ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pharmaceutical research 14 (1997), S. 810-814 
    ISSN: 1573-904X
    Keywords: formoterol ; radiation treatment ; ESR spectroscopy ; dosimetry ; storage ; HPLC ; degradation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Purpose. Radiation sterilization is becoming increasingly popular for the sterilization of many pharmaceutical products. We have investigated the gamma radiation induced effects on formoterol fumarate by HPLC and ESR spectroscopy. Results and Discussion. Numerical simulation of the evolution of the ESR signal versus dose was performed using linear regression, quadratic fit and power function. The shape of the dosimetric curve is linear in the range 5−30 kGy. Owing to the weak number of free radicals generated during the irradiation, the accuracy of measurements is low. For a dose of 25 kGy, discriminating irradiated from unirradiated samples is possible if the storage period is less than 250 days. The comparison between chromatographic profiles of irradiated and unirradiated samples showed minor differences. Conclusions. From our preliminary results, radiosterilization of formoterol fumarate may be technically feasible. Estimation of the irradiation dose by ESR may be possible but, due to the weak number of free radicals generated during the irradiation, the accuracy of measurements appeared low.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Pharmaceutical research 14 (1997), S. 1186-1191 
    ISSN: 1573-904X
    Keywords: radiosterilization ; ascorbic acid ; ESR ; dosimetry ; decay of radicals
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Purpose. As an alternative to heat and gas exposure sterilization, ionizing radiation is gaining interest as a sterilization process for medicinal products. The aim of this work was to develop equations to describe the ESR curves versus dose and storage time after gamma irradiation of ascorbic acid. Several ESR data sets previously acquired in this laboratory were adopted to check the performance of the models. Results. Limit of detection and limit of discrimination are respectively 0.5 kGy and 2 kGy for ascorbic acid. Linear regression is applicable for doses lower than 25 kGy. Since the radiation dose selected must always be based upon the bioburden of the products and the Degree of Sterility required (ANSI/AAMI/ISO 11137), doses in the range 5−25 kGy could be investigated and linear regression would appear to be the least expensive route to follow and gives good results. Quadratic fit, power function, exponential function and bi-exponential functions are of more general applicability to predict irradiation dose. Decay kinetics for radicals versus storage were considered. Nonhomogeneous kinetics with time-dependent rate (diffusion-controlled second-order reaction) and bi-exponential function appeared valid to reproduce the experimental data. Discrimination between irradiated and unirradiated ascorbic acid is possible after a storage of 800 days. Conclusions. It is worth noting that, at present, ESR is the only technique which proves to be suitable for identification and quantification purposes in irradiated pharmaceuticals. Moreover, other features such as sensitivity, precision, ease and non-destructive readout make ESR superior to other proposed analytical techniques.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Pharmaceutical research 14 (1997), S. 1192-1196 
    ISSN: 1573-904X
    Keywords: dopamine ; norepinephrine ; radiation treatment ; ESR spectroscopy ; dosimetry ; storage
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Purpose. Radiation sterilization is becoming increasingly popular for the sterilization of many pharmaceutical products. We have investigated the gamma radiation induced effects on dopamine and norepineprine by ESR spectroscopy. Results and Discussion. Equations to describe the evolution of the ESR curves versus doses and time of storage are presented. Linear regression is, for dopamine hydrochloride, applicable for doses ranging from 10 to 25 kGy. Since the radiation dose selected must always be based upon the bioburden of the products and the degree of sterility required, doses in the range 10−25 kGy could be investigated and linear regression would appear to be the least expensive route to follow and gives good results. The comportment of noradrenaline bitartrate is more complex and the use of linear regression would appear more hazardous especially for low doses. For doses higher than 25 kGy, a more general equation is required. Power function using only 2 parameters could give good results but must be validated. Decay kinetics for radicals versus storage were considered. Non-homogenous kinetics with time dependent rate constant and bi-exponential function appeared valid to reproduce the decay of radicals for, respectively, dopamine and norepinephrine. Conclusions. It is worth noting that, at present, ESR is the only technique which proved to be suitable for identification and quantification purposes in irradiated pharmaceuticals. Moreover, other features such as sensitivity, precision, ease and non-destructive readout make ESR superior to other proposed analytical techniques.