ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (4)
  • 1982  (4)
  • 1
  • 2
    Publication Date: 1982-01-01
    Print ISSN: 0016-1152
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 310 (1982), S. 146-153 
    ISSN: 1618-2650
    Keywords: Best. von Lanthan, Cer, Neodym in Anorg. Material, Glas, Praseodymoxid, Aluminium ; Massenspektrometrie/Isotopenverdünnungstechnik ; Thermionisation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Spurenbestimmung von La, Ce und Nd durch massenspektrometrische Isotopenverdünnungsanalyse in Laborglas, Praseodymoxid und Aluminiumfolien, welche nach Dotierung mit einem Lanthanoidisotop im Kernreaktor bestrahlt wurden, wird beschrieben. Die gemeinsame Abtrennung der zu analysierenden Lanthanoide aus der Glas- und Aluminiummatrix bzw. ihre Anreicherung gegenüber Praseodym erfolgt über Anionenaustauschchromatographie. Die Ionisation der Proben im Massenspektrometer wird mit Hilfe der Zweiband-Thermionisationstechnik durchgeführt, wobei die Abhängigkeit des Atomionen/ Oxidionen-Verhältnisses von den Ionenquellenbedingungen ermittelt wird. Es können La, Ce und Nd-Gehalte im untersten μg/g-Bereich mit relativen Standardabweichungen zwischen 1–14% bestimmt werden. In den im Kernreaktor bestrahlten Aluminiumproben kann u.a. das 140Ce-Isotop neben einer über 400fach größeren Menge an 139La ermittelt werden. Wesentlicher Vorteil der massenspektrometrischen Isotopenverdünnungsanalyse ist, daß die erhaltenen Ergebnisse relativ richtig sein sollten und auch Isotope bestimmt werden können.
    Notes: Summary The trace determination of La, Ce and Nd by mass spectrometric isotope dilution analysis in laboratory glass, in praseodymium oxide and in aluminium foils which were irridiated in a nuclear reactor after adding a lanthanide isotope is described. The separation of the lanthanides to be analysed from the glass and the aluminium matrix as well as the enrichment from the praseodymium matrix was achieved by anionic exchange chromatography. Ionization of the samples in the mass spectrometer was carried out by double filament thermal ionization technique. The dependence of the atomic ions and lanthanide oxide ions on the ion source conditions was determined. La, Ce and Nd contents in the lower μg/g range could be determined with relative standard deviations of 1–14%. In one of the aluminium foils, the isotope 140Ce e.g. could be analysed in presence of a more than 400 times higher 139La amount. The essential advantage of mass spectrometric isotope dilution analysis is the accuracy of the results and the possibility to analyse isotopes as well as element contents.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Bei Erzeugung negativer Thermionen im Massenspektrometer wird eine Meßtechnik zur genauen Isotopenverhältnisbestimmung 129I/127I entwickelt. Die Anwendung der Isotopenverdünnungsanalyse unter Verwendung eines Indicators, der an dem langlebigen radioaktiven 129I-Isotop angereichert ist, ermöglicht in diesem Zusammenhang auch eine vergleichsweise richtige Iodspurenbestimmung mit dem Massenspektrometer. In verschiedenen, handelsüblichen Speisesalzen sowie in zwei Reinchemikalien werden Iodspuren mit der massenspektrometrischen Isotopenverdünnungsanalyse bestimmt, wobei relative Standardabweichungen von etwa 1,5 % im unteren ppm-Bereich erreicht werden. Die Nachweisgrenze des beschriebenen Verfahrens, welches die Summe aller anorganischen Iodspecies erfaßt, liegt bei 6 ppb. Die zum analytischen Vergleich durchgeführten Bestimmungen mit einer iodidselektiven Elektrode zeigen gute Übereinstimmung der Ergebnisse. Die chemische Abtrennung des Iodidions geschieht mit der Anionenaustausch-Chromatographie.
    Notes: Summary A technique for a precise isotope ratio measurement of 129I/127I is developed in the mass spectrometer by negative thermal ionization. The application of the isotope dilution technique using a spike which is enriched in the longlived radioactive 129I isotope opens the possibility for an accurate iodine trace analysis by mass spectrometry. Different commercially available table salts as well as two pure chemicals are determined for iodine traces by mass spectrometric isotope dilution analysis. Relative standard deviations of about 1.5 % are obtained in the lower ppmrange. The detection limit of this method which analyses the sum of all inorganic species is 6 ppb. For an analytical comparison the same samples are analysed using an iodideselective electrode. The results agree well with the mass spectrometric values. The chemical separation of the iodide ion is carried out by anion-exchange chromatography.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...