ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Springer  (23)
  • American Meteorological Society (AMS)
  • 2000-2004  (16)
  • 1955-1959  (7)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Development genes and evolution 210 (2000), S. 270-275 
    ISSN: 1432-041X
    Keywords: Key words Dlx ; Homeobox ; Dentition ; Tooth
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract  The mammalian Dlx homeobox gene family has been shown to play multiple roles in tooth development, but a detailed comparison of the expression pattern of all members throughout tooth development has been lacking. We provide such an analysis for the six known murine Dlx genes. The expression patterns for these genes allow a refinement of previously proposed models for the role of Dlx genes in tooth type specification and raise the possibility of roles for subsets of these genes in tooth initiation, morphogenesis (enamel navel formation, enamel knot induction, cervical loop growth), and enamel formation. The relationship of Dlx gene expression to their genomic organization suggests coordinate regulation of linked genes at early stages but regulatory differences at later stages.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Naturwissenschaften 42 (1955), S. 442-443 
    ISSN: 1432-1904
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 760-769 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Verfasser haben eine semimikro- und eine mikrogravimetrische Methode und ein spektrophotometrisches Verfahren zur Bestimmung von Calcium mit Loretin (7-Jod-8-hydroxychinolin-5-sulfonsäure) ausgearbeitet. Nach Festlegung des Umrechnungsfaktors des Calciumloretinats auf gravimetrischem und thermogravimetrischem Wege wurde gezeigt, daß durch Semimikrogravimetrie Calciummengen von 5 bis 50 mg mit einem mittleren Fehler von 0,35% bestimmbar sind. Die mikrogravimetrische Methode eignet sieh für 0,2 mg Calcium/ml mit einem mittleren Fehler von 0,45%. Der Einfluß einer Reihe von Fremdionen wurde untersucht. Die meisten davon stören nicht, auch wenn sie in bedeutender Menge vorhanden sind. Durch indirekte Spektrophotometrie, nämlich durch Auflösen des Calciumloretinats in überschüssiger Eisen(III)lösung gelang es, Calciummengen in der Größenordnung von 20μg mit einem mittleren Fehler von 0,35% zu bestimmen.
    Abstract: Summary The authors have elaborated a method (semi-micro and micro-gravimetric) and also a spectrophotometric method for determining calcium by means of loretin. After establishing the analytical factor for calcium loretinate by the gravimetric and the thermogravimetric methods, they showed the possibility of determining calcium on the semimicro gravimetric scale for quantities ranging from 5 mg to 50 mg, the mean error being 0.35%. The microgravimetric method allows the minimum quantity to be determined to be reduced to 0.2 mg calcium per ml, the mean error being 0.45%. A study was made of the influence of a number of foreign ions. Most of them do not harm the determination, even though they are present in considerable amounts. By indirect spectrophotometry, notably by dissolving the calcium loretinate in an excess of ferric solution, the writers have succeeded in determining amounts of calcium of the order of 20μg with a mean error of 0.35%.
    Notes: Résumé Les auteurs ont élaboré une méthode semi-micro et micro-gravimétrique et une méthode spectrophotométrique pour le dosage du calcium par la lorétine. Après avoir établi le facteur analytique du lorétinate de calcium par voie gravimétrique et thermogravimétrique, ils ont démontré la possibilité de doser le calcium à l'échelle semi-micro gravimétrique pour des quantités allant de 5 mg à 50 mg, l'erreur moyenne étant de 0,35%. La méthode microgravimétrique permet de ramener la quantité minima à doser à 0,2 mg de calcium par ml, l'erreur moyenne étant de 0,45%. L'influence d'une série d'ions étrangers fut étudiée. La plupart ne gênent pas le dosage, même s'ils sont présents en quantités importantes. Par spectrophotométrie indirecte, notamment en redissolvant le lorétinate de calcium dans un excès d'une solution ferrique, les auteurs ont réussi à doser des quantités de calcium de l'ordre de 20μg avec une erreur moyenne de 0,35%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1572-8382
    Keywords: dialogue systems ; multilingual NL generation ; natural language processing ; public administration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Law
    Notes: Abstract This paper presents two projects concerned with the application of natural language processing technology for improving communication between Public Administration and citizens. The first project, GIST,is concerned with automatic multilingual generation of instructional texts for form-filling. The second project, TAMIC, aims at providing an interface for interactive access to information, centered on natural language processing and supposed to be used by the clerk but with the active participation of the citizen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1572-9672
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Two FUV Spectral imaging instruments, the Spectrographic Imager (SI) and the Geocorona Photometer (GEO) provide IMAGE with simultaneous global maps of the hydrogen (121.8 nm) and oxygen 135.6 nm components of the terrestrial aurora and with observations of the three dimensional distribution of neutral hydrogen in the magnetosphere (121.6 nm). The SI is a novel instrument type, in which spectral separation and imaging functions are independent of each other. In this instrument, two-dimensional images are produced on two detectors, and the images are spectrally filtered by a spectrograph part of the instrument. One of the two detectors images the Doppler-shifted Lyman-α while rejecting the geocoronal `cold’ Ly-α, and another detector images the OI 135.6 nm emission. The spectrograph is an all-reflective Wadsworth configuration in which a grill arrangement is used to block most of the cold, un-Doppler-shifted geocoronal