ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Zone-electrophoretic sample treatment ; Basic and acidic compounds ; Biological samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modified valve arrangement for zone-electrophoretic sample treatment (ZEST)-which is coupled on-line with column liquid chromatography — is used to pretreat biological (plasma) samples. Carry-over of plasma proteins depends on the pH of the electrophoresis buffer. The determination of propranolol, metoprolol, cromolyn and salicylic acid demonstrates that both basic and acidic analytes can be isolated from the plasma matrix with high selectivity. Analogous piperazines, with different protein binding properties, were used to study the influence of protein binding on the recovery. It is shown that high protein can cause a decreased recovery.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Sample treatment ; Zone electrophoresis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The design of a new valve arrangement for zone-electrophoretic sample treatment (ZEST) coupled online with high performance liquid chromatography is described. Characteristics of this valve, such as the internal heat development as a function of the current, have been investigated. By using quinidine and desipramine as model compounds it is shown that charged compounds can be isolated from biological samples, in about 15 min, with high selectivity. The carry-over of proteins to the analytical column has been compared with the carry-over using a pre-column sample clean-up method. The detection limits of quinidine and hydroquinidine (50 ng/ml), using zone-electrophoretic sample treatment coupled with column liquid chromatography, are in the same range as with direct injections using pre-columns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Electrodialytic sample treatment ; On-line coupling
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An electrodialytic sample treatment method coupled on-line with high-performance liquid chromatography (EDIST-HPLC) is discussed in this paper. The performance of EDIST as a function of the donor-phase (sample solution) flow rate, the voltage applied over the electrodialysis block, and the time of dialysis has been studied using the basic drug ephedrine as a model compound. Enrichment of the analyte by a factor of 10–20 was possible. The determination of human plasma spiked with ephedrine is briefly discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Electrodialytic sample treatment ; Computer models ; Analyte enrichment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Basic considerations for analyte enrichment and recovery obtainable by electrodialysis as a sample treatment method are given. Equations are derived which describe the dependence of the concentration profiles of ionic compounds on the electric field strength in a set-up with stagnant donor and acceptor solutions. It is shown that analyte recovery increases when less ion-selective membranes are used in the electrodialysis cell. Computer models are used to estimate the analyte enrichment for a flowing donor (sample) and a stagnant acceptor phase. About 10-fold enrichment can be obtained in an electrodialytic sample treatment system within 20 min under maximum current conditions. A compromise has to be found between analyte recovery and the donor (sample) flow rate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0730-6679
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: One of the basic prerequisites for rational and high quality production of plastic parts is a tool layout tailored to the production process. To date, both design and construction have generally been based on values acquired by experience. This first, necessitates highly qualified personnel and second, involves what is frequently time consuming and costly finishing work. Experience acquired so far with computer-aided layout of injection molds shows that even a designer with little experience reaches the target more quickly and more reliably. At the same time he is able to draw on the results of intricate calculation and simulation methods which he was unable to apply in the past for reasons of time alone. This paper thus sets out the possibilities currently open and the experience available for computer-aided mold layout. The chief point of focus here is a system for the layout of injection molds. Working on from this system, however, the potentials for computer application are presented for blow mold- and foaming mold-design. After finding the mold principle, mold layout essentially divides up into two major areas, namely dimensioning calculations (CAE) and compilation of production documents (CAD). In dimensioning, the different functional elements of the mold are calculated. The aids that have been developed and the potentials of computer-aided dimensioning are presented with examples from the fields of rheological, thermal, and mechanical mold layout. Computer-aided rheological layout divides up into two steps. The first gives information on qualitative filling behavior (filling picture, flow paths) and the second provides quantitative results (pressures, shear stresses, temperatures). Computer-aided thermal layout similarly divides up into part steps. These are a rough overall energy balance, a rough layout of the tempering system, a segmented layout, and a homogeneity check, which involves simulating the temperature conditions in the mold by means of difference methods. When it comes to mechanical layout of the mold, programs are available for deformation calculations on basic cases and these will frequently be sufficient. For more complex cases of loading and deformation, a finite element program is used. Graphic data processing units can be used to supply extra facilities - first, to provide an aid for the simulation programs in dimensioning and second, to rationalize the compilation of the production documents. An illustration of a CAD workplace is given, incorporating the necessary computer configuration and peripherals. Compiling production documents is essentially a problem of variant design. The variants in this case are the individual components of the mold and a number of standardized accessories that can be called up as “standardized components.” The mold cavity, however, always has to be a free design. All programs are dialogue driven and are in a standardized manner so that even designers with no data processing experience can use the computer as an aid. The CAD/CAE system presented duly fulfils all these requirements. It allows the designer, at a single computer work station, to carry out both simulation and dimensioning calculations, to obtain information on material data, and to compile production documents on the basis of variant and free design. This provides the designer with a readily manageable aid and makes a considerable contribution towards improving the design result. Finally, the capacity of different computer concepts and the CAE/CAD/CAM systems on the market are discussed. For the future it will be possible to establish a computer-aided link between the different areas of design, from development of the molded part, via mold design and production, through setting the processing parameters of the injection molding machine.
