    Entomologia experimentalis et applicata 34 (1983), S. 20-26 
    ISSN: 1570-7458
    Keywords: Dioryctria abietella ; Cone pyralid ; Lepidoptera ; Pyralidae ; Sex pheromone, (Z,E)-9,11-tetradecadienyl acetate ; Single sensillum recordings ; Electroantennography ; Gas chromatography ; Mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Résumé L'analyse en chromatographie gazeuse associée à une détection électroantennographique a montré que l'acétate (Z,E)-9,11-tétradécadiényle (Z,E)-9,11–14:Ac est l'un des composants de la phéromone de Dioryctria abietella Schiff (Lepid.: Pyralidae). Couplage chromatographie en phase gazeuse spectrometrie de masse a montré la présence d'acétate tétradécadiényle avec un spectre de masse et un indice de rétention identiques au Z,E-9,11–14:Ac Un récepteur cellulaire sensible à la fois au Z,E-9,11–14:Ac et à un extrait de la femelle a été identifié sous l'antenne du mâle. Les analyses des antennogrammes et de la cellule isolée ont étayé la caractérisation du composant de la phéromone comme étant Z,E-9,11–14:Ac. Un récepteur cellulaire additionnel sensible à l'acétate (Z.)-9-tétradécadiényle et à l'acétate (Z.E.)-9,12-tétradécadiényle a été trouvé sur l'antenne du mâle, mais il n'était pas activé par l'extrait de la femelle. Sur le terrain Z,E-9,11–14:Ac, présenté seul, attirait des nombres importants de mâles de D. abietella. L'addition de l'acétate (Z)-9-tétradécényle a inhibé l'attraction des mâles par les pièges.
    Notes: Summary Gas chromatographic analyses coupled with electro-antennographic detection indicated that (Z,E)-9,11-tetradecadienyl acetate (Z,E-9, 11–14:Ac) is a pheromone component of the cone pyralid Dioryctria abietella. Gas chromatographic-mass spectrometric analyses confirmed the presence of a tetradecadienyl acetate with mass spectrum and retention index identical to Z,E-9,11–14:Ac. A receptor cell sensitive to both Z,E-9,11–14:Ac and the female extract was identified on the male antenna. An additional receptor cell sensitive to (Z)-9-tetradecenyl acetate and (Z,E)-9,12-tetradecadienyl acetate was found on the male antenna but was not activated by the female extract. In the field Z,E-9,11–14:Ac presented alone attracted significant numbers of male D. abietella. Addition of (Z)-9-tetradecenyl acetate inhibited the attraction of males to traps.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Trees 1 (1987), S. 94-101 
    ISSN: 1432-2285
    Keywords: Monoterpenes ; Abies alba Mill ; Resin ; Seeds ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Summary Using gas-chromatographic methods, the variability of the contents of monoterpene hydrocarbons (α-pinene, β-pinene, Δ3carene and limonene) in the resin of silver fir seeds (Abies alba Mill.) was studied. Resin cavities were characterized according to their position on the seed surface. It was estabilished that the terpene content of the resin of cavities localized on the abaxialadaxial surfaces of the seed differs significantly, creating a gradient of resin composition around the circumference of the seed. The differences between various resin cavities of single seeds were greater than the differences between different seeds of a single cone and between seeds of various cones on a single tree. An accurate definition of the resin cavity location on the seeds appears to be a fundamental condition for the collection of a sample representing the resin composition of individual trees. Resin biosynthesis in the course of organogenesis and the control of terpene contents in the resin of various locations on the seed and the cone are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 269-284 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid chromatography ; Phenols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas and high-performance liquid chromatographic methods in the analysis of phenols are reviewed. Among the great number of phenolic compounds analyzed, alkylphenols, chlorophenols, dihydroxy- and trihydroxybenzenes and biphenols are chiefly considered. The advantages and drawbacks of the methods are discussed, quoting the most important work. Relationships between the structural characteristics of phenols, the stationary phase structure, the mobile phase composition and the retention data are treated. Typical examples of the conditions for GC and HPLC analysis are summarized in tables. The literature comprises over 270 references, most of them recent.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Average molecular polarizability ; Retention index ; Polycyclic aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The Kováts retention indices of 10 polycyclic aromatic hydrocarbons were determined on SE-30, OV-101, SE-52, OV-7 and OV-17 stationary phases. A significant correlation has been found between the retention indices and the average molecular polarizabilities of the analyzed substances. Equations were derived for the direct determination of the average molecular polarizabilities from the retention index values. The influence of the temperature on this relationship is also indicated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Esterification in aqueous solution ; iso butyl esters of C1–C20 fatty acids ; Gas chromatography ; Fatty acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary C1–C20 carboxylic acids have been esterified in aqueous solutions with i-butanol. Gas chromatographic analyses have been performed from a single chromatogram. It has been established that esterification in the concentration range of [H2O]/[i-BuOH]=0.01–10.3 can be utilized for the quantitative determination of these carboxylic acids. The presence of water does not interfere in the range of [H2O]/[i-BuOH]=0.01–1.03. In the cases of [H2O]/[i-BuOH]〉1.03, anhydrous sodium sulfate has been used for binding the water, in an amount of [Na2SO4]anh./[H2O]≥0.2.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 818-824 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Selective sampling ; On-line fractionation ; Essential oil analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The paper describes the possibilities of on-line selective sampling as an on-line fraction technique for the analysis of essential oils. Selective sampling is a micro-separation method, on-line with on-column injection, carried out directly in the syringe body by means of a selective elution of the sample through a fraction cartridge. The paper reports a method of both preparing and standardizing silica gel cartridges, and illustrates through some examples the results of some elution series of solvents on different essential oils.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Organic pollutants determination ; Gas chromatography ; Thermal desorption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The problem of the separation of 34 volatile organic chlorinated compounds is solved by using three different GC columns selected according to the needs of the particular separation required. The effect of water vapor contained as moisture in the trapped air on the retention of some characteristic compounds is studied. The influence of dead volumes on trap injection is also studied.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 888-892 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Calculation of temperature programmed ; Retention indices
