ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 79 (1983), S. 95-108 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A method for the chloride trace determination in different samples dissolved in water is described. An isotope dilution technique with a37Cl spike and the production of negative thermal ions in a mass spectrometer are used. In different samples of distilled water the chloride content is determined down to the lowest ppb range. A procedure to purify super pure hydrofluoric acid from chloride is described. From the pure chemicals KBr, NaI, K2SO4 and NaNO3 the chloride contents in the range between 1 and 380 ppm are analysed. In the case of KBr and KI no interference of the halide matrix elements with the chloride measurement takes place. Analysing KBr and NaI chloride is separated by a strongly basic anion exchanger, for K2SO4 and NaNO3 a precipitation of AgCl is used for separation.
    Notes: Zusammenfassung Eine Methode zur Spurenbestimmung von Chlorid in verschiedenen gelösten Proben wurde beschrieben. Dabei wurde eine Isotopenverdünnungstechnik mit einem37C1-Indikator sowie die Erzeugung negativer Thermionen in einem Massenspektrometer benutzt. In auf verschiedene Weise hergestellten Proben von dest. Wasser wurde der Chloridgehalt bis in den untersten ppb-Bereich hinein analysiert. Ein Verfahren zur Chloridreinigung von suprapurer Flußsäure wurde beschrieben. In den Reinstchemikalien KBr, NaJ, K2SO4 und NaNO3 wurden Chloridgehalte von 1–380 ppm bestimmt, wobei auch bei den Analysen in einer Halogenidmatrix keine Störung durch diese Matrixelemente erfolgte. Bei der KBr-und NaJ-Probe wurde Chlorid über einen stark basischen Anionenaustauscher, bei K2SO4 und NaNCO3 durch AgCl-Fällung abgetrennt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 306 (1981), S. 245-251 
    ISSN: 1618-2650
    Keywords: Best. von Bromid in Chemikalien ; Massenspektrometrie/Isotopenverdünnungsanalyse ; negative Thermionisation, Reinchemikalien
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Entwicklung einer massenspektrometrischen Isotopenverdünnungsanalyse zur Bromidbestimmung wird beschrieben. Dabei werden in einer Zweiband-Ionenquelle negative Thermionen erzeugt. Die Abhängigkeit der Br−-Ionenstromintensität und des gemessenen79Br/81Br-Verhältnisses von Ionisierungsbandtemperatur und -material sowie von der chemischen Probenform wird untersucht. Mit Re-Bändern und AgBr als Probensubstanz werden relative Standardabweichungen der Bromisotopenverhältnismessung von 0,08% erreicht. In verschiedenen Chemikalien werden Bromidspurengehalte im Bereich von 1,3 ppb bis 136 ppm mit relativen Standardabweichungen zwischen 1 und 15% bestimmt. Dabei erfolgt die Bromidabtrennung entweder über eine Anionenaustauschersäule oder durch Ausfällung als AgBr.
    Notes: Summary The development of a mass spectrometric isotope dilution analysis for bromide trace determination is described. Negative thermal ions are produced in a double-filament ion source. The Br− ion beam intensity and the measured79Br/81Br isotope ratio in dependence on the ionization filament temperature and filament material as well as on the chemical state of the sample are investigated. Using rhenium filaments and AgBr as a sample, relative standard deviations of 0.08% are obtained for the bromine isotope ratio determination. In different chemicals the trace content of bromide has been determined to be within the range of 1.3 ppb to 136 ppm with relative standard deviations of 1–15%. For the bromide separation a chromatographic column with an anion-exchange resin or a precipitation of Br− as AgBr is used.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 306 (1981), S. 173-177 
    ISSN: 1618-2650
    Keywords: Spurenbest. von Blei, Thallium in biolog. Material ; Massenspektrometrie ; Isotopenverdünnungsanalyse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein Verfahren zur Bleibestimmung im ppm-Bereich bzw. zur Thalliumbestimmung im ppb-Bereich in biologischen Proben durch massenspektrometrische Isotopenverdünnungsanalyse wird beschrieben. In einer geschlossenen Glasapparatur wird ein Naßaufschluß mit einer HNO3/H2O2-Mischung durchgeführt. Blei wird über einen Anionenaustauscher, Thallium durch elektrolytische Abscheidung abgetrennt. Die Isotopenverhältnismessung erfolgt mit der Silicageltechnik in einem Thermionen-Massenspektrometer. In verschiedenen Pflanzenmaterialien werden Bleigehalte im Bereich von 20–70 ppm mit relativen Standardabweichungen von 0,6–4,5%, in Pflanzenmaterialien und einer Milchpulverprobe Thalliumgehalte im Bereich von 8–250 ppb mit relativen Standardabweichungen von 4,7–16% analysiert.
