ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (39)
  • Molecular Diversity Preservation International  (39)
  • American Physical Society (APS)
  • Institute of Physics
  • 2020-2024  (39)
  • Energies. 2021; 14(11): 3352. Published 2021 Jun 07. doi: 10.3390/en14113352.  (1)
  • Energies. 2021; 14(16): 4845. Published 2021 Aug 09. doi: 10.3390/en14164845.  (1)
  • Energies. 2021; 14(21): 6931. Published 2021 Oct 21. doi: 10.3390/en14216931.  (1)
  • Energies. 2021; 14(21): 6962. Published 2021 Oct 22. doi: 10.3390/en14216962.  (1)
  • Energies. 2021; 14(21): 7018. Published 2021 Oct 26. doi: 10.3390/en14217018.  (1)
  • Energies. 2021; 14(21): 7032. Published 2021 Oct 27. doi: 10.3390/en14217032.  (1)
  • Energies. 2021; 14(21): 7038. Published 2021 Oct 27. doi: 10.3390/en14217038.  (1)
  • Energies. 2021; 14(21): 7045. Published 2021 Oct 28. doi: 10.3390/en14217045.  (1)
  • Energies. 2021; 14(21): 7046. Published 2021 Oct 28. doi: 10.3390/en14217046.  (1)
  • Energies. 2021; 14(21): 7047. Published 2021 Oct 28. doi: 10.3390/en14217047.  (1)
  • Energies. 2021; 14(21): 7048. Published 2021 Oct 28. doi: 10.3390/en14217048.  (1)
  • Energies. 2021; 14(21): 7049. Published 2021 Oct 28. doi: 10.3390/en14217049.  (1)
  • Energies. 2021; 14(21): 7050. Published 2021 Oct 28. doi: 10.3390/en14217050.  (1)
  • Energies. 2021; 14(21): 7051. Published 2021 Oct 28. doi: 10.3390/en14217051.  (1)
  • Energies. 2021; 14(21): 7052. Published 2021 Oct 28. doi: 10.3390/en14217052.  (1)
  • 109050
Collection
  • Articles  (39)
Publisher
  • Molecular Diversity Preservation International  (39)
  • American Physical Society (APS)
  • Institute of Physics
Years
Year
Journal
  • 1
    Publication Date: 2021-10-26
    Description: Energy Transition (ET) needs actors to perform independent actions on multiple levels of governance. These actors may need to write and read their data, and at the same time they want to protect their data from unauthorized access. This is particularly the case for positive energy districts (PED), a growing trend in the EU that requires actors to perform, write and read operations on a neighborhood scale where governance competences are typically absent. This paper presents a decentralized privacy-aware data management framework that enables actors to store, read, and modify data in PEDs. Our framework design integrates blockchain with a Distributed Hash Table (DHT), role-based access control, ring signature, and different encryption techniques. The proposed framework stores encrypted data on the DHT, and metadata and hash key are sent to the blockchain, which allows the data owner to keep track of their data. The proposed framework components handle multi-level data access in PEDs and enable data security at run-time. Moreover, we show security and privacy analysis and performance evaluation in time overhead. The results show that the proposed solution is effective, secure, and scalable.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2021-10-21
    Description: Shared mobility based on cars refers to a transportation mode in which travelers/drivers share vehicles to reduce the cost of the journey, emissions, air pollution and parking demands. Cost savings provide a strong incentive for the shared mobility mode. As cost savings are due to cooperation of the stakeholders in shared mobility systems, they should be properly divided and allocated to relevant participants. Improper allocation of cost savings will lead to dissatisfaction of drivers/passengers and hinder acceptance of the shared mobility mode. In practice, several schemes based on proportional methods to allocate cost savings have been proposed in shared mobility systems. However, there is neither a guideline for selecting these proportional methods nor a comparative study on effectiveness of these proportional methods. Although shared mobility has attracted much attention in the research community, there is still a lack of study of the influence of cost saving allocation schemes on performance of shared mobility systems. Motivated by deficiencies of existing studies, this paper aims to compare three proportional cost savings allocation schemes by analyzing their performance in terms of the numbers of acceptable rides under different schemes. We focus on ridesharing based on cars in this study. The main contribution is to develop theory based on our analysis to characterize the performance under different schemes to provide a guideline for selecting these proportional methods. The theory developed is verified by conducting experiments based on real geographical data.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2021-10-27
    Description: The rapid growth of the Information and Communications Technology (ICT) sector requires additional infrastructure, such as more micro-datacenters and telecom stations, to support the higher internet speeds and low latency requirements of 5G networks. The increased power requirements of the new ICT technologies necessitate the proposal of new power supplies, in an attempt to support the increase in energy demand and running costs. This work provides an in-depth theoretical analysis on the losses of the individual stages of commercially available PSU and proposes a new multicell PSU, the buck PFC converter, which offers a higher overall efficiency at varying load levels. The theoretical results are verified using simulation results, via a PSIM Thermal Module, and using experimental data. The results indicate that multicell structures can improve the overall PSU efficiency by 1.2% at 50% rated power and more than 2.1% at full power. Finally, taking into consideration the economic implications of this study, it is shown that the proposed multicell structure may increase the PSU costs by 10.78%, but the payback period is in the order of just 3.3 years.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2021-10-27
    Description: Disposal of municipal solid wastes (MSW) remains a challenge to minimize its impacts on the environment and human health. Landfilling, currently the most common method used for MSW disposal, occupies land space and leads to soil and air emissions. Gasification, an alternative MSW disposal method, can convert waste to energy, but can also lead to soil and air emissions and is a more extensive operation. In this study, life cycle assessments (LCA) of the two disposal methods (landfilling without energy recovery and gasification) were compared to understand impacts on environment and health. The LCA was conducted following the ISO 14040 standards with one ton of MSW as the functional unit. The life cycle inventory was obtained from published journals, technical reports, LandGEM, HELP and GREET database. The impact assessment was done using TRACI 2.1 and categorized into eight groups. The LCA revealed that landfilling is a higher contributor in global warming, acidification, smog formation, eutrophication, ecotoxicity and human health cancer and non-cancer categories. The negative environmental impacts of MSW landfilling can be primarily attributed to the fate of leachate loss and landfill gas, while those of the MSW gasification can be attributed to the disposal of its solid residues.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2021-10-22