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new method is presented for the calculation of the retention indices under linear temperature programming with or without an initial isothermal period. The data calculated by the method are in good agreement with the isothermal retention indices.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Esterification in aqueous solution ; n-Propyl esters of aromatic polycarboxylic acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The direct esterification and gas chromatographic analysis of aromatic carboxylic acids as n-propyl esters is described. Derivatization is performed in aqueous solution with n-propanol in the presence of sulfuric acid. The n-propyl esters of benzoic, phthalic, trimellitic and pyromellitic acids permit their gas chromatographic separation from each other and from fatty acids and aliphatic dicarboxylic acids. At mode ratios of [H2O]/[n-PrOH]≤0.03 the water present does not interfere with the esterification reaction. At mole ratios above 0.03 anhydrous sodium sulfate is used for binding the water, at mole ratios of [Na2SO4anh.]/[H2O]=0.51–1.52 and of [H2SO4]/[Na2SO4anh.]=0.43–1.28, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 195-198 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Structure-retention relationships ; Polarity parameters ; Retention index
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The possibility of evaluation of the parameters representing the dispersive solute-solvent interactions is presented. BN and Bs values can be used to describe the liquid phase polarity and to predict the retention indices of alcohols when the model polyxyethylene glycol dialkyl ethers and their sulphur analogs are used as stationary phases. The possibility of the first ionization potentials estimation is also presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Prediction of retention volume ; Porous polymers coated with liquid phases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new expression which permits the prediction of the net retention volumes in gas chromatography with column packings of coated porous polymers is reported. The porous polymers Chromosorb 101 and Chromosorb 102 were used as supports and squalane, Ethofat and Carbowax 20M as stationary phases at three different column temperatures of 80°C, 100°C and 150°C. Several organic compounds of various polarity were used as test compounds and the net retention volumes, VNtheor, have been calculated according to this new expression. The VNtheor values were compared with the experimental net retention volumes, VNexp, and it was found that the difference between these two values is dependent on the type of compound and column packing. Nevertheless, the elution order could be predicted in most cases.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 499-501 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Packed+capillary GC switching system ; Precolumn construction, oven and connector
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The constractional details of precolumns, its oven and connector have been given with two types of multiflow control modules. Two types of phases made in China, a silanized pellicular beads and a non silanized pellicular silica beads, with an optimum particle size of 20μm to 30μm were packed in the precolumn 20mm in length with the column efficiency of 4620 plates/meter at column temperature of 49°C. A 25m×0.22mm i.d. capillary column coated with bonded methylsilicone phase from Chrompack connected with the precolumn (250°C) has an efficiency of 5376 plates/meter for n-octane. But it decreased to 3149 plates/meter by decreasing the precolumn temperature to 130°C.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Immobilized Carbowax-type stationary phases ; Free fatty acids analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Capillary columns coated with acid-modified poly-(ethylene glycol)-type immobilized stationary phases have been studied. The thermostability and chromatographic behaviour of the columns and the stability of the coated films after washing with different solvents were investigated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Fourier transform IR detection ; Headspace sampling ; Solvents of abuse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary After experimental intoxication of rats, gas chromatography — Fourier transform infrared spectrometry with headspace sampling (HS/GC/FT-IR) was used to identify solvents of abuse in biological material (blood, liver, lungs and brain). Limits of detection were measured for acetone, 2-butanone, ether, toluene and trichlorethylene with standard solutions. All the solvents have been identified in the organs of the intoxicated rats. For blood samples a salting-out effect was obtained with potassium carbonate. HS/GC/FT-IR allowed the identification of metabolites of acetone (isopropanol) and of 2-butanone (2-butanol) in blood and organs.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Physico-chemical properties ; Retention indices ; Cycloolefins
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention indices of mono and polycycloolefins with endo or exo double bonds, on squalane or polypropylenglycol 425 are related to their physico-chemical properties such as boiling point, molar volume, molar refraction, and refractive index. Equations have been empirically obtained, from which accurate retention indices of these compounds can be predicted. Unknown boiling points of some of these compounds can also be calculated from their lineal relation with the retention index on squalane.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 839-843 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Stationary phases ; Porous polymer beads ; Polarity ; Adsorbents ; Breakthrough volume
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The breakthrough volume of ådsorbent traps made with porous polymer beads Porapak N, P. Q, R, S was evaluated by analysis of polarity reference substances proposed by Rohrschneider (ethanol, methyl ethyl ketone, nitrometane, benzene, pyridine) by McReynolds (butanol, methyl propyl ketone) and of the first term of some homologous series: alcohols, aldehides, carboxilic acids, nitrocompounds, iodoalkanes and nitriles. Adjusted retention times of the compounds were measured at 200°C and correlated with the physical properties and with polarity class according to Ewell. Trapping efficiency of the various Porapak types was evaluated and the theoretical breakthrough volumes at 25°C was calculated for the used test substances.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 850-855 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns ; Bacterial cellular fatty acids ; Stationary phase selectivity ; Solid phase preseparation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The importance of selectivity in the capillary gas chromatographic analysis of the cellular fatty acids of micro-organisms is underestimated. The analysis on apolar silicone phases can lead to erratic elucidation of the fatty acid structure. Qualitative errors have been detected in commercially available standards on which computer matching identification techniques are based. Using highly polar capillary columns of the cyanopropyl silicone type, the errors could be elucidated. The exact identification of the hydrolysis products of bacteria is a must for chemotaxonomic studies applying chromatographic techniques. The fatty acid methyl ester profiles can also contain other chemical components which are very important taxonomic markers. Fatty aldehydes, for example, are main components in someClostridium species. Fractionation techniques are described for selective enrichment of fatty aldehydes and hydroxy fatty acids.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 215-219 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid chromatography ; Thermodynamic equilibria ; Solution and adsorption thermodynamics ; Gas adsorption isotherms
