Publication Date:
2006-02-14
Description:
The principal objectives of the experiment are to determine zero-g start-up performance for conventional and diode low temperature heat pipes, to evaluate heat pipe performance in zero-g for an extended period of time, to determine zero-g transport capability of each heat pipe, and to determine diode operation, including forward conductance, turndown ratio, and transient behavior. Two heat pipes, a fixed conductance transporter heat pipe and a thermal diode heat pipe, are coupled with a radiant cooler system. Both pipes are charged with ethane. Also integrated with the radiator is a phase change material (PCM) canister which provides temperature stability during transport tests. N-heptane, which has a melting/freezing point of 182 K, is used as the PCM. The high heat capacity (28 W-hr of latent heat) provided by the canister permits high power heat pipe testing at constant temperature.
Keywords:
FLUID MECHANICS AND HEAT TRANSFER
Type:
NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 70-73
Format:
text
Permalink