, and air-surface interactions. A set of channels from the high J lines in the R branch of the 4.3-micron CO2 band complemented by a larger set of window, humidity, and temperature channels in the 3.7-, 6.3-, 9-, and 15-micron regions is used. Design and simulation studies show that such a sounder is within the present state of the art.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 979-989
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Publication Date: 2011-08-18
    Description: This paper presents the conceptual design of an instrument, called the solar disk sextant, to be used in space to measure the shape and the size of the sun and their variations. The instrumental parameters required to produce sufficient sensitivity to address the problems of solar oblateness, solar pulsations, and global size changes of climatic importance are given.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 1235-123
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Publication Date: 2011-08-18
    Description: Previously cited in issue 05, p. 643, Accession no. A83-16685
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA Journal (ISSN 0001-1452); 22; 557-559
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: A simple and inexpensive thermal diffusivity apparatus is described for measurement up to 1600 K. The novel features of apparatus include a light pipe, a long furnace, and a differential thermocouple. A low heat-load sample holder for clamping the sample in a vertical position is also described. The results of measurements on AXM-5Q graphite are reported.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments (ISSN 0034-6748); 55; 235-237
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Publication Date: 2011-08-19
    Description: A wave sensor, consisting of parallel, evenly spaced capacitance wires, whose output is the sum of the water surface deflections at the wires, has been built and tested in a wave tank. The probe output simulates Bragg scattering of electromagnetic waves from a water surface with waves; it can be used to simulate electromagnetic probing of the sea surface by radar. The study establishes that the wave probe, called the 'Harp' for short, will simulate Bragg scattering and that it can also be used to study nonlinear wave processes.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Atmospheric and Oceanic Technology (ISSN 0739-0572); 1; 358-371
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Publication Date: 2011-08-19
    Description: The standard balloon-borne radiosonde employed for synoptic meteorology provides vertical profiles of temperature, pressure, and humidity as a function of elapsed time. These parameters are used in the hypsometric equation to calculate the geopotential altitude at each sampling point during the balloon's flight. It is important that the vertical location information be accurate. The present investigation was conducted with the objective to evaluate the altitude determination accuracy of the standard radiosonde throughout the entire balloon profile. The tests included two other commercially available pressure sensors to see if they could provide improved accuracy in the stratosphere. The pressure-measuring performance of standard baroswitches, premium baroswitches, and hypsometers in balloon-borne sondes was correlated with tracking radars. It was found that the standard and premium baroswitches perform well up to about 25 km altitude, while hypsometers provide more reliable data above 25 km.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Atmospheric and Oceanic Technology (ISSN 0739-0572); 1; 321-327
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Publication Date: 2011-08-19
    Description: This paper presents an algorithm for azimuth correlation of synthetic aperture radar (SAR) data with extraordinarily large-range migration which cannot be accommodated by the existing frequency domain interpolation approach used in current Seasat SAR processing. A mathematical model is provided for the SAR range-correlated point-target response both in the spatial and frequency domains. A simple and efficient processing algorithm derived from the exact two-dimensional correlation algorithm is given. This algorithm enables azimuth correlation by two cascaded one-dimensional correlation steps. The first step is to transform the range-correlated SAR data into the frequency domain in azimuth, followed by a newly developed range convolution filter to correct the range-dispersed spectrum of the range-correlated point-target response (RCPTR). The second step is the frequency-domain range migration correction approach for the azimuth compression. Simulation results provided here indicate that this processing algorithm yields a satisfactory compressed impulse response for SAR data with large-range migration whereas previous methods were subject to a broadening of the impulse response along range.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Geoscience and Remote Sensing (ISSN 0196-2892); GE-22; 592-597
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Publication Date: 2011-08-18