    Description: This article introduces an application of the recently developed hunger games search (HGS) optimization algorithm. The HGS is combined with chaotic maps to propose a new Chaotic Hunger Games search (CHGS). It is applied to solve the optimal power flow (OPF) problem. The OPF is solved to minimize the generation costs while satisfying the systems’ constraints. Moreover, the article presents optimal siting for mixed renewable energy sources, photovoltaics, and wind farms. Furthermore, the effect of adding renewable energy sources on the overall generation costs value is investigated. The exploration field of the optimization problem is the active output power of each generator in each studied system. The CHGS also obtains the best candidate design variables, which corresponds to the minimum possible cost function value. The robustness of the introduced CHGS algorithm is verified by performing the simulation 20 independent times for two standard IEEE systems—IEEE 57-bus and 118-bus systems. The results obtained are presented and analyzed. The CHGS-based OPF was found to be competitive and superior to other optimization algorithms applied to solve the same optimization problem in the literature. The contribution of this article is to test the improvement done to the proposed method when applied to the OPF problem, as well as the study of the addition of renewable energy sources on the introduced objective function.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2021-10-28
    Description: Monitoring the State of Charge (SoC) in battery cells is necessary to avoid damage and to extend battery life. Support Vector Machine (SVM) algorithms and Machine Learning techniques in general can provide real-time SoC estimation without the need to design a cell model. In this work, an SVM was trained by applying an Ant Colony Optimization method. The obtained trained model was 10-fold cross-validated and then designed in Hardware Description Language to be run on FPGA devices, enabling the design of low-cost and compact hardware. Thanks to the choice of a linear SVM kernel, the implemented architecture resulted in low resource usage (about 1.4% of Xilinx Artix7 XC7A100TFPGAG324C FPGA), allowing multiple instances of the SVM SoC estimator model to monitor multiple battery cells or modules, if needed. The ability of the model to maintain its good performance was further verified when applied to a dataset acquired from different driving cycles to the cycle used in the training phase, achieving a Root Mean Square Error of about 1.4%.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2021-10-28
    Description: The main goal of the research presented in this paper was the experimental and numerical analysis of heat enhancement and aerodynamic phenomena during air flow in a channel equipped with flow turbulators in the form of properly configured ribs. The use of ribs intensifies the heat transfer and at the same time increases not only the flow resistance but also the energy costs. Therefore, designing modern heat exchangers with optimal thermal and flow parameters requires the knowledge of the theory of heat exchangers as well as measurement methods and numerical calculations. Bearing in mind the above, the liquid crystal techniques (LCT), particle image velocimetry (PIV) and digital image processing (DIP) for temperature, velocity, friction factor and heat transfer coefficient measurements are presented herein. These three optical tools (using desktop computers) create an extremely powerful and advanced measuring technique that has not been available anywhere before. Brief histories of these measurement methods and techniques are discussed and some examples are presented. In order to assess and select the value of the measurement technique, local and average distributions of Nusselt numbers (in the measurement section) obtained by the transit analysis method on the inter-rib regions of a plate coated by thermochromics liquid crystal and heated by air as an alternative to the steady-state analysis. In the parallel, numerical calculation was performed with the use of the ANSYS Fluent software code and supported by laser anemometry-computed turbulence intensity of air flow. Comparison of the Nusselt number distributions was determined by three methods, i.e., steady state, the transient method and CFD simulation. Up to three-fold enhancement of the local heat transfer capability was observed. Failure to take into account the surface of the ribs in heat transfer causes differences in the obtained results of the Nusselt number depending on the method used. Apart from the heat transfer data, the pressure drop in the form of friction factors is also presented. On the basis of the conducted research, it can be stated that both qualitative and quantitative coherence was obtained between the experimental and computational studies.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2021-10-29
    Description: The electric power industry sector has become increasingly aware of how counterproductive voltage sag affects distribution network systems (DNS). The voltage sag backfires disastrously at the demand load side and affects equipment in DNS. To settle the voltage sag issue, this paper achieved its primary purpose to mitigate the voltage sag based on integrating a hydrogen fuel cell (HFC) with the DNS using a distribution static synchronous compensator (D-STATCOM) system. Besides, this paper discusses the challenges and opportunities of D-STATCOM in DNS. In this paper, using HFC is well-designed, modeled, and simulated to mitigate the voltage sag in DNS with a positive impact on the environment and an immediate response to the issue of the injection of voltage. Furthermore, this modeling and controller are particularly suitable in terms of cost-effectiveness as well as reliability based on the adaptive network fuzzy inference system (ANFIS), fuzzy logic system (FLC), and proportional–integral (P-I). The effectiveness of the MATLAB simulation is confirmed by implementing the system and carrying out a DNS connection, obtaining efficiencies over 94.5% at three-phase fault for values of injection voltage in HFC D-STATCOM using a P-I controller. Moreover, the HFC D-STATCOM using FLC proved capable of supporting the network by 97.00%. The HFC D-STATCOM based ANFIS proved capable of supporting the network by 98.00% in the DNS.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2021-10-28
    Description: A two-fold adaptive dynamic quadrilateral relay is developed in this research for protecting Thyristor-Controlled Series Compensator (TCSC)-compensated transmission lines (TLs). By investigating a new tilt angle and modifying the Takagi method to recognize the fault zone identifier, the proposed relay adapts its reactive reach and resistive reach separately and independently. The investigated tilt angle and identified fault zone use the TCSC reactance to compensate its effect on the TL parameters and system homogeneity. Excessive tests are simulated by MATLAB on the non-homogenous network, IEEE-9 bus system and further tests are carried out on IEEE-39 bus system in order to generalize and validate the efficiency of the proposed approach. The designed trip boundaries are able to detect wide range of resistive faults under all TCSC modes of operations. The proposed approach is easy to implement as there no need for data synchronization or a high level of computation and filtration. Moreover, the proposed adaptive dynamic relay can be applied for non-homogeneity systems and short as well as long TLs which are either TCSC-compensated or -uncompensated TLs.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2021-10-28
