Abstract
A commercial version of the prototype New Zealand narrowband interference filter instrument has been run at Garmisch-Partenkirchen since autumn 1977. The vicinity of the Dobson stations Hohenpeissenberg and Arosa permitted a check of the filter instrument's utility, reliability and long-term stability in total ozone measurement by (i) station to station-or ‘short-range’ intercomparisons of daily means and (ii) a several days' direct intercomparison at Arosa in spring 1978.
The regression analysis with the Hohenpeissenberg data-covering the five month autumn-winter 1977/78 period with highly variable ozone-shows that the filter instrument's direct-sun modeX AD total ozone values were systematically too low by a conversion factor of 0.93. The excellent proportionality between the instruments is indicated by the standard deviation of only 1,3%. The (−7.0±1.3%) bias perfectly agrees with the result reported byBasher [1] for a similar, yet direct, intercomparison.
During the direct Arosa intercomparison the filter instrument also tracked down short-time variations in a remarkable, though biased, parallelism with the Dobson instruments, and theX AD daily means fit well into the ‘prognostic’ relationship derived from the preceding autumn-winter ‘short-range’ intercomparison.
A creeping deterioration of the characteristics of the 305.5 nm ‘double filter’ then prevented any furtherX AD total ozone intercomparison. No final decision is possible whether this behaviour after a half year's run is typical or just an unusual exception. The otherwise excellent long-term stability is demonstrated by the comparison of theX CD daily means with the HohenpeissenbergX AD data for a 1 1/2 year's period (autumn 1977–spring 1979), resulting in the same bias relationship as for theX AD total ozone measurements.
Similar content being viewed by others
References
Basher, R. E. (1978),Total ozone measurement: Intercomparison of prototype New Zealand filter instrument and Dobson spectrophotometer, Report, Wallops Flight Center, 14 pp.
Basher, R. E. (1977),The effect of bandwidth on filter instrument total ozone accuracy, J. Appl. Meteor.,16, 803–811.
Basher, R. E. andMatthews, W. A. (1979),Problems in the use of interference filters for spectrophotometric determination of total ozone, J. Appl. Meteor.,16, 795–802.
Dobson, G. M. B. (1931),A photoelectric spectrophotometer for measuring the amount of atmospheric ozone, Proc. Phys. Soc., Lond.,43, 324–339.
Dobson, G. M. B. (1957),Observers' Handbook for the ozone spectrophotometer, Ann. IGY,5, 46–89.
Dobson, G. M. B. andNormand, C. W. B. (1962),Determination of the constants etc. used in the calculation of the amount of ozone from spectrophotometer measurements and an analysis of the accuracy of the results, Ann. IGY,16, 161–191.
Dütsch, H. U. Measurement of atmospheric ozone, Annals of the IQSY, Vol. 1, Geophysical Measurements: Techniques, Observational Schedules and Treatment of Data, The M.I.T. Press, 1968, 234–245
Matthews, W. A. (1972),Agreement between Dobson Spectrophotometer and filter ozonometer measurements of total ozone. J. Appl. Meteor.,11, 239–241.
Matthews, W. A., Basher, R. E. andFraser, G. J. (1974),Filter ozone spectrophotometer, Pageoph,112, 931–938.
Taba, H. (1961),Ozone observations and their meteorological applications, WMO Technical Note,36, 48 pp.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Müller, H., Reiter, R. Intercomparison of New Zealand filter ozonometer and Dobson spectrophotometer total ozone measurements. PAGEOPH 118, 847–857 (1980). https://doi.org/10.1007/BF01593036