    Description: The laser-induced fluorescence (LIF) of green plants was evaluated as a means of remotely detecting plant stress and determining plant type. Corn and soybeans were used as representatives of monocots and dicots, respectively, in these studies. The fluorescence spectra of several plant pigments was excited with a nitrogen laser emitting at 337 nm. Intact leaves from corn and soybeans also fluoresced using the nitrogen laser. The two plant species exhibited fluorescence spectra which had three maxima in common at 440, 690, and 740 nm. However, the relative intensities of these maxima were distinctly different for the two species. Soybeans had an additional slight maxima at 525 nm. Potassium deficiency in corn caused an increase in fluorescence at 690 and 740 nm. Simulated water stress in soybeans resulted in increased fluorescence at 440, 525, 690, and 740 nm. The inhibition of photosynthesis in soybeans by 3-(3-4-dichlorophenyl)-1-1-dimethyl urea (DCMU) gave incresed fluorescence primarily at 690 and 740 nm. Chlorosis as occurring in senescent soybean leaves caused a decrease in fluorescence at 690 and 740 nm. These studies indicate that LIF measurements of plants offer the potential for remotely detecting certain types of stress condition and also for differentiating plant species.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 134-142
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Publication Date: 2011-08-19
    Description: The balloon-borne microwave limb sounder (BMLS) measures atmospheric thermal emission from millimeter wavelength spectral lines to determine vertical profiles of stratospheric species. The instrument flown to date operates at 205 GHz to measure ClO, O3, and H2O2. A 63 GHz radiometer will be added to test the technique for determining tangent point pressure from the MLS experiment on the upper atmosphere research satellite (UARS). Many additional species could also be measured by the BMLS. A radiometer at 270 GHz would provide measurements of HO2, NO2, HNO3, N2O, O-16O-18O-16, and HCN. With this addition, the BMLS can test the current theory of O3 photochemical balance in the upper stratosphere.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Quantitative Spectroscopy and Radiative Transfer (ISSN 0022-4073); 32; 407-433
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Publication Date: 2011-08-19
    Description: The present cryogenic blackbody reference, or 'cold load', for mm-wavelength radiation has an emissivity of more than 0.99 over a two-octave wavelength range and can be used as a calibrating standard for sensitive IR photometers. The transmittance spectrum obtained indicates that wave impedance and index do not vary significantly over the 80-360 GHz range.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Journal of Infrared and Millimeter Waves (ISSN 0195-9271); 5; 1507-151
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-19
    Description: This paper discusses the measurement and comparison of particle size and velocity measurements in sprays. The general nature of sprays and the development of standard, consistent research sprays are described. The instruments considered in this paper are: pulsed laser photography, holography, television, and cinematography; laser anemometry and interferometry using visibility, peak amplitude, and intensity ratioing; and laser diffraction. Calibration is by graticule, reticle, powders with known size distributions in liquid cells, monosize sprays, and, eventually, standard sprays. Statistical analyses including spatial and temporal long-time averaging as well as high-frequency response time histories with conditional sampling are examined. Previous attempts at comparing instruments, the making of simultaneous or consecutive measurements with similar types and different types of imaging, interferometric, and diffraction instruments are reviewed. A program of calibration and experiments for comparing and assessing different instruments is presented.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Publication Date: 2011-08-19
    Description: Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluoresence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the short-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 4076-408
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Publication Date: 2011-08-19
    Description: The response characteristics of laser diffraction particle sizing instruments were studied theoretically and experimentally. In particular, the extent of optical sample volume and the effects of receiving lens properties were investigated in detail. The experimental work was performed with a particle size analyzer using a calibration reticle containing a two-dimensional array of opaque circular disks on a glass substrate. The calibration slide simulated the forward-scattering characteristics of a Rosin-Rammler droplet size distribution. The reticle was analyzed with collection lenses of 63 mm, 100 mm, and 300 mm focal lengths using scattering inversion software that determined best-fit Rosin-Rammler size distribution parameters. The data differed from the predicted response for the reticle by about 10 percent. A set of calibration factor for the detector elements was determined that corrected for the nonideal response of the instrument. The response of the instrument was also measured as a function of reticle position, and the results confirmed a theoretical optical sample volume model presented here.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optical Engineering (ISSN 0091-3286); 23; 610-619
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Publication Date: 2011-08-18
