ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • International Union of Crystallography (IUCr)  (5)
  • 1
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The synchrotron X-ray results reported here are from the first high-resolution triple-crystal diffraction experiments performed at the Australian National Beamline Facility (ANBF). At the centre of the ANBF is a multipurpose high-resolution two-axis vacuum X-ray diffractometer. The Si(111) sample studied has been implanted with B+ ions through a one-dimensional SiO2 strip pattern with a 5.83 μm period and 4 μm open region, to produce a sample with a periodic superstructure in the lateral direction. The triple-crystal data were collected in the form of two-dimensional intensity maps in the vicinity of the 111 Bragg peak. Results collected in both air and vacuum are compared, as are results with and without the oxide layer. The data collected in vacuum indicate that it is possible at the ANBF to measure lattice distortions perpendicular to the sample surface with a 50 Å depth resolution.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 3 (1996), S. 289-295 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: A paraboloidally tapered glass monocapillary was used to focus an 8 keV monochromated synchrotron bending-magnet X-ray beam into a 40 (±5) μm focal spot located 45 (±5) mm from the exit of the capillary. This focal spot had a measured intensity gain of 120 (±10) times the intensity present in an equivalent cross section of the unfocused beam from the monochromator. This focused beam was used to obtain oscillation diffraction patterns on image plates from a hen egg-white lysozyme protein crystal in two distinct geometries: one with the specimen crystal at the capillary exit and the other with the crystal at the beam focus. In the first geometry, focused Bragg reflections were observed at the focal plane. In the second geometry, diverging Bragg reflections of high intensity from a small crystal volume were observed. Image-plate diffraction patterns for these two geometries were compared with exposures with equivalent integrated diffracted intensities obtained using a 100 × 100 μm unfocused X-ray beam with the same crystal. The use of the focused beam resulted in a reduction in the exposure time required to produce equivalent patterns by a factor of between 70 and 100.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 5 (1998), S. 107-111 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 5 (1998), S. 823-825 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: An eight-position capillary sample spinning stage has been developed for use in conjunction with the versatile vacuum diffractometer (BIGDIFF) at BL20B at the Photon Factory. BIGDIFF is often used in its powder diffraction mode using powders mounted in capillaries and up to eight imaging plates to record the diffraction pattern from the sample. Using the multiple spinning stage a number of diffraction patterns can be recorded on the imaging plates if the imaging-plate cassette is moved behind the Weissenberg screen to a new position after exposure of the sample to the beam. Not only is this system more efficient in terms of time saved in the pumping-down process, but also it has the advantage of allowing the diffraction patterns of standards to be recorded, thereby calibrating both the angle scale of the diffractometer and the intensity scales of the imaging plates absolutely.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 28 (1995), S. 513-517 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: Australian scientists have built and installed an X-ray powder diffractometer of an unusual design on the Australian beamline at the Photon Factory synchrotron-radiation facility within the National Laboratory for High Energy Physics (KEK), Tsukuba, Japan. The diffractometer is a Debye–Scherrer camera of 0.573 m radius. The place of the cylindrical film in a conventional camera of this type is taken by image plates. To minimize scattering and absorption by air, the instrument can be evacuated. The instrument is now in operation and has been tested with a specimen of the rutile phase of TiO2. This material has been thoroughly studied previously and it has been demonstrated that time-of-flight neutron powder diffraction, conventional neutron powder diffraction, single-crystal neutron diffraction and single-crystal X-ray diffraction lead to a consistent set of values for the anisotropic thermal parameters and the one positional parameter. The powder specimen of rutile for use at KEK was diluted with gum tragacanth and inserted into a glass capillary of 0.5 mm diameter. The beam from the synchrotron is incident on a silicon (111) channel-cut monochromator. Data were collected to ±165°2θ at wavelengths of 0.62, 1.10, 1.54 and 1.90 Å. The exposure time for each data set was 10 min. The resolution of the instrument agrees with theoretical prediction and is such that the full width at half-maximum of a reflection varies from 0.04° at 20°2θ to 0.2° at 160°2θ for a wavelength of 1.54 Å. The intensity from a 10 min exposure is more than sufficient for Rietveld refinement (Rexp 〈 1%).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...