ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 234-238 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed column ; Wide bore column ; Fused silica column ; Amino acids ; Cerebrospinal fluid (CSF) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In the present study, the use of gas chromatography (GC) for the determination of amino acids in human cerebrospinal fluid (CSF) is described. Although some amino acids may be determined using a packed column following the removal of glucose, the major interfering component, the inadequate resolution of other amino acids from remaining unidentified components results in poor quantitation. The use of wide bore columns improves reproducibility considerably, but still it does not provide sufficient resolution to enable quantitative determination of all amino acids in human CSF. Good reproducibility data, with CV values for all amino acids of 7% or less and recoveries generally between 80% and 100%, can only be obtained using the fused silica open tubular (FSOT) column. Normal amino acid levels are presented for 10 samples of human CSF, which compare well with data previously reported in the literature.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 437-441 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica column ; Amino acids ; Urine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This report describes a convenient means of reducing the complex matrix which is responsible for interference during gas chromatographic determination of amino acids in urine. The pre-chromatographic clean-up employs the principle of solid phase extraction using bonded silica incorporating cation exchange groups. This approach avoids the detrimental effects on amino acid recoveries associated with resin-based cation exchangers. In spite of significant reduction in the complexity of chromatograms, only the high efficiency and resolving power offered by the analytical capillary column (e. g. fused silica open tubular, FSOT) is sufficient for quantitative and analysis of amino acids in urine. Reproducibility data from the complete procedure are determined, coefficients of variation (CV) for most amino acids being better than 5% with a mean recovery of 96%.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...