ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 229-233 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Fused-silica capillary ; Wide bore glass capillary ; Packed column ; Plasma amino acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A procedure is described in which a wide bore glass capillary column is used as an alternative to the more traditional packed column in the analysis of amino acid levels in plasma. The coefficients of variation for all amino acids (with the exception of aspartic acid) were better than 11% with recoveries ranging from 81% to 122%. The data are compared with the corresponding results obtained using a packed column and show significant differences (p 〈 0.005) between values for glycine, serine, isoleucine, proline, methionine, aspartic acid, phenylalanine, and lysine. A similar comparison between results from the wide bore and the fused-silica open tubular (FSOT) column shows better agreement. Adjustment of chromatographic conditions for the wide bore analysis yields results in good agreement with those from FSOT analysis but which still differe significantly from the backed column data.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 555-560 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Capillary, fused-silica ; Plasma amino acid analysis ; “On-column” injection ; Classical ion exchange ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A capillary chromatographic procedure using a fused silica column is described which can be used to quantitatively determine amino acids in plasma following the pre-chromatographic “clean-up” described in a recent paper [1]. In substituting this procedure for that involving a packed column, advantage has been taken of the greater resolving power to separate amino acids from background component peaks. In order to extend this advantage and provide a sound basis for quantitative analysis, the technique of cold on-column injection was employed. As a result, good precision of standard analysis was obtained with relative standard deviation (RSD) values for all amino acids of less than 4%. Application of the entire procedure to plasma samples yields RSD values of better than 10% for all amino acids with recoveries ranging from 72% to 104%. Simultaneous determination of plasma amino acid levels by gas chromatography (GC) using capillary columns and by classical ion exchange (CIE) showed reasonable agreement. Statistical evaluation showed no significant difference between twelve amino acids. Values for the remaining two, namely, phenylalanine and histidine are significantly different (p 〈 0.005). Comparison of the values obtained from GC capillary and packed columns reveals no significant difference between fourteen amino acids. Significant differences exist between results for phenylalanine and tyrosine (p 〈 0.001). It is concluded that there is good agreement between data obtained by GC capillary and CIE techniques and that differences between results for phenylalanine and histidine are method related.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 383-387 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Wide bore glass capillary ; Fused-silica capillary ; Component discrimination ; Butt connectors ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A procedure is described in which a wide bore capillary column is used as an alternative to the more traditional packed column for the quantitative analysis of amino acids as their N-heptafluorobutyryl isobutyl ester (HBB) derivatives. The column, installed in a gas chromatograph previously configured for use with a packed column, is shown to give good reproducibility by repeated determination of amino acid response factors (RSD values for all amino acids are below 3%). A number of problems, encountered during the use of this column, are discussed and suitable techniques to overcome them are reported.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 218-223 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Capillary, glass ; Column preparation ; “Split” vs. “on-column” injection ; Amino acid analysis, quantitative 10 ng level ; Average relative standard deviation 1% ; Fish muscle protein analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A carefully Standardized technique is described for the preparation of glass capillary columns which can be used successfully for routine quantitative amino acid analysis. Comparison is made between two different modes of sample injection. Preliminary quantitative results from “split” injection and “on-column” injection techniques are evaluated statistically and it is concluded that the “on-column” system is a prerequisite for quantitative amino acid analysis by glass capillary gas chromatography. An analysis of fish muscle protein hydrolyzate illustrates an application of this technique and results are compared with those from a packed column analysis.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 234-238 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Packed column ; Wide bore column ; Fused silica column ; Amino acids ; Cerebrospinal fluid (CSF) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: In the present study, the use of gas chromatography (GC) for the determination of amino acids in human cerebrospinal fluid (CSF) is described. Although some amino acids may be determined using a packed column following the removal of glucose, the major interfering component, the inadequate resolution of other amino acids from remaining unidentified components results in poor quantitation. The use of wide bore columns improves reproducibility considerably, but still it does not provide sufficient resolution to enable quantitative determination of all amino acids in human CSF. Good reproducibility data, with CV values for all amino acids of 7% or less and recoveries generally between 80% and 100%, can only be obtained using the fused silica open tubular (FSOT) column. Normal amino acid levels are presented for 10 samples of human CSF, which compare well with data previously reported in the literature.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...