ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2020-08-25
    Description: An effective porosity is defined as the ratio of volume of interconnected pore space to total volume of a porous sample. It controls the magnitude of fluid flow and is a key parameter in the assessment of recoverable resources. However, its accurate measurement in tight formations is challenging, due to their complex pore structure and lithofacies heterogeneity. In this study, porosities of sixteen lacustrine shale samples from the second Member of the Kongdian Formation (Ek2) in the Cangdong Sag, Bohai Bay Basin were measured and compared using multiple methods and sample sizes to compare and contrast the effective porosity results. The methods included helium pycnometry (HP; cubes of 1 cm3 and grains at 500-841 μm), water immersion porosimetry (WIP; cubes), mercury intrusion porosimetry (MIP; cubes), and nuclear magnetic resonance (NMR; cubes). Finally, samples were completely sealed using paraffin for bulk density measurements to evaluate the extent of potential clay swelling in shale samples involving probing fluids. Results from the HP, WIP, and MIP methods for skeletal density, bulk density, and effective porosity with cubic samples were compared. While very similar skeletal densities were found for all three methods, a lower bulk density, and therefore lower porosity, from the MIP approach can be attributed to the experimental conditions (e.g., vacuum efficiency, applied pressure, wettability of water/helium vs. mercury) and the probable presence of pores with diameters larger than 50 μm not measurable by MIP. Furthermore, the HP porosity of granular samples with 500-841 μm grain sizes can be regarded as approaching the total porosity. The complicated relationship between WIP and NMR porosities may result from the heat-induced volatilization of moisture in pores during NMR tests, and countercurrent imbibition of water replacing the residual hydrocarbons during the saturation process for sample preparation in both tests. The swelling behavior of the lacustrine Ek2 shale with water is not significant because of the low content of expansive clay minerals. In summary, the WIP and HP methods are recommended for effective porosity measurement, whereas the NMR and MIP methods are invaluable for the measurement of pore-size distribution, with additional information on the effective porosity.
    Print ISSN: 1468-8115
    Electronic ISSN: 1468-8123
    Topics: Geosciences
    Published by Hindawi
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...