ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Wiley-Blackwell  (4,434)
  • 1985-1989  (4,081)
  • 1950-1954  (189)
  • 1925-1929  (164)
Collection
Years
Year
  • 1
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method for the quantitative determination of chlorpromazine and five of its major metabolites in a single sample of biological fluid in the ng/ml range has been developed utilizing gas chromatography/mass spectrometry with selected ion recording. The assay is highly specific and quantification is accomplished by an inverse stable isotope dilution technique, using deuterium-labeled variants of the compounds as internal standards. In this way the concentrations of chlorpromazine and five of its major metabolites (the sulfoxide, the N-oxide, the monodemethylated, the didemethylated, and the 7-hydroxylated compounds) can be determined in biological fluids. Levels in humans have been measured both in plasma and in red blood cells and are compared to those found in related in vitro studies.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 26 (1988), S. 1271-1286 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Random copolymers of ethylene with 1-butene, 1-octene, and 1-octadecene have been prepared using a homogeneous vanadium-based catalyst system. Comonomer contents determined by 13C-NMR analysis of polymer solutions are in the range 1-10 mol%. Crystallinities were estimated by means of density measurements, x-ray diffraction, differential scanning calorimetry, laser Raman spectroscopy, and CPMAS 13C-NMR spectroscopy. The results are compared with those obtained for heterogeneous copolymers of ethylene containing 1-4 mol% 1-butene. As the comonomer content is increased, the crystallinity decreases. The dimension perpendicular to the 110 plane in orthorhombic crystallites decreases linearly with crystallinity. This decrease in crystallite size is accompanied by an increase in the size of the orthorhombic unit cell. For copolymers containing large amounts of 1-octene and 1-octadecene, a second crystalline form appears. Differences in estimates of crystallinity are discussed in terms of looser packing in highly branched copolymers and the extent to which the second crystalline form participates in the phase structure.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 25 (1987), S. 2063-2075 
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Divalent organochromium compounds, Cr(Lig)2, often become active catalysts for the polymerization of ethylene when deposited onto an oxide carrier such as silica or aluminophosphate. Hydroxyl groups are thought to react, releasing one ligand and binding the chromium to the surface. The behavior of the catalyst is then governed by the remaining ligand and the type of carrier. In this study two types of ligands were investigated: cyclopentadienyl and its open ring analog dimethylpentadienyl. This small difference in the type of ligand produces a fundamental difference in the polymerization mechanism. For comparison the mixed ligand chromocene, with one open and one closed ligand, was also synthesized and tested for polymerization.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0887-6258
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new method for quantitating adenosine concentration by capillary gas chromatography-mass spectrometry-selected ion monitoring (GC-MS-SIM) has been developed and used as a reference method for evaluating a newly developed radioimmunoassay (RIA) for adenosine. Details of the GC-MS-SIM method are presented, along with the comparative results and uncertainties of both methods. General considerations in the statistical analysis of method comparison data are discussed with particular reference to studies using quantitative mass spectrometry as the standard method; the adenosine methods are used as specific examples in this discussion. Simultaneous estimation of the y-intercept and slope of the least squares regression line relating the results of the two methods using the 95% joint confidence ellipse demonstrated the absence of either constant or proportional error between the two methods. The relatively small uncertainty in the GC-MS-SIM measurements had no significant effect on the linear regression. Random error between the two methods was detected, and was estimated by the coefficient of variation in the RIA data as ten percent of the RIA value.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Selected ion monitoring of vitamin D metabolites has previously been described but there has been only one detailed description of the measurement by gas chromatography/mass spectrometry (GC/MS) of a number of metabolites in a single plasma sample. We describe here a GC/MS method, using stable isotope labelled internal standards, which allows the estimation of vitamins D2 and D3, and their 25-hydroxy, 24,25-dihydroxy and 25,26-dihydroxy metabolites in a single 2 ml sample of plasma, although more is needed for the measurement of 1,25-dihydroxyvitamin D3. Plasma was extracted on Bond Elut C18 cartridges and initial fractionation carried out on Sep-Pak SIL. Straight-phase high-performance liquid chromatography was required for separation of polyhydroxylated metabolites prior to GC/MS using an LKB 2091 mass spectrometer with conventional packed columns. n-Butylboronate esters were formed across vicinal hydroxyls, followed by formation of trimethylsilyl ethers using trimethylsilylimidazole. The [M - 90 - 15]+ ion for each compound was monitored. Deuterated internal standards were not available for all metabolites and it was necessary to use (2H6)D3 and (2H6)25OHD3 as standards for the measurement of D2 and D3, and 25OHD3 and 25OHD2, respectively, and (2H6)24,25(OH)2D3 as a standards for 24,25(OH)2D3 and 25,26(OH)2D2. Although the [M - 90 - 15]+ ion of 24,25(OH)2D and 25,26(OH)2D has the same mass: charge ratio, derivatives of these compounds are completely separated in the GC system used. The intra-assay precision for all these assays is usually less than 5%.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1040-7685
    Keywords: supercrirical fluid chromatography ; mass spectrometry ; capillary column ; inositol ; phosphate ; phytic acid ; silyl derivatives ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary supercritical fluid chromatography with flame ionization detection appears promising for the separation and detection of silylated inositol phosphates. Inositol triphosphate and phytic acid, following ion exchange to their fully protonated forms, were silylated in one step with the addition of 9 and 12 trimethylsilyl groups, respectively. The resulting derivatives are well behaved in open-tubular chromatography columns with methyl-silicone stationary phase when CO2 is used as the mobile phase. Both flow-splitting and directinjection methods were evaluated. The identities of the derivatives were confirmed by supercritical fluid chromatography-mass spectrometry using chemical ionization with both ammonia and isobutane, and using electron ionization - CO2 charge exchange.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 25 (1985), S. 305-310 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Laminar mixing in a single screw extruder between two miscible liquids is considered. Studies are presented which examine the mixing performance in single screw extruders with mixing sections, variable geometry screws, and multi-viscosity mixtures. Model extruders, set up on engine lathes, were used to mix colored silicone rubber which eventually cured in the screw channel. The cured silicone was then removed and sliced to measure the mixing. Results show mixing as a function of both down channel location and total average strain. For the mixing section study, results support the theory of interfacial area reorientation as the key mechanism in mixing section performance. Increasing viscosity ratio for the multi-viscosity study showed a decrease in mixing rate.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 32 (1986), S. 4959-4969 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Structure property relationship of four different diisocyanates is studied in detail. The isocyanates selected are TDI, MDI Crude, HDI, and IPDI. Physical properties such as mechanical, dynamic mechanical, electrical, and thermal are studied. Dynamic mechanical analyses are based on the compound resonance principle. Among all, IPDI-based polymer showed mediocre trend and TDI-based polymer showed best properties.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 35 (1988), S. 1803-1815 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Thermal properties like glass transition temperature (Tg), initial decomposition temperature (idt), integral procedural decomposition temperature (ipdt), and temperature at various % weight loss of a number of polyurethane systems are reported in this paper. Glass transition temperature was determined on TMA, and other thermal properties were determined by thermogravimetry. The experiments were designed to understand various factors such as length of chain extender moiety, flexibility of chain extender units by substitution of ether link in the diol chain, nature of bonds (unsaturation) in the extender unit, and nature of diisocyanates.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...