ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Years
  • 1
    Publication Date: 2019-07-20
    Description: For a variety of medical and scientific reasons, human bones can be exposed to ionizing radiation. At relatively high doses (30,0005,000 Gy), ex vivo ionizing radiation is commonly used to sterilize bone allografts. However, ionizing radiation in these applications has been shown to increase risk of fracture clinically and decrease bone quality. Previously, we observed a significant decrease in compressive static strength and fatigue life of ex vivo whole bones exposed to x-ray radiation at 17,000 Gy and above; no changes in compressive mechanical properties were observed for radiation doses of 1,000 Gy and below. The gap in doses between no mechanical change (1,000 Gy) and significant mechanical degradation (17,000 Gy) is large, and it is unclear at what dose mechanical integrity begins to diminish in whole bones, and if its effects differ in response to static versus cyclic mechanical loading. This is a major clinical concern, as trabecular and cortical bone allografts are commonly used in structural, load-bearing applications. To gain insight into the effect of ionizing radiation from 1,000-17,000 Gy, we conducted an ex vivo radiation study on the static and fatigue mechanical properties of the vertebral whole bone. Our objectives were to: (1) quantify the effect of exposure to ex vivo ionizing radiation on the mechanical integrity (compressive static and fatigue) of whole bones; and (2) evaluate, if there are observed differences in mechanics, if they differ in magnitude for static versus cyclic properties. The results of this study will give insight into the need for changes in protocols for bone allograft radiation sterilization procedures.
    Keywords: Life Sciences (General)
    Type: ARC-E-DAA-TN63229 , Orthopaedic Research Society Annual Meeting; Feb 02, 2019 - Feb 05, 2019; Austin, TX; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-30
    Description: Clinical exposure to ionizing radiation could put cancer radiotherapy or bone allograft patients at an increased risk of fracture. In these applications, ionizing radiation levels can range from accumulative 50 Gy for radiotherapy cancer treatment, to acute 35,000 Gy for allograft sterilization. Ionizing radiation has been shown to decrease bon equality through reduced strength and post-yield properties and degrade collagen integrity through either increased crosslinks (advanced glycation end products, AGEs)or fragmentation. It is unclear which collagen structural change accounts for reduced strength. The dose-dependent effect of ionizing radiation on mechanical and biochemical properties of whole bones are not well understood, particularly for ex vivo doses ranging from 50 to 35,000 Gy.
    Keywords: Life Sciences (General)
    Type: ARC-E-DAA-TN54791 , World Congress of Biomechanics; Jul 08, 2018 - Jul 12, 2018; Dublin; Ireland
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-12-12
    Description: One potentially important bone quality characteristic is the response of bone to cyclic (repetitive) mechanical loading. In small animals, such as in rats and mice, cyclic loading experiments are particularly challenging to perform in a precise manner due to the small size of the bones and difficult-to-eliminate machine compliance. Addressing this issue, we developed a precise method for ex vivo cyclic compressive loading of isolated mouse vertebral bodies. The method has three key characteristics: 3D-printed support jigs for machining plano-parallel surfaces of the tiny vertebrae; pivotable loading platens to ensure uniform contact and loading of specimen surfaces; and specimen-specific micro-CT-based finite element analysis to measure stiffness to prescribe force levels that produce the same specified level of strain for all test specimens. To demonstrate utility, we measured fatigue life for three groups (n = 5-6 per group) of L5 vertebrae of C57BL/6J male mice, comparing our new method against two methods commonly used in the literature. We found reduced scatter of the mechanical behavior for this new method compared to the literature methods. In particular, for a controlled level of strain, the standard deviation of the measured fatigue life was up to 5-fold lower for the new method (F-ratio = 4.9; p 〈 0.01). The improved precision for this new method for biomechanical testing of small-animal vertebrae may help elucidate aspects of bone quality.
    Keywords: Life Sciences (General)
    Type: ARC-E-DAA-TN63226 , Bone Reports (e-ISSN 2352-1872); 9; 165-172
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...