ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Cell & Developmental Biology  (4)
  • Life and Medical Sciences  (4)
  • Amino acids  (3)
  • Bone  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 15 (1974), S. 189-199 
    ISSN: 1432-0827
    Keywords: Bone ; Densitometry ; X-ray ; Radiation ; Specific gravity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract X-ray and γ-radiation techniques for evaluating bone density under field conditions in cattle and sheep were investigated. The best results were obtained from measurements of the density of radiographs of tibial tarsal bones of sheep and from the absorption of γ-radiation of the tibial tarsal bones of sheep and the fibular tarsal bones of cattle. The γ-radiation techniques may be carried out rapidly under field conditions (up to 30 animals an hour) and bone density can be estimated with a standard error of 0.042–0.046 SG units.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 15 (1974), S. 181-188 
    ISSN: 1432-0827
    Keywords: Biopsy ; Bone ; Calcium ; Phosphorus ; Specific gravity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract The specific gravities (SG) of bone samples taken from various parts of the skeleton of cattle and sheep were determined gravimetrically in an effort to establish which sites give the most reproducible and uniform results, so that between animals, or sequential within animals, comparisons may be made with maximum sensitivity. Samples obtained from the mandible of sheep and the rib of cattle and sheep were found to be too variable to be useful for most purposes. Best results were obtained using whole bones which are easily prepared, such as the tibial tarsal bones of cattle and sheep and the fibular tarsal bone of cattle. These bones gave within animal deviations of 0.012–0.024 SG units, when comparing left bone with right bone. Slightly higher values were obtained for coccygeal vertebrae from cattle and distal metacarpal condyles from sheep. SG was related to ash, calcium and phosphorus contents of coccygeal vertebrae of cattle and it is considered that, for survey work on the mineral status of the bones of cattle and sheep, the correlations are sufficiently high to make their determination unnecessary. This will enable radiation determined SG techniques to be applied to this type of work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Morphology 19 (1908), S. 511-540 
    ISSN: 0362-2525
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Additional Material: 17 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Morphology 28 (1916), S. 135-144 
    ISSN: 0362-2525
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Morphology 23 (1912), S. 31-43 
    ISSN: 0362-2525
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Morphology 27 (1916), S. 401-411 
    ISSN: 0362-2525
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 234-238 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed column ; Wide bore column ; Fused silica column ; Amino acids ; Cerebrospinal fluid (CSF) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In the present study, the use of gas chromatography (GC) for the determination of amino acids in human cerebrospinal fluid (CSF) is described. Although some amino acids may be determined using a packed column following the removal of glucose, the major interfering component, the inadequate resolution of other amino acids from remaining unidentified components results in poor quantitation. The use of wide bore columns improves reproducibility considerably, but still it does not provide sufficient resolution to enable quantitative determination of all amino acids in human CSF. Good reproducibility data, with CV values for all amino acids of 7% or less and recoveries generally between 80% and 100%, can only be obtained using the fused silica open tubular (FSOT) column. Normal amino acid levels are presented for 10 samples of human CSF, which compare well with data previously reported in the literature.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 437-441 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica column ; Amino acids ; Urine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This report describes a convenient means of reducing the complex matrix which is responsible for interference during gas chromatographic determination of amino acids in urine. The pre-chromatographic clean-up employs the principle of solid phase extraction using bonded silica incorporating cation exchange groups. This approach avoids the detrimental effects on amino acid recoveries associated with resin-based cation exchangers. In spite of significant reduction in the complexity of chromatograms, only the high efficiency and resolving power offered by the analytical capillary column (e. g. fused silica open tubular, FSOT) is sufficient for quantitative and analysis of amino acids in urine. Reproducibility data from the complete procedure are determined, coefficients of variation (CV) for most amino acids being better than 5% with a mean recovery of 96%.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 509-516 
    ISSN: 0935-6304
    Keywords: Ion exchange chromatography ; HPLC ; GC ; Quantitation ; Amino acids ; Physiological fluids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Methodologies for quantitative analysis of amino acids in physiological fluids based on classical ion exchange, high performance liquid chromatography, and gas chromatography are analyzed. As judged by the relative number of reports on these techniques, it appears that classical ion exchange continues to be the main method of choice for amino acid determinations and only limited advantage has been taken of the benefits (e.g. lower capital outlay and running costs and shorter analysis times) offered by other techniques. More importantly, however, there appears to be insufficient quantitative evaluation of the methodologies used. As a result, the validity of many reports based on data from amino acid analysis of physiological samples may be questioned.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...