    Description: Renewable energy sources are ecological and sustainable solutions accepted with a common consensus under the sustainable development goals. Energy source exploration has enforced the human race to think about sustainable energy production as fossil fuels are non-renewable and are having a negative impact on ecosystem. Consumer needs and wants are the key for acceptance of renewable energy and making production a possibility. The real challenge is with the consumer market for the acceptance of green energy. The current research is based on the concept of GREEN consumer values synergizing with renewable energy sources, and eco innovation for sustainability in India. The crucial point of study is assessing GREEN consumer values which are the determining factor for consumption. All five renewable energy sources (solar, wind, hydro, geothermal and biomass) have received a higher level of acceptance by respondents which shows that India is on its way to enhancing its capacity for renewable energy. Indian consumer values are very much aligned with eco sustainability, and the market is ready to consume renewable energy.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Publication Date: 2021-10-28
    Description: This study evaluated a potential transition of India’s power sector to 100% wind and solar energy sources. Applying a macro-energy IDEEA (Indian Zero Carbon Energy Pathways) model to 32 regions and 114 locations of potential installation of wind energy and 60 locations of solar energy, we evaluated a 100% renewable power system in India as a concept. We considered 153 scenarios with varying sets of generating and balancing technologies to evaluate each intermittent energy source separately and their complementarity. Our analysis confirms the potential technical feasibility and long-term reliability of a 100% renewable system for India, even with solar and wind energy only. Such a dual energy source system can potentially deliver fivefold the annual demand of 2019. The robust, reliable supply can be achieved in the long term, as verified by 41 years of weather data. The required expansion of energy storage and the grid will depend on the wind and solar energy structure and the types of generating technologies. Solar energy mostly requires intraday balancing that can be achieved through storage or demand-side flexibility. Wind energy is more seasonal and spatially scattered, and benefits from the long-distance grid expansion for balancing. The complementarity of the two resources on a spatial scale reduces requirements for energy storage. The demand-side flexibility is the key in developing low-cost supply with minimum curtailments. This can be potentially achieved with the proposed two-level electricity market where electricity prices reflect variability of the supply. A modelled experiment with price signals demonstrates how balancing capacity depends on the price levels of guaranteed and flexible types of loads, and therefore, can be defined by the market.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Publication Date: 2021-10-28
    Description: A daylighting control system that uses the closed loop proportional algorithm needs to be calibrated both during nighttime and daytime. The selection of the daytime calibration time can affect the behavior of the system and is usually performed when the ratio of the illuminance of the ceiling sensor (SD,tc) to the illuminance at a point on the working plane (ED,tc) is relatively large without sunlight patches in the ceiling photo-sensor’s field of view (FOV). However, this requirement is not associated with a specific value and can be achieved under a wide range of conditions related to the sky luminance distribution. In the present work, four ceiling sensors with different field of views (FOVs) were examined in a typical north-facing office space. The effect of daytime calibration on the system’s performance was estimated through the calculation of lighting energy savings and the overdimming percentage. The results show that the effect of both the FOV of the ceiling sensor and the daytime calibration period is small except for the case of the sensor without cover, especially when it is close to the opening. In an attempt to quantify the SDtc/IDtc ratio, a new magnitude (RR) is proposed by dividing the illuminance ratios of the ceiling photo-sensor by that on the working surface during daytime and nighttime calibration. Thus, the daily calibration of the sensors with cover can be performed when RR 〉 1.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Publication Date: 2021-10-28
    Description: Increased use of energy in buildings and HVAC systems requires advanced control schemes like model-based control to improve energy efficiency, which in turn requires accurate thermodynamic models of buildings. The Resistive-Capacitive (RC) method is a popular and versatile approach for thermal modeling of buildings. Despite this, it is not easy to find practical solutions of implementation of the RC method. It is the goal of this paper to clarify the RC method and demonstrate simple implementation of this method, especially for multi-zone buildings, which have more potential for energy savings from use of model-based control. This paper provides two contributions. First is a detailed explanation of the RC method, focusing on its use for developing a structure of a model and first-principles approach for estimation of parameters of a model. Second is a demonstration of an algorithm that enables automatic development of the structure of a model from basic information about a building (layout, construction elements) and its combination with data-based parameter estimation. Use of the algorithm is presented with a case-study on industrial multi-zone building, for which such a grey-box model is developed and analyzed. The resulting model is rapidly developed and used in a simulation with the measured data. The outputs of the model are compared with the measured temperatures and they show good fit.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Publication Date: 2021-10-28
    Description: Two design flows of the Petri net-based cyber-physical systems oriented towards implementation in an FPGA are presented in the paper. The first method is based on the behavioural description of the system. The control part of the cyber-physical system is specified by an interpreted Petri net, and is described directly in the synthesisable Verilog hardware language for further implementation in the programmable device. The second technique involves splitting the design into sequential modules. In particular, adequate decomposition and synchronisation algorithms are proposed. The resulting modules are further modelled within the Verilog language as the composition of sequential automata. The presented design flows are supported by theoretical background, and templates of Verilog codes. The proposed techniques are illustrated by a real-life example of a multi-robot cyber-physical system, where each step of the proposed flows is explained in detail, including modelling, description of the system in the Verilog language, and final implementation within the FPGA device. The results obtained during the verification and validation confirm the proper functionality of the system designed by both design flows.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Publication Date: 2021-10-28