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary After a brief recall of the chromatographic principles, the different applications of gas chromatographic measurements of thermodynamic equilibria were reviewed. Gas and liquid chromatographies are now well known and elegant methods for measuring the physicochemical properties and phase equilibrium thermodynamic constants. Although fundamentally a dynamical method and mostly known as a powerful separation technique, chromatography can be schematized by a sucession of equilbria of a chemical species partitioning between a mobile phase and a fixed liquid or solid stationary phase. It can be operated in either infinite dilution or finite concentration conditions and permits to collect a large number of data for calculating molecular interactions for solutes which are either rare or available at the trace level. Gas chromatography permits the measurement of gas adsorption isotherm, gas-liquid equilibria, molecular diffusion and interaction virials. The modelization of successive partition equuilibria occuring in the chromatographic column leads to rather simple expression of differential enthalpy, entropy, free energy of adsorption or solution, variation of heat capacity, complexation constant, second virial coefficients, gas-solid and gasliquid isotherm and also binary or ternary equilibria. The possibilities of High Performance-Liquid Chromatography to investigate adsorption from solutions and chemical equilibria are also discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 1 (1987), S. 157-173 
    ISSN: 0886-9383
    Keywords: Gas chromatography ; Simplex ; Barycentric co-ordinates ; Discriminant analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper proposes an elegant, yet straightforward, model for classifying linear mixtures. A linear mixture is defined as a random vector y in which the variable are a (non-negative) weighted average of corresponding variables, assumed to characterize g component groups. These weights are referred to as ‘mixing proportions’. The model seeks to identify the mixture constituents and estimate the mixing proportions. It is demonstrated within the context of high resolution gas chromatography and the problem of identifying the constituents in polychlorinated biphenyl mixtures.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Aqueous samples ; Direct injection ; Traces of ketones and halogenated hydrocarbons ; Environmental analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Procedures for the quantitative analysis of industrial effluents which involve concentration by solvent extraction or the purge-and-trap method are time-consuming, labor-intensive, and prone to error. Direct aqueous injection gas chromatography using an electron-capture detector for the analysis of volatile halocarbons at the ppb level is in routine use in many laboratories. We now discuss the development of a similar protocol for the analysis of volatile polar organics such as acetone, methyl ethyl ketone, methyl isobutyl ketone, and tretrahydrofuran using a flame-ionization detector.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Nitrogen-specific detector ; Flash methylation ; Barbital and pentobarbital ; Blood analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A sensitive and simplified method is described for the determination of barbital (B) and pentobarbital (PB) in blood using gas chromatography with a nitrogen-specific flame ionization detector. After a simple one-step extraction, B and PB were reconstituted in trimethylanilinium hydroxide and introduced directly into the gas chromatograph. Lower limits of detection was 0.14 μg/ml for B and PB in either water or blood solutions. The recoveries for B from water and blood were 90 and 88%, respectively; for PB they were essentially complete. The average between-run and within-run coefficients of variation for B from water and blood were lower than 7.8%, whereas those of PB were lower than 3.0%. The scale and sensitivity of detection for B and PB were found to be suitable for use in pharmacokinetic studies in the rat.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 423-426 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Complexation ; Mercaptosilane chemically bonded phase ; Transition metal complexes ; Olefinic π-complexes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A column packing containing thiol groups chemically bonded to the silica surface was synthesized. The thiol functional groups were used as ligands capable of forming stable complexes with Cu(II). The prepared material was characterized by gas chromatography using unsaturated linear and branched hydrocarbons as well as cyclic and aromatic hydrocarbons. The occurrence of specific metal—olefin interactions resulting from the formation of π-complexes during the chromatographic process was observed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Backflushing, peak-cutting technique ; Trace analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A backflusing, peak-cutting method was developed for the analysis of trace components present in the tail of a major component peak. Using a helium-ionization detector, the minimum detectable concentration (MDC) was: oxygen in hydrogen, 0.5ppm; nitrogen in oxygen or argon, 1ppm; and methane and carbon monoxide in nitrogen, 1ppm. The corresponding MDC values for the conventional single-column method were 7.2ppm, 8.3ppm, and 14 and 5ppm, respectively. Equations used to predict the retention time are given. The accuracy of the predicted retention time is about two percent compared to experimental results.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Alkylthiazoles ; Energy contributions of the alkyl groups ; Retention indices
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Retention indices and their energy equivalents were determined for ten alkylthiazoles analysed on the stationary phases Apiezon L, Triton X-305 and Carbowax 1000. It was found that the energy contributions of identical alkyl groups to the partial molar free energy of sorption of a molecule are not equivalent. Smaller energy contribututions are due to the α-position of alkyl groups with respect to the heteroatoms in the thiazole ring (α-effect). This effect was most pronounced for 2-alkylthiazoles. Higher sorption energies were found for dimethylthiazoles with two methylgroups in a vicinal position. The retention indices were predicted for ten other di- and tri-substituted methyl, ethyl and propyl thiazoles on the basis of the so-called α- and ortho-effects. The predicted values are in good agreement with the experimentally determined values.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 33-36 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Preparative scale chromatography ; Capacity ; Dual-step separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The capacity of dual-step preparative chromatographic separation systems is considered. It is shown that dualstep separation makes it possible to enhance the capacity of preparative installations as compared with single- and dual-stage purification of the compounds.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 44-46 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Natural gas analysis ; Poropak N
