Publication Date:
2011-08-24
Description:
A preliminary investigation has been conducted on instrumented fasteners for use as sensors to measure the shear loads transmitted by individual fasteners installed in double-splice joints. Calibration and load verification tests were conducted for instrumented fasteners installed at three fastener torque levels. Results from calibration tests show that the shear strains obtained from the instrumented fasteners vary linearly with the applied load and that the instrumented fasteners can be effectively used to measure shear loads transmitted by individual fasteners installed in double-splice joints. Tests were also conducted with three instumented fasteners installed in a typical double-splice joint. The test results showed that the load distribution between individual fasteners is dependent on the location of the fastener in the joint and the fastener torque level.
Keywords:
INSTRUMENTATION AND PHOTOGRAPHY
Type:
Experimental Mechanics (ISSN 0014-4851); 34; 1; p. 16-22