    Notes: Summary An analytical procedure for the determination of lead in the ppm range and for that of thallium in the ppb range in biological samples by mass spectrometric isotope dilution analysis is described. The decomposition of the samples is carried out in a closed glass apparatus by a mixture of HNO3 and H2O2. Lead is separated by ion-exchange chromatography with a strongly basic anion-exchanger resin, thallium by electrolytic deposition. The isotope ratios are measured by thermal ionization mass spectrometry using the silicagel technique. In samples of different plants the lead content has been determined to be within the range from 20–70 ppm with relative standard deviations of 0.6–4.5%, in plant samples and one milk powder sample the thallium content to be within the range from 8–250 ppb with relative standard deviations of 4.7–16%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 315 (1983), S. 213-216 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Verfahren der massenspektrometrischen Isotopenverdünnungsanalyse sowie eine Messung mit ionenselektiver Elektrode nach chromatographischer Abtrennung zur Bromid-Spurenbestimmung in geologischen Proben beschrieben. Während für erstgenannte Methode ein saurer Aufschluß mit HF Verwendung findet, wird beim zweiten Verfahren ein alkalischer Schmelzaufschluß mit einer Na2CO3/ZnO-Mischung benutzt. Für die Isotopenverhältnismessung79Br/81Br werden negative Thermionen im Massenspektrometer erzeugt. Anhand der Analyse einiger geochemischer Standards des „Centre de Recherches Pétrographiques et Géochimiques“ ergibt sich eine sehr gute Übereinstimmung beider Verfahren im unteren ppm-Bereich. Dabei ist die Isotopenverdünnungstechnik besonders als Eichmethode geeignet.
    Notes: Summary Methods for the determination of bromide traces in geological samples with isotope dilution mass spectrometry and with an ion-selective electrode after chromatographic separation are described. For the mass spectrometric method, an acidic decomposition of the sample with HF is carried out, for the electrochemical analysis the sample is melted in a mixture of Na2CO3/ZnO. The isotope ratio79Br/81Br is determined by producing negative thermal ions in the mass spectrometer. Analyses of some geochemical standards from the “Centre de Recherches Pétrographiques et Géochimiques” show very good agreement in the lower ppm range with both methods. The isotope dilution technique is especially suitable as a calibration method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 317 (1984), S. 622-622 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 310 (1982), S. 146-153 
    ISSN: 1618-2650
    Keywords: Best. von Lanthan, Cer, Neodym in Anorg. Material, Glas, Praseodymoxid, Aluminium ; Massenspektrometrie/Isotopenverdünnungstechnik ; Thermionisation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Spurenbestimmung von La, Ce und Nd durch massenspektrometrische Isotopenverdünnungsanalyse in Laborglas, Praseodymoxid und Aluminiumfolien, welche nach Dotierung mit einem Lanthanoidisotop im Kernreaktor bestrahlt wurden, wird beschrieben. Die gemeinsame Abtrennung der zu analysierenden Lanthanoide aus der Glas- und Aluminiummatrix bzw. ihre Anreicherung gegenüber Praseodym erfolgt über Anionenaustauschchromatographie. Die Ionisation der Proben im Massenspektrometer wird mit Hilfe der Zweiband-Thermionisationstechnik durchgeführt, wobei die Abhängigkeit des Atomionen/ Oxidionen-Verhältnisses von den Ionenquellenbedingungen ermittelt wird. Es können La, Ce und Nd-Gehalte im untersten μg/g-Bereich mit relativen Standardabweichungen zwischen 1–14% bestimmt werden. In den im Kernreaktor bestrahlten Aluminiumproben kann u.a. das 140Ce-Isotop neben einer über 400fach größeren Menge an 139La ermittelt werden. Wesentlicher Vorteil der massenspektrometrischen Isotopenverdünnungsanalyse ist, daß die erhaltenen Ergebnisse relativ richtig sein sollten und auch Isotope bestimmt werden können.