    Description: Vertical Axis Wind Turbines (VAWTs) are omnidirectional turbomachines commonly used in rural areas for small-to-medium-scale power generation. The complex flow observed in the wake region of VAWTs is affected by a number of factors, such as rotor blades design. A damaged rotor significantly alters the flow field in the wake region of the VAWT, degrading its power generation capability. Published literature on damaged wind turbine blades is severely limited to torque signal analysis and basic flow field description in the wake region. In this study, detailed numerical investigations have been carried out to establish and quantify the relationship between damaged rotor and the wake dynamics of a VAWT. Time-based Computational Fluid Dynamics analyses have been performed on two VAWT models, one undamaged and the other with a missing rotor blade. Proper Orthogonal Decomposition has been used to extract the energy content and temporal coefficients of the various flow patterns associated with the wake region. The results indicate that the first pressure-based flow mode contains 99% of the energy and provides a functional basis for accurate reconstruction of the wake. It is envisaged that this study will aid the development of novel machine learning algorithms for rotor damage detection in wind farms.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Publication Date: 2021-10-28
    Description: In our research, we analyzed the energy and water consumption in diamond mining and laboratory synthesis operations. We used publicly available reports issued by two market leaders, DeBeers and ALROSA, to estimate water and energy use per carat of a rough diamond. The efficiency of the two most popular synthesis technologies for artificial diamonds—High-Pressure-High-Temperature (HPHT) and Microwave-assisted Chemical Vapor Deposition (M-CVD)—was examined. We found that the modern HPHT presses, with open cooling circuits, consume about 36 kWh/ct when producing gem-quality and average-sized (near-) colorless diamonds. ALROSA and DeBeers use about 96 kWh/ct and 150 kWh/ct, respectively, including all energy required to mine. Energy consumption of M-CVD processes can be different and depends on technological conditions. Our M-CVD machine is the least energy-efficient, requiring about 215 kWh/ct in the single-crystal regime, using 2.45-GHz magnetron for the support synthesis. The M-CVD methods of individual synthetic companies IIa Technology and Ekati Mine are different from our results and equal 77 and 143 kWh/ct, respectively. Water consumption for the HPHT and M-CVD methods was insignificant: approximately zero and 0.002 m3/ct, respectively, and below 0.077 m3/ct for ALROSA-mined diamonds. This study touches upon the impact of the diamond production methods used on the carbon footprint.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Publication Date: 2021-10-28
    Description: This paper deals with the applicability of alternative power system configurations to reduce the environmental footprint of inland waterway ships. Its original contribution includes: models for assessment of the lifetime emissions and associated lifetime costs of alternative power system configurations for different types of inland waterway vessels, identification of the most cost-effective options for these vessels, and an estimation of the impact of emission policies on the profitability of each option. The case study considers the Croatian inland waterway sector, where three types of vessel with significantly different purposes, designs, and operative profiles are considered (cargo ship, passenger ship, and dredger). The technical and operational features of these ships are analyzed with an emphasis on their energy needs. Then, life-cycle assessments (LCAs) of a diesel engine-powered ship configuration and two battery-powered ship configurations (with and without a photovoltaic system) are performed by means of GREET 2020 software. These configurations are compared from the economical viewpoint, by the life-cycle cost assessment (LCCA), where potential carbon credit scenarios are investigated, while relevant quantities are converted into monetary units. Although the LCA identified the photovoltaic cells’ battery-powered ship configuration as the most environmentally friendly, according to the LCCA, its life-cycle costs are rather high, except for passenger ships, for which the battery-powered ship configuration is a feasible option. If a set of required specific input data is known, the presented procedure is applicable to reduce the environmental footprint of any other inland waterway fleet.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Publication Date: 2021-10-28
    Description: The most important design parameters of a moisture separator to optimize the efficiency of a nuclear power plant are the moisture carry over and pressure drop. An air-water test facility was constructed to evaluate the design parameters for various types of conventional moisture separators in Korea. In this study, a half scale of swirl-vane separator was designed, and test conditions were defined based on the scaling law to cover a wide range of operating conditions. The moisture carry over was measured using an isokinetic sampling system for 34 different flow conditions. The MCO was in range of 0.30–7.05% according to the test conditions. Single and two-phase flow experiments were also carried out to identify the two-phase pressure drop characteristics. Based on the obtained results, the proposed empirical correlation model was extended to a submerged separator and applying these results to a full scale system is discussed in this paper.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Publication Date: 2021-10-28
    Description: The increasing proportion of unconventional worldwide energy demands have consistently promoted the necessity for exploring a precise, high-resolution, objective, and quantitative stratigraphic division method for macroscopically homogeneous mudstone successions. The chemostratigraphy can resolve this problem well, although it has been applied successfully in North America, but not systematically studied in China for shale gas exploration and development. This work has conducted a chemostratigraphic analysis of Wufeng and Longmaxi Formation on the Changning section of Sichuan Province, southwestern China, to testify its applicability for shale gas exploration in China. Principal component analysis (PCA) was first employed to reduce the dimensionality of datasets. Three chemofacies, including detrital (K, Ti, Fe, Al, Na, Mg, Cr, Zr, Rb), authigenic (Ca, Sr, Mn, Si, S, Ba), and redox-organic (P, V, Ni, Zn, Cu, TOC), were found. Subsequently, constrained clustering analysis was utilized for the zonation of each chemofacies into chemozones. Consequently, the whole Changning section was divided into twelve chemozones (CZ I–CZ Ⅻ). The geochemical interpretation for these chemozones can be resolved from the regional changes in paleogeography and paleoceanography during the Late Ordovician to Early Silurian period. Thus, a three-stage geochemical evolution along the Changning section can be classified: (1) the siliceous and anoxic deposits of Wufeng Formation (CZ I–CZ III) with high TOC contents; (2) the siliceous and anoxic sedimentary rocks of bottom Longmaxi Formation with still higher TOC (CZ Ⅳ); (3) the calcarous-detrital and oxic sediments for the rest of Longmaxi Formation (CZ Ⅴ–CZ Ⅻ). In considering their high content of TOC and abundant brittle siliceous minerals, the CZ (I–Ⅳ, 0 m–33.6 m) are thought to be the most preferable sweet spot for shale gas exploration.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Publication Date: 2021-10-28