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple gas chromatographic method is described for the rapid analysis of natural gas using thermal conductivity detectors and programmed-temperature operation of a single Poropak N column. The method permits the determination of nitrogen, carbon dioxide and hydrocarbons containing one to seven carbon atoms.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 553-559 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Immobilized liquid phases ; Thick-film columns ; Diffusion coefficients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The influence of the liquid phase film thickness in open-tubular (capillary) columns on the individual resistance-to-mass-transfer terms and on the overall column efficiency is examined from the theoretical point of view. Methods for the calculation of the diffusion coefficients are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Immobilized liquid phases ; Thick-film columns ; GC-FTIR
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The performance of a column prepared with an immobilized (chemically bonded) methylsilicone phase having a film thickness of 5μm is investigated in detail. Due to their high sample capacity, such columns are particularly useful when directly coupling gas chromatography with spectroscopic techniques such as Fourier-transform infrared spectroscopy. Thick-film columns can even be used with thermal conductivity detectors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 600-604 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Alkyl benzenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The additivity concept in the retention index system of Kovats has been examined for a series ofn-alkylbenzenes and theiro- andp-monosubstituted nitro-, amino-, and chloro-derivatives. Anomalous behaviour is exhibited by the first three members of the series on both polar and non-polar stationary phases. For addition of a methylene group ton-propylbenzene or ap-substituted derivative, it is found that the retention increment, Δl CH2, approaches 100 units. However, the strong inductive effect of the group in the ortho position and the steric effects apparent in ano-substituted alkylbenzene lead to large variations of retention increment upon addition of-CH2-to the alkyl chain. A study ofn-alkylbenzene retention on Apiezon L and Carbowax 20M over a wide range of temperatures has verified the linearity of the retention increment with temperature and has revealed that this gradient increases with increasing carbon side-chain length for the first few members of the series, thereafter becoming constant. Functional retention increments, Δlx, for substitution of nitro-, amino- and chloro-groups into the benzene ring are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 691-692 
    ISSN: 1612-1112
    Keywords: Dichlorophenol isomers ; Sodium benzenesulfonate ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary It is difficult to separate all the dichlorophenol isomers as free phenols by gas-liquid chromatography. However they were effectively separated on 4,4′-dimethoxyazoxybenzene (liquid crystal), and all the isomers were separated appreciably well on sodium 1-naphthalenesulfonate, 2-naphthalenesulfonate and dodecylbenzenesulfonate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 65-69 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Oxygenates ; Fused-silica capillary columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method of analysing gasolines that contain oxygenates has been developed. The method uses a single fusedsilica capillary column and gives quantitative data for the oxygenates and the hydrocarbons in one analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Trace analysis ; GC-concentration ; Enrichment factor ; Theoretical evaluation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Based on gas chromatographic retention data obtained on a given adsorbent and at a given trap efficiency at different temperatures new equations are proposed for the evaluation of the enrichment factor. These equations are suitable under various preconcentration conditions such as: equilibrium saturation, complete trapping and permissible losses. Compared to known expressions for the evaluation of the enrichment factor the equations suggested consider the band broadening of the impurity in a trap causing a loss of the substance at the adsorption stage and dilution of the sample during desorption when the desorbed impurities are directed into the gas chromatographic column without intermediate freezing out in an graphic column without intermediate freezing out in an empty tube. The new equations may be used to select the optimum preconcentration conditions providing the necessary sensitivity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 191-194 
    ISSN: 1612-1112
    Keywords: Thermal treatment of MgO and MgCO3 ; Adsorption properties ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The changes in the chromatographic properties of MgO and MgCO3 due to thermal treatment was investigated. The experimental results show that thermally treated MgO and MgCO3 can be used as stationary phase for the gas-adsorption chromatography of hydrocarbon mixtures.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 418-420 
    ISSN: 1612-1112
    Keywords: Separation of metal chelates ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A very good separation of the acetylacetonate of AL-(III), Cr(III) and Co(III) has been obtained by gas chromatography, on a column containing OV-17 silicone oil as the stationary phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 421-425 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Purge and trap sampling ; Cryogenic focussing ; Water analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The most important operating parameters of a commercial purge and trap GC apparatus have been investigated. Band broadening problems arising from the slow desorption of compounds from the Tenax trap have been overcome by cryogenic focussing at the beginning of the column. Good results have been obtained with both packed and capillary columns. The sensitivity of the technique is sufficient to detect benzene in water at concentrations below 1μg kg−1 (1 ppb).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carbohydrate TMS-ethers ; Tautomeric equilibrium mixtures of aldoses ; MS and NMR identification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Equilibrium tautomers of aldopentoses (arabinose, ribose, xylose and lyxose) and aldohexones (allose, altrose, gulose, idose and talose) have been analyzed as their trimethyl-silyl ethers by capillary GC. Pentoses were separated on SE-54 and hexoses on OV-225. The four components of the tautomer equilibrium mixture have been identified using GC/MS and NMR data.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 722-726 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Adsorbents for gas chromatography ; Strong adsorption sites ; Heterogeneity of silica surface
