ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (180)
  • METEOROLOGY AND CLIMATOLOGY  (53)
  • EARTH RESOURCES AND REMOTE SENSING
  • Physics
  • 1985-1989  (270)
  • 1980-1984
  • 1989  (270)
Collection
Publisher
Years
  • 1985-1989  (270)
  • 1980-1984
Year
  • 1
    ISSN: 1040-7685
    Keywords: supercrirical fluid chromatography ; mass spectrometry ; capillary column ; inositol ; phosphate ; phytic acid ; silyl derivatives ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary supercritical fluid chromatography with flame ionization detection appears promising for the separation and detection of silylated inositol phosphates. Inositol triphosphate and phytic acid, following ion exchange to their fully protonated forms, were silylated in one step with the addition of 9 and 12 trimethylsilyl groups, respectively. The resulting derivatives are well behaved in open-tubular chromatography columns with methyl-silicone stationary phase when CO2 is used as the mobile phase. Both flow-splitting and directinjection methods were evaluated. The identities of the derivatives were confirmed by supercritical fluid chromatography-mass spectrometry using chemical ionization with both ammonia and isobutane, and using electron ionization - CO2 charge exchange.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-19
    Description: The history of minimum temperatures at 50 and 70 mb is examined from NMC, UK Met O and ECMWF analyses. MSU channel 24 data are similarly inspected. South Pole sonde data are used to calculate saturation humidity mixing ratio as a function of altitude and time throughout 1987. Saturation with respect to ice could be maintained for water mixing ratios of 3.5 ppmv for a period of about 80 days from mid-June to mid-September. Dehydration to mixing ratios of 1 ppmv or less was possible sporadically. Data from the ER-2 flights between 53 S and 72 S are used in conjunction with particle size measurements and air parcel trajectories to demonstrate the dehydration occurring over Antarctica. Water mixing ratios at the latitude of Punta Arens (53 S), in conjunction with tracer measurements and trajectory analysis, show that at potential temperatures from about 325 to 400 K, the dryness (less than 3 ppmv) had its origin over Antarctica rather than in the tropics. Water mixing ratios within the Antarctic vortex varied from 1.5 to 3.8 ppmv, with a strong isentropic gradient being evident in the region of high potential vorticity gradients.
    Keywords: METEOROLOGY AND CLIMATOLOGY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 94; 11317-11
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An increasing amount of evidence is accumulating to support the proposal that steroidogenesis can occur by a sesterterpene pathway as well as the cholesterol pathway. Key intermediates on the sesterterpene pathway are 23,24-dinor-5-cholen-3β-ol (guneribol) and some of its metabolites, e.g. 23,24-dinor-4-cholen-3-one (guneribone). It has been reported that these intermediates are biosynthesized and converted to steroid hormones by a range of endocrine tissues in vitro. Monitoring the pentafluorobenzyloxime derivatives by negative ion chemical ionization mass spectrometry in the electron capture mode provided evidence for the presence of guneribone in extracts of bovine testicular and human adrenal tumour tissue. Complementary evidence was obtained from gas chromatographic/tandem mass spectrometric data generated on a triple-quadrupole instrument by monitoring daughter ions (in the multiple ion detection, MID mode) of the molecular anion of derivatized guneribone in both standards and tissue extracts. The present findings that sesterterpene pathway intermediates are present as endogenous compounds in tissue extracts, together with the previously reported radiochemical data, give further support to the sesterterpene pathway hypothesis.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 18 (1989), S. 713-718 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Advanced glycation products have been investigated by parent ion spectroscopy, employing B2/E = constant linked scans of furoyl ions obtained from hydrolysed glycated albumin and polylysine mixtures, without any extraction procedures. Using such an instrumental approach, together with exact mass measurements and collision spectroscopy, the identification of 2-(2-furoyl)-4-hydroxyl-1H-imidazole and 2-(2-furoyl)-4-carboxy-1H-imidazole among the advanced glycation products has been achieved.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 18 (1989), S. 543-546 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A novel method is described for the analysis of 18O in urine by continuous flow-isotope ratio mass spectrometry (CF-IRMS), after sample equilibration with CO2. The method is shown to be fast, precise and accurate and therefore facilitates studies of total body water and water turnover in the clinical field. The method uses existing CF-IRMS instrumentation with minor hardware modification which does not compromise routine analysis of 13C and 15N. This method emphasizes the versatility of CF-IRMS and thus its economy for the biomedical research group using stable isotope tracers.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 18 (1989), S. 253-257 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Full-scan capillary zone electrophoresis/mass spectrometry and capillary zone electrophoresis/tandem mass spectrometry (CZE/MS/MS) are demonstrated for the determination of monosulfonated and polysulfonated azo dyes at the low picomole levels. Under selected ion monitoring conditions femtomole levels of the dyes are detectable. Ion evaporation via the ion spray liquid chromatography/mass spectrometry interface is a mild form of ionization exhibiting only deprotonated singly charged or poly-deprotonated multiply charged negative molecular ions for sulfonated azo dyes. CZE/MS/MS daughter ion scanning after collision-induced dissociation of the molecular species for all sulfonated azo dyes contained the sulfonate ion (m/z 80). The presence of three sulfonated azo dyes in a wastewater extract was confirmed by parent ion scanning for the sulfonate daughter ion (m/z 80).