    Description: A low-power portable data acquisition system presently in use for geomagnetic measurements is described. The system is composed of a data-processing system containing a low-power microprocessor, a 9-track digital tape recorder, and a rechargeable battery pack. The magnetometer is a low-power three axis fluxgate design. Under program control the data processing system keeps track of time of day and date, samples three analog magnetometer outputs at intervals of either 0.4 or 2 s, digitizes the data to 15-bit resolution, and, depending upon relative magnetic activity, decides upon data compression to increase the tape storage capacity. It also monitors and records internal voltages and provides self-checking functions which may be monitored through a visual readout on the control panel. The system is mounted in a rugged, weather-tight carrying case suitable for use outdoors with minimal protection. The system, including magnetometer, uses 1.6-W power and can store 5.7 Mbytes of data.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Geoscience and Remote Sensing; GE-19; July 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Publication Date: 2011-08-18
    Description: Advances in instrumentation for use in nuclear-science studies are described. Consideration is given to medical instrumentation, computerized fluoroscopy, environmental instrumentation, data acquisition techniques, semiconductor detectors, microchannel plates and photomultiplier tubes, reactor instrumentation, neutron detectors and proportional counters, and space instrumentation.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Publication Date: 2011-08-18
    Description: Experiments have been done to study the performance of mercuric iodide (HgI2) detectors in the ultralow-energy X-ray region. Energy resolution values of 245 eV (FWHM) for the Mg K-alpha X-ray line at 1.25 keV and 225 eV (FWHM) for the electronic noise linewidth have been obtained for an HgI2 detector with painted carbon contacts using a pulsed-light feedback preamplifier; the whole system was operated at room temperature. The resolution values in the ultralow-energy region are still limited by electronic noise of the system. In an attempt to minimize X-ray attenuation in the front contact, detectors were prepared with thin evaporated Pd contacts. These detectors show a pronounced low-energy tailing of the photopeak below a few keV, in contrast to the spectra obtained by detectors with carbon contact. An attempt has been made to explain the tailing effect starting with models wich have been proposed to describe similar effects in Ge detectors.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Publication Date: 2011-08-18
    Description: The assumption that spherical-shell ion chamber rssponse is equal to the dose in the center of the cavity is found to be a poor approximation for ion chambers used for area monitoring in the space program. The dose response is calculated using the appropriate areal density distribution function. Effects of nuclear reaction are evaluated using proton buildup factors. Errors of up to 100% are found for some components of the space radiation environments.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Nuclear Technology; 52; 1, Ja; Jan. 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: A method is described of applying a variable frequency-shift to a laser beam, by means of Bragg cells, in which the direction of the output diffracted beam is unaffected by the magnitude of the applied shift. Applications of the technique to reference-beam and Doppler-difference forms of laser anemometry are discussed together with methods of obtaining increased dynamic range.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 20; Feb. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Publication Date: 2011-08-18
    Description: Fluorescence lidar when applicable offers one of the most sensitive methods for measuring the concentration of trace constituents of the atmosphere. In the conduct of a fluorescence lidar experiment, a number of parameters which can be used to optimize the SNR can be controlled. In this paper the optimum division of laser pulses centered on and off the fluorescence excitation wavelength is calculated as a function of the ratio of the fluorescence signal strength to the strength of fluorescence from interfering species. For strong interference signals the time should be divided equally on and off the line. For strong fluorescence signals the time on line is proportional to the square root of the on-line off-line signal ratio. The optimization of the integration time for varying values of signal-to-background and signal-to-interference ratios, atmospheric attenuation, laser energy variations, background measurement time, and on-line off-line time division is also considered.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 20; Feb. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: The use of laser Raman measurement techniques in remote sensing applications is surveyed. A feasibility index is defined as a means to characterize the practicality of a given remote Raman measurement application. Specific applications of Raman scattering to the measurement of atmospheric water vapor profiles, methane plumes from liquid natural gas spills, and subsurface ocean temperature profiles are described. This paper will survey the use of laser Raman measurement techniques in remote sensing applications using as examples specific systems that the Computer Genetics Corporation (CGC) group has developed and engineered.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optical Engineering; 20; Jan