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple gas chromatographic method is presented for the determination of the quantity of the strongest adsorption sites on an adsorbent's surface. The method consists of the blockage of the sites with quasi-irreversibly adsorbed, known amount of a strongly interacting compound and subsequent measuring of the retention of a hydrocarbon during the presence of the blocking compound in the column. Heterogeneity of chromatographic grade silicas is investigated with this method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Esterification in aqueous solution ; n-Propyl esters of aliphatic hydroxy acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Aliphatic hydroxy acids were esterified in aqueous solution in the presence of different amounts of sulfuric acid. Esterification of lactic, tartronic, malic and citric acids in water/n-propanol mixtures with mole ratios between 0.03 and 2.15 can be utilized for the determination of these acids by gas chromatography. Water does not interfere at water/n-propanol mole ratios below 0.03. For mole ratios above 0.03 anhydrous sodium sulfate is used for the binding of water. The mole ratio range was 0.24–2.13 for anhydrous sodium sulfate/water, and 0.16–1.28 for sulfuric acid/anhydrous sodium sulfate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Gas chromatography ; Bonded silica ; Residual silanol groups
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Silanol groups of chromatographic material surfaces were determined by chemical reaction with methyl-lithium. Evolved methane was measured by a gas chromatographic method using a column packed with molecular sieves. This chromatographic technique leads to very reproducible results, particularly for the control of the hydroxylation of a silica gel and for the analysis of residual groups at the surface of bonded silica.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 790-795 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Capillary columns in series ; Variable polarity columns ; Essential oils analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary By connecting capillary columns of different polarity in series and by changing the temperature program gradient, a system of variable polarity is obtained. The working conditions can be adjusted to optimize separations of complex mixtures. Application to the analysis of essential oils of: lavender, thyme, lemon petit grain, bergamot, and tangerine, are reported.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 240-242 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Stillingia oil ; Quantitative lipid analysis ; Chinese tallow,Sapium sebiferum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Contemporary stillingia oil from China is qualitatively similar to the oil described earlier, but it exhibits significant quantitative differences reflecting a degree of autoxidation of the unsaturated fatty acids either before or after crushing of the seeds.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Chemically bonded phases ; Specific interactions ; Chloroderivatives of alkanes and alkenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Interactions of Cu(II) complexes chemically bonded to the surface of silica with chloro-derivatives of alkanes and alkenes were investigated. It was found that chlorine as a substituent exerts a considerable influence on the retention of the individual chloro-derivatives. In the case of chloroalkenes this influence is negative while in the case of chloroalkanes it is positive. The magnitude of the observed effect depends on the number of substituents and on the way of their distribution within the molecule.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 286-288 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Macroporous copolymers of 2-hydroxyethyl ; methacrylate ; Graft polymers ; Polar sorbent for gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas chromatographic behaviour of crosslinked macroporous 2-hydroxyethyl methacrylate grafted with 2-methyloxazoline was investigated and the range of applicability of the copolymer was assessed. Retention index values were measured on this copolymer and compared with those obtained on the terpolymer 2-hydroxyethyl methacrylate-ethylene dimethacrylate-acrylonitrile. Rohrschneider constants and efficiency data for selected sorbates are given. The use of this type of polymer in the separation of various types of compounds is documented by various examples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 50-52 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention indices ; C6 alkanols ; OV-101 ; Carbowax 20M
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatographic retention indices for 16 C6 alkanols measured on capillary columns coated with OV-101 methylsilicone and Carbowax 20M propylethyleneglycol liquid phases at 80° and 90°C were determined. The respective standard deviation values were 0.5 and 0.8 i.u. The correlation between the retention indices measured on non-polar and polar stationary phases and the boiling points of the alkanols was studied.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 241-243 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Detectors ; Flame ionization detector ; History of chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary On the occasion of the 25-year anniversary of its invention, this article summarizes the events which led to the development of the flame ionization detector.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    ISSN: 1612-1112
    Keywords: Esterification in aqueous solution ; n-Butyl esters of fatty acids ; Gas chromatography ; Fatty acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The esterification of C1−C8 fatty acid in aqueous solutions and in the presence of sulfuric or hydrochloric acid and with n-butanol is described. It has been established that the esterification can be used for the quantitative determination of these fatty acids in the concentration ratio range of [H2O]/[n-BuOH]=0.01–5.3. In the concentration ratio range of 0.01–0.8 the water present does not interfere. In the concentration range of above 0.8 anhydrous sodium sulfate is used for binding the water, in the amount of [Na2SO4.anh.]/[H2O]≥0.2.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 472-476 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid stationary phase ; Liquid phase bleeding
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The theory of the evaporation of the liquid stationary phase is elaborated and experimentally verified. On the basis of this theory the role played by the losses in the amount of liquid phase present is quantitatively determined. General techniques are examined which minimize the losses; these techniques are based on saturating the incoming carrier gas with liquid phase vapours and raising the pressure of the carrier gas in the column, e.g. by connecting a capillary to the column outlet in order to offer resistance to the gas flow. The application of these techniques ensures stable performance of the gas chromatographic columns using a volatile liquid phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 53-54 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Dual-column system ; Thermal conductivity detector ; Anesthetic gas mixtures
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple dual-column system with a thermal conductivity detector is described, that can be used for the quantitative analysis of anesthetic gas mixtures of halothane (2-bromo-2-chloro-1,1,1-trifluoroethane), nitrous oxide and oxygen. The separation was performed on a Carbopack (SP 1000) column and a Porapak Q column arranged in series across the detector.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 132-136 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Column liquid chromatography ; Thin-layer chromatography ; Analysis of lactulose in carbohydrate mixtures