    Description: Energy saving is an important issue for multiple-chiller systems. Optimal chiller loading (OCL) in multiple-chiller systems has been investigated with many optimization algorithms to save energy. Particle swarm optimization (PSO) algorithm has been successful in solving this problem in some cases, but not in all. This study innovatively added a team evolution to the original particle swarm optimization algorithm, called team particle swarm optimization (TPSO). The TPSO enhances the effectiveness of original particle swarm optimization to better solve the OCL problem. The TPSO algorithm is composed of two evolutions: particle evolution and team evolution. The partial load ratio (PLR) of each operating chiller and the on-off state of each chiller are the particle evolution parameters and team evolution parameters, respectively. To evaluate the performance of the proposed method, this paper adopts three case studies so the results generated from the proposed algorithm TPSO, the original particle swarm optimization (PSO) and other recently published algorithms can be compared. In these three case studies, the optimal results generated by using TPSO algorithm are the same as those by other compared algorithms. In case 1 under 5717 RT and 5334 RT cooling load, the results generated using the TPSO are lower than those by the original PSO in the amounts of 63.35 and 79.33 kW, respectively. The results indicated that the TPSO algorithm not only enabled the optimal solution in minimizing energy consumption, but also demonstrated the best stability when compared to other algorithms. In conclusion, the presented TPSO algorithm is an efficient and promising new algorithm for solving the OCL problem.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Publication Date: 2021-10-28
    Description: Geothermal heat pumps have a widespread diffusion as they are able to deliver relatively higher energy output than other systems for building air-conditioning. The exploitation of low-enthalpy geothermal energy, however, presents crucial sustainability issues. This review investigates the primary forms of the environmental impact of geothermal heat pumps and the strategies for their mitigation. As life-cycle analyses shows that the highest impacts arise from installation and operation stages, most optimization studies focus on system thermodynamics, aiming at maximizing the energy performance via the optimization in the design of the different components interacting with the ground and serviced building. There are environmental studies of great relevance that investigate how the climate and ground properties affect the system sustainability and map the most suitable location for geothermal exploitation. Based on this review, ground-source heat pumps are a promising technology for the decarbonization of the building sector. However, a sustainable design of such systems is more complex than conventional air-conditioning systems, and it needs a holistic and multi-disciplinary approach to include the broad environmental boundaries to fully understand the environmental consequences of their operation.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Publication Date: 2021-10-28
    Description: A Net Zero Community (NZC) concept and its energy characteristics are presented in this paper. NZC is an emerging topic with multiple variations in terms of scope and calculated methods, which complicates quantifying its performance. This paper covers three key barriers in achieving NZC targets: (1) the main focus of current definitions on buildings, disregarding community power systems and energy use in transportation; (2) different requirements (source, supply, metrics, etc.) in the existing definitions; and (3) lack of updated published reports to track the progress of committed NZC targets. The importance of this research is summarized as due to increased savings in primary energy and greenhouse gas emissions related to the three main energy sectors, namely power systems, buildings, and transportation (PBT). To clarify the current NZC, this paper reviews: (1) variations in the existing definitions and criteria from peer-reviewed publications; (2) the latest climate projection models by policymakers to achieve net zero by 2050; (3) the literature on renewable-based power systems; and (4) three planned NZC cases in international locations, in order to study their NZC targets, energy performance, and challenges. The outcome highlights NZC design guidelines, including energy efficiency measures, electrification, and renewables in PBT sectors that help stakeholders including policymakers, developers, designers, and engineers speed up achievement of NZC targets.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Publication Date: 2021-10-28
    Description: The use of polymer composite materials in the aeronautics and automotive sectors has increased dramatically, and their fire behaviour has become a critical parameter in terms of fire safety. On this premise, it is critical to demonstrate that these composite materials constitute elements whose safety justifies a high level of confidence. This is based on their combustibility and the rate at which flammable and toxic gaseous species are emitted. Thus, strict fire safety regulations are enforced by the relevant authorities concerned because of their potential fire risk. This study analysed papers published between 1970 and 2021 that described the devices used to characterise the thermal behaviour of composite materials at various scales. The objective was to highlight the thermophysical phenomena, making it possible to accurately assess the flammability and thermal stability of polymer composite materials. The results of this research reveal that the small-scale facilities provide detailed understanding and mastery of the thermal reaction properties of the composites. While with the medium scale, the extended fire reaction parameters, which are the key indicators of the fire safety performance, can be determined. On a large scale, the tests were carried out using devices such as the NexGen burner recommended by the FAA. Therefore, with such assays, it is possible to assess the rates of thermal degradation as well as quantified pyrolysis gases. However, compared to other scales, there were very few works on a large scale. In addition, by focusing on the polluting nature of synthetic composite materials, there is also few research studies aimed at designing new polymer composite materials from biological sources.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Publication Date: 2021-10-28