    Additional Material: 43 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 21 (1986), S. 205-213 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral phases ; Optimization of separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation and properties of chiral bonded phases with amino acid groups are described. These phases were used in non-polar eluents and in aqueous systems in the presence of Cu2+ ions in the ligand-exchange mode. The optimization of chiral resolution is demonstrated for both cases. With non-polar eluents similarity between bonded groups and solutes is required. The elution could be accelerated by non-protonic moderators. Ligand-exchange separation is influenced by the copper content of the eluent and the stationary phase, the organic moderator concentration, the pH and ionic strength of the buffer and by the temperature. Structural requirements of both the bonded groups and of the solutes for chiral separation are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Membrane-extraction disks ; On-line trace enrichment ; Polar pollutants ; Surface water
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An on-line trace-enrichment system, using a bifunctional membrane extraction-disk cartridge, has been combined with a column liquid chromatography separation for the simultaneous determination of basic, neutral and acidic pollutants in surface water. The enrichment device consisted of a specially constructed holder containing both C-18 and cation-exchange disks. The holder can contain up to 25 disks of 0.5 mm thickness and 4.6 mm diameter. Before trace enrichment of 20 ml of surface water (pH 3.0), calcium ions were removed from the sample by means of an oxalic acid precipitation. Desorption of the cartridge was at elevated temperature using reversed-phase gradient elution; detection was performed with a diode-array UV absorbance detector. The detection limits for the test compounds in surface water are typically 0.5–2 μg/l; the calibration graphs are linear from the lower limit of determination up to 50 μg/l.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Two-dimensional separation ; D- and L-amino acids ; Enantioseperation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A two-dimensional, column liquid chromatographic system is used for the determination of the D- and L-enantiomers of amino acids in biological samples. Separation of the amino acids is first on ion-exchange column by gradient elution with a sodium citratesodium chloride buffer. Enantioseparation is by subsequent injection of 3 μl heart-cuts of the individual amino acids onto a second column with a chiral crown ether stationary phase. Finally, fluorescence detection is after post-column labelling of the amino acids using ano-phthalaldehyde-2-mercaptoethanol reagent solution. The high separation power and selectivity of the system allow processing of complex samples with hardly any additional treatment and the determination of small quantities of D-amino acids in the presence of excess L-form. Applicability of the system is illustrated by the determination of D- and L-aspartate, serine, glutamate and alanine in various complex biological samples, such as protein hydrolysates, urine and biotechnological and food samples. Data are given on detectability, repeatability and linearity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0003-3146
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: An Folien (Dicke 100 pm) aus isotaktischem Polypropylen mit verschiedenen Antioxidansgehalten (0,0% bis 0,1%) wird die thermooxidative Alterunq mit der isothermen Langzeit-Differential-Thermo-Analyse (ILDTA) bis zu Temperaturen weit unter dem Kristallitschmelzbereich verfolqt und die Messwerte mit Ergebnissen aus dem Zeitstand-Zugversuch korreliert. Dabei zeigt sich, daß aus Messunqen mit der ILDTA bereits vor Einsetzen der autokatalytischen Zersetzunq sreaktion Ruckschlüsse auf die thermische Vorqeschichte der Proben und Aussagen auf das rnit einem Abfall der mechanischen Eigenschaften verbundene Ende der thermo-oxidativen Stabilität des Polymeren getroffen werden können.Weiters bietet die ILDTA die Moglichkeit, durch den direkten Zusamenhang zwischen Oxidationszeit und Antioxidansögehalt die örtliche Stabilisatorverteilung in Platten und in Folien zu bestimmen und damit Diffusionsvorqange zu verfolgen.
    Notes: Thermo-oxidative ageing processes were investigated in films (100 μm thick) made from isotactic polypropylene with different antioxidant concentrations between 0% and 0.1% using isothermal long-term differential thermal analysis (ILDTA). The end of the oven life of polypropylene coincided with the loss of mechanical properties which was confirmed by tensile tests at temperatures far below the crystallite melting range. Already prior to the beginning of autocatalytic decomposition, ILDTA experiments permits conclusions to be drawn on the thermal history of the specimens and statements made regarding the end of thermo-oxidative stability of the polymer, which is accompanied by a deterioration in the mechanical properties.In consequence of the correlation between oxidation time and antioxidant concentration the local antioxidant concentration in sheets or films can be measured by ILDTA. Thus, investigating the diffusion of an antioxidant in polypropylene using ILDTA is possible.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...