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Lactulose is a disaccharide with important implications in medicine, nutrition and dairy technology. It has to be determined usually as a minor component in complex matrices containing many other sugars. This paper describes the different chromatographic techniques (planar, liquid and gas chromatography) which have been proposed for the separation and quantification of lactulose in mixtures with other carbohydrates; the advantages of each technique are compared and some features where more research is necessary are outlined.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 169-170 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Packed column ; Immobilized silicone stationary phases ; Ozonization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Immobilization of silicone stationary phases, OV-1701 vinyl and OV-225 vinyl, on Chromosorb W-AW support was achieved in a simple procedure using ozone as an initiator. A column efficiency of 2400 theoretical plates/meter was obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 3-6 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Allyl bonded phases ; Addition Reactions ; Synthesis of new bonded phases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The presence of the double bond on the allyl moiety has been utilized as a site for addition reactions which could produce new stationary phases. Bromination and hydrobromination reactions have been employed to prove the feasibility of making modifications to the allyl bonded phase. Both retention volumes and thermodynamic parameters for the solutes studied change upon conversion to one of the brominated phases. Sample size studies are consistent with a bonded phase adsorption mechanism. FTIR spectra also confirm the modifications which have occurred on the allyl bonded material.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 265-268 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Dicarboxylic acid analysis ; n-Propyl esters of C2−C16 dicarboxylic acids ; Esterification in aqueous solution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary C2−C16 dicarboxylic acids were esterified in aqueous solution in the presence of sulfuric acid. Esterification in water/n-propanol mixtures with mole ratios between 0.03 and 2.21 can be utilized for the quantitative determination of dicarboxylic acids by gas chromatography. The presence of water does not interfere at water/n-propanol mole ratios below 0.45. For mole ratios above 0.45 anhydrous sodium sulfate has been used for binding the water. The mole ratio range tested was 0.12–0.99 for anhydrous sodium sulfate/water, and 0.16–2.55 for sulfuric acid/anhydrous sodium sulfate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 487-491 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Packed+capillary GC switching system ; Column efficiency utilization ratio ; New packed precolumn
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary To match the need of high efficiency capillary column (plate number N2, Plate height H2 and carrier gas linear velocity U2), a new high efficiency packed column (N1, H1 and U1) at high carrier gas velocity with small capacity factor has been developed in the light of theoretical discussion of factors effecting the column efficiency utilization ratio.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 492-498 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Packed+capillary GC switching system ; Accurate system quantitation ; Analysis of complex samples or dilute solution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A packed column containing immobilized SE-54 liquid phase on pellicular silica beads ZIPAX and having a high efficiency and high mass transfer rate has been successfully used in a two-dimensional packed+capillary column system without a cold trap. The application of this system is demonstrated by the analysis of C6-C8 aromatic hydrocarbons and lowboiling hydrocarbons present in natural oils, and of highboiling components present in low concentrations in a low-boiling solvent.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    ISSN: 1612-1112
    Keywords: Gas chromatography ; FT-IR detection ; γ- and δ-Haloesters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The decomposition of γ- and δ-haloesters has previously been observed to take place within a commercial GC/FT-IR light-pipe system. Using a home-built light-pipe interface, an analysis of this same class of compounds was conducted from which the source of the decomposition was determined to be a brass fitting central to the commercial system's assembly. It is proposed that the reaction is due to a weakening of the carbon-halogen bond by metal interaction thereby allowing lactonization to occur.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 36-37 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Cryogenic focusing ; On-column, pre-column trapping ; Volatile aroma compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 40-42 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Splitless Injection ; Drug analysis ; Concentration dependence of retention values ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 42-44 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Mg(NO3)2 .6H2O as stationary phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 60-63 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Cold silanization ; Medium polarity columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Silane-coupling agents, commonly used for fiberglass reinforced plastics (FRP), were applied for deactivation of silanol sites in glass capillary columns prior to coating with mediumpolarity phases such as Carbowax and Superox. The columns, prepared in a two-stage process in the case of glass (acidic leaching and drying, dynamic cold silanization followed by static coating with the phase) or a one stage process in the case of fused silica, gave the best results when deactivation and hence wettability were induced by glycidoxypropyltrimethoxy silane.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Residue analysis ; Fenvalerate ; Fabric protectant ; Woolen cloth ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for the determination of fenvalerate (cyano(3-phenoxyphenyl)methyl 4-chloro-α-(1-methylethyl)-benzeneacetate) residues on woolen cloth. The fenvalerate was Soxhlet-extracted from the treated fabric with acetone for four hours at a reflux rate of six solvent exchanges per hour. The fenvalerate residue was determined by gas-liquid chromatography with a flame ionization detector. The results were quantitated by comparing integrator counts obtained from extracts of treated samples with those obtained from known standards. The method was sensitive to 0.00054% fenvalerate by weight. Recoveries from fabric treated with 0.00054% to 0.215% averaged 94.8%. The response of the detector was linear over a 400-fold range of fenvalerate concentrations.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 273-274 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Solvent effect ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 269-272 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Retention indices ; Specific retention volumes ; n-Alkanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The choice of stationary phase for gas chromatography is dictated by the nature of the analytes. Polarity and selectivity are known to play an important role. This paper suggests equations for calculation of specific retention volumes of any compounds from their retention indices.