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 14 (1968), S. 483-490 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Local and average heat transfer coefficients have been measured for a sphere in a randomly packed bed. A steady state technique was employed in which internally heated spheres were placed in a bed 35 in. deep and 12 in. sq. Air passed through the bed in downflow, the range of Reynolds numbers being from 120 to 1,700 based on the sphere diameter and the superficial velocity.Average heat transfer coefficients have been measured at twenty-five positions permitting the assessment of the effect of position. An entrance region limited to the first two particle layers in the bed has been verified.Distributions of the local heat transfer coefficient on the surface of a single sphere in the top layer and in the nineteenth layer of the bed have also been measured. These distributions indicate that a laminar boundary layer exists over portions of the sphere surface.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 5 (1991), S. 299-302 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The molecular weights of the recombinant proteins interleukin 2 and interferon gamma were determined by electrospray ionization (ESI) mass spectroscopy on the whole molecules. For interleukin 2 an average experimental mass of 15 549.4 u, was observed in excellent agreement with the theoretical average mass of 15 547.2 u. The mass observed for interferon gamma (16 908.4 u) agreed with the theoretical molecular weight of the monomeric species (16 907.3 u). By ESI mass spectrometry it was possible to determine the presence of proteins lacking one or two amino acids.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Plant/Operations Progress 3 (1984), S. 63-66 
    ISSN: 0278-4513
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 19 (1992), S. 27-32 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Optical multichannel analysis (OMA) was used to follow the kinetics of colour changes in electrochromic polyaniline films when the latter are polarized in an electrolytic medium at different potentials. These colour changes, which are related to the transition from one polymer form to another, are very fast. OMA also allowed us to obtain an apparent value of the film absorption coefficient. In the investigated range (300-800 nm), several absorption phenomena can be displayed which are characteristic of the different polymer forms. Two electrolytic media (1 M HCl and 1 M H2SO4) were compared to investigate the role played by the size of the inserted counter-ion. The overall results allow us to estimate the practical possibility of using polyaniline in electrochromic devices.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 5 (1976), S. 175-177 
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The cheapness of modern minicomputers coupled with the need for rapid and accurate output of X-ray fluorescence analytical data makes the use of computers almost obligatory. The minicomputer has the advantages of immediate availability of results over other methods. In laboratories with an annual output of less than 10 000 determinations the on-line card -punch or magnetic-tape reader coupled through a terminal to a central computer is equally effective though slower.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0018-019X
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The 1α, 25, 26-trihydroxy metabolite of vitamin D3, isolated from bovine serum, was shown to possess the (25 S)-configuration by HPLC. comparison of the 1, 3, 26-triacetate derivative with authentic (25 R)- and (25 S)-samples. The convergent synthesis of (25 R)-1α, 25, 26- and (25 S)-1α, 25, 26-trihydroxycholecalciferols (10a) and (10b) has been accomplished.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 25 (1986), S. 1087-1093 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Solvent accessible peptide bonds in proteins exhibit a 1-3° compression of the OCN bond angle and a corresponding expansion of the NCCa bond angle, relative to buried peptide bonds. These changes are consistent with an increase in hydrogen bonding to the carbonyl oxygen accompanying solvent exposure (J. D. Dunitz and F. K. Winkler, (1975) Acta Cryst. B31, 251-263). For amphiphilic structures such as α-helices, systematic differences in peptide-bond geometry between solvent-exposed and buried residues will generate significant curvature. A decrease of 4° in the OCN bond angle between hydrophilic and hydrophobic sides of an amphiphilic helix will lead to smooth bending, with a radius of curvature of about 70 Å. This curvature is in the range observed for α-helices in proteins. Helix curvature is estimated to have only a small effect on the magnitude and direction of the helical dipole moment.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...