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Publication Date: 2011-08-18
    Description: It is proposed to use high-resolution stimulated Raman spectroscopy to directly measure high-speed molecular flow velocities in wind tunnels and in combustive chambers. A feasibility study indicates that flow speeds from Mach 0.04 up may be measured with the proposed method using available laser systems. It is pointed out that the success of the proposed technique will make it possible to measure all interesting flow parameters, i.e., species concentration, temperature, and velocity, in a time of less than 1 microsecond at a repetition rate of 10,000/s using a single experimental arrangement.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Journal of Quantum Electronics; QE-17; Jan. 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: The distribution of image energy by the central obstruction of annular apertures is discussed with special emphasis on the effect of an aperture shape parameter which can be interpreted optically as the inverse obstruction ratio. This parameter generates group arrangements with the number of rings given by N2 = 1/a, where a is the central obstruction ratio.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 20; Jan. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: The construction, tests, and performance of a temperature stabilized phase detector are discussed. It has a frequency stability of 5 parts in 10 to the 16th power at 100 MHz, with a temperature step of 20 C (15 to 35 C).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommun. and Data Acquisition Progr. Rept. 42-64; p 90-95
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Publication Date: 2011-08-18
    Description: Electrical path delay caused by atmospheric water vapor may be a limiting error source for geodetic measurements made with VLBI. Direct measurement of atmospheric water vapor is necessary to obtain path delay correction required by the ORION project. A dual channel water vapor radiometer is described which operates at frequencies near the 22 GHz water vapor line and is capable of collecting data that permits calculation of path delay within 2 cm accuracy.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Telecommun. and Data Acquisition; p 10-14
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Publication Date: 2011-08-18
    Description: A new type of apparatus for high-pressure experiments at low temperature (1.5 K) is presented. It uses a flat diamond anvil with a spherical indentor. It utilizes a load ring placed under the sample, so that the load (and hence pressure) can be measured in situ at low temperature. The apparatus was successfully used to investigate the high-conductivity state of sulphur. It can be used to investigate other thin film samples.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments; 52; Feb. 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Publication Date: 2011-08-18
    Description: A system to be used for the tracking of high altitude chemical releases in the presence of a bright daytime sky is described. The system uses telecentric optics, a tilting filter, a solid state image sensor, and a real time digital processor to produce the release image. Field test data are presented.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 20; Mar. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Publication Date: 2011-08-18
    Description: An automated methane/total hydrocarbon analyzer is presented, which can produce alternate methane/total hydrocarbon measurements every 7 seconds to provide the spatial resolution required for regional hydrocarbon measurements at aircraft speeds. The construction and sampling techniques developed for the aircraft mounted system are discussed. A technique to periodically measure atmosphere oxygen is incorporated into the analyzer to ensure accurate hydrocarbon measurements, and a data collection methodology is developed to minimize errors resulting from changes in flame ionization detector sensitivity at different altitudes. Aircraft data acquired at the 1979 Southeastern Virginia Urban Plume Study are also presented, which illustrate the application of the instrument to a troposphere pollution plume.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments; 52; Oct. 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Publication Date: 2011-08-18
    Description: A multichannel scanning radiometer developed for remote observation of cloud physical properties is described. Consisting of six channels in the near infrared and one channel in the thermal infrared, the instrument can observe cloud physical parameters such as optical thickness, thermodynamic phase, cloud top altitude, and cloud top temperature. Measurement accuracy is quantified through flight tests on the NASA CV-990 and the NASA WB-57F, and is found to be limited by the harsh environment of the aircraft at flight altitude. The electronics, data system, and calibration of the instrument are also discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments; 52; Oct. 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Publication Date: 2011-08-18