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 366-370 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary column ; Chiral phase ; Amino acid enantiomers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Heliflex Chirasil-Val, a modified form of the original Chirasil-Val phase coated on fused silica capillary, has been investigated with regard to its resolution efficiency and the separation profile for various enantiomeric derivatives of amino acid. The best results could be obtained with TFA-Et derivatives by reason of the relatively low column temperature required.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 386-387 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; On column injection ; Movable injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 388-389 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary micro-packed columns ; Separation characteristics ; Application ; Separation of hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 392-393 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Hydrogen carrier gas ; Pt-Ir tubing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 390-391 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Dispersive interactions ; Inductive interactions ; Polycyclic aromatic hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 567-568 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Solvent effect ; Headspace analysis ; Trace analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 4-10 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Ion mobility detector ; Plasma chromatography ; Selective detection ; Quantitative analysis ; Halogenated compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An ion mobility detector that has been specifically developed for interfacing with capillary gas chromatography is investigated in the negative ion mode. Like the electron capture detector, to which this instrument is closely related, the ion mobility detector shows an enhanced response to low molecular weight halogenated compounds when a small quantity of oxygen is doped into the make-up gas flow. Under O2 doping conditions, the device can operate in a reactant ion monitoring mode responding universally to compounds capable of capturing thermal electrons and in a tunable selective product ion mode providing increased selectivity over that achieved by the ECD. At an oxygen concentration of 0.5%, minimum detectable amounts as low as 600 femtograms have been realized for carbon tetrachloride. Selectivity of chloro- versus bromo- compounds is demonstrated using a mixture of p-dichlorobenzene and p-dibromobenzene.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 11-15 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; ECD ; Halocarbons in water, 0.1-10 ppb ; 0.5-2 μl injected on-column ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Interest in monitoring halogenated organics in drinking water and natural surface and ground water in the low ppb range continues to grow. There is a tendency to include still more volatile halocarbons, the trace determination of which is known to be rather demanding. This prompted us to re-examine the feasibility of large-volume direct aqueous injection onto capillary columns, coupled with ECD. A primary problem was to avoid simultaneous elution of water with halocarbons, since water suppresses the ground current of the ECD. The following measures contributed to the solution of this problem.Apolar, extremely inert, columns are required to elute water completely, and even before very light halocarbons. Their coatings have to be far thicker (≍ 5 mUm) than commonly employed thick films since they must permit isothermal analysis at a column temperature around 100°C in order to ensure rapid and complete elution of water. Finally, it is essential that sampling be carried out on-column for two reasons: diffusion of water vapor in the injector, resulting in delayed elution, is then eliminated, and peak distortion during splitless injection is avoided.Although we now know that persilylated columns with immobilized coatings withstand routine water injections, more longterm experience is needed to provide detailed recommendations for the handling of these columns.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 34-35 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Samples with varying water content ; Retention times correlated with water content ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 213-215 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; HPLC sample work-up ; Valeriana celtica L ; Essential oil ; Nepetalactone, isovaleric acid ; Feline attractant ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 228-231 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Sample introduction ; Splitless injection ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 232-235 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Inlets ; Solvent effect ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Dynamic versus static leaching ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: It is well known that removal of metal ions from the glass surface greatly improves both the thermal stability and the adsorption characteristics of glass capillary columns. Usually metal ions are removed from a glass surface by acid leaching; in particular, the static leaching procedure with hydrochloric acid is used very often for the preparation of glass capillary columns. This paper discusses the results of an investigation into dynamic leaching. Special attention is paid to those factors which affect the adsorption properties of the leached surface. The importance of the non-specific adsorptivity of the capillary surface due to changes of surface properties induced by the leaching process is pointed out.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 241-246 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Cobalt-60 gamma radiation ; Immobilized phase ; Crosslinking ; Column activity ; Temperature Stability ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused silica capillaries deactivated with D4 and coated with OV-1 were subjected to cobalt-60 gamma radiation in order to elucidate the effect of incident radiation on column performance. The chromatographic performance of these open tubular columns in which OV-1 was polymerized in situ was found to be dependent on the dosage of radiation and was evaluated before and after the irradiated columns were rinsed with solvent. Of the radiation dosages employed, 3 MRad produced superior chromatographic performance coupled with very favorable residual surface activity.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 247-254 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Screening for basic drugs with retention indices differing by only four units ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary columns offer the toxicologist several advantages over packed columns. We have presented a highly reproducible screening procedure based on the retention index system and have shown the use of capillary columns for routine quantitation. We are currently expanding the use of these columns in our laboratory and predict that they will be in routine use by most toxicologists in the near future.