Publikationsdatum:
2019-07-13
Beschreibung:
The present investigation is concerned with the applicability of the vertical temperature gradient, DT, as a dispersion parameter for urban area sources. Data on DT were tabulated from temperature measurements at 5 m and 30 m obtained on 30 m towers at 12 stations. DT was obtained by subtracting the value at 5 m from that at 30 m. Positive DT values represent an inversion. Accuracy of the DT data is 0.1 K. Hourly measurements of DT along with concentrations of the primary pollutants, CO, NO, and total hydrocarbons (THC), are available from the 1976 RAPS data base for St. Louis. Linear correlations between a given pollutant species concentration and DT are developed from that data set. It could be confirmed that a strong positive correlation exists at night between the thermal stability of the lowest part of the boundary layer and the urban concentration of the primary pollutants CO, NO, and hydrocarbons.
Schlagwort(e):
ENVIRONMENT POLLUTION
Materialart:
Joint Conference on Applications of Air Pollution Meteorology; Jan 11, 1982 - Jan 15, 1982; San Antonio, TX
Format:
text
Permalink