emission at 121.567 nm. The SI calibration established that the upper limit of transmission at cold geocoronal Ly-α is less than 2%. The measured light collecting efficiency was 0.01 and 0.008 cm2 at 121.8 and at 135.6 nm, respectively. This is consistent with the size of the input aperture, the optical transmission, and the photocathode efficiency. The expected sensitivity is 1.8×10−2 and 1.3×10−2 counts per Rayleigh per pixel for each 5 s viewing exposure per satellite revolution (120 s). The measured spatial resolution is better than the 128×128 pixel matrix over the 15°×15° field of view in both wavelength channels. The SI detectors are photon counting devices using the cross delay line principle. In each detector a triple stack microchannel plate (MCP) amplifies the photo-electronic charge which is then deposited on a specially configured anode array. The position of the photon event is measured by digitizing the time delay between the pulses detected at each end of the anode structures. This scheme is intrinsically faster than systems that use charge division and it has a further advantage that it saturates more gradually at high count rates. The geocoronal Ly-α is measured by a three-channel photometer system (GEO) which is a separate instrument. Each photometer has a built in MgF2 lens to restrict the field of view to one degree and a ceramic electron multiplier with a KBr photocathode. One of the tubes is pointing radially outward perpendicular to the axis of satellite rotation. The optic of the other two subtend 60° with the rotation axis. These instruments take data continuously at 3 samples per second and rely on the combination of satellite rotation and orbital motion to scan the hydrogen cloud surrounding the earth. The detective efficiencies (effective quantum efficiency including windows) of the three tubes at Ly-α are between 6 and 10%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1439-0361
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1436-5073
    Keywords: Key words: Aluminium; plasma-assisted nitriding; AlN; AES; TEM.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract.  Detailed examinations were made by AES depth profiling, SEM, TEM and electron diffraction to get information about the relation between treatment conditions and the state of plasma-nitrided aluminium. The chemical composition and the elemental depth distribution were proofed to be depending on gas phase mixture, pressure and temperature during plasma treatment. The admixture of hydrogen during presputtering for surface cleaning and during nitriding results both in an improved nitriding behaviour and in a reduction of the formation of conical-shaped particles at the surface. The microstructure of the nitride layer isn’t depending on tested process conditions significantly. Surface and interface between layer and substrate are roughly in a scale of a few ten nanometers owing to sputtering effects. The main phase inside the layer is nanocrystalline AlN of the known hexagonal modification. In addition, some crystallites of remaining aluminium are present as a second phase. In contrast to nitrogen-implanted aluminium no preferred lattice orientation of the AlN phase was evident.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Atlantic economic journal 28 (2000), S. 164-185 
    ISSN: 1573-9678
    Source: Springer Online Journal Archives 1860-2000
    Topics: Economics
    Notes: Abstract This paper provides a comprehensive, up-to-date picture of the job market for economists using new survey data on job search and employment experiences for a recent cohort of market participants. Several empirical facts are established about the labor market for economists based on separate surveys of job market applicants and chairs of programs advertising job openings in economics. In addition to providing descriptive statistics, this paper examines methods to reduce the costs of job search and recruiting and describes how market outcomes differ by department rank. Such information is of interest to current and future market participants, to advisors of job candidates, and to search committees.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Annals of mathematics and artificial intelligence 28 (2000), S. 39-41 
    ISSN: 1573-7470
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Mathematics
    Notes: Abstract A synthetic view of advancements in the field of natural language processing and intelligent interfaces in the last ten years is provided and some prospects for future research in this field are briefly discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-0878
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Zusammenfassung Umladebereich und mittlerer isoelektrischer Punkt (IEPM) verschiedener menschlicher Gewebe wurden mit Hilfe von gestuften Reihen gepufferter Lösungen vom Fluorochrom Acridinorange auf fluoreszenzmikroskopischem Wege bestimmt. Zum Vergleich wurde an Schnittpräparaten der gleichen Gewebe die Bestimmung von Umladebereich und IEPM mit den Diachromen Methylenblau und Rubin S durchgeführt. Es zeigte sich, daß das Fluorochrom Acridinorange in der Bestimmung des Umladebereiches und IEPM den Diachromen überlegen ist. Infolge der höheren Nachweisempfindlichkeit von Acridinorange und seiner Fluoreszenzmetachromasie läßt sich der Umladebereich viel leichter als bei den Hellfeldfarbstoffen einengen und somit genauer bestimmen. Während man bei Verwendung von Diachromen zur exakten Bestimmung des IEPM zwei Farbstoffe benötigt, genügt bei der Acridinorange Methode ein Farbstoff. Die mit Acridinorange bestimmten Werte vom Umladebereich und IEPM der einzelnen Gewebselemente liegen meist weiter im sauren Bereich als bei Bestimmung mit Diachromen. Bei dem Vergleich unfixierter, in Alkohol oder Formalin gehärteter Gewebe ergab sich, daß nach Fixierung die untere Grenze vom Umladebereich gegenüber der an unfixiertem Gewebe bestimmten weiter in den sauren Bereich verschoben ist.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...