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 255-263 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass, fused silica ; Two-dimensional technique ; Residue analysis in food ; Organophosphorus pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two-dimensional gas chromatography with two capillary columns of different polarity (SP 2100 and OV 225) is used for pesticide residue analysis in food samples. By means of “live chromatography” applying pneumatic switching technique according to Deans, unequivocal identification of 57 organophosphorus pesticides in food samples is achieved at trace concentrations. The instrument is equipped with only one injection port and one flame photometric detector. On-line data processing is very helpful, especially in calibration and checking the system's reliability with the multitude of test compounds. The complete pesticide residue analysis including clean-up of about six food samples can be completed by one person in 8 hours.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 422-426 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Stationary phase, polar ; DEGA ; Residue analysis of pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Polydiethylene glycol adipate (DEGA) has been successfully used as stationary phase for residue analysis by glass capillary gas chromatography. A specially stabilized version of the phase yields a good polar column which is stable up to 250°C when used in temperature programmed cycles. The paper lists 90 pesticides that have been successfully chromatographed in ng quantities on a DEGA column.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 436-440 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Superox-4 pretreatment, deactivation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 442-443 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Cyclodextrin polymer beads ; Double retention mechanism ; Interaction energy ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 444-445 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Open-tubular columns ; Reduced diameter ; High pressure ; Coating reservoir ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 497-500 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, fused silica ; On-column injection ; Solvent polarity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 501-504 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Van Deemter curves ; Thick film columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 504-507 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Effluent splitting ; Polyimide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 101-103 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; GC/MS ; Drugs of abuse ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 317-319 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, fused silica ; Drug screening ; Fused silica capillary column ; Toxicology ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 319-321 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Supercritical fluid chromatography ; Small diameter capillary columns ; Static coating at elevated temperature ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 328-332 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica (capillary) columns ; Bonded (cross-linked ) phases ; Hydrocarbon analysis ; Retention index data ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 448-450 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Solute focussing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 480-487 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Residue mixtures ; Inlet characteristics ; Injection procedure ; Repeatability ; Linearity ; Quantification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Residue mixtures of pesticides in foods which were difficult to separate by packed-column gas chromatography were determined by capillary gas chromatography and electron capture detection. Manual injections of sample and reference standard were made with a 10 μL syringe on a septum-enclosed, split/ splitless inlet system. Optimal peak height repeatability (± 3%( was achieved with three-μL injections which were made within time periods of four hours or less. The average linearity coefficient (slope( obtained for detector response as a function of solution concentration was 1.1.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 507-509 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, glass ; GC/MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns, glass ; Polyalkyleneglycol ether phases ; Inert columns ; Immobilization by condensation ; Methyltrimethoxysilane, coupling agent ; Trifluoroacetic acid, catalyst ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Using UCON 50 HB-5100, one of the most successful stationary phases in capillary gas chromatography during the past decade, as an example, we wish to redirect attention to the excellent properties of the polyethylene/polypropyleneglycol ether copolymer coatings. Based on experience gained in work with OH-terminated polysiloxanes, a method is described for preparing inert and relatively temperature stable chemically bonded and crosslinked coatings in a single working step. Methyltrimethoxysilane was used as coupling agent, and trifluoroacetic acid was introduced as an acidic catalyst. The reaction mechanisms involved as well as the influence of additional crosslinking on the column behavior are discussed, particularly with respect of the inertness of the coatings.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 97-99 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns glass ; Tetronic, stationary phase ; Inert column ; Irganox 1010 ; Antioxidant ; Catalyst ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 623-624 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 621-622 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Multiplex GC ; Vacancy chromatograms ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 680-682 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary column ; Split injector ; Herbicides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 41-42 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; PCDD's ; PCDF's ; Adsorption phenomena ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 77-81 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Liquid crystalline stationary phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Liquid crystalline polyacrylates (LCPAs) are evaluated as stationary phases for capillary gas chromatography (CGC). Aromatic hydrocarbons as well as polar isomeric compounds are used as test solutes to compare the polarity of the LCPAs with a conventional polysiloxane column and a Carbowax 20M column. The relative polarity of the columns with respect to change in the lateral and terminal substituents is also discussed. Lateral substitution, polarity of the terminal group, together with the solute size, affect the LCPA selectivity.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    ISSN: 0935-6304
    Keywords: Trace analysis ; Gas chromatography ; Solvent effect ; Inlet ; Injector ; Sampling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A sampling system for high resolution gas-liquid chromatography, based on the dynamic solvent effect, is described. Volatiles are accumulated off-line in a concentrator/injector and delivered to the column using an on-line inlet. Volatiles may be accumulated from gaseous or liquid matrices; they may be transferred to these by gas sparging or solvent extraction of any type of sample. The sampling technique is quantitatively precise; e.g. coefficients of variation of peak percentage areas better than 5% for a range of solutes at a concentration of 2:107. Examples of the application of the sampling system are presented.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...