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A liquid-solid extraction method suitable for rapid screening of sulfonated azo dyes in municipal wastewater has been developed. The dyes (Color Index Acid Yellow 23, Red 14 and Yellow 49) were separated on a short, reversedphase liquid chromatographic column with a water-methanol gradient containing 2 mM sulfuric acid. The column effluent was directed via a split-valve to an ion spray liquid chromatography/mass spectrometry (LC/MS) interface to an atmospheric pressure ionization mass spectrometer. The ion spray LC/MS system produced abundant [M - Na]- and [M - 2Na]2- ions according to the number of sulfonic acid substituents. Collision-induced dissociation of the parent ions for the dyes studied gave the SO3-. fragment common to sulfonated compounds plus additional daughter ion fragments characteristic of each dye. The dyes were quantified by monitoring from four to six different daughter ions of each dye. The relative abundances and the sum of the daughter ion current counts were used for confirmation and quantification with external standards. Recoveries of the dyes were in the range of 70-122%, and the relative standard deviation of replicate determinations was 5.4-12%. The method detection limit was three times higher for Acid Yellow 23 compared with the other two dyes, which could be detected down to 50 ppb in municipal wastewater.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Thermospray LC/MS methods with internal standardization were developed for the quantification of the antimalarial arteether and six of its metabolites at the 1-10 μg/ml level in liver microsome preparations without the use of solvent extraction. The thermospray mass spectra of arteether and most of its metabolites exhibited strong [M + NH4]+ and [M - OR]+ peaks arising from the molecular ion adduct and the loss of the alkoxy or hydroxy group of the side chain. In addition to the six metabolites for which authentic reference standards were available, three additional metabolites were detected. The major metabolites of arteether were found to be dihydroartemisinin, deoxydihydroartemisinin, 3-hydroxydeoxydihydroartemisinin, two isomers of hydroxyarteether, and 3-hydroxydeoxyarteether. Deoxyartheether was not found at significant concentrations in the microsome preparation.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An automated gas chromatographic/mass spectrometric assay is described for the antiepileptic drug valproic acid (VPA) and 14 of its metabolites in plasma or urine. Quantitative analysis of the parent drug and its biotransformation products was carried out with the aid of trimethylsilyl derivatives, and was performed by selected ion monitoring gas chromatography/mass spectrometry (normally of [M - CH3]+ species) using an HP 5790 mass selective detector (MSD) quadrupole mass spectrometer. The analysis was fully automated, in that simple injection, data acquisition, integration, quantification and report functions were carried out during unattended operation by an HP 59970C ChemStation™ computer system. The method exhibits good accuracy and high precision, with correlation coefficients greater than 0.990 for all standard curves. Replicate analyses of pooled plasma samples over a 4 month period exhibited an inter-day variation of less than 15% for the parent drug and ten of its metabolites. Moreover, the high dynamic range of the MSD instrument permitted quantification of VPA and minor metabolites thereof (e.g. the hepatotoxic terminal olefin, Δ4-VPA) at levels as disparate as 260 μg ml-1 (VPA) and 14 ng ml-1 (Δ4-VPA) in a single analysis. The high stability and sensitivity of the assay, combined with the fully automated features of the instrumentation, make the method ideally suited to expanded clinical studies and for the routine monitoring of potentially high-risk patients on VPA therapy.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 18 (1989), S. 844-850 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A liquid junction coupling has been developed to couple capillary zone electrophoresis (CZE) with ion spray mass spectrometry. The liquid junction was found to compensate for the different eluent flows required by the ion spray liquid chromatograph/mass spectrometer interface and the CZE column. The utility of the CZE/mass spectrometry union is demonstrated by its application to the separation of acid pesticides, sulfonated azo dyes and a tryptic digest of recombinant bovine somatotropin by CZE and detection by mass spectrometry and tandem mass spectrometry. Mass spectrometric detection was carried out in both positive and negative ion modes. Separation efficiencies are shown ranging from 50 000 to 300 000 theoretical plates with peak asymmetries of 1.2-1.8 for the components separated in the tryptic digest.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...