ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Röntgenfluorescenz-Spektrometrie  (4)
  • Springer  (4)
  • Molecular Diversity Preservation International (MDPI)
  • 1965-1969  (4)
  • 1969  (4)
Collection
Publisher
  • Springer  (4)
  • Molecular Diversity Preservation International (MDPI)
Years
  • 1965-1969  (4)
Year
  • 1969  (4)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 280 (1969), S. 201-203 
    ISSN: 1618-2650
    Keywords: Best. von Calcium in Uran ; Röntgenfluorescenz-Spektrometrie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An X-ray fluorescence method for the analysis of calcium in uranium in the range of 20 to 500 ppm is described. U3O8 samples are mixed with boric acid binder and double-layer pellets are prepared. The pellets are analysed using Philips PW 1220 semi-automatic X-ray spectrometer. Calculated lower limits of detection are better than 5 ppm for calcium in uranium.
    Notes: Zusammenfassung Ein Verfahren für den Bereich von 20–500 ppm wird beschrieben. Die U3O8-Proben werden mit BorsÄure als Bindemittel vermischt zu Doppelschicht-Tabletten gepre\t, die mit Hilfe eines halbautomatischen Philips PW 1220 Röntgenspektrometers analysiert werden. Die untere Nachweisgrenze liegt bei 5 ppm Ca.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 280 (1969), S. 197-200 
    ISSN: 1618-2650
    Keywords: Best. von Spurenelementen in Staub ; Röntgenfluorescenz-Spektrometrie ; Radionuklidanregung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Röntgenfluorescenzanalyse von Staubproben mit Cd-109 als Strahlenquelle wird beschrieben. Für die Eichung des Verfahrens werden Kieselgelstandards verwendet. Die Korrektur der Matrixeffekte erfolgt mit Hilfe der Compton-Streupeaks. In den Staubproben werden neben den Elementen K, Ca, Ti, Fe, Rb, Sr, Y, Zr, die als natürliche Bestandteile des Bodens anzusehen sind, die Elemente Cr, Mn, Ni, Cu, Zn, Br und Pb nachgewiesen.
    Notes: Abstract The analysis of dust samples by X-ray fluorescence using Cd-109 as X-ray source is described. For calibration silica gel standards are used. The correction for matrix effects is carried out by means of the Compton peaks. Besides the elements K, Ca, Ti, Fe, Rb, Sr, Y, Zr, which may be considered to be natural components of the ground, the elements Cr, Mn, Ni, Cu, Zn, Br and Pb are determined in the dust samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 280 (1969), S. 109-114 
    ISSN: 1618-2650
    Keywords: Analyse von Wasser ; Röntgenfluorescenz-Spektrometrie ; Empfindlichkeiten, Nachweisgrenzen, 10 mCi-Am(241)-Quelle
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Seven trace elements ranging from chromium to barium were preconcentrated on Amberlite IR-120 cation exchange paper and determined in an energy dispersive X-ray fluorescence system using a 10 mCi241Am source. Sensitivities were experimentally determined and checked with theoretically calculated values. The detection limits are compared with elemental levels present in typical surface waters and those allowed in drinking water. Appropriate conclusions as to feasibility of such a system for environmental monitoring are drawn.
    Notes: Abstract Sieben Spurenelemente im Bereich von Chrom bis Barium wurden auf Amberlite IR-120 Kationenaustauschpapier angereichert und durch energiedispersive Röntgenfluorescenzanalyse mit einer 10 mCi241Am-Quelle bestimmt. Die Übereinstimmung der experimentell gemessenen mit den theoretisch berechneten Empfindlichkeiten wird geprüft. Die Nachweisgrenzen werden verglichen mit den in typischen Oberflächengewässern vorkommenden und den in Trinkwasser maximal erlaubten Elementkonzentrationen. Die Möglichkeit der Anwendung in der Umweltanalytik wird diskutiert.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 280 (1969), S. 193-196 
    ISSN: 1618-2650
    Keywords: Röntgenfluorescenz-Spektrometrie ; Kieselgelstandards für Spurenelemente
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Kieselgelstandards eignen sich für die Eichung der Bestimmung von Spurenelementen in pulverförmigen Proben durch Röntgenfluorescenzanalyse. Die Herstellung der Standards sowie die Untersuchungen auf Reproduzierbarkeit und Fehler werden beschrieben.
    Notes: Abstract Silica gel samples are suitable for calibration of trace element determination in powders by X-ray fluorescence. The preparation of the silica gel samples and the investigations related to reproducibility and errors are described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...