Skip to main content
Log in

Iodspurenbestimmung mit der negativen Thermionen-Massenspektrometrie: Analyse von Speisesalzen sowie Vergleich mit Ergebnissen einer ionenselektiven Elektrode

Iodine trace determination by negative thermal ionization mass spectrometry: Analysis of table salts and comparison with results by an ion-selective electrode

  • Originalabhandlungen
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

A technique for a precise isotope ratio measurement of 129I/127I is developed in the mass spectrometer by negative thermal ionization. The application of the isotope dilution technique using a spike which is enriched in the longlived radioactive 129I isotope opens the possibility for an accurate iodine trace analysis by mass spectrometry. Different commercially available table salts as well as two pure chemicals are determined for iodine traces by mass spectrometric isotope dilution analysis. Relative standard deviations of about 1.5 % are obtained in the lower ppmrange. The detection limit of this method which analyses the sum of all inorganic species is 6 ppb. For an analytical comparison the same samples are analysed using an iodideselective electrode. The results agree well with the mass spectrometric values. The chemical separation of the iodide ion is carried out by anion-exchange chromatography.

Zusammenfassung

Bei Erzeugung negativer Thermionen im Massenspektrometer wird eine Meßtechnik zur genauen Isotopenverhältnisbestimmung 129I/127I entwickelt. Die Anwendung der Isotopenverdünnungsanalyse unter Verwendung eines Indicators, der an dem langlebigen radioaktiven 129I-Isotop angereichert ist, ermöglicht in diesem Zusammenhang auch eine vergleichsweise richtige Iodspurenbestimmung mit dem Massenspektrometer. In verschiedenen, handelsüblichen Speisesalzen sowie in zwei Reinchemikalien werden Iodspuren mit der massenspektrometrischen Isotopenverdünnungsanalyse bestimmt, wobei relative Standardabweichungen von etwa 1,5 % im unteren ppm-Bereich erreicht werden. Die Nachweisgrenze des beschriebenen Verfahrens, welches die Summe aller anorganischen Iodspecies erfaßt, liegt bei 6 ppb. Die zum analytischen Vergleich durchgeführten Bestimmungen mit einer iodidselektiven Elektrode zeigen gute Übereinstimmung der Ergebnisse. Die chemische Abtrennung des Iodidions geschieht mit der Anionenaustausch-Chromatographie.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Literatur

  1. International Atomic Energy Agency (IAEA), Intercomparison Run V-8 and V-9. Wien 1980, 1981

  2. Community Bureau of Reference (BCR), Commission of the European Communities, Project 222. Brüssel, 1981

  3. Heckmann MM (1979) J Assoc Off Anal Chem 62:1045

    Google Scholar 

  4. IAEA, Information Sheet Reference Material for the Determination of Total Iodine in Wheat Flour, Code No V-5. Wien 1977

  5. Crecelius EA (1975) Anal Chem 47:2034

    Google Scholar 

  6. Heumann KG (1980) Toxicol Environ Chem Rev 3:11

    Google Scholar 

  7. Heumann KG, Kubassek E, Schwabenbauer W (1977) Fresenius Z Anal Chem 287:121

    Google Scholar 

  8. Heumann KG, Beer F, Kifmann R (1980) Talanta 27:567

    Google Scholar 

  9. Heumann KG, Schindlmeier W (1981) Fresenius Z Anal Chem 306:245

    Google Scholar 

  10. Kaminsky M (1965) Atomic and ionic impact phenomena on metal surfaces, Springer, Berlin, S 165

    Google Scholar 

  11. Persky A, Greene EF, Kuppermann A (1968) J Chem Phys 49:2347

    Google Scholar 

  12. Weast RC (Editor) (1978/79) Handbook of chemistry and physics, 59. Aufl. The Chem Rubber Company, Cleveland

    Google Scholar 

  13. Hilpert K (1968) Diplomarbeit. Mainz

  14. Blais JC, Bolbach G, Brunot A, Cottin M (1976) Int J Mass Spectrom Ion Phys 22:71

    Google Scholar 

  15. Delmore JE (1982) Int J Mass Spectrom Ion Phys (im Druck)

  16. Heumann KG, Hoffmann R (1978) Adv Mass Spectrom 7:610

    Google Scholar 

  17. Heumann KG, Kastenmayer P, Zeininger H (1981) Fresenius Z Anal Chem 306:173

    Google Scholar 

  18. Wedepohl KH (Editor) (1974) Handbook of geochemistry, Bd II-4. Springer, Berlin Heidelberg New York

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Herrn Prof. Dr. H. Kelker zum 60. Geburtstag gewidmet

Der Deutschen Forschungsgemeinschaft sowie dem Fonds der Chemischen Industrie danken wir für die finanzielle Unterstützung.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Heumann, K.G., Schindlmeier, W. Iodspurenbestimmung mit der negativen Thermionen-Massenspektrometrie: Analyse von Speisesalzen sowie Vergleich mit Ergebnissen einer ionenselektiven Elektrode. Z. Anal. Chem. 312, 595–599 (1982). https://doi.org/10.1007/BF00492059

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00492059

Navigation