    Description: Building an effective Machine Learning (ML) model for a data set is a difficult task involving various steps. One of the most important steps is to compare a substantial amount of generated ML models to find the optimal one for deployment. It is challenging to compare such models with a dynamic number of features. Comparison is more than only finding differences of ML model performance, as users are also interested in the relations between features and model performance such as feature importance for ML explanations. This paper proposes RadialNet Chart, a novel visualisation approach, to compare ML models trained with a different number of features of a given data set while revealing implicit dependent relations. In RadialNet Chart, ML models and features are represented by lines and arcs, respectively. These lines are generated effectively using a recursive function. The dependence of ML models with a dynamic number of features is encoded into the structure of visualisation, where ML models and their dependent features are directly revealed from related line connections. ML model performance information is encoded with colour and line width in RadialNet Chart. Taken together with the structure of visualisation, feature importance can be directly discerned in RadialNet Chart for ML explanations. Compared with other commonly used visualisation approaches, RadialNet Chart can help to simplify the ML model comparison process with different benefits such as the following: more efficient in terms of helping users to focus their attention to find visual elements of interest and easier to compare ML performance to find optimal ML model and discern important features visually and directly instead of through complex algorithmic calculations for ML explanations.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Publication Date: 2021-10-28
    Description: Increased behind-the-meter (BTM) solar generation causes additional errors in short-term load forecasting. To ensure power grid reliability, it is necessary to consider the influence of the behind-the-meter distributed resources. This study proposes a method to estimate the size of behind-the-meter assets by region to enhance load forecasting accuracy. This paper proposes a semi-supervised approach to BTM capacity estimation, including PV and battery energy storage systems (BESSs), to improve net load forecast using a probabilistic approach. A co-optimization is proposed to simultaneously optimize the hidden BTM capacity estimation and the expected improvement to the net load forecast. Finally, this paper presents a net load forecasting method that incorporates the results of BTM capacity estimation. To describe the efficiency of the proposed method, a study was conducted using actual utility data. The numerical results show that the proposed method improves the load forecasting accuracy by revealing the gross load pattern and reducing the influence of the BTM patterns.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Publication Date: 2021-10-29
    Description: Horizontal wells can significantly improve the gas production and are expected to be an efficient exploitation method for the industrialization of natural gas hydrates (NGHs) in the future. However, the near-wellbore hydrate is highly prone to decomposition during the drilling process, owing to the disturbance aroused by the factors such as the drilling fluid temperature, pressure, and salinity. These issues can result in the engineering accidents such as bit sticking and wellbore instability, which are required for further investigations. This paper studies the characteristics of drilling fluid invasion into the marine NGH reservoir with varied drilling fluid parameters via numerical simulation. The effects of the drilling fluid parameters on the decomposition behavior of near-wellbore hydrates are presented. The simulating results show that the adjustments of drilling fluid density within the mud safety window have limited effects on the NGH decomposition, meanwhile the hydrates reservoir is most sensitive to the drilling fluid temperature variation. If the drilling fluid temperature grows considerably due to improper control, the range of the hydrates decomposition around the horizontal well tends to expand, which then aggravates wellbore instability. When the drilling fluid salinity varies in the range of 3.5–7.5%, the increase in the ion concentration speeds up the hydrate decomposition, which is adverse to maintaining wellbore stability.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Publication Date: 2021-10-28
    Description: The use of hybrid renewable energy systems (HRES) has become the best option for supplying electricity to sites remote from the central power system because of its sustainability, environmental friendliness, and its low cost of energy compared to many conventional sources such as diesel generators. Due to the intermittent nature of renewable energy resources, there is a need however for an energy storage system (ESS) to store the surplus energy and feed the energy deficit. Most renewable sources used battery storage systems (BSS), a green hydrogen storage system (GHSS), and a diesel generator as a backup for these sources. Batteries are very expensive and have a very short lifetime, and GHSS have a very expensive initial cost and many security issues. In this paper, a system consisting of wind turbines and a photovoltaic (PV) array with a pumped hydro energy storage (PHES) system as the main energy storage to replace the expensive and short lifetime batteries is proposed. The proposed system is built to feed a remote area called Dumah Aljandal in the north of Saudi Arabia. A smart grid is used via a novel demand response strategy (DRS) with a dynamic tariff to reduce the size of the components and it reduces the cost of energy compared to a flat tariff. The use of the PHES with smart DRS reduced the cost of energy by 34.2%, and 41.1% compared to the use of BSS and GHSS as an ESS, respectively. Moreover, the use of 100% green energy sources will avoid the emission of an estimated 2.5 million tons of greenhouse gases every year. The proposed system will use a novel optimization algorithm called the gradually reduced particles of particle swarm optimization (GRP-PSO) algorithm to enhance the exploration and exploitation during the searching iterations. The GRP-PSO reduces the convergence time to 58% compared to the average convergence time of 10 optimization algorithms used for comparison. A sensitivity analysis study is introduced in this paper in which the effect of ±20% change in wind speed and solar irradiance are selected and the system showed a low effect of these resources on the Levelized cost of energy of the HRES. These outstanding results proved the superiority of using a pumped-storage system with a dynamic tariff demand response strategy compared to the other energy storage systems with flat-rate tariffs.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Publication Date: 2021-10-28
    Description: The liberalization of the gas market has deeply affected the structure of the gas system. The change from a vertically integrated utility structure to a liberalized architecture has resulted in a new network asset where aggregators could play a key role. To enable aggregators’ functionalities, the gas system has moved to a smart configuration. The development of this Advanced Metering Infrastructure (AMI) allowing a two-way communication between the utility and the consumers, together with demand response programs, prove to be an advantageous solution. Utilities are allowed to manage consumers’ gas load by asking them to reduce or shift their gas usage so that rebates or back payments could be available for consumers. In this framework, aimed at ensuring the feasibility of the gas system and promoting the aggregation of small gas loads, a new agent has been identified. In this research, the potential of district heating systems as gas market aggregators, together with a novel architecture for the gas network system has been identified. Furthermore, DR benefits in natural gas systems have been assessed with a focus on the Italian peninsula, where the authors have already carried out a previous analysis in this regard.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Publication Date: 2021-10-28