    Description: A comparison of measured and predicted signal-to-noise ratio is made in an optical heterodyne spectrometer utilizing a tunable diode laser which exhibited excess noise. It is shown that good agreement between predicted and measured signal-to-noise ratios results if excess noise effects due to tunable diode lasers are included in the predictions. The methods used to quantify excess noise and to incorporate their effects into predictions of signal-to-noise ratio are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Physics Letters; 39; Nov. 1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: It is pointed out that no instrument is sensitive to only one oceanographic variable; rather, each responds to a combination of atmospheric and oceanic phenomena. This complicates data interpretation and usually requires that a number of observations, each sensitive to somewhat different phenomena, be combined to provide unambiguous information. The distinction between active and passive instruments is described. A block diagram illustrating the steps necessary to convert data from satellite instruments into oceanographic information is included, as is a diagram illustrating the operation of a radio-frequency radiometer. Attention is also given to the satellites that carry the various oceanographic instruments.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Oceanus; 24; Fall 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: The use of a laser diode as a light source for a schlieren system designed to study phase objects such as a wind-tunnel flow is explored. A laser diode schlieren photograph and a white light schlieren photograph (zirconium arc source) are presented for comparison. The laser diode has increased sensitivity, compared with light schlieren, without appreciable image degradiation, and is an acceptable source for schlieren flow visualization.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optical Engineering; 20; Sept
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Publication Date: 2011-08-18
    Description: An analysis method for Fourier transform spectroscopy is summarized with applications to various types of distortion in atmospheric absorption spectra. This analysis method includes the fast Fourier transform method for simulating the interferometric spectrum and the nonlinear least-squares method for retrieving the information from a measured spectrum. It is shown that spectral distortions can be simulated quite well and that the correct information can be retrieved from a distorted spectrum by this analysis technique.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 2604-261
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Publication Date: 2011-08-18
    Description: Sampling generally causes the response of a digital imaging system to be locally shift-variant and not directly amenable to Modulation Transfer Function (MTF) analysis. However, this paper demonstrates that a meaningful system response can be calculated by averaging over an ensemble of point-source system inputs to yield an MTF which accounts for the combined effects of image formation, sampling, and image reconstruction. As an illustration, the MTF of the Landsat MSS system is analyzed to reveal an average effective instantaneous field of view which is significantly larger than the commonly accepted value, particularly in the along-track direction where undersampling contributes markedly to an MTF reduction and resultant increase in image blur.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 2572-258
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Publication Date: 2011-08-18
    Description: Tests have been made of a nondispersive spectroscopic X-ray detector which operates by measuring the temperature rise following absorption of a single photon. Thermal pulses from 6-keV X-rays have been observed, and the different amplitudes resulting from Mn K-alpha and K-beta events have been resolved. This device was assembled to make quantitative tests of theoretical calculations of the properties of such detectors, and its high heat capacity does not allow it to attain the very high resolution predicted for detectors made by more sophisticated, but still straightforward, techniques. Both the measured resolution of 270-eV full width at half maximum and the absolute amplitude of the response are consistent with predictions. Nonthermal effects in the thermistor limit the precision of this comparison to about 30 percent.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Applied Physics (ISSN 0021-8979); 56; 1263-126
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Publication Date: 2011-08-18
    Description: Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Applied Physics (ISSN 0021-8979); 56; 1257-126
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: A large-aperture interferometer was devised by adding a local-reference-beam-generating optical system to a schlieren system. Two versions of the interferometer are demonstrated, one employing 12.7 cm (5 in.) diameter schlieren optics, the other employing 30.48 cm (12 in.) diameter parabolic mirrors in an off-axis system. In the latter configuration a cylindrical lens is introduced near the light source to correct for astigmatism. A zone plate is a satisfactory decollimating element in the reference-beam arm of the interferometer. Attempts to increase the flux and uniformity of irradiance in the reference beam by using a diffuser are discussed. Previously announced in STAR as N83-13979
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 1467-147
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Publication Date: 2011-08-18
