    Publication Date: 2011-08-24
    Description: The 1992 global average total ozone, measured by the Total Ozone Mapping Spectrometer (TOMS) on the Nimbus-7 satellite, was 2 to 3 percent lower than any earlier year observed by TOMS (1979 to 1991). Ozone amounts were low in a wide range of latitudes in both the Northern and Southern Hemispheres, and the largest decreases were in the regions from 10 to 20 deg S and 10 to 60 deg N. Global ozone in 1992 is at least 1.5 percent lower than would be predicted by a statistical model that includes a linear trend and accounts for solar cycle variation and the quasi-biennial oscillation. These results are confirmed by comparisons with data from other ozone monitoring instruments: the SBUV/2 instrument on the NOAA-11 satellite, the TOMS instrument on the Russian Meteor-3 satellite, the World Standard Dobson Instrument 83, and a collection of 22 ground-based Dobson instruments.
    Keywords: GEOPHYSICS
    Type: Science (ISSN 0036-8075); 260; 5107; p. 523-526.