ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • GEOPHYSICS  (3)
  • Atmospheric ozone  (1)
  • Cell & Developmental Biology  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pure and applied geophysics 118 (1980), S. 847-857 
    ISSN: 1420-9136
    Keywords: Atmospheric ozone ; Filter instrument intercomparison
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract A commercial version of the prototype New Zealand narrowband interference filter instrument has been run at Garmisch-Partenkirchen since autumn 1977. The vicinity of the Dobson stations Hohenpeissenberg and Arosa permitted a check of the filter instrument's utility, reliability and long-term stability in total ozone measurement by (i) station to station-or ‘short-range’ intercomparisons of daily means and (ii) a several days' direct intercomparison at Arosa in spring 1978. The regression analysis with the Hohenpeissenberg data-covering the five month autumn-winter 1977/78 period with highly variable ozone-shows that the filter instrument's direct-sun modeX AD total ozone values were systematically too low by a conversion factor of 0.93. The excellent proportionality between the instruments is indicated by the standard deviation of only 1,3%. The (−7.0±1.3%) bias perfectly agrees with the result reported byBasher [1] for a similar, yet direct, intercomparison. During the direct Arosa intercomparison the filter instrument also tracked down short-time variations in a remarkable, though biased, parallelism with the Dobson instruments, and theX AD daily means fit well into the ‘prognostic’ relationship derived from the preceding autumn-winter ‘short-range’ intercomparison. A creeping deterioration of the characteristics of the 305.5 nm ‘double filter’ then prevented any furtherX AD total ozone intercomparison. No final decision is possible whether this behaviour after a half year's run is typical or just an unusual exception. The otherwise excellent long-term stability is demonstrated by the comparison of theX CD daily means with the HohenpeissenbergX AD data for a 1 1/2 year's period (autumn 1977–spring 1979), resulting in the same bias relationship as for theX AD total ozone measurements.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0362-2525
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: The Harderian gland blood supply of female and male hamsters was studied using light and electron microscopy. A profuse vascularization surrounding secretory acini was observed. Among the blood vessels, the existence of large and irregular sinusoidal capillaries was apparent. These sinusoids appeared in close association to the basal aspect of the secretory cells. Typical, small, fenestrated capillaries were also observed within the connective tissue. The existence of this particular vascularization together with other morphological features of the secretory cell basal pole suggest a possible endocrine function of these orbital glands.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: Between February and December 1979, 30 correlative comparisons were conducted of ozone profiles derived from the satellite sensor SAGE and those derived from balloon-borne ozonesondes launched in Europe. The mean absolute differences between SAGE and the European sondes when ozone mixing ratio is used as the basis of comparison are listed, and ozone comparisons made at four stations in Europe are plotted as ozone mixing ratio versus altitude. The agreement is considered quite reasonable. Also shown is an April 2, 1979 Garmisch comparison where the time and space differences were very small. The agreement is found to be remarkable. For example, the ratio of SAGE to ozonesonde values at 13 out of 17 levels between 12.5 and 28.5 km lies in the range 0.92-1.06.
    Keywords: GEOPHYSICS
    Type: Nature; 300; Nov. 25
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-18
    Description: Balloon-borne particle counter measurements at Laramie, Wyoming (41 deg N) are used to calculate the expected lidar backscatter at 0.694 micron wavelength from July 1979 to February 1982, a period which included at least four detectable perturbations of the stratospheric aerosol layer due to volcanic eruptions. These calculations are compared with lidar measurements conducted at Garmisch-Partenkirchen (47.5 deg N) during the same period. While the agreement is generally good using only the main mode in the particle size distribution (radius about 0.07 micron) during approximately the first 6 months following a major volcanic eruption, a measured secondary mode near 1 micron radius, when included, improves the agreement. Calculations of the expected backscatter at 25-30 km reveal that substantial number of particles diffuse into this high altitude region about 7 months after a major eruption, and these particles should be taken into account when normalizing lidar at these altitudes.
    Keywords: GEOPHYSICS
    Type: Journal of Geophysical Research (ISSN 0148-0227); 88; April 20
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2019-06-27
    Description: Theoretical and numerical analyses are made of planar, cylindrical and spherical-electrode two-field time-of-flight mass spectrometers in order to optimize their operating conditions. A method is introduced which can improve the resolving power of these instruments by a factor of 7.5. Potential barrier gating in time-of-flight mass spectrometers is also analyzed. Experimental studies of a miniature cylindrical-electrode and a hemispherical-electrode time-of-flight mass spectrometer are presented. Their sensitivity and ability to operate at D-region pressures with an open source make them ideal instruments for D-region ion composition measurements. A sounding rocket experiment package carrying a cylindrical electrode time-of-flight mass spectrometer was launched. The data indicate that essentially 100% of the positive electric charge on positive ions is carried by ions with mass-to-charge ratios greater than 500 below an altitude of 92 km. These heavy charge carriers were present at altitudes up to about 100 km.
    Keywords: GEOPHYSICS
    Type: NASA-CR-148504 , PSU-IRL-SCI-444
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...