    Description: A pulsed CO2 lidar was used to study statistical properties of signal returns from various rough surfaces at distances near 2 km. These included natural in situ topographic materials as well as man-made hard targets. Three lidar configurations were used: heterodyne detection with single temporal mode transmitter pulses, and direct detection with single and multiple temporal mode pulses. The significant differences in signal return statistics, due largely to speckle effects, are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 1412-141
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Publication Date: 2011-08-18
    Description: This paper illustrates a method for calibrating seven-hole probes to measure local total and static pressures and relative flow angles of up to 70 degrees in subsonic compressible flows. The method of Latin Squares was used to statistically sample a large and otherwise unmanageable data set, thereby reducing to a minimum the number of data points required to construct a polynomial curve fit to the data. Calibration produces three-variable third order polynomials which permit all of the desired flow properties to be found explicitly from probe measured pressures. This method determines the flow angles to within 2 degrees and Mach number to within 0.04 with 95 percent certainty.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Experiments in Fluids (ISSN 0723-4864); 2; 2, 19; 95-103
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Publication Date: 2011-08-18
    Description: The stratospheric mixing ratio of nitric oxide at an altitude of 36 km has been measured using a balloon-borne tunable diode laser (TDL) instrument operating in the 5.2-micron wavelength region. Currently the instrument operates with two TDLs, and the capability exists to measure four stratospheric species simultaneously: NO, NO2, O3, and H2O. During the NO measurements reported here, the second TDL operating near 6.2 microns was used to monitor water vapor concentration in the vicinity of the gondola by observing the 1889.57 per cm line absorption in the reference channel path length (1 m).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 1140-114
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: Attention is given to a microplasma discharge to initiate a hollow cathode discharge for such applications as plasma flow experiments, the electric propulsion of space vehicles, and as a replacement for filament cathodes in neutral beam injector ion sources. The technique results in a cathode that is easy to start, simple in design, and which does not require external RF exciters, inserts or heating elements. Future applications may include ion beam milling and ion implantation.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments; 52; Aug. 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Publication Date: 2011-08-18
    Description: An improved formula for continuous-wave ultrasonic phase velocity measurements using contact transducers is derived from the transmission line theory. The effect of transducer-sample coupling bonds is considered for measurements of solid samples even though it is often neglected because of the difficulty of accurately determining the bond thickness. Computer models show that the present formula is more accurate than previous expressions. Laboratory measurements using contacting transducers with the present formula are compared to measurements using noncontacting (hence effectively correction-free) capacitive transducers. The results of the experiments verify the validity and accuracy of the new formula.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Applied Physics; 52; May 1981
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Publication Date: 2016-06-07
    Description: To facilitate the navigation of spacecraft to the outer planets, Jupiter and beyond, the JPL-NASA Deep Space Network (DSN) has implemented three ensembles of atomic clocks at widely separated locations. These clocks must be maintained, synchronized, to with a few parts in 10 to the 13th power of each other and, the entire group must be maintained, to a lesser degree, in synchronism with Coordinated Universal Time (UTC)NBS/USNO. Over the last 1 1/2 years the DSN has been using Global Positioning Satellites (GPS) and Very Long Baseline Interferometry (VLBI) technology to perform these critical Frequency and Time (F&T) synchronization tasks. A year of F&T synchronization data collected from the intercomparison of 3 sets of cesium and hydrogen maser driven clock ensembles through the use of GPS and VLBI techniques are covered. Also covered, are some of the problems met and limitations of these two techniques at their present level of technology.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 447-465
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2016-06-07
    Description: The Fluids Experiment Apparatus FEA is a modular zero gravity chemistry/physics laboratory to support fundamental space processing research. It can be used to conduct basic and applied process or product experiments in general liquid chemistry, crystal growth, fluid mechanics, thermodynamics, and cell culturing. The various FEA subsystems are readily configured to perform a wide range of investigations.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center 2nd Symp. on Space Industrialization; p 333-341
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Publication Date: 2016-06-07
