ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (51)
  • LIFE SCIENCES (GENERAL)  (51)
  • 1995-1999
  • 1980-1984  (102)
  • 1975-1979
  • 1982  (102)
Collection
Years
  • 1995-1999
  • 1980-1984  (102)
  • 1975-1979
Year
  • 1
    Publication Date: 2011-08-18
    Description: To test the possibility that spaceflight has a deleterious effect on bone mechanical properties, femur breaking strength by torsional loading in rats that had been flown for 19 days aboard Cosmos 936 was determined. The results showed that femurs from flight rats were less stiff than the flight controls, and failed under torsion at a lower torque and energy of absorption. The defect was corrected following space flight and could be prevented during space flight by centrifuging the rats at 1 x g. Altered bone geometry due to inhibition of bone formation at the periosteal surface provides the most likely explanation for the decrease in bone strength during spaceflight.
    Keywords: LIFE SCIENCES (GENERAL)
    Type: p. S-75
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-18
    Description: A diode-laser-based, ultrahigh resolution IR heterodyne spectrometer for laboratory and field use has been developed for operation between 7.5 and 8.5 microns. The local oscillator is a PbSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed-cycle cooler. The laser output frequency is controlled and stabilized using a high-precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. The system largely employs reflecting optics to minimize losses from internal reflection and absorption and to eliminate chromatic effects. Spectral analysis of the diode-laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the IR spectral regions over which useful heterodyne operation can be achieved. Observations have been made of atmospheric N2O, O3, and CH4 between 1170 and 1200/cm, using both a single-frequency swept IF channel and a 64-channel RF spectral line receiver with a total IF coverage of 1600 MHz.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 21; Jan. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-07-13
    Description: Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Instrumentation in astronomy IV; Fourth Conference; Mar 08, 1982 - Mar 10, 1982; Tucson, AZ
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: The effects of centrifugation on liver regrowth were examined by measuring mitotic activity. The results indicate that the increased gravity caused a delay in the onset of mitotic activity and a significant decrease in overall mitotic activity.
    Keywords: LIFE SCIENCES (GENERAL)
    Type: Space Gerontology; p 53-54
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-18
    Description: Addressing the question of whether the bone formed in space is unusual, the morphology of bone made at the tibial diaphysis of rats before, during, and after spaceflight is studied. Evidence of arrest lines in the bone formed in space is reported suggesting that bone formation ceases along portions of the periosteum during spaceflight. Visualized by microradiography, the arrest lines are shown to be less mineralized than the surrounding bone matrix. When viewed by scanning electron microscopy, it is seen that bone fractures more readily at the site of an arrest line. These observations are seen as suggesting that arrest lines are a zone of weakness and that their formation may result in decreased bone strength in spite of normalization of bone formation after flight. The occurrence, location, and morphology of arrest lines are seen as suggesting that they are a visible result of the phenomenon of arrested bone formation.
    Keywords: LIFE SCIENCES (GENERAL)
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-18
    Description: A hypokinetic rat model was used for elucidation of the mechanism of skeletal muscle wasting which occurs in weightlessness. Rats were suspended from a back-harness with the head tilted downward and the hind limbs totally unloaded. A progressive decrease in the size of the soleus muscle from suspended rats was observed as a function of time. The rate of protein degradation of the homogenates from the soleus muscles of suspended and control animals was not significantly different. The rate of cell-free protein synthesis was severely repressed in the atrophied muscle. An initial rise in the levels of plasma glucose and corticosterone was observed on the second day of suspension, but they subsequently returned to normal values.
    Keywords: LIFE SCIENCES (GENERAL)
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-18
    Description: The objective of this study was to determine whether a defect in transport of calcium in the duodenum was related to decreased bone formation in the suspended rat. Rats were suspended by the tail at a 40 deg angle for up to 15 days. Ca-45 was injected into the ligated duodenum in situ 15 minutes prior to sacrific. Blood, tibia, vertebra and humerus were obtained for total calcium and Ca-45 analyses. Intestinal calcium transport did not appear to be significantly altered by suspension. However, by 5 days of suspension a significant decrease in accumulation of Ca-45 into tibia and vertebra was observed. A trend of decreasing bone mineral and mass was established in tibia and vertebra by the fifth day of suspension. The humerus failed to demonstrate a significant weight decrease or change in Ca-45 accumulation after 15 days of suspension. Results from this simulated weightlessness model suggest that transport of calcium from intestine into bone is decreased within 5 days of suspension. This deficiency appears to be associated with a progressive decrease in total mass of non-weightbearing bones.
    Keywords: LIFE SCIENCES (GENERAL)
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-06-28
    Description: A digital optical torquemeter system designed for applications at high rotational speeds was fabricated and tested for zero stability at speeds up to 20,000 rpm. Data obtained in a spin rig and with simulated inputs demonstrate that the system is capable of measuring torque bar twist to within 0.03 degrees at speeds of 30,000 rpm. The optical system uses fiber optic bundles to transmit light to the torque bar and to silicon avalanche detectors. The system is microcomputer based and provides measurements of average torque and torque as a function of angular shaft position. The torquemeter requires no bearings or other contact between the rotating torque bar and the nonrotating optics, and tolerates movement of the torque bar as large as 1 mm relative to the optics.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-82914 , E-1189 , NAS 1.15:82914
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-28
    Description: The retarding ion mass spectrometer (RIMS) for Dynamics Explorer-1 is an instrument designed to measure the details of the thermal plasma distribution. It combines the ion temperature determining capability of the retarding potential analyzer with the compositional capabilities of the mass spectrometer and adds multiple sensor heads to sample all directions relative to the spacecraft ram direction. This manual provides a functional description of the RIMS, the instrument calibration, and a description of the commands which can be stored in the instrument logic to control its operation.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-82484 , NAS 1.15:82484
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-07-13
    Description: The obstacle block, developed as an alternative to the Preston tube for indirectly measuring skin friction on smooth surfaces in incompressible flows, is examined as a device for compressible flows as well. The block, which is congruent with a surface static pressure orifice, has a geometry which is easily specified and thus has a universal calibration. Data from two independent studies are used to establish such a calibration using 'wall' variables, valid for Mach numbers up to about 3. Various aspects concerning practical application of the device are examined, such as sensitivity to yaw and the minimum permissible axial spacing between blocks. Several examples showing the utility of the device are given.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA PAPER 82-0589 , In: Aerodynamic Testing Conference; Mar 22, 1982 - Mar 24, 1982; Williamsburg, VA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...