ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • American Institute of Physics (AIP)  (3)
  • American Chemical Society  (2)
Collection
Publisher
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Macromolecules 15 (1982), S. 66-71 
    ISSN: 1520-5835
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 72 (2001), S. 119-127 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Recent development of the JT-60U charge exchange recombination spectroscopy (CXRS) diagnostic system is reported. The measurements of the radial profiles of the ion temperatures, the toroidal and poloidal rotation velocities, and the impurity density are based on CXR spectra of fully stripped carbon ions induced by neutral beam injection. Measurements are made simultaneously at 59 spatial points (23 toroidal and 36 poloidal) with a time resolution of 1/60 s throughout the full discharge pulse of 15 s. Considerable effort has been expended to ensure the automatic provision of reliable profile data, where the mechanical components of the system must cope with both a baked tokamak vessel (∼300 °C) and an expected disruption-induced acceleration of up to 60 g, where g denotes the gravitational acceleration, i.e., 9.8 m2/s. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 351-354 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The divertor impurity monitoring system of the International Thermonuclear Experimental Reactor has been designed. The main functions of this system are to identify impurity species and to measure the two-dimensional distributions of the particle influxes in the divertor plasmas. The wavelength range is 200–1000 nm. The viewing fans are realized by molybdenum mirrors located in the divertor cassette. With additional viewing fans seeing through the gap between the divertor cassettes, the region approximately from the divertor leg to the x point will be observed. The light from the divertor region passes through the quartz windows on the divertor port plug and the cryostat, and goes through the dog-leg optics in the biological shield. Three different type of spectrometers: (i) survey spectrometers for impurity species monitoring, (ii) filter spectrometers for the particle influx measurement with the spatial resolution of 10 mm and the time resolution of 1 ms, and (iii) high dispersion spectrometers for high resolution wavelength measurements are designed. These spectrometers are installed just behind the biological shield (for λ〈450 nm) to prevent the transmission loss in fiber and in the diagnostic room (for λ≥450 nm) from the point of view of accessibility and flexibility. The optics have been optimized by a ray trace analysis. As a result, 10–15 mm spatial resolution will be achieved in all regions of the divertor. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 59 (1988), S. 1515-1517 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: In order to study impurity behavior on the JT-60 plasma, a spectroscopic diagnostic system, which is capable of measuring many spectra of impurity ions and their spatial distributions simultaneously, has been developed. This system consists of interchangeable unit-type spectrographs which have different lines of sight. Four types of grazing incidence spectrographs are prepared as unit-type spectrographs. These spectrographs cover the nominal wavelength regions 0.5–5, 0.5–50, 2.0–50, and 50–122 nm, respectively, and have holographic gratings with flat focal fields. Image-intensified 1024- or 512-channel photodiode arrays are used as detectors for all spectrographs. Four unit-type spectrographs are used for observing the main plasma, and two unit-type spectrographs are used for observing the plasma near the null point of the diverted discharge. One of these spectrographs has been calibrated absolutely in the wavelength region 27.5–120 nm using synchrotron radiation from the Photon Factory (National Laboratory for High Energy Physics).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 1982-01-01
    Print ISSN: 0024-9297
    Electronic ISSN: 1520-5835
    Topics: Chemistry and Pharmacology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...