    Description: A demonstration test of burner liner strain measurements using resistance strain gages as well as a feasibility test of an optical speckle technique for strain measurement are presented. The strain gage results are reported. Ten Kanthal A-1 wire strain gages were used for low cycle fatigue strain measurements to 950 K and .002 apparent strain on a JT12D burner can in a high pressure (10 atmospheres) burner test. The procedure for use of the strain gages involved extensive precalibration and postcalibration to correct for cooling rate dependence, drift, and temperature effects. Results were repeatable within + or - .0002 to .0006 strain, with best results during fast decels from 950 K. The results agreed with analytical prediction based on an axisymmetric burner model, and results indicated a non-uniform circumferential distribution of axial strain, suggesting temperature streaking.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Lewis Research Center Turbine Engine Hot Section Technology, 1984; 16 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Publication Date: 2016-06-07
    Description: Laser anemometers are being developed for use in the turbine facilities at Lewis that are involved in the Turbine Engine Hot Section Technology Program. The status of the program is given along with some results accomplished since 1983.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Turbine Engine Hot Section Technology, 1984; 11 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Publication Date: 2016-06-07
    Description: The TRAK Systems' GOES Satellite Synchronized Time Code Generator is described. TRAK Systems has developed this timing instrument to supply improved accuracy over most existing GOES receiver clocks. A classical time code generator is integrated with a GOES receiver.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 411-418
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Publication Date: 2016-06-07
    Description: Work on an innovative design for miniature rubidium frequency standards has reached the pre-production demonstration stage at Litton Guidance and Control Systems. Pre-production units were built and tested under contract to the Rome Air Development Center of the U.S. Air Force Systems Command. The units, which are designed for use in tactical military applications, feature fast warm-up, low power consumption, and vibration insensitivity. The output stability under vibration is maintained without the need for external shock-mounts. The design objectives and test results are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 143-155
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Publication Date: 2016-06-07
    Description: The on-oribt operational performance of the frequency standards on the Global Positioning System (GPS) 1 to 10 NAVSTAR satellites are discussed. The history of the Rb frequency standards showing the improvements incorporated at various stages of the program and the corresponding results are presented. Also presented is the operational history of the NAVSTAR cesium frequency standards. The frequency standards configuration data presented covers the chronology of events from the concept validation satellites, NAVSTAR 1 to 10, starting in 1978 to the present, including the configurations of clocks to be used on the GPS Production Program. Data are presented showing the results of long-term laboratory testing of a production Rb frequency standard with the necessary data taken to calculate Delta F, drift, time error, and Allan variance.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 127-141
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Publication Date: 2016-06-07
    Description: The mechanisms of the instrument pointing system (IPS) are described. Particular emphasis is placed on the actuators which are necessary for operating the IPS. The actuators are described as follows: (1) two linear actuators that clamp the gimbals down during ascent and descent; (2) two linear actuators that attach the payload to the IPS during the mission, and release it into the payload clamps; (3) one rotational actuator that opens and closes the payload clamps; and (4) three identical drive units that represent the three orthogonal gimbal axes and are the prime movers for pointing. Design features, manufacturing problems, test performance, and results are presented.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center The 18th Aerospace Mech. Symp.; p 15-28
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Publication Date: 2014-09-27
    Description: In order to utilize the quantitative accuracy built into the Thematic Mapper effectively, more attention must be paid to calibration before launch, changes of calibration before launch, changes of calibration with time in orbit, and atmospheric interference with the measurements, especially in the 450 to 520 nanometer band. Recent experience with the Coastal Zone Color Scanner (CZCS) program has led to procedures wherein Rayleigh correction factors can be generated utilizing simultaneous surface truth data that empirically give correct upwelled surface radiances. Instruments, such as the CZCS, have shown that calibration changes first, and to the largest degree, at the shorter wave lengths, with lesser changes as wave length increases. These techniques are utilized to calculate a Rayleigh correction factor that, together with geometric terms, will give an accurate correction for this portion of the atmospheric contribution to the signal.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center LANDSAT-4 Sci. Invest. Summ., Including Dec. 1983 Workshop Results, Vol. 2; p 20
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...