    Description: This study presents pro-ecological activities focused on an analysis of the use of biofuels as an environmentally friendly fuel. The research objects were different concentration mixtures of diesel fuel and fatty acid methyl esters, that is, transesterified plant oils. The tests involved an assessment of the performance parameters of a drive unit in a vehicle powered by diesel fuel for different mixtures of diesel oil and fatty acid methyl esters in the following proportions: 10%, 30%, 50% and 50% with chemical additives. The tests were comparative and were conducted for ‘pure’ diesel (ON). The study presents test results of selected performance parameters of the analyzed power unit. The object of the tests was a self-injection engine with a maximum power of 81 kW. The main tests which were most important for assessment of the mixtures, from the point of view of their effect on the analyzed performance parameters, involved measuring power and torque, and the toxic components of exhaust gases. Based on the obtained results, a statistical analysis was carried out, and a model for the evaluation of how the research object functions when fed with different fuel mixtures was developed. The research found which mixture can be considered the most optimal, and what the influence of individual fuel mixtures is on the analyzed performance parameters of the tested power unit.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Publication Date: 2021-10-28
    Description: By combining the advantages of different energy storage technologies, the hybrid energy storage system (HESS) can satisfy the multiple requirements of prosumer systems. However, the required capacity of the HESS is larger than that of the single-battery energy storage system (ESS). This paper investigates the energy exchange within the HESS caused by the phase shift of the low-pass filter controller and its relevant impact on the HESS. The results show that unnecessary energy exchange results in an oversized capacity and increased energy loss. In addition, the increase in the time constant of the low-pass filter controller leads to a larger phase shift, further contributing to the increases in the total capacity and energy loss. Furthermore, this paper compares the single-battery ESS, the battery-supercapacitor HESS, and the battery-flywheel HESS implemented in a household-prosumer system along with a renewable energy source (RES). The comparison of the ESS combinations demonstrates the differences between their power flows, the required capacities of their individual energy storage devices (ESDs), their energy losses, their battery lifetimes, and their project costs. The results indicate that techno-economic analysis should be performed carefully to select the appropriate ESS solution for specific household-prosumer systems.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Publication Date: 2021-10-28
    Description: In the case of the inductive voltage transformer (VT), the resonance phenomenon may be the main reason for its poor transformation accuracy of the non-sinusoidal voltage. This problem mainly results from the leakage inductance and the parasitic capacitance of its primary winding. The application of the sinusoidal voltage with a frequency from 20 Hz to 20 kHz presented in this study ensures proper identification of the resonance frequencies of the medium-voltage (MV) inductive VTs. The results are consistent with the values obtained in the reference condition at their nominal primary voltage. Therefore, it is proven that the proposed solution is effective in all cases. The influence of the main frequency variation of the non-sinusoidal primary voltage on the resonance properties of the inductive VT is also studied. Moreover, the tests indicate that the capacitance of the load of the secondary winding may cause a decrease in their resonance frequency.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Publication Date: 2021-10-28
    Description: Understanding the behaviour of gas–liquid flows in upward and downward pipe configurations in chemical, petroleum, and nuclear industries is vital when optimal design, operation, production, and safety are of paramount concern. Unfortunately, the information concerning the behaviour of such flows in large pipe diameters is rare. This article aims to bridge that gap by reporting air–water upward and downward flows in 127 mm internal diameter pipes using advanced conductance ring probes located at two measurement locations. The liquid and gas flow rates are 0.021 to 0.33 m/s and 3.52 to 16.1 m/s, correspondingly, covering churn and annular flows. To achieve the desired objectives, several parameters, probability density function (PDF), power spectral density (PSD), Slippage Number (SN), drift velocity (Ugd), and distribution coefficient (C0) were employed. The flow regimes encountered in the two pipe configurations were distinguished employing a flow regime map available in the literature and statistical analysis. The obtained results were supported by visual inspection. The comparison between the present study against reported studies reveals the same tendency for the measured experimental data. The Root Mean Square Error (RMSE) method within 4% was utilized in recommending the best void fraction prediction correlation for the downward and upward flows.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Publication Date: 2021-10-29
    Description: Apart from numerous technical challenges, the transition towards a carbon-neutral energy supply is greatly hindered by limited economic feasibility of renewable energy sources. This results in their slow and bounded penetration in both commercial and residential sectors that are responsible for over 40% of final energy consumption. This paper aims to demonstrate that combined application of sophisticated planning methodologies at building-level and presents incentive mechanisms for renewables that can result in prosumers, featuring hybrid renewable energy systems (HRES), with economic performance comparable to that of conventional energy systems. The presented research enhances existing planning methodologies by integrating appliance-level demand side management into the decision process and investigates its effect on the planning problem. Moreover, the proposed methodology features an innovative and holistic approach that simultaneously assess electrical and thermal domain in both an isolated and grid-connected context. The analyzed hybrid system consists of solar photovoltaic, wind turbine and battery with thermal supply featuring solar thermal collector and a ground-source heat pump. Overall optimization problem is modeled as a mixed-integer linear program, while ranking of all feasible alternatives is made by the multicriteria decision-making algorithm against several technological, economic, and environmental criteria. A real-life scenario of energy system retrofit for a building in the United Kingdom was employed to demonstrate overall cost savings of 12% in the present market and regulation context.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Publication Date: 2021-10-28