    Notes: Summary The trace determination of La, Ce and Nd by mass spectrometric isotope dilution analysis in laboratory glass, in praseodymium oxide and in aluminium foils which were irridiated in a nuclear reactor after adding a lanthanide isotope is described. The separation of the lanthanides to be analysed from the glass and the aluminium matrix as well as the enrichment from the praseodymium matrix was achieved by anionic exchange chromatography. Ionization of the samples in the mass spectrometer was carried out by double filament thermal ionization technique. The dependence of the atomic ions and lanthanide oxide ions on the ion source conditions was determined. La, Ce and Nd contents in the lower μg/g range could be determined with relative standard deviations of 1–14%. In one of the aluminium foils, the isotope 140Ce e.g. could be analysed in presence of a more than 400 times higher 139La amount. The essential advantage of mass spectrometric isotope dilution analysis is the accuracy of the results and the possibility to analyse isotopes as well as element contents.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Bei Erzeugung negativer Thermionen im Massenspektrometer wird eine Meßtechnik zur genauen Isotopenverhältnisbestimmung 129I/127I entwickelt. Die Anwendung der Isotopenverdünnungsanalyse unter Verwendung eines Indicators, der an dem langlebigen radioaktiven 129I-Isotop angereichert ist, ermöglicht in diesem Zusammenhang auch eine vergleichsweise richtige Iodspurenbestimmung mit dem Massenspektrometer. In verschiedenen, handelsüblichen Speisesalzen sowie in zwei Reinchemikalien werden Iodspuren mit der massenspektrometrischen Isotopenverdünnungsanalyse bestimmt, wobei relative Standardabweichungen von etwa 1,5 % im unteren ppm-Bereich erreicht werden. Die Nachweisgrenze des beschriebenen Verfahrens, welches die Summe aller anorganischen Iodspecies erfaßt, liegt bei 6 ppb. Die zum analytischen Vergleich durchgeführten Bestimmungen mit einer iodidselektiven Elektrode zeigen gute Übereinstimmung der Ergebnisse. Die chemische Abtrennung des Iodidions geschieht mit der Anionenaustausch-Chromatographie.
    Notes: Summary A technique for a precise isotope ratio measurement of 129I/127I is developed in the mass spectrometer by negative thermal ionization. The application of the isotope dilution technique using a spike which is enriched in the longlived radioactive 129I isotope opens the possibility for an accurate iodine trace analysis by mass spectrometry. Different commercially available table salts as well as two pure chemicals are determined for iodine traces by mass spectrometric isotope dilution analysis. Relative standard deviations of about 1.5 % are obtained in the lower ppmrange. The detection limit of this method which analyses the sum of all inorganic species is 6 ppb. For an analytical comparison the same samples are analysed using an iodideselective electrode. The results agree well with the mass spectrometric values. The chemical separation of the iodide ion is carried out by anion-exchange chromatography.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 315 (1983), S. 454-458 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein neu entwickeltes Verfahren, welches eine massenspektrometrische Isotopenverdünnungsanalyse von Nitratspuren ermöglicht, wird beschrieben. Dabei wird die Bildung negativer NO 2 − -Thermionen an einer heißen Metallbandoberfläche zur Analyse benutzt. Die optimalen Ionisationsbedingungen bezüglich Bandmaterial, Bandtemperatur und Probensubstanz werden diskutiert. Angereichertes 15NO 3 − dient als Indicatorlösung. Das Verfahren ermöglicht Nitrat-Spurenbestimmungen in Wasserproben bis in den unteren ng/g-Bereich hinein. Die relative externe Standardabweichung in dem für Trinkwasserproben besonders interessierenden Bereich von 10–30 μg/g beträgt 0,1%. Als definitive Methode ohne eine externe Standardisierung eignet sich das Verfahren besonders als Eichmethode.
    Notes: Summary The development of a new method for the mass spectrometric isotope dilution analysis of nitrate traces is described. The formation of negative NO 2 − thermal ions at a hot metal surface is used for the mass spectrometric detection. The optimum conditions for the ionization process depending on the filament material, the filament temperature and the sample compound are discussed. Enriched 15NO 3 − is used as a spike solution. By this method the nitrate traces could be analysed down to the ng/g-level. In the concentration range 10–30 μg/g which is especially important for drinking water, the relative external standard deviation of the analyses is 0.1%. As the described isotope dilution technique is a definitive method without any external standardization it is especially suitable as a calibration method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 317 (1984), S. 366-366 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 92 (1980), S. 406-407 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...