ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0630
    Keywords: 68.55 ; 61.70 ; 74.70
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Ultrathin epitaxial films of YBa2Cu3O7−δ on SrTiO3 prepared by Direct Current (DC) sputtering and pulsed laser deposition were imaged by Atomic Force Microscopy (AFM) to follow the different stages of growth of the thin films. Series of films with thicknesses between 1.2 nm and 12 nm (1–10 monolayers of YBa2Cu3O7−δ) were prepared under identical conditions, optimized with respect to electrical and structural properties, to obtain information on the mechanisms responsible for the formation of growth spirals which are commonly observed in films having a thickness of several 10 nm or more. It could be shown that few layers are formed by a layered growth mode where material is attached laterally to 2D islands which are only one c-axis unit cell in height. In a later stage of growth when about 8–10 layers have been formed, the growth process changes to a mode which is mediated by growth spirals. This could be directly monitored in the AFM images where different defect structures like vertically sheared growth fronts and dendrite-like terraces of stacked islands as well as the resulting growth spirals could be identified.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 229-233 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused-silica capillary ; Wide bore glass capillary ; Packed column ; Plasma amino acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A procedure is described in which a wide bore glass capillary column is used as an alternative to the more traditional packed column in the analysis of amino acid levels in plasma. The coefficients of variation for all amino acids (with the exception of aspartic acid) were better than 11% with recoveries ranging from 81% to 122%. The data are compared with the corresponding results obtained using a packed column and show significant differences (p 〈 0.005) between values for glycine, serine, isoleucine, proline, methionine, aspartic acid, phenylalanine, and lysine. A similar comparison between results from the wide bore and the fused-silica open tubular (FSOT) column shows better agreement. Adjustment of chromatographic conditions for the wide bore analysis yields results in good agreement with those from FSOT analysis but which still differe significantly from the backed column data.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 234-238 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed column ; Wide bore column ; Fused silica column ; Amino acids ; Cerebrospinal fluid (CSF) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In the present study, the use of gas chromatography (GC) for the determination of amino acids in human cerebrospinal fluid (CSF) is described. Although some amino acids may be determined using a packed column following the removal of glucose, the major interfering component, the inadequate resolution of other amino acids from remaining unidentified components results in poor quantitation. The use of wide bore columns improves reproducibility considerably, but still it does not provide sufficient resolution to enable quantitative determination of all amino acids in human CSF. Good reproducibility data, with CV values for all amino acids of 7% or less and recoveries generally between 80% and 100%, can only be obtained using the fused silica open tubular (FSOT) column. Normal amino acid levels are presented for 10 samples of human CSF, which compare well with data previously reported in the literature.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...