    Description: Solar still, a small equipment using evaporation and condensation processes to get clean water, is expected to be widely used for sea/brackish water desalination, water purification, and wastewater treatment because of its convenient carrying, friendly environment, and low energy consumption. In recent years, considerable progress has been made in improving the productivity of solar still. This paper will reclassify the methods to improve the solar still by elevating the evaporation rate and condensation rate. The main methods increasing evaporation rate are as follows: (i) adding heat storage materials; (ii) using nanoparticles; (iii) changing structure of the absorption plate; and (iv) using photothermal materials. The primary methods increasing the condensation rate are as follows: (i) cooling the condensing surface; (ii) increasing the condensation area; (iii) changing the wettability of the condensing surface; and (iv) using a separate condenser. The advantages and disadvantages of each method are compared. Furthermore, this paper includes an economic analysis of current solar stills and a forecast of future developments. The freshwater cost of solar still is in the range of about USD 0.0061–0.277/L, which provides reference and direction for future researching solar stills on their low cost and high productivity.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Publication Date: 2021-10-28
    Description: The radiation flux distributions produced by the concentrating solar systems used to produce thermal/electrical power are usually non-homogeneous. This results in non-uniform temperature distributions on the solar receivers, causing adverse effects on the system’s overall performance. An approach to better understand the problem is to study the surfaces around the focal zone where the radiation density is homogeneous (isosurfaces), generating them from experimental data. For this, it is necessary to superimpose built volumes of the different irradiance levels using parallel planes in different directions from the focal point of a concentrator. These volumes are known as effective volumes. This study presents the model used to generate effective volume produced by a point focus concentrator, comparing it with experimental results in a direction perpendicular to the focal axis. The effective volumes were developed considering a global optical error of the system of 2.8 mrad. The set of methods used to generate effective volumes has not been previously presented in the literature. The theoretical-experimental research consisted of the combination of the camera-target method and the simulations by the ray-tracing technique. The results showed effective volumes with the highest value of 10 MW/m2 and the lowest value of 4.5 MW/m2.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Publication Date: 2021-10-28
    Description: The main purpose of this study is to identify the drivers of sustainable performance in firms that operate in the energy sector. Under the assumption of bidirectional impacts, we empirically tested the trade-offs between sustainable and financial performance, in light of neoclassical theory, the natural-resources-based view, and instrumental stakeholder theory. We hypothesize that, in the energy sector, sustainable performance is positively associated with firms’ financial performance and that sustainability reporting is an important driver of sustainable performance. We add primarily by considering the relevance of sustainability-policy-oriented factors and revising the role of sustainability reporting within. We provide empirical evidence based on a large panel of firm-year observations within the 2013–2020 time span, for firms that operate in the energy sector and are located in Europe. We have found strong support for the positive link between sustainable performance (proxied with ESG score) and returns, which conforms to the assumptions of the natural-resources-based view. However, we have also found some evidence that more sustainable firms face greater costs input, which is considered in neoclassical theory. We have also confirmed no relevance of the slack-resources-based view. Finally, we found sustainability reporting to be the most influential among the set of sustainability-policy-oriented factors. This evidence demonstrates that stakeholders’ pressure on firms’ transparency could be an important driver of sustainable performance in the energy sector.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Publication Date: 2021-10-28
    Description: The determination of thermal structure functions from transient thermal measurements using network identification by deconvolution is a delicate process as it is sensitive to noise in the measured data. Great care must be taken not only during the measurement process but also to ensure a stable implementation of the algorithm. In this paper, a method is presented that quantifies the absolute accuracy of network identification on the basis of different test structures. For this purpose, three measures of accuracy are defined. By these metrics, several variants of network identification are optimized and compared against each other. Performance in the presence of noise is analyzed by adding Gaussian noise to the input data. In the cases tested, the use of a Bayesian deconvolution provided the best results.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Publication Date: 2021-08-09
    Description: Gas engine-driven heat pumps are an interesting option to satisfy space heating and cooling demands aiming at energy saving, environmental impact and operating costs’ reduction. This work presents (i) a comprehensive review updated on gas engine-driven heat pumps research activities, (ii) the investigation of the central role of this technology in the air conditioning sector and (iii) the future perspectives regarding gas engine heat pumps’ diffusion in the context of the energy sector decarbonisation. The outcomes highlight that gas engine heat pumps could have better environmental performance compared to electric heat pumps both in heating and cooling operations. Moreover, they could play a pivotal role in the fight against climate change and energy security since they can guarantee an energy mix differentiation moving from electricity to natural gas and renewable gases’ usage. Indeed, by 2030, a lower-carbon gas grid could be supported by renewable gases. A further investigation has concerned diffusion of gas heat pumps activated from biofuels produced by local biomass in an energy community scenario based on a low-temperature energy district network. A novel biomass-based GEHP interacting with a low-temperature district heating network is proposed here. This system could save more than 30% of primary energy compared to biomass-fuelled boilers.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Publication Date: 2021-06-07
    Description: Wine batch distillation in a copper pot still heated directly by combustion is unusual. It is a niche sector. Few studies are available on the subject and even fewer have studied it from a thermal point of view. In a context of ecology awareness and regularly increasing gas taxes, finding less energy consuming and more performing solutions has become necessary. Two methods already exist to recover energy for such pot stills, however improvements could be made. The present study focuses on the heating zone of an experimental pot still. First, a thermal diagnosis based on a nodal model is conducted in transient regime. The major sites of energy expenditure and waste are thus identified and quantified. Results highlight significant losses both in combustion smoke and by conduction to the environment resulting from a limited thermal performance of the system. Proposals are then made to enhance it. For instance, the preheating could be optimized and more thermal waste could be recovered.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...